D-Link DES-3528 - xStack Switch - Stackable Operation & User’s Manual
Text of the manual
Product Model: xStack® DES-3528/DES-3552 Series
Layer 2 Managed Stackable Fast Ethernet Switch
Release 2.0
©Copyright 2009. All rights reserved.
_________________________________________________________________________________
Information in this document is subject to change without notice.
© 2009 D-Link Corporation. All rights reserved.
Reproduction in any manner whatsoever without the written permission of D-Link Corporation is strictly forbidden.
Trademarks used in this text: D-Link and the D-LINK logo are trademarks of D-Link Corporation; Microsoft and Windows are registered trademarks
of Microsoft Corporation.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products.
D-Link Corporation disclaims any proprietary interest in trademarks and trade names other than its own.
September 2009 P/N 651ES3500055G
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
ii
Table of Contents
Web-based Switch Configuration ............................................................................................... 11
Introduction ................................................................................................................................................................. 11
Login to Web Manager ............................................................................................................................................................. 11
Web-based User Interface ....................................................................................................................................................... 12
Web Pages .............................................................................................................................................................................. 13
Configuration ............................................................................................................................... 14
Device Information ...................................................................................................................................................... 15
System Information ..................................................................................................................................................... 15
Serial Port Settings ..................................................................................................................................................... 16
IP Address .................................................................................................................................................................. 16
Port Configuration ....................................................................................................................................................... 19
Port Settings ............................................................................................................................................................................ 19
Port Description ....................................................................................................................................................................... 21
Port Error Disabled .................................................................................................................................................................. 21
Static ARP Settings .................................................................................................................................................... 22
User Accounts ............................................................................................................................................................ 23
System Log Configuration .......................................................................................................................................... 24
System Log Settings ................................................................................................................................................................ 24
System Log Server .................................................................................................................................................................. 25
System Severity Settings ............................................................................................................................................ 26
DHCP Relay................................................................................................................................................................ 27
DHCP Relay Global Settings ................................................................................................................................................... 27
DHCP Relay Interface Settings ................................................................................................................................................ 30
DHCP Relay Option 60 Default Settings .................................................................................................................................. 30
DHCP Relay Option 60 Settings .............................................................................................................................................. 31
DHCP Relay Option 61 Default Settings .................................................................................................................................. 32
DHCP Relay Option 61 Settings .............................................................................................................................................. 32
DHCP Local Relay Settings ........................................................................................................................................ 33
DHCP Auto Configuration Settings ............................................................................................................................. 33
MAC Address Aging Time .......................................................................................................................................... 34
Web Settings .............................................................................................................................................................. 34
Telnet Settings ............................................................................................................................................................ 34
Password Encryption .................................................................................................................................................. 34
Clipaging Settings ....................................................................................................................................................... 35
Firmware Information .................................................................................................................................................. 35
Dual Configuration Settings ........................................................................................................................................ 36
PPPoE Circuit ID Insertion Settings ........................................................................................................................... 37
Ping Test ..................................................................................................................................................................... 37
SNTP Settings ............................................................................................................................................................ 38
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
iii
Time Settings ........................................................................................................................................................................... 38
TimeZone Settings ................................................................................................................................................................... 39
MAC Notification Settings ........................................................................................................................................... 40
MAC Notification Global Settings ............................................................................................................................................. 40
MAC Notification Port Settings ................................................................................................................................................. 41
PoE ............................................................................................................................................................................. 42
PoE System Settings ............................................................................................................................................................... 43
PoE Port Settings ..................................................................................................................................................................... 44
SNMP Settings ........................................................................................................................................................... 45
SNMP Global Settings ............................................................................................................................................................. 46
SNMP View Table .................................................................................................................................................................... 46
SNMP Group Table .................................................................................................................................................................. 47
SNMP User Table .................................................................................................................................................................... 48
SNMP Community Table.......................................................................................................................................................... 49
SNMP Host Table .................................................................................................................................................................... 50
SNMP Engine ID ...................................................................................................................................................................... 50
SNMP Trap Configuration ........................................................................................................................................................ 51
sFlow ........................................................................................................................................................................... 51
sFlow Global State Settings ..................................................................................................................................................... 51
sFlow Analyzer Server Settings ............................................................................................................................................... 52
sFlow Flow Sampler Settings ................................................................................................................................................... 52
sFlow Counter Poller Settings .................................................................................................................................................. 53
Stacking ...................................................................................................................................................................... 54
Stacking Mode Settings ........................................................................................................................................................... 56
Time Range Settings .................................................................................................................................................. 56
Single IP Management ............................................................................................................................................... 57
Single IP Settings ..................................................................................................................................................................... 58
Topology .................................................................................................................................................................................. 59
Tool Tips .................................................................................................................................................................................. 62
Right-Click................................................................................................................................................................................ 63
Menu Bar ................................................................................................................................................................................. 65
Firmware Upgrade ................................................................................................................................................................... 66
Configuration File Backup/Restore .......................................................................................................................................... 66
Upload Log File ........................................................................................................................................................................ 66
L2 Features ................................................................................................................................... 68
Jumbo Frame .............................................................................................................................................................. 68
VLANs ......................................................................................................................................................................... 69
Understanding IEEE 802.1p Priority ........................................................................................................................................ 69
VLAN Description ..................................................................................................................................................................... 69
IEEE 802.1Q VLANs ................................................................................................................................................................ 70
Double VLANs ......................................................................................................................................................................... 73
802.1Q VLAN ........................................................................................................................................................................... 75
Voice VLAN................................................................................................................................................................. 79
Voice VLAN Global Settings .................................................................................................................................................... 79
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
iv
Voice VLAN Port Settings ........................................................................................................................................................ 80
Voice VLAN OUI Settings ........................................................................................................................................................ 81
Subnet-based VLAN ................................................................................................................................................... 82
Subnet-based VLAN Settings .................................................................................................................................................. 83
VLAN Precedence Settings...................................................................................................................................................... 84
Q-in-Q ......................................................................................................................................................................... 85
Q-in-Q Settings ........................................................................................................................................................................ 85
VLAN Translation Settings ....................................................................................................................................................... 86
Q-in-Q and VLAN Translation Rules ........................................................................................................................................ 87
802.1v Protocol VLAN ................................................................................................................................................ 87
802.1v Protocol Group Settings ............................................................................................................................................... 87
802.1v Protocol VLAN Settings ................................................................................................................................................ 88
RSPAN Settings ......................................................................................................................................................... 89
GVRP Settings ............................................................................................................................................................ 90
GVRP Timer Settings ................................................................................................................................................. 91
Asymmetric VLAN Settings ......................................................................................................................................... 91
MAC-based VLAN Settings ........................................................................................................................................ 92
PVID Auto Assign Settings ......................................................................................................................................... 92
VLAN Trunk Settings .................................................................................................................................................. 93
Port Trunking .............................................................................................................................................................. 94
LACP Port Settings ..................................................................................................................................................... 96
Traffic Segmentation ................................................................................................................................................... 97
IGMP Snooping .......................................................................................................................................................... 98
IGMP Snooping Settings .......................................................................................................................................................... 98
IGMP Snooping Rate Limit Settings ....................................................................................................................................... 100
IGMP Snooping Static Group Settings ................................................................................................................................... 101
IGMP Multicast Group Profile Settings ................................................................................................................................... 101
IGMP Snooping Multicast VLAN Settings .............................................................................................................................. 102
IPv4 Multicast Profile Settings ................................................................................................................................................ 103
IPv4 Limited Multicast Range Settings ................................................................................................................................... 104
IPv4 Max Multicast Group Settings ........................................................................................................................................ 104
Multicast Filtering Mode ......................................................................................................................................................... 105
CPU Filter L3 Control Packet Settings ................................................................................................................................... 106
MLD Snooping Settings ............................................................................................................................................ 107
MLD Snooping Settings ......................................................................................................................................................... 107
MLD Snooping Rate Limit Settings ........................................................................................................................................ 110
MLD Snooping Static Group Settings .................................................................................................................................... 111
MLD Multicast Group Profile Settings .................................................................................................................................... 111
MLD Snooping Multicast VLAN Settings ................................................................................................................................ 112
Port Mirror ................................................................................................................................................................. 113
Loopback Detection Settings .................................................................................................................................... 114
BPDU Attack Protection Settings ............................................................................................................................. 115
Spanning Tree .......................................................................................................................................................... 116
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
v
STP Bridge Global Settings ................................................................................................................................................... 118
STP Port Settings .................................................................................................................................................................. 120
MST Configuration Identification ............................................................................................................................................ 121
STP Instance Settings ........................................................................................................................................................... 122
MSTP Port Information .......................................................................................................................................................... 123
Forwarding & Filtering ............................................................................................................................................... 124
Unicast Forwarding ................................................................................................................................................................ 124
Multicast Forwarding .............................................................................................................................................................. 124
LLDP ......................................................................................................................................................................... 125
LLDP Global Settings ............................................................................................................................................................. 125
LLDP Port Settings ................................................................................................................................................................ 126
LLDP Management Address List ........................................................................................................................................... 127
LLDP Basic TLVs Settings ..................................................................................................................................................... 128
LLDP Dot1 TLVs Settings ...................................................................................................................................................... 129
LLDP Dot3 TLVs Settings ...................................................................................................................................................... 130
LLDP Statistics System .......................................................................................................................................................... 131
LLDP Local Port Information .................................................................................................................................................. 131
LLDP Remote Port Information .............................................................................................................................................. 132
CFM .......................................................................................................................................................................... 133
CFM Port Settings .................................................................................................................................................................. 133
CFM CCM PDUs Forwarding Mode ....................................................................................................................................... 133
CFM MPs Reply LTRs ........................................................................................................................................................... 134
CFM Mipccm List ................................................................................................................................................................... 134
Connectivity Fault Management Settings ............................................................................................................................... 135
CFM Loopback Settings ......................................................................................................................................................... 136
CFM Linktrace Settings .......................................................................................................................................................... 137
CFM Packet Counter List ....................................................................................................................................................... 138
CFM Packet Counter CCM List .............................................................................................................................................. 138
Browse CFM Fault Mep ......................................................................................................................................................... 139
Browse CFM Port MP List ...................................................................................................................................................... 139
Ethernet OAM ........................................................................................................................................................... 139
Ethernet OAM Settings .......................................................................................................................................................... 140
Ethernet OAM Configuration Settings .................................................................................................................................... 141
L3 Features ................................................................................................................................. 142
IPv4 Interface Settings .............................................................................................................................................. 142
IPv4 Default Route Settings...................................................................................................................................... 143
Gratuitous ARP ......................................................................................................................................................... 144
Gratuitous ARP Global Settings ............................................................................................................................................. 144
Gratuitous ARP Settings ........................................................................................................................................................ 145
ARP Spoofing Prevention Settings ........................................................................................................................... 145
DNS Relay ................................................................................................................................................................ 146
DNS Relay Global Settings .................................................................................................................................................... 146
DNS Relay Static Settings ..................................................................................................................................................... 147
DHCP Server ............................................................................................................................................................ 147
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
vi
DHCP Server Global Settings ................................................................................................................................................ 148
DHCP Server Excluded Address Settings ............................................................................................................................. 149
DHCP Server Pool Settings ................................................................................................................................................... 149
DHCP Server Manual Binding ................................................................................................................................................ 151
Policy Route Settings ................................................................................................................................................ 152
QoS ............................................................................................................................................. 154
Advantages of QoS ................................................................................................................................................................ 154
Understanding QoS ............................................................................................................................................................... 155
HOL Blocking Pevention ........................................................................................................................................... 156
Bandwidth Control .................................................................................................................................................... 157
Traffic Control ........................................................................................................................................................... 157
802.1p Default Priority .............................................................................................................................................. 160
802.1p User Priority .................................................................................................................................................. 161
QoS Scheduling Mechanism .................................................................................................................................... 162
QoS Scheduling ........................................................................................................................................................ 163
CoS Bandwidth Control Settings .............................................................................................................................. 164
SRED ........................................................................................................................................................................ 165
SRED Settings ....................................................................................................................................................................... 165
SRED Drop Counter .............................................................................................................................................................. 166
DSCP Trust Settings .............................................................................................................................................................. 167
DSCP Map Settings ............................................................................................................................................................... 168
802.1p Map Settings .............................................................................................................................................................. 170
Security ....................................................................................................................................... 171
Safeguard Engine ..................................................................................................................................................... 171
Trusted Host ............................................................................................................................................................. 173
IP-MAC-Port Binding ................................................................................................................................................ 173
IMP Binding Global Settings .................................................................................................................................................. 174
IMP Binding Port Settings ...................................................................................................................................................... 175
IMP Binding Entry Settings .................................................................................................................................................... 176
DHCP Snooping Entries ........................................................................................................................................................ 177
MAC Block List ....................................................................................................................................................................... 177
Port Security ............................................................................................................................................................. 177
Port Security Settings ............................................................................................................................................................ 177
Port Security FDB Entries ...................................................................................................................................................... 179
DHCP Server Screening Settings ............................................................................................................................. 179
DHCP Screening Port Settings .............................................................................................................................................. 180
DHCP Offer Filtering .............................................................................................................................................................. 181
802.1X ....................................................................................................................................................................... 181
802.1X Force Disconnect ....................................................................................................................................................... 186
802.1X Global Settings .......................................................................................................................................................... 186
802.1X Settings ...................................................................................................................................................................... 188
802.1X User ........................................................................................................................................................................... 189
Authentication RADIUS Server .............................................................................................................................................. 190
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
vii
RADIUS Attributes Assignment .............................................................................................................................................. 191
Guest VLAN Configuration ..................................................................................................................................................... 193
Guest VLAN ........................................................................................................................................................................... 194
SSL Settings ............................................................................................................................................................. 194
Download Certificate .............................................................................................................................................................. 195
Ciphersuite ............................................................................................................................................................................. 195
SSH ........................................................................................................................................................................... 197
SSH Settings .......................................................................................................................................................................... 197
SSH Authmode and Algorithm Settings ................................................................................................................................. 198
SSH User Authentication Lists ............................................................................................................................................... 199
Access Authentication Control .................................................................................................................................. 201
Authentication Policy Settings ................................................................................................................................................ 202
Application Authentication Settings ........................................................................................................................................ 202
Authentication Server Group .................................................................................................................................................. 203
Authentication Server ............................................................................................................................................................. 204
Login Method Lists ................................................................................................................................................................. 205
Enable Method Lists .............................................................................................................................................................. 206
Local Enable Password Settings ............................................................................................................................................ 207
RADIUS Accounting Services ................................................................................................................................................ 208
MAC-based Access Control...................................................................................................................................... 209
MAC-based Access Control Settings ..................................................................................................................................... 209
MAC-based Access Control Local Settings............................................................................................................................ 211
Web Authentication ................................................................................................................................................... 212
Web-based Access Control Settings ...................................................................................................................................... 214
Web-based Access Control User Settings ............................................................................................................................. 215
Web-based Access Control Port Settings .............................................................................................................................. 216
JWAC (Japanese Web-based Access Control) ........................................................................................................ 217
JWAC Global Settings ........................................................................................................................................................... 217
JWAC Port Settings ............................................................................................................................................................... 219
JWAC User Settings .............................................................................................................................................................. 220
JWAC Customize Page Language ......................................................................................................................................... 220
JWAC Customize Page ......................................................................................................................................................... 221
NetBIOS Filtering Settings ........................................................................................................................................ 221
Multiple Authentication .............................................................................................................................................. 222
Multiple Authentication Settings ............................................................................................................................................. 224
Guest VLAN ........................................................................................................................................................................... 225
ACL ............................................................................................................................................. 226
ACL Configuration Wizard ........................................................................................................................................ 226
Access Profile List .................................................................................................................................................... 228
CPU Interface Filtering ............................................................................................................................................. 244
CPU Access Profile List ............................................................................................................................................ 245
ACL Finder ................................................................................................................................................................ 256
ACL Flow Meter ........................................................................................................................................................ 256
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
viii
Monitoring .................................................................................................................................. 259
Device Status ............................................................................................................................................................ 259
Cable Diagnostics ..................................................................................................................................................... 260
CPU Utilization .......................................................................................................................................................... 261
Port Utilization ........................................................................................................................................................... 262
Packet Size ............................................................................................................................................................... 263
Packets ..................................................................................................................................................................... 265
Received (RX) ........................................................................................................................................................................ 265
UMB_cast (RX) ...................................................................................................................................................................... 267
Transmitted (TX) .................................................................................................................................................................... 268
Errors ........................................................................................................................................................................ 270
Received (RX) ........................................................................................................................................................................ 270
Transmitted (TX) .................................................................................................................................................................... 272
Port Access Control .................................................................................................................................................. 273
RADIUS Authentication .......................................................................................................................................................... 274
RADIUS Account Client ......................................................................................................................................................... 275
Authenticator State ................................................................................................................................................................ 277
Authenticator Statistics .......................................................................................................................................................... 277
Authenticator Session Statistics ............................................................................................................................................. 279
Authenticator Diagnostics ...................................................................................................................................................... 280
Browse ARP Table ................................................................................................................................................... 282
Browse Route Table ................................................................................................................................................. 282
Browse VLAN ........................................................................................................................................................... 282
Show VLAN Ports ..................................................................................................................................................... 283
Browse Voice VLAN Device ..................................................................................................................................... 283
Browse DHCP Server Dynamic Binding ................................................................................................................... 283
Browse DHCP Conflict IP ......................................................................................................................................... 284
Browse Session Table .............................................................................................................................................. 284
MLD Snooping .......................................................................................................................................................... 284
Browse MLD Router Port ....................................................................................................................................................... 284
MLD Snooping Group ............................................................................................................................................................ 285
MLD Snooping Forwarding .................................................................................................................................................... 285
Browse MLD Snooping Counter ............................................................................................................................................. 286
IGMP Snooping ........................................................................................................................................................ 286
Browse IGMP Router Port...................................................................................................................................................... 286
IGMP Snooping Group ........................................................................................................................................................... 287
IGMP Snooping Forwarding ................................................................................................................................................... 288
Browse IGMP Snooping Counter ........................................................................................................................................... 288
Ethernet OAM ........................................................................................................................................................... 288
Browse Ethernet OAM Event Log .......................................................................................................................................... 288
Browse Ethernet OAM Statistics ............................................................................................................................................ 289
JWAC Authentication State ...................................................................................................................................... 290
MBA Authentication State ......................................................................................................................................... 290
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
ix
WAC Authentication State ........................................................................................................................................ 290
ARP & FDB Table ..................................................................................................................................................... 291
MAC Address Table .................................................................................................................................................. 292
System Log ............................................................................................................................................................... 293
Save Services and Tools ........................................................................................................... 294
Save Configuration ID 1 ............................................................................................................................................ 294
Save Configuration ID 2 ............................................................................................................................................ 295
Save Log ................................................................................................................................................................... 295
Save All ..................................................................................................................................................................... 295
Configuration File Backup & Restore ....................................................................................................................... 296
Upload Log File ......................................................................................................................................................... 296
Reset ......................................................................................................................................................................... 296
Download Firmware .................................................................................................................................................. 297
Reboot System ......................................................................................................................................................... 297
Mitigating ARP Spoofing Attacks Using Packet Content ACL ............................................... 298
System Log and Trap List ......................................................................................................... 306
Glossary...................................................................................................................................... 318
Password Recovery Procedure ................................................................................................ 321
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
x
Intended Readers
The DES-3528/DES-3552 Series Manual contains information for setup and management of the Switch. This manual
is intended for network managers familiar with network management concepts and terminology.
Typographical Conventions
Convention Description
[ ]
In a command line, square brackets indicate an optional entry. For example: [copy
filename] means that optionally you can type copy followed by the name of the file. Do not
type the brackets.
Bold font
Indicates a button, a toolbar icon, menu, or menu item. For example: Open the File menu
and choose Cancel. Used for emphasis. May also indicate system messages or prompts
appearing on your screen. For example: You have mail. Bold font is also used to
represent filenames, program names and commands. For example: use the copy
command.
