ABB M22344-W Manual 

Specifications

Brand: ABB
Category: Intercom System
Model: M22344-W (Manual )
File Type: PDF
File Size: —
Pages: 32

Read Online

Read the ABB M22344-W Manual  online using the built-in PDF viewer.

Text of the manual

VER:1.0 │ │ 31/12/2015

ABB-Welcome Pos: 2 /Di nA4 - Anleitung en Online/Inhalt/KN X/D oorEntr y/83220- AP- xxx/Titelbl att - 83220-AP- xxx - ABB @ 19\mod_1323249806476_15.docx @ 111084 @ @ 1 M22344-W Basic 4.3" Video hands-free indoor station === Ende der Liste für Textmar ke Cover ===

— 2 —

Pos: 4 /Busch-Jaeger (Neustruktur)/M odul-Str uktur/Online-Dokumentation/Inhal tsverzeichnis (--> Für alle D okumente <--)/Inhaltsverzeichnis @ 19\mod_1320649044386_15.docx @ 109653 @ @ 1 1 Safety ............................................................................................................ 3 2 Intended use .................................................................................................. 3 3 Environment .................................................................................................. 3 3.1 ABB devices ................................................................................. 3 4 Operations ..................................................................................................... 5 4.1 Standard operations ..................................................................... 5 4.1.1 Control elements .......................................................................... 5 4.2 Control actions .............................................................................. 7 4.2.1 Incoming call / In a call ................................................................. 7 4.2.2 Display & volume settings during calling....................................... 8 4.2.3 Communication menu ................................................................... 9 4.3 Settings ....................................................................................... 11 4.3.1 Overview ..................................................................................... 11 4.3.2 Switch actuator settings .............................................................. 12 4.3.3 Program button settings .............................................................. 13 4.3.4 Ringtone settings ........................................................................ 14 4.3.5 Volume settings .......................................................................... 15 4.3.6 Date and time settings ................................................................ 16 4.3.7 Other settings ............................................................................. 17 4.3.8 History review ............................................................................. 18 4.3.9 Language settings ...................................................................... 20 4.3.10 Information .................................................................................. 21 4.3.11 Reseting factory default .............................................................. 22 4.4 Cleaning ..................................................................................... 23 4.5 Adjusting the device.................................................................... 24 5 Technical data ............................................................................................. 25 6 Mounting / Installation .................................................................................. 26 6.1 Requirements for the electrician ................................................. 26 6.2 General installation instructions .................................................. 27 6.3 Mounting ..................................................................................... 28

Pos: 6 /Busch-Jaeger (Neustruktur)/M odul-Str uktur/Online-Dokumentation/Ü berschriften (--> Für alle Dokumente <--)/1. Ebene/S - T/Sicherheit @ 18\mod_1302612791790_15.docx @ 103357 @ 1 @ 1

