Quick Installation Guide

CheetahSwitch Workgroup-3024 High-Density Fast Ethernet Switch with 16 10BASE-T/100BASE-TX ports, and 2 slots for 4-port slide-in modules with 10BASE-T/100BASE-TX or 100BASE-FX ports Copyright © 1998 by Accton Technology Corporation. All rights reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written consent of Accton Technology Corporation. Accton makes no warranties with respect to this documentation and disclaims any implied warranties of merchantability, quality, or fitness for any particular purpose. The information in this document is subject to change without notice. Accton reserves the right to make revisions to this publication without obligation to notify any person or entity of any such changes. International Headquarters USA Headquarters No. 1 Creation Road III, P.O. Box 51420 Science-based Industrial Park Irvine, CA 92619-1420 Hsinchu 300, Taiwan, R.O.C. Phone Numbers - Phone: 886-3-5770-270 Sales: 888-398-2101 or 949-707-4800 FAX: 886-3-5770-267 Support: 888-398-4101 or 949-707-4847 BBS: 886-3-5770-654 RMA: 888-398-3101 or 949-707-4828 Internet: [email protected] FAX: 949-707-2460 Accton is a trademark of Accton Technology Corporation. Other trademarks or brand names mentioned herein are trademarks or registered trademarks of their respective companies. ES3024 E0998-R03 150875-101

Quick Installation Guide

CheetahSwitch Workgroup-3024 1 Contents Introduction 1 Package Contents 1 Description of Hardware 1 Mounting the Switch 2 Stacking Switches on a Flat Surface 2 Mounting Switches in a Rack 2 Installing an Optional Module 2 Connecting the Switch System 3 Making a Connection via an RJ-45 Station Port 3 Making a Connection via an MDI Daisy-Chain Port 3 Making a Connection via a Fiber Optic Port 4 Powering On the Switch 4 Verifying Port Status 5 Verifying System Operation 5 Configuring the Switch 6 Using the Configure Button 6 Selecting Display Modes 6 System Diagnostics 6 Setting the Port Speed and Communication Mode 7 Applications 7 Product Specifications 8 Base Unit 8 Media Expansion Modules 9 Switching Criteria 9 Troubleshooting 9 Diagnosing Switch Indicators 9 Power and Cooling Problems 9 Installation 10 Transmission Mode 10 Port and Cable Assignments 10 RJ-45 Port Description 10 EMI Certification 10 Safety Compliance 12 Warranty 13 Optional Hardware Modules 13 Introduction The CheetahSwitch Workgroup-3024 is a high-density switch that’s perfect for moving large workgroups from conventional 10Mbps Ethernet to multiple-segment 100Mbps Fast Ethernet. This switch delivers dedicated 100Mbps links to each attached LAN segment (independent collision domain) or any PC attached directly to the switch – all with conventional cabling and adapters. It completely eliminates the bottlenecks of shared 10Mbps Ethernet networks by providing a wide bandwidth of up to 2.4 Gbps. This makes it ideal for increasing the throughput of interconnected Ethernet / Fast Ethernet hubs or server farms. Moreover, this switch can further enhance performance by segregating broadcast domains into VLAN Port Groups. The CheetahSwitch Workgroup-3024 has 16 100BASE-TX ports in the base unit. It also provides two slots for optional 4-port media expansion modules, that include 100BASE-TX (10/100 Mbps) or 100BASE-FX (SC/ST type) ports. With both modules installed, this switch can support 24 100Mbps swiched connections. And when using the fiber optic ports, you can easily connect to remote sites up to 2 kilometers (1.24 miles) away. Package Contents The CheetahSwitch Workgroup-3024 includes: • CheetahSwitch Workgroup-3024 (Model No. ES3024) High-Density Fast Ethernet Switch with 16 100BASE-TX Ports, and 2 slots for 4-port slide-in modules with 100BASE-TX or 100BASE-FX ports • Four rubber foot pads • Console cable • Rack mount bracket kit • Quick Installation Guide • AC power cord • Owner registration card Description of Hardware The CheetahSwitch Workgroup-3024 base unit contains 16 100BASE-TX ports. It also has two slots for optional 4-port media expansion modules, including 4 100BASE-TX ports, 4 100BASE-FX ports, or a combination of 2 100BASE-TX and 2 100BASE-FX ports. All 100BASE-TX ports operate at 10 or 100 Mbps, and support auto-negotiation, and half or full duplex. 100BASE-FX ports are fixed at 100Mbps, and only support half or full duplex. All RJ-45 ports support auto-negotiation, so the transmission speed and mode will be automatically set if this feature is also supported by the attached device. Otherwise, the speed and mode can be set for any connection using the Configure button or the console port (on the back of the switch). The following figure shows the components of this switch:

Quick Installation Guide

CheetahSwitch Workgroup-3024 2 3 Mounting the Switch This switch can be placed directly on your desktop, or mounted in a rack. Before you start installing the switch, make sure you can provide the right operating environment, including power requirements, sufficient physical space, and proximity to other network devices that are to be connected. Verify the following installation requirements: • Power requirements: 100 to 240 VAC (± 10%) at 50 to 60 Hz (± 3Hz). The switch's power supply automatically adjusts to the input voltage level. • The switch should be located in a cool dry place, with at least 10 cm. (4 in.) of space at the front and back for ventilation. • Place the switch out of direct sunlight, and away from heat sources or areas with a high amount of electromagnetic interference. • If you intend to mount the switch in a rack, make sure you have all the necessary mounting screws, brackets, bolts and nuts, and the right tools. • Check if network cables and connectors needed for installation are available. Stacking Switches on a Flat Surface The CheetahSwitch can be stacked anywhere there is enough flat space, such as on a table or desktop. 1. Stick the self-adhesive rubber foot pads (that come with this package) on each of the 4 concave spaces located on the bottom of the first switch. 2. Place the first switch on a firm flat surface where you want to install the stack. 3. Repeat step 1 for each switch before stacking them. The rubber foot pads cushion the switch against shock/vibrations and provide space between each switch for ventilation. Mounting Switches in a Rack Please comply with the following instructions to ensure that your switch is securely mounted in the rack. 1. Use a standard EIA 19-inch rack. 2. Use the brackets and screws supplied in the rack mounting kit. 3. Use a cross-head screwdriver to attach the brackets to the side of the switch. 4. Position the switch in the rack by lining up the holes in the brackets with the appropriate holes on the rack, and then use the supplied screws to mount the switch in the rack. Installing an Optional Module The two upper slots on the front of the switch are provided for installing an optional media expansion module. The twisted-pair module can be used to expand the number of basic connections provided by the switch, while the fiber optic modules are used to connect to a remote site. You can install a module as described below: 1. Disconnect power to the switch (i.e., modules are not hot-swappable). 2. Remove the face plate on the expansion slot (or a previously installed module) by removing the two screws with a flat-head screwdriver. 3. Before opening the package that contains the module, touch the bag to the switch casing to discharge any potential static electricity. 4. Remove the module from the anti-static shielded bag. 5. Holding the module level, gently push it all the way into the expansion slot, ensuring that it firmly engages with the connector. 6. If you are sure the module is properly mated with the connector, tighten the retainer screws to secure the module in the expansion slot. I Media expansion modules are not hot-swappable. Be sure you power off the switch before installing any of these modules. Connecting the Switch System The CheetahSwitch provides 16 RJ-45 ports on the base unit, and supports up to 8 more RJ-45 ports with the media expansion modules. Each of these ports support connection to 10Mbps Ethernet or 100Mbps Fast Ethernet, and supports full or half- duplex operation. The transmission speed for each port is automatically set by the switch to match the highest speed supported by the connected device. The transmission mode can be set for each port using auto-negotiation (if also supported by the attached device). However, if the device attached to any port on the switch does not support auto-negotiation, you can manually configure the transmission mode using the Configure button or the console interface. Making a Connection via an RJ-45 Station Port You can connect any RJ-45 (MDI-X) station port on the switch to any device that uses a standard network interface such as a workstation or server, or to a network intercon- nection device such as a bridge or router (depending on the port type implemented). 1. Prepare the network devices you wish to network. Make sure you have installed 10BASE-T or 100BASE-TX network interface cards for connecting to the switch's RJ-45 (MDI-X) station ports. 2. Prepare straight-through shielded or unshielded twisted-pair cables with RJ-45 plugs at both ends. Use 100W Category 3, 4 or 5 cable for standard 10Mbps Ethernet connections, or 100W Category 5 cable for 100Mbps Fast Ethernet connections. 3. Connect one end of the cable to the RJ-45 port of the network interface card, and the other end to any available (MDI-X) station port on the switch. All the RJ-45 ports support 10Mbps and 100Mbps Ethernet connections. When inserting an RJ-45 plug, be sure the tab on the plug clicks into position to ensure that it is properly seated. Using the switch in a stand-alone configuration, you can network up to 24 end nodes. I Do not plug a phone jack connector into any RJ-45 port. This may damage the switch. Instead, use only twisted-pair cables with RJ-45 connectors that conform with FCC standards. Notes: 1. Make sure each twisted-pair cable does not exceed 100 meters (328 feet). 2. We advise using Category 5 cable for all network connections to avoid any confusion or inconvenience in the future when you upgrade attached devices to Fast Ethernet. Making a Connection via an MDI Daisy-Chain Port To make a direct connection to another compatible switch or hub, follow these steps: 1. Use an RJ-45 daisy-chain port on one of the expansion modules (if available). Set the daisy-chain switch to MDI. 2. Prepare straight-through shielded or unshielded twisted-pair cables with RJ-45 plugs at both ends. Use 100W Category 3, 4 or 5 cable for standard 10Mbps Ethernet connections, or 100WCategory 5 cable for 100Mbps Fast Ethernet connections.