Boldface T
ypewriter
Font
Indicates commands and responses to prompts that must be typed exactly as printed in
the manual.
Initial capital letter
Indicates a window name. Names of keys on the keyboard have initial capitals. For
example: Click Enter.
Italics
Indicates a window name or a field. Also can indicate a variables or parameter that is
replaced with an appropriate word or string. For example: type filename means that you
should type the actual filename instead of the word shown in italic.
Menu N ame > Menu
Option
Menu Name > Menu Option Indicates the menu structure. Device > Port > Port
Properties means the Port Properties menu option under the Port menu option that is
located under the Device menu.
Notes, Notices, and Cautions
A NOTE indicates important information that helps you make better use of your device.
A NOTICE indicates either potential damage to hardware or loss of data and tells you
how to avoid the problem.
A CAUTION indicates a potential for property damage, personal injury, or death.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
11
Section 1
Web-based Switch Configuration
Introduction
Login to Web manager
Web-Based User Interface
Web Pages
Introduction
All software functions of the Switch can be managed, configured and monitored via the embedded web-based (HTML)
interface. The Switch can be managed from remote stations anywhere on the network through a standard browser
such as Firefox, Safari, or Microsoft Internet Explorer. The browser acts as a universal access tool and can
communicate directly with the Switch using the HTTP protocol.
The Web-based management module and the Console program (and Telnet) are different ways to access the same
internal switching software and configure it. Thus, all settings encountered in web-based management are the same
as those found in the console program.
Login to Web Manager
To begin managing the Switch, simply run the browser you have installed on your computer and point it to the IP
address you have defined for the device. The URL in the address bar should read something like:
http://123.123.123.123, where the numbers 123 represent the IP address of the Switch.
NOTE: The Factory default IP address for the Switch is 10.90.90.90.
This opens the management module's user authentication window, as seen below.
Figure 1 - 1 Enter Network Password dialog
Enter “admin” in both the User Name and Password fields and click OK. This will open the Web-based user interface.
The Switch management features available in the web-based manager are explained below.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
12
Web-based User Interface
The user interface provides access to various Switch configuration and management windows, allows you to view
performance statistics, and permits you to graphically monitor the system status.
Areas of the User Interface
The figure below shows the user interface. The user interface is divided into three distinct areas as described in the
table.
Figure 1 - 2 Main Web-Manager page
Area Function
Area 1
Select the folder or window to be displayed. The folder icons can be opened to display the
hyperlinked window buttons and subfolders contained within them. Click the D-Link logo to go to the
D-Link website.
Area 2
Presents a graphical near real-time image of the front panel of the Switch. This area displays the
Switch's ports and expansion modules, showing port activity, duplex mode, or flow control,
depending on the specified mode.
Various areas of the graphic can be selected for performing management functions, including port
configuration.
Area 2
Area 1
Area 3
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
13
Area 3
Presents switch information based on your selection and the entry of configuration data.
NOTICE: Any changes made to the Switch configuration during the current
session must be saved in the Save Changes web menu (explained below)
or use the command line interface (CLI) command save.
Web Pages
When you connect to the management mode of the Switch with a web browser, a login window is displayed. Enter a
user name and password to access the Switch's management mode.
Below is a list and description of the main folders available in the web interface:
Configuration – A detailed discussion about configuring some of the basic functions of the Switch, including
accessing the System Information, Serial Port Settings, IP Address, Port Configuration, Static ARP Settings, User
Accounts, System Log Configuration, System Severity Settings, DHCP Relay, DHCP Local Relay Settings, DHCP
Auto Configuration Settings, MAC Address Aging Time, Web Settings, Telnet Settings, Password Encryption,
Clipaging Settings, Firmware Information, Dual Configuration Settings, PPPoE Circuit ID Insertion Settings, Ping
Test, SNTP Settings, MAC Notification Settings, PoE, SNMP Settings, sFlow, Stacking Mode Settings, Time Range
Settings, and Single IP Management.
L2 Features – A discussion of the Layer 2 features on the Switch, including Jumbo Frame, 802.1Q VLAN, Voice
VLAN, Subenet VLAN, QinQ, 802.1v Protocol VLAN, RSPAN Settings, GVRP Settings, GVRP Timer Settings,
Asymmetric VLAN Settings, MAC-based VLAN Settings, PVID Auto Assign Settings, VLAN Trunk Settings, Port
Trunking, LACP Port Settings, Traffic Segmentation, IGMP Snooping, MLD Snooping, Port Mirror, Loopback
Detection Settings, BPDU Attack Protection Settings, Spanning Tree, Forwarding & Filtering, LLDP, CFM, and
Ethernet OAM.
L3 Features – A discussion of the Layer 3 features on the Switch, including Ipv4 Interface Settings, Ipv4 Default
Route Settings, Gratuitous ARP, ARP Spoofing Prevention Settings, DNS Relay, DHCP Server and Policy Route
Settings.
QoS – Features information on Switch QoS functions, including HOL Blocking Prevention, Bandwidth Control,
Traffic Control, 802.1p Default Priority, 802.1p User Priority, QoS Scheduling Mechanism, QoS Scheduling, CoS
Bandwidth Control Settings and SRED.
Security – Features information on Switch security functions, including Safeguard Engine, Trusted Host, IP-MAC-
Port Binding, Port Security, DHCP Server Screening, 802.1X, SSL Settings, SSH, Access Authentication Control,
MAC-based Access Control, Web Authentication, JWAC, NetBIOS Filtering Settings, and Multiple Authentication.
ACL – Discussion on the ACL functions of the Switch, including ACL Configuration Wizard, Access Profile List, CPU
Access Profile List, ACL Finder, and ACL Flow Meter.
Monitoring – Features information about the monitoring functions on the Switch including, Device Status, Cable
Diagnostics, CPU Utilization, Port Utilization, Packet Size, Packets, Errors, Port Access Control, Browse ARP Table,
Browse Route Table, Browse VLAN, Show VLAN Ports, Browse Voice VLAN Device, Browse DHCP Server
Dynamic Binding, Browse DHCP Conflict IP, Browse Session Table, MLD Snooping, IGMP Snooping, Ethernet
OAM, JWAC Authentication State, MBA Authentication State, WAC Authentication State, ARP & FDB Table, MAC
Address Table, and System Log.
NOTE: Be sure to configure the user name and password in the User
Accounts window before connecting the Switch to the greater network.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
14
Section 2
Configuration
Device Information
System Information
Serial Port Settings
IP Address
Port Configuration
Static ARP Settings
User Accounts
System Log Configuration
System Severity Settings
DHCP Relay
DHCP Local Relay Settings
DHCP Auto Configuration Settings
MAC Address Aging Time
Web Settings
Telnet Settings
Password Encryption
Clipaging Settings
Firmware Information
Dual Configuration Settings
PPPoE Circuit ID Insertion Settings
Ping Test
SNTP Settings
MAC Notification Settings
PoE
SNMP Settings
sFlow
Stacking Mode Settings
Time Range Settings
Single IP Management
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
15
Device Information
This window contains the main settings for all major functions on the Switch and appears automatically when you log
on. To return to the Device I nformation window, click the DES-3528 W eb M anagement T ool folder. The Device
Information window shows the Switch’s MAC Address (assigned by the factory and unchangeable), the Boot PROM
Version, Firmware V ersion, Hardware Ve rsion and Serial N umber as well as other information about different
settings on the Switch. This information is helpful to keep track of PROM and firmware updates and to obtain the
Switch's MAC address for entry into another network device's address table, if necessary. In addition, this window
displays the status of functions on the Switch to quickly assess their current global status. Some functions are hyper-
linked to their configuration window for easy access from the Device Information window.
Figure 2 - 1 Device Information window
System Information
This window contains the System Information details. The user may enter a System Name, System Location and
System C ontact to aid in defining the Switch, to the user's preference. This window displays the MAC Ad dress,
Firmware Version and Hardware Version.
Click Configuration > System Information to display the following window:
Figure 2 - 2 System Information window
The fields that can be configured are described below:
Parameter Description
System Name
Enter a system name for the Switch, if so desired. This name will identify it in the Switch
network.
System Location
Enter the location of the Switch, if so desired.
System Contact
Enter a contact name for the Switch, if so desired.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
16
Click Apply to implement changes made.
Serial Port Settings
The following window contains information about the Serial Port Settings to view this window click Configuration >
Serial Port Settings.
Figure 2 - 3 Serial Port Settings window
Parameter Description
Baud Rate
This field specifies the baud rate for the serial port on the Switch. There are four possible
baud rates to choose from, 9600, 19200, 38400 and 115200. For a connection to the Switch
using the CLI interface, the baud rate must be set to 115200, which is the default setting.
Auto Logout
Select the logout time used for the console interface. This automatically logs the user out after
an idle period of time, as defined. Choose from the following options: 2 Minutes, 5 Minutes, 10
Minutes, 15 Minutes or Never. The default setting is 10 minutes.
Click Apply to implement changes made.
IP Address
The IP address may initially be set using the console interface prior to connecting to it through the Ethernet. If the
Switch IP address has not yet been changed, read the introduction of the DES-3528/DES-3552 Series CLI Manual for
more information.
Click Configuration > IP Address to display the following window:
Figure 2 - 4 IP Address Settings window
To manually assign the Switch's IP address, subnet mask, and default gateway address:
1. Select Static at the top of the screen.
2. Enter the appropriate IP Address and Subnet Mask.
3. If you want to access the Switch from a different subnet from the one it is installed on, enter the IP address of
the Gateway. If you will manage the Switch from the subnet on which it is installed, you can leave the default
address (0.0.0.0) in this field.
4. If no VLANs have been previously configured on the Switch, you can use the default VLAN Name. The default
VLAN contains all of the Switch ports as members. If VLANs have been previously configured on the Switch,
NOTE: If a user configures the serial port’s baud rate, the baud rate will take effect and save
immediately. Baud rate settings will not change even if the user resets or reboots the Switch. The
Baud rate will only change when the user configures it again. The serial port’s baud rate setting is
not stored in the Switch’s configuration file. Resetting the Switch will not restore the baud rate to the
default setting.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
17
you will need to enter the Management VLAN Name of the VLAN that contains the port connected to the
management station that will access the Switch. The Switch will allow management access from stations with
the same VID listed here.
NOTE: The Switch's factory default IP address is 10.90.90.90 with a subnet
mask of 255.0.0.0 and a default gateway of 0.0.0.0.
To use the BOOTP or DHCP protocols to assign the Switch an IP address, subnet mask, and default gateway
address:
Select BOOTP or DHCP, this will determine how the Switch will be assigned an IP address.
The IP Address Settings options are:
Parameter Description
BOOTP
The Switch will send out a BOOTP broadcast request when it is powered up. The BOOTP
protocol allows IP addresses, network masks, and default gateways to be assigned by a central
BOOTP server. If this option is set, the Switch will first look for a BOOTP server to provide it with
this information before using the default or previously entered settings.
DHCP
The Switch will send out a DHCP broadcast request when it is powered up. The DHCP protocol
allows IP addresses, network masks, and default gateways to be assigned by a DHCP server. If
this option is set, the Switch will first look for a DHCP server to provide it with this information
before using the default or previously entered settings.
Static
Allows the entry of an IP address, Subnet Mask, and a Default Gateway for the Switch. These
fields should be of the form xxx.xxx.xxx.xxx, where each xxx is a number (represented in decimal
form) between 0 and 255. This address should be a unique address on the network assigned for
use by the network administrator.
Subnet Mask
A Bitmask that determines the extent of the subnet that the Switch is on. Should be of the form
xxx.xxx.xxx.xxx, where each xxx is a number (represented in decimal) between 0 and 255. The
value should be 255.0.0.0 for a Class A network, 255.255.0.0 for a Class B network, and
255.255.255.0 for a Class C network, but custom subnet masks are allowed.
Gateway
IP address that determines where packets with a destination address outside the current subnet
should be sent. This is usually the address of a router or a host acting as an IP gateway. If your
network is not part of an intranet, or you do not want the Switch to be accessible outside your
local network, you can leave this field unchanged.
Management
VLAN Name
This allows the entry of a VLAN Name from which a management station will be allowed to
manage the Switch using TCP/IP (in-band via web manager or Telnet). Management stations that
are on VLANs other than the one entered here will not be able to manage the Switch in-band
unless their IP addresses are entered in the Security IP Management window. If VLANs have
not yet been configured for the Switch, the default VLAN contains all of the Switch's ports. There
are no entries in the Security IP Management table, by default, so any management station that
can connect to the Switch can access the Switch until a management VLAN is specified or
Management Station IP Addresses are assigned.
Click Apply to allow changes to take effect.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
19
Port Configuration
This section contains information for configuring various attributes and properties for individual physical ports,
including port speed and flow control.
Port Settings
Click Configuration > Port Configuration > Port Settings to display the following window:
To configure switch ports:
Choose the port or sequential range of ports using the From Port and To Port pull-down menus.
Use the remaining pull-down menus to configure the parameters described below:
Figure 2 - 5 Port Settings window
The following parameters can be configured:
Parameter Description
From Port / To
Port
Use the pull-down menus to select the port or range of ports to be configured.
State
Toggle this field to either enable or disable a given port or group of ports.
Speed/Duplex
Toggle the Speed/Duplex field to either select the speed and duplex/half-duplex state of the
port. Auto denotes auto-negotiation between 10 and 100 Mbps devices, in full- or half-duplex.
The Auto setting allows the port to automatically determine the fastest settings the device the
port is connected to can handle, and then to use those settings. The other options are Auto,
10M/Half, 10M/Full, 100M/Half and 100M/Full, 1000M/Full_M, 1000M/Full_S and 1000M/Full.
There is no automatic adjustment of port settings with any option other than Auto.
The Switch allows the user to configure two types of gigabit connections; 1000M/Full_M and
1000M/Full_S. Gigabit connections only support full duplex connections and take on certain
characteristics that are different from the other choices listed.
The 1000M/Full_M (master) and 1000M/Full_S (slave) parameters refer to connections running
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
20
a 1000BASE-T cable for connection between the Switch port and other device capable of a
gigabit connection. The master setting (1000M/Full_M) will allow the port to advertise capabilities
related to duplex, speed and physical layer type. The master setting will also determine the
master and slave relationship between the two connected physical layers. This relationship is
necessary for establishing the timing control between the two physical layers. The timing control
is set on a master physical layer by a local source. The slave setting (1000M/Full_S) uses loop
timing, where the timing comes form a data stream received from the master. If one connection
is set for 1000M/Full_M, the other side of the connection must be set for 1000M/Full_S. Any
other configuration will result in a link down status for both ports.
Flow Control
Displays the flow control scheme used for the various port configurations. Ports configured for
full-duplex use 802.3x flow control, half-duplex ports use backpressure flow control, and Auto
ports use an automatic selection of the two. The default is Disabled.
Address
Learning
When Enabled, destination and source MAC addresses are automatically listed in the forwarding
table. The default setting is Enabled.
MDIX
This can be specified as Auto, Normal, or Cross. In Normal state, the port is in MDIX mode and
can be connected to PC NIC using a straight cable. If it is in Cross state, the port is in MDI
mode, and can be connected to a port (in MDIX mode) on another switch through a straight
cable.
Medium Type
This applies only to the Combo ports. If configuring the Combo ports this defines the type of
transport medium used. SFP ports should be set at Fiber and the Combo 1000BASE-T ports
should be set at Copper.
Click Apply to implement the new settings on the Switch.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
21
Port Description
The Switch supports a port description feature where the user may name various ports on the Switch. To assign
names to various ports, click Configuration > Port Configuration > Port Description to view the following window:
Use the From Port and To Port pull-down menus to choose a port or range of ports to describe, and then enter a
description of the port(s). Click Apply to set the descriptions in the Port Description Table.
The Medium Type applies only to the Combo ports. If configuring the Combo ports this defines the type of tranport
medium used. SFP ports should be nominated Fiber and the Combo 1000BASE-T ports should be nominated Copper.
The result will be displayed in the appropriate switch port number slot (C for copper ports and F for fiber ports).
Figure 2 - 6 Port Description window
The following parameters can be configured:
Parameter Description
From Port / T o
Port
Use the pull-down menus to select the port or range of ports to be configured.
Medium Type
This only applies to the Combo ports. If configuring the Combo ports, this defines the type of
transport medium used. SFP ports should be set at Fiber and the Combo 1000BASE-T ports
should be set at Copper.
Description
The Description of the the ports.
Click Apply to implement the new settings on the Switch.
Port Error Disabled
The following window will display the information about ports that have had their connection status disabled, for
reasons such as STP loopback detection or link down status. To view this window, click Configuration > Po rt
Configuration > Port Error Disabled:
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
22
Figure 2 - 7 Port Error Disabled window
The following parameters are displayed:
Parameter Description
Port
Displays the port that has been error disabled.
Port State
Describes the current running state of the port, whether Enabled or Disabled.
Connection Status
This field will read the uplink status of the individual ports, whether Enabled or Disabled.
Reason
Describes the reason why the port has been error-disabled, such as a STP loopback
occurrence.
Static ARP Settings
The Address Resolution Protocol (ARP) is a TCP/IP protocol that converts IP addresses into physical addresses. This
table allows network managers to view, define, modify and delete ARP information for specific devices. Static entries
can be defined in the ARP Table. When static entries are defined, a permanent entry is entered and is used to
translate IP address to MAC addresses.
To view this window, click Configuration > Static ARP Settings:
Figure 2 - 8 Static ARP Settings window
The following fields can be set:
Parameter
Description
ARP Aging Time
(0 or 30-3932100)
The user may globally set the maximum amount of time, in seconds, that an Address
Resolution Protocol (ARP) entry can remain in the Switch’s ARP table, without being
accessed, before it is dropped from the table. The value may be set in the range of 0 or 30-
3932100 seconds with a default setting of 1200 seconds.
IP Address
The IP address of the ARP entry.
MAC Address
The MAC address of the ARP entry.
After entering the IP Address and MAC Address of the Static ARP entry, click Apply to implement the new entry. To
completely clear the Static ARP Settings, click the Delete All button. To modify a static ARP entry, click the
corresponding Edit button in the table. To delete a static ARP entry, click the corresponding Delete button in the table.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
23
NOTE: The Switch supports up to 255 static ARP entries.
User Accounts
Use the User Account M anagement window to control user privileges, create new users and view existing User
Accounts. To view this window, click Configuration > User Accounts:
Figure 2 - 9 User Accounts window
The following fields can be set:
Parameter
Description
User Name
The name of the user, an alphanumeric string of up to 15 characters.
Access Right
There are three levels of user privileges, Admin, O perator and User. Some menu selections
available to users with Admin privileges may not be available to those with User or Operator
level privileges.
There are 3 levels of security offered on the Switch, the Operator level privilege will allow users
to configure and view configurations on the Switch, except for those involving security features,
which are still left to the Admin level privilege. Operator level users can be authenticated through
either the local authentication method of the Switch, or through the Access Authentication Control
feature, discussed later in this document. Once the user has logged in to the Switch in the
Operator level, certain security screens and windows will not be made available to view, or to
configure. Only Admin level users have access to these features.
(Table 2 - 1 below summarizes Admin, Operator and User level privileges)
Password
Enter a password for the new user.
Confirm
Password
Retype the new password.
To add a new user, enter the appropriate information and click Apply. To modify or delete an existing user, click on
the Edit button for that user.
NOTICE: In case of lost passwords or password corruption, please refer to the
D-Link website and the White Paper entitled “Password Recovery Procedure”,
which will guide you through the steps necessary to resolve this issue.
Admin, Operator and User Privileges
Recently added to the levels of security offered on the Switch, the Operator level privilege will allow users to configure
and view configurations on the Switch, except for those involving security features, which are still left to the Admin
privilege. Operator users can be authenticated through either the local authentication method of the Switch, or through
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
24
the Access Authentication Control feature, discussed later in this document. Once the user has logged in to the Switch
in the Operator level, certain security screens and windows will not be made available to view, or to configure. Only
Admin level users have access to these features.
