• Heating •

1 • • Daikin Altherma low temperature split • EHVH-C TABLE OF CONTENTS EHVH-C 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3 Electrical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 4 Combination table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Combination Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 5 Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Domestic Hot Water performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 6 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 7 Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Piping Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 8 Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Wiring Diagrams - Single Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 9 External connection diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 External Connection Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 10 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Installation Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 11 Hydraulic performance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Static Pressure Drop Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

• Daikin Altherma low temperature split • EHVH-C

1 1 • Heating • Daikin Altherma low temperature split 2 1 Features H e a t i n g E H V H - C D a i k i n A l t h • Integrated indoor unit: all-in-one floor standing unit including the domestic hot water tank • Energy efficient heating only system based on air to water heat pump technology • Perfect fit for new built as well as for low energy houses • Best seasonal efficiencies, providing the highest savings on running costs • Flexible configuration with respect to heat emitters

• Heating • Daikin Altherma low temperature split

3 • Daikin Altherma low temperature split • EHVH-C 2 Specifications 2-1 Technical Specifications EHVH04S18C3V EHVH08S18C3V EHVH08S26C9W EHVH16S18C3V EHVH16S26C9W Power input Nom. kW 0.075 0.190 Casing Colour White Material Precoated sheet metal Dimensions Unit Height mm 1,732 Width mm 600 Depth mm 728 Packed unit Height mm 1,922 Width mm 690 Depth mm 818 Weight Unit kg 115 116 126 120 129 Packed unit kg 128 129 139 133 142 Packing Material Wood / Carton / PE wrapping foil Weight kg 12 Tank Water volume l 180 260 180 260 Material Stainless steel (EN 1.4521) Maximum water temperature ºC 65 Maximum water pressure bar 10 Insulation Material EPS Heat loss kWh/ 24h 1.4 (1) 1.9 (1) 1.4 (1) 1.9 (1) Heat exchanger Quantity 1 - Material Stainless steel (EH 1 4521) Surface m² 1.9 Internal coil volume l 8.9 Pump Type DC motor Nr of speeds Inverter controlled Power input W 46 160 3-way valve Coefficient of flow (kV) Space heating m³/h 13 Domestic hot water tank m³/h 8 Expansion vessel Volume l 10 Max. water pressure bar 3 Pre pressure bar 1 Operation range Heating Ambien t Min. ºC -25 -25 (13) Max. ºC 25 35 (13) Water side Min. ºC 15 (5) Max. ºC 55 (5) Domestic hot water Ambien t Min. ºCDB -25 -20 Max. ºCDB 35 Water side Min. ºC 25 Max. ºC 60 Water side Heat exchanger Type Brazed plate Quantity 1 Water volume l 0.9 1.3 1.0 Water flow rate Min. l/min 5 11 Heating Max. l/min 25 34 50 Insulation material EPS Refrigerant circuit Gas side diameter mm 15.9 Liquid side diameter mm 6.35 9.52 Sound power level Nom. dBA 42 (2) 47 (2) Sound pressure level Nom. dBA 28 33 Water filter Diameter perforations mm 1 Material copper - brass - stainless steel

• Daikin Altherma low temperature split • EHVH-C

1 2 • Heating • Daikin Altherma low temperature split 4 2 Specifications Notes (1) Heatloss according to EN12897 (2) DB/WB 7ºC/6ºC - LWC 35ºC (DT=5ºC) (3) The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. (4) The sound pressure level mentioned is valid for pump medium speed - 0 ESP / medium speed - nominal flow / high speed - nominal flow (5) 15ºC-25ºC: BUH only, no heat pump operation = during commisioning (6) Including piping + PHE + back-up heater; excluding expansion vessel (7) Value mentioned is connection after ball valves, Connection at unit is G1-1/4 FEMALE (8) See separate drawing for operation range (9) For *RLQ* outdoor units \>55ºC BUH only, no heatpump operation (10) For *RHQ* outdoor units \>50ºC BUH only, no heatpump operation Water circuit Piping connections diameter inch G 1"1/4 (female) Safety valve bar 3 Manometer Yes Drain valve / fill valve Yes Shut off valve Yes Air purge valve Yes Total water volume l 4.4 (6) 4.8 (6) 5.8 (6) 4.5 (6) 5.5 (6) Safety devices Item 01 Thermal cutout (on indoor unit): 90-95ºC PED Category Art3§3 Category I Art3§3 Most critical part Name - Plate heat exchanger - Ps*V Bar*l - 51.0 (0.000) - Water circuit - Domestic hot water side Piping connections Cold water in / Hot water out inch G 1" FEMALE Recirculation connection inch G 1/2" FEMALE 2-2 Electrical Specifications EHVH04S18C3V EHVH08S18C3V EHVH08S26C9W EHVH16S18C3V EHVH16S26C9W Power supply Voltage range Min. % 10 Max. % 10 Wiring connections- Communication cable Quantity 3 Remark 2.5 mm² Wiring connections- Electric meter Quantity 2 Wiring connections- Preferential kWh rate power supply Quantity Power: 2 Wiring connections- Domestic hot water pump Quantity 2 Remark Minimum 0.75 mm² (2A inrush, 1A continuous) Wiring connections- For connection with R6T Quantity 2 Remark Minimum 0.75 mm² Wiring connections- For connection with A3P Remark Select diameter & type according to national & local regulations / Voltage: 230V / Max.current: 100mA / Min. 0.75mm² Wiring connections- For connection with M2S Quantity 3G Remark Select diameter & type according to national & local regulations / Voltage: 230V / Max.current: 100mA / Min. 0.75mm² Wiring connections- For connection with bottom plate heater Quantity 2 Remark Select diameter and type according to national and local regulations Wiring connections- For connection with user interface Quantity 2 Remark 0,75 mm² till 1,25 mm² (max length 500m) Wiring connections- For connection with optional FWXV* (demand input and output) Quantity 4 Remark 100 mA, minimum 0.75 mm² Notes For more details on current & voltage range, refer to the installation manual. 2-1 Technical Specifications EHVH04S18C3V EHVH08S18C3V EHVH08S26C9W EHVH16S18C3V EHVH16S26C9W