Quick Installation Guide

CheetahSwitch Workgroup-3024 4 5 3. Connect one end of the cable to an MDI port on the switch, and the other end to any MDI-X station port on the other device. When inserting an RJ-45 plug, be sure the tab on the plug clicks into position to ensure that it is properly seated. Notes: 1. Alternatively, you can connect from an MDI-X port on the switch to an MDI daisy-chain port on the other device. 2. Make sure each twisted-pair cable does not exceed 100 meters (328 feet). 3. To connect to another switch or hub, you may also attach to (MDI-X) station ports at both ends if you use crossover cabling. Restrictions on Cascade Length - The IEEE 802.3 standard recommends restricting the number of hubs (i.e., repeaters) cascaded via twisted-pair cable to 4; while IEEE 802.3u provides even stricter recommendations for Fast Ethernet. Therefore, when cascading devices other than this switch, please refer to the accompanying documentation for cascade restrictions. However, note that because switches break up the path for connected devices into separate collision domains, you should not include the switch or connected cabling in your calculations for cascade length involving other devices. Making a Connection via a Fiber Optic Port If you need to connect fiber cable to the switch, several different 100BASE-FX expansion modules are available that support either SC and ST type connectors. Note that all fiber optic ports operate at 100 Mbps, and are configurable to full or half duplex. Prepare fiber optic cable with SC or ST connectors at both ends. When connecting the module directly to an end-node device (e.g., a workstation or file server), run cable from the Rx (Tx) port on the module to the Tx (Rx) port on the target device. When inserting the cable, be sure the tab on the plug clicks into position to ensure that it is properly seated. When using full duplex, you can run a fiber optic link up to 2 kilometers (1.24 miles). However, when using half duplex, you can only run a link up to 412 meters (0.25 miles). I The 4-port expansion modules are not hot-swappable. Be sure you power off the switch before installing any of these modules. Distance Limit in Fiber Optics Note that as a general rule, the length of fiber optic cable for a single switched link should not exceed 2 kilometers (1.24 miles). However, timing constraints must also be considered when calculating the maximum cable length for your specific environment. Collision Domain Timing Constraints - Where fiber optic cable and twisted-pair links exist in a single collision domain with other repeater devices, the fiber length has to be limited to satisfy Fast Ethernet timing constraints. Use the following table as a guide for maximum fiber length with the listed topologies (IEEE802.3u). le d o M y g o l o p o T c is a B r e b i F .x a M h t g n e L x elp u d lluf - k niL d e h cti w S elg ni S ) s eli m 4 2.1( m K 2 x elp u d fla h - )t e ef 1 5 3 1( m 2 1 4 yln o s k nil X F / X T - r eta e p e R I s s al C hti W )t e ef 4 2 5( m 0 6 1 tn e s er p s k nil 4 T y n a fi - )t e ef 9 2 4( m 1 3 1 yln o s k nil X F / X T - r eta e p e R II s s al C 1 hti W )t e ef 2 8 6( m 8 0 2 yln o s k nil X F / X T - sr eta e p e R II s s al C 2 hti W )t e ef 4 6 3( m 1 1 1 Powering On the Switch 1. Plug the power cord into the power socket at the rear of the switch, and the other end into a power outlet. 