Daikin FAQ71BVV1B Techical Data

Text of the manual

• Split Sky Air • Indoor Units

1 • Indoor Units • R-410A • FAQ-BVV1B TABLE OF CONTENTS FAQ-BVV1B 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 For indoor units only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3 Safety device settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 4 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 5 Control systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 6 Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . 8 Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 7 Piping diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 8 Wiring diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 External connection diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 9 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Sound level data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 10 Air flow pattern. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 11 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Installation method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

• Indoor Units • R-410A • FAQ-BVV1B

1 • Split Sky Air • Indoor Units 2 1 Features I n d o o r U n i t S p l i t S k y F A Q - B V V 1 B R - 4 1 0 A • Lightweight and compact • Ideal for shops, restaurants or offices requiring maximum floor space for furniture, decorations and fittings • Fits neatly on a wall • Nice design and very compact casing • Both horizontal flaps and front panel can easily be removed and washed • Auto-swing function ensures efficient air distribution via louvers that close automatically when the unit is switched off • Extremely quiet in operation • Easy to install • Daikin remote controls give you easy control at your fingertips. • The wired remote control provides you with a schedule timer, enabling to program the air conditioning daily or weekly. • The optional remote ON/OFF enables you to start/stop the air conditioning from a mobile phone via a telephone remote control (field supply). • The optional forced OFF enables you to switch off the unit automatically. E.g. when a window is opened, the unit switches off. • The ’home leave’ operation button prevents large temperature differences by continuously operating at a minimum (heating mode) or maximum (cooling mode) preset level while you’re out or sleeping. It also allows the indoor temperature to return quickly to your favourite comfort level. heat pump optional 2 steps optional optional

• Split Sky Air • Indoor Units

3 • Indoor Units • R-410A • FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101 Heating kW 0.068 0.101 2-2 TECHNICAL SPECIFICATIONS FAQ71BVV1B FAQ100BVV1B Casing Colour White Material Resin Dimensions Packing Height mm 366 483 Width mm 1147 1740 Depth mm 337 299 Unit Height mm 290 360 Width mm 1050 1570 Depth mm 230 200 Weight Unit kg 13.0 26.0 Packed Unit kg 17.0 34.0 Heat Exchanger Dimensions Length mm 863 1320 Nr of Rows 2 2 Fin Pitch mm 1.40 1.40 Nr of Passes 4 9 Face Area m² 0.289 0.332 Nr of Stages 16 12 Empty Tubeplate Hole 2 Tube type Hi-XA N-Hix Fin Type Cross fin coil (Multi louver fins and HI-XA tubes) Cross fin coil (Multi louver fins and N-hix tubes) Fan Type Cross flow fan Quantity 1 1 Air Flow Rate Cooling High m³/min 19.0 23.0 Low m³/min 15.0 19.0 Heating High m³/min 19.0 23.0 Low m³/min 15.0 19.0 Fan Motor Quantity 1 1 Model QCL9686M QCL1163MA+QCL1163MB Number of steps 2 2 Output (high) W 43 49 Cooling Sound Power High dBA 59.0 61.0 Low dBA 53.0 57.0 Sound Pressure High dBA 43.0 45.0 Low dBA 37.0 41.0 Heating Sound Power High dBA 59.0 61.0 Low dBA 53.0 57.0 Sound Pressure High dBA 43.0 45.0 Low dBA 37.0 41.0 Refrigerant Type R-410A Piping connections Liquid (OD) Type Flare connection Diameter (OD) mm 9.5 9.5 Gas Type Flare connection Diameter (OD) mm 15.9 15.9 Drain Diameter (OD) mm VP13 (I.D. 13/O.D. 18) VP20 (I.D. 20/O.D. 26) Heat Insulation Foamed polystyrene/polyethylene Safety Devices PC board fuse

• Indoor Units • R-410A • FAQ-BVV1B

2 • Split Sky Air • Indoor Units 4 2 Specifications Standard Accessories Item Installation and operation manual Quantity 1 1 Item Paper pattern for installation Insulation tape Installation panel Screws Insulation for fitting Notes The sound pressure level is measured via a microphone at 1m distance of the unit. Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to sound level drawings of this chapter. The sound power level is an absolute value indicating the power which a sound source generates. 2-3 ELECTRICAL SPECIFICATIONS FAQ71BVV1B FAQ100BVV1B Power Supply Phase V1 V1 Frequency Hz 50 50 Voltage V 220-240 Power Supply Intake Outdoor unit only 2-2 TECHNICAL SPECIFICATIONS FAQ71BVV1B FAQ100BVV1B

