Quadra-Fire MTV-E2-CSB Owner's Manual

Text of the manual

October 27, 2014

O-T L Tested and Listed by Portland Oregon USA OMNI-Test Laboratories, Inc. C US MT. VERNON E2 PELLET STOVE Model(s): MTV-E2-CSB MTV-E2-MBK MTV-E2-PFT MTV-E2-PDB MTV-E2-PBK MTV-E2-PMH Please read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury or even death 061-S-83-2 NOTICE: DO NOT DISCARD THIS MANUAL Owner’s Manual Operation & Care INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. Contact your dealer with questions regarding installation, operation or service. HOT SURFACES! Glass and other surfaces are hot during operation AND cool down. Hot glass will cause burns. • Do not touch glass until it is cooled • NEVER allow children to touch glass • Keep children away • CAREFULLY SUPERVISE children in same room as fi replace. • Alert children and adults to hazards of high temperatures • High temperatures may ignite clothing or other fl ammable materials. • Keep clothing, furniture, draperies and other fl ammable materials away. WARNING Please read this entire manual before use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury, or death. • Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • Do NOT burn garbage or fl ammable fl uids such as gasoline, naphtha, or engine oil in room heater. • Do not overfi re - If heater or chimney con- nector glows, you are overfi ring. Overfi ring will void your warranty. • Comply with all minimum clearances to combustibles as specifi ed. Failure to comply may cause house fi re. WARNING CAUTION Tested and approved for wood pellets and shelled corn only. Burning of any other type of fuel voids your warranty. NOTE To obtain a French translation of this manual, please contact your dealer or visit www.quadrafi re.com 00Pour obtenir une traduction française de ce manuel, s’il vous plaît contacter votre revendeur ou visitez www.quadrafi re.com NOTE A 2:1 mix of pellets to corn is approved, but may require the fi repot to be cleaned more frequently. CAUTION Check building codes prior to installation. • Installation MUST comply with local, regional, state and na- tional codes and regulations. • Consult local building, fi re offi cials or authorities having juris- diction about restrictions, installation inspection, and permits.

October 27, 2014

MT. VERNON E2 B. Sample of Serial Number / Safety Label LOCATION: Back of Stove Serial No. Model Name Test Lab & Report No. Mfg. Date HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS. CAUTION: CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS. ATTENTION: Mt Vernon E2 Pellet Stove R SERIAL NO. / NUMÉRO DU 007058 Listed Solid Fuel Room Heater/Pellet Type. Also suitable for Mobile Home Installation. This appliance has been tested and listed for use in Manufactured Homes in accordance with OAR 814-23-9000 through 814-23-909. Appareil de chauffage de combustible solide/de type de boulettes. Accepté dans l'installation dans les maisons mobiles. Cet appareil a été testé et enregistré pour l'usage dans les Maisons Mobiles en accord avec OAR 814-23-9000 jusqu'à 814-23-909. PREVENT HOUSE FIRES / PRÉVENTION DES FEUX DE MAISON Install and use only in accordance with manufacturer's installation and operating instructions. Contact local building or fire officials about restrictions and inspection in your area. WARNING - FOR MOBILE HOMES: Do not install appliance in a sleeping room. An outside combustion air inlet must be provided. The structural integrity of the mobile home floor, ceiling and walls must be maintained. Refer to manufacturer's instructions and local codes for precautions required for passing chimney through a combustible wall or ceiling. Inspect and clean vent system frequently in accordance with manufacturer's instructions. DO NOT CONNECT THIS UNIT TO A CHIMNEY SERVING ANOTHER APPLIANCE. Use a 3" or 4" diameter type "L" or "PL" venting system. Installez et utilisez en accord avec les instructions d'installation et d'opération du fabricant. Contactez le bureau de la construction ou le bureau des incendies au sujet des restrictions et des inspections d'installation dans votre voisinage. Ne pas obstruez l'espace en dessous de l'appareil. AVIS - Pour Les Maisons Mobiles: Ne pas installer dans une chambre à coucher. Un tuyau extérieur de combustion d'air doit être installé et ne doit pas être obstrué lorsque l'appareil est en usage. La structure intégrale du plancher, du plafond et des murs de la maison mobile doit être maintenue intacte. Référez vous aux instructions du fabricant et des codes locaux pour les précautions requises pour passer une cheminée à travers un mur ou un plafond combustibles, et les compensations maximums. Inspectez et nettoyez la cheminée fréquemment. Ne pas connecter cet appareil à une cheminée servant un autre appareil. Utilisez systèm de ventilation "L" ou "PL" diamètre 76mm ou 102mm Conforms to ASTM Std E1509-12. Certified to ULC S627-00. Room Heating Pellet BurningType, (UM) 84-HUD FOR USE ONLY WITH PELLETIZED WOOD FUEL. Do not use any other type of fuel. Input Rating: 52,500 Btu's/hr. Electrical Rating:115 VAC, 60 Hz, Start 2.9 Amps, Run 2.45 Amps. Route power cord away from unit. Do not route cord under or in front of appliance. Do not obstruct the space beneath the heater. DANGER: Risk of electrical shock. Disconnect power supply before servicing. Replace glass only with 5mm ceramic. To start, turn dial control to desired setting and set thermostat above room temperature, the stove will light automatically. To shutdown, turn dial control to OFF or set thermostat below room temperature. For further instruction refer to owner's manual. Keep viewing doors tightly closed during operation. Keep viewing and ash removal doors tightly closed during operation. Conforme à la norme ASTM E1509-12 Std. Certifié à la norme ULC S627-00. Room Heating Pellet Burning Type, (UM) 84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS. N’utiliser aucun autre genre de combustible. Puissance de Rendement: 52,500 Btu's/hr. Puissance Électrique: 115 VAC, 60 Hz, Début 2.9 Amps, Courir 2.45 Amps, Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil. Ne pas bloquer l’espace au dessous de l’appareil. DANGER: Il y a risque de décharge électrique. Déconnectez le fil électrique de la prise de contact avant le service. Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur. Pour commencer, tournez la molette de réglage à la température désirée et réglez le thermostat au-dessus de la température ambiante, le poêle s'allumera automatiquement. Pour éteindre, tournez la molette de réglage sur OFF ou réglez le thermostat dessous de la température ambiante. Pour des instructions supplémentaires, référez vous au manuel du propriétaire. Gardez la porte d'ouverture et la porte des cendres fermées hermétiquement durant l'opération. A B C D D MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS ESPACES LIBRES MINIMUM DES MATÉRIAUX A Back Wall / Mur Arrière 2 in [51 mm] B Side Wall / Mur De Côté 6 in [152 mm] C “L” or “PL” Pipe to Back Wall / “L” ou “PL” Un Tuyau Mur Arrière 1 in [25 mm] D Side Wall / Mur De Côté 2 in [51 mm] FLOOR PROTECTION / PROTECTION DU SOL Floor protector must be non-combustible material, extending beneath heater and to the front/sides/rear as indicated. Measure front distance (I) from the surface of the glass door. Le poêle doit être placé sur une assise non combustible s’étendant tout autour de lui, comme les schémas l’indiquent. Mesurez la distance du devant (I) de la surface de la porte vitrée. *Non-combustible floor protection must extend 2 inches (51mm) beneath the flue pipe when installed with horizontal venting or under the Top Vent Adapter with vertical installation. RECOMMENDED IN USA; REQUIRED IN CANADA. *Un protecteur incombustible de plancher doit s'étendre 2 inches (51mm) sous le conduit de cheminée pour une installation de ventilation horizontale ou sous un adapteur de ventilation de dessus pour une installation verticale. RECOMMANDÉ AUX ÉTATS-UNIS; NÉCESSAIRE AU CANADA. USA G = 2 in H* = 2 in I = 6 in CANADA G = 200 mm H* = 200 mm I = 450 mm G H I G 7080-133 U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply with July 1990 particulate emission standards. DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE Made in U.S.A. of US and imported parts. Fabriqué aux États-Unis-d’Amérique par des pièces d’origine américaine et pièces importées. 2013 2014 2015 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 1445 North Highway, Colville, WA 99114 www.quadrafire.com Manufactured by:Fabriqué par Owners Manual Install Manual O-T L Tested and Listed by Portland Oregon USA OMNI-Test Laboratories, Inc. C US Report: 061-S-83-2 S A M P L E A. Congratulations Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durability, and performance. This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs. Our Research and Development facility then employs the world’s most advanced technology to achieve the optimum opera- tion of our stoves, inserts and fi replaces. And yet we are old-fashioned when it comes to craftsmanship. Each unit is meticulously fabricated and gold and nickel surfaces are hand-fi nished for lasting beauty and enjoyment. Our pledge to quality is completed as each model undergoes a quality control inspection. We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing Quadra-Fire. NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction and Welcome to the Quadra-Fire Family!

