CYP CMPRO-U4H4CVPL Operation Manual

Specifications

Brand: CYP
Category: Matrix Switcher
Model: CMPRO-U4H4CVPL (Operation Manual)
File Type: PDF
File Size: —
Pages: 20

Read Online

Read the CYP CMPRO-U4H4CVPL Operation Manual online using the built-in PDF viewer.

Text of the manual

The information in this manual has been carefully checked and

is believed to be accurate. Cypress Technology assumes no responsibility for any infringements of patents or other rights of third parties which may result from its use. Cypress Technology assumes no responsibility for any inaccuracies that may be contained in this document. Cypress also makes no commitment to update or to keep current the information contained in this document. Cypress Technology reserves the right to make improvements to this document and/or product at any time and without notice. COPYRIGHT NOTICE No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or any of its part translated into any language or computer file, in any form or by any means— electronic, mechanical, magnetic, optical, chemical, manual, or otherwise—without express written permission and consent from Cypress Technology. © Copyright 2014 by Cypress Technology. All Rights Reserved. Version 1.0 April 2014 TRADEMARK ACKNOWLEDGMENTS All products or service names mentioned in this document may be trademarks of the companies with which they are associated.

Please read all instructions before attempting to unpack, install or

operate this equipment and before connecting the power supply. Please keep the following in mind as you unpack and install this equipment: • Always follow basic safety precautions to reduce the risk of fire, electrical shock and injury to persons. • To prevent fire or shock hazard, do not expose the unit to rain, moisture or install this product near water. • Never spill liquid of any kind on or into this product. • Never push an object of any kind into this product through any openings or empty slots in the unit, as you may damage parts inside the unit. • Do not attach the power supply cabling to building surfaces. • Use only the supplied power supply unit (PSU). Do not use the PSU if it is damaged. • Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk on it. • To protect the unit from overheating, do not block any vents or openings in the unit housing that provide ventilation and allow for sufficient space for air to circulate around the unit. REVISION HISTORY VERSION NO. DATE DD/MM/YY SUMMARY OF CHANGE RDV1 15/05/14 Preliminary Release RDV2 18/09/14 Add RS-232 Command

3. Package Contents��������������������������������1

4. System Requirements����������������������������2 5. Features��������������������������������������������������2 6. Operation Controls and Functions�������3 6.1 Front Panel����������������������������������������3 6.2 Rear Panel�����������������������������������������4 6.3 Remote Control��������������������������������5 6.4 IR Cable Pin Assignment�����������������5 6.5 RS-232 Pin Assignment���������������������6 6.6 RS-232 and Telnet Commands�������7 6.7 Telnet Control�����������������������������������9 6.8 Web GUI Control����������������������������11 7. Connection Diagram��������������������������12 8. Specifications��������������������������������������13 8.1 CAT5e/6/7 Cable Specification���13 8.2 CAT5e/6/7 Cable Specification���14 9. Acronyms���������������������������������������������15

The 4K2K 4 by 4 HDMI Matrix over CAT5e/6/7 supports the transmission

of video (resolutions up to 4K2K Full HD), multi-channel digital audio and control via IR, RS-232, Telnet or Web GUI from four high definition sources to four outputs over a single CAT5e/6/7 cable (up to 60m) for each output. It supports high resolution digital audio formats such as LPCM 7.1CH, Dolby TrueHD, Dolby Digital Plus and DTS-HD Master Audio as well as 3D content that can be displayed when connecting a 3D TV and 3D source. 2. APPLICATIONS •  HDMI Matrix System •  Video/TV wall display and control •  Security surveillance and control •  Commercial advertising, display and control •  University lecture hall, display and control •  Retail sales and demonstration 3. PACKAGE CONTENTS •  4K2K 4×4 HDMI Matrix over CAT5e/6/7 •  1×IR Extender •  1×IR Blaster •  1×24 V/3.75A DC Power Adaptor •  1×Power Cord •  1×IR Remote Control with battery •  1x Right and Left Ear Rack Sets •  Operation Manual

