NEC NEAX 2000 IVS Command Manual

Text of the manual

NEC America, Inc. reserves the right to change the specifications,

functions, or features, at any time, without notice. NEC America, Inc. has prepared this document for use by its em- ployees and customers. The information contained herein is the property of NEC America, Inc. and shall not be reproduced without prior written approval from NEC America, Inc. NEAX and Dterm are registered trademarks of NEC Corporation. Copyright 1997 NEC America, Inc. Printed in USA

Addendum Revision Sheet 1/7

ND-45669 (E) ISSUE 2 PAGE No. ADD. No. 001 002 003 004 005 006 007 008 i 2.2 ii iii 2.1 iv 2.1 v vi 1 2 3 4 5 6 7 8 9 10 11 12 13 2.1 14 15 16 17 18 19 20 2.2 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 2.1 44-1 2.1 44-2 2.1 45 2.2 46 47 48 49 50 2.1 2.2 51 52 53 54 55 56 57 58 2.1 59 60 61 62 2.2 63 64 65 66 2.1 67 2.1 68 2.1 PAGE No. ADD. No. 001 002 003 004 005 006 007 008

Addendum Revision Sheet 2/7

ND-45669 (E) ISSUE 2 69 70 2.1 2.2 70-1 2.2 70-2 2.2 71 72 73 74 2.1 74-1 2.1 74-2 2.1 75 76 77 2.2 77-1 2.2 77-2 2.2 78 2.2 79 2.1 80 81 82 83 2.1 84 2.1 85 86 87 88 2.1 89 90 2.1 91 92 93 94 95 96 2.1 97 98 99 100 PAGE No. ADD. No. 001 002 003 004 005 006 007 008 101 2.2 102 2.2 103 104 105 2.1 106 2.1 107 108 109 110 2.1 2.2 110-1 2.1 2.2 110-2 2.1 111 112 113 114 115 116 117 118 119 120 121 2.1 122 123 124 125 126 2.2 127 128 2.1 129 2.1 130 2.2 131 132 133 134 135 136 PAGE No. ADD. No. 001 002 003 004 005 006 007 008

Addendum Revision Sheet 3/7

ND-45669 (E) ISSUE 2 137 138 139 140 2.1 2.2 140-1 2.1 2.2 140-2 2.1 141 142 143 144 145 146 147 148 149 150 151 152 153 2.1 154 155 2.1 156 2.2 156-1 2.2 156-2 2.2 157 158 159 160 2.1 2.2 161 162 163 164 165 166 167 168 169 170 PAGE No. ADD. No. 001 002 003 004 005 006 007 008 171 172 2.1 173 2.1 174 2.1 174-1 2.1 174-2 2.1 175 176 177 178 179 180 181 182 183 184 2.2 185 186 187 188 188-1 2.1 188-2 2.1 189 190 191 2.1 192 193 2.1 194 195 196 197 198 199 2.1 199-1 2.1 199-2 2.1 200 2.1 2.2 201 202 PAGE No. ADD. No. 001 002 003 004 005 006 007 008

Addendum Revision Sheet 4/7

ND-45669 (E) ISSUE 2 203 2.2 204 205 2.1 206 2.2 207 2.2 208 209 210 2.2 211 212 213 2.2 214 215 2.1 216 2.1 2.2 216-1 2.1 216-2 2.1 217 2.1 218 2.1 219 220 221 2.1 222 223 224 225 226 227 228 229 230 231 232 233 2.2 234 2.2 235 236 2.1 237 2.1 2.2 238 PAGE No. ADD. No. 001 002 003 004 005 006 007 008 239 2.1 240 241 242 243 244 245 246 247 2.2 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 2.1 264 2.1 265 266 2.1 267 268 269 270 271 272 273 274 275 276 2.2 PAGE No. ADD. No. 001 002 003 004 005 006 007 008

Addendum Revision Sheet 5/7

ND-45669 (E) ISSUE 2 277 2.2 278 279 280 281 282 283 284 285 286 287 2.1 2.2 288 2.1 289 2.1 290 2.1 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 2.2 311 2.2 311-1 2.2 311-2 2.2 312 PAGE No. ADD. No. 001 002 003 004 005 006 007 008 313 314 315 316 317 318 319 320 321 322 323 324 2.1 325 326 2.1 327 2.1 327-1 2.1 327-2 2.1 2.2 327-3 2.1 327-4 2.1 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 PAGE No. ADD. No. 001 002 003 004 005 006 007 008

Addendum Revision Sheet 6/7

ND-45669 (E) ISSUE 2 347 348 2.2 349 2.2 350 351 352 353 2.2 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 2.1 371 2.1 372 373 374 375 376 377 378 379 380 381 382 383 384 PAGE No. ADD. No. 001 002 003 004 005 006 007 008 385 386 387 388 389 390 391 392 393 394 395 2.1 396 397 398 2.2 399 2.2 400 401 402 403 404 405 406 407 408 409 410 411 412 2.2 413 414 2.2 415 416 417 418 419 420 421 422 PAGE No. ADD. No. 001 002 003 004 005 006 007 008

Addendum Revision Sheet 7/7

ND-45669 (E) ISSUE 2 423 424 425 426 427 428 429 430 PAGE No. ADD. No. 001 002 003 004 005 006 007 008 PAGE No. ADD. No. 001 002 003 004 005 006 007 008

TABLE OF CONTENTS

Addendum-002 Page i JANUARY, 1999 Revision 2.2 ND-45669 (E) ISSUE 2 DECEMBER, 1997 NEAX2000 IVS Command Manual TABLE OF CONTENTS Page LIST OF FIGURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v LIST OF TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi CHAPTER 1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1. PURPOSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. OUTLINE OF THE MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 CHAPTER 2 INFORMATION FOR DATA PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1. GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2. DESCRIPTION OF CAT AND MAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.1 How to Use the CAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.1.1 CAT Key Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.1.2 CAT Mode Setting Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2.1.3 Notice on the CAT Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2.2 CAT Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.3 Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 3. COMMAND REFERENCE TABLE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 3.1 List of Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 3.2 Quick Reference Table of Commands Required for Service Feature . . . . . . . . . . . . . . . . . . . . 14 4. PRECAUTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 4.1 Conditions for Using Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 4.2 Method of Setting On-Line/Off-Line Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 4.3 Method for Installing Line/Trunk Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 4.4 Password Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 CHAPTER 3 DESCRIPTION OF COMMANDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 1. GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 2. DETAILED DESCRIPTION OF COMMANDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 [CM00] System Data Memory All Clear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 [CM01] System Data Memory Partial Clear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 [CM02] Setting of System Clock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 [CM03] Log In/Log Out of Password Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 [CM04] Language Indicated on Multiline Terminal LCD. . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 [CM05] Card Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 [CM06] Misc. Trunk Number Assignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 [CM07] DTI Trunk/ISDN Trunk Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 [CM08] Basic Service Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 [CM09] Additional Service Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 [CM10] Station Number, Trunk Number, Card Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 [CM11] Virtual-Line Number. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96

TABLE OF CONTENTS

ND-45669 (E) Page ii Revision 2.0 TABLE OF CONTENTS (CONTINUED) Page [CM12] Station Class-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 [CM13] Station Class-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 [CM15] Service Restriction Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 [CM16] Call Pickup Group/Group Diversion Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 [CM17] UCD Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 [CM18] Station Hunting Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 [CM19] Secretary/Group Diversion Station Number. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 [CM1A] Data Station Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 [CM1B] ISDN Terminal Multipoints Station Number Assignment . . . . . . . . . . . . . . . . . . . . . 126 [CM1C] PS Station Number Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 [CM1D] PS-ID Assignment/PS Operation Data Download . . . . . . . . . . . . . . . . . . . . . . . . . . 128 [CM20] Numbering Plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 [CM21] Single Digit Access Code. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 [CM22] Route Advance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 [CM23] Tenant Development . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 [CM24] Kind of Calling Terminal Development. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 [CM25] Kind of Special Terminal Development . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146 [CM26] Closed Number Development . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 [CM29] Numbering Plan Tenant Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 [CM2A] ID Code Assignment with MP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 [CM30] Trunk Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 [CM31] System Attribute Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158 [CM35] Trunk Route Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 [CM36] Restriction Data for Tandem Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 [CM38] AMP Trunk. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176 [CM40] Function of RS-232C Interface Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178 [CM41] System Timer Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183 [CM42] System Counter Data/pad Data/trunk Restriction Class Conversion. . . . . . . . . . . . 197 [CM44] External Equipment Starting Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203 [CM45] Purpose of PBR/CFT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205 [CM48] Hold/wake-up/timed Reminder/automated Attendant Tone . . . . . . . . . . . . . . . . . . . 208 [CM49] Digital Announcement Trunk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212 [CM50] Common Route Indial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217 [CM51] Automatic Transfer Destinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219 [CM52] Hot Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 [CM53] Trunk Answer From Any Station Restriction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 [CM56] Intercom Zone Paging Group/Intercom Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225 [CM58] LDN Diversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 [CM59] TAS/ACD/UCD Relay Interruption Pattern. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 [CM5A] Virtual Line – Virtual Trunk Path Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 [CM60] ATT Group, Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232 [CM61] External Key Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234 [CM62] Tenants For Each Att Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235 [CM63] Restriction of Inter-Tenant Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236 [CM64] Automated Attendant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237 [CM65] Service Features on Tenant Basis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238 [CM71] Memory Allocation for System Speed Dialing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 [CM72] Stored Number for System Speed Dialing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243 [CM73] Memory Allocation for Station Speed Dialing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244

TABLE OF CONTENTS

Addendum-001 Page iii AUGUST, 1998 Revision 2.1 TABLE OF CONTENTS (CONTINUED) Page [CM74] Stored Number for Station Speed Dialing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247 [CM76] Digit Conversion on DID Call . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248 [CM77] Station/Trunk Name Asignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252 [CM78] Destination of Split Call Forwarding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254 [CM81] Toll Restriction Pattern on Each Trunk Restriction Class . . . . . . . . . . . . . . . . . . . . 255 [CM85] Maximum Digits on C.O. Calls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257 [CM88] Automatic Pause Entry Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258 [CM8A] LCR/Toll Restriction Development Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259 [CM90] Multiline Terminal/SN610 ATTCON/Add-On Module Key Assignment . . . . . . . . . . 267 [CM93] Prime Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301 [CM94] Multiline Terminal One-Touch Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302 [CM96] DSS Console Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303 [CM97] DSS Console Key Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304 [CM98] Add-On Module Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 308 [CM9A] Multiline Terminal Soft Key Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309 [CMA0] Type Of Data Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312 [CMA1] Data Terminal Attribute Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313 [CMA5] Nailed Down Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316 [CMA6] Attribute Data For RS-232C Port On AP01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317 [CMA7] CCIS Channel Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 320 [CMA8] CCIS Routing Label Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322 [CMA9] ISDN D-Channel Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323 [CMAA] DTI/DCH/CIR Card Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324 [CMAC] ISDN Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325 [CMAD] ZT Calling Area/Pad Data Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326 [CMAE] ZT Operation Data Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 327 [CMAF] Visitor PS Data Assignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 327-2 [CMB0] Peg Count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328 [CMB1] Traffic Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332 [CMB3] UCD Peg Count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334 [CMD5] ID Code Assignment With AP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 336 [CMD6] ID Code All Clear With AP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338 [CMD7] OAI Control Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 339 [CMD9] Centralized Billing Data Port Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342 [CMDB] Calling Number Development Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343 [CMDC] Calling Number Development Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346 [CME0] Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347 [CME5] Station, Trunk Line Make Busy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348 [CME6] Call Forwarding Set/Reset From MAT/CAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349 [CME7] Password Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350 [CME9] Password Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351 [CMEA] Fault Information Store/Display Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 352 [CMEC] Battery Release/Line Status Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 361 [CMEE] Virtual Tie Line Set/Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363 [CME1, F0, F1] Special Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364 [CMF2, F3] Special Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 365 [CMF5] Special Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366 [CMF8] Special Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 368 [CMD000] System Features (1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 369

