Daikin FAQ71BVV1B Techical Data
Text of the manual
• Split Sky Air • Indoor Units
1
• Indoor Units • R-410A • FAQ-BVV1B
TABLE OF CONTENTS
FAQ-BVV1B
1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
For indoor units only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3
Safety device settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5
Control systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6
Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . 8
Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
7
Piping diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
8
Wiring diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
External connection diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
9
Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Sound level data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
10
Air flow pattern. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
11
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Installation method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
• Indoor Units • R-410A • FAQ-BVV1B
1
• Split Sky Air • Indoor Units
2
1
Features
I
n
d
o
o
r
U
n
i
t
S
p
l
i
t
S
k
y
F
A
Q
-
B
V
V
1
B
R
-
4
1
0
A
•
Lightweight and compact
•
Ideal for shops, restaurants or offices requiring maximum floor space
for furniture, decorations and fittings
•
Fits neatly on a wall
•
Nice design and very compact casing
•
Both horizontal flaps and front panel can easily be removed and
washed
•
Auto-swing function ensures efficient air distribution via louvers that
close automatically when the unit is switched off
•
Extremely quiet in operation
•
Easy to install
•
Daikin remote controls give you easy control at your fingertips.
•
The wired remote control provides you with a schedule timer,
enabling to program the air conditioning daily or weekly.
•
The optional remote ON/OFF enables you to start/stop the air
conditioning from a mobile phone via a telephone remote control
(field supply).
•
The optional forced OFF enables you to switch off the unit
automatically. E.g. when a window is opened, the unit switches off.
•
The ’home leave’ operation button prevents large temperature
differences by continuously operating at a minimum (heating mode)
or maximum (cooling mode) preset level while you’re out or sleeping.
It also allows the indoor temperature to return quickly to your
favourite comfort level.
heat pump
optional
2 steps
optional
optional
• Split Sky Air • Indoor Units
3
• Indoor Units • R-410A • FAQ-BVV1B
2
Specifications
2-1
FOR INDOOR UNITS ONLY
FAQ71BVV1B
FAQ100BVV1B
Nominal Input
Cooling
kW
0.068
0.101
Heating
kW
0.068
0.101
2-2
TECHNICAL SPECIFICATIONS
FAQ71BVV1B
FAQ100BVV1B
Casing
Colour
White
Material
Resin
Dimensions
Packing
Height
mm
366
483
Width
mm
1147
1740
Depth
mm
337
299
Unit
Height
mm
290
360
Width
mm
1050
1570
Depth
mm
230
200
Weight
Unit
kg
13.0
26.0
Packed Unit
kg
17.0
34.0
Heat
Exchanger
Dimensions
Length
mm
863
1320
Nr of Rows
2
2
Fin Pitch
mm
1.40
1.40
Nr of Passes
4
9
Face Area m²
0.289
0.332
Nr of Stages
16
12
Empty Tubeplate
Hole
2
Tube type
Hi-XA
N-Hix
Fin
Type
Cross fin coil (Multi louver fins and HI-XA tubes)
Cross fin coil (Multi louver fins and N-hix tubes)
Fan
Type
Cross flow fan
Quantity
1
1
Air Flow Rate
Cooling
High
m³/min
19.0
23.0
Low
m³/min
15.0
19.0
Heating
High
m³/min
19.0
23.0
Low
m³/min
15.0
19.0
Fan
Motor
Quantity
1
1
Model
QCL9686M
QCL1163MA+QCL1163MB
Number of steps
2
2
Output
(high)
W
43
49
Cooling
Sound Power
High
dBA
59.0
61.0
Low
dBA
53.0
57.0
Sound
Pressure
High
dBA
43.0
45.0
Low
dBA
37.0
41.0
Heating
Sound Power
High
dBA
59.0
61.0
Low
dBA
53.0
57.0
Sound
Pressure
High
dBA
43.0
45.0
Low
dBA
37.0
41.0
Refrigerant
Type
R-410A
Piping
connections
Liquid (OD)
Type
Flare connection
Diameter
(OD)
mm
9.5
9.5
Gas
Type
Flare connection
Diameter
(OD)
mm
15.9
15.9
Drain
Diameter
(OD)
mm
VP13 (I.D. 13/O.D. 18)
VP20 (I.D. 20/O.D. 26)
Heat Insulation
Foamed polystyrene/polyethylene
Safety Devices
PC board fuse
• Indoor Units • R-410A • FAQ-BVV1B
2
• Split Sky Air • Indoor Units
4
2
Specifications
Standard
Accessories
Item
Installation and operation manual
Quantity
1
1
Item
Paper pattern for installation
Insulation tape
Installation panel
Screws
Insulation for fitting
Notes
The sound pressure level is measured via a microphone at 1m distance of the unit.
Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please
refer to sound level drawings of this chapter.
The sound power level is an absolute value indicating the power which a sound source generates.
2-3
ELECTRICAL SPECIFICATIONS
FAQ71BVV1B
FAQ100BVV1B
Power Supply
Phase
V1
V1
Frequency
Hz
50
50
Voltage
V
220-240
Power Supply Intake
Outdoor unit only
2-2
TECHNICAL SPECIFICATIONS
FAQ71BVV1B
FAQ100BVV1B
• Split Sky Air • Indoor Units
5
• Indoor Units • R-410A • FAQ-BVV1B
3
Safety device settings
FAQ71-100B
Model
Safety devices
FAQ71B
FAQ100B
FAQ∼B
Fuse
−
−
Fan motor thermal fuse (°C)
−
−
Fan motor thermal protector (°C)
−
OFF: 130±5
ON: 83±20
DU423-9101L
• Indoor Units • R-410A • FAQ-BVV1B
4
• Split Sky Air • Indoor Units
6
4
Options
Optional accessories
FAQ71B
FAQ100B
Remote control
Wired
BRC1D528
Infrared type
Heat pump
BRC7EA618
BRC7CA510W
Cooling only
BRC7EA619
BRC7CA511W
Wiring adapter for electrical appendices (2)*
*KRP4AA51
Installation box for adapter PCB
KRP4AA93
-
Central remote control
DCS302CA51
Electrical box with earth terminal (3 blocks)
KJB311AA
Unified ON/OFF control
DCS301BA51
Electrical box with earth terminal (2 blocks)
KJB212AA
Noise filter (for electromagnetic interface use only)
KEK26-1A
-
Schedule timer
DST301BA51
Interface adapter for Sky Air series
-
DTA112BA51
Remote sensor
KRCS01-1A
-
Drain up kit
K-KDU572CVE
-
Connector for forced on, forced off
-
EKROROA
3D044482A
Note:
1. Installation box (KRP4AA93) is necessary for each adapter marked*
• Split Sky Air • Indoor Units
7
• Indoor Units • R-410A • FAQ-BVV1B
5
Control systems
3TW23651-2
6.5 x 9 (Round end slit)
Cover open
Cover closed
5 x 7 (Round end slit)
HoleJ5
5 x 10 (Round end slit)
BRC1D527
• Indoor Units • R-410A • FAQ-BVV1B
6
• Split Sky Air • Indoor Units
8
6
Dimensional drawing & centre of gravity
6 - 1
Dimensional drawing
3D038540C
unit (mm)
50 or more
30 or more
(Required space)
J80 hole
approx. 345
approx. 475
FAQ71B
approx. 400
Mounting location
approx. 390
Piping direction
(Required space)
50 or more
Dimensions for
full open front
panel
Outside line
J80 hole
(piping and wiring
intake)
2500 or more
For installation in high
spaces
(Required space)
120 or less
1
Front panel
2
Front grille
3
Air outlet
4
Gas pipe (J15.9 Flare connection)
5
Liquid pipe (J9.5 Flare connection)
6
Drain hose VP13 (External dia J18)
7
Grounding terminal (M4)
8
Right side piping connection hole
9
Left side drain piping connection hole
Notes:
1
Location of general rated name plate
Right side plate outside surface
2
In case of using infrared remote control,
this position will be a signal receiver.
Refer to the drawing of infrared remote
control in detail.