2. Check the LED marked PWR on the front panel to see if it is on. The unit will automatically select the setting that matches the connected input voltage. Therefore, no additional adjustments are necessary when connecting it to any input voltage within the range marked on the rear panel. 3. The switch performs a self-diagnostic test upon power-on. (Note that this test takes about 10 seconds to complete.) Notes: 1. The unit supports a "hot remove" feature which permits you to connect/ disconnect RJ-45 or fiber optic cables without powering off the switch and without disrupting the operation of the devices attached to the switch. 2. However, the optional slide-in modules are not hot-swappable. Be sure the switch is powered off when installing or removing these modules. Verifying Port Status Check each connection by viewing the port status indicators shown in the following figure and table. D E L etat S n oita cid nI R W P n O .re w o p g nivie c er si h ctiw S s utatS n O .d etc ele s e d o m y alp sid s utats tro P % LIT U n O ) % + 5 6 ,5 3 ,0 1 ,1(ta n oita zilitu tro p s y alp siD o m e D n O .rota cid ni D E L yre v e sts e T G AID n O .stn e n o p m o c roja m sts e T tc ele S n O ot e d o m n ois si m s n art d n a ,s p b M 0 0 1/0 1 ot d e e p s tro p ste S .n oitaito g e n-otu a ro x elp u d fla h/lluf elo s n o C n O .tro p elo s n o c e ht ot d etc e n n o c si e civ e d e vitc a n a fi s eta cid nI L O C g nih s alF .e m it e m a s e htta ti m s n art ot d etp m etta s e civ e d ero m ro o w T ).D C /A M S C re d n u n oita utis la m ro N ( M 0 0 1 n O .s p b M 0 0 1 ta otte s n e e b e v a h s n oita cin u m m o C X R /X T g nih s alF .tro p e ht g nisre v art si ciffarT llu F n O .x elp u d lluf otte s n e e b e v a h s n oita cin u m m o C k niL/tc ele S n O .n oitc e n n o c kro wte n dila v a d e h silb ats e s a h tro P Verifying System Operation Verify that all attached devices have a valid connection. The switch monitors the link status for each port. If any device is properly connected to the switch and transmitting a link beat signal, the Link indicator will light up for the corresponding port. If the Link indicator fails to light when you connect a device to the switch, check the following items: • Both sides of each connection must use the same transmission mode (i.e., half or full duplex). If any device connected to an RJ-45 port must operate at full duplex, be sure it supports auto-negotiation. If it does not, then manually set the communication mode for the switch port using the Configure button or a console connection.