TABLE OF CONTENTS

ND-45669 (E) Page iv Addendum-001 Revision 2.1 AUGUST, 1998 TABLE OF CONTENTS (CONTINUED) Page [CMD001] System Features (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372 [CMD003] Time Block Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394 [CMD004] Office Number Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 395 [CMD012] Station Group Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 396 [CMD015] Station Service Classes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397 [CMD016] Station Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 398 [CMD026] Route Index For Call Charge Development. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400 [CMD027] Call Charge Development Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 401 [CMD031] ROOM STATUS CODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402 [CMD033] Route Index For Call Development . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 404 [CMD034] Call Development Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405 [CMD035] Designation Of Printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 407 [CMD100] System Data Partial Clear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 408 [CMD101] System Data All Clear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 409 [CMD102] Additional Memory Clear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 410 CHAPTER 4 RESIDENT SYSTEM PROGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411 1. GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411 2. PROCEDURE FOR LOADING THE RESIDENT SYSTEM PROGRAM . . . . . . . . . . . . . . . . . . . . . . . 411 3. SERVICE CONDITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411 4. PROGRAMMED DATA TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412

LIST OF FIGURES

Page v Revision 2.0 LIST OF FIGURES Figure Title Page Figure 2-1 CAT Key Assignment for ETJ-16DD-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Figure 2-2 Line/Trunk Card Installation Location. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

LIST OF TABLES

ND-45669 (E) Page vi Revision 2.0 LIST OF TABLES Table Title Page Table 2-1 Function Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Table 2-2 Digit Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Table 2-3 Assignment Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Table 2-4 Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Table 2-5 List of Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Table 2-6 List of Commands for Each Business Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Table 2-7 List of Commands for Each Hotel/Motel Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Table 2-8 Commands and Their Using Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Table 2-9 Port Assignment on Each Line/Trunk Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Table 2-10 Example of Password Level Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Table 3-1 Quick Reference Data Table for SMDR (NEAX2400 IMS Format) . . . . . . . . . . . . . . . . . . . . . 386 Table 3-2 Quick Reference Data Table for SMDR (NEAX1400 IMS Format) . . . . . . . . . . . . . . . . . . . . . 387 Table 3-3 Quick Reference Data Table for Printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 388 Table 3-4 Quick Reference Data Table for PMS (IMS Format) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 389 Table 3-5 Quick Reference Data Table for VMS with MCI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390 Table 4-1 Basic Service Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412 Table 4-2 Station Number, Trunk Number, Card Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413 Table 4-3 Station Class Data: Initial Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414 Table 4-4 Numbering Plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415 Table 4-5 Trunk Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 417 Table 4-6 Trunk Route Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 419 Table 4-7 Memory Allocation for System Speed Dialing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 425 Table 4-8 Memory Allocation for Station Speed Dialing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 426 Table 4-9 Multiline Terminal Line Key Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 427 Table 4-10 Prime Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 428 Table 4-11 Memory Allocation for One-Touch Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 429

This manual provides descriptions of the commands required for programming the NEAX2000 IVS (PBX) us-

ing the Customer Administration Terminal (CAT) or Maintenance Administration Terminal (MAT). 2. OUTLINE OF THE MANUAL This manual consists of the introduction (Chapter 1) and the following chapters: • CHAPTER 2 (INFORMATION FOR DATA PROGRAMMING): This chapter provides the basics of Customer Administration Terminal (CAT) programming, a command reference table and precautions for using commands. • CHAPTER 3 (DESCRIPTION OF COMMANDS): This chapter provides a detailed description of each command. • CHAPTER 4 (RESIDENT SYSTEM PROGRAM): This chapter explains the detailed information on the default and Resident System Program data such as specification and programming data, etc.

INFORMATION FOR DATA PROGRAMMING

CHAPTER 2 INFORMATION FOR DATA PROGRAMMING 1. GENERAL This chapter provides information on the Customer Administration Terminal (CAT) and Maintenance Admin- istration Terminal (MAT) which are used as the man-machine interface with the PBX, and various tables used for indexing the commands by feature. 2. DESCRIPTION OF CAT AND MAT In the PBX, the CAT or MAT is used for programming. The CAT is a digital multi-function telephone (Multiline Terminal) which is equipped with function keys, a dial- pad and LCD (16 characters), and interfaces with the system via the MP card. The MAT is the personal computer, which interfaces with the system via the MP card. For further details, refer to the MAT Operation Guide. 2.1 How to Use the CAT 2.1.1 CAT Key Functions In the CAT mode, each key on the Multiline Terminal is automatically assigned, as shown in Figure 2-1. The function of each key is shown in Table 2-1 and Table 2-2.

INFORMATION FOR DATA PROGRAMMING

Figure 2-1 CAT Key Assignment for ETJ-16DD-1 A B C D E F & – ST EXE CE S , – ← DE 1 2 3 DE 4 5 6 – 7 8 9 EXE A 0 B ST ← , CE S G Q H R I S J T K U L V M W N X O Y P Z

INFORMATION FOR DATA PROGRAMMING

Table 2-1 Function Keys FUNCTION KEY MEANING ST Command entry start EXE Execution of data write CE Cancel of key operation (Clear entry) S Display of next data (Step forward) , Separator; to be entered between two different data such as first/second data of CM72/74/ 90/97. — Display of previous data (Step backward) ← Cancel of one character out of the entered data (Backspace) DE Data End; to be entered at the end of the command code or at the end of each data entry. Table 2-2 Digit Keys DIGIT KEY MEANING 0-9, A-F Data (Data is entered by hexadecimal code 0 - F) A *: As a dial digit B #: As a dial digit C Clear Assigned data by “CCC” G–Z Data (Data is entered as character code) used for name assignment

INFORMATION FOR DATA PROGRAMMING

2.1.2 CAT Mode Setting Procedure 2.1.3 Notice on the CAT Mode (1) CAT mode is used in on-line mode. Therefore, system data clear commands (CM00, CM01) cannot be accessed from the CAT. (2) To use the CAT after clearing all system data, perform the following operations on the system: (a) Plug a PN-2DLCB/4DLCA card into the LT00 slot of PIM0. (b) Connect the CAT (Multiline Terminal) to LEN0000 at the MDF. (c) Set SW3 on the MP card to “B”. (d) Depress SW1 on the MP card. (System Data All Clear) (e) Set SW3 on the MP card to “0”, and depress SW1. (On-Line mode) (f) Set the CAT mode on the Multiline Terminal. (3) During CAT mode, do not change or delete the following data: • CM10, My Line Number of the CAT. (4) There are no limitations on the number of Multiline Terminals in the system that can be programmed to allow CAT capability. However, the number of Multiline Terminals that can be placed into CAT mode, at the same time, is two. To set CAT mode: 1. Press 5. Press – CNF lamp flashes 2. Press 6. Press – CNF lamp flashes – CNF, SPKR, ANS lamp on 3. Press – “CAT MODE” displayed on LCD – CNF lamp off 7. Press 4. Press – “COMMAND=–” displayed on LCD Note: Steps 1 through 6 need to be completed within 4 seconds. To clear CAT mode: While “COMMAND =– is displayed on the LCD. 1. Lift handset (Off Hook) - SPKR lamp off. 2. Replace handset (On Hook) - CNF, ANS lamps off. - LCD returns to clock. TRF CNF CNF # * ST TRF

INFORMATION FOR DATA PROGRAMMING

2.2 CAT Operation When setting the office data, it is necessary to enter the following three kinds of data: • Command Code • First Data • Second Data An explanation of the data entry procedure follows: (a) Operation for confirming the existing office data With the above entry completed, the present second data is displayed on the LCD. If the second data is not assigned yet, either the initial data value or “NONE” is displayed. (b) Operation for assigning (changing) the office data With EXE pressed, "OK" is displayed on the LCD. To confirm the data assigned, depress DE after entering the first data. (c) Use of button and button • If is pressed after setting the second data (after has been pressed), the next first data is displayed. • If is pressed after setting the second data (after has been pressed), the last data is dis- played. + Command Code + + First Data + ST DE DE + Command Code + + First Data + + Second Data + + ST DE DE DE EXE S – S EXE – EXE

INFORMATION FOR DATA PROGRAMMING

(1) Example: When Station Number 300 is to be assigned to LEN 0000 and Station Number 301 to LEN 0001 by CM10 (Refer to Table 2-3.) Note 1: When no data exists, “NONE” is displayed. And when data exists, that data is displayed. Note 2: This operation is for confirming the data assignment. Thus it may be omitted. Table 2-3 Assignment Operation (DISPLAY) STEP 1 Turn ON power switch. STEP 2 Press . STEP 3 Enter “10” (Command Number). STEP 4 Press . STEP 5 Enter “0000” (LEN). STEP 6 Press . Note 1 STEP 7 Enter “300” (Station Number). STEP 8 Press . STEP 9 Press . Note 2 STEP 10 Press . Note 1 STEP 11 Enter “301” (Station Number). STEP 12 Press . STEP 13 Press . Note 2 STEP 14 Turn OFF power switch. _ ST COMMAND = _ COMMAND = 10 _ DE 10> _ 10> 0000_ DE 10> 0000: NONE-_ 10> 0000: NONE-300 EXE OK _ DE 10> 0000: 300-_ S 10> 0001: NONE__ 10> 0001: NONE-301 EXE OK _ DE 10> 001 : 301 _ DE

INFORMATION FOR DATA PROGRAMMING

(2) Example of Operating Steps for Correcting the Data Entry (3) Example of Deleting Station Number “300” assigned to LEN000 • In Step 5 in Table 2-3, when is pressed after entering “0001” by mistake, press . Then the state returns to STEP 4. STEP 1 CM10 has been entered and has been pressed. STEP 2 “0001” has been entered instead of “0000” as intended. STEP 3 “0001” has been assigned as first data after pressing . STEP 4 If is pressed, the state returns to that of Step 1. STEP 5 Enter “0000”. STEP 6 Press , and assign the correct first data. • If, in Step 11 in Table 2-3, when “302” has been entered instead of “301”, press . Then the cursor moves to the position of “2”. STEP 1 In Step 11, enter “302” instead of “301” as intended. STEP 2 Press . STEP 3 Press digit Key “1”. 0000 is to be deleted after completing all the operations in Table 2-3. STEP 1 Press . STEP 2 Enter “10” (Command Number). STEP 3 Press . STEP 4 Enter LEN “0000”. STEP 5 Press . STEP 6 Enter “CCC”. STEP 7 Press . STEP 8 Press . DE CE DE 10> _ 10> 0001_ DE 10> 0001: NONE-__ CE 10> _ 10> 0000_ DE 10> 0000: NONE__ ← 10> 0001: NONE-302 ← 10> 0001: NONE-30__ 10> 0001: NONE-301__ ST COMMAND = _ COMMAND = 10 _ DE 10> _ 10> 0000 DE 10> 0000: 300- 10> 0000: 300-CCC EXE OK DE 10> 0000: NONE

INFORMATION FOR DATA PROGRAMMING

2.3 Error Messages When an erroneous operation is performed, or wrong data is entered, an error message is displayed on the LCD. Error messages and their meanings are shown in Table 2-4. Table 2-4 Error Messages ERROR MESSAGE MEANING OF MESSAGE ACTION DIGIT ERROR Error in the number of digits entered. Press “ST” or “CE” and enter correct data. DATA ERROR The value of the entered data is incorrect. Same as above. CODE NOT USED The command code entered is not in use, or password is needed. Same as above, or follow the procedure for entering a password. DATA NOT FOUND A Station Number not assigned has been en- tered. Same as above. WAIT BUSY NOW The station or trunk, for which data is to be changed, is busy. Wait until it becomes idle. ASSIGNED ALREADY This error message is displayed when not enough digits are entered. For example, when assigning “12” for a service access code, even if “123” has already been used for an- other service access code. Press “ST” or “CE” and enter correct data. HARDWARE ERROR Memory read/write disabled. Check switch setting of MP card or replace MP card with spare. WRONG • The data stored in the memory is wrong. • This message is displayed when too many digits are entered. For example, when as- signing “123” for a service access code when “12” has already been used for an- other service code. Clear present data by entering “CCC”, or en- ter correct data. SEE CMxx YYYY Double assigned error of the same Station Number or trunk. Station Number intended is already assigned to First Data of CMxx Confirm. USE CMxxxx The data is already assigned by another com- mand. Command Number and YY Number already assigned are displayed. Confirm. TRK NOT ASSIGNED The designated trunk is not assigned. Assign the trunk by CM10. xx > xxx: ERROR The first data has been changed by “S” or “-” button, but the station corresponding to that first data is not assigned. Change the first data by “S” or “-” button, or reenter the first data by “CE”.

INFORMATION FOR DATA PROGRAMMING

3. COMMAND REFERENCE TABLE 3.1 List of Commands Table 2-5 provides a list of commands. Table 2-5 List of Commands COMMAND REMARKS CODE FUNCTION 00 01 02 03 04 05 06 07 08 09 System Data Memory All Clear System Data Memory Partial Clear Setting of System Clock Log in/Log out of Password Mode Language Indicated on Multiline Terminal LCD Card Assignment MISC Trunk Number Assignment DTI Trunk/ISDN Trunk Assignment Basic Service Features Additional Service Features 10 11 12 13 15 16 17 18 19 1A 1B 1C 1D Station Number, Trunk Number, and Card Number Virtual-Line Number Station Class-1 Station Class-2 Service Restriction Class Call Pickup Group/Group Diversion Group UCD Group Station Hunting Group Secretary/Group Diversion Station Number Data Station Number ISDN Terminal Multipoints Station Number Assignment PS Station Number Assignment PS-ID Assignment/PS Operation Data Download 20 21 22 23 24 25 26 Numbering Plan Single Digit Access Code Route Advance Tenant Development Kind of Calling Terminal Development Kind of Special Terminal Development Closed Number Development 29 2A Numbering Plan Tenant Group ID Code Assignment with MP 30 31 35 36 38 Trunk Data System Attribute Data Trunk Route Data Restriction Data for Tandem Connection AMP Trunk

INFORMATION FOR DATA PROGRAMMING

40 Function of RS-232C Interface Circuit MP 41 42 44 45 48 System Timer Data System Counter Data/PAD Data/Trunk Restriction Class Conversion External Equipment Starting Condition Purpose of PBR/CFT Determination of Tone/Tone Source 49 Digital Announcement Trunk PN-2DATA 50 51 52 53 Common Route Indial Automatic Transfer Destinations Hot Line Trunk Answer from Any Station Restriction 56 Internal Zone Paging Group/Intercom Group 58 LDN Diversion 59 TAS/ACD/UCD Relay Interruption Pattern For PN-DK00 5A Virtual Line - Virtual Path Setting 60 ATTCON Tenant Group, Functions For ATTCON 61 External Key Function For PN-DK00 62 Tenants for Each ATTCON Group For ATTCON 63 Restriction of Inter-Tenant Connection 64 Automated Attendant 65 Service Features on Tenant Basis 71 72 73 74 76 77 78 Memory Allocation for System Speed Dialing Stored Number for System Speed Dialing Memory Allocation for Station Speed Dialing Stored Number for Station Speed Dialing Digit Conversion on DID Call Station/Trunk Name Assignment Destination of Split Call Forwarding 81 85 88 8A Toll Restriction Pattern on Each Trunk Restriction Class Maximum Digits on C.O. Calls Automatic Pause Entry Table LCR/Toll Restriction Development Table Table 2-5 List of Commands (Continued) COMMAND REMARKS CODE FUNCTION

INFORMATION FOR DATA PROGRAMMING

Table 2-5 List of Commands (Continued) COMMAND REMARKS CODE FUNCTION 90 93 94 96 97 98 9A Multiline Terminal/SN610 ATTCON/Add-On Module Key Assignment Prime Line Multiline Terminal One-Touch Memory DSS Console Number DSS Console Key Assignment Add-On Module Number Multiline Terminal Soft Key Assignment A0 A1 A5 Type of Data Adapter Data Terminal Attribute Data Nailed Down Connection A6 Attribute Data for RS-232C Port on AP01 For PN-AP01 A7 A8 A9 AA AC AD AE AF CCIS Channel Data CCIS Routing Label Assignment ISDN D-Channel Assignment DTI/DCH/CIR Card Functions ISDN Functions ZT Calling Area/PAD Data Assignment ZT Operation Data Assignment Visitor PS Data Assignment B0 B1 B3 PEG Count Traffic Measurement UCD PEG Count Used for maintenance D5 ID Code Assignment with AP D6 ID Code All Clear with AP For PN-AP01 D7 D9 DB DC OAI Control Data Centralized Billing Data Port Assignment Calling Number Development Data Calling Number Development Table E0 E5 E6 E7 E8 E9 EA EC EE Initialization Station Trunk Make Busy Call Forwarding Set/Reset from MAT/CAT Password Level Manual Path Connection Password Code Fault Information Store/Display Functions Battery Release/Line Status Indication Virtual Tie Line Set/Release Used for maintenance F0 F1 F2 F3 F5 F8 MP Memory Dump MP Memory Read/Write FP Memory Dump FP Memory Read/Write Line/Trunk Memory/Alarm Memory Read ID Code for Key FD Used for maintenance

INFORMATION FOR DATA PROGRAMMING

3.2 Quick Reference Table of Commands Required for Service Feature This section provides a quick reference table of various commands related to each service feature. The features are listed alphabetically in the left column. Associated features (shown with bullets) are listed be- low the main features. Note: Table 2-1 provides a list of commands for each business service feature. Table 2-2 provides a list of com- mands for each hotel/motel service feature. F and S represent First Data (F) and Second Data (S), re- spectively. For more details about the data, refer to the Command Description for the associated command.

INFORMATION FOR DATA PROGRAMMING

Table 2-6 List of Commands for Each Business Feature For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY Account Code 08 – 362/S 12 02 F/S 15 30 F/1 20 0 – 3 F/085 42 – 10/S 90 00 F/F0085 Add-On Module 10 – F/S 12 05 F/0 30 18 F/0 41 1 09/S 90 00 – 03 F/S 98 0 F/S Alarm Indications – – – Alphanumeric Display 08 – 255/1 20 0 – 3 F/A10 35 03 F/S 77 0 – 3 F/S Analog Port Adapter 10 – F/S 13 09, 32 – 35 F/S 90 00 F/S 93 – F/S

INFORMATION FOR DATA PROGRAMMING

Announcement Service 08 – 124/S 10 – F/S 12 02 F/S 15 34 – 39 F/1 20 0 – 3 F/A00 – A09 30 03, 05 F/S 35 69 – 73 F/1 41 0 45, 53/S 48 0 F/0500 49 00, 05 – 07 F/S 65 50, 51 F/0 Answer Key 12 02 F/S 15 72 F/0 Attendant-Assisted Calling 08 – 018, 048, 142, 143/S 20 0 - 3 F/800 60 00, 01 F/S 62 0 - 3 F/0 Attendant Camp-On 08 – 068, 441/S 20 0 - 3 F/021 41 0 00/S Attendant Console (SN610 ATTCON) 10 – F/S 30 02, 03 F/14 60 00, 01, 07, 17 F/S 62 0 - 3 F/S 90 00 F/S Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Attendant Console (SN716 DESK CON) 10 – F/S 30 02, 03 F/14 60 00, 01, 15 F/S 62 0 - 3 F/S 90 00 F/S • Attendant Calling/Called Name Display 08 – 255/1 20 0 - 3 F/A10 35 03 F/S 77 0 - 3 F/S • Attendant Called/Calling Number – – – • Attendant Call Selection 35 15 F/S 90 00 F/S • Attendant Console Lockout Password 08 – 353/S 20 0 - 3 F/A55 60 30 0/S 90 00 F/F6110 • Attendant Do Not Disturb Setup and Cancel 13 00 F/0 90 00 F/S • Attendant Interposition Calling/ Transfer 08 – 143/S 20 0 - 3 F/095 90 00 F/F6067 • Attendant Lamp Check – – – • Attendant Listed Directory Number 08 – 204, 205/0 35 15 F/S 50 01, 02 F/S 58 00 - 09 F/S 90 00 F/S Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

• Attendant Loop Release 08 – 014/0 20 0 - 3 F/021 • Attendant Programming 08 – 229/S 20 0 - 3 F/A56 60 30 1/S 90 00 F/611 • Attendant Training Jack – – – • Audible Indication Control – – – • Call Processing Indication – – – • Call Queuing 42 – 00/S • Call Splitting 90 00 F/S • Call Waiting Display 42 – 00/S • Common Route Indial 08 – 204, 205/0 50 01 F/S 58 00 – 09 F/S 90 00 F/S • Dialed Number Identification Service 08 – 204, 205/0 35 15 F/S 50 01, 02 F/S 58 02, 03, 08, 09, 10 F/S 90 00 F/S • Incoming Call Identification – – – • Individual Trunk Access 20 0 – 3 F/081 30 19 F/S • Multiple Console Operation Refer to SN610 ATTCON. Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

• Monitor 08 259 0 15 103 – 15 104 – 20 0 – 3 – 90 00 F0033 • Multi-Function Key 60 17 F/1 90 00 F/F6XXX • Pushbutton Calling - Attendant Only 35 01 F/7 • Serial Call 90 00 F/S • Timer Display – – – • Trunk Group Busy Display 30 09 F/S 44 – F/S 90 00 F/S • Unsupervised Trunk to Trunk Transfer by Attendant 08 – 206/1 Attendant Delay Announcement 08 – 165/S 10 – F/S 20 0 – 3 F/A00-A02 35 74 F/S 41 0 16, 47/S 49 00, 0A F/S Attendant Lockout 08 – 353/S Attendant Overflow 08 – 067/0 30 02, 03, 05 F/S 41 0 01/S Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY Attendant Override 08 – 012, 045, 076/S 12 02 F/S 15 09 F/1 20 0 – 3 F/081 30 19 F/S 90 00 F/F6107 Authorization Code 05 – F/07 08 – 216, 362/S 12 02 F/S 15 31 F/S 20 0 – 3 F/086 42 – 11/S D5 0, 1, 3 F/S 2A 0 – 4 F/S Automated Attendant 08 – 180, 359, 363/S 10 – F/S 20 0 – 3 F/A00 – A02 30 02, 03, 30–33, 37 F/S 41 0 34, 39, 43, 59/S 45 2 F/0 48 2 06/S 49 00 – 02 F/S 63 2 F/S 64 0, 2 F/S