Name plate
50 or more
Piping direction
Note) 2
Piping direction
(Required space)
3D044897A
unit (mm)
50 or more
250 or more
(Required space)
J80 hole
approx. 450
approx. 600
FAQ100B
8-5x20 Oval hole (for wood screw)
Mounting location
Detail j
A (Mounting hole for installation plate)
approx. 580
Piping direction
(Required space)
50 or more
50 or more
(Required space)
5-6x20 Oval hole (for wood screw)
13-J5 Hole (for wood screw)
2-J12 Hole (for bolt)
(piping and wiring
intake)
Note 2.
(service space for air filter)
Direction for air filter draw out
1
Front grille
2
Air filter
3
Discharge outlet
4
Gas piping connection (J15.9 flare)
5
Gas piping connection (J9.5 flare)
6
Drain pipe connection (VP20 O.D. J26)
7
Earth terminal(M4) (inside cover)
8
Slit hole for right side piping connection
9
Slit hole for left side piping connection
Notes:
1
Location of general rated name plate
Right side plate outside surface
2
In case of using infrared remote control, this
position will be a signal receiver. Refer to the
drawing of infrared remote control in detail.
Brand name plate
Ceiling surface
• Split Sky Air • Indoor Units
9
• Indoor Units • R-410A • FAQ-BVV1B
7
Piping diagram
4D037995B
O Check valve
L Flare connection
M Screw connection
N Flange connection
Z Pinched pipe
P Spinned pipe
Indoor heat exchanger
Field piping J9. 5C1220T-0
FAQ71-100B
Field piping J15.9C1220T-0
Refrigerant pipe connection port diameters
Model
A
B
FAQ71, 100B
J 9.5
J 15.9
To outdoor unit
Indoor unit
• Indoor Units • R-410A • FAQ-BVV1B
8
• Split Sky Air • Indoor Units
10
8
Wiring diagram
8 - 1
Wiring diagram
3D043881A
FAQ71B
A1P
Printed circuit board
HAP
Light emitting diode (service monitor green)
M1S
Motor (swing flap)
M1F
Motor (indoor fan)
R1T
Thermistor (air)
R2T
Thermistor (coil)
SS1
Selector switch (emergency)
X1M
Terminal block
X2M
Terminal block
Power supply
?
Signal receiver circuit
.
Signal transmission circuit
Infrared remote control
Receiver / display unit
A2P
Printed circuit board
A3P
Printed circuit board
BS1
Push button (on/off)
H1P
Light emitting diode (on-red)
H2P
Light emitting diode (timer-green)
H3P
Light emitting diode (filter sign-red)
H4P
Light emitting diode (defrost-orange)
SS1
Selector switch (main/sub)
SS2
Selector switch (wireless address set)
Connector for optional parts
X15A
Connector (float switch)
X35A
Connector (group control adapter)
Wired remote control
R1T
Thermistor (air)
SS1
Selector switch (main/sub)
To outdoor
unit
Note) 4
In case of simultaneous
operation system.
To outdoor unit
Notes
1. D : Terminal, F : Connector,
: Field wiring
2. In case using central remote control, connect it to the
unit in accordance with the attached instruction
manual.
3. Remote control model varies according to the
combination system, confirm technical materials and
catalogs, etc. before connecting.
4. X24A is connected when the infrared remote control
kit is being used.
5.
Shows short circuit connector
6. Symbols show as follows Red:red, Blk:black, Ylw:yellow,
Org:orange, Gry:gray, Prp:purple, Blu:blue
7. Confirm the method of setting the selector switch (SS1,
SS2) by installation manual and engeneering materials,
etc.
Receiver / display unit (attached to infrared remote control)
Note) 4
Indoor unit
(master)
Indoor unit
(slave)
Remote control
Norm.
Emerg.