Quick Installation Guide

CheetahSwitch Workgroup-3024 6 7 • Be sure all network cables and connectors are properly attached to the connected device and the switch. • See if your cable is functioning properly by using it for another port and attached device that displays valid indications when connected to the network. • Be sure no twisted-pair cable exceeds 100 meters (328 feet). Configuring the Switch The transmission mode for all ports must be set to the same mode used by the connected device (i.e., half or full duplex). The fiber optic ports must be manually configured, but the RJ-45 ports can use auto-negotiation to set the transmission mode. However, if any device connected to an RJ-45 port must operate at full duplex, be sure it supports auto-negotiation. If it does not, then manually set the communication mode for the switch port using the Configure button or a console connection. Using the Configure Button Use the Configure button to set the display mode, perform diagnostics or a demonstration, and configure the communication mode. Use a long press (2 seconds) on the Configure button to initiate mode selection, then use a short press (less than 1 second) to move from one mode to the next. The following functions are accessed in sequence: Port Status Displays the status of each port during normal operation - including collision, transmit, receive and link indications. Bandwidth Utilization Shows the percentage of LAN bandwidth utilized. Demonstration Lights all indicator LEDs to verify operation. Diagnostics Tests the status of various system components. Select Mode Sets communication mode to auto-negotiation; or sets the communication mode to half/full duplex and speed to 10/100 Mbps. Selecting Display Modes Port Status mode is the default. When this LED is lit, the indicators provide information on packet collisions (for ports set at half duplex), communication speed, port activity, communication mode, and link status. Bandwidth Utilization mode (UTIL%) uses the whole LED display to indicate values (1% to 65+%) for each port. When active, these LEDs behave like a stereo's equalizer display. System Diagnostics Enabling the DIAG function activates a two-stage self-diagnostic test, similar to the one performed upon power on. The first stage is the System Diagnostic Test, and the second stage is the Port Diagnostic Test. If the test is not completed successfully, the corresponding LEDs (described below) will blink after test completion to indicate which component failed the test. Setting the Port Speed and Communication Mode When the Select LED is lit, use a long press to activate configuration. Note that when the Configure button is released, the current communication mode selections are displayed by the 100M and Full LEDs for each port (as indicated in the following table), and the Select LED for Port 1 will begin to blink. To change modes, use a short press on the Configure button and then use a long press to implement the setting and move on to the next port. When finished, use a long press to terminate configuration. The switch also includes a menu-driven configuration program which can be accessed by attaching a VT100 compatible terminal or a PC running a terminal emulation program to the console port on the back of the switch. Use the null-modem cable provided with this package, or use a null modem connection that complies with the wiring assignments shown in the back of this guide. When attaching to a PC, set terminal emulation type to VT100, specify the port used by your PC (i.e., COM 1~4), and then set communications to 8 data bits, 1 stop bit, no parity, and 9600 bps (for initial configuration). Also be sure to set flow control to "none." Once a direct connection to the console port is established, you will have access to the menu items shown below. m etI u n e M n oitpirc s e D 4 2 5 3 S E tu o b A .dra o b U P C d n a dra o b nia m tu o b a n oita m rofni n oisre v s y alp siD n oitaru gifn o C tro P .e d o m x elp u d d n a d e e p s n ois si m s n art ste S g nip u or G tro P N A L V .)g nip p alre v o htiw ( s p u org 4 2 ot p u ot stro p s n gis s A d a oln w o D M E D O M X . m ets y s ru o y eta d p u ot era w m riffo n oisre v w e n s d a oln w o D dro w s s a P re s U .dro w s s a p re s u ste S n oitaru gifn o C elo s n o C .tu o e m it d n a etar d u a b elo s n o c ste S te s e R . m ets y s e ht strats e R Notes: 1. Factory defaults are auto-negotiation for RJ-45 ports, and 100Mbps and half duplex for fiber optic ports. 2. Full duplex can only be used for a dedicated link. When connecting to a shared collision domain (e.g., a repeater hub), half duplex must be used. 3. This switch uses the Nways standard for auto-negotiation. 4. Factory default has all ports in VLAN Group 1, with all other groups empty. Applications This switch segments your network, significantly increasing both bandwidth and throughput. Any port on the switch can be attached to a hub (i.e., shared collision domain) or provide a dedicated link to a single network device (e.g., a workstation). When a port on the switch is connected to a hub (i.e., a 10 or 100 Mbps repeater), the bandwidth provided by that port is shared by all the devices connected to the attached hub. However, when a port is connected to an end node or to a device that breaks up the collision domain (e.g., another switch, bridge or router), the attached device has access to the full bandwidth provided by that port. Bridging Functions - This switch provides fully transparent bridging functions. It automatically learns node addresses, that are subsequently used to filter and forward all traffic based on the destination address. When traffic passes between devices attached to the same shared collision domain, those packets are filtered from the switch. But when traffic must be passed between unique segments (i.e., different ports on the switch), the high-speed switching fabric forwards the packets at near zero latency. e d o M /d e e p S r ota cid nI D E L M 0 0 1 llu F x elp u d fla h ,s p b M 0 1 ffo ffo x elp u d lluf,s p b M 0 1 ffo n o x elp u d fla h ,s p b M 0 0 1 n o ffo x elp u d lluf,s p b M 0 0 1 n o n o n oitaito g e n-otu a g nih s alf g nih s alf d ets e T tn e n o p m o C r ota cid nI D E L M O R m ets y S s utatS M A R m ets y S % LIT U M O R P E E m ets y S o m e D tro P tc ele S re vie c s n arT llu F CI h ctiw S k niL M A R S S CI h ctiw S M 0 0 1 elb a T n oitulo s e R s s erd d A elo s n o C