There are three levels of user privileges, Admin, Operator and User. Some menu selections available to users with
Admin privileges may not be available to those with User or Operator privileges.
The following table summarizes the Admin, Operator and User privileges:
Management Admin Operator User
Configuration
Yes
Yes
Read-only
Network Monitoring
Yes
Yes
Read-only
Community Strings and Trap Stations
Yes
Yes
Read-only
Update Firmware and Configuration Files
Yes
No
No
System Utilities
Yes
Yes
No
Factory Reset
Yes
No
No
User Account Management
Add/Update/Delete User Accounts
Yes
No
No
View User Accounts
Yes
No
No
Table 2 - 1 Admin, Operator and User Privileges
System Log Configuration
This section contains information for configuring various attributes and properties for System Log Configurations,
including System Log Settings and System Log Host.
System Log Settings
This window allows the user to enable or disable the System Log and specify the System Log Save Mode Settings. To
configure the system log settings click Configuration > System Log Configuration > System Log Settings
Figure 2 - 10 System Log Settings window
The following parameters can be set:
Parameter Description
Save Mode
Use this drop-down menu to choose the method that will trigger a log entry. You can choose
between On Demand, Time Interval, and Log Trigger.
Minutes (1-65535)
Enter a time interval, in seconds, for which you would like a log entry to be made.
To add a new entry, enter the appropriate information and click Apply. To save the current Log Settings, click Save
Log.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
25
System Log Server
The Switch can send Syslog messages to up to four designated servers using the System Log Server.
To configure the system log settings click Configuration > System Log Configuration > System Log Server
Figure 2 - 11 System Log Server window
The following parameters can be set:
Parameter Description
Server ID
Syslog server settings index (1-4).
Server IP Address
The IP address of the Syslog server.
UDP Port
(514 or 6000-65535)
Type the UDP port number used for sending Syslog messages. The default is 514.
Severity
This drop-down menu allows you to select the level of messages that will be sent. The options
are Warning, Informational, and All.
Facility
Some of the operating system daemons and processes have been assigned Facility values.
Processes and daemons that have not been explicitly assigned a Facility may use any of the
"local use" facilities or they may use the "user-level" Facility. Those Facilities that have been
designated are shown in the following: Bold font indicates the facility values that the Switch is
currently employing.
Numerical Facility Code Numerical Facility Code
0
1
2
3
4
5
7
8
9
10
11
kernel messages
user-level messages
mail system
system daemons
security/authorization messages
messages generated internally by
syslog line printer subsystem
network news subsystem
UUCP subsystem
clock daemon
security/authorization messages
FTP daemon
12
13
14
15
16
17
18
19
20
21
22
23
NTP subsystem
log audit
log alert
clock daemon
local use 0 (local0)
local use 1 (local1)
local use 2 (local2)
local use 3 (local3)
local use 4 (local4)
local use 5 (local5)
local use 6 (local6)
local use 7 (local7)
Status
Choose Enabled or Disabled to activate or deactivate.
To add a new entry, enter the appropriate information and click Apply.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
26
System Severity Settings
The Switch can be configured to allow alerts be logged or sent as a trap to an SNMP agent or both. The level at which
the alert triggers either a log entry or a trap message can be set as well. Use the System Severity Settings menu to
set the criteria for alerts. The current settings are displayed below the Settings menu. To view this window click
Configuration > System Severity Settings
Figure 2 - 12 System Severity Settings
Use the drop-down menus to configure the parameters described below.
Parameter Description
System Severity
Choose how the alerts are used from the drop-down menu. Select Log to send the alert of the
Severity Type configured to the Switch’s log for analysis. Choose Trap to send it to an SNMP
agent for analysis. Select All to send the chosen alert type to an SNMP agent and the
Switch’s log for analysis.
Severity Level
Choose what level of alert will trigger sending the log entry or trap message as defined by the
Severity Name. Select Critical to send only critical events to the Switch’s log or SNMP agent.
Choose Warning to send critical and warning events to the Switch’s log or SNMP agent.
Select Information to send informational, warning and critical events to the Switch’s log or
SNMP agent.
Click Apply to implement the new System Severity Settings.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
27
DHCP Relay
The relay hops count limit allows the maximum number of hops (routers) that the DHCP messages can be relayed
through to be set. If a packet’s hop count is equal to or more than the hop count limit, the packet is dropped. The
range is between 1 and 16 hops, with a default value of 4. The relay time threshold sets the minimum time (in
seconds) that the Switch will wait before forwarding a BOOTREQUEST packet. If the value in the seconds field of the
packet is less than the relay time threshold, the packet will be dropped. The range is between 0 and 65,535 seconds,
with a default value of 0 seconds.
DHCP Relay Global Settings
To enable and configure DHCP Relay Global Settings on the Switch, click Configuration > DHCP Relay > DHCP
Relay Global Settings
Figure 2 - 13 DHCP Relay Global Settings window
The following fields can be set:
Parameter
Description
DHCP Relay State
This field can be toggled between Enabled and Disabled using the pull-down menu. It is
used to enable or disable the DHCP Relay service on the Switch. The default is Disabled
DHCP Relay Hops
Count Limit (1-16)
This field allows an entry between 1 and 16 to define the maximum number of router hops
DHCP messages can be forwarded across. The default hop count is 4.
DHCP Relay Time
Threshold (0-65535)
Allows an entry between 0 and 65535 seconds, and defines the maximum time limit for
routing a DHCP packet. If a value of 0 is entered, the Switch will not process the value in
the seconds field of the BOOTP or DHCP packet. If a non-zero value is entered, the Switch
will use that value, along with the hop count to determine whether to forward a given
BOOTP or DHCP packet.
DHCP Relay Option
82 State
This field can be toggled between Enabled and Disabled using the pull-down menu. It is
used to enable or disable the DHCP Agent Information Option 82 on the Switch. The default
is Disabled.
Enabled – When this field is toggled to Enabled the relay agent will insert and remove
DHCP relay information (option 82 field) in messages between DHCP servers and clients.
When the relay agent receives the DHCP request, it adds the option 82 information, and the
IP address of the relay agent (if the relay agent is configured), to the packet. Once the
option 82 information has been added to the packet it is sent on to the DHCP server. When
the DHCP server receives the packet, if the server is capable of option 82, it can implement
policies like restricting the number of IP addresses that can be assigned to a single remote
ID or circuit ID. Then the DHCP server echoes the option 82 field in the DHCP reply. The
DHCP server unicasts the reply to the back to the relay agent if the request was relayed to
the server by the relay agent. The switch verifies that it originally inserted the option 82
data. Finally, the relay agent removes the option 82 field and forwards the packet to the
switch port that connects to the DHCP client that sent the DHCP request.
Disabled - If the field is toggled to Disabled the relay agent will not insert and remove DHCP
relay information (option 82 field) in messages between DHCP servers and clients, and the
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
28
check and policy settings will have no effect.
DHCP Relay Agent
Information Option 82
Check
This field can be toggled between Enabled and Disabled using the pull-down menu. It is
used to enable or disable the Switches ability to check the validity of the packet’s option 82
field.
Enabled – When the field is toggled to Enable, the relay agent will check the validity of the
packet’s option 82 field. If the switch receives a packet that contains the option-82 field from
a DHCP client, the switch drops the packet because it is invalid. In packets received from
DHCP servers, the relay agent will drop invalid messages.
Disabled - When the field is toggled to Disabled, the relay agent will not check the validity of
the packet’s option 82 field.
DHCP Relay Agent
Information Option 82
Policy
This field can be toggled between Replace, Drop, and Keep by using the pull-down menu.
It is used to set the Switches policy for handling packets when the DHCP A gent
Information Option 82 Check is set to Disabled. The default is Replace.
Replace - The option 82 field will be replaced if the option 82 field already exists in the
packet received from the DHCP client.
Drop - The packet will be dropped if the option 82 field already exists in the packet received
from the DHCP client.
Keep -The option 82 field will be retained if the option 82 field already exists in the packet
received from the DHCP client.
DHCP Relay Agent
Information Option 82
Remote ID
This field is for you to enter the remote ID. Tick Default to use the Switch’s system MAC
address as the remote ID.
DHCP Relay Option
60 State
This function enables or disables the DHCP option 60 state. When option 60 is enabled, if
the packet does not have option 60, then the relay servers cannot be determined based on
option 60. As a result, the relay servers will be determined based on either option 61 or per
IPIF configured servers. If the relay servers are determined based on option 60, then the
IPIF configured servers will be ignored. If the relay servers are not determined by option 60
then the IPIF configured servers will be used to determine the relay servers.
DHCP Relay Option
61 State
This function enables or disables the DHCP option 61 state. When option 61 is enabled, if
the packet does not have option 61, then the relay servers cannot be determined based on
option 61. If the relay servers are determined based on option 61, then the IPIF configured
servers will be ignored. If the relay servers are not determined either by option 60 or option
61, then IPIF configured servers will be used to determine the relay servers.
Click Apply to implement any changes that have been made.
NOTE: If the Switch receives a packet that contains the option-82 field from a DHCP client and the
information-checking feature is enabled, the switch drops the packet because it is invalid. However, in
some instances, you might configure a client with the option-82 field. In this situation, you should
disable the information-check feature so that the switch does not remove the option-82 field from the
packet. You can configure the action that the switch takes when it receives a packet with existing
option-82 information by configuring the DHCP Agent Information Option 82 Policy.
The Implementation of DHCP Information Option 82 on the Switch
The config dhcp_relay o ption_82 command configures the DHCP relay agent information option 82 setting of the
switch. The formats for the circuit ID sub-option and the remote ID sub-option are as follows:
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
29
NOTE: For the circuit ID sub-option of a standalone switch, the module field is always zero.
Circuit ID sub-option format:
1. 2. 3. 4. 5. 6. 7.
1
6
0
4
VLAN
Module
Port
1 byte 1 byte 1 byte 1 byte 2 bytes 1 byte 1 byte
a. Sub-option type
b. Length
c. Circuit ID type
d. Length
e. VLAN: the incoming VLAN ID of DHCP client packet.
f.
Module: For a standalone switch, the Module is always 0; For a stackable switch, the Module is the
Unit ID.
g. Port: The incoming port number of DHCP client packet, port number starts from 1.
Remote ID sub-option format: (default)
1. 2. 3. 4. 5.
2
8
0
6
MAC address
1 byte 1 byte 1 byte 1 byte 6 bytes
1. Sub-option type
2. Length
3. Remote ID type
4. Length
5. MAC address: The Switch’s system MAC address.
Remote ID sub-option format:(for user-configured string)
1. 2. 3. 4. 5.
2
N+2
1
N
ASCII Remote ID String (up to 127 characters)
1 byte 1 byte 1 byte 1 byte N bytes
1. Sub-option type
2. Length
3. Remote ID type
4. Length
5. User configured Remote-ID
Figure 2 - 14 Circuit ID and Remote ID Sub-option Format
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
30
DHCP Relay Interface Settings
This window allows the user to set up a server, by IP address, for relaying DHCP/ BOOTP information to the DHCP
server. The user may enter a previously configured IP interface on the Switch that will be connected directly to the
DHCP server using the following window. Properly configured settings will be displayed in the DHCP Relay Interface
Table at the bottom of the following window. The user may add up to four server IP’s per IP interface on the Switch.
To enable and configure DHCP Relay Global Settings on the Switch, click Configuration > DHCP Relay > DHCP
Relay Interface Settings
Figure 2 - 15 DHCP Relay Interface Settings and DHCP Relay Interface Table window
The following parameters may be configured or viewed.
Parameter Description
Interface
The IP interface on the Switch that will be connected directly to the Server.
Server IP
Enter the IP address of the DHCP server. Up to four server IPs can be configured per IP
Interface
DHCP Relay Option 60 Default Settings
This window allows the user to configure the DHCP Relay Option 60 Default servers. When there is no matching
server found for the packet based on option 60, the relay servers will be determined by the default relay server setting.
To view this window, click Configuration > D HCP Relay > DHCP R elay O ption 6 0 D efault Settings as shown
below:
Figure 2 - 16 DHCP Relay Option 60 Default Settings window
The following parameters may be configured.
Parameter Description
Relay IP Address
Enter the specified IP address of the default relay server.
Mode
Use the pull down menu to choose either Relay or Drop. When drop is specified, the packet
with no matching rules found will be dropped without further process. When relay is selected
the packet will be relayed based on the relay rules.
Click Add to add a new Relay IP Address entry. Click Apply to implement changes made. To remove any entries click
the corresponding Delete button.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
31
DHCP Relay Option 60 Settings
This window is used to configure option 60 relay rules on the Switch. Different strings can be specified for the same
relay server, and the same string can be specified with multiple relay servers. The system will relay the packet to all
the matching servers.
To view this window, click Configuration > DHCP Relay > DHCP Relay Option 60 Settings as shown below:
Figure 2 - 17 DHCP Relay Option 60 Settings window
The following parameters may be configured.
Parameter Description
String
Enter the specified string, up to a maximum of 255 alphanumeric characters.
Server IP
Enter the relay server IP address.
Match Type
Use the drop down menu to select either Exact Match or Partial Match.
Exact Match – The option 60 string in the packet must fully match the specified string.
Partial Match – The option 60 string in the packet only needs to partially match the specified
string.
Click Add to add a new entry. To search for a particular entry enter the correct IP Address or String and click Find. To
delete an entry select it and click Delete.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
32
DHCP Relay Option 61 Default Settings
This window is used to configure the DHCP Relay Option 61 Default Settings. These settings are used to determine
the rule to process those packets that have no option 61 matching rules.
To view this window, click Configuration > DHCP Relay > DHCP Relay Option 61 Default Settings as shown
below:
Figure 2 - 18 DHCP Relay Option 61 Default Settings window
The following parameters may be configured.
Parameter Description
DHCP R elay O ption
61 Default
Use the pull down menu to choose either Relay or Drop. When drop is specified, the packet
with no matching rules found will be dropped without further process. When relay is selected
the packet will be relayed based on the relay rules.
Enter the IP Address of the default relay server. When there is no matching server found for
the packet based on option 61, the relay servers will be determined by this default relay
server setting.
Click Apply to implement changes made.
DHCP Relay Option 61 Settings
This command is used to add a rule to the relay server based on option 61. The matching rule can be based on either
the MAC address or the user-specified string. Only one relay server can be specified for a MAC-address or a string.
Both option 60 and option 61 can be assigned to a specific DHCP server based on whether they match the
configuration in the DHCP packet. If several relay servers are determined by option 60, and one relay server is
determined by option 61, the final relay servers will be determined by both option 60 and 61.
To view this window, click Configuration > DHCP Relay > DHCP Relay Option 61 Settings as shown below:
Figure 2 - 19 DHCP Relay Option 61 Settings window
The following parameters may be configured.
Parameter Description
Client ID
Use the drop down menu to select the method of identification for the Client ID either MAC
Address or String. The MAC Address will specify the hardware address of the client and the
String will specify the client ID. Choose a method and enter the appropriate information into
the box provided.
Relay Rule
Use the pull down menu to choose either Relay or Drop. When drop is specified, the packet
with no matching rules found will be dropped without further process. When relay is selected
the packet will be relayed based on the relay rules. Choose a method and enter the
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
33
appropriate information into the box provided.
Click Add to create a new entry. To remove an entry, enter the appropriate Client ID information and click Delete. To
delete all entries click Delete All.
DHCP Local Relay Settings
This function on the Switch allows to configure the DHCP Local relay for VLAN.
To view this window, click Configuration > DHCP Local Relay Settings as shown below:
Figure 2 - 20 DHCP Local Relay Settings window
The following parameters may be configured.
Parameter Description
DHCP/BOOTP L ocal
Relay Status
It is used to enable or disable the DHCP Local Relay service on the Switch. The default is
Disabled.
VLAN Name
Enter a name of the VLAN to be enabled by DHCP local relay.
State
This is used to enable or disable the DHCP local relay for the specified VLAN.
DHCP Auto Configuration Settings
The DHCP autoconfiguration function on the Switch will load a previously saved configuration file for current use.
When DHCP autoconfiguration is Enabled on the Switch, the DHCP reply will contain a configuration file and path
name. It will then request the file from the TFTP server specified in the reply.
To view this window, click Configuration > DHCP Auto Configuration Settings as shown below:
Figure 2 - 21 DHCP Auto Configuration Settings window
When DHCP autoconfiguration is Enabled, the Switch becomes a DHCP client automatically after rebooting. The
DHCP server must have the TFTP server IP address and configuration file name, and be configured to deliver this
information in the data field of the DHCP reply packet. The TFTP server must be running and have the requested
configuration file in its base directory when the request is received from the Switch. Consult the DHCP server and
TFTP server software instructions for information on loading a configuration file.
If the Switch is unable to complete the autoconfiguration process the previously saved local configuration file present
in Switch memory will be loaded.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
34
MAC Address Aging Time
This table specifies the length of time a learned MAC Address will remain in the forwarding table without being
accessed (that is, how long a learned MAC Address is allowed to remain idle). To change this, enter a value
representing the MAC address age-out time in seconds. The MAC Address Aging Time can be set to any value
between 10 and 1,000,000 seconds. The default setting is 300 seconds.
To access this table, click Configuration > MAC Address Aging Time
Figure 2 - 22 MAC Address Aging Time window
Web Settings
Web-based management is Enabled by default. If you choose to disable this by selecting Disabled, you will lose the
ability to configure the system through the web interface as soon as these settings are applied. The TCP ports are
numbered between 1 and 65535. The "well-known" TCP port for the web protocol is 80.
To access this table, click Configuration > Web Settings
Figure 2 - 23 Web Settings window
Telnet Settings
Telnet configuration is Enabled by default. If you do not want to allow configuration of the system through Telnet
choose Disabled. The TCP ports are numbered between 1 and 65535. The "well-known" TCP port for the Telnet
protocol is 23.
To access this table, click Configuration > Telnet Settings
Figure 2 - 24 Telnet Settings window
Password Encryption
Password Encryption Status can be Enabled or Disabled in this window, it is Disabled by default. Password encryption
allows the user to encrypt a password for additional security. Select Enabled to change the password into encrypted
form. When password encryption is disabled, the password will be in plain text form. However, if the user specifies the
password in encrypted form, or if the password has been converted to encrypted form by the last Enable password
encryption command, the password will still be in encrypted form and cannot be reverted back to plaintext form.
To access this table, click Configuration > Password Encryption
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
35
Figure 2 - 25 Password Encryption window
Clipaging Settings
Clipaging Status can be Enabled or Disabled in this window, it is Enabled by default. Clipaging settings are used when
issuing a command which causes the console screen to rapidly scroll through several pages. This command will cause
the console to pause at the end of each page.
To access this table, click Configuration > Clipaging Settings
Figure 2 - 26 Clipaging Settings window
Firmware Information
The following screen allows the user to view information about current firmware images stored on the Switch.
To access this table, click Configuration > Firmware Information
Figure 2 - 27 Firmware Information window
This window holds the following information:
Parameter
Description
ID
States the image ID number of the firmware in the Switch’s memory. The Switch can store two
firmware images for use. Image ID 1 will be the default boot up firmware for the Switch unless
otherwise configured by the user.
Version
States the firmware version.
Size (Bytes)
States the size of the corresponding firmware, in bytes.
Update Time
States the specific time the firmware version was downloaded to the Switch.
From
States the IP address of the origin of the firmware. There are five ways firmware may be
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
36
downloaded to the Switch.
R – If the IP address has this letter attached, it denotes a firmware upgrade through the serial
port RS232.
T - If the IP address has this letter attached to it, it denotes a firmware upgrade through Telnet.
S - If the IP address has this letter attached to it, it denotes a firmware upgrade through the
Simple Network Management Protocol (SNMP).
W - If the IP address has this letter attached to it, it denotes a firmware upgrade through the
web-based management interface.
SSH – If the IP address has these three letters attached, it denotes a firmware update through
SSH.