INFORMATION FOR DATA PROGRAMMING

Automatic Call Distribution (ACD) 08 – 212, 214, 215, 227, 259, 265, 357, 442/S 10 F/S 12 02 F/S 15 33, 103, 104 F/1 17 0 – 2, 4 – 7, A, B F/S 20 0 – 3 F/033, 044, 0045, A00 – A02 35 12, 18, 60, 78 F/S 41 0 16, 47/S 42 – 15, 16/S 44 – F/S 49 00 F/S 51 17 F/S 59 – 00/S 76 0, 1, 6 F/S 90 0 F/F0033, F0044, F0120, F1280 – 1295 97 – F/F1055 Automatic Call Distribution (ACD) with Management Information System (MIS) 08 – 068/S Refer to ACD-MIS System Manual 30 13, 14 F/06 Automatic Camp – On 08 – 068/S 30 13, 14 F/06 Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Automatic Number Identification 05 – F08 06 04 F/S 08 – 462, 463, 472/S 09 – 52/0 20 Y F/A26-A29 30 00, 02, 03 F/S 31 1, 2, 3, A, B F/S 35 00, 04, 05, 09, 10, 17, 19, 20, 37, 48 F/S 8A 4XX F/800 Automatic Recall 41 0 00, 05 – 07, 11, 26/S Background Music (BGM) 10 – F/S 12 02 F/S 15 32 F/1 20 0 – 3 F/039 30 00 F/S 35 00 F/05 48 4 F/S Boss/Secretary Calling 08 – 294/S 12 02, 05 F/S 13 03, 08, 12 F/S 15 43, 44 F/S 20 0 – 3 F/040, 041 51 15 F/S 90 00 F/S Broker’s Call Refer to Call Hold Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Call Back 08 – 156/0 12 02 F/S 15 03, 46 F/1 20 0 - 3 F/002 – 005 90 00 F/F0004 Caller ID Class 05 – F/08 06 04 F/S 08 – 462, 463, 472/S 09 – 52/0 30 02, 03 F/S 31 1, 2 F/S 35 00, 37, 44, 48, 129 F/S 90 00 F/F1099, F6122 AA 07 F/S DB 00, 01, 02, 04, 05, 06, 07, 12, 30, 90 - 92 F/S DC 00 - 63 F/S Caller ID Display 90 00 F/F5010 Call Forwarding E6 00 - 05 F/S Set/Reset from MAT/CAT • Attendant Call Forwarding Setup and Cancel – – – Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

• Call Forwarding - All Calls 08 – 222, 386, 387/S 09 – 33/S 12 02 F/S 15 00, 26 F/1 20 0 - 3 F/010, 011 35 05 F/1 36 – F/0 48 2 13/S 65 23 - 25 F/1 90 00 F/F0010 E6 00 F/S • Call Forwarding - Busy Line 08 – 222, 240, 386, 387/S 12 02 F/S 15 11, 12, 28, 29 F/1 20 0 – 3 F/012, 013, 014, 015 35 05 F/1 36 – F/0 65 23 – 25 F/1 90 00 F/F0012, F0014 Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

• Call Forwarding - No Answer 08 – 222, 386, 387/S 12 02 F/S 15 10, 12, 27, 29 F/1 20 0 – 3 F/012, 013, 016, 017 35 05 F/1 36 – F/0 41 0 01, 15/S 65 23 – 25 F/1 90 00 F/F0012, F0016 • Call Forwarding - Destination 12 02 F/S 15 15 F/1 20 0 – 3 F/018, 019 90 00 F/F0018, F0019 • Multiple Call Forwarding - All Calls 42 – 14/S • Multiple Call Forwarding - Busy Line 42 – 14/S • Multiple Call Forwarding - No Answer 41 0 46/S Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

• Split Call Forwarding - All Calls 08 – 222, 386, 387/S 12 02 F/S 15 00, 26 F/1 20 0 – 3 F/010, 011, A80, A81 35 05 F/1 36 – F/0 48 2 13/S 65 23 – 25 F/S 78 – F/S 90 00 F/F0010, F0A80 • Split Call Forwarding - Busy Line 08 – 222, 240, 386, 387/S 12 02 F/S 15 11, 12, 28, 29 F/1 20 0 – 3 F/012 - 015, A82, A83 35 05 F/1 36 – F/0 65 23 – 25 F/S 78 – F/S 90 00 F/F0012, F0014, F0A82 Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

• Split Call Forwarding - No Answer 08 – 222, 386, 387/S 12 02 F/S 15 10, 12, 27, 29 F/1 20 0 – 3 F/012, 013, 016, 017, A82, A83 35 05 F/1 36 – F/0 41 0 01, 15/S 65 23 – 25 F/S 78 – F/S 90 00 F/F0012, F0016, F0A82 • Call Forwarding - Override – – – • Group Diversion 08 – 026/0 16 2 F/S 19 6 F/S 41 0 01/S Call Park – – – • Call Park - System 08 – 133/S 12 07 F/S 15 96 F/S 20 0 – 3 F/008, 009 41 0 05/S 90 00 F/F5000, F6144 • Call Park - Tenant 08 – 133/S 20 0 – 3 F/062 41 0 05/S 90 00 F/F3XXX Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Call Pickup – – – • Call Pickup - Direct 12 02 F/S 15 14 F/1 20 0 - 3 F/021 90 00 F/F0021 • Call Pickup - Group 16 0 F/S 20 0 - 3 F/020 90 00 F/F0020 • Call Pickup - Designated Group 12 02 F/S 15 14 F/1 16 0 F/S 20 0 - 3 F/037 Call Redirect 51 18, 22 F/S 90 00 F/F5011/F5012 Call Transfer – – – • Call Transfer - All Calls 08 – 068, 155, 319/S • Call Transfer - Attendant 08 – 063, 142/S 20 0 - 3 F/800 62 0 - 3 F/0 Camp-On 08 – 050, 051, 068, 069, 146 – 148, 208, 322/S 12 02 F/S 15 16, 43, 44 F/1 20 0 - 3 F/007, A25 41 0 26/S CCSA Access 20 0 - 3 F/100 – 163 35 00, 15 F/S 90 00 F/F6030 – F6037 Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Centrex Compatibility 20 0 – 3 F/A58 35 16, 86 F/S 93 – F/S Class of Service 12 00 – 03, 07 F/S 15 80, 82 – 84, 88 – 91, 96 – 98 F/S 35 51 – 58, 61 – 68 F/S Code Restriction 08 – 035, 044, 119/S 12 01 F/S 35 11, 51 – 55, 76 F/S 81 01 – 13 F/S 85 0 – 4 F/S 8A 400 – 404, 100 – 115, 000 – 063, 500 – 755, 200 – 207, 300 – 303 F/S Conference 08 – 101 – 104, 246/S 45 6, 7 F/1 Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Consecutive Speed Dialing 05 – F/19 08 – 035, 168, 171, 252/S 12 02 F/S 15 07 F/1 20 0 – 3 F/064 – 066 73 – F/S 74 – F/S 90 00 F/S 94 – F/S CMD000 – 56/1 Consultation Hold 08 – 137/0 12 07 F/S 15 88 – 91 F/1 Customer Administration Terminal (CAT) 12 02 F/S 15 56 F/1 E7 00 – 06, 10 – 16 F/S E9 – 0 – 9/S Data Line Security 13 07 F/0 Delayed Ringing 41 1 09/S 90 03 F/0 Diagnostics Refer to Maintenance Manual. Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Dial Conversion 08 – 050, 051/0 10 – F/S 12 00 F/3 35 01, 23 – 26, 45, 46 F/S 45 0, 1 F/1 Direct Digital Interface (DDI) Refer to DDI System Manual. Direct Inward Dialing (DID) 08 – 180/S 10 – F/S 30 00 – 05 F/S 35 00, 02, 05, 12, 18 F/S 41 0 01, 45/S 45 1 F/S 49 00 F/S 51 00, 03, 06 F/S 76 0, 1 F/S Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Direct Inward System Access (DISA) 05 – F/07 08 – 180, 217, 352/S 10 – F/EBXXX 15 33 F/S 20 0 – 3 F/A00, A01 2A 5 – 8 F/S 30 02, 03, 30, 31 F/S 35 18 F/0 41 0 39/S 42 – 13/S 76 0, 1 F/D16 D5 0, 1, 3 F/S Direct Inward Terminator (DIT) 08 – 179/S 30 02, 04, 13, 15 F/S 41 0 01/S Direct Outward Dialing (DOD) 10 – F/S 20 0 – 3 F/100 – 163 30 00, 01, 08 F/S 35 00 – 02, 04, 05, 08, 09, 20 – 26, 45, 46 F/S 41 0 27/S 90 00 F/S Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Direct Station Selection/Busy Lamp Field (DSS/BLF) Console 08 – 269/274/S 10 – F/S 96 – F/S 97 – F/S Distinctive Ringing 08 – 137, 138, 179, 180/S 35 32, 33 F/S Do Not Disturb 08 – 240, 241/S 12 02 F/1 13 00 F/0 15 19 F/1 20 0 - 3 F/022, 023 48 2 14/S 51 10 F/S 90 00 F/S Dual Hold 12 02 F/S 15 64 F/1 E & M Tie Line Access 10 – F/S 35 00 - 02, 04, 05, 08 - 10, 13, 19, 20, 21, 23 - 26, 33, 34, 45, 46, 104, 105 F/S 42 – 50 - 65/S 45 1 F/0 49 00 F/0000, 0E00 51 01, 04, 07 F/EBXXX 63 2 F/S Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Elapsed Call Timer – – – Enhanced 911 05 – F/08 06 04 F/S 08 – 474, 475/S 09 – 52/0 12 12, 13 F/S 13 25 F/S 20 0 - 3 F/A26-A28 31 2 0 - 3/0 35 03, 04, 14, 20, 36, 38, 76, 129 F/S 50 05 F/S 85 0 - 7 F/S 8A YYY F/S AA 07 F/3 Executive Calling 13 21 F/0 Executive Override 08 – 045, 115/S 12 02 F/S 15 05, 09 F/1 20 0 - 3 F/006 45 6 F/1 90 00 F/F0006 Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

External Paging with Meet-Me 08 – 094, 096, 149, 157, 445/S 10 – F/S 12 02 F/S 15 08 F/1 20 0 - 3 F/100 - 163, 070 - 079, 080 30 00, 28 F/S 35 00, 08 F/S 44 – F/S 90 00 F/6150 - F6159 Feature Activation from Secondary Extension – – – FAX Arrival Indicator 12 03, 05 F/00 - 03 13 29 F/0 51 14 00 - 03/S 52 00 - 99 F/S 90 00 F/S Flexible Line Key Assignment 08 252 F/S 12 02 F/S 15 07 F/S 73 – F/S 90 00 F11XX 94 – F/S Flexible Numbering Plan 08 050, 051, 069, 148, 156, 208 F/S 10 – F/S 20 – F/801 - 804 29 0 - 3 F/S Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Flexible Ringing Assignment 08 – 390/1 12 02, 07 F/S 15 68, 83, 84 F/S 35 34 F/S 90 01 F/0 Forced Account Code 05 01 F/07 08 – 216, 362/S 12 02 F/S 15 31 F/1 20 0 - 3 F/087 42 – 11, 12/S 2A 0 - 4 F/S D5 0, 1, 3 F/S D6 0 0000/CCC Group Listening 12 02 F/S 15 70 F/0 Handsfree Answerback – – – Handsfree Dialing and Monitoring – – – Hold – – – • Call Hold 12 02 F/S 15 01 F/1 20 0 - 3 F/046 90 00 F/F0046 • Exclusive Hold 08 – 130/1 41 0 06/S • Nonexclusive Hold – – – Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Hotline 08 – 057/S 11 – F/S 12 03 F/04 52 00 - 99 F/S 71 – 65/S 72 – F/S 90 00 F/S Individual Attendant Access 06 01 F/S 08 – 143/S 10 – F/E000 - E007 20 0 - 3 F/095 Intercept Announcement 10 – F/EB000 - EB127 12 02 F/S 15 33 F/1 20 0 - 3 F/A00 - 02 49 00 F0A00 51 07 F/S Intercom – – – • Manual Intercom 08 – 238/S 11 – F/A200 - A724 12 02, 03 F/S 15 09 F/0 56 11 F/S 90 00 F/A200 - A724 Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