Quick Installation Guide

CheetahSwitch Workgroup-3024 8 9 Switching Functions - Store-and-forward switching is used to forward traffic to other ports. This scheme ensures data integrity and provides a clean data stream. Flexible Configuration - This switch is not only designed to segment your network, but also to provide a wide range of options in setting up network connections. It can be used as a simple stand-alone switch; or can be connected with standard repeater hubs, switches, or other network interconnection devices in various configurations. Product Specifications Base Unit Access Method CSMA/CD, 10 Mbps or 100 Mbps Standards Conformance IEEE 802.3, IEEE 802.3u Communication Rate 10/100 Mbps Communication Mode Full or half duplex Media Supported 10BASE-T - 100WCategory 3,4,5 twisted-pair 100BASE-TX - 100WCategory 5 twisted-pair Number of Ports 16 RJ-45 100BASE-TX ports Indicator Panel System: Power, status, utilization, demo, diagnostics, console Ports: Collision, 100M, TX/RX, full/half duplex, select/link System Configuration Push-button: sets indicator functions, and configures transmission mode to half/full duplex or auto-negotiation Console connection: same as push-button, and configures VLAN Port Groups Dimensions 440 x 305 x 63 mm (17.32 x 12.0 x 2.48 in) Weight 4.1 kg (9.04 lb) Input Power Full range: 100 to 240V (±10%), 50 to 60 Hz (±3Hz) Power Consumption 45 Watts max. @ 100-240 VAC Heat Dissipation 153.5 BTU/hr max. @ 100-240 VAC Temperature Operating: 0~40°C / 32~104°F, Storage: -40~70°C / -40~158°F Humidity 5% to 95% (non-condensing) Certification CE Mark Emissions FCC Class B, VCCI Class B, CISPR Class B Immunity IEC 1000-4-2/3/4/6 Safety CSA/NRTL, TÜV/GS Media Expansion Modules 100BASE-TX Ports (EM3564-TX, EM3564-TF-SC, EM3564-TF-ST) Access Method CSMA/CD, 10 or 100 Mbps Standards Conformance IEEE 802.3u 100BASE-TX Communication Rate 10 or 100 Mbps (manual or auto-detection) Communication Mode Full or half duplex (manual or auto-negotiation) Media Supported 100BASE-TX 100W Cat 5 for 100 Mbps, or 100W Cat 3,4,5 for 10 Mbps Number of Ports Up to 4 RJ-45 10BASE-T / 100BASE-TX ports Indicator Panel Included on base unit 100BASE-FX Ports (EM3564-FX-SC, EM3564-FX-ST, EM3564-TF-SC, EM3564-TF-ST) Access Method CSMA/CD, 100 Mbps Standards Conformance IEEE 802.3u 100BASE-FX Communication Rate 100 Mbps Communication Mode Full or half duplex (manual) Media Supported 50/125 mm or 62.5/125 mm multimode fiber Number of Ports Up to 4 RJ-45 100BASE-FX SC or ST ports Indicator Panel Included on base unit Switching Criteria Network Bridging Function Filtering, forwarding and learning Switching Method Store-and-forward Address Table 8K entries per system Queue Buffer 128K bytes per port Address Resolution Fast hashing scheme Filtering/Forwarding Rate Line speed Troubleshooting Diagnosing Switch Indicators The switch can be easily monitored through panel indicators to assist the network manager in identifying problems. This section describes common problems you may encounter and possible solutions. Symptom: Link indicator does not light up (green) after making a connection. Cause: Network interface (e.g., a network adapter card on the attached device), network cable, or switch port is defective. Solution: Verify that the switch and attached device are powered on. Be sure the cable is plugged into both the switch and corresponding device. Verify that the proper cable type is used and its length does not exceed specified limits. Check the adapter on the attached device and cable connections for possible defects. Replace the defective adapter or cable if necessary. Symptom: Power indicator does not light up (green) after power on. Cause: Defective power outlet, power cord, or internal power supply. Solution: Check the power outlet by plugging in another device that is functioning properly. Check the power cord with another device. If these measures fail to resolve the problem, have the unit's power supply replaced by a qualified Accton distributor. Power and Cooling Problems If the power indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or internal power supply as explained in the previous section. However, if the unit powers off after running for a