SIM – If the IP address has these letters attached, it denotes a firmware upgrade through the
Single IP Management feature.
User
States the user who downloaded the firmware. This field may read “Anonymous” or “Unknown”
for users that are unidentified.
Dual Configuration Settings
The following window is used to manage configuration information in the Switch. The DES-3528/DES-3552 Series has
the capability to store two firmware images in its memory.
To access this table, click Configuration > Dual Configuration Settings
Figure 2 - 28 Dual Configuration Settings
This window holds the following information:
Parameter
Description
ID
States the ID number of the configuration file located in the Switch’s memory. The Switch can
store two configuration files for use. ID 1 will be the default boot up configuration file for the
Switch unless otherwise configured by the user.
Version
Displays the firmware version that has been saved or uploaded in the Switch.
Size (Bytes)
Displays the size of the configuration file, in bytes.
Update time
Displays the time that the configuration file was updated to the Switch.
From
Displays the location from which the configuration file was uploaded.
User
Displays the name of the user (device) that updated this configuration file. Unknown users will be
displayed as Anonymous.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
37
Boot
Click the Set Boot button under this heading to use this configuration file as the boot up
firmware for the Switch. This will apply upon the next reboot of the Switch.
Active
Click the Active button to enable the configuration file settings.
Delete
Click the Delete button under this heading to delete this configuration file from the Switch’s
memory.
PPPoE Circuit ID Insertion Settings
PPPoE Circuit ID Insertion can be Enabled or Disabled in this window, it is disabled by default. When the setting is
Enabled, the system will insert the circuit ID tag to the received PPPoE discover request and the request packet if the
tag is absent. It will remove the circuit ID tag from the received PPPoE offer and session confirmation packet.
To view this window, click Configuration > PPPoE Circuit ID Insertion Settings as shown below:
Figure 2 - 29 PPPoE Circuit ID Insertion Settings window
Ping Test
Ping is a small program that sends ICMP Echo packets to the IP address you specify. The destination node then
responds to or "echoes" the packets sent from the Switch. This is very useful to verify connectivity between the Switch
and other nodes on the network.
To access this table, click Configuration > Ping Test
Figure 2 - 30 Ping Test window
The user may use Infinite times radio button, in the Repeat Pinging for field, which will tell the ping program to keep
sending ICMP Echo packets to the specified IP address until the program is stopped. The user may opt to choose a
specific number of times to ping the Target I P Address by entering a number between 1 and 255. Click Start to
initiate the Ping program
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
38
SNTP Settings
The Simple Network Time Protocol (SNTP) is a protocol for synchronizing computer clocks through the Internet. It
provides comprehensive mechanisms to access national time and frequency dissemination services, organize the
SNTP subnet of servers and clients, and adjust the system clock in each participant.
Time Settings
To configure the time settings for the Switch, click Configuration > SNTP Settings > Time Settings
Figure 2 - 31 Time Settings window
The following parameters can be set or are displayed:
Parameter Description
Status
SNTP State
Use the radius button to select an Enabled or Disabled SNTP state.
Current Time
Displays the Current Time set on the Switch.
Time Source
Displays the time source for the system.
SNTP Settings
SNTP First Server
This is the IP address of the primary server the SNTP information will be taken from.
SNTP Second Server
This is the IP address of the secondary server the SNTP information will be taken from.
SNTP Po ll I nterval i n
Seconds (30-99999)
This is the interval, in seconds, between requests for updated SNTP information.
Set Current Time
Date (DD/MM/YYYY)
Enter the current date in day, month and year to update the system clock.
Time in (HH:MM:SS)
Enter the current time in hours, minutes, and seconds.
Click Apply to implement changes made.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
39
TimeZone Settings
The following window is used to configure time zones and Daylight Savings time settings for SNTP. To configure the
time Zone Settings for the Switch, click Configuration > SNTP Settings > TimeZone Settings
Figure 2 - 32 Time Zone and DST Settings window
The following parameters can be set:
Parameter Description
Time Zone and DST
Daylight Saving
Time State
Use this pull-down menu to enable or disable the DST Settings.
Daylight Saving
Time Offset in
Minutes
Use this pull-down menu to specify the amount of time that will constitute your local DST offset
30, 60, 90, or 120 minutes.
Time Zone Offset
from GMT in +/-
HH:MM
Use these pull-down menus to specify your local time zone's offset from Greenwich Mean
Time (GMT.)
DST Repeating Settings
Using repeating mode will enable DST seasonal time adjustment. Repeating mode requires that the DST beginning
and ending date be specified using a formula. For example, specify to begin DST on Saturday during the second
week of April and end DST on Sunday during the last week of October.
From: Which Week
of the Month
Enter the week of the month that DST will start on.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
40
From: Day of the
Week
Enter the day of the week that DST will start on.
From: Month
Enter the month DST will start on.
From: Time in
HH:MM
Enter the time of day that DST will start on.
To: Which Week of
the Month
Enter the week of the month the DST will end.
To: Day of the
Week
Enter the day of the week that DST will end.
To: Month
Enter the month that DST will end.
To:Time in HH:MM
Enter the time DST will end.
DST Annual Settings
Using annual mode will enable DST seasonal time adjustment. Annual mode requires that the DST beginning and
ending date be specified concisely. For example, specify to begin DST on April 3 and end DST on October 14.
From: Month
Enter the month DST will start on, each year.
From: Day
Enter the day of the week DST will start on, each year.
From: Time in
HH:MM
Enter the time of day DST will start on, each year.
To: Month
Enter the month DST will end, each year.
To: Day
Enter the date DST will end, each year.
To: Time in HH:MM
Enter the time of day that DST will end, each year.
Click Apply to implement changes made to the Time Zone and DST window.
MAC Notification Settings
MAC Notification is used to monitor MAC addresses learned and entered into the forwarding database. To globally set
MAC notification on the Switch, open the following window by opening the MAC Notification Settings in the
Configuration folder.
MAC Notification Global Settings
To configure the MAC Notification Global Settings for the Switch, click Configuration > MAC Notification Settings >
MAC Notification Global Settings
Figure 2 - 33 MAC Notification Global Settings window
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
41
The following parameters may be viewed and modified:
Parameter
Description
State
Enable or disable MAC notification globally on the Switch.
Interval
(1-2147483647 sec)
The time in seconds between notifications.
History Size
(1-500)
The maximum number of entries listed in the history log used for notification. Up to 500
entries can be specified.
Click Apply to implement changes.
MAC Notification Port Settings
To configure the MAC Notification Port Settings for the Switch, click Configuration > MAC Notification Settings >
MAC Notification Port Settings
Figure 2 - 34 MAC Notification Port Settings window
The following parameters may be modified:
Parameter
Description
From Port / To
Port
Select a port or group of ports to enable for MAC notification using the pull-down menus.
State
Enable MAC Notification for the ports selected using the pull-down menu.
Click Apply to implement changes.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
42
PoE
The DES-3528P switch supports Power over Ethernet (PoE) as defined by the IEEE 802.3af. Ports 1-8 can support
PoE up to 35W. Ports 1-24 can supply about 48 VDC power to Powered Devices (PDs) over Category 5 or Category 3
UTP Ethernet cables. The DES-3528P follows the standard PSE (Power Sourcing Equipment) pinout Alternative A,
whereby power is sent out over pins 1, 2, 3 and 6. The DES-3528P works with all D-Link 802.3af capable devices.
The DES-3528P includes the following PoE features:
•
Auto-discovery recognizes the connection of a PD (Powered Device) and automatically sends power to
it.
•
The Auto-disable feature occurs under two conditions: firstly, if the total power consumption exceeds
the system power limit; and secondly, if the per port power consumption exceeds the per port power
limit.
•
Active circuit protection automatically disables the port if there is a short. Other ports will remain active.
Based on 802.3af/at PDs receive power according to the following classification:
Class
Maximum power available to PD
0
12.95W
1
3.84W
2
6.49W
3
12.95W
4
29.5W
To configure the PoE features on the DES-3528P, click Configuration > PoE. The PoE System Settings window is
used to assign a power limit and power disconnect method for the whole PoE system. To configure the Power Limit
for the PoE system, enter a value between 37W and 370W for the DES-3528P in the Power Limit field. The default
setting is 370W. When the total consumed power exceeds the power limit, the PoE controller (located in the PSE)
disconnects the power to prevent overloading the power supply.
PSE provides power according to the following classification:
Class
Max power used by PSE
0
15.4W
1
4.0W
2
7.0W
3
15.4W
User define 35W (only for ports 1-8)
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
43
PoE System Settings
To configure PoE for the Switch, click Configuration > PoE > PoE System Settings, which will reveal the following
window for the user to configure:
Figure 2 - 35 PoE System Settings window
The following parameters can be configured:
Parameter Description
Power Limit
(37-370)
Sets the limit of power to be used from the Switch’s power source to PoE ports. The user may
configure a Power Limit between 37 and 370W for the DES-3528P. The default setting is
370W.
Power Disconnect
Method
The PoE controller uses either Deny Next Port or Deny Low Priority Port to offset the power
limit being exceeded and keeps the Switch’s power at a usable level. Use the drop down
menu to select a Power Disconnect Method. The default Power Disconnect Method is Deny
Next Port. Both Power Disconnection Methods are described below:
Deny Next Port - After the power limit has been exceeded, the next port attempting to power
up is denied, regardless of its priority. If Power Disconnection Method is set to Deny Next Port,
the system cannot utilize out of its maximum power capacity. The maximum unused watt is
19W.
Deny Low Priority Port - After the power limit has been exceeded, the next port attempting to
power up causes the port with the lowest priority to shut down so as to allow the high-priority
and critical priority ports to power up.
Click Apply to implement changes made.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
44
PoE Port Settings
To configure the PoE port settings on the Switch, click Configuration > PoE > PoE Port Settings, which will reveal
the following window for the user to configure:
Figure 2 - 36 PoE Port Settings window
The following parameters can be configured:
Parameter Description
From Port / To Port
Select a range of ports from the pull-down menus to be enabled or disabled for PoE.
State
Use the pull-down menu to enable or disable ports for PoE.
Time Range
Select a range of the time to the port set as POE. If Time Range is configured, the power can
only be supplied during the specified period of time.
Priority
Use the pull-down menu to select the priority of the PoE ports. Port priority determines the
priority which the system attempts to supply the power to the ports. There are three levels of
priority that can be selected, critical, high, and low. When multiple ports happen to have the
same level of priority, the port ID will be used to determine the priority. The lower port ID has
higher priority. The setting of priority will affect the order of supplying power. Whether the
disconnect method is set to deny low priority port, the priority of each port will be used by the
system to manage the supply of power to ports.
Power Limit
This function is used to configure the per-port power limit. If a port exceeds its power limit, it
will shut down.
Based on 802.3af/802.3at, there are different PD classes and power consumption ranges;
Class 0 – 0.44~12.95W
Class 1 – 0.44~3.84W
Class 2 – 3.84~6.49W
Class 3 – 6.49~12.95W
Class 4 – 12.95W~29.5W (only ports 1~8)
The following is the power limit applied to the port for these five classes. For each class, the
power limit is a little more than the power consumption range for that class. This takes into
account any power loss on the cable. Thus, the following are the typical values;
Class 0 : 15400mW
Class 1 : 4000mW
Class 2 : 7000mW
Class 3 : 15400mW
User define: 35000mW (15400~35000 only applies to ports 1~8)
As well as these four pre-defined settings, users can directly specify any value ranging from
1000mW to 35000mW on port 1~8 and 1000mW~15400mW on port 9~24.
NOTE: DES-3528P ports 1~8 can support PoE up to 35W by configuring the PoE port user
define value, also all ports can support 802.3af (1000~15400mW).
Click Apply to implement changes made. The port status of all PoE configured ports is displayed in the table in the
bottom half of the screen shown above.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
45
SNMP Settings
Simple Network Management Protocol (SNMP) is an OSI Layer 7 (Application Layer) designed specifically for
managing and monitoring network devices. SNMP enables network management stations to read and modify the
settings of gateways, routers, switches, and other network devices. Use SNMP to configure system features for proper
operation, monitor performance and detect potential problems in the Switch, switch group or network.
Managed devices that support SNMP include software (referred to as an agent), which runs locally on the device. A
defined set of variables (managed objects) is maintained by the SNMP agent and used to manage the device. These
objects are defined in a Management Information Base (MIB), which provides a standard presentation of the
information controlled by the on-board SNMP agent. SNMP defines both the format of the MIB specifications and the
protocol used to access this information over the network.
The DES-3528/DES-3552 Series supports the SNMP versions 1, 2c, and 3. The default SNMP setting is disabled.
You must enable SNMP. Once SNMP is enabled you can choose which version you want to use to monitor and
control the Switch. The three versions of SNMP vary in the level of security provided between the management station
and the network device.
In SNMP v.1 and v.2, user authentication is accomplished using 'community strings', which function like passwords.
The remote user SNMP application and the Switch SNMP must use the same community string. SNMP packets from
any station that has not been authenticated are ignored (dropped).
The default community strings for the Switch used for SNMP v.1 and v.2 management access are:
•
public - Allows authorized management stations to retrieve MIB objects.
•
private - Allows authorized management stations to retrieve and modify MIB objects.
SNMPv3 uses a more sophisticated authentication process that is separated into two parts. The first part is to
maintain a list of users and their attributes that are allowed to act as SNMP managers. The second part describes
what each user on that list can do as an SNMP manager.
The Switch allows groups of users to be listed and configured with a shared set of privileges. The SNMP version may
also be set for a listed group of SNMP managers. Thus, you may create a group of SNMP managers that are allowed
to view read-only information or receive traps using SNMPv1 while assigning a higher level of security to another
group, granting read/write privileges using SNMPv3.
Using SNMPv3 individual users or groups of SNMP managers can be allowed to perform or be restricted from
performing specific SNMP management functions. The functions allowed or restricted are defined using the Object
Identifier (OID) associated with a specific MIB. An additional layer of security is available for SNMPv3 in that SNMP
messages may be encrypted. To read more about how to configure SNMPv3 settings for the Switch read the next
section.
Traps
Traps are messages that alert network personnel of events that occur on the Switch. The events can be as serious as
a reboot (someone accidentally turned OFF the Switch), or less serious like a port status change. The Switch
generates traps and sends them to the trap recipient (or network manager). Typical traps include trap messages for
Authentication Failure, Topology Change and Broadcast\Multicast Storm.
MIBs
The Switch in the Management Information Base (MIB) stores management and counter information. The Switch uses
the standard MIB-II Management Information Base module. Consequently, values for MIB objects can be retrieved
from any SNMP-based network management software. In addition to the standard MIB-II, the Switch also supports its
own proprietary enterprise MIB as an extended Management Information Base. Specifying the MIB Object Identifier
may also retrieve the proprietary MIB. MIB values can be either read-only or read-write.
The DES-3528/DES-3552 Series incorporates a flexible SNMP management for the switching environment. SNMP
management can be customized to suit the needs of the networks and the preferences of the network administrator.
Use the SNMP V3 menus to select the SNMP version used for specific tasks.
The DES-3528/DES-3552 Series supports the Simple Network Management Protocol (SNMP) versions 1, 2c, and 3.
The administrator can specify the SNMP version used to monitor and control the Switch. The three versions of SNMP
vary in the level of security provided between the management station and the network device.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
46
SNMP settings are configured using the menus located on the SNMP V3 folder of the web manager. Workstations on
the network that are given SNMP access privileged to the Switch can be restricted with the Security > Trusted Host
window.
SNMP Global Settings
Use this table to globally enable or disable the SNMP Settings on the switch. To view this window, click
Configuration > SNMP Settings > SNMP Global Settings:
Figure 2 - 37 SNMP Global Settings window
SNMP View Table
This window is used to assign views to community strings that define which MIB objects can be accessed by a remote
SNMP manager. To configure SNMP View Settings for the Switch, click Configuration > SNMP Settings > SNMP
View Table
Figure 2 - 38 SNMP View Table window
The following parameters can be set:
Parameter Description
View Name
Type an alphanumeric string of up to 32 characters. This is used to identify the new SNMP
view being created.
Subtree OID
Type the Object Identifier (OID) Subtree for the view. The OID identifies an object tree (MIB
tree) that will be included or excluded from access by an SNMP manager.
View Type
Select Included to include this object in the list of objects that an SNMP manager can
access. Select Excluded to exclude this object from the list of objects that an SNMP
manager can access.
To implement your new settings, click Apply. To delete an entry click the corresponding Delete button.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
47
SNMP Group Table
An SNMP Group created with this table maps SNMP users (identified in the SNMP User Table) to the views created in
the previous menu. To view this window, click Configuration > SNMP Settings > SNMP Group Table:
Figure 2 - 39 SNMP Group Table window
To delete an existing SNMP Group Table entry, click the corresponding Delete button.
The following parameters can be set:
Parameter
Description
Group Name
Type an alphanumeric string of up to 32 characters. This is used to identify the new SNMP
group of SNMP users.
Read View Name
This name is used to specify the SNMP group created can request SNMP messages.
Write View Name
Specify a SNMP group name for users that are allowed SNMP write privileges to the Switch's
SNMP agent.
Notify View Name
Specify a SNMP group name for users that can receive SNMP trap messages generated by
the Switch's SNMP agent.
User-based
Security Model
SNMPv1 - Specifies that SNMP version 1 will be used.
SNMPv2 - Specifies that SNMP version 2c will be used. The SNMPv2 supports both
centralized and distributed network management strategies. It includes improvements in the
Structure of Management Information (SMI) and adds some security features.
SNMPv3 - Specifies that the SNMP version 3 will be used. SNMPv3 provides secure access
to devices through a combination of authentication and encrypting packets over the network.
Security Level
The Security Level settings only apply to SNMPv3.
NoAuthNoPriv - Specifies that there will be no authorization and no encryption of packets sent
between the Switch and a remote SNMP manager.
AuthNoPriv - Specifies that authorization will be required, but there will be no encryption of
packets sent between the Switch and a remote SNMP manager.
AuthPriv - Specifies that authorization will be required, and that packets sent between the
Switch and a remote SNMP manger will be encrypted.
To implement the new settings, click Apply.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
48
SNMP User Table
This window displays all of the SNMP User's currently configured on the Switch and also allows you to add new users.
To view this window, click Configuration > SNMP Settings > SNMP User Table:
Figure 2 - 40 SNMP User Table window
To delete an existing SNMP User Table entry, click the corresponding Delete button.
The following parameters may be set:
Parameter Description
User Name
An alphanumeric string of up to 32 characters. This is used to identify the SNMP users.
Group Name
This name is used to specify the SNMP group created can request SNMP messages.
SNMP Version
V1 - Indicates that SNMP version 1 is in use.
V2 - Indicates that SNMP version 2 is in use.
V3 - Indicates that SNMP version 3 is in use.
SNMP V3 Encryption
None – Indicates that there is no SNMP V3 Encryption
Password – Indicates that there is SNMP V3 Encryption through a password
Key – Indicates that there is SNMP V3 Encryption through a key.
Auth-Protocol by
Password
MD5 - Indicates that the HMAC-MD5-96 authentication level will be used.
SHA - Indicates that the HMAC-SHA authentication protocol will be used.
Priv-Protocol by
Password
None - Indicates that no authorization protocol is in use.
DES - Indicates that DES 56-bit encryption is in use based on the CBC-DES (DES-56)
standard.
Auth-Protocol by Key
MD5 - Indicates that the HMAC-MD5-96 authentication level will be used.
SHA - Indicates that the HMAC-SHA authentication protocol will be used.
Priv-Protocol by Key
None - Indicates that no authorization protocol is in use.
DES - Indicates that DES 56-bit encryption is in use based on the CBC-DES (DES-56)
standard.
Password
Enter a Password when SNMP V3 Encryption is enabled for Password mode.
Key
Enter a Key when SNMP V3 Encryption is enabled for Key mode.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
49
To implement changes made, click Apply.