October 27, 2014

7080-132D 3 MT. VERNON E2 TABLE OF CONTENTS Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. • NOTICE: Indicates practices which may cause damage to the appliance or to property. A. Congratulations ........................................................2 B. Sample of Serial Number / Safety Label ..................2 C. Warranty Policy ........................................................4 D. Quick Start Guide .....................................................6 1 Listing and Code Approvals .............7 A. Appliance Certifi cation .............................................7 B. BTU & Effi ciency Specifi cations ..............................7 C. Glass Specifi cations ................................................7 D. Electrical Rating ......................................................7 E. Mobile Home Approved ........................................... 7 2 Operating Instructions ......................8 A. Fire Safety ................................................................8 B. Non-Combustible Materials .....................................8 C. Combustible Materials .............................................8 D. Fuel Material and Fuel Storage ...............................8 E. Before Your First Fire ..............................................9 F. Filling the Hopper ......................................................9 G. User Dial Control ....................................................9 H. Normal Startup Sequence ........................................9 I. Firepot Purge ............................................................9 J. Shutdown ..................................................................9 K. Fire Characteristics .................................................10 L. Your Pellet Appliance’s General Operating Parts ....10 M. LED Color Coding Chart and Explanation ..............11 N. Restarting the Appliance ..........................................12 O. Clear Space ............................................................12 P. Trim Adjustment .......................................................12 Q. Remote Thermostat .................................................12 R. Bypassing the Remote System (Manual Mode) .......13 S. Frequently Asked Questions ...................................14 3 Maintenance and Service ................15 A. Proper Shutdown Procedure ....................................15 B. Quick Reference Maintenance Chart ......................15 C. General Maintenance and Cleaning .......................16 D. Soot or Creosote Fire Awareness ............................19 E. High Ash Fuel Content Maintenance ........................20 F. Baffl e Removal .......................................................20 G. Glass Replacement ...............................................20 H. Convection Blower Replacement ...........................21 I . Combustion/Exhaust Blower Replacement .............22 4 Troubleshooting Guide ....................23 5 Reference Materials .........................27 A. Component Functions .............................................27 B. Exploded Drawings ..................................................28 C. Parts List ..................................................................29

October 27, 2014

MT. VERNON E2 Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer. WARRANTY COVERAGE: HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance will be free from defects in materials and workmanship at the time of manufacture. After installation, if covered compo- nents manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period, HHT will, at its option, repair or replace the covered components. HHT, at its own discretion, may fully discharge all of its obligations under such warranties by replacing the product itself or refunding the verified purchase price of the product itself. The maximum amount recoverable under this warranty is limited to the purchase price of the product. This warranty is subject to conditions, exclusions and limitations as described below. WARRANTY PERIOD: Warranty coverage begins on the date of original purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent, authorized HHT dealer/ distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of product shipment from HHT, regardless of the installation or occupancy date. The warranty period for parts and labor for covered components is produced in the following table. The term “Limited Lifetime” in the table below is defined as: 20 years from the beginning date of warranty coverage for gas appliances, and 10 years from the beginning date of warranty coverage for wood, pellet, and coal appliances. These time periods reflect the minimum expected useful lives of the designated components under normal operating conditions. See conditions, exclusions, and limitations on next page. Parts Labor Gas Wood Pellet EPA Wood Coal Electric Venting X X X X X X X All parts and material except as covered by Conditions, Exclusions, and Limitations listed X X X Igniters, electronic components, and glass X X X X X Factory-installed blowers X Molded refractory panels X Firepots and burnpots 5 years 1 year X X Castings and baffles 7 years 3 years X X X Manifold tubes, HHT chimney and termination 10 years 1 year X Burners, logs and refractory Limited Lifetime 3 years X X X X X Firebox and heat exchanger X X X X X X X All replacement parts beyond warranty period Warranty Period HHT Manufactured Appliances and Venting 1 Year Components Covered 3 years 2 years 90 Days C. Warranty Policy

October 27, 2014

7080-132D 5 MT. VERNON E2 WARRANTY CONDITIONS:                                                                                      !                     "                          "                                  This warranty is void if:       #           !  !        $ #     !     !    !       ! !  "            %                                      !    !            LIMITATIONS OF LIABILITY:    '*   '      !      !*   !    !     !      !   !   !             +           8     *        +    !               ;        !     <=<>$ <<=@$KN@<88U@@?<8$<@?<U@@?Q 8><\R@<88<\

October 27, 2014

MT. VERNON E2 D. Quick Start Guide Run Set Up Prime 1. Empty Firebox 2. Add pellets and close lid 3. Turn DIAL to OFF 4. Plug in the appliance • Exhaust blower will run for about 45 Seconds (wait for it to stop before priming) • Green light will start fl ashing 5. Put batteries in the Touch Screen Remote Thermostat 6. Press the MODE button on the remote thermostat until ON appears in the upperleft corner • You should hear an audible tone from the appliance 1. After the exhaust blower has stopped; quickly turn the dial from OFF to HI two times • The LIGHT will turn solid green and pellets will feed. Wait for 2 minutes • If the LIGHT did not turn solid green: - Turn dial back to OFF - Unplug appliance, plug it back in and repeat Priming is only needed for fi rst fi re or starting fi re on empty hopper. H E A T S E T T I N G H E A T S E T T I N G O F F HI LO H E A T S E T T I N G H E A T S E T T I N G O F F HI LO H E A T S E T T I N G H E A T S E T T I N G O F F HI LO 2. Choose Setting: LO – HI* Green LIGHT will be- gin fl ashing and stove will start It may take as long as 10 minutes to achieve a fi re in the fi repot. Turning the knob or thermostat to off during this time will inter- rupt the startup process. *For fi rst fi re, HHT recommends running on HI for fi rst 30 minutes 0 - 1 - 2 - 3 - 4 + 1 + 2 + 3 + 4 A L A R M O N H E A T S E T T I N G H E A T S E T T I N G O F F HI LO MODE/SET 1. Choose Mode: ON or THERM -pick “Temp” Touch Screen Remote Thermostat Control Panel Light Dial Trim

October 27, 2014

7080-132D 7 MT. VERNON E2 *BTU will vary, depending on the type of fuel you use in your appliance. Consult your Quadra-Fire dealer for best results. C. Glass Specifi cations This stove is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass. D. Electrical Rating 115 VAC, 60 Hz, Start 2.9 Amps, Run 2.45 Amps The Quadra-Fire Mt. Vernon E2 Pellet Stove meets the U.S. Environmental Protection Agency’s 1990 particulate emission standards. Model Mt. Vernon Pellet Stove E2 Laboratory OMNI Test Laboratories, Inc. Report No. 061-S-83-2 Type Solid Fuel Room Heater, Pellet and Shelled Corn Fuel Burning Type Standard ASTM E1509-12, ULC S627-00 and (UM) 84-HUD, Mobile Home Approved. FCC Complies with Part 15 of FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. EPA Certifi ed: 1.7 grams per hour EPA Certifi cation Number and Date: Number: 926 Issued: 2014 Effi ciency: 86.5% BTU Input EPA: 18,000 to 52,500 BTU Output: EPA: 13,800 to 37,600 Vent Size: 3” or 4” Type ‘L’ or ‘PL’ Fuel: Wood Pellets & Shelled Corn • Installation and use of any damaged appliance. • Modifi cation of the appliance. • Installation other than as instructed by Hearth & Home Technologies. • Installation and/or use of any component part not approved by Hearth & Home Technologies. • Operating appliance without fully assembling all components. • Operating appliance without legs attached (if supplied with unit). • Do NOT Overfi re - If appliance or chimney connector glows, you are overfi ring. Any such action that may cause a fi re hazard. 1 Listing and Code Approvals A. Appliance Certifi cation NOTE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its products, their specifi cations and/or price without notice. NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the ASTM E1059-12, ULC S627-00, (UM) 84-HUD and ULC/ORD- C-1482. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualifi ed installer, service agency or your dealer. Quadra-Fire is a registered trademark of Hearth & Home Technologies. WARNING Fire Risk. Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions: B. BTU & Effi ciency Specifi cations E. Mobile Home Approved • This appliance is approved for mobile home installa- tions when not installed in a sleeping room and when an outside combustion air inlet is provided. • The structural integrity of the mobile home fl oor, ceil- ing, and walls must be maintained. • The appliance must be properly grounded to the frame of the mobile home and use only Listed pellet vent Class “L” or “PL” connector pipe. • Outside Air Kit (OAK-3) must be installed in a mobile home installation.

October 27, 2014

MT. VERNON E2 User Guide 2 Operating Instructions A. Fire Safety To provide reasonable fi re safety, the following should be given serious consideration: • Install at least one smoke detector on each fl oor of your home. • Install at least one carbon monoxide detector on each fl oor of your home. • Locate smoke detector away from the heating appliance and close to the sleeping areas. • Follow the smoke detector manufacturer’s placement and installation instructions and maintain regularly. • Follow the carbon monoxide manufacturer’s placement and installation instructions and maintain regularly. • Conveniently locate a Class A fi re extinguisher to contend with small fi res. • In the event of a hopper fi re: • Evacuate the house immediately. • Notify fi re department. B. Non-Combustible Materials Material which will not ignite and burn, composed of any combination of the following: - Steel - Plaster - Glass - Tile - Brick - Iron - Slate - Concrete Materials reported as passing ASTM E 136, Standard Test Method for Behavior of Metals, in a Vertical Tube Furnace of 750° C. C. Combustible Materials Material made of/or surfaced with any of the following materials: - Compressed Paper - Wood - Plywood/OSB - Sheet Rock (drywall) - Plastic - Plant Fibers Any material that can ignite and burn: fl ame proofed or not, plastered or un-plastered. D. Fuel Material and Fuel Storage Pellet fuel quality can greatly fl uctuate. We recommend that you buy fuel in multi-ton lots whenever possible. However, we do recommend trying various brands before purchasing multi-ton lots to ensure your satisfaction. Fuel Material • Made from sawdust or wood by-products • Depending on the source material it may have a high or low ash content. Higher Ash Content Material • Hardwoods with a high mineral content • Fuel that contains bark • Standard grade pellets or high ash pellets Lower Ash Content Material • Most softwoods • Fuels with low mineral content • Most premium grade pellets Corn • A 2:1 mix of pellets to corn is approved, but may re- quire the fi repot to be cleaned more frequently. • When using a pellet/corn fuel mixture, it is recommend- ed that the trim adjustment is set to -4 (see pg. 12). • Corn must be free of debris. Never burn corn straight from the fi eld. It will clog the auger mechanism. • Corn with excessive grain dust must be screened by sifting with 3/16 (4.76mm) inch mesh screening • Do not use corn that contains additives such as oils or means or has been chemically treated with pesticides. It will void your warranty and destroy the exhaust sys- tem. Clinkers Minerals and other non-combustible materials such as sand will turn into a hard, glass-like substance called a clinker when heated in the fi repot. Trees from different areas will vary in mineral content. That is why some fuels produce more clinkers than others. Moisture Always burn dry fuel. Burning fuel with high moisture content takes heat from the fuel and tends to cool the appliance, robbing heat from your home. Damp pellet fuel can clog the feed system. Size • Pellets are either 1/4 inch or 5/16 inch (6-8mm) in diameter • Length should be no more that 1-1/2 inches (38mm) • Pellet lengths can vary from lot to lot from the same manufacturer • Due to length variations, the feed rate may need adjusting occasionally Performance • Higher ash content requires the fi repot and the ash drawer to be emptied more frequently • Hardwoods require more air to burn properly • Premium wood pellets produce the highest heat output Fire Risk. WARNING • Do not operate appliance before reading and understanding operating instructions. • Failure to operate appliance properly may cause a house fi re.