Note) 2
Transmission wiring
central remote control
Wired remote control
Control box
SIDE
FRONT
ON/OFF input from outside
3D044228A
FAQ100B
A1P
Printed circuit board
A2P
Printed circuit board
(Transformer) 230V/16V)
C1R
Capacitor (M1F)
HAP
Light emitting diode (service monitor green)
KAR
Magnetic relay (M1S)
KPR
Magnetic relay (M1P)
M1F
Motor (indoor fan)
M1S
Motor (swing flap)
Q1M
Thermo switch (M1F embedded)
R1T
Thermistor (air)
R2T
Thermistor (coil)
S1Q
Limit switch (swing flap)
SS1
Selector switch (emergency)
V1TR
Phase control circuit
X1M
Terminal block
X2M
Terminal block
?
Signal receiver circuit
.
Signal transmission circuit
Wired remote control
R1T
Thermistor (air)
SS1
Selector switch (main/sub)
Infrared remote control
Receiver / display unit
A3P
Printed circuit board
A4P
Printed circuit board
BS1
Push button (on/off)
H1P
Light emitting diode (on-red)
H2P
Light emitting diode (timer-green)
H3P
Light emitting diode (filter sign-red)
H4P
Light emitting diode (defrost-orange)
SS1
Selector switch (main/sub)
SS2
Selector switch (wireless address set)
Connector for optional parts
X15A
Connector (float switch)
X25A
Connector (drain pump)
X35A
Connector (group control adapter)
X16A
X61A
Connector (interface adapter for sky air series)
To outdoor
unit
Note) 4
Wired remote
control
Control box
In case of simultaneous
operation system.
To outdoor unit
Notes
1. D : Terminal
F,
: Connector
2.
: Field wiring
3. In case using central remote control, connect it to
the unit in accordance with the attached
instruction manual.
4. X24A is connected when the infrared remote
control kit is being used.
5. Remote control model varies according to the
combination system, confirm technical materials
and catalogs, etc. before connecting.
6. Symbols show as follows Red:red, Blk:black,
Ylw:yellow, Org:orange, Gry:gray, Prp:purple,
Blu:blue
7. Confirm the method of setting the selector
switch (SS1, SS2) by installation manual and
engeneering materials, etc.
8. x15A, x25A are connected when the drain up kit
is being used. Connect it to the kit in accordance
with the attached installation manual.
Receiver / display unit
Note) 4
Indoor unit
(master)
Indoor unit
(slave)
Infrared remote
control
Emerg.
Norm.
Note) 8
• Split Sky Air • Indoor Units
11
• Indoor Units • R-410A • FAQ-BVV1B
8
Wiring diagram
8 - 2
External connection diagram
4D044475
V1, Model
Power supply
1∼50Hz
220V-240V
Main switch
Fuse
Fuse
NOTES
1
Line voltage wiring
Control circuit wiring
2
All wiring, components and materials to be produced on the site must comply with the applicable local and national codes.
3
Use copper conductors only.
4
See wiring diagrams for details.
5
Install fuse and mainswitch for safety.
6
All field wiring and components must be provided by a licensed electrician.
7
The unit shall be grounded in compilance with the applicable local and national codes.
8
Wiring shown are general points-of-connection guides only and are not intended for or to include all details for a specific
installation.
9
Never share a common power supply with other equipment.
V3, Model
Power supply
1∼50Hz
230V
Main switch
• Indoor Units • R-410A • FAQ-BVV1B
9
• Split Sky Air • Indoor Units
12
9
Sound data
9 - 1
Sound level data
Microphone
Model
Sound pressure level
Sound power level
230V
Measuring location
50Hz
Cooling
H/L
Heating
H/L
Cooling
H/L
Heating
H/L
FAQ71B
43/37
43/37
45/41
45/41
FAQ100B
59/53
59/53
61/57
61/57
• Split Sky Air • Indoor Units
13
• Indoor Units • R-410A • FAQ-BVV1B
9
Sound data
9 - 2
Sound pressure spectrum
4D038512C
Octave band sound pressure level
Octave band center frequency (Hz)
FAQ71B (Cooling/Heating)
approximate
threshold hearing
for continuous
noise
H (230V)
L (230V)
Note:
