Austria Email FSN Operating And Installation Instructions
Read Online
Read the Austria Email FSN Operating And Installation Instructions online using the built-in PDF viewer.
Text of the manual
Operating and Installation Instructions
District heating tank
FSN and FSN-E
Please forward this on to the user!
Id.Nr.: 229224-9
2 • Id.Nr.: 229224-9
District heating tank FSN and FSN-E
Dear Customer!
You have taken the decision to purchase the hot water generation system with storage tank from our
company.
We would like to thank you for your confidence.
You will receive an elegant device built to state-of-the-art technical specifications, which complies
with all applicable regulations and has been ÖVE (Austrian Electro-technical Association)-tested. The
enamelling, which has been highly developed through continuous research, as well as ongoing quality
control during production, endows our hot water with tanks technical characteristics, which you will
always appreciate. The environmentally friendly CFC-free insulating foam ensures an extraordinarily low
standby energy consumption. For the sake of the environment, Austria Email AG's ARA (Junk Recy-
cling Austria AG) licence enables you to have the packaging of your device professionally disposed of.
The installation and initial commissioning may only be carried out by a licensed installation company in
accordance with these instructions.
Within this small brochure you will find all important information for the correct installation and opera-
tion. But still have your licensed installer explain the functionality of the device to you and demonstrate
its operation. Of course our company is also glad to be at your disposal through the Customer Services
and Sales Departments for any advice you may require.
Enjoy your district heating tank.
Id.Nr.: 229224-9 • 3
District heating tank FSN and FSN-E
1. Description
B
F
4
2. Hot Water Requirements
B
F
6
3. Save Energy
B
F
6
4. Standby Energy Consumption
B
F
6
5. Operating
B
F
7
6. Temperature Setting FSN-E
B
F
7
7. Summer- Winter Switch
B
F
8
8. Thermometer
B
F
8
9. Adjustment Range Limitation FSN-E
F
9
10. Operating Requirements
B
F
9
11. Installation and Safety Information
F
10
12. Dimensions Sketch
F
11
13. Special Suspensions
B
F
12
14. Connection Requirements
B
F
13
15. District Heating System Connection
B
F
14
16. Accessories and Plastic Base Installation
F
15
17. Domestic Hot Water Side Connection (pressure resistant)
B
F
16
18. Electrical Connection (FSN-E)
B
F
18
18.1 General Instructions
B
F
18
18.2 Connection Diagram FSN-E
B
F
18
19. Initial Commissioning
B
F
19
20. Decommissioning, Draining
B
F
19
21. Inspection, Servicing, Maintenance
B
F
20
22. Malfunctions
B
F
20
23. Guarantee and Warranty
B
F
21
Information for:
U = User
T = Technician
Table of Contents
Page
4 • Id.Nr.: 229224-9
District heating tank FSN and FSN-E
1. Description
B F
The district heating tanks are storage tanks that are heated via the district heating grid. The flow tem-
peratures required for this should be at least 60 °C. For district heating grids that do not operate all year
round there is the option of electric heating with the FSN-E type series.
The device is distinguished by the following characteristics:
• Double enamelled steel plate internal boiler with protective anode.
• High quality heat insulation made of polyurethane foam (CFC-free); boiler foam-fitted directly into the
outer casing. Benefit: low standby energy consumption.
• Stove enamelled, powder coated outer casing of steel plate, white.
• Precisely displaying capillary tube thermometer.
• Domestic water heated via a coil heat exchanger. Benefit: good heat layering within the boiler, good
thermal transfer.
• Zero-loss heat circuit regulation via an electrically actuated zone valve (1N ~ 230 V; 3 Watt)
with short heating up times (patent pending). This is why an electrical power supply at
1N ~ 230 V is necessary for the connection of a storage tank from the FSN or FSN-E type series.
• Elegant base to cover the connections, which is fitted with a service flap for better accessibility.
Id.Nr.: 229224-9 • 5
District heating tank FSN and FSN-E
The warming-up period and the maximum input power for district heating supplies can be taken from
the following diagrams:
Warming-up Period FSN and FSN-E*
Max. input power FSN and FSN-E*
*at a primary flow volume of 300l/h
Immediately after warming up, the heating circuit is closed so that no further losses are incurred as is
usually the case due to the formation of leakage currents when the system is only regulated through
back-flow temperature limitation.
Flow temperature in °C
Power in kW
Warming-up period in minutes
Flow temperature in °C
6 • Id.Nr.: 229224-9
District heating tank FSN and FSN-E
2. Hot Water
B F
Hot water consumption in the household is dependent upon the number of people, the sanitary fittings
in the flat or house, the insulation, the plumbing and the individual habits of the user.
The following table provides a few standard values for consumption.
The temperature of the cold water required for mixing for the stated hot water temperature was as-
sumed to be 12 °C.
3. Save Energy
B F
Our district heating storage tanks are real energy savers due to the high quality, ecologically friendly
polyurethane foam insulation and the built-in temperature regulation system.
Low storage water temperatures turn out to be particularly economical. That is why the level of the
continuously variable temperature adjustment should only be set in accordance with the actual hot
water requirements. That helps save energy and reduces lime-scale build up within the container.
4. Standby Energy Consumption
B F
If a water heater is heated up and no water is released for a long time after the heating process an,
albeit gradual but continuous, cooling of the stored water via the surface of the device will be the result.
Depending upon the construction type of the device, the size of the device, strength and quality of the
container insulation, the intensity and speed of this cooling off will vary.
This behaviour is measured at a stored water temperature of 65 °C over a period of 24 hours and
the amount of energy required to keep the water at a constant temperature throughout this period is
measured in kWh.
Standby energy consumption measured in accordance with EN 12897: max. 0,9 kW/24h
Hot water requirements
in litres
Required stored water
capacity in litres
at 37 °C
at 55 °C
at 80 °C
at 60 °C
Bath
150 - 180
55 - 66
78 - 94
Shower
30 - 50
11 - 18
16 - 26
Hand-wash
3 - 6
1 - 2
1.6 - 3.1
Hair-wash (short hair)
6 - 12
3 - 4.4
4.2 - 6.3
Hair-wash (long hair)
10 - 18
3.7 - 6.6
5.2 - 9.4
Bidet utilisation
12 - 15
4.4 - 5.5
6.3 - 7.8
Washing dishes
for 2 people per day
16
10
14
for 3 people per day
20
12.5
18
for 4 people per day
24
15.2
21.5
Housework per bucket
of cleaning water
10
6.3
9
Id.Nr.: 229224-9 • 7
District heating tank FSN and FSN-E
5. Operating
B F
All operating equipment required for the operation of the FSN and FSN-E district heating storage tanks
(temperature adjustment knob) and monitoring elements (operating light and thermometer) is gathered
together on an control panel at the front of the device.
In the case of the FSN, the temperature regulator and operating light are omitted.
This device is not designed to be operated by people (including children) with limited physical, sensory
or mental capacities or who lack the requisite experience and/or knowledge, unless they are super-
vised by a person responsible for their safety or have been instructed in the operation of the device
by the same. Children should be supervised in order to ensure that they do not play with the device.
6. Temperature Setting FSN-E
B F
As an aid to setting the temperature, the temperature regulator knob has 4 main positions, being:
Position: ➊ Frost protection for the storage tank (up to 30 °C)
➋ c. 40 °C, lukewarm storage water
➌ c. 65 °C, moderately hot storage water
To avoid accidental scaling with water that is too hot, this posi-
tion is recommended. The device works in a particularly eco-
nomical manner at this setting. The thermal losses are low and
the formation of boiler scale is largely avoided.
Low standby energy consumption
➍ c. 85 °C, hot storage water
Caution:
Turning the adjuster knob as far as possible to the left does not set the device heating at zero, nor
does it switch it off.
When operating with daytime electricity the temperature regulator should not be set any higher
than "Pos ➌" (c. 65 °C).
Due to the temperature regulator hysteresis (±7°K) and potential radiation losses (cooling of the plumb-
ing) the temperatures quoted are subject to a tolerance of ± 10°K.
FSN 110 E
8 • Id.Nr.: 229224-9
District heating tank FSN and FSN-E
7. Summer- Winter Switch
B F
Once the service flap has been opened the switch is freely accessible.
Here is where one can choose, whether the the storage tank should be powered by electricity (sum-
mertime operation) or by the district heating grid (wintertime operation).
8. Thermometer
B F
There is a remote thermometer built into the front panel of the device for monitoring the stored water
temperature.
The display value depends upon the temperature regulator setting. "Pos. ➍" and after completion of
the warm up process is the maximum display value reached (only in the case of electrical heating). For
other regulator positions the pointer deflection is reduced accordingly.
Remote thermometer
Id.Nr.: 229224-9 • 9
District heating tank FSN and FSN-E
9. Adjustment Range Limitation FSN-E F
To avoid accidental scalding by water that is too
hot, the adjustment range of the temperature
regulator can be limited to a max. of 65 °C. The
device must be electrically isolated from the
grid at all poles. Set to "Pos ➊". After open-
ing the connection space, remove the stop pin
in that is located in a drilling in the back of the
control panel and reinsert it into the hole with the
long shaft in front.
10. Operating Requirements
B F
The storage tanks must be used exclusively in accordance with the conditions set out on the rating
panel. The maximum input pressure should correspond to the nominal pressure stated on the rating
panel. In addition to the legally recognised national guidelines and standards, the connection condi-
tions of the local electricity and water works as well as those set out in the installation and operating
instructions must be complied with.
The room in which the device is operated must be frost-free. The installation of the device must be carried
out in a place where one might reasonably expect it to be, i.e. the device must be easily accessible in case
of servicing, repairs or in case it needs to be replaced. The hot water storage tank must only be connected
to rigid/fixed plumbing. In the case of hard water, we recommend the installation of a commercial de-calci-
fication device or alternatively we recommend the use of an lime-scale protection storage tank from Austria
Email AG and/or that you run the system at a maximum operating temperature of c.65 °C (set at "Pos ➌").
In order to prevent the ingress of foreign bodies, the entire device must be professionally flushed out in
accordance with ÖNORM H5195-1 prior to carrying out the initial installation of the district heating stor-
age tank.
In order to prevent the possibility of interference of the district heating storage tank. the electrical devices
used within the household must be ÖVE tested and must comply with EMV guideline 89/336/EWG.
To avoid damage, it is necessary to construct the connection of the storage tank with a detachable con-
nection (union).
Leaks from the storage tank as a result of an improper connection and damage and consequential dam-
age caused by this are excluded from the guarantee and product liability.
10 • Id.Nr.: 229224-9
District heating tank FSN and FSN-E
11. Installation and Safety Information
F
a) Important Installation Information! Do not bend the safety component sus-
pension hooks due to the possibility of breakage. A failure to take notice
of this warning could result in personal injury due to a falling device!
b) Every device is delivered with a wall rail for the insertion of the upper securing
hook, which is attached to the wall with two screws and supports the weight of
the device. Two additional screw fittings (as per the dimensions sketch with the
device dimensions) must be provided for affixing the lower tab of the device to
the wall; this only serves to secure the device against the wall and to prevent
lateral movement. Water heaters of a suspended construction type must not be
installed horizontally.
c) The securing hooks and therefore the suspension dimension A can be reposi-
tioned by moving the storage tank rear wall screws into other holes of the hook in 50 mm spac-
ings.
Caution: Only fixing hooks supplied by AE AG may be used!
d) During the installation due attention must be paid to device dimension sketches and any informa-
tion signs that may have been supplied together with the device.
e) Caution: The weight of the water heater including the weight of the water content (the nominal
capacity) must be taken into consideration for the selection of an installation point and/or the
preparation a device mounting surface sufficient to meet the technical loading and installation
strength requirements.
Special Suspension: see narrow wall and/or ceiling mounting.
f)
If a water heater is fitted with covers (cladding) in narrow small spaces or in suspended ceilings and the like,
it is crucial to ensure that the connection side of the device (water connections, electrical connection room
and/or boiler room) remains freely accessible and that heat accumulation is not generated. There
must be a free space of 500 mm for the dismantling of the heating flange. A space of at least 50
mm must be left above the device so that it can be hooked into the wall rails.
g) In terms of the choice and/or sequence of the installation material used on the system side (be
careful in the case of mixed installation) due consideration must be given to potential electro-
chemical processes (contact corrosion e.g. copper-steel) in accordance with good engineering
practice. We recommend the installation of insulating screw fixings.
h) If there is particularly aggressive water, which demands a special solution on the installation side,
the potential necessity for special constructed versions of the storage tank should be investigated
(please direct any related questions to our agents or directly to our company).
i)
The device is equipped with a safety temperature limiting device, which prevents any further heat-
ing of the devices beyond a water temperature of 110 °C.
(EN 60335 -2-21; ÖVE-EW41 , Part 2 (500) /1971). Therefore the choice of connection com-
ponents (connection pipes, circulation, safety valve combinations etc.) should be made in such
a way that the connection components could withstand temperatures of 110 °C in case of any
potential malfunction of the temperature regulator and that possible consequential damages
are avoided.
j)
The assembly and installation may only be carried out by authorised tradesmen.
k) There is a risk of scalding under certain operating conditions.
Id.Nr.: 229224-9 • 11
District heating tank FSN and FSN-E
12. Dimensions Sketch
F
Type
Con-
tents
Litre
Dimensions in mm
A
B
C
FSN 110
115
1366
1036
550-800
FSN 140
145
1566
1236
750-1000
FSN 190
195
1900
1570
950
12 • Id.Nr.: 229224-9
District heating tank FSN and FSN-E
13. Special Suspension
B F
Thin wall suspension
Ceiling suspension
Id.Nr.: 229224-9 • 13
District heating tank FSN and FSN-E
14. Connection Requirements
B F
1 Hot Water Storage Tank
2 Heat Exchanger
3 Back-flow Valve
4 Zone Valve
5 Safety Valve
6 Return Flow Inhibitor
7 Dirt Trap
8 Drainage Valve
9 Electric Heating
10 Bleeding
Thermostat for electric heating
Thermostat for district heating
District heating
back-flow
Hot water
Cold water
District heating flow
14 • Id.Nr.: 229224-9
District heating tank FSN and FSN-E
• Maximum operating pressure on the heater side:
6 bar
• Maximum flow temperature on the heater side:
95 °C
• Maximum operating pressure on the domestic water side:
6 bar
• Average domestic water temperature:
60 °C
• Maximum pressure differential in the heating circuit:
1.2 bar (5 bar on demand)
• Recommended throughput volume:
300 l/h
• Domestic water connections:
1/2“
• Heater connections:
1/2“
• Dimensions:
Nominal capacity:
110l
height:
1,338 mm
width:
520 mm
depth:
520 mm
variable wall connection
15. District Heating System Connection
F
The regulation of the heating-up temperature via the remote heating circuit is done electrically and the
setting is fixed in the factory. An additionally installed temperature limiting device prevents overly high
back-flow temperatures. Changes to the settings may only be carried out following consultation with
the manufacturer.
Due to the high permissible pressure differential in the primary heating circuit it is not necessary to
regulate this pressure for the district heat storage tanks, however it must not exceed 1.2 bar. In order
to avoid malfunctions and the ingress of foreign bodies a dirt trap should be installed in the direction of
flow in the district heating supply pipe.
In all cases the connection of the district heat stor-
age tank should
be before the first radiator.
RADIATOR
FSN 110
Stair well
Flat
Id.Nr.: 229224-9 • 15
District heating tank FSN and FSN-E
16. Accessories and Plastic Base Installation
F
16 • Id.Nr.: 229224-9
District heating tank FSN and FSN-E
17. Domestic Hot Water Side Connection (pressure resistant)
F
In cases in which unsuitable or non-functional storage tank connection fittings are used as well as
in cases in which the stated operating pressure is exceeded, we shall refuse to guarantee the water
heater in any way whatsoever.
All water heaters that display a nominal pressure of 6 bar (ATO or kp/cm2) on their rating plates
are pressure resistant storage tanks and can be connected pressure-tight at a mains pressure of
up to 5.5 bar (ATO). If the system pressure is higher then a pressure reduction valve must be
installed in the cold water input pipe.
The water connection must only take place via a certified membrane safety valve or a membrane safety
valve combination - connection fitting for pressure resistant storage tanks.
A safety valve combination consists of shut-off, back-flow, drainage and safety valves with expand-
able water outlet and is installed between the storage tank's cold water inlet pipe (blue) and cold
water inlet in an appropriate sequence.
As a general rule the following is to be noted:
In order to ensure the faultless functioning of the connection fittings these may only be installed in
frost-protected spaces. The outlet of the safety valve must be open and observable and/or the outlet
pipe from the drip tray (water overflow funnel) must not terminate outside so that neither frost nor
blockages due to dirt and the like can result in a malfunction. Care must be taken to ensure that the
drip container is not blocked.
Furthermore, care must be taken to ensure that the outlet pipe of the safety valve is installed with a
constant incline.
No shut-off valve or any other restriction may be installed between the safety valve and the storage
tank cold water inlet.
The safety valve must be configured for a trigger pressure that is lower than the nominal pressure (6
bar) of the storage tank. Before the final connection of the storage tank the cold water inflow pipe
must be flushed through.
Once the water has been connected and the storage tank has been filled without air bubbles, the
function of the connection fittings must be checked.
a) In order to avoid a blockage of the safety valve's venting mechanism as a result of lime-scale
depositing, the safety valve's venting mechanism should be operated from time to time dur-
ing the operation of the system. It should be observed whether or not the valve re-closes after
releasing the venting mechanism and whether or not the queued water is drained off completely
Drainage Valve
Safety Valve
Back-flow Valve (Return-flow Inhibitor)
Test Valve
poss. Pressure Reduction Valve
Shut-off Valve
User Fittings
Id.Nr.: 229224-9 • 17
District heating tank FSN and FSN-E
via the funnel or outlet pipe.
b) In the case where safety valves are installed before water heaters, a check should be made as to
whether the safety valve reacts when the water heater is heated up. This can be verified by way
of water egress out of the outlet pipe.
Implementation: Operator, Installation Company
Interval: every 6 months
Servicing and repair:
If no water escapes when the water heater is heated up or if the safety valve is permanently leaky,
then an attempt should be made to unblock the valve or remove any foreign bodies (e.g. lime-scale
particles) on the seal component by operating the venting mechanism several times.
If this fails then an overhaul by an installation company should be arranged. In case of damage to the
valve seat or seal then the safety valve will have to be completely replaced.
Implementation: Installation Company
Interval: annually
To check the back-flow valve the shut-off valve is closed and no water should escape via the open
test valve.
The operation of the storage tank takes place via the hot water valve of the control device (mixing
unit). Therefore the storage tank is permanently under pressure. In order to protect the inner boiler
from overpressure during heating-up. the excess water that arises is drained off via the safety valve.
To avoid overpressure damage to the water heater it is crucial to replace calcified safety valves. In
the event of a drop in pipeline pressure, the back-flow valve prevents the back-flow of the hot water
into the cold water pipe system thereby protecting the boiler from being heated up in the absence
of water. The storage tank can be separated from the cold water supply grid by the shut-off valve on
the water side and therefore also in terms of pressure and can be drained off via the drainage valve if
necessary.
18 • Id.Nr.: 229224-9
District heating tank FSN and FSN-E
18. Electrical Connection FSN-E
F
18.1 General Instructions
a) As a matter of principle, the electrical connectivity is to be carried out as per the circuit diagram
pasted in to the connection space of the storage tank.
b) Ensure the correct connection voltage!
c) An all-pole isolation switch with a contact opening width of 3 mm is to be provided in the electri-
cal supply line. Automatic circuit breakers are also permissible as isolators.
d) The connection cable must be inserted into the connection space of the storage tank and be
prevented from being pulled out and twisted by a strain relief mechanism. For register storage
heaters a second cable insert is provided for the charging pump control cable.
e) For the installation and intrusive interventions into the device the hot water storage tank must first
be isolated completely (all poles) and on every side from the power supply in compliance with EN
50110 (ÖVE, TAEV).
Before carrying out any further works the system must be secured against the accidental recon-
nection of the power supply (remove the fuses, trigger the mains circuit breaker).
18.2 Connection Diagram FSN-E
L,N .....Power supply grid Connection voltage ~230V
Id.Nr.: 229224-9 • 19
District heating tank FSN and FSN-E
19. Initial Commissioning
B F
Before switching on the electrical power the storage tank must be filled with water.
During the heating up process the expansion water generated in the inner boiler must drip out of the
safety valve in the case of a pressure resistant connection and out of the mixer unit in the case of a
non-pressure connection.
Caution: The initial heating up process must be carried out and monitored by a licensed pro-
fessional and The hot water drainage pipe as well as parts of the safety fittings can get hot.
After heating up the configured temperature and the actual temperature of the extracted water
should by about the same.
20. Decommissioning, Draining
B F
If a water heater is put out of action or not used for a lengthy period then it must be drained and
completely isolated (all-poles) from the power supply. Switch off the supply line switches or automatic
circuit breakers.
In rooms permanently subject to frost damage the water heater must be drained before the start of
the cold weather season if the device will be out of action for several days and is not being operating
in frost protection mode (see Point 6).
The draining of the domestic water is carried out once the shut-off valve has been closed in the cold
water feed via the drainage valve of the safety valve combination whilst all hot water valves of the
connected operating mechanisms are simultaneously open. It is also possible to drain the system via
the safety valve in the excess water funnel (drip tray). In order to do so the safety valve knob is turned
to the "Test" position.
Careful: hot water can escape when draining.
Furthermore when there is a risk of frost, attention must also be paid to the fact that not only the
water in the water heater and in the hot water plumbing can freeze but also in the all cold water pipe-
work to the operating mechanisms and to the device itself. It is therefore useful to drain off all water
carrying fittings and plumbing (including the heating circuit = smooth pipe heat exchanger) right back
to the frost protected part of the household water system (household water connection).
If the storage system is brought back into service then it is crucial to ensure that it is filled with water
and that bubble free water emerges at the hot water valves.
20 • Id.Nr.: 229224-9
District heating tank FSN and FSN-E
21. Inspection, Servicing, Maintenance
B F
a) During heating-up the excess water must be seen to drip out of the safety valve out-
let (in the case of non-pressure connections the excess water will drip out of
the mixer unit valve). When fully heated-up (c.85 °C) the excess water volume is
c. 3.5% of the storage tank volume.
The function of the safety valve should be checked regularly. When lifting or turning the safety
valve testing knob to the "Test" position the water must flow unhindered out of the body of the
safety valve and into the drainage funnel.
Caution: The cold water inlet plumbing and parts of the storage tank connection fittings can
become hot as a result.
If the water heater is not heated up or if no hot water is extracted then there should be no water
dripping
out of the safety valve. If this is the case then either the water feed pressure is too high (install
via 5.5 bar pressure reduction valve) or the safety valve is defective. Please called the installation
expert immediately!
b) In the case of extremely hard water then the removal of the boiler scale accumulating in the stor-
age tank's inner boiler as well as the freely deposited lime-scale must be removed by a profes-
sional after one or two years of operation.
The cleaning process is carried out by removing the flange opening of the heating flange and
cleaning the storage tank. When re-installing the heating flange it is crucial to use a new seal. The
specially enamelled inner container of the water heater must not come into contact with boiler
scale solvent - do not use the de-calcifying pump. Remove lime-scale with wood and either
remove it with a vacuum cleaner or wipe out with a cloth.
Afterwards the device must be thoroughly rinsed (in accordance with ÖNORM H5195-1) and the
heating up process is to be observed as per initial commissioning.
c) In order to make substantiated claims under the guarantee provided by AE AG the in-built pro-
tective anode requires an inspection by the expert at maximum intervals of 2 years of operation.
The protective current resister below the heating unit fixing screw must not be damaged or
removed during servicing.
d) Do not use any scouring agents to clean the device and do not use any paint thinners (such as
Nitro, trichloride etc.)
It is best to clean it using a damp cloth with a few drops of a liquid household cleaning agent.
22. Malfunctions
B F
If the storage tank water does not heat up please check whether the circuit breaker (automatic circuit
breaker) in the distribution cabinet or else the melting fuses have been tripped and check the setting
of the temperature regulator.
In any other case do not attempt to rectify the fault yourself. Either turn to a licensed installer or to
our Customer Service Department for assistance. Professionals often only need to make a few quick
adjustments to return the storage tank to full working order. Please provide the type designation and
serial number of your storage tank when reporting the issue, which you will find on the rating plate.
Id.Nr.: 229224-9 • 21
District heating tank FSN and FSN-E
Warranty, Guarantee and Product Liability
The warranty is granted in accordance with the statutory provisions of the Republic of Austria, as well as of the EU.
1. Prerequisite for the provision of warranty services by Austria Email AG (hereinafter referred to as AE AG) shall be the presen-
tation of the paid invoice for the purchase of the device for which the warranty service is claimed, whereby the identity of the
device with regard to the model and the manufacturing number must be evident from the invoice and must be documented by
the claimant. The General Terms and Conditions, Terms and Conditions of Sale and Delivery of AE AG shall apply exclusively.
2. To the extent required by the law, respectively in the Operator’s Manual and Installation Instructions, the assembly, erection,
connection and commissioning of the unit for which the claim is presented must have been carried out by a licensed electrician
or installation firm, duly observing all applicable rules. The tank (without outer shell and plastic outer shell) must be protected
from sunshine to avoid discolouring of the PU foam and potential warping of plastic components.
3. The room in which the device is operated must be free of frost. The unit must be mounted in a location that may reasonably be
expected, i.e. it must be possible to access and replace the unit without difficulty for the purpose of necessary maintenance,
repairs and possible replacement. The costs for any necessary changes to the structural conditions (e.g. doors and passages
too narrow) are not governed by the guarantee and warranty declaration and therefore shall be rejected on the part of AE AG.
If the water boiler is set up and operated in uncommon locations (e.g. attics, living rooms with water-sensitive floors, store
rooms, etc.), the possibility of water leakage must be taken into account and provisions made for collecting and discharging
the water leakage in order to prevent secondary damage within the meaning of product liability.
4. The following is not covered by the warranty and guarantee:
inappropriate transport, normal wear and tear, intentional or negligent damage, use of force of any kind or description, mecha-
nical damage or damage caused by frost or also by exceeding the operating pressure stated on the rating plate, even if only
once, use of connection fittings that do not comply with the standard, use of defective tank connection fittings and unsuitable
and defective service fittings. Breaking of glass and plastic components, possible colour differences, damage due to improper
use, in particular non-observance of the mounting and operating instructions (Operating and Mounting Instructions), damage
by external influence, connecting to incorrect voltage, corrosion damage as a consequence of aggressive waters (water not
suitable for drinking) in accordance with the national regulations (e.g. Austrian ordinance on drinking water, TWV – Fed. Law
Gazette II No. 304/2001), deviations between the actual drinking water temperature at the tank fitting and the specified hot
water temperature of up to 10°K (hysteresis of the controller and possible cooling due to pipelines), Insufficient water conduc-
tivity (min. 150 µs/cm) operational wear of the magnesium anode (wearing part), natural formation of boiler scale, lack of water,
fire, flood, lightning, overvoltage, power failure or other types of force majeure. Use of non-original and company-external
components such as e.g. heating elements, reactive anode, thermostat, thermometer, ribbed tube heat exchanger, etc., Parts
installed in an uninsulated condition with respect to the storage tank, ingress of foreign particles or electrochemical influences
(e.g. mixed installations), failure to observe the design documents, unpunctual and undocumented renewal of the installed
protective anode, no or improper cleaning and operation, as well as any deviations from the standard that reduce the value or
functionality of the device only slightly. Fundamental compliance with all regulations in ÖNORM B 2531, DIN 1988 (EN 806),
DIN 1717, VDI 2035 or the corresponding national regulations and laws must be ensured.
5. In the case of an authorised complaint, this must be reported to the next available customer service location of AE AG. The
same reserves the right to decide whether a defect component shall be replaced or repaired or whether a defect device shall
be replaced by an equivalent fault-free device. Furthermore, AE AG explicitly reserves the right to request that the rejected
device be returned by the buyer.
6. Repairs under warranty must be performed exclusively by persons authorised to do so by AE AG. Replaced parts shall remain
the property of AE AG. If a repair of the hot water heater should be required in connection with necessary service work, the
Manufacturer shall invoice these as repair and prorated material costs.
7. Any intervention by third parties without our express instruction, even if performed by a licensed electrician, shall have the
effect of voiding the warranty. Costs for repairs carried out by third parties shall be replaced only if AE AG has previously been
requested to remove the defect and if AE AG shall have failed to satisfy its obligation to replace the defective item or repair the
defect or if it shall have failed to do so within a reasonable period of time.
8. Neither the performance of works under warranty or guarantee, nor the performance of service and maintenance works shall
renew or extend the term of warranty.
9. Transport damage shall be investigated and possibly accepted only if it is reported to AE AG in writing on the next following
workday after delivery at the latest.
10. Claims over and above the warranty, if legally permissible, in particular claims with respect to compensation of damages
and consequential damages, shall be excluded. Prorated labour time for repairs as well as the costs of restoring the original
condition of the unit must be paid in full by the buyer. In accordance with this warranty declaration, the warranty shall apply
only to repair or replacement of the unit. The provisions of the Terms and Conditions of Sale and Delivery of AE AG shall, unless
amended by these Terms and Conditions of Warranty, remain fully in place.
11. Services that are not performed within the scope of these Terms and Conditions of Warranty shall be charged.
12. No claims under warranty shall be considered by AE AG unless full payment for the device has been made to AE AG and
unless the claimant has fully satisfied all obligations arising to him vis-à-vis the seller.
13. The enamelled internal boiler for water heaters is warranted for the specified period from the delivery date provided all
warranty terms described under Points 1 to 12 are observed with in full. If the warranty terms have not been met, the legal
warranty requirements of the respective country from which the appliance was shipped shall prevail.
14. With regard to the assertion of claims pursuant to the Austrian Product Liability Act it must be noted:
Potential claims under the title of product liability relating to the regulation of damages due to a defective product (e.g. a
human’s body is injured, his health is damaged or any corporeal property differing from the product is damaged) shall only be
justified if all the prescribed measures and requirements for flawless and normal operation of the unit have been fulfilled.
These include e.g. the mandatory and documented anode replacement, the connection to the correct operating voltage, any
damage due to improper use must be avoided, etc. These standards are based on the assumption that if all the regulations
(standards, assembly and operating instructions, general guidelines, etc.) are observed, the defect in the unit or product causal
for occurrence of the secondary damage would not have occurred. It is further imperative that all the documentation necessary
for handling of a claim, such as e.g. the type and fabrication number of the unit, the vendor’s invoice and the invoice of the
licensed electrician or installation firm, as well as a description of the malfunction be provided, as well as the defective unit
itself for examination in the lab (absolutely necessary, as the unit will be investigated by an expert and the cause of the defect
analysed). In order to exclude any possibility of mistaken identity of the unit during transportation, the unit must be labelled with
a clearly legible label (ideally with the end customer’s address and signature). Appropriate photographic documentation of the
extent of damage, the installation (cold water inflow, hot water outflow, heating inflow and outflow, safety fittings, expansion
vessel if applicable), as well as the defective part of the tank is required. AE AG further expressly reserves the right to demand
the submission of documentation and units or unit components by the buyer for the purpose of clarification.
The damaged party’s full burden of proof that the damage was caused by the product of AE AG is prerequisite for the payment
of any benefits under the title of product liability. Claims for damages pursuant to the Austrian Product Liability Act are moreo-
ver justified only for any amount exceeding the amount of 500 euros (deductible amount). Until all the facts and circumstances
as well as the problem causally underlying the defect have been ascertained, any possible fault on the part of AE AG shall be
ruled out explicitly. Any non-observance of the operating and assembly instructions as well as the relevant standards shall be
deemed negligence and shall result in an exclusion of any liability for damages.
The figures and data are not binding and may be amended without notice in the interest of technical improvement.
Misprints and technical changes reserved.
Head office and factory:
Austria Email AG
A-8720 Knittelfeld, Austriastraße 6
Telefon: (03512) 700-0
Fax: (03512) 700-239
Internet: www.austria-email.at
E-Mail: [email protected]
Werkskundendienst
Telefon: (03512) 700-297
E-Mail: [email protected]
Sales offices:
Wien, Niederösterreich, Burgenland
A-1230 Wien, Zetschegasse 17
Telefon: (01) 615 07 27
Fax: (01) 615 07 27-260
E-Mail: [email protected]
Steiermark, Kärnten, Osttirol
A-8054 Graz, Dr.-Heschl-Weg 6
Telefon: (0316) 271 869
Fax: (0316) 273 126
E-Mail: [email protected]
Oberösterreich, Salzburg
A-4600 Wels, Gärtnerstraße 17
Telefon: (07242) 45 071
Fax: (07242) 43 650
E-Mail: [email protected]
Tirol, Vorarlberg
A-6020 Innsbruck, Etrichgasse 24
Telefon: (0512) 347 951
Fax: (0512) 393 353
E-Mail: [email protected]