Draper Nocturne Installation Instructions

Text of the manual

Nocturne™ Exterior Projection Screen by Draper

Copyright © 2012 Draper Inc. Form Nocturne_Inst12 Print ed in U.S.A. ® If you encounter any diffi culties installing or servicing your Nocturne Exterior Projection Screen call your dealer or Draper, Inc. in Spiceland, In di ana, 765-987-7999, or fax 765-987-7142. Caution ① Inspect all boxes to make sure you have received the proper parts. ② Open cartons lengthwise. ③ All hardware must be installed level. Screens must be level and square. ④ Do not wire motors in parallel without written permission from Draper. ⑤ It is the installer’s responsibility to make sure appropriate fasteners are used for mounting surface. ⑥ Please read the following installation guidelines thoroughly and follow them carefully. Failure to do so may cause product to fall or otherwise fail, and invalidates warranty. Continued on next page Before mounting your Nocturne Exterior Projection Screen, mark build- ing for placement of mounting brackets and pre-drill mounting holes and electrical access holes (if necessary) in mounting surface. It is installer’s responsibility to make sure appropriate fasteners are used for mounting surface. The Nocturne Exterior Projection Screen is shipped with screen case assembly complete (see Fig. 1). Mounting Through Back of Screen Case: ① Remove fascia from screen case. If your unit is equipped with a crank operator, fi rst remove the crank attachment from the unit, then remove ad- ditional screws holding fascia onto back/top and rotate fascia up and off of unit (see Fig. 2). Figure 1 Drill holes for wall mounting, using holes in endcaps as guides. Figure 2 ② Drill mounting holes in back of screen case, using holes in endcaps for guides. Holes can also be drilled through the sides of the endcaps for inside mounting (see Fig. 3). If this is a motorized unit, you will also need to drill out a hole for the power and control cable to exit the screen case. Figure 3 Mounting Through Top of Screen Case: ① Remove fascia from screen case. If your unit is equipped with a crank operator, fi rst remove the crank attachment from the unit, then remove ad- ditional screws holding fascia onto back/top and rotate fascia up and off of unit (see Fig. 2). ② Remove screen assembly from screen case. If motorized, remove motor retaining clips. Pull the screen assembly away from the operator end. This will depress the spring-loaded pin on the non-operator end. Then you can rotate screen assembly out of the screen case (Fig. 4). Figure 4 Motorized Crank ③ Drill mounting holes in top of screen case, using holes in endcaps for guides. If this is a motorized unit, you will also need to drill out holes for the power and control cables to exit the screen case. Please Note: It is the installer’s responsibility to make sure appropriate fasteners are used for mounting surface. ④ Replace screen assembly in screen case. Place the spring-loaded pin on the non-operator end into the endcap. Push the screen assembly toward the non-operator end to depress the spring-loaded pin, then rotate screen assembly into the screen case. ⑤ Lower viewing surface approximately 12" to begin guide installation. ⑥ If motorized, replace motor retaining clips (see Fig. 4). Please Note: It is the installer’s responsibility to make sure appropriate fasteners are used for mounting surface. Side Cable Installation (see Fig. 5 on page 2): Please Note: Skip this section if you elect not to install the side cable guides. ① Attach cable deck or wall mount to mounting surface. ② Attach cable to deck or wall mount using provided washer and nut. ③ After making sure of the length required, cut cable and strip the protective jacket from the top 1". ④ Insert cable through the hole provided in the end of the dowel, and then up through hole in endcap. ⑤ Insert stripped-off portion of cable into provided screw jacket, then tighten in place against the side wall of the endcap with the provided screw. Make sure the cable is taut. Tension to 8 in-lbs, so the screen will move up and down easily along the cable. ⑥ Replace fascia and crank operator (if provided). Please Note: A minimum of 1¾" is required for the closure to hinge up, attach and close. Please Note: A minimum of 1¾" is required for the closure to hinge up, attach and close. For fl ush ceiling mount, blocking (max. depth 3") may also be required above screen case to allow closure panel suf- fi cient room to hinge to open/close. 1¾" Min. 3" Max. Wall Clg