1 Safety Pos: 7 /Busch-Jaeger (Neustruktur)/M odul-Str uktur/Online-Dokumentation/Sicherheit (--> Für all e D okumente <--)/Warnhi nweise/Sicherheit - 230 V @ 18\mod_1302606816750_15.docx @ 103308 @ @ 1 Warning Electric voltage! Risk of death and fire due to electrical voltage of 100-240 V. – Work on the 100-240V supply system may only be performed by authorised electricians! – Disconnect the mains power supply prior to installation and/or disassembly! Pos: 8 /Busch-Jaeger (Neustruktur)/M odul-Str uktur/Online-Dokumentation/Ü berschriften (--> Für alle Dokumente <--)/1. Ebene/A - F/Besti mmungsgemäßer Gebrauch @ 18\mod_1302763321316_15.docx @ 103483 @ 1 @ 1 2 Intended use Pos: 9 /Di nA4 - Anleitung en Online/Inhalt/KN X/D oorEntr y/83220- AP- xxx/Besti mmungsg emaesser Gebrauch - 83220-AP- xxx- 500 @ 20\mod_1324561168699_15.docx @ 112728 @ @ 1 The M22344-W is an integral part of the ABB-Welcome door communication system and operates exclusively with components from this system. The device must only be installed in dry indoor rooms. Pos: 10 /Busch-Jaeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Überschriften (--> Für alle D okumente <--)/1. Ebene/U - Z/U mwelt @ 18\mod_1302614158967_15.docx @ 103383 @ 1 @ 1 3 Environment Pos: 11 /Busch-Jaeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/U mwel t (--> Für alle D okumente <--)/Hinweise/Hi nweis - U mwelt - Hinweis Elektrog eräte @ 18\mod_1302763973434_15.docx @ 103500 @ @ 1 Consider the protection of the environment! Used electric and electronic devices must not be disposed of with domestic waste. – The device contains valuable raw materials which can be recycled. Therefore, dispose of the device at the appropriate collecting depot. Pos: 12 /DinA4 - Anl eitungen Onli ne/Ueberschriften/2./ABB Geraete @ 19\mod_1323162843832_15.docx @ 110875 @ 2 @ 1 3.1 ABB devices Pos: 13 /Busch-Jaeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/U mwel t (--> Für alle D okumente <--)/Hinweise/Hi nweis - U mwelt - ABB El ektr ogeräte @ 19\mod_1323162745839_15.docx @ 110867 @ @ 1 All packaging materials and devices from ABB bear the markings and test seals for proper disposal. Always dispose of the packaging material and electric devices and their components via the authorized collecting depots and disposal companies. ABB products meet the legal requirements, in particular the laws governing electronic and electrical devices and the REACH ordinance.

(EU-Directive 2002/96/EG WEEE and 2002/95/EG RoHS)

(EU-REACH ordinance and law for the implementation of the ordinance (EG) No.1907/2006)

Pos: 18 /DinA4 - Anl eitungen Onli ne/Ueberschriften/1./Bedi enung @ 18\mod_1302613924165_15.docx @ 103365 @ 1 @ 1

4 Operations Pos: 19 /DinA4 - Anl eitungen Onli ne/Ueberschriften/2./Nor maler Betrieb @ 18\mod_1302768820965_15.docx @ 103540 @ 2 @ 1 4.1 Standard operations Pos: 20 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Bedi enel emente @ 20\mod_1323260220559_15.docx @ 111647 @ 3 @ 1 4.1.1 Control elements Pos: 21 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/83220-AP- xxx/Bedi enelemente - 83220- AP- xxx @ 18\mod_1303212853605_15.docx @ 103673 @ @ 1 Fig. 1 Control elements 1 3 4 5 6 7 2

4.3" Color display

2 Comunication button 2A When a call is coming, press this button to activate the communication within 30 seconds and press it again to end the call. 2B In standby mode, press this button to enter the communication menu. If the LED flashes slowly, this means an incoming call. If the LED illuminates,, this means that a conversation is in progress. If the LED flashes rapidly, it means system is busy. 3 Unlock button Press this button to open the door at any time. 4 Surveillance button 4A In standby mode, press this button to survey the default outdoor station. 4B While the display is on, press this button to the survey the next outdoor station. (This function is available depending on the installation type) 4C While the display is on, hold this button to take a snapshot. 4D In standby mode, if the LED flashes, press this button to display the "History" record. If the LED flashes slowly, this represents a notification on a missed call. 5 Mute button 5A In standby mode, press this button to mute ringtone of the indoor station. 5B In standby mode, hold the button to mute ringtone of all indoor stations in the apartment. 5C When a call is coming, press this button to reject the call. 5D During the conversation, press this button to mute microphone. The LED illuminates to indicate mute status. 6 Programmable button 1 6A Release the 2nd lock connected with an outdoor station (default function). 6B *Programmable button for additional functions, e.g. call to guard unit 7 System setting button Enter the system setting menu for various functions of the device. If the LED flashes rapidly, it means that setting is busy. * For use of those buttons, please contact your electrical installer. Pos: 22 /Busch-Jaeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Steuermodul e - Onli ne-D okumentation (--> Für all e D okumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1

