Thank you for selecting super quality dehumidifier. Please be sure to read this manual

carefully before using it. Keep the manual for future reference. CAUTIONS Please read the operating instructions carefully before using your dehumidifier for the first time. 1. Install the appliance on flat and hard place to avoid occurrence of vibration and noise. 2. Never immerse the appliance in water or other liquids. 3. Never operate the appliance if the cable or connector is damaged, or there is something abnormal may happen. 4. Disconnect the appliance from power supply when it is not in use, or before relocating or cleaning it. 5. Operate the appliance only at the voltage specified. 6. The appliance is for indoor use only, don’t use it for other purpose. 7. Do not put heavy objects on the appliance. 8. To prevent spilling, empty the water tank before restarting the appliance. 9. Do not put the unit close to heat-generating devices or near flammable and dangerous materials, don’t tip the appliance to any side as spilt water could damage the appliance. 10. Never insert any slim rod and hard object into the unit body to avoid occurrence of hazard or unit failure. 11. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Don’t try to repair, dismantle or remold such appliance, or it may make some damage. Even if the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.

When positioning the dehumidifier, ensure that it is placed on a level surface and that there

is a minimum of 10cm of space on either side of the unit to allow for efficient airflow. We do not recommend the use of an extension lead, so please try tot ensure that the unit is sufficiently close to a fixed main socket. If it is necessary to use an extension lead, please ensure the diameter of the wires of the cable is at least 1 mm2. When the dehumidifier is in operation, outside doors and windows should be closed when necessary for most efficient use. Allow at least 20cm of air space on all sides of the unit for good air circulation. Please the unit away from the clothes, dryer, heater or radiator. Make sure that there is no obstruction around the air inlet and the air outlet. The position of the air inlet and outlet is as below:

1. ON/OFF Switch 2. Power indicator light

4 3 7 8 9 11 6 5 10 3. Water full indicator 4. Control panel 1 2 5. Water tank 6. Power Cord 7. Filter 8. Carry Handle 9. Air outlet grille 10. Continuous drainage hole 11. Caster Operation - Plug the unit into a correct mains socket. - Press ON/OFF switch “(I)” once. The unit will start to work and the power indicator light will illuminate. - Press ON/OFF switch “(I)” again. The unit will stop and the power indicator light will go off. Note: 1. Do not use the machine when the temperature is over 35℃ or below 5℃. 2. When the unit has been turned off, please wait for at least 3 minutes before turn it on again. Fails to do this will damage the compressor.

While the water tank is full, the compressor will stop and the water full indicator light will

illuminate. To remove the water tank, pull it out carefully from the unit. After empting the water tank, place the tank back to the unit. Make sure it is properly positioned, in order for the water full indicator light to go out and your dehumidifier is operating. Please note, in case, the water tank has not been positioned well, the water full indicator light will still illuminate. CONTINUOUS DRAINAGE When the dehumidifier is operated at very high humidity levels, the water tank will require more frequent drainage. In this situation, it may be more convenient to set the unit up for continuous drainage with the following procedures: 1. Remove the water tank. Cut off the plastic cover located at drain hose outlet by a scissor. 2. Prepare the water tube (not included) with 16mm internal diameter and 1.5mm thickness. Connect to the continuous drainage hole. Ensure the water tube must be fixed securely. 3. Put the water tank back to main body. Ensure the water will always drain away freely and the tube will remain in right place & the water tank is in correct position. NOTE : In very cold weather conditions, precaution should be taken to prevent the water tube from freezing. If it is no longer to use the continuous drainage, please follow the below procedures : 1. Remove the water tank. 2. Disconnect the water tube from the hole. 3. Put the water tank back to main unit.

Always unplug the unit from the power supply before beginning cleaning to avoid

electric shocks. Housing - Use a soft, damp cloth to wipe the cabinet clean. Never use strong chemicals, oil-based products, detergents, chemically treated cloths or other cleaning solution. These could damage the cabinet. Filter - It is recommended to clean the air filter once every two weeks. -Remove the water tank and extract the filter holder. -Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filter. Rinse the filter frame thoroughly under running water.(Do not warmer than 40℃). - Dry thoroughly before replacing. - Do not expose the filter to sunlight. WARNING: Never operate the dehumidifier without the filters.

If not use the unit for an extended period of time. Please:

- Turn the unit off and unplug it from the mains. - Completely empty the water tank and wipe it clean. - Cover the unit and store where it will not receive direct sunlight. TROUBLE SHOOTING Never try to repair or dismantle the dehumidifier yourself. Incompetent repairs result in loss of warranty and can endanger the user and the property. Problem Possible Cause Solution Has the power cord been disconnected? Plug the power cord into the outlet. Is the tank full indication blinking? (the tank is full or in a wrong position) Empty the water in the drainage tank and then reposition the tank. The unit doesn't operate Is the temperature of the room above 35℃ or below 5℃? The protection device is activated and the unit cannot be started. Is the air filter clogged? Clean the air filter as instructions. The dehumidifying function doesn't work Is the intake duct or discharge duct obstructed? Remove the obstruction from the discharge duct or intake duct. No air is discharged Is the air filter clogged? Clean the air filter as instructions. Is the unit tilted or unsteady? Move the unit to a stable, sturdy location. Operation is noisy Is the air filter clogged? Clean the air filter as instructions.

(30℃ RH 80%)

L/24h 12 L/24h Air volume(max) m³/h 85 m³/h Refrigerant load g R134a/65g Compressor QX42H Thermostat ℃ 5℃-35℃ Recommended room size m2 Up to 18 m2 Water tank L 1.5 L Dimensions(W*H*D) mm 325*150*495mm Weight Kg 8.5Kg WASTE ELECTRICAL PRODUCTS SHOULD NOT BE DISPOSED OF WITH HOUSEHOLD WASTE.PLEASE RECYCLE WHERE FACILITIES EXIST CHECK WITH YOUR LOCAL AUTHORITY FOR RECYCLING ADVICE.

CONNECTION TO POWER

ƒ Before connecting, check that the voltage indicated on the appliance (bottom of the appliance) corresponds with the main voltage in your home. If this is not the case, consult your dealer and do not use. ƒ This appliance may be fitted with a non-rewirable plug. If you need to change the fuse in a non-rewirable plug, the fuse cover must be refitted. If the fuse cover is lost or damaged, the plug must not be used until a replacement is obtained (available from the appliance manufacturer). ƒ If the plug has to be changed because it is not suitable for your socket, or becomes damaged, it should be cut off and appropriate plug fitted following the wiring instructions. The plug removed must be disposed of safely as insertion into a mains socket is likely to cause an electrical hazard. ƒ This unit must be earthed. This equipment must be disconnected from the mains when not in use. Do not allow this unit to be exposed to rain or moisture. For your own safety read the following instructions carefully before attempting to connect this unit to the mains. You should only plug the appliance into a 230V-240V AC, 50Hz supply. Connecting it to other power sources may damage the appliance. The wires in this mains lead are coloured in accordance with the following code: BLUE = NEUTRAL BROWN = LIVE GREEN + YELLOW = EARTH IMPORTANT The colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: Caution To prevent electric shock disconnect from the mains before removing the cover ƒ The blue wire must be connected to the terminal marked with the letter N or coloured black. ƒ The brown wire must be connected to the terminal marked with the letter L or coloured red. ƒ The green and yellow wire must be connecting to the terminal marked with the letter E or the earth symbol. ( ). If a 13 Amp (BS1363) fused plug is used it must be fitted with a 13A fuse conforming to BS1362 and be ASTA approved. If in doubt contact a qualified electrician.