October 27, 2014

7080-132D 9 MT. VERNON E2 Figure 9.1 HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. CAUTION • Burning pellets longer than 1-1/2 inches (38mm) can cause an inconsistent fuel feed rate and/or missed ignitions or feed jams. Storage • Wood pellets should be left in their original sealed bag until using to prevent moisture absorption • Do not store any pellet fuel within the clearance requirements or in an area that would hinder routine cleaning and maintenance E. Before Your First Fire 1. First, make sure your appliance has been properly installed and that all safety requirements have been met. Pay particular attention to the fi re protection and venting. 2. Double check that the fi rebox is empty and the fi repot fl oor is fully closed. 3. Close and latch the door. F. Filling the Hopper Open the hopper lid by lifting the handle. Fill the hopper with fuel. Close the hopper lid. The unit will not feed with the hopper lid open and the fi re will go out. H E A T S E T T I N G H E A T S E T T I N G O F F HI LO G. User Dial Control The appliance has one dial control located on the side of the unit (behind a drop door) used for changing the heat setting and restarting the appliance. There are fi ve heat settings on this dial ranging to include: LOW, MED-LOW, MED, MED-HIGH, and HIGH. Figure 9.1 Turn the dial control to the desired heat setting and turn the appliance ON and OFF using the remote thermostat. H. Normal Startup Sequence The unit will go into the ignition sequence followed by a start up sequence (the green LED will fl ash rapidly). The ignition sequence involves the exhaust blower and igniter turning on, and the feed motor running in two stages. The fi rst stage involves the feed motor running continu ously for about a minute to preload pellets into the fi repot. In the second stage, the feed motor will begin cycling on and off. When the pellets are warming - on the verge of igniting - it is not uncommon for the fi rebox to fi ll with smoke. Once ignition happens, the smoke should quickly disap- pear. During this stage, as well as any part during the burn process, the front door should not be opened. This startup cycle continues until the unit senses ignition by a rise in the exhaust temperature or the unit times out. Fol- lowing the ignition cycle the unit continues to feed pellets to build up the fi re. After warming up, the convection blower will begin to blow warm air into the room. As the appliance increases heat the blower will increase its output. I. Firepot Purge Purpose: To help remove debris from the fi repot and help the unit burn as effi cient as possible. The frequency of the purge cycle is once every 50 minutes while the unit is burning. During the fi repot purge, the feed is reduced to the lowest setting and the exhaust blower ramps up to a very high setting. The purge cycle lasts 99 seconds. The purge cycle does not replace daily cleaning. J. Shutdown To shut the appliance down, turn the dial control to OFF or turn the thermostat to OFF. During the shutdown pro- cess, the light will fl ash green rapidly just like the ignition sequence. Unlike the fi repot purge, during shutdown existing fuel in the fi repot will continue to burn without the feed motor run- ning; but, the exhaust and convection blowers will remain on until the exhaust has cooled. NOTE: If maintenance or daily cleaning is going to be conducted immediately following a shutdown, please use caution as components especially those inside the fi rebox may still be hot. Due to safety precautions: • If the dial control is turned to OFF and back on (even if by mistake) the unit will go through the shutdown sequence before restarting. • Additionally, if the remote thermostat is set to “OFF” or “THERMOFF” during operation the appliance will go through a shutdown sequence before restarting. NOTE: UNIT CAN USE 2:1 PELLET/CORN MIXTURE. We recommend the use of a 2:1 pellet/corn mixture. The only change in operation is that the feed rate may require a slight adjustment.

October 27, 2014

MT. VERNON E2 K. Fire Characteristics The overall height of the fl ame will vary throughout the burn for a couple of reasons: 1) The fl ame will vary based on type of fuel or batch of fuel. 2) The unit adjusts the burn rate according to the dial set- ting – the further the dial is rotated clockwise the higher the fl ame and consequently, heat output. 3) General maintenance and cleaning. Infrequent or poor general maintenance will result in poorer performance. Indicators for additional maintenance activities include:  lazy fl ame  black-sooted glass  pellets not igniting  excess pellets fall ing to the side of the fi repot. 4) See trim adjustment section for additional information. Odors and vapors released during initial operation. • Curing of high temperature paint. • Open windows for air circulation. Odors may be irritating to sensitive individuals. CAUTION WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down. Hot glass will cause burns. • DO NOT touch glass until it is cooled. • NEVER allow children to touch glass. • Keep children away. • CAREFULLY SUPERVISE children in same room as appliance. • Alert children and adults to hazards of high temperatures. High temperatures may ignite clothing or other fl ammable materials. • Keep clothing, furniture, draperies and other fl ammable materials away. NOTICE: If you expect children to come into contact with this appliance, we recommend a barrier such as a decora- tive screen. See your retailer for suggestions. L. Your Pellet Appliance’s General Operating Parts Ash Dump Lever Baffle Latch Firepot Baffle Wireless Reciever Dial Control Hopper Switch