• Heating • Daikin Altherma low temperature split

5 • Daikin Altherma low temperature split • EHVH-C 2 Specifications (11) Minimum flow is mentioned for heat pump operation. To allow backup heater to operate safety a higher minimum flow is required. For *3V models 12 l/min (12) Minimum flow is mentioned for heat pump operation. To allow backup heater to operate safety a higher minimum flow is required. For *9W models 15 l/min (13) Refer to operation range for detail for differences between *RHQ* and *RLQ* models (14) PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (15) For more details on current & voltage range, refer to the installation manual.

• Daikin Altherma low temperature split • EHVH-C

1 3 • Heating • Daikin Altherma low temperature split 6 3 Electrical data 3 - 1 Electrical Data ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼

• Heating • Daikin Altherma low temperature split

7 • Daikin Altherma low temperature split • EHVH-C 4 Combination table 4 - 1 Combination Table ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼

• Daikin Altherma low temperature split • EHVH-C

1 5 • Heating • Daikin Altherma low temperature split 8 5 Capacity tables 5 - 1 Domestic Hot Water performance

• Heating • Daikin Altherma low temperature split

9 • Daikin Altherma low temperature split • EHVH-C 5 Capacity tables 5 - 1 Domestic Hot Water performance

• Daikin Altherma low temperature split • EHVH-C

1 5 • Heating • Daikin Altherma low temperature split 10 5 Capacity tables 5 - 1 Domestic Hot Water performance

• Heating • Daikin Altherma low temperature split

11 • Daikin Altherma low temperature split • EHVH-C 6 Dimensional drawings 6 - 1 Dimensional Drawings ″ ″ ″ ″ ″ ″ ″ ″ ″ ″

• Daikin Altherma low temperature split • EHVH-C

1 7 • Heating • Daikin Altherma low temperature split 12 7 Piping diagrams 7 - 1 Piping Diagrams

• Heating • Daikin Altherma low temperature split

13 • Daikin Altherma low temperature split • EHVH-C 8 Wiring diagrams 8 - 1 Wiring Diagrams - Single Phase ∼ ∼ ∼ ∼ ∼

• Daikin Altherma low temperature split • EHVH-C

1 8 • Heating • Daikin Altherma low temperature split 14 8 Wiring diagrams 8 - 1 Wiring Diagrams - Single Phase ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼

• Heating • Daikin Altherma low temperature split

15 • Daikin Altherma low temperature split • EHVH-C 8 Wiring diagrams 8 - 1 Wiring Diagrams - Single Phase

• Daikin Altherma low temperature split • EHVH-C

1 8 • Heating • Daikin Altherma low temperature split 16 8 Wiring diagrams 8 - 1 Wiring Diagrams - Single Phase ∼

• Heating • Daikin Altherma low temperature split

17 • Daikin Altherma low temperature split • EHVH-C 9 External connection diagrams 9 - 1 External Connection Diagrams

• Daikin Altherma low temperature split • EHVH-C

1 10 • Heating • Daikin Altherma low temperature split 18 10 Installation 10 - 1 Installation Method

• Heating • Daikin Altherma low temperature split

19 • Daikin Altherma low temperature split • EHVH-C 11 Hydraulic performance 11 - 1 Static Pressure Drop Unit

• Daikin Altherma low temperature split • EHVH-C

1 11 • Heating • Daikin Altherma low temperature split 20 11 Hydraulic performance 11 - 1 Static Pressure Drop Unit

These products are not within the scope of

the Eurovent certification program EEDEN13-725 • 04/13 • Copyright Daikin The present publication supersedes EEDEN12-725 The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, re- liability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or re- lated to the use and/or interpretation of this leaflet. All content is copy- righted by Daikin Europe N.V. BARCODE Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende