BMS ETA-0832 Operational Manual
Read Online
Read the BMS ETA-0832 Operational Manual online using the built-in PDF viewer.
ETA-0832 Operational Manual: Key Pages of Document
BMS Bulut Makina Sanayi Ve Ticaret Ltd. Şti. İkitelli Organize Sanayi Bölgesi Dolapdere Sanayi Sitesi Ada 4 No : 7-9 İkitelli / İSTANBUL-TÜRKİYE Phone : +90 212 671 02 24 / 671 02 25 Fax : +90 212 671 02 26 web : www.bulutmak.com e-mail : [email protected] ...
4.Technology Parameter......................................................................................3 4.1 Standard Delivery.......................................................................................3 5.Measuring Procedure........................................................................ ...
BS. Suitable for the laboratory and for use in harsh field conditions. * The gauge can measure the thickness of non-magnetic coating layers on magnetic substrate.Such as: (aluminum, chrome, copper, enamel, rubber, paint) on magnetic substrate (steel, iron, alloy and magnetic stainless steel).. * The gauge can measure the thickness of non-metals coatings layers covered on non-magnetic metals substrate. Such as: (enamel, rubber, paint, vanish, plastic anodic-oxide layer) covered on non-nagnetic metals substrate (aluminum, brass, zinc and nonmagnetic s ...
ZEROING KEY MICRON-MICROINCH UNIT TRANSFORM KEY VALUE DECREASING KEY Operation ETA-0832 Manual Rev:00 4 / 6 ...
of last operation itself. The gauge will display "Fe / 0um"or"NFe / 0um" , if you want change the state of "Fe or NFe"press the"ZERO"key and the "POWER" key at the same time, and then release "POWER" key firstly, 2 seconds later release the "ZERO" key, the translation of "Fe or Nfe" finished. 5.2 Place the probe on the substrate or an uncoated standard steadily. Press the "ZERO" key and "CAL0 OK" will be on the Display before lifting the probe. If pressing the "ZERO" key but the probe is not placed on the substrate or an uncoated standard, the zero ad ...
accuracy of measurement, it is recommended that the calibrations should be done on the uncoated material to be measured. 8.2 Probe will eventually wear. Probe life will depend on the number of measurements taken and how abrasive the coating is. Replacement of a probe can be fitted by qualified persons only. 9.Restore Factory Setting 9.1 When to restore? It is recommended to restore factory setting in the one of following cases. A. The gauge does not measure any more. B. Because misoperation "+"key or "-"key causes the gauge not normally to measure. C. Measureme ...
Measuring Instruments PDF Instructions
Read carefully the instructions published in this manual before the first use of the level meter. Keep the manual at a safe place. The manufacturer reserves the right to implement changes without prior notice. průmyslová elektronika Capacitive level meters D
Service Instruction Sheet Introduction These instructions are intended for use with comparator rebuild kit (PN 3143). Rebuild kit 3143 con- tains all of the parts and tools required to rebuild the GaugeCalXP™ pressure comparator. Rebuilds should be performed
Internet Install Guide Postage Meter IS-280 iMeter™
1 0566EN October 2013 Metering systeMs Thermal energy meTer ge552 series Versions for wireless cenTralisaTion ISO 14001 0032A/2 OHSAS 18001 0064L/0 ISO 9001 0006/7 Losses of Pressure Installation The installation of the meter is carried out by replacing the pl