October 27, 2014

7080-132D 11 MT. VERNON E2 LED Color No. of Flashes between pauses Description Notes Green Steady ON while priming feed tube (max time 2 min utes) Feed Motor is running continuously. (priming the feed tube) When priming the feed system and fi lling the fi repot, DO NOT OVERFILL FIREPOT FOR IGNITION. The unit will automatically go into start up following the prime function. Green 1x every 2 seconds Unit is on standby To start appliance, follow start up sequence. Green Blinks Continu- ously Appliance is in the start up/ignition sequence or in shutdown. During shut down, the blowers will shut off when the exhaust temperature has cooled. Green 1X Stage 1: Low heat BTU Range: 1,8653 - 19,694 Average: 19,054 Green 2X Stage 2: Med-Low heat BTU Range: 22,102 - 23,506 Average: 22,735 Green 3X Stage 3: Med heat BTU Range: 30,778 - 32,680 Average: 31,603 Green 4X Stage 4: Med-Hi heat BTU Range: 38,576 - 42,914 Average: 40,665 Green 5X Stage 5: Hi heat BTU Range: 49,830 - 52,460 Average: 51,528 Red 1X Empty Hopper Alarm This alarm is caused by the fi re going out from lack of fuel. Reset by turning to “OFF” then turn dial to desired setting. Red 2X Exhaust Probe Alarm Failed component error. See troubleshoot ing section for more information. Red 4X Missed Ignition There are a total of 2 tries per ignition sequence. If after 2 tries there is no rise in exhaust temperature this error will occur. See the troubleshooting section for addi tional information. Red 6X Encoder Alarm Failed Component Error: Exhaust Speed Sensor. See troubleshooting guide for more information Red 8X Exhaust Over Temperature Alarm See troubleshooting guide for more information. M. LED Color Coding Chart and Explanation The number of fl ashes between pauses is per one second unless otherwise indicated. WARNING Fire Risk Do NOT operate appliance: • With appliance door open. • Firepot fl oor open. Do NOT store fuel: • Closer than required clearances to combustibles to appli- ance • Within space required for loading or ash removal.

October 27, 2014

MT. VERNON E2 N. Restarting the Appliance Restart Process 1. When the unit has run out of fuel and the “empty hopper” error code illuminates, add pellet fuel to the hopper. 2. Dump the ashes and clinkers built up in the fi repot by pulling the ash dump removal handle out several times. Make sure clinkers have dropped into the ash pan then return the handle to fully closed position. 3. Turn the dial control to OFF and then up to high 2X to prime. 4. After seeing pellets drop then turn to desired setting to reset the appliance control system. The appliance will then being its startup sequence. Restarting After a Power Failure 1. For an electrical disruption the appliance will start on its own without need for priming - providing the control system is asking for heat. 2. The appliance will always go through a normal shut- down sequence before restarting. Remote Power Requirements • The remote receiver power is maintained through appli- ance power. • The remote thermostat uses four AAA batteries. O. Clear Space NOTICE: Clearances may only be reduced by means ap proved by the regulatory authority having jurisdiction. Mantel: Avoid placing candles and other heat-sensitive ob- jects on mantel or hearth. Heat may damage these objects. P. Trim Adjustment The small dial located below the main dial control is used to adjust the amount of combustion air for the fi re. You may need to adjust the combustion air to the fi re for: • Elevation • Venting/Installation Confi gurations • Fuel Quality • Fuel Type If your fi re is too large, lazy, or producing black soot, you need MORE air. To increase the amount of combustion air, rotate the dial clockwise one level at a time and allow 15 minutes for stabilization prior to making another adjust- ment. If the fi re continues to appear too rich turn the trim dial setting counterclockwise to the negative numbers to decrease fuel fl ow. Figure 12.1 If the fi re is too small or occasionally goes out when there are pellets in the hopper, the unit may have too much air. To decrease the amount of combustion air, rotate the trim dial towards zero one level at a time and allow 15 min utes for stabilization prior to making another adjustment. Q. Remote Thermostat Learning Remote Thermostat to Receiver 1. With receiver and remote thermostat powered, set the receiver to “REMOTE” and remote thermostat to “ON”. 2. Push receiver “LEARN” button momentarily - an audi- ble tone should emit from the receiver. 3. Push the remote thermostat “MODE” button until “OFF” shows on the screen - an audible sound should emit from the receiver. 4. To check whether the receiver is “learned” push “MODE” on the remote thermostat several times - an audible sound should be heard from the receiver. 5. If no sound is heard repeat the process. Remote Thermostat: Instructions 1. The remote thermostat activates an internal “on-off” switch in the receiver (located in the appli ance). 2. If the remote thermostat setting is higher than its local surrounding temperature it will signal the receiver to turn ON; if the user setting is equal to- or less than the local surrounding temperature then the remote thermo- stat will signal the receiver to turn OFF. Remote Thermostat: Setting Clock 1. Push “TIMER” on the screen of for more than two sec- onds. The hour digit(s) should begin to fl ash. 2. Press the UP or DOWN buttons until the desired hour is displayed (notice the AM - PM). 3. After setting the desired hour, press and release “TIMER” again and the minute digits will begin fl ashing. 4. Press the UP or DOWN buttons until the desired min- utes are displayed. 5. Press “MODE” or “TIMER” buttons again for more than two seconds then release. 6. The minute digits will stop fl ashing, the clock has been successfully set. Remote Thermostat: Countdown Timer Function 1. Change the mode to “ON” (or “THERMON” with the set point higher than the room temperature), push “TIMER” on the screen. 2. 0:15 should appear on the screen. 3. Pressing the up and down arrows will allow for increase and decrease of the timer (15-minute increments up to 1-hour; 30 –minute increments after 1-hour). 4. When the timer expires the remote should send an “OFF” signal to the appliance. Figure 12.1 More Air More Air & Less Fuel