Quick Installation Guide

CheetahSwitch Workgroup-3024 10 11 while, check for loose power connections, power losses or surges at the power outlet, and verify that the fans on back of the unit are unobstructed and running prior to shutdown. If you still cannot isolate the problem, then the internal power supply may be defective. In this case, contact your Accton distributor for assistance. Installation Verify that all system components have been properly installed. If one or more components appear to be malfunctioning (e.g., the power cord or network cabling), test them in an alternate environment where you are sure that all the other components are functioning properly. Transmission Mode Verify that each port is set to the same transmission mode used by the attached device (i.e., half or full duplex). You can configure the ports using the Configure button or a console connection. RJ-45 ports can use auto-negotiation to set the transmission mode. However, if the attached device does not support auto-negotiation, then you may have to manually configure the port. Port and Cable Assignments RJ-45 Port Description RJ-45 station ports (MDI-X) can be attached to any devices which use a standard network interface (e.g., a workstation, server, bridge or router). RJ-45 daisy-chain ports (MDI) can be cascaded to a station port on similar networking devices (e.g., another switch or hub). Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for RJ-45 connections: 100W Category 3, 4 or 5 cable for 10 Mbps connections or 100W Category 5 cable for 100 Mbps connections. Also be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet). ni P tn e m n gis s A )str o P n oitat S ( tn e m n gis s A )tr o P nia h C -y sia D ( 1 + ata D e vie c e R tu p nI + ata D ti m s n arT tu ptu O 2 - ata D e vie c e R tu p nI - ata D ti m s n arT tu ptu O 3 + ata D ti m s n arT tu ptu O + ata D e vie c e R tu p nI 6 - ata D ti m s n arT tu ptu O - ata D e vie c e R tu p nI 8,7,5,4 d e s U to N d e s U to N Schematics for both straight and crossover twisted-pair cable are shown below. h g u o r h T -t h g ia rt S r e v o s s o r C )h cti w S ( )r etp a d A ( )h cti w S ( )h cti w S ( + D R I 1 + D T O 1 + D R I 1 + D R I 1 - D R I 2 - D T O 2 - D R I 2 - D R I 2 + D T O 3 + D R I 3 + D T O 3 + D T O 3 - D T O 6 - D R I 6 - D T O 6 - D T O 6 EMI Certification FCC Class B (USA) Accton Technology Corporation Model Number: ES3024 This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Warning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from the one which the receiver is connected to • Consult the dealer or an experienced radio/TV technician for help You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. Note: In order to maintain compliance with the limits of a Class B digital device, Accton requires that you use a quality interface cable when connecting to this device. Changes or modifications not expressly approved by Accton could void your authority to operate this equipment. Suggested cable type is: RJ-45: Unshielded or shielded (UTP/STP) cable – Category 3 or greater for 10Mbps connections, and Category 5 for 100Mbps connections, Fiber Optics: 50/125 µm or 62.5/125 µm multimode fiber. Class B (Canada Department of Communications) This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled "Digital Apparatus", ICES-003 of the Department of Communications. Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils numériques de Classe B prescrites dans la norme sur le matériel brouilleur: "Appareils Numérques", NMB-003 édictée par le ministère des Communications. VCCI Class B Compliance (Japan) CE Mark Declaration of Conformance (for EMI and Safety - Europe) This is to certify that this product complies with ISO/IEC Guide 22 and EN45014. It conforms to the following specifications: EMC: EN55022(1988)/CISPR-22(1985) class B IEC1000-4-2(1995) 4kV CD, 8kV AD IEC1000-4-3(1995) 3V/m IEC1000-4-4(1995) 1kV - (power line), 0.5kV - (signal line) IEC1000-4-6(1995) 3Vrms This product complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC.