SNMP Community Table
Use this table to view existing SNMP Community Table configurations and to create a SNMP community string to
define the relationship between the SNMP manager and an agent. The community string acts like a password to
permit access to the agent on the Switch. One or more of the following characteristics can be associated with the
community string:
An Access List of IP addresses of SNMP managers that are permitted to use the community string to gain access to
the Switch's SNMP agent.
Any MIB view that defines the subset of all MIB objects will be accessible to the SNMP community.
Read/write or read-only level permission for the MIB objects accessible to the SNMP community.
To configure SNMP Community entries, click Configuration > SNMP Settings > SNMP Community Table
Figure 2 - 41 SNMP Community Table window
The following parameters can set:
Parameter Description
Community Name
Type an alphanumeric string of up to 32 characters that is used to identify members of an
SNMP community. This string is used like a password to give remote SNMP managers
access to MIB objects in the Switch's SNMP agent.
View Name
Type an alphanumeric string of up to 32 characters that is used to identify the group of MIB
objects that a remote SNMP manager is allowed to access on the Switch. The view name
must exist in the SNMP View Table.
Access Right
Read Only - Specifies that SNMP community members using the community string created
can only read the contents of the MIBs on the Switch.
Read Write - Specifies that SNMP community members using the community string created
can read from, and write to the contents of the MIBs on the Switch.
To implement the new settings, click Apply. To delete an entry from the SNMP Community Table, click the
corresponding Delete button.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
50
SNMP Host Table
Use the SNMP H ost T able window to set up SNMP trap recipients. To configure SNMP Host Table entries, click
Configuration > SNMP Settings > SNMP Host Table
Figure 2 - 42 SNMP Host Table window
The following parameters can set:
Parameter Description
Host IP Address
Type the IP address of the remote management station that will serve as the SNMP host
for the Switch.
User-based Security
Model
SNMPv1 - Specifies that SNMP version 1 will be used.
SNMPV2c - Specifies that SNMP version 2 will be used.
SNMPV3 - To specify that the SNMP version 3 will be used.
Security Level
NoAuthNoPriv – To specify a NoAuthNoPriv security level.
AuthNoPriv - To specify an AuthNoPriv security level.
AuthPriv - To specify an AuthPriv security level.
Community String/
SNMPv3 User Name
Type in the community string or SNMPv3 user name as appropriate.
To implement your new settings, click Apply.
SNMP Engine ID
The Engine ID is a unique identifier used for SNMP V3 implementations. This is an alphanumeric string used to
identify the SNMP engine on the Switch. To display the Switch's SNMP Engine ID, click Configuration > S NMP
Settings > SNMP Engine ID
Figure 2 - 43 SNMP Engine ID window
To change the Engine ID, enter the new Engine ID in the space provided and click the Apply button.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
51
SNMP Trap Configuration
The following window is used to enable and disable trap settings for the SNMP function on the Switch. To view this
window for configuration, click Configuration > SNMP Settings > SNMP Trap Configuration
Figure 2 - 44 SNMP Trap Configuration window
To enable or disable the Traps State and/or the Authenticate Traps State, use the corresponding pull-down menu to
change and click Apply.
sFlow
The sFlow folder contains four windows to enable and configure the sFlow settings on the Switch. sFlow is a
technology for monitoring traffic in data networks containing switches and routers. The sFlow monitoring system
consists of an sFlow Agent (embedded in a switch or router or in a standalone probe) and a central sFlow Collector.
The architecture and sampling techniques used in the sFlow monitoring system were designed for providing
continuous site-wide (and enterprise-wide) traffic monitoring of high speed switched and routed networks.
sFlow Global State Settings
This table is used to enable or disable the sFlow Global State Settings on the Switch. The sFlow version, address and
state configurations can also be viewed in this table.
To view this window, click Configuration > sFlow > sFlow Global State Settings as shown below:
Figure 2 - 45 sFlow Global State Settings window
Select Disabled or Enabled and click Apply.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
52
sFlow Analyzer Server Settings
This window is used to configure the sFlow analyzer server settings. You can specify more than one analyzer server
with the same IP address but with different UDP port numbers. You can have up to four unique combinations of IP
address and UDP port numbers.
To view this window, click Configuration > sFlow > sFlow Analyzer Server Settings as shown below:
Figure 2 - 46 sFlow Analyzer Server Settings window
The following parameters can be configured:
Parameter
Description
Analyzer Server I D ( 1-
4)
Up to four sFlow Analyzer Servers can be configured.
Owner Name
The description about the sFlow analyzer server(s). When owner is set or modified, the
timeout value will become 400 automatically.
Timeout (1-2000000)
The length of time before the server is timed out. When the analyzer server times out, all
of the flow samplers and counter pollers associated with this analyzer server will be
deleted. “Infinite” indicates that the analyzer server will never time out. If not specified, the
default value is 400.
Collector Address
The IP address of the analyzer server. If not specified, the address will be 0.0.0.0 which
means that the entry will be inactive.
Collector
Port (1
-
65535)
The destination UDP port for sending the sFlow datagrams. If not specified, the default
value is 6343.
Max
Datagram
size
(300-1400)
The maximum number of data bytes that can be packed in a single sample datagram. If not
specified, the default value is 1400.
Click Apply to implement the changes made.
sFlow Flow Sampler Settings
This table is used to create sFlow flow sampler settings on the Switch. By configuring the sampling function for a port,
a sample packet received by this port will be encapsulated and forwarded to the analyzer server at the specified
interval.
To view this window, click Configuration > sFlow > sFlow Flow Sampler Settings as shown below:
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
53
Figure 2 - 47 sFlow Flow Sampler Settings window
The following parameters can be configured:
Parameter Description
From Port / To Port
Specifies the port or list of ports to be configured.
Analyzer Server I D (1-
4)
The analyzer server id specifies the ID of a server analyzer where the packet will be
forwarded.
Rate (0-65535)
The sampling rate for packet sampling. The actual rate is the configured rate value
multiplied by 256. For example, if the rate is 20, the actual rate 5120. One packet will be
sampled from every 5120 packets. If set to 0, the sampler is disabled.
MAX Header Size (18-
256)
The maximum number of leading bytes in the packet which will be sampled, encapsulated
and forwarded to the server.
Click Apply to implement the changes made.
sFlow Counter Poller Settings
This window is used to create the sflow counter poller settings on the Switch. Within the sflow counter poller function,
the port statistics counter information will be forwarded to the server at the configured interval. These counters are
RFC 2233 counters.
To view this window, click Configuration > sFlow > sFlow Counter Poller Settings as shown below:
Figure 2 - 48 sFlow Counter Poller Settings window
The following parameters can be configured:
Parameter
Description
From Port / To Port
Specifies the port or list of ports to be configured.
Analyzer Server I D ( 1-
4)
The analyzer server id specifies the ID of a server analyzer where the packet will be
forwarded.
Interval (20-120)
Specifies the maximum number of seconds between successive statistic counter
information. To disable the interval, check the Disabled box.
Click Apply to implement the changes made.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
54
Stacking
From firmware release v2.00 of this Switch, the DES-3528/DES-3552 Series now supports switch stacking, where a
set of eight switches can be combined to be managed by one IP address through Telnet, the GUI interface (web), the
console port or through SNMP. Each switch of this series has two stacking ports located at the rear of the device,
which can be used to connect stacking enabled devices and make them stack together. After adding these stacking
ports, the user may connect these ports together using copper ables (also sold separately) in one of two possible
topologies.
Duplex C hain – As shown in Figure 2 - 49, The Duplex Chain topology stacks switches together in a chain-link
format. Using this method, data transfer is only possible in one direction and if there is a break in the chain, then data
transfer will obviously be affected.
Duplex Ring – As shown in Figure 2 - 50, the Duplex Ring stacks switches in a ring or circle format where data can
be transferred in two directions. This topology is very resilient due to the fact that if there is a break in the ring, data
can still be transferred through the stacking cables between switches in the stack.
Figure 2 - 49 Switches stacked in a Duplex Chain
Figure 2 - 50 Switches stacked in a Duplex Ring
Within each of these topologies, each switch plays a role in the Switch stack. These roles can be set by the user per
individual Switch, or if desired, can be automatically determined by the Switch stack. Three possible roles exist when
stacking with the DES-3528/DES-3552 Series.
NOTE: Only ports 27 and 28 of the DES-3528 Series, or ports 51 and ports 52 of DES-
3552 support stacking. The other ports cannot be used for stacking. For a stacking
disabled device, ports 27 and 28 of the DES-3528 Series, or ports 51 and ports 52 of
DES-3552 can be used as normal GE ports.
Primary Master – The Primary Master is the leader of the stack. It will maintain normal operations, monitor operations
and the running topology of the Stack. This switch will also assign Stack Unit IDs, synchronize configurations and
transmit commands to remaining switches in the switch stack. The Primary Master can be manually set by assigning
this Switch the highest priority (a lower number denotes a higher priority) before physically assembling the stack, or it
can be determined automatically by the stack through an election process which determines the lowest MAC address
and then will assign that switch as the Primary Master, if all priorities are the same. The Primary master are physically
displayed by the seven segment LED to the far right on the front panel of the switch where this LED will flash between
its given Box ID and ‘H’.
Backup M aster – The Backup Master is the backup to the Primary Master, and will take over the functions of the
Primary Master if the Primary Master fails or is removed from the Stack. It also monitors the status of neighboring
switches in the stack, will perform commands assigned to it by the Primary Master and will monitor the running status
of the Primary Master. The Backup Master can be set by the user by assigning this Switch the second highest priority
before physically assembling the stack, or it can be determined automatically by the stack through an election process
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
55
which determines the second lowest MAC address and then will assign that switch as the Backup Master, if all
priorities are the same.
Slave – Slave switches constitute the rest of the switch stack and although not Primary or Backup Masters, they can
be placed into these roles when these other two roles fail or are removed from the stack. Slave switches perform
operations requested by the master, monitor the status of neighbor switches in the stack and the stack topology and
adhere to the Backup Master’s commands once it becomes a Primary Master. Slave switches will do a self-check to
determine if it is to become the Backup Master if the Backup Master is promoted to the Primary Master, or if the
Backup Master fails or is removed from the switch stack. If both Primary and Backup masters fail, or are removed from
the Switch stack, it will determine if it is to become the Primary Master. These roles will be determined, first by priority
and if the priority is the same, the lowest MAC address.
Once switches have been assembled in the topology desired by the user and powered on, the stack will undergo three
processes until it reaches a functioning state.
Initialization State – This is the first state of the stack, where the runtime codes are set and initialized and the system
conducts a peripheral diagnosis to determine each individual switch is functioning properly.
Master Election State – Once the codes are loaded and initialized, the stack will undergo the Master Election State
where it will discover the type of topology used, elect a Primary Master and then a Backup Master.
Synchronization S tate – Once the Primary Master and the Backup Master have been established, the Primary
Master will assign Stacking Unit IDs to switches in the stack, synchronize configurations for all switches and then
transmit commands to the rest of the switches based on the users configurations of the Primary Master.
Once these steps have been completed, the switch stack will enter a normal operating mode.
Stack Switch Swapping
The stacking feature of the DES-3528/DES-3552 Series supports “hot swapping” of switches in and out of the running
stack. Users may remove or add switches to the stack without powering down or largely affecting the transfer of data
between switches in the stack, with a few minor provisions.
When switches are “hot inserted” into the running stack, the new switch may take on the Primary Master, Backup
Master or Slave role, depending on configurations set on the newly added switch, such as configured priority or MAC
address. Yet, if adding two stacks together that have both previously undergone the election process, and therefore
both have a Primary Master and a Backup master, a new Primary Master will be elected from one of the already
existing Primary Masters, based on priority or MAC address. This Primary Master will take over all of the Primary
Master’s roles for all new switches that were hot inserted. This process is done using discovery packets that circulate
through the switch stack every 1.5 seconds until the discovery process has been completed.
The “hot remove” action means removing a device from the stack while the stack is still running. The hot removal is
detected by the stack when it fails to receive heartbeat packets during its specified interval from a device, or when one
of the stacking ports links is down. Once the device has been removed, the remaining switches will update their
stacking topology database to reflect the change. Any one of the three roles, Primary Master, Backup Master or Slave,
may be removed from the stack, yet different processes occur for each specific device removal.
If a Slave device has been removed, the Primary Master will inform other switches of the hot remove of this device
through the use of unit leave messages. Switches in the stack will clear the configurations of the unit removed, and
dynamically learned databases, such as ARP, will be cleared as well.
If the Backup Master has been hot removed, a new Backup Master will be chosen through the election process
previously described. Switches in the stack will clear the configurations of the unit removed, and dynamically learned
databases, such as ARP, will be cleared as well. Then the Backup Master will begin backing up the Primary Master
when the database synchronization has been completed by the stack.
If the Primary Master is removed, the Backup Master will assume the Primary Master’s role and a new Backup Master
will be chosen using the election process. Switches in the stack will clear the configurations of the unit removed, and
dynamically learned databases, such as ARP, will be cleared as well. The new Primary Master will inherit the MAC
and IP address of the previous Primary Master to avoid conflict within the stack and the network itself.
If both the Primary Master and the Backup Master are removed, the election process is immediately processed and a
new Primary Master and Backup Master is determined. Switches in the stack will clear the configurations of the units
removed, and dynamically learned databases, such as ARP, will be cleared as well. Static switch configurations still
remain in the database of the remaining switches in the stack and those functions will not be affected.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
56
NOTE: If there is a Box ID conflict when the stack is in the discovery phase, the device
will enter a special standalone topology mode. Users can only get device information,
configure Box IDs, save and reboot. All stacking ports will be disabled and an error
message will be produced on the local console port of each device in the stack. Users
must reconfigure Box IDs and reboot the stack.
Stacking Mode Settings
This window is to enable the switch stack (up to 8) and configure the priority of the stacking boxes.
To open this window, click Configuration > Stacking Mode Settings
Figure 2 - 51 Stacking Mode Settings window
The following parameters can be configured:
Parameter
Description
Stacking Mode
Click Enabled or Disabled to enable or disable the stacking function.
Current Box ID
Use the dorp-down menu to identify the Switch being configured. The box ID is 1 – 8.
New Box ID
Use the drop-down menu to assign a new box ID to the Switch. The new box ID is Auto, or
1 – 8.
Priority (1-63)
Enter a number to assign a priority value to the box, with lower numbers having higher
priority. The possible priority range is 1 – 63.
Time Range Settings
The Time Range window is used in conjunction with the Access Profile feature to determine a starting point and an
ending point, based on days of the week, when an Access Profile configuration will be enabled on the Switch. Once
configured here, the time range settings are to be applied to an access profile rule using the Access Profile table. The
user may enter up to 64 time range entries on the Switch.
To open this window, click Configuration > Time Range Settings
Figure 2 - 52 Time Range Settings window
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
57
Single IP Management
Simply put, D-Link Single IP Management is a concept that will stack switches together over Ethernet instead of using
stacking ports or modules. There are some advantages in implementing the "Single IP Management" feature:
1. SIM can simplify management of small workgroups or wiring closets while scaling the network to handle
increased bandwidth demand.
2. SIM can reduce the number of IP address needed in your network.
3. SIM can eliminate any specialized cables for stacking connectivity and remove the distance barriers that
typically limit your topology options when using other stacking technology.
Switches using D-Link Single IP Management (labeled here as SIM) must conform to the following rules:
SIM is an optional feature on the Switch and can easily be enabled or disabled through the Command Line Interface
or Web Interface. SIM grouping has no effect on the normal operation of the Switch in the user's network.
There are three classifications for SIM. The Commander Switch (CS), which is the master switch of the group,
Member Switch (MS), which is a switch that is recognized by the CS a member of a SIM group, and a Candidate
Switch (CaS), which is a Switch that has a physical link to the SIM group but has not been recognized by the CS as a
member of the SIM group.
A SIM group can only have one Commander Switch (CS).
All switches in a particular SIM group must be in the same IP subnet (broadcast domain). Members of a SIM group
cannot cross a router.
A SIM group accepts up to 33 switches (numbered 0-32), including the Commander Switch (numbered 0).
There is no limit to the number of SIM groups in the same IP subnet (broadcast domain), however a single switch can
only belong to one group.
If multiple VLANs are configured, the SIM group will only utilize the system VLAN on any switch.
SIM allows intermediate devices that do not support SIM. This enables the user to manage switches that are more
than one hop away from the CS.
The SIM group is a group of switches that are managed as a single entity. SIM switches may take on three different
roles:
1. Commander Switch (CS) - This is a switch that has been manually configured as the controlling device for a
group, and takes on the following characteristics:
It has an IP Address.
It is not a commander switch or member switch of another Single IP group.
It is connected to the member switches through its management VLAN.
2. Member Switch (MS) - This is a switch that has joined a single IP group and is accessible from the CS, and it
takes on the following characteristics:
It is not a CS or MS of another Single IP group.
It is connected to the CS through the CS management VLAN.
3. Candidate Switch (CaS) - This is a switch that is ready to join a SIM group but is not yet a member of the
SIM group. The Candidate Switch may join the SIM group of a switch by manually configuring it to be a MS of
a SIM group. A switch configured as a CaS is not a member of a SIM group and will take on the following
characteristics:
It is not a CS or MS of another Single IP group.
It is connected to the CS through the CS management VLAN
After configuring one switch to operate as the CS of a SIM group, additional switches may join the group through a
direct connection to the Commander switch. Only the Commander switch will allow entry to the candidate switch
enabled for SIM. The CS will then serve as the in band entry point for access to the MS. The CS's IP address will
become the path to all MS's of the group and the CS's Administrator's password, and/or authentication will control
access to all MS's of the SIM group.
With SIM enabled, the applications in the CS will redirect the packet instead of executing the packets. The
applications will decode the packet from the administrator, modify some data, then send it to the MS. After execution,
the CS may receive a response packet from the MS, which it will encode and send it back to the administrator.
When a CS becomes a MS, it automatically becomes a member of the first SNMP community (include read/write and
read only) to which the CS belongs. However, if a MS has its own IP address, it can belong to SNMP communities to
which other switches in the group, including the CS, do not belong.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
58
The Upgrade to v1.6
To better improve SIM management, the DES-3528/DES-3552 Series has been upgraded to version 1.6 in this
release. Many improvements have been made, including:
1. The Commander Switch (CS) now has the capability to automatically rediscover member switches that have left
the SIM group, either through a reboot or web malfunction. This feature is accomplished through the use of Discover
packets and Maintain packets that previously set SIM members will emit after a reboot. Once a MS has had its MAC
address and password saved to the CS’s database, if a reboot occurs in the MS, the CS will keep this MS information
in its database and when a MS has been rediscovered, it will add the MS back into the SIM tree automatically. No
configuration will be necessary to rediscover these switches.
There are some instances where pre-saved MS switches cannot be rediscovered. For example, if the Switch is still
powered down, if it has become the member of another group, or if it has been configured to be a Commander Switch,
the rediscovery process cannot occur.
3. This version will support multiple switch upload and downloads for firmware, configuration files and log files, as
follows:
•
Firmware – The switch now supports multiple MS firmware downloads from a TFTP server.
•
Configuration F iles – This switch now supports multiple downloading and uploading of configuration files
both to (for configuration restoration) and from (for configuration backup) MS’s, using a TFTP server.
•
Log – The switch now supports uploading multiple MS log files to a TFTP server.
4. The user may zoom in and zoom out when utilizing the topology window to get a better, more defined view of the
configurations.
Single IP Settings
All switches are set as Candidate (CaS) switches as their factory default configuration and Single IP Management will
be disabled. To enable SIM for the Switch using the Web interface, click Configuration > Single IP Managemnet >
Single IP Settings which will reveal the following window:
Figure 2 - 53 Single IP Settings window (disabled)
Change the SIM State to Enabled, and the Role State to Commander using the pull-down menu and click Apply.
2. The topology map now includes new features for connections that are a
member of a port trunking group. It will display the speed and number of
Ethernet connections creating this port trunk group, as shown in the
adjacent picture.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
59
Figure 2 - 54 Single IP Settings window (enabled)
The following parameters can be set:
Parameters Description
SIM State
Use the pull-down menu to either enable or disable the SIM state on the Switch. Disabled will
render all SIM functions on the Switch inoperable.