• Automatic Intercom 08 – 237/S 11 – F/A000 - A131 12 03 F/05 13 11 F/S 56 10 F/S 90 00 F/A000 - A131 • Dial Intercom 08 – 239/S 11 – F/B000 - B924 12 02, 03 F/S 15 09 F/0 56 12 F/S 90 00 F/B000 - B924 Internal Tone/Voice Signaling 08 – 050, 051, 069, 148, 156, 270/S 12 02, 07 F/S 15 67, 99 F/S 20 0 - 3 F/A63 Internal Zone Paging with Meet-Me 08 – 158/S 12 02 F/S 15 49 F/1 20 0 - 3 F/A30 - A45, A64 56 00 - 07 F/S 90 00 F/F1270 - F1277 Last Number Redial 08 – 177, 178/S 20 0 - 3 F/069 90 00 F/F0069, F1000, F6121 Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Least Cost Routing 3/6 Digit 20 0 - 3 F/A26 - A28 35 11, 51 - 55 F/S 81 – F/S 85 01 - 13 F/S 8A 5-7, A00 100 - 115 200 - 207 300 - 303 405 - 407, 410 000 - 063 500 - 755 900 - 949 800 - 849 F/S Line Lockout 08 – 153, 274/S 13 04 F/1 41 0 22/S 42 – 01/S Line Preselection 08 – 199/S Maintenance Administration Terminal (MAT) 03 – F/S E7 00 - 06, 10 - 16 F/S E9 – 0 - 9/S • Configuration Report – – – • Maintenance Printout – – – • Peg Count B0 0, 2 F/S B3 0 - 5 F/S • Remove and Restore Service E5 0, 1 F/S Message Center Interface (MCI) Refer to Message Center Interface (MCI) System Manual. Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Message Reminder 08 – 050, 051, 069, 148, 156, 208, 234 - 236, 280 - 294/S 12 02 F/S 13 03 F/0 15 47, 48 F/1 20 0 - 3 F/A46 - A49 51 15 F/S 90 00 F/F1005 Miscellaneous Trunk Access – – – • Code Calling Equipment Access 10 – F/S 20 0 - 3 F/100 - 163 30 00, 01 F/S 35 00, 01, 08 F/S 44 – F/S • Dictation Equipment Access 10 – F/S 20 0 - 3 F/100 - 163 30 00, 01 F/S 35 00, 01, 08 F/S • Foreign Exchange (FX) Access 35 00 F/01 • Radio Paging Equipment Access 08 – 094, 095, 149, 157, 162/S 10 – F/S 12 02 F/S 15 08 F/1 20 0 - 3 F/100 - 163, 070 - 079 30 00, 28 F/S 35 00, 08, 13 F/S 41 0 20/S Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

• Wide Area Telephone Service (WATS) Access 35 00 F/02 Multiline Terminal Attendant Position 08 – 206, 244, 245, 250/S 10 – F/S 11 – F/S 12 02, 03 F/S 15 60, 71, 73 F/S 17 1, 2 F/S 20 0 - 3 F/088 30 02, 04 F/S 51 12 F/S 90 00 F/S 96 – F/S 97 – F/S Music On Hold 08 – 183, 388/S 10 – F/S 12 02 F/S 15 33 F/1 20 0 - 3 F/A00 - A02 44 – F/0000 - 0009 48 0 F/S 49 00, 05 F/S 64 1 F/00 - 09 Night Service – – – • Attendant Night Transfer 08 – 018/S 51 13 F/S • Call Rerouting – – – See Night Connection Fixed/Flexible, TAS, DIT, DID, E&M Tie Line. Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

• Day/Night Mode Change by Attendant Console 20 0 – 3 F/A55 60 30 1/S 90 00 F/F6110 • Day/Night Mode Change by Station Dialing 08 – 244, 245/0 12 02 F/S 15 60 F/1 20 0 – 3 F/043 90 00 F/F0043 • Night Connection - Fixed 30 03, 05, 14, 16 F/S 41 0 01/S • Night Connection - Flexible – – – See Night Connection Fixed and Call Forward- ing - All Calls. • Trunk Answer Any Station (TAS) 10 – F/E800 – E831 12 01, 02 F/S 15 53 F/1 20 0 – 3 F/047 – 051 30 03, 17 F/S 44 – F/S 53 0 – 4 F/S 59 – F/S 63 0 F/S Off-Hook Alarm 12 07 F/S 13 02 F/0 15 97, 98 F/S 41 0 22/S 51 12 F/S 90 00 F/F6056 Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Off-Premises Extension 13 09 F/0 Pad Lock 05 – F/07 08 – 216, 281, 362/S 12 02 F/S 15 31, 75 F/S 20 0 – 3 F/029, 086 2A 0, 1, 3 F/S 42 – 11/S D5 0, 1, 3 F/S D000 – 150/1 D015 – F/S D016 – xx06/1 D031 – F/S Periodic Time Indication Tone 08 – 135, 136/S 12 02 F/S 13 07 F/1 15 61 F/1 41 0 09/S Pooled Line Access 30 00 – 03 F/S 90 00 F/F411 – F4163 Power Failure Transfer 10 – F/S Priority Call 08 – 250, 251/S 12 02 F/S 15 17, 18 F/1 20 0 – 3 F/088, 089 51 12 F/S 90 00 F/F6054, F6055 Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F: First Data S: Second Data —: No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY Privacy/Privacy Release 12 02 F/S 15 63 F/1 Private Line 12 16 F/S 35 98 F/S 42 – 08/S Proprietary Multiline Terminal – – – • Automatic Idle Return 08 – 172/1 • Called Station Status Display – – – • Calling Name and Number Display 08 – 335 • Dynamic Dial Pad 12 02 F/S 15 120 F/0 93 – F/S • Handsfree Unit – – – • I-Hold/I-Use Indication – – – • Microphone Control – – – • Multiple Line Operation 90 01 F/S • Mute Key 90 00 F/F5013 • Off-Hook Voice Announcement 08 – 270, 279/1 11 – F/CX – CXXXX 12 02, 07 F/S 13 28 F/S 15 67, 72, 99 F/S 20 0 – 3 F/A63 90 00 F/CX – CXXXX • Prime Line Pickup 93 – F/S

INFORMATION FOR DATA PROGRAMMING

Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F: First Data S: Second Data —: No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY • Recall Key 35 16, 86 F/1 41 2 17/S 90 00 F/F1009 • Relay Control Function Key 10 – F/E8XX 44 – F/1500 90 00 F/F7XXX

This page is for your notes.

INFORMATION FOR DATA PROGRAMMING

Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY • Ring Frequency Control 08 – 262, 390/S 12 07 F/S 15 83, 84 F/S 35 34 F/S • Soft Key 12 12, 23 90 00 F/F1091 9A 00-03, 10- 13 F/S • Volume Control – – – Remote Hold 12 02 F/S 15 124 F/S 41 0 06/S 90 00 F/F1010 Remote Maintenance – – – Reserve Power – – – Resident System Program – – – See Chapter 4. Return Message Schedule Display 08 – 334 12 02 F/S 15 19 F/1 20 0 – 3 F/A54, 023 Ringing Line Pickup 12 07 F/S 15 82, 86 F/0 Route Advance 20 0 – 3 F/200 – 231 22 00 – 31 F/S Save and Repeat 90 00 F/F1001, F1013, F1014 Security Alarm 12 03 F/04 52 00 – 99 F/S Six-/Ten-Party Conference 10 – F/ED00 – ED03 12 02, 05 F/S 15 69 F/1 20 0 – 3 F/A59 – A62 90 00 F/F0A85, F0A86

INFORMATION FOR DATA PROGRAMMING

Software Line Appearance 11 – F/S 12 01 – 14 F/S 13 12, 13 F/1 90 00 F/S Stack Dial 08 – 178/S 12 07 F/S 15 96 F/S 90 00 F/F1000, F6121 Station Hunting – – – • Station Hunting - Circular 08 – 240/S 18 0, 1 F/S • Station Hunting - Terminal 08 – 240/S 18 0, 1 F/S • Station Hunting - Secretarial 08 – 240/S 18 2 F/S 19 0, 1, 2 F/S Station Message Detail Recording Refer to SMDR System Manual. Station Speed Dialing 05 – F/19 08 – 035, 168, 171, 252/S 12 02 F/S 15 07 F/1 20 0 - 3 F/064 - 066 73 – F/S 74 – F/S 90 00 F/S 94 – F/S CMD000 – 56/1 Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Step Call 08 – 069, 163/1, 208/0 Supervisory Control of Peripheral Equipment 13 22 F/0 41 1 08/S System Speed Dialing 08 – 043, 044, 110 - 112, 176/S 12 02 F/S 15 06 F/1 20 0 - 3 F/067, 068, A50 - A52 41 0 38/S 71 – 00 - 64/S 72 – F/S 74 – F/S Tenant Service 12 04 F/S 20 0 - 3 F/S 23 00 - 23 F/S 29 – F/S 30 01 F/S 49 01 - 07 F/S 51 00 - 12/15 F/S 61 00 F/S 62 0 - 3 F/S 63 0 - 2 F/S 64 0 F/S 65 50/51 F/S 71 – F/S 8A 100 F/S Tie Line Tandem Switching 36 – F/S Timed Queue 41 0 35 – 37/S 90 00 F/F004 Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Timed Reminder 08 – 228/S 10 – F/DB00, E8XX, EBXXX 12 02 F/S 15 13 F/1 20 0 - 3 F/024, 025, A00 – A02 41 0 23, 52/S 42 – 03, 04/S 44 – F/0100 48 1 00/0200, 0500, 1400 49 00, 08 F/S 90 00 F/F0024 Trunk-Direct Appearances 08 – 365/S 30 02, 18 F/S 90 00 F/D000 – D255/F0058 Trunk Queuing - Outgoing 08 – 196/S 12 02 F/S 15 02 F/1 20 0 – 3 F/000, 001, 004, 005 35 28 F/S 90 00 F/F0004 Trunk-to-Trunk Connection 08 – 028, 029/S 10 – F/C100-C163 12 07 F/S 15 90, 91 F/1 35 119 F/S 36 – F/S 38 00–07 F/S 41 0 54, 55/S Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Uniform Call Distribution (UCD) with Overflow 08 – 212, 214, 215, 227, 259, 357, 442/S 10 – F/S 12 02 F/S 15 33, 103, 104 F/1 17 0 – 2, 4 – 7, A, B F/S 20 0 – 3 F/033, 044, 045, A00 – A02 35 18, 60 F/S 41 0 16, 47/S 42 – 15, 16/S 44 – F/S 49 00 F/S 51 17 F/S 59 – 00/S 76 6 F/S 90 00 F/F0033, F0044, F1020, F1280 – 1295 Uniform Numbering – Voice & Data 20 0 - 3 F/A26 - A29 35 17 F/S 50 00 0/S 80 – 0/2 8A A00, 405 - 407, 000 - 063, 500 - 755 F/S Variable Timing Parameters 41 0, 1, 2 F/S Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Table 2-6 List of Commands for Each Business Feature (Continued) For Business System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY Voice Guide 15 116 F/S 41 0 95/S 48 2 12, 13, 14/S 49 00, 13 F/S Voice Mail Integration 08 – 063, 156, 208, 333, 428/S 12 02 F/S 13 03, 10, 13 F/S 15 24, 40 F/1 20 0 – 3 F/040, 041, A46, A47 41 0 00, 14, 44, 48, 49/S 50 00 3, 4/S 51 15, 18 F/S 77 0, 1 F/S 90 00 F/F1005, F5001, F6112, F6113, F6123 Whisper Page 08 – 268, 269/S 12 02 F/S 15 111, 112 F/S 20 0 – 3 F/A88 48 2 17/S 90 00 F/F0A88 Wireless Communication System (WCS) – – – Refer to WCS System Manual

INFORMATION FOR DATA PROGRAMMING

Table 2-7 List of Commands for Each Hotel/Motel Feature For Hotel/Motel System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY Automatic Wake-Up 08 – 228, 282 – 284, 286, 287/S 10 – F/S 12 02 F/S 15 13, 20, 21, 33 F/1 20 0 – 3 F/024, 025, 027, 028, A00 – A02 41 0 23, 52/S 42 – 03, 04/S 44 – F/0100 48 1 00/XX00 49 00, 08 F/S 90 – F/S Check In/Check Out D000 – 11/1 D001 – 12, 13/S D015 – F/S D016 – XX06/1 D031 – F/S Direct Data Entry 20 0 – 3 F/097 90 00 F/F0097 D001 – 252, 253/S D015 – F/S D016 – XX24/S

INFORMATION FOR DATA PROGRAMMING

Do Not Disturb 08 – 240,241/S 12 02 F/S 15 19 F/1 20 0 – 3 F/022, 023 48 2 14/S 51 10 F/S 90 00 F/S Do Not Disturb - System 08 – 240, 241/S 13 00 F/0 48 2 14/S 51 10 F/S 90 00 F/S Hotel/Motel Attendant Console 90 00 F/S Hotel/Motel Front Desk Instrument 02 – 0, 1, 2/S 10 – F/S 12 02 F/S 15 62 F/1 90 00 F/S D000 – 2/1 D001 – F/S D035 – F/S House Phone 08 – 055, 056/S 12 03 F/00 – 03 51 14 00 – 03/S Table 2-7 List of Commands for Each Hotel/Motel Feature (Continued) For Hotel/Motel System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Maid Status 08 – 281/S 20 0 – 3 F/029 90 00 F/F1069 D015 – F/S D016 – XX06/1 D031 – F/S Message Registration – – – Refer to SMDR System Manual Message Waiting 08 – 233 – 235/S 12 02 F/S 13 03, 13 F/S 15 24, 40 F/S 20 0 – 3 F/040, 041, A47 48 2 12/S 51 15 F/S 90 00 F/S Property Management System Interface Refer to PMS System Manual. Room Cut Off 08 – 232/S 51 11 F/S 90 00 F/S D001 – 5, 13/S D015 – F/S D016 – XX06, XX46/1 D031 – F/S D033 – F/S D034 – F/S Room Status Refer to Maid Status Table 2-7 List of Commands for Each Hotel/Motel Feature (Continued) For Hotel/Motel System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

Single Digit Dialing 20 0 – 3 F/808 – 811 21 0 – 3 F/S 41 0 13/S Table 2-7 List of Commands for Each Hotel/Motel Feature (Continued) For Hotel/Motel System F : First Data S : Second Data — : No Data FEATURE COMMAND 1ST DATA/2ND DATA (F/S) REMARKS CODE Y-YYY

INFORMATION FOR DATA PROGRAMMING

4. PRECAUTION 4.1 Conditions for Using Commands (1) Some commands require a system initialization (reset) after assignment/change of the office data, and oth- ers cannot be assigned/changed unless the system is in off-line mode (a state in which call processing is at a halt). These commands are shown in Table 2-8, categorized according to the conditions for their use. Table 2-8 Commands and Their Using Conditions CONDITION COMMAND REMARKS Commands that require a reset of MP card after data setting • System reset is made by pressing SW1 on MP card. CM05: Card Assignment CM06: MISC Trunk Number Assignment CM07: DTI Trunk Assignment CM08 – 390, 391: Basic Service Feature CM09: Additional Service Features CM10: Station Number/Trunk Number, and Card Number (System initialization is required only for assigning the PN-8RST, PN-CFT, ISDN Circuit). CM1A: Data Station Number CM60: YY = 00, 01, 02, 04, 06: ATTCON Tenant Group, Functions CM62: Tenants for each ATTCON Group CMA9: ISDN-channel Assignment CAF8: ID Code for Key FD Commands that require a reset of AP card (PN-AP00) after data set- ting • AP reset is made by moving Make Busy switch UP and then DOWN. CMD001 – 20 – 35 – 80 – 156 Commands that can be used only under Off-Line mode of MP card (see Section 4.2.) CM00: System Data Memory All Clear CM01: System Data Memory Partial Clear CAT cannot use these com- mands. Commands that can be used only under Off-Line mode of AP card (PN-AP00) (See Section 4.2.) CMD100: System Data Partial Clear CMD101: System Data All Clear CMD102: Expansion Memory Clear INITIAL AP INITIAL System Features (2) OFF LINE AP OFF LINE

INFORMATION FOR DATA PROGRAMMING

(2) When deleting data in any command, enter “CCC” as 2nd data. However, data in the following commands cannot be deleted. • Commands where the initial data ( ) is provided but the initial data ( ) is “NONE”. • CM29, CM41, CM42, CM60 YY = 30. 4.2 Method of Setting On-Line/Off-Line Mode (1) For the MP card: (a) Operation for changing on-line mode to off-line mode: • Set SW3 to “2” or “3”. • Press SW1. (b) Operation for changing off-line mode to on-line mode: • Set SW3 to “0”. • Press SW1. For details, refer to the Circuit Card Manual. (2) For the AP card: (a) Operation of changing on-line mode to off-line mode: • Set SW1 as shown below. SW1 OFF 4 3 2 1 ON : POSITION TO BE SET

INFORMATION FOR DATA PROGRAMMING

(b) Operation for changing off-line mode to on-line mode: • Set SW1 as shown below. For details, refer to the Circuit Card Manual. 4.3 Method for Installing Line/Trunk Cards In the PBX, all line/trunk circuits are provided by installing the cards into a card shelf. The PBX employs a flexible port assignment architecture in which the system allocates a port (Time Slot) to each LEN (Line Equipment Number) according to system data. Consider the following conditions before installing cards: • Number of Time Slots within Unit • Card installation location (1) Number of Time Slots Figure 2-2 Line/Trunk Card Installation Location SW1 OFF 4 3 2 1 ON : POSITION TO BE SET L T 0 0 L T 0 1 L T 0 2 L T 0 3 L T 0 4 L T 0 5 L T 0 6 L T 0 7 L T 0 8 L T 0 9 L T 1 0 L T 1 1 L T 1 2 L T 1 3 L T 1 4 L T 1 5 A P 6 M P / F P / A P 7 B U S / A P 8 P W R BUILT-IN BATTERY * PIM 0 - 7 * Application cards can be mounted also in LT10 through LT15 slots.

INFORMATION FOR DATA PROGRAMMING

• Number of ports on each card Each card slot has four (4) LENs. For the relation between Slot Numbers and LENs, refer to the “Port Assignment Table” of the Office Data Programming Manual. Note: When performing the 10-party conference, two PN-CFTA cards are needed. In this case, the total num- ber of time slots is 20. • The following two conditions should be considered for the PBX: Table 2-9 Port Assignment on Each Line/Trunk Card X: Assignment possible –: Assignment not possible CARD NAME LEN TO BE ASSIGNED ON EACH LTXX NUMBER OF CIRCUITS NUMBER OF TIME SLOTS LEVEL 0 LEVEL 1 LEVEL 2 LEVEL 3 PN-4COT X X X X 4 4 PN-4LC X X X X 4 4 PN-4DLC X X X X 4 4 PN-2DLC X X – – 2 2 PN-2DATA X – X – 2 2 PN-2ODT X X – – 2 2 PN-8RSTA X – X – 8 8 PN-AUCA X X – – 2 2 PN-CFTA X – – – 8 10 PN-DK00 X – X – 8 0 PN-TNTA X – X – 2 4 PN-2DPCB X – X – 2 2 PN-2AMPA X – X – 2 4 PN-2ILCA X X – – 2 5 Number of time slots within any PIMs (0 - 7) ≤ 64 time slots Number of time slots per System ≤ 512 time slots

INFORMATION FOR DATA PROGRAMMING

4.4 Password Entry In a system with password service, a maintenance person is required to enter an authorization level num- ber (Password Level) and appropriate password prior to engaging in programming the system data with the MAT/CAT. A maximum of eight (8) Password Levels can be set up. The number of commands that the maintenance person can access is determined by the password level. Password and accessible com- mands for each Password Levels are determined by system data. The procedure for programming, with password, is shown below: STEP 1 Connect the MAT to the system, and turn the power switch on. For the CAT, change the mode to CAT. STEP 2 Enter the password by CM03. Operation: – “OK” will be displayed, if accepted In case of “DATA ERROR”, the password is incorrect. STEP 3 Start programming. STEP 4 When programming is completed, set the following data by CM03. Operation: – Programming without password is restricted. Note: For the details of data assignment for password service, refer to CME7, CME9 in Chapter 3, DESCRIP- TION OF COMMANDS. Table 2-10 shows the example for the Password Level Table. Note: All levels can access CM03. Table 2-10 Example of Password Level Assignment MAINTENANCE PERSONNEL PASSWORD LEVEL ACCESIBLE COMMANDS A B C D E F Level 7 Level 4 Level 3 Level 2 Level 1 Level 0 All commands CM05, 08 - 13, 15 - 26, 30, 35, 36 CM08 - 13, 15, 30, 35 CM10, 11, 30, 35 CM10, 11 CM10 + 03 + + Password Level No. + + Password + ST DE DE EXE + 03 + + 9 + + CCCCCCCC + ST DE DE EXE 8 digits

DESCRIPTION OF COMMANDS

CHAPTER 3 DESCRIPTION OF COMMANDS 1. GENERAL This chapter provides a detailed description for each command. 2. DETAILED DESCRIPTION OF COMMANDS This section describes the methods for programming commands. Information about each command is present- ed in the following order: (1) Function: The function of the command. (2) Precaution: Precautions related to assigning data. (3) Assignment Procedure: The procedure for assigning data. (4) Data Table: A detailed description of the data. In the description of each command, initial data which is automatically loaded into memory, after system ini- tialization (using position “B” on SW3 of the MP, followed by a reset) is indicated with “ ”. Refer to Chap- ter 4 for details on default data when the automatic resident program function (using position “C” on SW3 of the MP, followed by a reset) is used. The installer should confirm the meaning of initial data, and change or delete the data, if required. If under the command code designation there is an abbreviation, then programming can be accomplished by the MAT mode of programming instead of the MOC mode or CAT mode. MAT

SYSTEM DATA MEMORY ALL CLEAR

00 [CM00] System Data Memory All Clear 4. DATA TABLE: 1. FUNCTION: This command confirms that the system data memory (RAM) area can be Written-in /Read-out and also assigns the Initial Data to the RAM area. 2. PRECAUTION: (1) This command can only be used in off-line mode. (2) When this command is executed, “OK” displays with Memory Clear completed (about 30 seconds later). (3) If an error exists in memory, “WD ERROR” displays. (4) This command is not available with a CAT. To clear all system data, set SW3 to “B”, and press SW1 on the MP card. In this case, the only functional port is LEN0000, which is assigned as a CAT. 3. ASSIGNMENT PROCEDURE: 1ST DATA 2ND DATA DATA MEANING DATA MEANING 1 System data memory all clear CCC Clear 3 System data clear for new memory area Note: This data is available when using PN-CP00-C/CP02-C/CP03-C card. CCC Clear + 00 + + + + + CCC MEMORY AREA EXE ST DE DE DESIGNATION (1/3)

