CYP CMSDI-164 Operation Manual

Specifications

Brand: CYP
Category: Matrix Switcher
Model: CMSDI-164 (Operation Manual)
File Type: PDF
File Size: —
Pages: 16

Read Online

Read the CYP CMSDI-164 Operation Manual online using the built-in PDF viewer.

Text of the manual

16 by 4 / 12 by 4 / 8 by 4 / 4 by 4 3G-SDI Matrix

Operation Manual Operation Manual

The information in this manual has been carefully checked and

is believed to be accurate. Cypress Technology assumes no responsibility for any infringements of patents or other rights of third parties which may result from its use. Cypress Technology assumes no responsibility for any inaccuracies that may be contained in this document. Cypress also makes no commitment to update or to keep current the information contained in this document. Cypress Technology reserves the right to make improvements to this document and/or product at any time and without notice. COPYRIGHT NOTICE No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or any of its part translated into any language or computer file, in any form or by any means— electronic, mechanical, magnetic, optical, chemical, manual, or otherwise—without express written permission and consent from Cypress Technology. © Copyright 2011 by Cypress Technology. All Rights Reserved. Version 1.1 August 2011 TRADEMARK ACKNOWLEDGMENTS All products or service names mentioned in this document may be trademarks of the companies with which they are associated.

Please read all instructions before attempting to unpack, install or

operate this equipment and before connecting the power supply. Please keep the following in mind as you unpack and install this equipment: • Always follow basic safety precautions to reduce the risk of fire, electrical shock and injury to persons. • To prevent fire or shock hazard, do not expose the unit to rain, moisture or install this product near water. • Never spill liquid of any kind on or into this product. • Never push an object of any kind into this product through any openings or empty slots in the unit, as you may damage parts inside the unit. • Do not attach the power supply cabling to building surfaces. • Use only the supplied power supply unit (PSU). Do not use the PSU if it is damaged. • Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk on it. • To protect the unit from overheating, do not block any vents or openings in the unit housing that provide ventilation and allow for sufficient space for air to circulate around the unit. REVISION HISTORY VERSION NO. DATE DD/MM/YY SUMMARY OF CHANGE VS1 23/02/12 First release VS2 17/07/12 SDI standards updated VR3 08/08/12 RS-232 command

3. Package Contents��������������������������������������1

4. System Requirements����������������������������������1 5. Features��������������������������������������������������������2 6. Operation Controls and Functions�������������3 6.1 Front Panel����������������������������������������������3 6.2 Rear Panel�����������������������������������������������4 6.3 Remote Control��������������������������������������5 6.4 RS-232 Pin Assignment���������������������������6 6.5 RS-232 Commands���������������������������������6 7. Connection Diagram����������������������������������7 8. Specifications����������������������������������������������8 9. Acronyms�����������������������������������������������������9

The 3G-SDI Matrix series allows SD-SDI, HD-SDI and 3G-SDI signals

to be shown on SDI displays while ensuring high bit-rates of 2.970 Gbps to give you fast signal transmission without signal loss. For professionals, this means that it is now easier to switch multiple 3G-SDI signals and split display of them on up to four SDI-equipped displays simultaneously. Additionally, these units can be controlled with the supplied IR remote, the front panel keys or RS-232 control functions. 2. APPLICATIONS •  Video broadcasting switching display •  Professional video program display •  Film studios program monitoring •  Video program switching display 3. PACKAGE CONTENTS •  16 by 4/12 by 4/8 by 4/4 by 4 3G-SDI Matrix •  Remote Control (CR-101) •  5  V/2.6  A DC Power Adaptor •  Operation Manual 4. SYSTEM REQUIREMENTS Source devices with SDI (SD/HD/3G) output, display devices with SDI Input and connected with SDI cables.

•  3G-SDI input sources can be selected and split or switched to

four 3G-SDI displays simultaneously •  Operation at 2.970 Gbps, 2.970/1.001 Gbps, 1.485 Gbps, 1.485/1.001 Gbps and 270 Mbps •  Supports SMPTE 425M (Level A and Level B), SMPTE 424M, SMPTE 292M, SMPTE 259M-C •  Connect using other units to extend your signal over long distances •  Signal is equalized and re-clocked •  Supports signal input and output distances of up to 300 meters for SD signals, 200 meters for HD signals and 100 meters for 3G signals Note: Tested with Belden 1694A cable. Operating distances may vary if used with another type of cable.

6. OPERATION CONTROLS AND FUNCTIONS

6.1 Front Panel OUTPUT ENTER - INPUT + 16X4 3G SDI Matrix CMSDI-164 LOCK POWER LOCK 1 2 3 4 5 6 7 1 LCD Monitor: This LCD monitor displays the configuration of the input and output selections. The upper line displays the outputs A, B, C, & D. The lower line displays each output’s selected input. 2 IR Receiver: Receives the IR signal from the remote control included in the package. 3 OUTPUT Button: Press this button to select the output A~D the cursor will skip to the lower line of the LCD monitor then, select an input for highlighted output. 4 INPUT −/+ Button: Press − or + button to select the input sources from 1~16, press ENTER to confirm the selection. Note: Depending on different models, the selectable input will be displayed on the LCD monitor. 5 Lock Button: Press both the '−' and 'ENTER' buttons together to lock all the function keys on the panel. To unlock, press both buttons again. 6 ENTER Button: Press this button to confirm the selection. Press both the 'ENTER' key and '–' key together to lock all the keys on panel. To unlock, press both the 'ENTER' key and '–' key together again to release the locking system. 7 LOCK LED: This LED will illuminate in green when the key lock is active. 8 POWER LED: This LED will illuminate green when the device is switched ON. When in standby mode (Press the power key on the remote control) the LED will turn red.

6.2 Rear Panel

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A B C D RS-232 DC 5V SDI INPUT SDI OUTPUT 1 2 3 4 1 DC 5V: Plug the 5V DC power supply into the unit and connect the adaptor to AC wall outlet. 2 RS-232: Connect to a PC or laptop (with D-Sub 9 pin female cable) to control the device via RS-232 commands.. 3 SDI INPUT: Connect to the SDI source equipment such as video camera or SDI player. The amount of input slots will depend on the model. MODEL INPUTS OUTPUTS CMSDI-164 16 4 CMSDI-124 12 4 CMSDI-84 8 4 CMSDI-44 4 4 4 SDI OUTPUT: Connect to the SDI displays with an SDI cables for displaying the output. It can also be connected to another SDI converter/extender to extend the signal.

6.3 Remote Control

1 3 2 4 1 POWER: Press the button to power the unit on/off. 2 OUTPUT: Press an output port from A~D first then select an input number and press enter to confirm the selection. 3 INPUT: Press the number keys to select the desired input source from 01~16 after selecting the output then press enter to confirm the selection. Note: selectable inputs are dependant on the controlling device. 4 ENTER: Press this button to confirm each input/output selection.

6.4 RS-232 Pin Assignment

Pins definition of modem cable CMSDI-44/84/124/164 Remote Controller PIN Definition PIN Definition 1 NC 1 NC 2 TxD 2 RxD 3 RxD 3 TxD 4 NC 4 NC 5 GND 5 GND 6 NC 6 NC 7 NC 7 NC 8 NC 8 NC 9 NC 9 NC Baud Rate: 19200 bps Data bit: 8-bit Parity: None Stop bit: 1-bit Flow Control: None 6.5 RS-232 Commands Command Description poweron Power ON poweroff Power OFF portx xx x= a~d output, xx=01~16 input For example, when SDI output A needs to be SDI input 2, the command would be porta 02. Note: All the RS-232 command will be not executed unless followed with a carriage return. Commands are not case-sensitive.

7. CONNECTION DIAGRAM

SDI DV Camera x16 SDI Monitor x 4 Note: The above diagram shows the 16 by 4 SDI matrix (CMSDI-164). 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A B C D RS-232 DC 5V SDI INPUT SDI OUTPUT

425M Level A & B, 424M, 292M, 259M-C

SDI Transmission Rates 2.970 Gbps and 2.970/1.001 Gbps, 1.485Gbps, 1.485/1.001 Gbps and 270 Mbps Input Ports 16/8/4×BNC (SD/HD/3G-SDI) Output Ports 4×BNC (SD/HD/3G-SDI) SDI Timing Support SD-SDI: SMPTE 259M-C, 270 Mbit/s HD-SDI: SMPTE 292M, 1.485 & 1.485/1.001 Gbit/s 3G-SDI: SMPTE 424M/425M-AB, 2.970 & 2.970/1.001 Gbit/s ESD Protection Human-body Model: ± 8 kV (air-gap discharge) ± 4 kV (contact discharge) SDI Cable Distance 3G-SDI up to 100m (BELDEN 1694A) HD-SDI up to 200m (BELDEN 1694A) SD-SDI up to 300m (BELDEN 1694A) Power Supply 5 V DC/2.6 A (US/EU standards, CE/FCC/ UL certified) Dimensions 436 mm (W)×132 mm (D)×93mm (H) Weight 2476g (164), 2380g (84), 2340g (44) Chassis Material Metal Silkscreen Color Black Operating Temperature 0 ˚C~40 ˚C/32 ˚F~104 ˚F Storage Temperature −20 ˚C~60 ˚C/−4 ˚F~104 ˚F Relative Humidity 20~90 % RH (non-condensing) Power Consumption 8.5 W (164), 6.5 W(84), 5.5 W (44)

Bandwidth 2.97Gbit/s ≈ 3G

BNC Bayonet Neill-Concelman SDI Serial Digital Interface

Other Matrix Switcher Manuals