Role State
Use the pull-down menu to change the SIM role of the Switch. The two choices are:
Candidate - A Candidate Switch (CaS) is not the member of a SIM group but is connected to a
Commander Switch. This is the default setting for the SIM role.
Commander - Choosing this parameter will make the Switch a Commander Switch (CS). The
user may join other switches to this Switch, over Ethernet, to be part of its SIM group. Choosing
this option will also enable the Switch to be configured for SIM.
Group Name
The user may enter a name for the group.
Discovery
Interval (30-90)
The user may set the discovery protocol interval, in seconds that the Switch will send out
discovery packets. Returning information to a Commander Switch will include information about
other switches connected to it. (Ex. MS, CaS). The user may set the Discovery Interval from 30
to 90 seconds.
Hold T ime C ount
(100-255)
This parameter may be set for the time, in seconds the Switch will hold information sent to it
from other switches, utilizing the Discovery Interval. The user may set the hold time from 100
to 255 seconds.
Click Apply to implement the settings.
After enabling the Switch to be a Commander Switch (CS), the Single IP Management folder will then contain four
added links to aid the user in configuring SIM through the web, including Topology, Firmware Upgrade and
Configuration Backup/Restore and Upload Log File.
Topology
The Topology window will be used to configure and manage the Switch within the SIM group and requires Java script
to function properly on your computer.
The Java Runtime Environment on your server should initiate and lead you to the topology window, as seen below.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
60
Figure 2 - 55 Single IP Management window - Tree View
The Tree View window holds the following information under the Data tab:
Parameter Description
Device Name
This field will display the Device Name of the switches in the SIM group configured by the user. If
no Device Name is configured by the name, it will be given the name default and tagged with the
last six digits of the MAC Address to identify it.
Remote Port
Displays the number of the physical port on the CS that the MS or CaS is connected to. The CS
will have no entry in this field.
Speed
Displays the connection speed between the CS and the MS or CaS.
Local Port
Displays the number of the physical port on the MS or CaS that the CS is connected to. The CS
will have no entry in this field.
MAC Address
Displays the MAC address of the corresponding Switch.
Model Name
Displays the full model name of the corresponding Switch.
To view the Topology Map, click the View menu in the toolbar and then Topology, which will produce the following
window. The Topology View will refresh itself periodically (20 seconds by default).
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
61
Figure 2 - 56 Topology view
This window will display how the devices within the Single IP Management Group are connected to other groups and
devices. Possible icons in this screen are as follows:
Icon Description
Group
Layer 2 commander switch
Layer 3 commander switch
Commander switch of other group
Layer 2 member switch.
Layer 3 member switch
Member switch of other group
Layer 2 candidate switch
Layer 3 candidate switch
Unknown device
Non-SIM devices
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
62
Tool Tips
In the Topology view window, the mouse plays an important role in configuration and in viewing device information.
Setting the mouse cursor over a specific device in the topology window (tool tip) will display the same information
about a specific device as the Tree view does. See the window below for an example.
Figure 2 - 57 Device Information Utilizing the Tool Tip
Setting the mouse cursor over a line between two devices will display the connection speed between the two devices,
as shown below.
Figure 2 - 58 Port Speed Utilizing the Tool Tip
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
63
Right-Click
Right-clicking on a device will allow the user to perform various functions, depending on the role of the Switch in the
SIM group and the icon associated with it.
Group Icon
Figure 2 - 59 Right-Clicking a Group Icon
Figure 2 - 60 Figure 6- 7. Property window
This window holds the following information:
Parameter Description
Device Name
This field will display the Device Name of the switches in the SIM group configured by the user.
If no Device Name is configured by the name, it will be given the name default and tagged with
the last six digits of the MAC Address to identify it.
Module Name
Displays the full module name of the switch that was right-clicked.
MAC Address
Displays the MAC Address of the corresponding Switch.
Local Port No.
Displays the number of the physical port on the MS or CaS that the CS is connected to. The CS
will have no entry in this field.
Remote Port No.
Displays the number of the physical port on the CS that the MS or CaS is connected to. The CS
will have no entry in this field.
Port Speed
Displays the connection speed between the CS and the MS or CaS
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
64
Click Close to close the Property window.
Commander Switch Icon
Figure 2 - 61 Right-Clicking a Commander Icon
The following options may appear for the user to configure:
Collapse - To collapse the group that will be represented by a single icon.
Expand - To expand the SIM group, in detail.
Property - To pop up a window to display the group information.
Member Switch Icon
Figure 2 - 62 Right-Clicking a Member icon
The following options may appear for the user to configure:
Collapse - To collapse the group that will be represented by a single icon.
Expand - To expand the SIM group, in detail.
Remove from group - Remove a member from a group.
Configure - Launch the web management to configure the Switch.
Property - To pop up a window to display the device information.
Candidate Switch Icon
Figure 2 - 63 Right-Clicking a Candidate icon
The following options may appear for the user to configure:
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
65
Collapse - To collapse the group that will be represented by a single icon.
Expand - To expand the SIM group, in detail.
Add to group - Add a candidate to a group. Clicking this option will reveal the following dialog for the user to enter a
password for authentication from the Candidate Switch before being added to the SIM group. Click OK to enter the
password or Cancel to exit the window.
Figure 2 - 64 Input password window
Property - To pop up a window to display the device information, as shown below.
Menu Bar
The Single IP Management window contains a menu bar for device configurations, as seen below.
Figure 2 - 65 Menu Bar of the Topology View
The five menus on the menu bar are as follows.
File
Print Setup - Will view the image to be printed.
Print Topology - Will print the topology map.
Preference - Will set display properties, such as polling interval, and the views to open at SIM startup.
Group
Add to group - Add a candidate to a group. Clicking this option will reveal the following dialog for the user to enter a
password for authentication from the Candidate Switch before being added to the SIM group. Click OK to enter the
password or Cancel to exit the window.
Figure 2 - 66 Input password window
Remove from Group - Remove an MS from the group.
Device
Configure - Will open the web manager for the specific device.
View
Refresh - Update the views with the latest status.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
66
Topology - Display the Topology view.
Help
About - Will display the SIM information, including the current SIM version.
Figure 2 - 67 About window
Firmware Upgrade
This screen is used to upgrade firmware from the Commander Switch to the Member Switch. Member Switches will be
listed in the table and will be specified by Port (port on the CS where the MS resides), MAC Address, Model Name
and Version. To specify a certain Switch for firmware download, click its corresponding check box under the Port
heading. To update the firmware, enter the Server I P Address where the firmware resides and enter the
Path/Filename of the firmware. Click Download to initiate the file transfer. To access the following window, click
Configuration > Single IP Management > Firmware Upgrade
Figure 2 - 68 Firmware Upgrade window
Configuration File Backup/Restore
This screen is used to upgrade configuration files from the Commander Switch to the Member Switch using a TFTP
server. Member Switches will be listed in the table and will be specified by ID, Port (port on the CS where the MS
resides), MAC Address, Model Name and Firmware Version. To update the configuration file, enter the Server IP
Address where the file resides and enter the Path/Filename of the configuration file. Click Restore to initiate the file
transfer from a TFTP server to the Switch. Click Backup to backup the configuration file to a TFTP server. To access
the following window, click Configuration > Single IP Management > Configuration File Backup/Restore
Figure 2 - 69 Configuration File Backup/Restore window
Upload Log File
The following window is used to upload log files from SIM member switches to a specified PC. To upload a log file,
enter the Server IP address of the SIM member switch and then enter a Path\Filename on your PC where you wish to
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
67
save this file. Click Upload to initiate the file transfer. To view this window click Configuration > Single IP
Management > Upload Log File
Figure 2 - 70 Upload Log File window
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
68
Section 3
L2 Features
Jumbo Frame
802.1Q VLAN
Voice VLAN
Subnet VLAN
QinQ
802.1v Protocol VLAN
RSPAN Settings
GVRP Settings
GVRP Timer Settings
Asymmetric VLAN Settings
MAC-based VLAN Settings
PVID Auto Assign Settings
VLAN Trunk Settings
Port Trunking
LACP Port Settings
Traffic Segmentation
IGMP Snooping
MLD Snooping Settings
Port Mirror
Loopback Detection Settings
BPDU Attack Protection Settings
Spanning Tree
Forwarding & Filtering
LLDP
CFM
Ethernet OAM
The following section will aid the user in configuring Layer 2 functions for the Switch. The Switch includes various
functions all discussed in detail in the following section.
Jumbo Frame
This window will enable or disable the Jumbo Frame function on the Switch. The default is Disabled. When enabled,
jumbo frame (frames larger than the standard Ethernet frame size of 1536 bytes) of up to 9K can be transmitted by the
Switch. To view this window click L2 Features > Jumbo Frame
Figure 3 - 1 Jumbo Frame window
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
69
Click Apply to implement changes made.
VLANs
Understanding IEEE 802.1p Priority
Priority tagging is a function defined by the IEEE 802.1p standard designed to provide a means of managing traffic on
a network where many different types of data may be transmitted simultaneously. It is intended to alleviate problems
associated with the delivery of time critical data over congested networks. The quality of applications that are
dependent on such time critical data, such as video conferencing, can be severely and adversely affected by even
very small delays in transmission.
Network devices that are in compliance with the IEEE 802.1p standard have the ability to recognize the priority level of
data packets. These devices can also assign a priority label or tag to packets. Compliant devices can also strip priority
tags from packets. This priority tag determines the packet's degree of expeditiousness and determines the queue to
which it will be assigned.
Priority tags are given values from 0 to 7 with 0 being assigned to the lowest priority data and 7 assigned to the
highest. The highest priority tag 7 is generally only used for data associated with video or audio applications, which
are sensitive to even slight delays, or for data from specified end users whose data transmissions warrant special
consideration.
The Switch allows you to further tailor how priority tagged data packets are handled on your network. Using queues to
manage priority tagged data allows you to specify its relative priority to suit the needs of your network. There may be
circumstances where it would be advantageous to group two or more differently tagged packets into the same queue.
Generally, however, it is recommended that the highest priority queue, Queue 7, be reserved for data packets with a
priority value of 7. Packets that have not been given any priority value are placed in Queue 0 and thus given the
lowest priority for delivery.
Strict mode and weighted round robin system are employed on the Switch to determine the rate at which the queues
are emptied of packets. The ratio used for clearing the queues is 4:1. This means that the highest priority queue,
Queue 7, will clear 4 packets for every 1 packet cleared from Queue 0.
Remember, the priority queue settings on the Switch are for all ports, and all devices connected to the Switch will be
affected. This priority queuing system will be especially beneficial if your network employs switches with the capability
of assigning priority tags.
VLAN Description
A Virtual Local Area Network (VLAN) is a network topology configured according to a logical scheme rather than the
physical layout. VLANs can be used to combine any collection of LAN segments into an autonomous user group that
appears as a single LAN. VLANs also logically segment the network into different broadcast domains so that packets
are forwarded only between ports within the VLAN. Typically, a VLAN corresponds to a particular subnet, although not
necessarily.
VLANs can enhance performance by conserving bandwidth, and improve security by limiting traffic to specific
domains.
A VLAN is a collection of end nodes grouped by logic instead of physical location. End nodes that frequently
communicate with each other are assigned to the same VLAN, regardless of where they are physically on the
network. Logically, a VLAN can be equated to a broadcast domain, because broadcast packets are forwarded to only
members of the VLAN on which the broadcast was initiated.
Notes About VLANs
No matter what basis is used to uniquely identify end nodes and assign these nodes VLAN membership, packets
cannot cross VLANs without a network device performing a routing function between the VLANs.
The Switch supports IEEE 802.1Q VLANs and Port-Based VLANs. The port untagging function can be used to
remove the 802.1Q tag from packet headers to maintain compatibility with devices that are tag-unaware.
The Switch's default is to assign all ports to a single 802.1Q VLAN named "default."
The "default" VLAN has a VID = 1.
The member ports of Port-based VLANs may overlap, if desired.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
70
IEEE 802.1Q VLANs
Some relevant terms:
Tagging - The act of putting 802.1Q VLAN information into the header of a packet.
Untagging - The act of stripping 802.1Q VLAN information out of the packet header.
Ingress p ort - A port on a switch where packets are flowing into the Switch and VLAN decisions must be
made.
Egress port - A port on a switch where packets are flowing out of the Switch, either to another switch or to an
end station, and tagging decisions must be made.
IEEE 802.1Q (tagged) VLANs are implemented on the Switch. 802.1Q VLANs require tagging, which enables them to
span the entire network (assuming all switches on the network are IEEE 802.1Q-compliant).
VLANs allow a network to be segmented in order to reduce the size of broadcast domains. All packets entering a
VLAN will only be forwarded to the stations (over IEEE 802.1Q enabled switches) that are members of that VLAN, and
this includes broadcast, multicast and unicast packets from unknown sources.
VLANs can also provide a level of security to your network. IEEE 802.1Q VLANs will only deliver packets between
stations that are members of the VLAN.
Any port can be configured as either tagging or untagging. The untagging feature of IEEE 802.1Q VLANs allows
VLANs to work with legacy switches that don't recognize VLAN tags in packet headers. The tagging feature allows
VLANs to span multiple 802.1Q-compliant switches through a single physical connection and allows Spanning Tree to
be enabled on all ports and work normally.
The IEEE 802.1Q standard restricts the forwarding of untagged packets to the VLAN of which the receiving port is a
member.
Figure 3 - 2 IEEE 802.1Q Packet Forwarding
802.1Q VLAN Tags
The figure below shows the 802.1Q VLAN tag. There are four additional octets inserted after the source MAC
address. Their presence is indicated by a value of 0x8100 in the EtherType field. When a packet's EtherType field is
equal to 0x8100, the packet carries the IEEE 802.1Q/802.1p tag. The tag is contained in the following two octets and
consists of 3 bits of user priority, 1 bit of Canonical Format Identifier (CFI - used for encapsulating Token Ring packets
so they can be carried across Ethernet backbones), and 12 bits of VLAN ID (VID). The 3 bits of user priority are used
by 802.1p. The VID is the VLAN identifier and is used by the 802.1Q standard. Because the VID is 12 bits long, 4094
unique VLANs can be identified.
The tag is inserted into the packet header making the entire packet longer by 4 octets. All of the information originally
contained in the packet is retained.
The main characteristics of IEEE 802.1Q are as follows:
Assigns packets to VLANs by filtering.
Assumes the presence of a single global spanning
tree.
Uses an explicit tagging scheme with one-level
tagging.
802.1Q VLAN Packet Forwarding
Packet forwarding decisions are made based upon
the following three types of rules:
Ingress rules - rules relevant to the classification of
received frames belonging to a VLAN.
Forwarding rules between ports - decides whether
to filter or forward the packet.
Egress rules - determines if the packet must be
sent tagged or untagged.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
71
Figure 3 - 3 IEEE 802.1Q Tag
The EtherType and VLAN ID are inserted after the MAC source address, but before the original EtherType/Length or
Logical Link Control. Because the packet is now a bit longer than it was originally, the Cyclic Redundancy Check
(CRC) must be recalculated.
Figure 3 - 4 Adding an IEEE 802.1Q Tag
Port VLAN ID
Packets that are tagged (are carrying the 802.1Q VID information) can be transmitted from one 802.1Q compliant
network device to another with the VLAN information intact. This allows 802.1Q VLANs to span network devices (and
indeed, the entire network, if all network devices are 802.1Q compliant).
Unfortunately, not all network devices are 802.1Q compliant. These devices are referred to as tag-unaware. 802.1Q
devices are referred to as tag-aware.
Prior to the adoption of 802.1Q VLANs, port-based and MAC-based VLANs were in common use. These VLANs relied
upon a Port VLAN ID (PVID) to forward packets. A packet received on a given port would be assigned that port's PVID
and then be forwarded to the port that corresponded to the packet's destination address (found in the Switch's
forwarding table). If the PVID of the port that received the packet is different from the PVID of the port that is to
transmit the packet, the Switch will drop the packet.
Within the Switch, different PVIDs mean different VLANs (remember that two VLANs cannot communicate without an
external router). So, VLAN identification based upon the PVIDs cannot create VLANs that extend outside a given
switch (or switch stack).
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
72
Every physical port on a switch has a PVID. 802.1Q ports are also assigned a PVID, for use within the Switch. If no
VLANs are defined on the Switch, all ports are then assigned to a default VLAN with a PVID equal to 1. Untagged
packets are assigned the PVID of the port on which they were received. Forwarding decisions are based upon this
PVID, in so far as VLANs are concerned. Tagged packets are forwarded according to the VID contained within the
tag. Tagged packets are also assigned a PVID, but the PVID is not used to make packet-forwarding decisions, the
VID is.
Tag-aware switches must keep a table to relate PVIDs within the Switch to VIDs on the network. The Switch will
compare the VID of a packet to be transmitted to the VID of the port that is to transmit the packet. If the two VIDs are
different, the Switch will drop the packet. Because of the existence of the PVID for untagged packets and the VID for
tagged packets, tag-aware and tag-unaware network devices can coexist on the same network.
A switch port can have only one PVID, but can have as many VIDs as the Switch has memory in its VLAN table to
store them.
Because some devices on a network may be tag-unaware, a decision must be made at each port on a tag-aware
device before packets are transmitted - should the packet to be transmitted have a tag or not? If the transmitting port
is connected to a tag-unaware device, the packet should be untagged. If the transmitting port is connected to a tag-
aware device, the packet should be tagged.
Tagging and Untagging
Every port on an 802.1Q compliant switch can be configured as tagging or untagging.
Ports with tagging enabled will put the VID number, priority and other VLAN information into the header of all packets
that flow into and out of it. If a packet has previously been tagged, the port will not alter the packet, thus keeping the
VLAN information intact. Other 802.1Q compliant devices on the network to make packet-forwarding decisions can
then use the VLAN information in the tag.
Ports with untagging enabled will strip the 802.1Q tag from all packets that flow into and out of those ports. If the
packet doesn't have an 802.1Q VLAN tag, the port will not alter the packet. Thus, all packets received by and
forwarded by an untagging port will have no 802.1Q VLAN information. (Remember that the PVID is only used
internally within the Switch). Untagging is used to send packets from an 802.1Q-compliant network device to a non-
compliant network device.
Ingress Filtering
A port on a switch where packets are flowing into the Switch and VLAN decisions must be made is referred to as an
ingress port. If ingress filtering is enabled for a port, the Switch will examine the VLAN information in the packet
header (if present) and decide whether or not to forward the packet.
If the packet is tagged with VLAN information, the ingress port will first determine if the ingress port itself is a member
of the tagged VLAN. If it is not, the packet will be dropped. If the ingress port is a member of the 802.1Q VLAN, the
Switch then determines if the destination port is a member of the 802.1Q VLAN. If it is not, the packet is dropped. If
the destination port is a member of the 802.1Q VLAN, the packet is forwarded and the destination port transmits it to
its attached network segment.
If the packet is not tagged with VLAN information, the ingress port will tag the packet with its own PVID as a VID (if the
port is a tagging port). The switch then determines if the destination port is a member of the same VLAN (has the
same VID) as the ingress port. If it does not, the packet is dropped. If it has the same VID, the packet is forwarded and
the destination port transmits it on its attached network segment.
This process is referred to as ingress filtering and is used to conserve bandwidth within the Switch by dropping
packets that are not on the same VLAN as the ingress port at the point of reception. This eliminates the subsequent
processing of packets that will just be dropped by the destination port.
Default VLANs
The Switch initially configures one VLAN, VID = 1, called "default." The factory default setting assigns all ports on the
Switch to the "default." As new VLANs are configured in Port-based mode, their respective member ports are removed
from the "default."
Packets cannot cross VLANs. If a member of one VLAN wants to connect to another VLAN, the link must be through
an external router.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
73
NOTE: If no VLANs are configured on the Switch, then all packets will be forwarded to any
destination port. Packets with unknown source addresses will be flooded to all ports.