October 27, 2014

7080-132D 13 MT. VERNON E2 Remote Thermostat: Fahrenheit / Celsius 1. Temperatures will show either °F or °C displayed on the screen. 2. Press both “UP” and “DOWN” arrow keys simultane- ously. The display should change from Fahrenheit to Celsius or vice-versa. Remote Thermostat: Swing 1. The swing temperature will allow over-target of the set point temperatures set while in “THERMO” mode. Example, if the set point temperature is 70°F and swing is ±2° the appliance will not go into a shutdown until it reaches 72°F. Likewise, the appliance will not startup unless it is below 68°F. 2. To change the temperature “SWING” setting (1°-3°), press the TIMER and DOWN buttons simultaneously to display the current “SWING” setting in the SET TEMP frame. 3. The letter “S” will display in the ROOM TEMP frame on the screen. 4. Press the UP or DOWN button to change the tempera- ture differential (from 1º to 3º). 5. To store the “swing number press the MODE/SET button or allow 15 seconds to lapse, and the new “swing number’ will be programmed. 6. To verify that the swing is properly set, and with the appliance dial control set to “OFF” & remote thermostat set to “THERMO”, raise and lower the temperature above and below the room temperature to identify its response. This should change from THERMON to OFFTHERMO. Remote Thermostat: Child Lockout feature 1. To activate the “LOCK-OUT” feature, press and hold the UP button and touch the word TIMER on the screen of the transmitter together, for 5 seconds. The lock icon will appear on the screen. 2. To disengage the “LOCK-OUT”, press and hold the UP button and touch the word TIMER on the screen together for 5 seconds or more, and the lock icon will disappear from the screen. The transmitter will return to its normal operating condition. Note: If the appliance is already operating in the ON or THERMO MODES, engaging the “LOCK-OUT” will not cancel the operating MODE. Engaging the “LOCK-OUT” prevents only the manual operation of the TRANSMITTER. If in the auto modes, the THERMO operation will continue to operate normally. To completely “LOCK-OUT” the opera- tion of the TRANSMITTER’S operating signals; the trans- mitter’s MODE must be set to OFF. Remote Thermostat: Signal 1. The remote thermostat sends a signal to the receiver every 15 minutes verifying the transmitter is still in range. 2. If the remote thermostat falls out of signal range for over 2 hours or has no battery power the receiver will emit a communication Safety Error Code consisting of a series of rapid “beeps” for a period of 10 seconds and the appliance will shut down. After 10 seconds of rapid beeping, the receiver will continue to emit a single “beep” every 4 seconds until the remote thermostat MODE button is pressed, resetting the receiver. Note: Unless damaged or remote component is replaced the receiver will maintain its communication link to its trans- mitter for many years. Remote Trouble Shooting 1. Make sure the remote thermostat’s batteries are prop- erly installed. 2. Check to make sure the thermostat is communicating with the receiver (an audible sound from the receiver should emit when changing from “OFF” to “ON”). 3. If the receiver does not beep when changing from OFF to ON, you will need to “LEARN” the receiver to the remote thermostat. (See Learning the remote thermo- stat to receiver section). 4. Make sure the remote thermostat is within the 15 to 20-foot range of the receiver. R. Bypassing the Remote System (Manual Mode) 1. If the remote thermostat is lost, broken, or loses its power the appliance can be operated in manual mode. 2. Locate the three-way switch on the receiver. Figure 14.1 3. Placing the receiver three-way switch to “ON” will bypass the remote thermostat function, rendering the appliance dial control as its exclusive control. 4. The appliance will not run when the switch is set to “OFF”. Location of the Remote Receiver: The receiver face can be seen on the lower RH side toward the back [without removing the side panel]. Note: Placing the receiver three-way switch in the “REMOTE”, or center-most position empowers the remote system. Figure 14.1

October 27, 2014

MT. VERNON E2 S. Frequently Asked Questions What causes my glass to become dirty? If the glass has white ash build up it is normal and the glass should be cleaned. If it is a black soot build up airfl ow through the unit may be restricted. The most often cause is overdue maintenance and cleaning. See “Maintaining and Servicing Appliance” and/or make adjustments to the trim control. How can I get more heat out of the appliance? The most often cause of diminished heat output is overdue maintenance and cleaning. See “Maintaining and Servicing Appliance”. What should I do if I smell smoke or there is ash/soot coming from the appliance? While there will always be some smoke smell from wood burning appliances (including pellet) you should investigate all venting to make sure it is sealed properly. Most vent ing requires silicone to seal the seams. In addition most homes are built very tight today and with exhaust systems can create negative pressure in the home. See “Negative Pressure” under “Getting Started” in the owner’s manual if you have checked the venting but still have smoke coming from the appliance. For ash or soot check the above and the exhaust blower housing and seals. Why would my appliance run fi ne last winter but not start this fall? It is possible that the stove was not properly prepared for the Non-burn season (see troubleshooting section). Is there a place to lubricate the blowers to quiet them down? No. The most often cause of noisy blowers is from the impellers becoming dirty over time. See maintenance and service section for maintaining and servicing. What is the metal object with the bend in it that came inside the plastic bag? It is a clean-out tool used to help clean the fi repot and remove any jams in the rare event they occur in the feed tube. Why is there a black residue building up on the outside of my home? Wind can cause this to happen. If the appliance is oper- ating correctly very little soot should ever exit the termina- tion cap. Check to be sure the venting is installed per the owner’s manual and local codes. Do I need an outside air kit? Outside air is required for mobile home installs and in some jurisdictions. Refer to “Listing & Code Approvals”,“ Mobile Home Installation” and “ Appliance Set-up”. Also refer to local building codes. I am seeing sparks coming out of my pipe (termination cap) outside is this safe? This is normal. As long as clearances to combustibles were followed this is safe. I have no power to anything. Does this unit have a cir- cuit breaker or fuse or a reset button? This unit has one fuse on the control board and a resettable snap disc mounted to the feed tube. If the appliance over- heats then the snap disc can be reset; if the fuse is blown the control board must be replaced. Can I burn corn in my unit? Yes, a 2:1 mix of pellets to corn is approved, but may require the fi repot to be cleaned more frequently. When using a pellet/corn fuel mixture, it is recommended that the trim adjustment is set to -4 (see pg. 12). Where is the serial # located on my unit? Freestanding - the serial number is located on the back of the stove. No pellets are dropping in my fi repot. See troubleshooting guide. Contact your dealer for additional information regarding operation and troubleshooting. Visit www.quadrafi re.com to locate a dealer.

October 27, 2014

7080-132D 15 MT. VERNON E2 3 Maintenance and Service B. Quick Reference Maintenance Chart NOTICE: These are recommendations. When burning high ash content pellet fuel or a corn/pellet mix you may need to clean the fi repot several times a day. Clean the stove and fi repot more frequently if you encounter heavy build-up of ash at the recommended interval or you see soot coming from the vent. Not properly cleaning your appliance on a regular basis will void your warranty. Shock and Smoke Hazard • Smoke spillage into room can occur if appliance is not cool before unplugging. • Risk of shock if appliance not unplugged before servicing appliance. CAUTION Follow the detailed instructions found in this section for each step listed as referenced in the chart below. When properly maintained, your appliance will give you many years of trouble-free service. Contact your dealer to answer questions regarding proper operation, troubleshoot- ing and service for your appliance. Visit www.quadrafi re. com to locate a dealer. We recommend annual service by a qualifi ed dealer. A. Proper Shutdown Procedure Turn dial control to OFF, let appliance completely cool and exhaust blower must be off. After cooling unplug appliance before servicing. Cleaning or Inspection Frequency Daily Weekly Monthly Yearly Firepot As needed OR X Ash Removal from Firebox About 5 bags of fuel depend- ing on ash build-up OR X Glass When clear view of fi repot becomes obscure OR X Hopper Every ton of fuel (50 bags) OR X Exhaust Path, Drop Tube and Behind Baffl es Every ton of fuel (50 bags) or more frequently OR X Door Handle & Gasket Inspection Prior to heating season OR X Blower, Convection Every ton of fuel or more fre- quently depending on perfor- mance OR X Blower, Exhaust Every ton of fuel or more fre- quently depending on perfor- mance OR X Firebox - Prepare for Non-Burn Season At end of heating season OR X Venting System Every 3 tons of fuel or more frequently depending on per- formance OR X