Nocturne Exterior Projection Screen by Draper

Page 2 of 4 www.draperinc.com (765) 987-7999 Figure 5 OR Electrical Connections Screen operates on 110-120V, 60 Hz. current. Screen is shipped with internal wiring complete and control switch (es) fully boxed, and supplied with a 6' cable lead. Longer lead can be substituted by removing two screws in motor end of roller, removing lead, plugging new lead in, and replacing screws. Wire to connect shade to switch (es) and switch (es) to power supply should be fur- nished by installer. Con nec tions should be made in ac cor dance with attached wiring diagram, and wiring should comply with national and local electrical codes. DO NOT wire motors in parallel without written permission from Draper. All operating switches should be “off” before power is connected. Limit Switch Adjustments—Standard Motor Push Button Limits ① Fully depress both limit switch push buttons, then operate wall switch to make sure system works properly. ② Raise screen to desired “up” stop position. ③ Set upper limit by depressing and releasing the proper (back) push button. ④ Lower screen to desired “down” stop position. ⑤ Set lower limit by depressing and releasing the proper (front) push button. Screw-Type Limits ① Determine which direction of travel corresponds with arrows on motor. ② Operate screen to desired “down” stop position. Set limit by turning the proper socket toward the “+” to lower the limit, and “-” to raise it. ③ Operate screen to desired “up” stopping position. Set limit by turning the proper screw toward the “-” to raise the limit, and “+” to lower it. Please Note: Screen limits are factory set for optimum performance of the screen. A procedure is outlined below for minor tweaks, but any ad- justment of these limits may negatively affect the fl atness of the screen surface and could also void the warranty. Please check with Draper prior to resetting screen limits. CAUTION: Always be prepared to shut screen off manually when new adjustment is being tested. Screen may be severely damaged if viewing surface is allowed to run too far up or too far down. CAUTION: Be sure all switches are in “off” position before ad just ing limit switches. Total width = Viewing Surface width + 35/16" 4" ½" 5" 121/32" Back Top 1½" 7/8" 213/16" 113/16" 5/8" Nocturne Exterior Projection Screen—Crank and Motorized Dimensions Motor End 1 2 + + Motor End

Page 3 of 4

Nocturne Exterior Projection Screen by Draper www.draperinc.com (765) 987-7999 Wiring Diagrams Do not wire motorized units in parallel without written consent from Draper. Wiring Diagrams Standard Motor) Single Station Control Internal Screen Wiring White (Common) Black (Down) Red (Up) Green/Yellow (Ground) Dashed wiring by electrician Control switch Single gang box by others Min. 4" x 2 1/8" x 1 7/8" deep Blue Black Red Location of key operated on-off switch if furnished To 110-120V Line Multiple Station Control Internal Screen Wiring White (Common) Black (Down) Red (Up) Green/Yellow (Ground) Dashed wiring by electrician Red Red Black Blue Blue Cap off with wire nut and tape Black Red Blue Black Single gang box by others Min. 4" x 2 1/8" x 1 7/8" deep. 3 shown. More or less equally feasible. Location of key operated on-off switch if furnished To 110-120V Line External Two-Way Serial Communication (RS232) with MC1 3 Button Wall Switch DOWN - Black COM - White UP - Red White-Common to screen & 110-120V AC Neutral Red-to screen (directional) Brown-to screen (directional) Yellow-to 110-120V AC-Hot Black-to 110-120V AC-Hot Green-Ground Eye Port for IR Eye, RF Receiver or LED Wall Switch. For more than one of these, a splitter is required. Aux Port for connecting additional LVC-III modules (up to six total can be linked- connect from Aux to Eye). Dashed wiring by electrician Low voltage wiring by others White (Common) Red (Up) Black (Down) Green (Ground) Location of key operated on-off switch if furnished To 110-120V Line Internal Screen Wiring STOP Control Switches 24v DC STOP RS232 Data FROM Control System RS232 Data TO Control System Signal Ground & Manual Switch Common Manual Switch Down Manual Switch Up White-Common to screen & 110-120V AC Neutral Red-to Screen (directional) Brown-to Screen (directional) Black-Hot to 110-120V AC Green/Yellow-Ground Fuse Program LED Eye Port for IR Eye. For RF Receiver or LED Wall Switch, a Splitter and a Power Supply is required. Plug RF Receiver or LED Wall Switch and Power Supply into splitter, then run cable from Splitter to MC1 Eye Port. Low Voltage Wiring by others AC Wiring by electrician MC1 White (Common) Red (Up) Black (Down) Green/Yellow (Gnd) Internal Screen Wiring Location of key operated on-off switch if furnished To 110-120V Line STOP Control Switches 24v DC STOP External Low Voltage and Remote Control Please Note: Do not wire motors in parallel. Internal Screen Wiring White (Neutral) Black Green (Ground) Dashed wiring by electrician To 110-120V Line Wall Switch or RF Receiver Radio Technology 110-120V Motor CAUTION: Wall switches provided with these screens are interior switches, and should not be installed outdoors.