Broadcast and multicast packets will also be flooded to all ports.
An example is presented below:
VLAN Name
VID
Switch Ports
System (default)
1
5, 6, 7, 8, 21, 22, 23, 24
Engineering
2
9, 10, 11, 12
Marketing
3
13, 14, 15, 16
Finance
4
17, 18, 19, 20
Sales
5
1, 2, 3, 4
Table 3 - 1 VLAN Example - Assigned Ports
Port-based VLANs
Port-based VLANs limit traffic that flows into and out of switch ports. Thus, all devices connected to a port are
members of the VLAN(s) the port belongs to, whether there is a single computer directly connected to a switch, or an
entire department.
On port-based VLANs, NICs do not need to be able to identify 802.1Q tags in packet headers. NICs send and receive
normal Ethernet packets. If the packet's destination lies on the same segment, communications take place using
normal Ethernet protocols. Even though this is always the case, when the destination for a packet lies on another
switch port, VLAN considerations come into play to decide if the packet gets dropped by the Switch or delivered.
VLAN Segmentation
Take for example a packet that is transmitted by a machine on Port 1 that is a member of VLAN 2. If the destination
lies on another port (found through a normal forwarding table lookup), the Switch then looks to see if the other port
(Port 10) is a member of VLAN 2 (and can therefore receive VLAN 2 packets). If Port 10 is not a member of VLAN 2,
then the packet will be dropped by the Switch and will not reach its destination. If Port 10 is a member of VLAN 2, the
packet will go through. This selective forwarding feature based on VLAN criteria is how VLANs segment networks.
The key point being that Port 1 will only transmit on VLAN 2.
Network resources can be shared across VLANs. This is achieved by setting up overlapping VLANs. That is ports can
belong to more than one VLAN group. For example, by setting VLAN 1 members to ports 1, 2, 3 and 4 and VLAN 2
members to ports 1, 5, 6 and 7, Port 1 will belong to two VLAN groups. Ports 8, 9 and 10 are not configured to any
VLAN group. This means ports 8, 9 and 10 are in the same VLAN group.
VLAN and Trunk Groups
The members of a trunk group have the same VLAN setting. Any VLAN setting on the members of a trunk group will
apply to the other member ports.
NOTE: In order to use VLAN segmentation in conjunction with port trunk groups, you can first
set the port trunk group(s), and then you may configure VLAN settings. If you wish to change
the port trunk grouping with VLANs already in place, you will not need to reconfigure the VLAN
settings after changing the port trunk group settings. VLAN settings will automatically change in
conjunction with the change of the port trunk group settings.
Double VLANs
Double or Q-in-Q VLANs allow network providers to expand their VLAN configurations to place customer VLANs
within a larger inclusive VLAN, which adds a new layer to the VLAN configuration. This basically lets large ISP's
create L2 Virtual Private Networks and also create transparent LANs for their customers, which will connect two or
more customer LAN points without over-complicating configurations on the client's side. Moreover, the administrator
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
74
now has over 4000 VLANs that can be placed, and this greatly expands the VLAN network and enables greater
support of customers utilizing multiple VLANs on the network.
Double VLANs are basically VLAN tags placed within existing IEEE 802.1Q VLANs which we will call SPVIDs (Service
Provider VLAN IDs). These VLANs are marked by a TPID (Tagged Protocol ID), configured in hex form to be
encapsulated within the VLAN tag of the packet. This identifies the packet as double-tagged and segregates it from
other VLANs on the network, therefore creating a hierarchy of VLANs within a single packet.
Here is an example Double VLAN tagged packet.
Destination
Address
Source
Address
SPVLAN ( TPID +
Service P
rovider
VLAN Tag)
802.1Q C
EVLAN T
ag
(TPID + Customer VLAN
Tag)
Ether
Type
Payload
Consider the example below:
Figure 3 - 5 Double VLAN Example
In this example, the Service Provider Access Network switch (Provider edge switch) is the device creating and
configuring Double VLANs with different SPVIDs for specific customers (say Customer A and Customer B). Both
CEVLANs (Customer VLANs), CEVLAN 10 are tagged with the SPVID 100 (for Customer A) and SPVID 200 (for
Customer B) on the Service Provider Access Network, thus being a member of two VLANs on the Service Provider’s
network. In this way, the Customer can retain their normal VLAN ID’s and the Service Provider can seperate multiple
Customer VLANs using SPVLANs, thus greatly regulating traffic and routing on the Service Provider switch. This
information is then routed to the Service Provider’s main network and regarded there as one VLAN, with one set of
protocols and one routing behavior.
Regulations for Double VLANs
Some rules and regulations apply with the implementation of the Double VLAN procedure.
1. All ports must be configured for the SPVID and its corresponding TPID on the Service Provider’s edge switch.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
75
2. All ports must be configured as Access Ports or Uplink ports. Access ports can only be Ethernet ports while
Uplink ports must be Gigabit ports.
3. Provider Edge switches must allow frames of at least 1522 bytes or more, due to the addition of the SPVID
tag.
4. Access Ports must be an un-tagged port of the service provider VLANs. Uplink Ports must be a tagged port of
the service provider VLANs.
5. The switch cannot have both double and normal VLANs co-existing. Once the change of VLAN is made, all
Access Control lists are cleared and must be reconfigured.
6. Once Double VLANs are enabled, GVRP must be disabled.
7. All packets sent from the CPU to the Access ports must be untagged.
8. The following functions will not operate when the switch is in Double VLAN mode:
•
Guest VLANs
•
Web-based Access Control
•
IP Multicast Routing
•
GVRP
•
All Regular 802.1Q VLAN functions
802.1Q VLAN
The 802.1Q VLAN window lists all previously configured VLANs by VLAN ID and VLAN Name.
To view this window click L2 Features > 802.1Q VLAN
Figure 3 - 6 Current 802.1Q Static VLANs Entries window
To create a new 802.1Q VLAN entry or edit an existing one, click the Add/Edit VLAN tab at the top of the 802.1Q
VLAN window. A new window will appear, as shown below, to configure the port settings and to assign a unique name
and number to the new VLAN. See the table below for a description of the parameters in the new window.
NOTE: After all IP interfaces are set for your configurations, VLANs on the
switch can be routed without any additional steps.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
76
Figure 3 - 7 802.1Q VLAN window – Add/Edit VLAN Tab window
To return to the 802.1Q V LAN window, click the VLAN L ist Tab at the top of the window. To change an existing
802.1Q VLAN entry, click the corresponding Edit button. A new window will appear to configure the port settings and
to assign a unique name and number to the new VLAN. See the table below for a description of the parameters in the
new menu.
NOTE: The Switch supports up to 4k static VLAN entries.
Figure 3 - 8 802.1Q VLAN window – Edit window
The following fields can then be set in either the Add/Edit VLAN or Edit 802.1Q VLAN windows:
Parameter Description
VID (VLAN ID)
Allows the entry of a VLAN ID, or displays the VLAN ID of an existing VLAN in the Edit
window. VLANs can be identified by either the VID or the VLAN name.
VLAN Name
Allows the entry of a name for a new VLAN, or modifying the VLAN name in the Edit window.
VLAN Name should be no more than 32 characters in length.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
77
Advertisement
Enabling this function will allow the Switch to send out GVRP packets to outside sources,
notifying that they may join the existing VLAN.
Port Settings
Allows an individual port to be specified as member of a VLAN.
Tagged
Specifies the port as 802.1Q tagged. Checking the box will designate the port as Tagged.
Untagged
Specifies the port as 802.1Q untagged. Checking the box will designate the port as untagged.
Forbidden
Select this to specify the port as not being a member of the VLAN and that the port is
forbidden from becoming a member of the VLAN dynamically.
Not Member
Allows an individual port to be specified as a non-VLAN member.
Click Apply to implement changes made.
To search for a VLAN click the Find VLAN tab at the top of the screen which will display the following window, enter a
VLAN ID and click Find to display the settings for a previously configured VLAN.
Figure 3 - 9 802.1Q VLAN window – Find VLAN window
To create a VLAN Batch entry click the VLAN B atch S ettings tab at the top of the screen which will display the
following window.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
78
Figure 3 - 10 802.1Q VLAN window – VLAN Batch Settings window
The following fields can be set in the VLAN Batch Settings window:
Parameter Description
VID List (e.g 2-5)
Enter a VLAN ID List that can be added, deleted or configured.
Advertisement
Enabling this function will allow the Switch to send out GVRP packets to outside sources,
notifying that they may join the existing VLAN.
Port List (e.g. 1-5)
Allows an individual port list to be added or deleted as a member of the VLAN.
Tagged
Specifies the port as 802.1Q tagged. Checking the box will designate the port as Tagged.
Untagged
Specifies the port as 802.1Q untagged. Checking the box will designate the port as untagged.
Forbidden
Select this to specify the port as not being a member of the VLAN and that the port is
forbidden from becoming a member of the VLAN dynamically.
Click Apply to implement changes made.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
79
Voice VLAN
Voice VLAN is a VLAN used to carry voice traffic from IP phones. Because the sound quality of an IP phone call will
be deteriorated if the data is unevenly sent, the quality of service (QoS) for voice traffic shall be configured to ensure
the transmission priority of voice packet is higher than normal traffic.
The switches determine whether a received packet is a voice packet by checking its source MAC address. If the
source MAC addresses of packets comply with the organizationally unique identifier (OUI) addresses configured on
the Switch, the packets are determined as voice packets and transmitted in voice VLAN.
Figure 3 - 11 Application of Voice VLAN
The above figure is an example of voice VLAN. An IP phone and a PC connect to a HUB, and the HUB connects to a
switch that supports voice VLAN. The received untagged traffic by the switch can come from the IP phone or the PC.
The switch checks the SA of the received untagged packets. If the SA is the IP phone address, the packet will be
forwarded to voice VLAN. Otherwise, it will be forwarded to port-based VLAN, if no other VLAN types (e.g. subnet-
based VLAN or protocol VLAN) are applied.
NOTE: The Switch classifies voice VLAN packets based on OUI addresses
only for received untagged packets. For tagged packets, the Switch will
classify VLAN packets differently.
Voice VLAN Global Settings
This window allows you to configure the basic settings about voice VLAN
To view this window click L2 Features > Voice VLAN > Voice VLAN Global Settings.
Figure 3 - 12 Voice VLAN Global Settings window
The following fields can be configured.
Parameter Description
Voice VLAN State
Use the pull down menu to enable or disable the voice VLAN global settings.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
80
Voice VLAN Name
Click the radio button and enter a name for a voice VLAN.
Voice VLAN ID
(1-4094)
Click the radio button and enter a VLAN ID for a voice VLAN.
Priority
Use the pull down menu to set the priority of the voice VLAN. The voice VLAN priority will be
the priority associated with the voice VLAN traffic to distinguish the QoS of the voice traffic
from data traffic. It’s range is 0 – 7, the default value is 5.
Aging Time (1-
65535)
Enter a period of time in minutes to remove a port from voice VLAN if the port is an automatic
VLAN member. When the last voice device stops sending traffic and the MAC address of this
voice device is aged out, the voice VLAN aging timer will be started. The port will be removed
from the voice VLAN after expiration of voice VLAN aging timer.
Trap / Log
Use the pull down menu to enable or disable the trap/log state for voice VLAN. If there is a
new voice device detected or a port join/leave the voice VLAN dynamically, and the trap/log is
enabled, then a trap/log will be triggered.
Voice VLAN Port Settings
This window allows you to configure the voice VLAN port settings.
To view this window click L2 Features > Voice VLAN > Voice VLAN Port Settings.
Figure 3 - 13 Voice VLAN Port Settings window
The following fields can be configured.
Parameter Description
From Port / To Port
A consecutive group of ports that are part of the voice VLAN configuration starting with the
selected port.
State
Use the pull down menu to enable or disable the voice VLAN function on the port.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
81
Mode
Select the mode between Auto and Manual. If the mode is Auto, the port may become the
voice VLAN member port by auto-learning. If the MAC address of the the received packet
matches the configured OUI (Organizationally Unique Identifier) addresses, the port will be
learned as dynamic member port. The dynamic membership will be removed via the aging out
mechanism. If the mode is Manual, the port needs to be manually added into or removed from
the voice VLAN by 802.1Q VLAN configuration command.
Voice VLAN OUI Settings
This window allows the user to configiure the user-defined voice traffic’s OUI. There are some pre-defined OUIs and
when the user configures personal OUI, these pre-defined OUIs must be avoided. Followins are the pre-defined voice
traffic’s OUI:
OUI
Vendor
Mnemonic Name
00:E0:BB
3COM
3com
00:03:6B
Cisco
cisco
00:E0:75
Veritel
veritel
00:D0:1E
Pingtel
pingtel
00:01:E3
Siemens
siemens
00:60:B9
NEC/ Philips
nec&philips
00:0F:E2
Huawei-3COM
huawei&3com
00:09:6E
Avaya
avaya
To view this window click L2 Features > Voice VLAN > Voice VLAN OUI Settings.
Figure 3 - 14 Voice VLAN OUI Settings window
The following fields can be configured.
Parameter Description
OUI Address
Enter a user-defined OUI MAC address
Mask
Enter the user-defined OUI MAC address mask.
Description
Enter the description for the user-defined OUI.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
82
Subnet-based VLAN
The Switches uses IP subnet-based VLAN claasification to group devices.
Figure 3 - 15 Application of Subnet VLAN
The above figure is an example of subnet-based VLAN. The IP address of customer A is 172.18.0.1 and IP address of
customer B is 172.18.0.2. Both of them connect to the same port of the Switch through a HUB. Customers can access
Internet through VLAN 10 and the local server through VLAN 20. However, with the subnet VLAN configuration in the
example, IP 172.18.0.1 is assigned to VLAN 10 and 172.18.0.2 is assigned to VLAN 20. Customer A can only access
Internet, and customer B can only access the local server.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
83
Subnet-based VLAN Settings
The subnet-based VLAN settings are used to create, find or delete a subnet-based VLAN entry. A subnet-based
VLAN entry is an IP subnet-based VLAN classification rule. If an untagged or priority-tagged IP packet is received on
a port, its source IP address will be used to match the subnet-based VLAN entries. If the source IP is in the subnet of
an entry, the packet will be classified to the VLAN defined for this subnet.
To view this window, click L2 Features > Subnet VLAN > Subnet VLAN Settings as shown below:
Figure 3 - 16 Subnet VLAN Settings window
The following parameters can be configured:
Parameter Description
VLAN Name
The VLAN Name to be associated with the subnet.
VLAN ID
The VLAN ID to be associated with the subnet.
Priority
The priority to be associated with the subnet. Its range is 0-7.
IPv4 Network
Address
Is used to specify an IPv4 network address. The format is ipaddress/prefix length. The prefix
length of the IPv4 network address cannot be greater than 64.
Enter the appropriate information and click Add to create a new entry. To search for a particular entry enter the
appropriate information and click Find. To remove an entry click Delete. To view all entries on the Switch click Show
All. To remove all entries click Delete All.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
84
VLAN Precedence Settings
The VLAN precedence settings are used to configure VLAN classification precedence on each port. You can specify
the order of MAC-based VLAN classifications and subnet-based VLAN classifications. If a port’s VLAN classificataion
is a MAC-based precedence, MAC-based VLAN classification will be processed first. If MAC-based VLAN
classification fails, the subnet-based VLAN classification will be executed. If a port’s VLAN classification is subnet-
based VLAN precedence, the subnet-based VLAN classification will be processed first. If subnet-based VLAN
classification fails, the MAC-based VLAN classification will be executed.
To view this window, click L2 Features > Subnet VLAN > VLAN Precedence Settings as shown below:
Figure 3 - 17 VLAN Precedence Settings window
The following parameters can be configured:
Parameter Description
From Port…To Port
Specify the port or range of ports you wish to configure.
VLAN Precedence
Use the drop down menu to select the VLAN precedence, choose either MAC Based VLAN or
Subnet VLAN.
MAC Based VLAN – Specifies that the MAC-based VLAN classification is given precedence
over the subnet-based VLAN classification.
Subnet VLAN – Specifies that the subnet-based VLAN classification is given precedence over
the MAC-based VLAN classification.
Click Apply to implement changes made.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
85
Q-in-Q
Q-in-Q Settings
This function allows the user to enable or disable the Q-in-Q function. Q-in-Q is designed for service providers to carry
traffic from multiple users across a network.
Q-in-Q is used to maintain customer specific VLAN and Layer 2 protocol configurations even when the same VLAN ID
is being used by different customers. This is achieved by inserting SPVLAN tags into the customer’s frames when
they enter the service provider’s network, and then removing the tags when the frames leave the network.
Customers of a service provider may have different or specific requirements regarding their internal VLAN IDs and the
number of VLANs that can be supported. Therefore customers in the same service provider network may have VLAN
ranges that overlap, which might cause traffic to become mixed up. So assigning a unique range of VLAN IDs to each
customer might cause restrictions on some of their configurations requiring intense processing of VLAN mapping
tables which may exceed the VLAN mapping limit. Q-in-Q uses a single service provider VLAN (SPVLAN) for
customers who have multiple VLANs. Customer’s VLAN IDs are segregated within the service provider’s network
even when they use the same customer specific VLAN ID. Q-in-Q expands the VLAN space available while preserving
the customer’s original tagged packets and adding SPVLAN tags to each new frame.
To view this window click L2 Features > QinQ > QinQ Settings
Figure 3 - 18 QinQ Settings window
The following fields can be set:
Parameter Description
QinQ Global
Settings
Click the radio button to enable or disable the Q-in-Q Global Settings.
Inner TPID
This is used to decide if the ingress packet is c-tagged. Inner tag TPID is per system
configurable.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
86
From Port / To Port
A consecutive group of ports that are part of the VLAN configuration starting with the selected
port.
Role
The user can choose between UNI or NNI role.
UNI – To select a user-network interface which specifies that communication between the
specified user and a specified network will occur.
NNI – To select a network-to-network interface specifies that communication between two
specified networks will occur.
Missdrop
Use the drop down menu to enable or disable missdrop. If missdrop is enabled, the packet
that does not match any assignment rule in the Q-in-Q profile will be dropped. If disabled, then
the packet will be assigned to the PVID of the received port.
Outer TPID
The Outer TPID is used for learning and switching packets. The Outer TPID constructs and
inserts the outer tag into the packet based on the VLAN ID and Inner Priority.
Use Inner Priority
This is the priority given to the inner tag that is copied to the outer tag if this setting is enabled.
Add Inner Tag
(hex: 0x1-0xffff)
Deselect Disabled and enter an inner tag for the packet to use.
Click Apply to implement changes.
VLAN Translation Settings
VLAN translation translates the VLAN ID carried in the data packets it receives from private networks into those used
in the Service Providers network. To view this window click L2 Features > QinQ > VLAN Translation Settings
Figure 3 - 19 VLAN Translation Settings window
The following fields can be set:
Parameter Description
From Port / To Port
A consecutive group of ports that are part of the VLAN configuration starting with the selected
port.
CVID (1-4094)
The customer VLAN ID List to which the tagged packets will be added.
Action
Specify if you want SPVID packets to be added or replaced.
SPVID(1-4094)
This configures the VLAN to join the Service Providers VLAN as a tagged member.
Priority (0-7)
Select a priority for the VLAN ranging from 0-7. With 7 having the highest priority.
Click Apply to make a new entry and Delete All to remove a VLAN Translation entry.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
87
Q-in-Q and VLAN Translation Rules
For ingress untagged packets at UNI ports:
1. The Switch does not reference the VLAN translation table.
2. Check the switch VLAN tables. The sequence is MAC-based VLAN -> subnet-based VLAN -> protocol-based
VLAN -> port-based VLAN. If matched, the matched VLAN will become this packet’s ‘SPVLAN’.
For ingress tagged packets at UNI ports:
1. The Switch looks up the VLAN translation table. If matched, the VLAN tag will be translated (replace CEVLAN
with SPVLAN, or add SPVLAN).