4. SYSTEM REQUIREMENTS

•  HDMI equipped source devices, connect with HDMI cables or DVI equipped source, connect with DVI to HDMI cables •  HDMI equipped displays (TVs or monitors) or HDMI equipped AV receivers, connect with HDMI cables •  Industry standard CAT5e/6/7 cables •  HDBaseT™ Receivers 5. FEATURES •  HDMI, HDCP1.1 and DVI compliant •  Supports HDMI 3D features •  Supports resolutions VGA~WUXGA and 4K2K @50/60(YUV_420) dependent upon the output display’s EDID settings •  Supports distances up to 60 meters through CAT5e/6/7 cables •  Supports 3D signal display dependent upon the output display EDID settings •  Supports HDMI input/output up to 10 meters at 8-bit/12-bit resolution or 5 meters at 4K2K resolution •  Supports bi-directional IR from input and output locations or 5 meters at 4K2K resolution •  Supports RS-232, remote control, on-panel control and IP Control (Telnet & Web GUI) •  1U size design •  Supports external and internal EDID settings •  Supports LPCM 7.1CH, Dolby TrueHD, Dolby Digital Plus and DTS-HD Master Audio transmission Note: Do not connect the LAN/CONTROL port to CAT outputs of this device, doing so may tigger the device to shoot down.

6. OPERATION CONTROLS AND FUNCTIONS

6.1 Front Panel 4X4 HDMI MATRIX OVER CAT5e/6/7 POWER LOCK MENU A/1 B/2 C/3 D/4 OUT IN 6 1 2 3 4 5 1 LCM: Displays the setting information of each input and output setting. 2 IR: IR Receiver window (accepts the remote control signal of this device only). 3 POWER: Press this button to power the device on/off. The LED will illuminate green when the power is on, red when it is in 'Standby' mode. 4 LOCK: Press this button to lock all the buttons on the panel; press again to unlock. The LED will illuminate when locked. 5 MENU: Press this button to access the LCM menu system, from here EDID settings can be managed and IP system settings are displayed. 6 A~D/1~4 and OUT/IN: Press the OUT or IN button to select the output or input mode and then press the required number button to make the selection accordingly. For example, if outputs A~B need to be set to input 1 and outputs C~D need to be set to input 2, then the following sequence of button presses need to be performed: Press: OUTABIN1MENU, and then press: OUTCDIN2MENU. Note: If the MENU button is not pressed the selection will not be changed.

6.2 Rear Panel

IR OUT IR IN ALL RS232 IP CONTROL SERVICE 1 IR IN IR OUT 2 IR IN IR OUT 3 IR IN IR OUT 4 IR IN IR OUT HDMI IN 1 HDMI IN 2 HDMI IN 3 HDMI IN 4 DC 24V 1 2 3 4 V+ GND GND GND V+ CAT5e/6/7 OUT CAT5e/6/7 OUT CAT5e/6/7 OUT C B A D CAT5e/6/7 OUT 2 3 4 4 4 4 9 10 7 1 8 5 6 5 6 5 6 5 6 1 RS-232: Connect to a PC or control system with D-Sub 9-pin cable for the transmission of RS-232 commands. 2 IP & CONTROL: This port is the link for Telnet or Web GUI controls, connect to an active Ethernet link with an RJ45 terminated cable (for further details, please refer to section 6.8 & 6.9). 3 SERVICE: Manufacturer use only. 4 CAT5e/6/7 OUT A~D: Connect from these CAT outputs to the CAT input port of the receiver units with a single CAT5e/6/7 cable for HDMI Audio/Video and IR/RS-232 control signal transmission. 5 IR IN 1~4: Connect to the IR extenders for IR signal reception. Ensure that the remote being used is within the direct line-of-sight of the IR extender for it will send out the IR signal to the selected receiver's IR OUT. 6 IR OUT 1~4: Connect to the IR blasters for IR signal transmission. Place the IR blaster in direct line-of-sight of the equipment to be controlled for it will blaster out the IR signal received from the receiver side choosen by input selection. 7 HDMI IN 1~4: Connect to the HDMI input source devices such as a DVD player or a Set-top Box with HDMI cable or DVI to HDMI cable. 8 ALL IR OUT: Connect to the IR blaster for IR signal transmission to the source side. Place the IR blaster in direct line-of-sight of the equipment to be controlled for it will blaster out all signal received from the IR IN at the receiver sides. 9 ALL IR IN: Connect to the IR extender for IR signal reception. Ensure that remote being used is within the direct line-of-sight of the IR extender for it will send out the signal to all receiver's IR OUT. 10 DC 24V: Plug the 24 V DC power supply into the unit and connect the adaptor to an AC outlet. Warning: Please do not connect the CAT5e/6/7 cable into the receiver's LAN port.