October 27, 2014

MT. VERNON E2 Figure 16.1 - Firepot with large clinker Clinker Figure 16.2 C. General Maintenance and Cleaning 1. Cleaning Firepot using Lever • Frequency: Daily or as needed* • By: Homeowner *When burning high ash content pellet fuel or a pellet/corn mix you may need to clean the fi repot several times a day. a. Be sure the appliance is allowed to cool. b. Open cast face of appliance c. Pull fi repot fl oor cleaning lever two times until the ash falls into the ashpan below. Figure 16.2 d. It may be necessary to use your fi repot clean-out tool to chip away material that has built up on the sides of the fi repot and to push out any clinkers. Figure 16.1 e. Larger clinkers may have to be removed from the top of the fi repot. f. If the clinker adheres to the sides of the fi repot, you will need to manually clean the fi repot. The fi repot fl oor plate must be fully closed when fi nished. 2. Cleaning Ash Pan • Frequency: Weekly or every 3-5 bags • By: Homeowner a. Locate the ash pan underneath the fi repot. b. Slide the ash pan straight out. c. Empty into a non-combustible container and re-install ash pan. d. When replacing ash pan push it back until it catches on the 2 side latches. Clinkers fi lling the ash pan will have to be cleaned out more often than ash. Ash Disposal: Ashes should be placed in a steel container with a tight- fi tting lid. The container of ashes should be moved outdoors immediately and placed on a non-combustible fl oor or on the ground, well away from combustible materials, pending fi nal disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled. Other waste shall not be placed in this container. 3. Ash Removal from Firebox • Frequency: Weekly or more frequently depending on ash build-up • By: Homeowner a. Be sure the appliance is allowed to cool. b. There must not be any hot ashes in the fi rebox during cleaning. c. Frequent cleaning of the ash in the fi rebox with a vacuum cleaner will help slow down the build-up of ash in the exhaust blower and vent system. RISK OF FIRE Keep combustible materials, gasoline and other fl am- mable vapors and liquids clear of appliance. • Do NOT store fl ammable materials in the appli- ance’s vicinity. • Do NOT use gasoline, lantern fuel, kerosene, charcoal lighter fl uid or similar liquids to start or “freshen up” a fi re in this heater. Keep all such liquids well away from the heater while it is in use as combustible materials may ignite. WARNING 4. Cleaning Heat Exchanger & Drop Tube • Frequency: Monthly or every ton of fuel (50 bags). • By: Homeowner NOTE: Heavy duty vacuum cleaners may be obtained, spe- cifi cally designed for solid fuel appliance cleaning.

October 27, 2014

7080-132D 17 MT. VERNON E2 Figure 17.2 - Example of a dirty heat exchanger Figure 17.3 Shop Vacuum and Micro Cleaning Kit examples - items that can be purchased at local hardware stores. Figure 17.4 Figure 17.1 Exhaust exits must be thoroughly cleaned. Each exit is approximately 4 inches wide, 1 inch across, and 3 inches deep * Can be purchased at your local hardware store. Hopper Fire Risk! For trouble free use of your pellet appliance you must perform cleaning as called for in these in- structions. Not doing so will result in: • Poor operating performance • Smoke spillage into the home • Overheating of components Not properly cleaning your appliance on a regular basis will void your warranty. WARNING Cleaning Heat Exchanger & Drop Tube (cont.) Tools Needed: A Shop Vacuum and generic micro cleaning kit; fl at head screwdriver; bottle brush, ½” ID hose. a. It is necessary to remove the baffl e to gain access to the heat exchanger (fi gure 17.2). Follow instructions for baffl e removal on page 20, fi gure 20.2. b. Vacuum the ash from the heat exchanger with an upholstery brush to remove the majority of the ash. Be sure to vacuum the back of the baffl e also. Inspect the drop tube and remove any residue build-up in the drop tube. Figure 17.3 c. Assemble the crevice tool from the micro cleaning kit to attach to a Shop Vac. Figure 17.4 d. Use the crevice tool to fi nish cleaning the heat exchanger fi ns. It is critical that the 2 exhaust exits at the back of the fi rebox fl oor (left and right) be thoroughly cleaned. Figure 17.2 There are several ways this can be done: 1. Use the crevice tool. 2. Attach a hose 1/2 inch (12.7mm) inside diameter and approximately 2 feet (607mm) in length to your vacuum hose. 3. Use a bottle brush and push the ash down to the bottom. Remove the combustion (exhaust) blower and then vacuum out the ash.

October 27, 2014

MT. VERNON E2 Figure 18.1 Ash Dump Lever Handle glass assembly with care. When cleaning glass door: • Avoid striking, scratching or slamming glass. CAUTION • Do NOT clean glass when hot. • Do NOT use abrasive cleaners. • Use a hard water deposit glass cleaner on white fi lm. Refer to maintenance instructions. Handle glass doors with care. • Inspect the gasket to ensure it is undamaged. • Do NOT strike, slam or scratch glass. • Do NOT operate appliance with glass door removed, cracked, broken or scratched. WARNING 6. Cleaning the Hopper • Frequency: See chart on page 15 • By: Homeowner a. Be sure the appliance is allowed to cool. b. After burning approximately 1 ton of fuel you will need to clean the hopper to prevent sawdust and/or fi nes build-up. c. A combination of sawdust/fi nes and pellets on the auger reduces the amount of fuel supply to the fi repot. d. This can result in nuisance shut downs and mis-starts •. Empty the hopper of any remaining pellets. •. Vacuum the hopper and feed tube. 7. Cleaning the Glass • Frequency: See chart on page 15 • By: Homeowner a. Be sure the appliance is allowed to cool. b. Clean glass with a non-abrasive commercially available cleaner. Wipe down with dry towel. 5. Ash Removal System Inspection & Cleaning • Frequency: Monthly or after burning 50 bags • By: Homeowner a. Be sure the appliance is allowed to cool. b. Open the front cast door and cycle the ash removal handle - these should be inspected for functionality c. Inspect for any degradation or deformation.  As the springs heat up and cool down they can lose tension  If there is a gap showing above the fi repot bottom, approximately 1/16 inch (1.59mm) or more, it means the springs have lost their tension  Lost tension cannot keep the fl oor in the proper position causing ignition problems and fuel falling into the ash pan. If noted, call your dealer to replace the springs. 8. Door Latch & Gasket Inspection • Frequency: See chart on page 15 • By: Homeowner The door latch is non-adjustable but the gasketing between the glass and fi rebox should be inspected periodically to make sure there is a good seal. If the gasket is frayed or damaged, replace with a new one. WARNING Risk of fi re! Do NOT store fuel: • Closer than required clearances to combustibles to appliance. • Within space required for loading or ash removal