Quick Installation Guide

CheetahSwitch Workgroup-3024 12 13 Safety Compliance Underwriters Laboratories Inc. (USA) Important! Before making connections, make sure you have the correct Cord Set. Check it (read the label on the cable) against the following specification list. e g a tl o V s n o it a c ifi c e p S t e S d r o C stlo V 0 2 1 te S dro C d eifitre C A S C /d etsiL L U dro c rotc u d n o c e erht T J S ro T V S e p yt; G W A 8 1 m u m ini M te ef 5 1 fo htg n el m u m ix a M V 5 2 1 ,A 5 1 d etar g ulp tn e m h c atta e p yt g nid n u org ,e d alb lellara P stlo V 0 4 2 te S dro C d eifitre C A S C /d etsiL L U )a cire m A htro N ( dro c rotc u d n o c e erht T J S ro T V S e p yt; G W A 8 1 m u m ini M te ef 5 1 fo htg n el m u m ix a M V 5 2 1 ,A 5 1 d etar g ulp tn e m h c atta e p yt g nid n u org ,e d alb m e d n a T stlo V 0 4 2 )yln o e p oru E( htiw srotc u d n o c e erht g niv a h dro c F-V V 5 0 H htiw te S dro C ² m m 5 7.0 fo rete m aid m u m ini m V 0 5 2 ,A 0 1 d etar g ulp ela m ;elc atp e c er 0 2 3- C EI Wichtige Sicherheitshinweise (Germany) 1. Bitte lesen Sie diese Hinweise sorgfältig durch. 2. Heben Sie diese Anleitung für den späteren Gebrauch auf. 3. Vor jedem Reinigen ist das Gerät vom Stromnetz zu trennen. Verwenden Sie keine Flüssigoder Aerosolreiniger. Am besten eignet sich ein angefeuchtetes Tuch zur Reinigung. 4. Die Netzanschlu ßsteckdose soll nahe dem Gerät angebracht und leicht zugänglich sein. 5. Das Gerät ist vor Feuchtigkeit zu schützen. 6. Bei der Aufstellung des Gerätes ist auf sicheren Stand zu achten. Ein Kippen oder Fallen könnte Beschädigungen hervorrufen. 7. Die Belüftungsöffnungen dienen der Luftzirkulation, die das Gerät vor Überhitzung schützt. Sorgen Sie dafür, daß diese Öffnungen nicht abgedeckt werden. 8. Beachten Sie beim Anschluß an das Stromnetz die Anschlußwerte. 9. Verlegen Sie die Netzanschlußleitung so, daß niemand darüber fallen kann. Es sollte auch nichts auf der Leitung abgestellt werden. 10. Alle Hinweise und Warnungen, die sich am Gerät befinden, sind zu beachten. 11. Wird das Gerät über einen längeren Zeitraum nicht benutzt, sollten Sie es vom Stromnetz trennen. Somit wird im Falle einer Überspannung eine Beschädigung vermieden. 12. Durch die Lüftungsöffnungen dürfen niemals Gegenstände oder Flüssigkeiten in das Gerät gelangen. Dies könnte einen Brand bzw. elektrischen Schlag auslösen. 13. Öffnen sie niemals das Gerät. Das Gerät darf aus Gründen der elektrischen Sicherheit nur von authorisiertem Servicepersonal geöffnet werden. 14. Wenn folgende Situationen auftreten ist das Gerät vom Stromnetz zu trennen und von einer qualifizierten Servicestelle zu überprüfen: a. Netzkabel oder Netzstecker sind beschädigt. b. Flüssigkeit ist in das Gerät eingedrungen. c. Das Gerät war Feuchtigkeit ausgesetzt. d. Wenn das Gerät nicht der Bedienungsanleitung entsprechend funktioniert oder Sie mit Hilfe dieser Anleitung keine Verbesserung erzielen. e. Das Gerät ist gefallen und/oder das Gehäuse ist beschädigt. f. Wenn das Gerät deutliche Anzeichen eines Defektes aufweist. 15. Zum Netzanschluß dieses Gerätes ist eine geprüfte Leitung zu verwenden. Für einen Nennstrom bis 6A und einem Gerätegewicht größer 3kg ist eine Leitung nicht leichter als H05VV-F, 3G, 0.75mm2 einzusetzen. Der arbeitsplatzbezogene Schalldruckpegel nach DIN 45 635 Teil 1000 beträgt 70dB(A) oder weniger. Warranty Accton warrants to the original owner that the product delivered in this package will be free from defects in material and workmanship for a period of three (3) years from the date of purchase from Accton or it’s Authorized reseller. For the warranty to apply, you must register your purchase by returning the registration card indicating the date of purchase and including proof of purchase. There will be a minimal charge to replace consumable components, such as fuses, power transformers, and mechanical cooling devices. The warranty does not cover the product if it is damaged in the process of being installed. Accton recommends that you have the company from whom you purchased this product install it. THE ABOVE WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR ANY WARRANTY ARISING OUT OF ANY PROPOSAL, SPECIFICATION OR SAMPLE. ACCTON SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. ACCTON NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY OTHER LIABILITY. Optional Hardware Modules 4-Port Slide-in Modules EM3564-TX 4 10BASE-T/100BASE-TX (RJ-45) Ports EM3564-FX-SC 4 100BASE-FX (SC-Type) Ports EM3564-FX-ST 4 100BASE-FX (ST-Type) Ports EM3564-TF-SC 2 10BASE-T/100BASE-TX (RJ-45), 2 100BASE-FX (SC-Type) ports EM3564-TF-ST 2 10BASE-T/100BASE-TX (RJ-45), 2 100BASE-FX (ST-Type) ports