• Split Sky Air • Indoor Units

5 • Indoor Units • R-410A • FAQ-BVV1B 3 Safety device settings FAQ71-100B Model Safety devices FAQ71B FAQ100B FAQ∼B Fuse − − Fan motor thermal fuse (°C) − − Fan motor thermal protector (°C) − OFF: 130±5 ON: 83±20 DU423-9101L

• Indoor Units • R-410A • FAQ-BVV1B

4 • Split Sky Air • Indoor Units 6 4 Options Optional accessories FAQ71B FAQ100B Remote control Wired BRC1D528 Infrared type Heat pump BRC7EA618 BRC7CA510W Cooling only BRC7EA619 BRC7CA511W Wiring adapter for electrical appendices (2)* *KRP4AA51 Installation box for adapter PCB KRP4AA93 - Central remote control DCS302CA51 Electrical box with earth terminal (3 blocks) KJB311AA Unified ON/OFF control DCS301BA51 Electrical box with earth terminal (2 blocks) KJB212AA Noise filter (for electromagnetic interface use only) KEK26-1A - Schedule timer DST301BA51 Interface adapter for Sky Air series - DTA112BA51 Remote sensor KRCS01-1A - Drain up kit K-KDU572CVE - Connector for forced on, forced off - EKROROA 3D044482A Note: 1. Installation box (KRP4AA93) is necessary for each adapter marked*

• Split Sky Air • Indoor Units

7 • Indoor Units • R-410A • FAQ-BVV1B 5 Control systems 3TW23651-2 6.5 x 9 (Round end slit) Cover open Cover closed 5 x 7 (Round end slit) HoleJ5 5 x 10 (Round end slit) BRC1D527

• Indoor Units • R-410A • FAQ-BVV1B

6 • Split Sky Air • Indoor Units 8 6 Dimensional drawing & centre of gravity 6 - 1 Dimensional drawing 3D038540C unit (mm) 50 or more 30 or more (Required space) J80 hole approx. 345 approx. 475 FAQ71B approx. 400 Mounting location approx. 390 Piping direction (Required space) 50 or more Dimensions for full open front panel Outside line J80 hole (piping and wiring intake) 2500 or more For installation in high spaces (Required space) 120 or less 1 Front panel 2 Front grille 3 Air outlet 4 Gas pipe (J15.9 Flare connection) 5 Liquid pipe (J9.5 Flare connection) 6 Drain hose VP13 (External dia J18) 7 Grounding terminal (M4) 8 Right side piping connection hole 9 Left side drain piping connection hole Notes: 1 Location of general rated name plate Right side plate outside surface 2 In case of using infrared remote control, this position will be a signal receiver. Refer to the drawing of infrared remote control in detail. Name plate 50 or more Piping direction Note) 2 Piping direction (Required space) 3D044897A unit (mm) 50 or more 250 or more (Required space) J80 hole approx. 450 approx. 600 FAQ100B 8-5x20 Oval hole (for wood screw) Mounting location Detail j A (Mounting hole for installation plate) approx. 580 Piping direction (Required space) 50 or more 50 or more (Required space) 5-6x20 Oval hole (for wood screw) 13-J5 Hole (for wood screw) 2-J12 Hole (for bolt) (piping and wiring intake) Note 2. (service space for air filter) Direction for air filter draw out 1 Front grille 2 Air filter 3 Discharge outlet 4 Gas piping connection (J15.9 flare) 5 Gas piping connection (J9.5 flare) 6 Drain pipe connection (VP20 O.D. J26) 7 Earth terminal(M4) (inside cover) 8 Slit hole for right side piping connection 9 Slit hole for left side piping connection Notes: 1 Location of general rated name plate Right side plate outside surface 2 In case of using infrared remote control, this position will be a signal receiver. Refer to the drawing of infrared remote control in detail. Brand name plate Ceiling surface

• Split Sky Air • Indoor Units

9 • Indoor Units • R-410A • FAQ-BVV1B 7 Piping diagram 4D037995B O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipe Indoor heat exchanger Field piping J9. 5C1220T-0 FAQ71-100B Field piping J15.9C1220T-0 Refrigerant pipe connection port diameters Model A B FAQ71, 100B J 9.5 J 15.9 To outdoor unit Indoor unit