Pos: 26 /DinA4 - Anl eitungen Onli ne/Ueberschriften/2./Bedi enaktionen @ 20\mod_1323262294281_15.docx @ 111911 @ 2 @ 1

4.2 Control actions Pos: 27 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Sprech- und Videover bindung @ 20\mod_1323262368700_15.docx @ 111927 @ 3 @ 1 4.2.1 Incoming call / In a call Pos: 28 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/83220-AP- xxx/Sprech- und Videover bindung - 83220- AP- xxx @ 20\mod_1323262341852_15.docx @ 111919 @ @ 1 Fig. 2 Incoming call / in a call During calls, the following functions are available: No. Functions 1 Press this button to accept the incoming call; In a call, press this button to end the call. 2 Press this button to open the door where the call is from. 3-A Press this button to survey the analog camera of the outdoor station if there is one. 3-B Hold this button to take a snapshot. 4 Press this button to mute the ringtone of an incoming call; in a call, press this button to mute the microphone. 5-A Press this button to activate the function of the programmable button. 5-B If the function "release 2nd-lock" or "control switch actuator" is assigned to The programmable button, press this button to activate the function. 6-A 6-B Press this button to enable or disable the full-screen function. Hold this button to enter the brightness and volume setttings menu. 7 Time left of the connection. 8 Number of outdoor stations Pos: 29 /Busch-Jaeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Steuermodul e - Onli ne-D okumentation (--> Für all e D okumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1 30s Outdoor 1 1 3 6 7 8 2 4 5

Pos: 30 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Tuer oeffnen @ 20\mod_1323263277453_15.docx @ 111935 @ 3 @ 1

4.2.2 Display & volume settings during calling Pos: 31 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/83220-AP- xxx/Tuer oeffnen - 83220- AP- xxx @ 20\mod_1323267958479_15.docx @ 112109 @ @ 1 Fig. 3 Display & volume settings during calling Hold button for 3s to enter the display & volume setttings menu during a call or conversation, the following functions are available. No. Functions 1 Navigation buttons ( up / down / confirm / cancel, etc) 2 Press the navigation buttons as needed. 3 Speech volume(only can be adjusted during conversation) 4 Saturation 5 Brightness 6 Value set Pos: 32 /Busch-Jaeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Steuermodul e - Onli ne-D okumentation (--> Für all e D okumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1 120s Outdoor 1 2 4 5 6 1 2 3

Pos: 33 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Stumm schalten @ 20\mod_1323263607142_15.docx @ 111951 @ 3 @ 1

Pos: 66 /Busch-Jaeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Steuermodul e - Onli ne-D okumentation (--> Für all e D okumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1 4.2.3 Communication menu Pos: 31 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/83220-AP- xxx/Tuer oeffnen - 83220- AP- xxx @ 20\mod_1323267958479_15.docx @ 112109 @ @ 1 4.2.3.1 Overview Press button to enter the communication menu. The following functions are available: No. Functions 1 Call to guard unit -Call guard unit directly. 2 Swtich actuator -Activate the existing actuator list

Set the actuator list in the “system settings-switch actuator“ menu first.

After chosing a list, press button √ to enable the lock or light which is connected with the switch actuator. SWITCH ACTUATOR Actuator 1 (001)

to enter the system settings menu. The following functions are available:

No. Functions 1 Switch actuator -Set the actuator list in this menu 2 Program button -Set functions for programmable buttons 3 Ringtone -Set the ringtone for outdoor bells, indoor bell or others 4 Volume -Set ringtone volumes 5 Date and time -Set different times. 6 Other settings -Other settings, e.g. auto full screen 7 History -View all communication entries in the menu, e.g. received calls, missed calls, 8 Language -Set the local language 9 Information 10 Reset factory default Pos: 27 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Sprech- und Videover bindung @ 20\mod_1323262368700_15.docx @ 111927 @ 3 @ 1