6.3 Remote Control

1 POWER: Press this button to switch on the device or set it to standby mode. 2 IN: Input ports selection 1~4. 3 OUT: Output ports selection A~D. 6.4 IR Cable Pin Assignment 3 1 3 1 2 2 Power IR Blaster Signal NC IR Signal Power Grounding IR Extender IR Blaster 1 2 3 1 A B 2 C 3 4 D CR-121 IN OUT

6.5 RS-232 Pin Assignment

CMPRO-U4H4CVPL Remote Control Console PIN Assignment PIN Assignment 1 NC 1 NC 2 Tx 2 Rx 3 Rx 3 Tx 4 NC 4 NC 5 GND 5 GND 6 NC 6 NC 7 NC 7 NC 8 NC 8 NC 9 NC 9 NC Baud Rate: 19200 bps Data Bit: 8-bit Parity: None Stop Bit: 1-bit Flow Control: None

6.6 RS-232 and Telnet Commands

Command Description help Dipslay all available commands A1~A4 Switch Output A to 1~4 B1~B4 Switch Output B to 1~4 C1~C4 Switch Output C to 1~4 D1~D4 Switch Output D to 1~4 AB…1~AB…4 Switch Output ABCD to 1~4 at the same time SETIP Setting IP. SubNet. GateWay RSTIP IP configuration was reset to factory defaults IPCONFIG Display the current IP config P0 Power Off P1 Power On STORE 01~04 Store current I/O position (01~04) PRESET 01~04 Recall the store I/O Position (01~04) SHOW 01~04 Show current port's I/O position (01~04) NAME N1 N2 Name the stored port N1(01~04) no more than 8 charactors, N2 (ABCDEFGH) I1~I4 Switch all the output to 1~4 ST Display the current matrix state and firmware version RS System Reset to A1, B1, C2, D2, E3, F3, G4, H4 EM Setting EDID MODE. 1-STD 2-TV. ? Display all available commands QUIT Exit (Telnet only)

Display baud rate setting 1~6

1: 9600bps 2: 14400bps 3: 19200bps 4: 38400bps 5: 57600bps 6: 115200bps UARTBAUD1 Set output A’s baud rate from 1~6 UARTBAUD2 Set output B’s baud rate from 1~6 UARTBAUD3 Set output C’s baud rate from 1~6 UARTBAUD4 Set output D’s baud rate from 1~6 UARTSW? Display output’s UART status UARTSW0 Switch to MCU. Allowing Receivers to send commands to Matrix. UARTSW1 Switch to output A and allow Matrix to send commands to Receiver’s connected device. UARTSW2 Switch to output B and allow Matrix to send commands to Receiver’s connected device. UARTSW3 Switch to output C and allow Matrix to send commands to Receiver’s connected device. UARTSW4 Switch to output D and allow Matrix to send commands to Receiver’s connected device. Quit Exit (for telnet only) Note: 1. All the command will be not executed unless followed with a carriage return. All letters are case-insensitive. 2. Commands are under RS-232 control only. 3. EDID STD@1080p/2CH, EDID TV@Output A.

6.7 Telnet Control

Before attempting to use the telnet control, please ensure that both the Matrix (via the 'LAN /CONTROL' port) and the PC/Laptop are connected to the active networks. To access the telnet control in Windows 7, click on the 'Start' menu and type "cmd" in the Search field then press enter. Under Windows XP go to the 'Start' menu and click on "Run", type "cmd" with then press enter. Under Mac OS X, go to Go→Applications→Utilities→Terminal See below for reference.

Once in the command line interface (CLI) type "telnet", then the IP

address of the unit and "23", then hit enter. Note: The IP address of the Matrix can be displayed on the device's LCM monitor by pressing the Menu button twice. This will bring us into the device which we wish to control. Type "HELP" to list the available commands. Type “IPCONFIG” To show all IP configurations. To reset the IP, type “RSTIP” and to use a set static IP, type ”SETIP” (For a full list of commands, see Section 6.7). Note: Any commands will not be executed unless followed by a carriage return. Commands are case-insensitive. If the IP is changed then the IP Address required for Telnet access will also change accordingly.