• Indoor Units • R-410A • FAQ-BVV1B

8 • Split Sky Air • Indoor Units 10 8 Wiring diagram 8 - 1 Wiring diagram 3D043881A FAQ71B A1P Printed circuit board HAP Light emitting diode (service monitor green) M1S Motor (swing flap) M1F Motor (indoor fan) R1T Thermistor (air) R2T Thermistor (coil) SS1 Selector switch (emergency) X1M Terminal block X2M Terminal block Power supply ? Signal receiver circuit . Signal transmission circuit Infrared remote control Receiver / display unit A2P Printed circuit board A3P Printed circuit board BS1 Push button (on/off) H1P Light emitting diode (on-red) H2P Light emitting diode (timer-green) H3P Light emitting diode (filter sign-red) H4P Light emitting diode (defrost-orange) SS1 Selector switch (main/sub) SS2 Selector switch (wireless address set) Connector for optional parts X15A Connector (float switch) X35A Connector (group control adapter) Wired remote control R1T Thermistor (air) SS1 Selector switch (main/sub) To outdoor unit Note) 4 In case of simultaneous operation system. To outdoor unit Notes 1. D : Terminal, F : Connector, : Field wiring 2. In case using central remote control, connect it to the unit in accordance with the attached instruction manual. 3. Remote control model varies according to the combination system, confirm technical materials and catalogs, etc. before connecting. 4. X24A is connected when the infrared remote control kit is being used. 5. Shows short circuit connector 6. Symbols show as follows Red:red, Blk:black, Ylw:yellow, Org:orange, Gry:gray, Prp:purple, Blu:blue 7. Confirm the method of setting the selector switch (SS1, SS2) by installation manual and engeneering materials, etc. Receiver / display unit (attached to infrared remote control) Note) 4 Indoor unit (master) Indoor unit (slave) Remote control Norm. Emerg. Note) 2 Transmission wiring central remote control Wired remote control Control box SIDE FRONT ON/OFF input from outside 3D044228A FAQ100B A1P Printed circuit board A2P Printed circuit board (Transformer) 230V/16V) C1R Capacitor (M1F) HAP Light emitting diode (service monitor green) KAR Magnetic relay (M1S) KPR Magnetic relay (M1P) M1F Motor (indoor fan) M1S Motor (swing flap) Q1M Thermo switch (M1F embedded) R1T Thermistor (air) R2T Thermistor (coil) S1Q Limit switch (swing flap) SS1 Selector switch (emergency) V1TR Phase control circuit X1M Terminal block X2M Terminal block ? Signal receiver circuit . Signal transmission circuit Wired remote control R1T Thermistor (air) SS1 Selector switch (main/sub) Infrared remote control Receiver / display unit A3P Printed circuit board A4P Printed circuit board BS1 Push button (on/off) H1P Light emitting diode (on-red) H2P Light emitting diode (timer-green) H3P Light emitting diode (filter sign-red) H4P Light emitting diode (defrost-orange) SS1 Selector switch (main/sub) SS2 Selector switch (wireless address set) Connector for optional parts X15A Connector (float switch) X25A Connector (drain pump) X35A Connector (group control adapter) X16A X61A Connector (interface adapter for sky air series) To outdoor unit Note) 4 Wired remote control Control box In case of simultaneous operation system. To outdoor unit Notes 1. D : Terminal F, : Connector 2. : Field wiring 3. In case using central remote control, connect it to the unit in accordance with the attached instruction manual. 4. X24A is connected when the infrared remote control kit is being used. 5. Remote control model varies according to the combination system, confirm technical materials and catalogs, etc. before connecting. 6. Symbols show as follows Red:red, Blk:black, Ylw:yellow, Org:orange, Gry:gray, Prp:purple, Blu:blue 7. Confirm the method of setting the selector switch (SS1, SS2) by installation manual and engeneering materials, etc. 8. x15A, x25A are connected when the drain up kit is being used. Connect it to the kit in accordance with the attached installation manual. Receiver / display unit Note) 4 Indoor unit (master) Indoor unit (slave) Infrared remote control Emerg. Norm. Note) 8