Switch actuator settings

Fig. 5: Switch actuator settings No. Functions 1 Existing switch actuator list: Press button √ to modify the settings. 2 Add a new actuator list:Totally, up to 10 switch actuator lists can be added. 3 Enter to change target address with “+” or “-” button from 001 to 199. 4 Rename the switch actuator list: Scroll through letters of the alphabet or numbers one by one with “+” or “-” button 3 4 SWITCH ACTUATOR Actuator 1 (001) Add New Target Address Rename 002 light Save Cancel SWITCH ACTUATOR 2 1 Add a new list

Program button settings

Fig. 6: Program button settings No. Functions 1 Set functions for the program button, e.g. releasing 2nd-lock, calling guard unit, enabling the switch actuator. *Only the switch actuator list can be assigned to the program button. Button 1 Release 2nd-Lock PROGRAM BUTTON 1

Select the bell sound for the default outdoor station.

2 Select the bell sound for other outdoor stations. 3 Select the bell sound for the apartment door. 4 Select the bell sound for others, e.g.a call from the guard unit 1 Default Outdoor Other Outdoors RING TONE Ring Tone 1 Ring Tone 2 2 Doorbell Ring Tone 3 Others Ring Tone 4 3 4

Set the volume of bell sound.

2 Enable/disable the feedback tone which sounds when the touch button is pressed. 3 The ringtone can be set fixed or cycled. 1 Ringtone Volume Touchbutton Tone VOLUME Volume 3 2 √ Repeated Tone √ 3

Date and time settings

Fig. 9: Date and time settings No. Functions 1 Set the date. 2 Set the time. 3 Enable/disable the summer time function. 1 Date(YYYY-MM-DD) Time DATE AND TIME 2013 2 08 Summer Time √ : 00 - 01 - 01 3

Fig. 10: Other settings

No. Functions 1 Enable/disable the auto full screen function. 2 Enable/disable the auto-snapshot function. 3 Enable/disable the missed call function( flashes when there is a missed call). 1 Auto Full Screen Auto-snapshots OTHER SETTINGS √ 2 Missed Call √ √ 3

Fig. 11: History review

No. Functions 1 Up to 100 events can be recorded in the history menu. -If the snapshot function is enabled, an icon is diplayed.If no snapshot function, the icon is not displayed.. -Date, time and type of the event are recorded together with the snapshot. - Directions: means dialing calls means receiving calls means missed calls ● HISTORY 1/2 Outdoor -1 1/63 2013-03-21 16:45 Outdoor - 1 ● 2013-03-21 16:45 Outdoor - 1 ● 2013-03-21 14:24 Outdoor - 1 1 2 3

Press this button to view details of this event.

Two pictures are always made when a visitor rings the bell. 3 Press this button to delete a record item

Fig. 13: Information of the indoor station (scanning the QR code to get the detailed

instruction of the indoor station) Flash Version: V1.02_151210_US INFORMATION MCU Version: V1.02_151210_US M/S: Master Default Outdoor: 1 Indoor St. Add.: 001

Reseting factory default

Fig. 14: Reseting factory default No. Functions 1 Reset all settings: Reset the device and restore all default configurations. The operation does not delete the programmed data and history, such as switch actuator lists. 2 Clear all data: Delete all programmed data and history. Also all configurations will be restored to factory default settings. Are you sure to reset? RESET FACTORY DEFAULT Cancel OK Reset All Settings Clear All Data × √

Pos: 67 /DinA4 - Anl eitungen Onli ne/Ueberschriften/2./Rei nigung @ 19\mod_1310733980533_15.docx @ 107853 @ 2 @ 1

4.4 Cleaning Pos: 68 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/Rei nigung/Rei nigung Touchscreenmonitor @ 19\mod_1310734108978_15.docx @ 107862 @ @ 1 Caution Risk of damage to the screen surface. The screen surface can be damaged by hard or sharp objects! Never use such objects for entries on the touch screen monitor. – Use your finger or a plastic stylus. The screen surface can be damaged by cleaning fluids or abrasive agents! – Clean the surfaces using a soft cloth and commercially available glass cleaner. – Never use abrasive cleaning agents. Pos: 69 /Busch-Jaeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Steuermodul e - Onli ne-D okumentation (--> Für all e D okumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1

Pos: 70 /DinA4 - Anl eitungen Onli ne/Ueberschriften/2./Geraeteei nstellungen @ 18\mod_1302768847744_15.docx @ 103548 @ 2 @ 1

4.5 Adjusting the device Pos: 71 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Abschlusswiderstand @ 19\mod_1321958079906_15.docx @ 110083 @ 3 @ 1 Pos: 72 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/Bedienung/Abschl usswiderstand setzen 83220-AP- xxx @ 19\mod_1310723392369_15.docx @ 107841 @ @ 1 Fig. 15: Pos: 74 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/Bedienung/Master/Sl ave Schalter setzen 83220-AP- xxx @ 19\mod_1310723320966_15.docx @ 107833 @ @ 1. Station Selector switch to set the address of default outdoor station. 2. X10 X1 Selector switches to set the address (tens and units digits) of the indoor station. X200 X100 Dip-switches to set the address (hundreds digits) of the indoor station. 3. Master /Slave function Only one indoor station in each apartment must be set as "Master" (Switch should be set as 'M/S on'). All additional indoor stations in the same apartment must be set as "Slave" (Switch should be set as 'M/S off'). 4. Terminal resistor In video installations or mixed audio and video installations, the Switch must be set as 'RC on' on the last device of the line. 5. a b = Bus connection = Door bell connection DC GND = Additional power supply 6. Connector for induction loop Pos: 75 /Busch-Jaeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Steuermodul e - Onli ne-D okumentation (--> Für all e D okumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1

Pos: 76 /DinA4 - Anl eitungen Onli ne/Ueberschriften/1./Technische D aten @ 18\mod_1302615863001_15.docx @ 103416 @ 1 @ 1

5 Technical data Pos: 77 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/83220-AP- xxx/Technische D aten - 83220-AP- xxx @ 18\mod_1303212854559_15.docx @ 103705 @ @ 1 Designation Value Display resolution: 480 x 272 Display size: 4.3” Operating temperature -10° C - +55° C Storage temperature -40° C – +70° C Protection IP 30 Single-wire clamps 2 x 0.28 mm² – 2 x 0.75 mm² Fine-wire clamps 2 x 0.28 mm² – 2 x 0.75 mm² Bus voltage 20-30 V Size 137 x 155 x 24 mm Pos: 78 /Busch-Jaeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Steuermodul e - Onli ne-D okumentation (--> Für all e D okumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1

Pos: 79 /Busch-Jaeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Überschriften (--> Für alle D okumente <--)/1. Ebene/M - O/Montage / Installation @ 18\mod_1302613966111_15.docx @ 103373 @ 1 @ 1

6 Mounting / Installation Pos: 80 /Busch-Jaeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Sicherheit (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - Ni ederspannungs- und 230 V-Leitungen @ 18\mod_1302617821491_15.docx @ 103465 @ @ 1 Warning Electric voltage! Risk of death and fire due to electrical voltage of 100-240 V. – Low-voltage and 100-240 V cables must not be installed together in a flush-mounted socket! In case of a short-circuit there is the danger of a 100-240 V load on the low-voltage line. Pos: 81 /Busch-Jaeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Sicherheit (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - Fachkenntnisse @ 18\mod_1302774384017_15.docx @ 103564 @ 2 @ 1 6.1 Requirements for the electrician Warning Electric voltage! Install the device only if you have the necessary electrical engineering knowledge and experience. • Incorrect installation endangers your life and that of the user of the electrical system. • Incorrect installation can cause serious damage to property, e.g. due to fire. The minimum necessary expert knowledge and requirements for the installation are as follows: • Apply the "five safety rules" (DIN VDE 0105, EN 50110): 1. Disconnect from power; 2. Secure against being re-connected; 3. Ensure there is no voltage; 4. Connect to earth; 5. Cover or barricade adjacent live parts. • Use suitable personal protective clothing. • Use only suitable tools and measuring devices. • Check the type supply network (TN system, IT system, TT system) to secure the following power supply conditions (classic connection to ground, protective earthing, necessary additional measures, etc.). Pos: 82 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/Montage/M ontagehinweise - Allgemein @ 19\mod_1310563670478_15.docx @ 107743 @ 2 @ 1