2. Or, check the switch VLAN tables. The sequence is the same as above. The matched VLAN becomes this
packet’s ‘SPVLAN’.
802.1v Protocol VLAN
802.1v Protocol Group Settings
The table allows the user to create Protocol VLAN groups and add protocols to that group. The 802.1v Protocol VLAN
Group Settings supports multiple VLANs for each protocol and allows the user to configure the untagged ports of
different protocols on the same physical port. For example it allows the user to configure an 802.1Q and 802.1v
untagged port on the same physical port. The lower half of the table displays any previously created groups.
To view this window click L2 Features > 802.1v Protocol VLAN > 802.1v Protocol Group Settings
Figure 3 - 20 802.1v Protocol Group Settings window
The following fields can be set:
Parameter Description
Group ID
Select an ID number for the group, between 1 and 16.
Group Name
This is used to identify the new Protocol VLAN group. Type an alphanumeric string of up to 32
characters.
Protocol
This function maps packets to protocol-defined VLANs by examining the type octet within the
packet header to discover the type of protocol associated with it. Use the drop-down menu to
toggle between Ethernet_II, IEEE802.3_LLC and IEEE802.3_SNAP.
Protocol Value
(0-FFFF)
Enter a value for the Group.
Click Add to make a new entry and Delete All to remove an entry.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
88
802.1v Protocol VLAN Settings
The table allows the user to configure Protocol VLAN settings. The lower half of the table displays any previously
created settings.
To view this window click L2 Features > 802.1v Protocol VLAN > 802.1v Protocol VLAN Settings
Figure 3 - 21 Protocol VLAN Settings window
The following fields can be set:
Parameter Description
Group ID
Click the corresponding radio button to select a previously configured Group ID from the drop-
down menu.
Group Name
Click the corresponding radio button to select a previously configured Group Name from the
drop-down menu.
VID (1-4094)
Click the radio button to enter the VID. This is the VLAN ID that, along with the VLAN Name,
identifies the VLAN the user wishes to create.
VLAN Name
Click the radio button to enter a VLAN Name. This is the VLAN Name that, along with the
VLAN ID, identifies the VLAN the user wishes to create.
802.1p Priority
This parameter is specified if you want to re-write the 802.1p default priority previously set in
the Switch, which is used to determine the CoS queue to which packets are forwarded to.
Once this field is specified, packets accepted by the Switch that match this priority are
forwarded to the CoS queue specified previously by the user.
Click the corresponding box if you want to set the 802.1p default priority of a packet to the
value entered in the Priority (0-7) field, which meets the criteria specified previously in this
command, before forwarding it on to the specified CoS queue. Otherwise, a packet will have
its incoming 802.1p user priority re-written to its original value before being forwarded by the
Switch.
For more information on priority queues, CoS queues and mapping for 802.1p, see the QoS
section of this manual.
Port List (e.g.: 1-6)
Select the specified ports you wish to configure by entering the port number in this field, or
check the Select All Ports box.
Search Port List
This function allows the user to search all previously configured port list settings and display
them on the lower half of the table. To search for a port list, enter the port number you wish to
view and click Find. To display all previously configured port lists on the bottom half of the
screen click the Show All button. To clear all previously configured lists click the Delete All
button.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
89
RSPAN Settings
This table controls the RSPAN function. The purpose of the RSPAN function is to mirror the packets to a remote
switch. The packet travels from the switch where the monitored packet is received, through the intermediate switch,
then to the switch where the sniffer is attached. The first switch is also named the source switch. RSPAN VLAN
mirroring will only work when RSPAN Global Settings are enabled. RSPAN redirect function will work when RSPAN is
enabled and at least one RSPAN VLAN has been configured with redirect ports.
To view this window, click L2 Features > RSPAN Settings as shown below:
Figure 3 - 22 RSPAN Settings window
Enter the VLAN Name or VID and click Create. To remove an entry click Delete, to modify an entry click the
corresponding Edit button.
Figure 3 - 23 RSPAN Settings window – Edit
The following fields can be set:
Parameter Description
Source Po rts(e.g.:
1-4)
Select the specified ports you wish to configure by entering the port number in this field. Rx,
Tx, or Both can be selected from the dop down menu.
Redirect Port
Use the dop donw menu to specify the ouptut port for the RSPAN VLAN packets.
Tick to Add or Delete in the Source Ports or Redirect Ports and click Apply to add or remove the information. To
return to the RSPAN Settings window click <
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
90
GVRP Settings
The GARP VLAN Registration Protocol (GVRP) is a mechanism that dynamically maintain VLAN information on the
Switch, share the information to other GVRP-enabled switches and update switch information for other modules such
as interface.
The table allows the user to determine whether the Switch will share its VLAN configuration information with other
GVRP-enabled switches. In addition, Ingress Checking can be used to limit packet forwarding. When the received port
is not one of the packet’s VID specified VLAN, the packet will be dropped. Results can be seen in the table under the
configuration settings, as seen below.
To view this window click L2 Features > GVRP Settings
Figure 3 - 24 GVRP Settings window
The following fields can be set:
Parameter Description
GVRP Global
Settings
Click the radio buttons to enable or disable the GVRP global settings.
From Port/To Port
These two fields allow you to specify the range of ports that will be included in the Port-based
VLAN that you are creating using the 802.1Q Port Settings window.
PVID
The read-only field in the 802.1Q Port Table shows the current PVID assignment for each port,
which may be manually assigned to a VLAN when created in the 802.1Q Port Settings table.
The Switch's default is to assign all ports to the default VLAN with a VID of 1. The PVID is used
by the port to tag outgoing, untagged packets, and to make filtering decisions about incoming
packets. If the port is specified to accept only tagged frames - as tagging, and an untagged
packet is forwarded to the port for transmission, the port will add an 802.1Q tag using the PVID
to write the VID in the tag. When the packet arrives at its destination, the receiving device will
use the PVID to make VLAN forwarding decisions. If the port receives a packet, and Ingress
filtering is enabled, the port will compare the VID of the incoming packet to its PVID. If the two
are unequal, the port will drop the packet. If the two are equal, the port will receive the packet.
GVRP
The Group VLAN Registration Protocol (GVRP) enables the port to dynamically become a
member of a VLAN. GVRP is Disabled by default.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
91
Ingress Checking
This field can be toggled using the space bar between Enabled and Disabled. Enabled enables
the port to compare the VID tag of an incoming packet with the PVID number assigned to the
port. If the two are different, the port filters (drops) the packet. Disabled disables ingress
filtering. Ingress Checking is Disabled by default.
Acceptable Frame
Type
This field denotes the type of frame that will be accepted by the port. The user may choose
between Tagged Only, which means only VLAN tagged frames will be accepted, and
Admit_All, which mean both tagged and untagged frames will be accepted. Admit_All is
enabled by default.
Click Apply to implement changes made.
GVRP Timer Settings
The GVRP allows interoperability with other switches, so the values of the GVRP timers can be configured. This table
is used to set the GVRP Timer Settings.
To view this window click L2 Features > GVRP Timer Settings
Figure 3 - 25 GVRP Timer Settings window
The following fields can be set:
Parameter Description
Join Time
(100-100000)
The time in milliseconds that specifies the amount of time between the Switch receiving the
information about becoming a member of the group and actually joining the group. The default
is 200.
Leave Time
(100-100000)
The time in milliseconds that specifies the maximum amount of time between the Switch
receiving a leave group message from a host, and the Switch issuing a group membership
query. The default is 600. The Leave Time must be greater than 2 join times.
Leave All Time
(100-100000)
The time in milliseconds that specifies the amount of time the Switch will take to Leave All
groups. The default is 10000. The Leave All Time must be greater than the Leave Time.
Click Apply to implement changes made.
Asymmetric VLAN Settings
Shared VLAN Learning is a primary example of the requirement for Asymmetric VLANs. Under normal circumstances,
a pair of devices communicating in a VLAN environment will both send and receive using the same VLAN; however,
there are some circumstances in which it is convenient to make use of two distinct VLANs, one used for A to transmit
to B and the other used for B to transmit to A in these cases Asymmetric VLANs are needed. An example of when this
type of configuration might be required, would be if the client was on a distinct IP subnet, or if there was some
confidentiality-related need to segregate traffic between the clients.
To view this window click L2 Features > Asymmetric VLAN Settings
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
92
Figure 3 - 26 Asymmetric VLAN Settings window
Click Apply to implement changes.
MAC-based VLAN Settings
This table is used to create MAC-based VLAN entries on the switch. A MAC Address can be mapped to any existing
static VLAN and multiple MAC addresses can be mapped to the same VLAN. When a static MAC-based VLAN entry
is created for a user, the traffic from this user is able to be serviced under the specified VLAN regardless of the
authentiucation function operated on the port. Therefore each entry specifies a relationship of a source MAC address
with a VLAN.
To view this window click L2 Features > MAC-based VLAN Settings
Figure 3 - 27 MAC_based VLAN Settings window
The following fields can be set
Parameter Description
MAC Address
Specify the MAC address to be reauthenticated by entering it into the MAC Address field.
VID (1-4094) /
VLAN Name
Enter the VID or VLAN name of a previously configured VLAN.
Click Find, Add or Delete All for changes to take affect.
PVID Auto Assign Settings
This commands Enables or Disables PVID Auto Assign on the Switch. PVID is the VLAN that the switch will use for
forwarding and filtering purposes. If PVID Auto-Assign is Enabled, PVID will be possibly changed by previously set
PVID or VLAN configurations. When a user configures a port to VLAN X’s untagged membership, this port’s PVID will
be updated with VLAN X. In the form of a VLAN list command, PVID is updated with the last item on the VLAN list.
When a user removes a port from the untagged membership of the PVID’s VLAN, the port’s PVID will be assigned to a
default VLAN. When PVID Auto Assign is Disabled, PVID can only be changed by PVID configuration (user changes
explicitly). The VLAN configuration will not automatically change the PVID. The default setting is Enabled.
To view this window click L2 Features > PVID Auto Assign Settings
Figure 3 - 28 PVID Auto Assign Settings window
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
93
VLAN Trunk Settings
This window allows the user to configure the VLAN trunk on the port of the Switch. When the VLAN trunk function is
enabled, the VLAN trunk ports shall be able to forward all tagged frames with any VID.
To view this window click L2 Features > VLAN Trunk Settings
Figure 3 - 29 VLAN Trunk Settings window
The following fields can be set:
Parameter Description
VLAN Trunk
Global State
Click the radio buttons to enable or disable the VLAN Trunk global state settings.
VLAN Trunk
Settings
Tick to specify a port or range of ports to add to the VLAN trunk port members. When the port
belongs to the VLAN trunk port, all tagged frames shall be able to pass through the ports.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
94
Port Trunking
Understanding Port Trunk Groups
Port trunk groups are used to combine a number of ports together to make a single high-bandwidth data pipeline.
DES-3528/DES-3552 Series supports up to 8 port trunk groups with 2 to 8 ports in each group. A potential bit rate of
4400 Mbps can be achieved.
Figure 3 - 30 Example of Port Trunk Group
The Switch treats all ports in a trunk group as a single port. Data transmitted to a specific host (destination address)
will always be transmitted over the same port in a trunk group. This allows packets in a data stream to arrive in the
same order they were sent.
NOTE: If any ports within the trunk group become disconnected, packets intended for the
disconnected port will be load shared among the other unlinked ports of the link aggregation
group.
Link aggregation allows several ports to be grouped together and to act as a single link. This gives a bandwidth that is
a multiple of a single link's bandwidth.
Link aggregation is most commonly used to link a bandwidth intensive network device or devices, such as a server, to
the backbone of a network.
The Switch allows the creation of up to 8 link aggregation groups, each group consisting of 2 to 8 links (ports). The
aggregated links must be contiguous (they must have sequential port numbers) except the four (optional) Gigabit
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
95
ports, which can only belong to a single link aggregation group. All of the ports in the group must be members of the
same VLAN, and their STP status, static multicast, traffic control; traffic segmentation and 802.1p default priority
configurations must be identical. Port locking, port mirroring and 802.1X must not be enabled on the trunk group.
Further, the aggregated links must all be of the same speed and should be configured as full duplex.
The Master Port of the group is to be configured by the user, and all configuration options, including the VLAN
configuration that can be applied to the Master Port, are applied to the entire link aggregation group.
Load balancing is automatically applied to the ports in the aggregated group, and a link failure within the group causes
the network traffic to be directed to the remaining links in the group.
The Spanning Tree Protocol will treat a link aggregation group as a single link, on the switch level. On the port level,
the STP will use the port parameters of the Master Port in the calculation of port cost and in determining the state of
the link aggregation group. If two redundant link aggregation groups are configured on the Switch, STP will block one
entire group; in the same way STP will block a single port that has a redundant link.
To view the Trunking Settings window click L2 Features > Port Trunking
Figure 3 - 31 Port Trunking window
The following fields can be set
Parameter Description
Algorithm
The algorithm that the Switch uses to balance the load across the ports that make up the port
trunk group is defined by this definition. Choose MAC Source, MAC Destination, MAC Source
Dest, IP Source, IP Destination or IP Source Dest (See the Link Aggregation section of this
manual).
Group ID
Select an ID number for the group, between 1 and 8.
Type
This pull-down menu allows you to select between Static and LACP (Link Aggregation Control
Protocol). LACP allows for the automatic detection of links in a Port Trunking Group.
Master Port
Choose the Master Port for the trunk group using the pull-down menu.
State
Trunk groups can be toggled between Enabled and Disabled. This is used to turn a port trunking
group on or off. This is useful for diagnostics, to quickly isolate a bandwidth intensive network
device or to have an absolute backup aggregation group that is not under automatic control.
Active Port
Shows the port that is currently forwarding packets.
Member Ports
Choose the members of a trunked group. Up to eight ports per group can be assigned to a
group.
Flooding Port
A trunking group must designate one port to allow transmission of broadcasts and unknown
unicasts.
Click Apply to implement changes made.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
96
LACP Port Settings
The LACP Port Settings window is used to create port trunking groups on the Switch. Using the following window,
the user may set which ports will be active and passive in processing and sending LACP control frames.
To view the Trunking Settings window click L2 Features > LACP Port Settings
Figure 3 - 32 LACP Port Settings window
The following fields can be set
Parameter Description
From Port / To Port
A consecutive group of ports may be configured starting with the selected port.
Activity
Active - Active LACP ports are capable of processing and sending LACP control frames. This
allows LACP compliant devices to negotiate the aggregated link so the group may be
changed dynamically as needs require. In order to utilize the ability to change an aggregated
port group, that is, to add or subtract ports from the group, at least one of the participating
devices must designate LACP ports as active. Both devices must support LACP.
Passive - LACP ports that are designated as passive cannot initially send LACP control
frames. In order to allow the linked port group to negotiate adjustments and make changes
dynamically, one end of the connection must have "active" LACP ports (see above).
Click Apply to implement changes made.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
97
Traffic Segmentation
Traffic segmentation is used to limit traffic flow from a single port to a group of ports on either a single switch or a
group of ports on another switch in a switch stack. This method of segmenting the flow of traffic is similar to using
VLANs to limit traffic, but is more restrictive. It provides a method of directing traffic that does not increase the
overhead of the Master switch CPU. This page allows you to view which port on a given switch will be allowed to
forward packets to other ports on that switch. Select a port number from the drop down menu to display the forwarding
ports. To configure new forwarding ports for a particular port, select a port from the menu and click Apply.
To view the Traffic Segmentation window click L2 Features > Traffic Segmentation
Figure 7- 1. Traffic Segmentation window
The following fields can be set
Parameter Description
From Port / To Port
Check the corresponding boxes for the port(s) to transmit packets.
Forward Portlist
Check the boxes to select which of the ports on the Switch will be able to forward packets.
These ports will be allowed to receive packets from the port specified above.
Clicking the Apply button will enter the combination of transmitting port and allowed receiving ports into the Switch's
Current Traffic Segmentation Table.
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
98
IGMP Snooping
Internet Group Management Protocol (IGMP) snooping allows the Switch to recognize IGMP queries and reports sent
between network stations or devices and an IGMP host. When enabled for IGMP snooping, the Switch can add or
remove a port to a specific device based on IGMP messages passing through the Switch.
In order to use IGMP Snooping it must first be enabled for the entire Switch (see the DES-3528/DES-3552 S eries
Web Management Tool). You may then fine-tune the settings for each VLAN using the IGMP Snooping link in the L2
Features folder. When enabled for IGMP snooping, the Switch can open or close a port to a specific multicast group
member based on IGMP messages sent from the device to the IGMP host or vice versa. The Switch monitors IGMP
messages and discontinues forwarding multicast packets when there are no longer hosts requesting that they
continue.
IGMP Snooping Settings
Use the IGMP Snooping Settings window to enable or disable IGMP Snooping on the Switch. To modify the settings,
click the Edit button under Parameter Settings and a new table will appear for the user to configure.
To view this window, click L2 Features > IGMP Snooping > IGMP Snooping Settings as shown below:
Figure 3 - 33 IGMP Snooping Settings window
Clicking the Edit button will open the IGMP Snooping Parameters Settings window, shown below:
Figure 3 - 34 IGMP Snooping Parameters Settings - Edit window
xStack® DES-3528/DES-3552 Series Layer 2 Stackable Fast Ethernet Managed Switch User Manual
99
The following fields can be set.
Parameter Description
VLAN ID
This is the VLAN ID that, along with the VLAN Name, identifies the VLAN for which the user
wishes to modify the IGMP Snooping Settings.
VLAN Name
This is the VLAN Name that, along with the VLAN ID, identifies the VLAN for which the user
wishes to modify the IGMP Snooping Settings.
Rate Limit
Displays the rate limitation.
Querier IP
The querier IP address to send IGMP queries.
Querier Expiry
Time
Displays the querier expiry time.
Query Interval
(1-65535)
The Query Interval field is used to set the time (in seconds) between transmitting IGMP
queries. Entries between 1 and 65535 seconds are allowed. Default = 125.
Max Response
Time
(1-25)
This determines the maximum amount of time in seconds allowed before sending an IGMP
response report. The Max Response Time field allows an entry between 1 and 25 (seconds).
Default = 10.
Robustness Value
(1-255)
Adjust this variable according to expected packet loss. If packet loss on the VLAN is expected
to be high, the Robustness Variable should be increased to accommodate increased packet
loss. This entry field allows an entry of 1 to 255. Default = 2.
Last Member
Query Interval
(1-25 Sec)
This field specifies the maximum amount of time between group-specific query messages,
including those sent in response to leave group messages. Default = 1.
Data Driven Group
Expiry Time (1-
65535)
Allows the user to set the time that an IGMP Snooping data driven learning group will expire for
the specified VLAN. Default = 260.
Querier State
Choose Enabled to enable transmitting IGMP Query packets or Disabled to disable. The
default is Enabled.
Fast Leave
This parameter allows the user to enable the Fast Leave function. Enabled, this function will
allow members of a multicast group to leave the group immediately (without the
implementation of the Last Member Query Timer) when an IGMP Leave Report Packet is
received by the Switch. The default is Disabled.
State
Select Enabled to implement IGMP Snooping. This field is Disabled by default.
Report
Suppression
Select Enabled or Disabled for IGMP Snooping report suppression for specified VLANs.
Data Driven
Learning State
Allows users to enable or disable IGMP snooping data driven learning for the specified VLAN.
Data Driven
Learning Aged Out
Allows users to enable or disable aged out of IGMP Snooping data driven learning for the
specified VLAN.
Version
Allows the user to configure the IGMP version used on the Switch. The default value is 3.
Querier Role
This read-only field describes the behavior of the router for sending query packets. Querier will
denote that the router is sending out IGMP query packets. Non-Querier will denote that the
router is not sending out IGMP query packets. This field will only read Querier when the
Querier State and the State fields have been Enabled.
To modify the IGMP Snooping Router IP Settings click on the hyperlinked Browse Router IP which will show the
following window for the user to configure: