AWS AMW-50 Operation & User’s Manual

Specifications

Brand: AWS
Category: Scales
Model: AMW-50 (Operation & User’s Manual)
File Type: PDF
File Size: —
Pages: 6

Read Online

Read the AWS AMW-50 Operation & User’s Manual online using the built-in PDF viewer.

Text of the manual

American Weigh Scales, Inc.

AMW-50 AMW-150 AMW-250 AMW-500 User Manual AMW Series D i g i t a l P o c k e t S c a l e

AMW Series Manual

Thank you for purchasing the American Weigh AMW-Series digital scale. Please read all operating instructions carefully before use. This electronic scale is a precision instrument. With normal care and proper treatment, it will provide years of reliable service. Never load the scale with more than the maximum capacity. Overloading will permanently damage it! Avoid any exposure to extreme heat or cold. Your scale works better when operated at normal room temperature. Always allow the scale to acclimatize to normal room temperature for at least one hour before use. Give your scale suffi cient warm up time. Usually 30-60 seconds before calibration to give the internal components a chance to stabilize. Keep your scale in a clean environment. Dust, dirt, moisture, vibration, air currents and a close distance to other electronic equipment can all cause an adverse effect on the reliability and accuracy of your scale. Handle with care. Gently apply all items to be weighed onto tray top. Although this scale is designed to be quite durable, try to avoid rough treatment as this may permanently damage the internal sensor. Avoid shaking, dropping or otherwise shocking the scale. This is a precision instrument and must be handled with extreme care. Only operate the scale on a stable, vibration free surface.

Place Scale on a horizontal fl at surface.

1. Press [ON/OFF] key. 2. Wait until "0.0” is displayed. 3. Put the object(s) on the weighing platform. 4. Using the [MODE] key, you can switch between the weighing units. II. TARE WEIGHING 1. Turn on scale as described above. 2. Place the "tare item" on the platform. 3. Press [TARE] and wait until "0.0" is displayed. 4. Add the "net-weight-item". III. CALIBRATION Calibration is NOT required before fi rst use. Only calibrate if scale is not weighing properly. **Make sure you use the correct calibration weight for your scale or the calibration will not be accurate** AMW-50: 50g calibration weight AMW-150: 100g calibration weight AMW-250: 200g calibration weight AMW-500: 500g calibration weight Calibration Procedures for AMW-150, 250, 500 (AMW-50 Calibration Procedures on next page) 1, Turn OFF the scale, press and hold the [CAL] key and then press [ON/OFF] shortly. After 1-2 seconds, the scale will display a random number. Now release the [CAL] key. 2, Wait 2 seconds and press [ON/OFF] key again

3, The LCD display will read “2ero” followed by the

amount of weight required to calibrate (listed above). 4. Place the required calibration weight on the platform (ie. AMW-150 place a 100g on the scale) 5. Press [ON/OFF] again. The LCD display reads “CAL”, then “PASS”. 6. Remove the weight and press [ON/OFF] to turn off the scale. Finished! Repeat if needed. Calibration Procedures for AMW-50 1. Turn OFF the scale. 2. Press [ON/OFF] shortly. Then immediately press and hold [MODE] until “CAL” is displayed. Release the [MODE] key. 3. Press [MODE] again. Now the display will show “CAL” and “50.00” will fl ash 3 times. 4. Place a 50g weight on the center of platform. Wait 3-4 seconds. The LCD display will read “PASS”, then “50.00”. 5. Remove the weight and press [ON/OFF] to turn off the scale. Finished! Repeat if needed. Please check the availability of weights at the store you bought your scale from.

The primary reasons for inaccuracy or malfunction

are low batteries, incorrect calibration, overload or operating on an unstable surface. Please keep this in mind and maintain and operate your scale properly. This scale is a precise instrument and must be handled with the utmost care and caution. [Display] Elimination of errors Nothing, Battery-Symbol, [lo] or [88888] Change the batteries. [OUE2] Recalibrate the scale as shown above. [EEEEE] You are overloading the scale. Remove the excessive load immediately! [LLLLL] The delicate weighing load cells have been damaged by misusing the scale (i.e. it was shocked, dropped or overloaded). You can try recalibrating the scale. If the load cell has not been damaged too much it will work again after recalibration. [UNST] Use the scale in a more stable position

0.1g / 0.005oz / 0.005ozt / 0.1dwt

0.01g 0.001oz 0.05ct 0.2gn Backlight • • • • Calibration Weight (not Included) 100g 200g 500g 50g Platform Dimensions (inches) 2.5 x 3 (Stainless Steel on AMW500 ONLY) Stainless Steel on AMW500 ONLY) Stainless Steel on AMW500 ONLY Scale Dimensions (inches) 5 x 3 x 0.75 Power 2 x AAA Batteries (included) Gross Weight 0.36 lb 0.43 lb 0.36 lb Specifi cations