➁ You will then need to fi nd the programming button which is a small

button on the back or side of the transmitter. You will need to de- press the button for 10-15 seconds. The motor should jog up and down once then pause and jog a second time during this time period. Once the motor has completed its second jog, then you can start at step 1 of initial programming as the motor is clear. Add/Delete a Channel/Transmitter Add: ➀ Select the channel/transmitter that is currently operating the motor, then press the programming button until the motor jogs. ➁ Select the new channel/transmitter that you want to add to the motor, then press the programming button until the motor jogs. ➂ The motor should now work on both the old and new channel/ transmitter. Delete: ➀ Select the channel/transmitter that is currently operating the motor and you want to keep, then press and hold the programming button until the motor jogs. ➁ Select the channel/transmitter that you want to remove, then press and hold the programming button until the motor jogs. ➂ The motor should now only work on the channel/transmitter from step 1. Adjust Limits in User Mode If your initial limits have changed or you want to fi ne tune a motor, you do not need to reset the motor and re-program it. You can just change the limits with these steps. ➀ Move the motor to the limit (upper or lower) that you want to change. ➁ Press and hold the UP and DOWN buttons until the motor jogs. ➂ Move the motor to its new limit location. ➃ Press and hold the STOP button until the shade jogs. Nocturne Exterior Projection Screen by Draper Page 4 of 4 www.draperinc.com (765) 987-7999 Channel se- lector button on Multi- Channel Transmitter RTS Motor/Remote Programming Instructions If you receive a Nocturne with an optional RTS motor from Draper, Inc., the motor has no programming on it, so it must be learned and programmed to work on the transmitter that you have. The limits must also be set. Here are the initial programming instructions. ➀ Connect power to motor. Select the transmitter/channel to which you plan to learn the motor. Press and hold the UP and DOWN buttons at the same time until the motor jogs, then release. ➁ Check the motor run direction by press either the UP or DOWN buttons. This is important because if you do step 3 without doing this step, then you will need to reset the motor. If you need to reverse the motor direction, then press the STOP button (middle button which might be labeled MY) for 5 seconds until the motor jogs. Check the direction again to make sure that it works. ➂ Move the motor to its upper limit position. Press the STOP and DOWN buttons at the same time until the motor starts to move down, then release. You will stop the motor at its lower limit. You can use the UP and DOWN buttons to adjust the motor to the correct lower limit position if need be. ➃ Once the motor is at its lower limit position, then press the UP and STOP buttons at the same time until the motor starts to move up, then release. The motor should move to the upper limit position in step 3 and stop. ➄ Once the motor has stopped at its upper limit position, then press and hold the STOP button for 5 seconds until the motor jogs. ➅ Now, you must put the motor into USER mode. Find the program- ming button which is a small button on the back or side of the trans- mitter and press it until the motor jogs. Once you have done this, then the motor will operate in normal fashion. ➆ Disconnect power to this motor and move to the next in your installation and start with step 1. Reconnect motor to power when all motors are programmed. Reset Motor Instructions If the motor is not working or responding correctly and you want to reprogram it from the beginning and clear all previous programming, then follow these steps. ➀ Disconnect the motor from power for 2-5 seconds, reconnect to power for 10-13 seconds, disconnect from power for 2-5 seconds, and reconnect to power. The motor should move down a little after you reconnect to power the last time.

Other Projection Screen Manuals