General installation instructions

• Terminate all branches of the wiring system via a connected bus device (e.g., indoor station, outdoor station, system device). • Do not install the system controller directly next to the bell transformer and other power supplies (to avoid interference). • Do not install the wires of the system bus together with 100-240 V wires. • Do not use common cables for the connecting wires of the door openers and wires of the system bus. • Avoid bridges between different cable types. • Use only two wires for the system bus in a four-core or multi-core cable. • When looping, never install the incoming and outgoing bus inside the same cable. • Never install the internal and external bus inside the same cable. Pos: 83 /Busch-Jaeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Steuermodul e - Onli ne-D okumentation (--> Für all e D okumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1

Pos: 84 /Busch-Jaeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Überschriften (--> Für alle D okumente <--)/2. Ebene/M - O/Montage @ 18\mod_1302615960458_15.docx @ 103424 @ 2 @ 1

6.3 Mounting Recommended installation height Dismantling Open the housing of the panel by pulling the clamp at the bottom of the device.

The bottom of the device has screw holes for fastening on the wall according to the

above dimension instructions. 2. In addition, the bottom of the device can be fixed to the existing flush-mounted box. The dimension of the compatible flush-mounted box is shown in graphics above. Wiring Fix the bottom of the device and connect it in accordance with the graphics. The insulated section of the cable end must not be longer than 10mm.

Set addresses of the preferred outdoor stations and the address of the indoor station on

the jumper (see chapter " Adjusting the device "). Three types of installation: A. Surface-mounted 1) Mounted on the wall 1. Fix the bottom of the device to the wall. 2. Latch the upper part of the device onto its bottom part: place the upper side of the device on the lock-in lugs and then press the bottom side onto the bottom part of the device until it is caught by the clamp. 2) Mounted with flush-mounted box 1. Fix the bottom of the device to the existing flush-mounted box. 2. Latch the upper part of the device onto its bottom part: place the upper side of the device on the lock-in lugs and then press the bottom side onto the bottom part of the device until it is caught by the clamp.

Mounted with desktop bracket

1. Fix the bottom of the device to the desktop bracket. 2. Latch the upper part of the device onto its bottom part: place the upper side of the device on the lock-in lugs and then press the bottom side onto the bottom part of the device until it is caught by the clamp. : 94 /Busch-Jaeger (N eustruktur)/M odul-Struktur/Onli ne-D okumentation/Steuer module - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1

Pos: 95 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/Pr ojektier ung-Mer kblatt/Proj ekti erPos: 97 /Busch-Jaeger (Neustruktur)/M odul-Str uktur/Online-Dokumentation/R ückseiten (--> Für alle D okumente <--)/Rückseite - Busch-Jaeger - Allgemein @ 20\mod_1327320074886_15.docx @ 137103 @ @ 1

Notice === Ende der Liste für Textmar ke Backcover === We reserve the right to at all times make technical changes as well as changes in the contents of this document without prior notice. The detailed specifications agreed to at the time of ordering apply to all orders. ABB accepts no responsibility for possible errors or incompleteness in this document. We reserve all rights to this document and the topics and illustrations contained therein. The document and its contents, or extracts thereof, must not be reproduced, transmitted or reused by third parties without prior written consent by ABB. Pos: 85.1 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/DoorEntr y/83220-AP- xxx/M ontag e - M odul e/Montage - Montagedose -- 83220-AP- xxx @ 19\mod_1323250406848_15.docx @ 111098 @ @ 1

Other Intercom System Manuals