• Split Sky Air • Indoor Units

11 • Indoor Units • R-410A • FAQ-BVV1B 8 Wiring diagram 8 - 2 External connection diagram 4D044475 V1, Model Power supply 1∼50Hz 220V-240V Main switch Fuse Fuse NOTES 1 Line voltage wiring Control circuit wiring 2 All wiring, components and materials to be produced on the site must comply with the applicable local and national codes. 3 Use copper conductors only. 4 See wiring diagrams for details. 5 Install fuse and mainswitch for safety. 6 All field wiring and components must be provided by a licensed electrician. 7 The unit shall be grounded in compilance with the applicable local and national codes. 8 Wiring shown are general points-of-connection guides only and are not intended for or to include all details for a specific installation. 9 Never share a common power supply with other equipment. V3, Model Power supply 1∼50Hz 230V Main switch

• Indoor Units • R-410A • FAQ-BVV1B

9 • Split Sky Air • Indoor Units 12 9 Sound data 9 - 1 Sound level data Microphone Model Sound pressure level Sound power level 230V Measuring location 50Hz Cooling H/L Heating H/L Cooling H/L Heating H/L FAQ71B 43/37 43/37 45/41 45/41 FAQ100B 59/53 59/53 61/57 61/57

• Split Sky Air • Indoor Units

13 • Indoor Units • R-410A • FAQ-BVV1B 9 Sound data 9 - 2 Sound pressure spectrum 4D038512C Octave band sound pressure level Octave band center frequency (Hz) FAQ71B (Cooling/Heating) approximate threshold hearing for continuous noise H (230V) L (230V) Note: 1. Sound pressure levels are measured in an anechoic room. 2. Data are valid at nominal operation conditions. 3. Operation sound level differs with operation and ambient conditions. 4D027787B FAQ100B (Cooling) Octave band sound pressure level Octave band center frequency (Hz) approximate threshold hearing for continuous noise H (230V) L (230V) Note: 1. Sound pressure levels are measured in an anechoic room. 2. Data are valid at nominal operation conditions. 3. Operation sound level differs with operation and ambient conditions. 4D027790B FAQ100B (Heating) Octave band sound pressure level Octave band center frequency (Hz) approximate threshold hearing for continuous noise H (230V) L (230V) Note: 1. Sound pressure levels are measured in an anechoic room. 2. Data are valid at nominal operation conditions. 3. Operation sound level differs with operation and ambient conditions.

• Indoor Units • R-410A • FAQ-BVV1B

10 • Split Sky Air • Indoor Units 14 10 Air flow pattern 4D039573B FAQ71B Cooling - air velocity distribution Air flow direction: 10° (downward) FAQ71B Cooling - air temperature distribution Air flow direction: 10° (downward)

• Split Sky Air • Indoor Units

15 • Indoor Units • R-410A • FAQ-BVV1B 10 Air flow pattern 4D028547B FAQ100B Cooling - air velocity distribution Air flow direction: 10° (downward) FAQ100B Cooling - air temperature distribution Air flow direction: 10° (downward)

• Indoor Units • R-410A • FAQ-BVV1B

10 • Split Sky Air • Indoor Units 16 10 Air flow pattern 4D039574B FAQ71B Heating - air velocity distribution Air flow direction: 65°C (downward) FAQ71B Heating - air temperature distribution Air flow direction: 65°C (downward)

• Split Sky Air • Indoor Units

17 • Indoor Units • R-410A • FAQ-BVV1B 10 Air flow pattern 4D028548B FAQ100B Heating - air velocity distribution Air flow direction: 65°C (downward) FAQ100B Heating - air temperature distribution Air flow direction: 65°C (downward)

• Indoor Units • R-410A • FAQ-BVV1B

11 • Split Sky Air • Indoor Units 18 11 Installation 11 - 1 Installation method Names and functions of parts j a Indoor unit j b Outdoor unit j c Infrared remote control j d Inlet air j e Discharged air j f Air outlet j g Air flow flap (at air outlet) j h Refrigerant piping, connection electric wire ji Drain pipe jj Air inlet The built-in air filter removes dust and dirt. j k Ground wire Wire to ground from the outdoor unit to prevent electrical shocks.

ISO14001 assures an effective environmental

management system in order to help protect human•health•and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the•environment. Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Daikin units comply with the European regulations that guarantee the safety of the product. Zandvoordestraat 300 B-8400 Ostend - Belgium www.daikineurope.com EEDE06-1/3 • 05/2006 Prepared in Belgium by Lannoo The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, In the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.. ÉEEDE06-1/3ÇËÍ Split - Sky Air Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products.