ADE Barbara BA 914 Instruction Manual
Read Online
Read the ADE Barbara BA 914 Instruction Manual online using the built-in PDF viewer.
Text of the manual
Model Barbara / BA 914
Instruction Manual
Directory
How does the body analyser work?
Page 2
Conditions to use
.
Page 2
Commissioning
Page 3
Programming / enter of personal data
Page 4
Weighing function (weight measurement only)
Page 4
Body Analysis.
Page 5
Error Messages..........
..
Page 6
Technical Data
....Page 7
Warranty
Page 7
This document is hosted by Old Will Knott Scales
www.oldwillknottscales.com
Thank you for your decision to purchase this high-quality body analyser scale. Please
peruse read this instruction manual prior to first start up and keep this user instruction
careful to have this information on hand whenever it is needed.
1. How does the body analyser work?
Through this new revolutionary scale, you will be able to get information about your body
composition with reference to your weight. body fat %, body water %, muscle mass %
and bone mass kg. Rrst of all, you have to enter once your personal data like gender
(male or fennale), age and body height under your selected personal memory location.
Afterwards a measurement is as simple as on a normal bath'oom scale. Afterwards a
measurennent is as simple as on a normal bathroom scale. You have only to select your
personal memory location, step on the scale and within a few seconds, your measured
values will be indicated. The analysis based on the measurement of the body's electrical
resistance. A low, safe electrical signal passes freely through fluids contained in lean
tissue, such as muscle and blood, but meets resistance passing through fat tissue. The
body analyser accurately measures the resistance and with reference to your personal
data use it to calculate elennents of body composrtion.
2. Conditions to use
If possible, the measurement should be done undressed and aMiays barefoot.
By nature, a body is subject of fluctuations (for exarnpkl loss of water after taking
exercise or after a sauna visit, after a meal, etc.). To enable comparable readings rt is
important to take the measurements as possible always under the same conditions.
In order to ensure that the results of analysis are accurate and consistent, please keep
the measurement conditions constant always at the same daytime. In the morning,
directly after you've woken up, your body will be dehydrated and also the majority of fluid
will be stored in the central trunk area. This means that the resistance is relatively high
because of the poor conductivity in the body. By intensify moving during the day
progresses the fluid becomes more evenly distributed through the limbs and increasing
the accuracy of the readings. To get a realistic result it is important to take your readings
at the same time and under the same conditions every day. The easiest way to stick the
rule, measure aMiays in the morning, 15 minutes after you've got up, either before or
after you've gone to the bathroom.
In spite of a very low electrical signal, this body analyzer is not suitable for persons
with heart pacemaker or other electronic medical implants! There is no risk for
persons with none electronic implant for instance a titanium plate in the knee. However,
metal conducts the electric current extrennely well and therefore the scale implicates the
body fat value "beautified" - means the actual body fat value is higher as Indicated.
However, tendencies may be determined as well.
2
Due to menstrual cycle and hormonal changes women experience greater changes in
their hydration level. Retaining fluid may cause the weight to fluctuate day-to-day. This will
also affect the body fat percentage readings. If the hydration level is high, the body fat
percentage is slightly less - a less hydration level means the body fat percentage is slightly
higher.
There is no hea~hy risk for pregnancy. The body analyzer is absolutely safe for the mother
and her unbom baby. However, due to the changes in water content in the mother's
body, the readings should not be interpreted as completely accurate.
ADE Germany takes no responsibility for any damages or losses caused by the use of this
body analyzer scale or for Third party claims. This product is exclusively intencled for
private use. This product is not designed for commercial or professional use in hospitals or
other medk:al facilities.
3. Commissioning
Safety guidelines:
The appliance is not intended for use by persons Oncluding children) with reduced
physk:al, sensory, or mental capabilities, or lack of experience and knowledge, unless a
person responsible for their safety has given them supervision or instruction concerning
use of the appliance. Children should be supervised to ensure that they do not play with
the appliance.
Not
suitable
for
persons
with
electronic
implants
(heart
pacemaker, etc.).
Place
the
scale
on
a
plane
and
firm
surface
(tiles,
hardwood flooring, etc.) to avoid a wrong measurement on
carpeted floor
Attention - Hazard of slipsl Do not stand on the scale with
wet feet or on a slippery surface of the weighing platform.
Please care that no heavy object may fall on the scale. The
glass surface is breakable.