6.8 Web GUI Control

On a PC/Laptop that is connected to the same active network as the Matrix, open a web browser and type device's IP address on the web address entry bar. The browser will display the device's status, control and User setting pages. Click on the 'Control' tab to control power, input/output ports, EDID and reset mode. Clicking on the 'User Setting' tab allows you to reset the IP configuration. The system will ask for a reboot of the device every time any of the settings are changed. The IP address needed to access the Web GUI control will also need to be changed accordingly on the web address entry bar.

7. CONNECTION DIAGRAM

IR OUT IR IN ALL RS232 IP CONTROL SERVICE 1 IR IN IR OUT 2 IR IN IR OUT 3 IR IN IR OUT 4 IR IN IR OUT HDMI IN 1 HDMI IN 2 HDMI IN 3 HDMI IN 4 DC 24V 1 2 3 4 V+ GND GND GND V+ CAT5e/6/7 OUT CAT5e/6/7 OUT CAT5e/6/7 OUT C B A D CAT5e/6/7 OUT IR EMITTER 1.5m 60° IR RECEIVER 7m 3m 3m 60° m ZONE A RX ZONE C RX ZONE D RX 1 2 3 4 ZONE B RX 2 1 3 4 Blu-ray Player RS-232 Equipped PC or Control System CAT5e/6 Output Power Supply Network Router IR In All IR Out All Media Server Satellite Receiver Set-top Box HDMI Input IR In/ Out

340 MHz/10.2 Gbps

Input Ports 4×HDMI, 5×IR Extender, 1×RS-232, 1×RJ- 45(Control), 1×Mini USB Type B (For firmware updated only) Output Ports 4×CAT5e/6/7, 5×IR Blaster ESD Protection Human-body Model: ± 8kV (Air-gap discharge) ± 4kV (Contact discharge) Power Supply 24 V/3.75 A DC (US/EU standards, CE/ FCC/UL certified) Dimensions 436 mm (W)×249mm (D)×44 mm (H)/ Jacks Excluded 436 mm (W)×256.2mm (D)×48 mm (H)/ Jacks Included Weight 3352 g Chassis Material Metal Silkscreen Color Black Operating Temperature 0 ºC~40 ºC/32 ºF~104 ºF Storage Temperature −20 ºC~60 ºC/−4 ºF~140 ºF Relative Humidity 20~90 % RH (non-condensing) Power Consumption 66W 8.1 CAT5e/6/7 Cable Specification Cable Type Range Pixel clock rate Video Data Rate Supported Video CAT5e/6/ CAT 7 60 m <=225 MHz <=5.3 Gbps (HD Video) Up to 1080p, 60 Hz, 36 bits 3D(data rates lower than 5.3 Gbps or below 225 MHz TMDS clock).

8.2 CAT5e/6/7 Cable Specification

INPUT OUTPUT 640x480@60/72/75/85 V V 800x600@56/60/72/75/85 V V 1024x768@60/70/75/85 V V 1280x720@60 V V 1280x1024@60 V V 1600x1200@60 V V 1920x1200@60RB V V 3840x2160p@24/25/30 V V 4096x2160p@24 V V 4096x2160p@50/60(YUV_420) V V 480I/576I V V 480P/576P V V 720P@50/60 V V 1080I@50/60 V V 1080P@50/60 V V 1080P@24/25/30 V V

Home page: http://www.cypress.com.tw

CYPRESS TECHNOLOGY CO., LTD MPM-CMPROU4H4CVPL 9. ACRONYMS ACRONYM COMPLETE TERM CLI Command Line Interface DTS Digital Theater System DVI Digital Visual Interface EDID Extended Display Identification Data GUI Graphical User Interface HDCP High-bandwidth Digital Content Protection HDMI High-Definition Multimedia Interface HDTV High-Definition Television LCM Liquid Crystal Module USB Universal Serial Bus VGA Video Graphics Array WUXGA Widescreen Ultra Extended Graphics Array