SYSTEM DATA MEMORY PARTIAL CLEAR

01 4. DATA TABLE: 1. FUNCTION: This command is used to clear the data associated with the Numbering Plan (CM20-CM29) or Toll Restriction (CM85-CM8A). 2. PRECAUTION: This command can only be used in off-line mode. 3. ASSIGNMENT PROCEDURE: CLEAR DESIGNATION SYSTEM DATA TO BE CLEARED REMARKS 20 CM20: Assignment of Numbering Plan CM21: Assignment of Single Digit Access Code CM22: Assignment of Route Advance CM23: Assignment of Tenant Development CM24: Assignment of Kind of Calling Terminal Development CM25: Assignment of Kind of Special Terminal Development CM26: Assignment of Closed Number CM29: Assignment of Numbering Plan Tenant Group 80 CM85: Assignment of Maximum Number of Digits on C.O. Call CM88: Assignment of Dialed Digit requiring an automatic pause CM8A: Assignment of LCR/Toll Restriction Development Table 740 Clears Guest Name memory area + 01 + + + + + CCC 80 Commands to be cleared: 20, 21, 22, 23, 24, 25, 26 and 29 in Data Memory Commands to be cleared: 85, 88 and 8A in Data Memory EXE ST DE DE + 01 + + + + + CCC 20 EXE ST DE DE + 01 + + + + + CCC 740 EXE ST DE DE [CM01] System Data Memory Partial Clear

SETTING OF SYSTEM CLOCK

02 MAT 4. DATA TABLE: 1. FUNCTION: This command is used to assign clock data (day, date and time). 2. PRECAUTION: (1) The system clock starts when EXE is depressed. (2) Reenter all the Clock Data if “HARD ERROR” is displayed as a result of this command. (3) This command is included in MAT mode menu “E1” (Setting of System Clock [COM02]). 3. ASSIGNMENT PROCEDURE: SECTION NO. DATA MEANING REMARKS 0 [Date (YYYY)] 0000 - 9999 The calendar year is set by 4 digits. 1 [Date (MM/DD)] 010100 - 123106 Month, Date and Day are set by 2 digits each in the order named. Days are set as follows: SUN: 00, MON: 01, TUE: 02, WED: 03, THU: 04, FRI: 05, SAT: 06 2 [Time (HH:MM:SS)] 000000 - 235959 Hour, Minute, and Second are set by 2 digits each in the order named. Hour information is set in military format (24-hour). For example: 2 p.m. is set as “140000”. SEC. + 02 + + + + + DATA EXE ST DE DE SECTION No. (0, 1 or 2) (4/6 digits) MIN. HR. XX XX XX DAY DATE MONTH XX XX XX [CM02] Setting of System Clock

LOG IN/LOG OUT OF PASSWORD MODE

03 Note 1: The password for each level is set by CME9. The allowed commands for each Password Level are defined with CME7. Note 2: “OK” is displayed when the login is successful. Note 3: For security purposes, when entering a password, “*” is displayed. Note 4: The password mode is automatically logged out unless a command is entered within 10 minutes after logging in. 1. FUNCTION: This command is used to enter a password which allows authorized personnel to access commands in accordance with preassigned authorization levels. 2. PRECAUTION: None 3. ASSIGNMENT PROCEDURE: To log in the password mode and enter the password + 03 + + + + + PASSWORD PASSWORD LEVEL (0 - 7) EXE ST DE DE + 03 + + + + + CCCCCCCC 9 EXE ST DE DE (1 digit) (Max. 8 digits) To log out of the password mode 8 digits [CM03] Log In/Log Out of Password Mode

LANGUAGE INDICATED ON MULTILINE TERMINAL LCD

04 INITIAL 4. DATA TABLE: 1. FUNCTION: This command selects the language that displays on the Multiline Terminal LCDs. 2. PRECAUTION: This command requires a system reset after setting the data. 3. ASSIGNMENT PROCEDURE: : Initial Data Y 1ST DATA 2ND DATA DATA MEANING DATA MEANING 00 00 Selected language for Multiline Terminal LCD 0 1 2 7 Japanese English French Depends on Nation Code (Japanese/English) + 04YY + + + + + 1ST DATA EXE ST DE DE (2 digits) 2ND DATA (1 digit) [CM04] Language Indicated on Multiline Terminal LCD

This command is used to inform the main processor card (CP00 or CP03) of the SENSE switch (sense

wheel) setting on each AP circuit card that is installed. 2. PRECAUTION: (1) This command requires a system reset after setting the data. (2) This command is included in MAT mode menu “E2” (Board Assignment [COM02]). 3. ASSIGNMENT PROCEDURE: : Initial Data SENSE WHEEL (AP NO.) SETTING DATA RELATED COMMAND REMARKS DATA MEANING 04 – 15 04 Hotel/SMDR/Centralized Building–CCIS (PN-AP00-A) 07 Authorization Code, Forced Account Code, OAI (PN-AP01) 08 MF Receiver Trunk (PN-4RSTB/ PN-4RSTC)/911 Sender Trunk (PN-4RSTB) 09 DTI (PN-24DTA/PN-24DTA-A/PN-30DTC/ PN-30DTC-A) 10 BRI (PN-BRTA/PN-2BRTC) 11 Common Channel Handler (PN-SC00) 12 D Channel Handler (PN-SC01) 13 ISDN Channel Handler (PN-SC02/SC03) 15 This slot is not used. 19 Memory Expansion Card (PN-ME00) 23 ZT Handler (PN-SC03) 34 Data Base Module (DBM) (PN-AP00-A) 35 D Channel Handler for Roaming (PN-SC01) + 05 + + + + + SENSE WHEEL EXE ST DE DE (2 digits) DATA (2 digits) [CM05] Card Assignment

Note: Set the SENSE switch on the AP circuit card to match an unequipped slot number as shown below.

SENSE WHEEL (04 - 15) 04 05 06 07 08 09 10 11 12 13 14 15 SWITCH SETTING VALUE 4 5 6 7 8 9 A B C D E F

MISC. TRUNK NUMBER ASSIGNMENT

06 4. DATA TABLE: 1. FUNCTION: This command assigns Miscellaneous Trunk Numbers to each card. 2. PRECAUTION: This command requires a system reset after setting the data. 3. ASSIGNMENT PROCEDURE: YY MISC. TRUNK NO. AP NUMBER + CIRCUIT NUMBER RELATED COMMAND 04 00 ~ 15 MF Receiver /911 Sender Trunk 00 – 15 XXX XX X Circuit Number (0 – 3) Slot Number (04 – 15) assigned by CM05 CM05 07 0 ~ 3 CCH (Common Channel Han- dler) Number 0 ~ 3 XX XX Slot Number (04 – 15) of PN-SC00 CM05 CM30 CM35 CMA7, CMA8 08 0 ~ 4 DCH (D Channel Handler) Number 0 ~ 4 XX XX Slot Number (04 – 15) of PN-SC01 CM05 CM35 YY = 93 09 00 ~ 11 ICH (ISDN Channel Handler) Number 00 ~ 11 XX XX Slot Number (04 – 15) of PN-SC02/PN-SC03 CM05 10 XX XX Slot Number (04 – 15) of PN- SC03 + D Channel Block Number (00 – 03) XXXX XXXX LEN of PN-2CSI (0000, 0004-0504, 0508) CM05 + 06YY + + + + + ST DE 1ST DATA (1-4 digits) DE 2ND DATA (2-4 digits) EXE [CM06] Misc. Trunk Number Assignment

DTI TRUNK/ISDN TRUNK ASSIGNMENT

07 4. DATA TABLE: 1. FUNCTION: This command assigns the DTI/ISDN trunks. 2. PRECAUTION: This command requires a system reset after setting the data. 3. ASSIGNMENT PROCEDURE: YY 1ST DATA 2ND DATA RELATED COMMAND DATA MEANING DATA MEANING 01 XXXX Channel No. of 24-DTI/30-DTI XX XX Channel No. for 24-DTI: 00-23 for 30-DTI: 01-15, 16-31 Slot Number assigned by CM05 DXXX Trunk Number (D000 – D255) Note: Trunk numbers already assigned by CM10 cannot be used. CM05 CMA9 YY=00 02 XXXX Channel No. of BRT XX XX Channel No. for PN-BRTA: 00/01 for PN-2BRTC: 00-03 Note: Be sure to assign the trunk numbers to all circuits (00-03) of the PN-2BRTC card, even if only one PCM digital line is accom- modated to the card. Set make-busy to the unused trunk numbers by CME5 Y=1. Slot Number assigned by CM05 DXXX Trunk Number (D000 – D255) Note: Trunk numbers already assigned by CM10 cannot be used. CM05 + 07YY + + + + + 1ST DATA EXE ST DE DE (4 digits) 2ND DATA (4 digits)

DTI TRUNK/ISDN TRUNK ASSIGNMENT

07 YY 1ST DATA 2ND DATA RELATED COMMAND DATA MEANING DATA MEANING 05 32XX Virtual Channel No. 32 XX Home-Side Trunk Virtual Channel No. 00 – 30 (Even No.) Mate-Side Trunk Virtual Channel No. 01 – 31 (Odd No.) DXXX Trunk Number (D000 – D255) Note: Trunk numbers already assigned by CM10 cannot be used.

THIS PAGE INTENTIONALLY LEFT BLANK.

CHAPTER 3 ND-45669 (E) Page 70-2 Addendum-002 Revision 2.2 JANUARY, 1999 This page is for your notes.

BASIC SERVICE FEATURES

08 1. FUNCTION: This command is used to assign basic features on a system-wide basis. 2. PRECAUTION: After setting 1st data 390 and 391, system reset is required. 3. ASSIGNMENT PROCEDURE: + 08 + + + + + ST DE BASIC SERVICE FEATURE (3 digits) DE DATA (0/1) (1 digit) EXE [CM08] Basic Service Features

BASIC SERVICE FEATURES

08 4. DATA TABLE: : Initial Data BASIC SERVICE FEATURE SETTING DATA 012 Busy Verification 0 1 Not available Available 014 Attendant Loop Release 0 1 Provided Not provided 018 When the system is in night mode, an attendant (dial “0”) call from a station is automatically transferred to a specific sta- tion. 0 1 Not transferred To transfer (See CM51 YY = 13) 021 Station to Station call during a C.O. outgoing connection or outgoing call transfer. 0 1 To restrict Not restricted 025 MSG Display 0 1 MSG (only) MSG X (X: No. of message) 026 Group Diversion 0 1 Available (See CM16 Y = 2) Not available 028 C.O. to C.O. transfer by station or attendant. Note: This data is effective for C.O. Trunks (Ground Start/Loop Start) which receive a release signal from the C.O. 0 1 To allow Not allowed 029 When tandem call duration passes a predetermined time, the call is disconnected or continued. 0 1 To disconnect To continue 032 When a dial-in incoming call from a tie line or DID line is ad- dressed to vacant levels or unassigned stations, the call is routed to a predetermined station, ATTCON or Digital An- nouncement Trunk. 0 1 Restricted (Reorder) Predetermined station, ATTCON, or Digital Announcement Trunk assigned by CM51 YY = 06, 07 035 Toll Restriction for an outgoing call by Station Speed Dialing feature. 0 1 Not provided To provide 036 Buzzer indication when a call remains held at the ATTCON over a preprogrammed period of time assigned by CM41 Y = 0, Function No. 00 (Buzzer indication for Automatic Recall) 0 1 Not available Available 037 Select the detection method of IC GS Trunks Ring signal. Note: This is useful when AC induction is present on GS Trunks. 0 1 Detect only, Ring cycle only Detect Ring cycle and Ground Lead 040 SMDR output for Tandem Call 0 1 Available Not available 043 System Speed Dialing Security (Stored Number display on Multiline Terminal for an outgoing call by System Speed Dialing). 0 1 Not displayed Display

BASIC SERVICE FEATURES

08 044 Toll Restriction for outgoing call by System Speed Dialing feature. 0 1 Not provided Provide 045 Warning tone sent to connected parties during Executive Override or Attendant Override. 0 1 Only once Every 4 sec. 048 Passing Dial Tone facility 0 1 Not available Available 050 If * button on DTMF telephone is pressed while hearing busy tone, it is regarded as a Switch Hook Flash. 0 1 Effective Ineffective 051 If # button on DTMF telephone is pressed while hearing busy tone, it is regarded as a Switch Hook Flash. 0 1 Effective Ineffective 053 Alternative ISDN line for Event Based CCIS 0 1 Available Not available 055 Result of a Switch Hook Flash on a telephone that belongs to House Phone Group 0 or 1. 0 1 Special Dial Tone (Dialing is available) Attendant Recall 056 Result of a Switch Hook Flash on a telephone that belongs to House Phone Group 2 or 3. 0 1 Special Dial Tone (Dialing is available) Attendant Recall 057 Result of a Switch Hook Flash on a telephone assigned as a Hot Line. 0 1 Special Dial Tone (Dialing is available) Attendant Recall 058 Destination selection method for Day/Night Mode Change, when Direct Inward Dialing terminates. Effective only when the 2nd data of CM08-264 is 1. 0 1 For station tenant For trunk tenant 062 Call transfer from a station before called station answers. 0 1 Not available Available 063 Call transfer from a station before called ATTCON answers. 0 1 Available Not available 067 Attendant Overflow 0 1 Available Not available 068 Camp-On Tone sending to a busy station by Camp-On Trans- fer method 0 1 Camp-on Tone sent out only once Camp-on Tone repeats at 4 second intervals. 069 When a station user has dialed any one digit while hearing busy tone 0 1 Switch Hook Flash Step Call 076 Warning tone to be sent to C.O. line, when a station or opera- tor overrides a busy station connected to a C.O. line 0 1 Not sent Send : Initial Data BASIC SERVICE FEATURE SETTING DATA

BASIC SERVICE FEATURES

08 : Initial Data BASIC SERVICE FEATURE SETTING DATA 078 This setting determines the trunk seizing sequence when CM 35 YY = 83 is set to 0. Note: When NEAX 2000/1000IVS is installed with loop- start trunks, it is important to select the highest available trunk setting to prevent call collisions. 0 1 Highest available trunk Lowest available trunk 085 Types of PS No-Answer timer 0 1 No Answer timer (CM41 • Y = 0-86) No Answer timer (CM41 • Y = 0-01) 086 Whether PS Out of Cell/PS Power Off are separated from No- Answer. Note: This data is effective only when CM08-086 is set to 0. 0 1 Separated Not separated (Handled as No-Answer) 088 Whether the Home PBX Numbering Plan is the Open Num- bering System or Closed Numbering System. 0 1 Closed Numbering System Open Numbering System 094 Paging access tone sent to station 0 1 Send Not sent 095 Hook flash (break pulse) sent to Radio Paging equipment from station 0 1 Send Not sent 096 Hook flash (break pulse) sent to Speaker Paging equipment from station 0 1 Send Not sent 101 When data for “102” is “0” (For Single Line Telephone) 0 1 The call with STA-B is disconnected, and STA-A returns to STA-C. Three-Party Conference 102 When the station (STA-A), after holding the other station (STA-C), has made a switch hook flash while talking with an- other station (STA-B). This data is applied to single line telephone station. 0 1 See the data for “101”. STA-B is held, and STA-A returns to the connection with STA-C. (Broker’s Call) 103 When the station (STA-A), after holding a C.O. call, has made a switch hook flash while talking with another station (STA-B). 0 1 See the data for “104”. STA-B is held, and STA-A returns to the connection with the C.O. line. (Broker’s Call) 104 When the data for “103” is “0” 0 1 The call with STA-B is disconnected, and STA-A returns to the C.O. line. Three-Party Conference 109 Periodic record tone on live record 0 1 Send Not sent

BASIC SERVICE FEATURES

08 : Initial Data BASIC SERVICE FEATURE SETTING DATA 110 1000-Slot Memory Block Number “3” for Station Speed Di- aling is used as the Memory Block for System Speed Dialing. 0 1 Available (See CM20, A50) Not available 111 1000-Slot Memory Block Number “1” for Station Speed Di- aling is used as the Memory Block for System Speed Dialing. 0 1 Available (See CM20, A51) Not available 112 1000-Slot Memory Block Number “0” for Station Speed Di- aling is used as the Memory Block for System Speed Dialing. 0 1 Available (See CM20, A52) Not available

THIS PAGE INTENTIONALLY LEFT BLANK.

CHAPTER 3 ND-45669 (E) Page 74-2 Addendum-001 Revision 2.1 AUGUST, 1998 This page is for your notes.

BASIC SERVICE FEATURES

08 113 Outgoing C.O. Line Call from a Station to Station connection. 0 1 Not allowed To allow 114 Answer preference for enhanced Trunk Direct Appearance 0 1 Display 2-digit trunk ID code (CM30 YY = 19, last two digits assigned) Display 4-digit trunk ID code (CM30 YY = 19) 115 A station user is allowed to break into a call between a C.O. line party and another station by Executive Override. 0 1 Not allowed To allow 116 Answer Key rings Note: Answer key rings on TAS and Pooled Line. 0 1 To provide Not provided 117 While the station (STA-A) is talking with another station (STA-B), after consultation hold with a C.O. call. When STA- B has hung up. 0 1 STA-A returns to the call with the C.O. line. STA-A hears ROT. 119 Toll Diversion When the station dials restricted area code after C.O. Trunk Access code. 0 1 Diversion to attendant “ICPT” The station receives Reorder Tone 120 GUEST NAME DISPLAY (time to display on LCD) Note: This data is only available when CM08-128 = 0. 0 1 10 sec. 6 sec. 121 GUEST NAME DISPLAY Note: This data is only available when CM08-128 = 0. 0 1 Duration of Call CM08 - 120 123 When a station has originated a call to C.O. line via the trunk route assigned to 1 by CM35 YY = 04, and answer signal has not been detected within the preprogrammed time after dial- ing, a pseudo-answer signal is generated. (CM41 Y = 0, Func- tion No. 03) 0 1 Not sent To send 124 Multi-Connection of Digital Announcement Trunk on An- nouncement Service. 0 1 Available Not available (Single Connection) 125 After holding an incoming C.O. call, an attendant dials a sta- tion. If, after connection with the attendant, the called station goes on-hook, the attendant hears Reorder Tone or returns to the held call. 0 1 Return to held call Reorder tone 128 Guest Name Display via PMS. 0 1 Available Not available 130 Exclusive Hold (E-HOLD) Service on Multiline Terminal. 0 1 Not available Available : Initial Data BASIC SERVICE FEATURE SETTING DATA

BASIC SERVICE FEATURES

08 133 A trunk line placed in Consultation Hold by Call Park-Sys- tem/Tenant, can be retrieved by pressing a trunk line appear- ance key on any Multiline Terminal. 0 1 Not available Available 135 Periodic Time Indication Tone Sending for C.O. Line connec- tion. (CM41 Y = 0, Function No. 09) 0 1 To send Not sent 136 Periodic Time Indication Tone Sending for a Tie Line con- nection (When the data for 135 of CM08 is 0). 0 1 To send Not sent 137 Ringing Signal for a station call with a trunk line placed in Consultation Hold. 0 1 Change from Internal to External Ringing when caller goes on-hook or presses RLS key (CM08-138) External Ringing (CM35 YY = 33) 138 Ringing signal for a Station to Station Connection. 0 1 2s ON - 4s OFF 1s ON - 2s OFF 139 Individual Trunk Access from a station. (CM20-081) (Where data is set as “0”, ORT and SENDER are not being timed out. Set data as “1” normally.) 0 1 For testing Normal 141 To record Station to Station calls automatically 0 1 Starts automatically Not available 142 Attendant access capability provided from the stations be- longing to a tenant with no ATTCON. 0 1 To allow Not allowed 143 Calling the designated ATTCON from a station within anoth- er tenant is restricted (CM20 - 095) 0 1 To restrict Not restricted (Recall transferring station) 145 Outgoing call preset or Call answer preset of Multiline Termi- nal • Outgoing preset: + • Call answer preset: + 0 1 Available Not available 146 Transferred C.O. call to a busy station is automatically Camped-on when transferring station goes on-hook. 0 1 Available Not available (Recall transferring station) 147 When a station transferring a C.O. call to a station, which is busy, has performed a switch hook flash. 0 1 Special Dial Tone, allowing the use of Camp-On access code. Return to C.O. line call 148 When a station user, upon encountering the called station busy, has dialed the same last digit again while hearing busy tone. (Effective only when data for “069” is “1”.) 0 1 Switch Hook Flash Ineffective : Initial Data BASIC SERVICE FEATURE SETTING DATA FNC OG FNC ANS

BASIC SERVICE FEATURES

08 : Initial Data BASIC SERVICE FEATURE SETTING DATA 149 In delay-type paging, when the paged party encounters a busy paging circuit, Call Back is automatically set. (Applicable to both Radio Paging and Speaker Paging.) 0 1 To set Not set 150 Restriction of a station to station call between tenants by CM63 Y=1 is temporarily cancelled by external key. 0 1 To cancel Not cancelled 151 Dialing 1 for switch hook flash (DP Telephone) / switch hook flash (DTMF / DP Telephone). 0 1 Not available Available 153 Howler Tone sent to locked-out stations. 0 1 Not sent To send 155 When a station user dials the digit “1” upon encountering a trunk busy. 0 1 Switch Hook Flash Ineffective 156 Dialing of a Single Digit Feature Access Code while the call- ing station hears RBT or performs a Voice Call. 0 1 To allow Not allowed 157 Whether the Paging Answer code and the Paging Access code are to be the same or not. If codes are the same, paging access codes must be set to trunk routes (in CM30 YY=00), as follows: Paging Answer Zone 0 : Trunk Route 50 9 : Trunk Route 59 CM20, 1st data=070 – 079, are used to set the combined access/answer codes. 0 1 Same Different 158 All Zone Internal Paging. 0 1 Not available Available 161 Transfer a trunk line placed in Consultation Hold. (Hold Transfer) 0 1 Available (Hold Transfer) Not available (Consultation Hold) 162 If the multiple Radio Paging access is available after access- ing a Radio Paging Trunk with delay type Radio Paging. 0 1 Not available Available 163 Step Call for an Incoming Call from a Tie Line. 0 1 Not available Available 165 Replaying of a message recorded in the Digital Announce- ment Trunk for Attendant Delay Announcement. 0 1 The message is replayed at an interval. (See CM41 Y=0, Function No. 47) The message is replayed only once. 168 When the DTMF station or Multiline Terminal station dials “#” during the setting of Station Speed Dialing feature. 0 1 “#” is set as paused data (1.5 sec.) “#” is set as called number to C.O. line. ~ ~

DTI TRUNK/ISDN TRUNK ASSIGNMENT

07 YY 1ST DATA 2ND DATA RELATED COMMAND DATA MEANING DATA MEANING 05 32XX Virtual Channel No. 32 XX Home-Side Trunk Virtual Channel No. 00 – 30 (Even No.) Mate-Side Trunk Virtual Channel No. 01 – 31 (Odd No.) DXXX Trunk Number (D000 – D255) Note: Trunk numbers already assigned by CM10 cannot be used.

THIS PAGE INTENTIONALLY LEFT BLANK.

CHAPTER 3 ND-45669 (E) Page 70-2 Addendum-002 Revision 2.2 JANUARY, 1999 This page is for your notes.

Other PBX Manuals