Clean the scale only by using a slightly damp cloth. Do not
use solvents or abrasive cleaning agents. Do not submerge
the scale under water.
Preparation:
Open the battery cover at the bottom side of the scale and remove the battery safety strip.
Please ensure the correct polarity of the battery (+/-).
3
There is a little push button right beside the battery case at the bottom side of the scale
for country specific settings with the optkln to switch from kg = kilogram to Ib = pound or
to st:lb = stone: pound. Please pay attention to use the scale under consk:leration of your
country specific unit of weight.
4. Programming / Enter of personal data
Before first time use your personal data like gencler (female or male), age and body
height must be programmed and saved under selected locations PO - P9 (up to 10
persons). The scale is equipped with highly sensitive touch buttons. The touch buttons
are located below the display. To enter your personal data please utilise the buttons: SET
(on and save button), T (Plus button), ... (minus button) and folaw the particular points:
1. Ughtly touch the SET-button. The display indicates flashing "PO". To select your
personal locatkln (PO - P9), touch the ... - or ..-button. After the selection of your
personal location, touch the SET-button to save the reading.
2. After you've selected your personal location (e.g. P3), the symbol for gencler starts to
flash. To select the requested gender (Y male oni female), touch the ... - or .. -button.
After the selection of your gencler, touch the SET-button to save the reading.
3. After you've selected your gencler (e.g. female), the symbol for age starts to flash
(default age 30). To enter your age, touch the ... - or ..-button. After the selection of
your age, touch the SET-button to save the reading.
4. After you've selected your age, the symbol for body height starts to flash
(defau~
170 em). To enter your body he9ht, touch the ... - or .. -button. After the selection of
your body height, touch the SET-button to save the reading.
The scale indicates once again your selected personal data. That settles the completion
of input and the scale returns to the indication "0.0 kg". The scale is ready to use and
you may now start your body analysis. Without further activ~ the scale automaticaily
power-off. Your personal data are stored.
If you push the ... - or .. -button within 2 seconds after the first complete input, you can
directly enter the personal data of a further person. Altematively, you repeat the complete
steps listed below for further entries of personal data.
5. Weighing function (weight measurement only)
1. Switch-on the scale by using the tap-on-function. For this, tap with your foot short and
firm on the scale. The display indicates all symbols and a few seconds later
"0.0 kg". Now the scale is ready to use.
4
2
3
6
A
s
1
2
3
2. Step on the scale. Remain stationary on the weighing platform and do not hold you
tight.
3. After the scale levelled-off your w"ght wili be indicated successively three times and
then for 10 seconds steady. Afterwards the scale switch-off automatically.
6. Body Analysis
An analysis is only possible in bare feet. Your personal data must be entered first (please
see page 4).
1. Switch-on the scale by touching the SET-button. Please select your personal memory
location (where your personal data area stored) by using the ... - or ... -button. Your
personal data (location, gender, age, and body height) wili be successively displayed.
Confirm these each at a time by touching the SET-button. Afterwards "0.0 kg" will be
indicating.
2. Now, carefully step in bare feet on the four stainless steel electrodes (measuring units)
of the scale and remain stationary.
3. At first, your w"ght will be indicated on the display. Then, while the analysis is taking
place, the indication flashes. After completion of the measurement, your measured
values will be shown twice in a row as foliows:
Your weight in kg - your body fat in %. yOur body water in %, yOur muscle mass in %
and yOur bone mass in kg.
After a few seconds the scale switch-off automatically.
The bocIy fat content is shown as the amount of stored fat as a percentage of total body
weight. There is no generally accepted set value as this varies significantly according to
gender (due to the different build) and age. Body fat is vital for basic body functions. It's
protecting organs, cushioning joints, regulating body temperature, storing vitamins and
serves the bocIy as energy storage. As essential for women a minimum body fat
proportion between 10% and 13% and for men between 10% and 13% is requested -
with the exception of competitive athletes.
Body fat is not a clear indicator for health. Too high body weight and a too high bocIy fat
proportion are linked to the incidence of many civilization diseases such as dialbetes,
cardiovascular diseases, etc. Lack of movement and improper nutrrtion are often the
prime course for these diseases. There is an obvious direct relationship between
overweight and lack of movement.
5
There are no validated standards for muscle mass.
.
Women *
AGE
Body Fat
I BodvWater
sli9htly
overwei"'ht
slim
rormal
overweiaht
rormal
10-16
<18%
18-28%
29-35%
>35%
57-67%
17-39
<20%
20-32%
33-38%
>38%
47-57%
40-55
<23%
23-35%
38-41%
>41%
42-52%
56-85
<24%
24-38%
37-42%
>42%
37-47%
•
Men Y
AGE
Body Fat
BOdVWater
slightly
overwPinht
slim
rormal
overweiaht
rormal
10-16
<10%
10-18%
19-23%
>23%
58-72%
17-39
<12%
12-20%
21-25%
>25%
53-67%
40-55
<13%
13-21%
22-26%
>26%
47-61 %
56-85
<14%
14-22%
23-27%
>27%
42-56%
A significant part of the human body consists of body water. This body water is
differently distributed throughout the whole body. Lean muscle tissue contains approx.
75% body water, blood approx. 83% body water, body fat approx. 25% body water and
bones have a water content of about 22%.
The average total body water percentage range for healthy men is between 50 - 65%.
The equivalent value for women is approximately 45 - 60% due to the higher body fat
content. About two third of the total body water is stored in the ceils and is therefore
called intra ceiluar. The other third of the total body water is extra cellular body water.
S
7. Error Messages
Overioad
-
The weight exceeds the maximum capacity of 150 kg.
Please immediately remove the critical load to avoid load ceil damage.
Batteries are used up - Please repace the batteries with the ntended
type (2 x CR2032).
B
c
v
N
C
6
8. Technical Data
Capacity x graduation:
Display resolution:
Display resolution:
Display resolution:
Display resolution:
Personal memory loc.:
Age:
Body height:
Dimensions:
Batteries:
max. 150 kg x 100 g
body fat: 0.1 %
body water: 0.1 %
muscle mass: 0.1%
bone mass: 100 g
10 positions
10 - 80 years
100-240 em
approx. 300 mm x 300 mm x 34 mm
2 x CR2032 (induded)
Subject to technica modifications
9. Warranty
ADE warrants for a period of 3 years from the date of purchase that it will remedy any
defects due to faulty material or workmanship free of charge by repair or replacement.
When purchasing, please have the warranty coupon signee and stamped by the dlealer.
When making a guarantee claim, please retum the weighing scale together with the
guarantee card including the reason of complaint to your dealer.
CE
CE-Conformity - This device features radio interference
suppression in compliance with valid EC Regulation 2004/108
Note: The displayed valce may be adversely affected under extreme electromagnetic
influences, e.g. when using a radio unil in the immediate vicinity of the device. Once the
interference has been rectifled, the product can once again be used for its intendled
purpose. The device may have to be switched-on again.
Statutory instructions on battery disposal
Batteries must not be disposed as household waste. The law requires that you, as
consumer, retum the waste batteries either to public collection points in your town or
village or to any outlet selling batteries of the same kind.
Note:
Batteries are marked as follows:
U
Battery contains Uthium
AI
Battery contains Alkali
Mn
Battery contains Manganese
CR (U); AA (AI, Mn); AAA (AI, Mn)
7
Safety instructions for lithium batteries (CR20321CR2430):
1. Uthium batteries are lithium manganese cells. If you do not use the scale over a longer
period, you should take out the batteries ot the device.
2. Never open the lithium battery, do not put into fire, or expose to shocks because an
explosion risk lasts or discharge of poisonous exposure to fumes might possible.
3. Never touch leaked cells with bare hands.
4. When eyes or hands are contaminated, it is essential to rinse with lots of water. You
should go to a doctor if skin or eyes are irritated.
5. Dispose cells
on~
complete~
discharged or protected against polarity reversal
wrapped according to your local disposal regulation.
6. Do not expose the cells to direct solar radiation and store away from
heat:
otherwise, there is risk of overheating.
7. Maintain a storage temperature of < 40°C.
Disposal of old electrical and electronic equipment
This symbol on the product or on its packaging indicates that this
product shall not be treated as household waste. Instead It shall be
handed over to the applicable collection point for the recycling of
electrical and electronic equipment. For more detailed information
about recycling contact your local city office, your household waste
disposal service or the shop where you purchased the product.
With kind regards
ADE (GmbH & Co.)
X ----------------------------------------------------------------------------------------------------
Guarantee Card - 3 years warranty for the Body Analysing Scale
~
~
C
C
Please return this guarantee card together with the receipt to your retailer.
• Sender
• Date of purchase
• Reason for complaint
M
M