1. Sound pressure levels are measured in an anechoic room.
2. Data are valid at nominal operation conditions.
3. Operation sound level differs with operation and ambient conditions.
4D027787B
FAQ100B (Cooling)
Octave band sound pressure level
Octave band center frequency (Hz)
approximate
threshold hearing
for continuous
noise
H (230V)
L (230V)
Note:
1. Sound pressure levels are measured in an anechoic room.
2. Data are valid at nominal operation conditions.
3. Operation sound level differs with operation and ambient conditions.
4D027790B
FAQ100B (Heating)
Octave band sound pressure level
Octave band center frequency (Hz)
approximate
threshold hearing
for continuous
noise
H (230V)
L (230V)
Note:
1. Sound pressure levels are measured in an anechoic room.
2. Data are valid at nominal operation conditions.
3. Operation sound level differs with operation and ambient
conditions.
• Indoor Units • R-410A • FAQ-BVV1B
10
• Split Sky Air • Indoor Units
14
10
Air flow pattern
4D039573B
FAQ71B
Cooling - air velocity distribution
Air flow direction: 10° (downward)
FAQ71B
Cooling - air temperature distribution
Air flow direction: 10° (downward)
• Split Sky Air • Indoor Units
15
• Indoor Units • R-410A • FAQ-BVV1B
10
Air flow pattern
4D028547B
FAQ100B
Cooling - air velocity distribution
Air flow direction: 10° (downward)
FAQ100B
Cooling - air temperature distribution
Air flow direction: 10° (downward)
• Indoor Units • R-410A • FAQ-BVV1B
10
• Split Sky Air • Indoor Units
16
10
Air flow pattern
4D039574B
FAQ71B
Heating - air velocity distribution
Air flow direction: 65°C (downward)
FAQ71B
Heating - air temperature distribution
Air flow direction: 65°C (downward)
• Split Sky Air • Indoor Units
17
• Indoor Units • R-410A • FAQ-BVV1B
10
Air flow pattern
4D028548B
FAQ100B
Heating - air velocity distribution
Air flow direction: 65°C (downward)
FAQ100B
Heating - air temperature distribution
Air flow direction: 65°C (downward)
• Indoor Units • R-410A • FAQ-BVV1B
11
• Split Sky Air • Indoor Units
18
11
Installation
11 - 1 Installation method
Names and functions of parts
j
a Indoor unit
j
b Outdoor unit
j
c Infrared remote control
j
d Inlet air
j
e Discharged air
j
f
Air outlet
j
g Air flow flap (at air outlet)
j
h Refrigerant piping, connection electric wire
ji
Drain pipe
jj
Air inlet
The built-in air filter removes dust and dirt.
j
k Ground wire
Wire to ground from the outdoor unit to prevent electrical shocks.
ISO14001 assures an effective environmental
management system in order to help protect
human•health•and the environment from the potential
impact of our activities, products and services and to
assist in maintaining and improving the quality of
the•environment.
Daikin Europe N.V. is approved by LRQA for its Quality
Management System in accordance with the ISO9001
standard. ISO9001 pertains to quality assurance regarding
design, development, manufacturing as well as to services
related to the product.
Daikin units comply with the European
regulations that guarantee the safety of
the product.
Zandvoordestraat 300
B-8400 Ostend - Belgium
www.daikineurope.com
EEDE06-1/3 • 05/2006
Prepared in Belgium by Lannoo
The present publication is drawn up by way of
information only and does not constitute an offer
binding upon Daikin Europe N.V.. Daikin Europe N.V.
has compiled the content of this publication to the
best of its knowledge. No express or implied warranty
is given for the completeness, accuracy, reliability or
fitness for particular purpose of its content and the
products and services presented therein. Specifications
are subject to change without prior notice. Daikin
Europe N.V. explicitly rejects any liability for any direct
or indirect damage, In the broadest sense, arising from
or related to the use and/or interpretation of this
publication. All content is copyrighted by Daikin
Europe N.V..
ÉEEDE06-1/3ÇËÍ
Split - Sky Air
Daikin Europe N.V. is participating in the
EUROVENT Certification Programme.
Products are as listed in the EUROVENT
Directory of Certified Products.