October 27, 2014

7080-132D 19 MT. VERNON E2 Figure 19.1 NOTE • This unit is required to be cleaned frequently because soot creosote and ash may accumulate. 10. Cleaning Convection Blower Requires No Lubrication • Frequency: See chart on page 15 • By: Homeowner a. Be sure the appliance is allowed to cool. b. Remove blower per replacement section instructions. c. Use a soft brush and vacuum to clean the blower wheel. 11. Cleaning the Top Vent Adapter (if installed) • Frequency: As needed • By: Homeowner a. Be sure the appliance is allowed to cool. b. Open the clean out cover. c. Sweep out any ash build-up. 12. Soot and Fly-ash: Formation & Need for Removal in Exhaust Venting System. • Frequency: See chart on page 15 • By: Qualifi ed Service Technician and/or Homeowner a. The products of combustion will contain small particles of fl y-ash. The fl y-ash will collect in the exhaust venting system and restrict the fl ow of the fl ue gases. Incom- plete combustion, such as occurs during startup, shut- down, or incorrect operation of the room heater will lead to some soot formation which will collect in the exhaust venting system. Note: Ash will build up more quickly in the horizontal venting sections. 13. Preparing Firebox for Non-Burn Season • Frequency: See chart on page 15 • By: Homeowner a. The appliance must be in complete shutdown and allow the appliance to completely cool down. b. Remove all ash from fi rebox and vacuum thoroughly. c. To minimize corrosion, paint all exposed steel, including cast-iron. Use the Touch-Up paint supplied with the appliance or purchase paint from your local dealer. You must use a high-temperature paint made specifi cally for heating appliances. d. Cleaning the fl ue at the end of the burn season will prevent corrosives to build-up and damage the fl ue. D. Soot or Creosote Fire Awareness The chimney should be inspected periodically during the heating season to determine if a creosote build-up has occurred. If a signifi cant layer of creosote has accumulated (1/8 inch [3mm] or more) it should be removed to reduce the risk of chimney fi re. Check daily for creosote build-up until experience shows how often you need to clean to be safe. Be aware that the hotter the fi re the less creosote is deposited, and weekly cleaning may be necessary in the mild weather even though monthly cleaning may be enough in the coldest months. Contact your local municipal or provincial fi re authority for information on how to handle a chimney fi re. In the event of a soot or creosote fi re, close the fi rebox door, exit the building immediately and contact the proper fi re authorities. DO NOT under any circumstances re-enter the building. 9. Cleaning Exhaust System (Requires No Lubrication) • Frequency: See chart on page 15 • By: Homeowner a. Be sure the appliance is allowed to cool. b. Remove blower per replacement section instructions. c. Use a soft brush and vacuum to clean the impeller. d. Vacuum out exhaust path and housing. Figure 19.1 e. Replace fan (make sure elect connections are fully assembled)

October 27, 2014

MT. VERNON E2 Baffle Latches Insert flat head screw driver into “V” section and push down and the bottom of the latch will fall forward off of post Locating ears - 1 on each side. Fit behind bottom edge. Figure 20.2 Figure 20.3 Pellets Back-Up in Feed Tube Firepot Overfills Ash Build-Up in Firebox Figure 20.1 F. Baffl e Removal 1. The appliance must be in complete shutdown, com- pletely cool and the exhaust blower off. 2. Open door. 3. The baffl e is located at the top inside of fi rebox. 4. Remove baffl e by placing a fl at head screw driver into the slot of the latches located in the upper corners and rotate down. The bottom of the latch will fall forward off of the post. Lift the baffl e up and then out toward you. Figure 20.2 5. To replace the baffl e, place the 2 locating ears behind the bottom edge and tilt the baffl e up and into place. 6. The baffl e must be centered in the fi rebox before latching it in place. If it is not centered the latch will slip between the baffl e and side of the fi rebox instead of latching properly. 7. The bottom of the latches will fi t over the posts. Using a screwdriver, rotate the top of the latch up to lock latch into place. WARNING Cast iron is a very heavy material. The baffl e is made of cast iron and therefore is heavy and awkward at times to maneuver. Clear and prepare your work area before you begin. • Glass is 5mm thick high temperature heat-re- sistant ceramic glass. • DO NOT REPLACE with any other material. • Alternate material may shatter and cause injury. WARNING G. Glass Replacement 1. Swing open the face and remove the door from the appliance by lifting the door off of the hinge pins and lay on a fl at surface face down. 2. Using a Phillips head screw driver, remove 4 screws, 2 on the top and 2 on the bottom. Remove metal bracket and then remove the glass. Figure 20.3 3. Replace with new glass with gasket. 4. Re-attach metal bracket with 4 screws. 5. Re-install door over hinge pins and close face. E. High Ash Fuel Content Maintenance • Frequency: Daily • By: Homeowner If the ash build-up exceeds the half way point in the fi repot or if clinkers are adhering to the sides of the fi repot, the fi repot fl oor is not being cycled enough. WARNING Risk of Fire and Smoke! • High ash fuels or lack of maintenance can cause fi repot to overfi ll. Follow proper shutdown proce- dure if ash buildup exceeds half way point in fi repot. • Failure to do so could result in smoking, sooting and pos- sible hopper fi res.

October 27, 2014

7080-132D 21 MT. VERNON E2 Figure 21.1 H. Convection Blower Replacement 1. Follow the proper shut down procedures. 2. Remove the left side panel by loosening the 2 screws using a phillips head screw driver or wrench. Figure 21.1 3. Remove two lower sheet metal screws from the back panel to allow more clearance. 4. Disconnect the wire terminals. 5. Reach behind the blower and release the latch by pushing the top of the latch towards the blower. Figure 21.1 6. Rock the top of the blower slightly and lift up. The blower will pass out the left side of the appliance. Note: You may need to loosen the surround to move it out of the way. 7. Install replacement blower by placing the bottom fl ange into the opening fi rst then rotate blower up into position. 8. When the blower is properly positioned the latch will engage the notch to hold the blower in place. Figure 21.1 9. Re-connect wire terminals to the new blower. 10. Reposition and Re-secure the back panel. Note: Make sure wires are connected prior to restarting the appliance. Failure to do so will result in the (side-mounted) safety thermal snap disc tripping resulting in cutting power to the appliance feed system.

October 27, 2014

MT. VERNON E2 I . Combustion/Exhaust Blower Replacement 1. Follow the proper shut down procedures. 2. Remove the right side panel by loosening the 2 screws using a Phillips head screw driver or wrench. Figure 22.1. 3. It is not necessary or recommended to remove the hous- ing to replace or service the combustion blower. You only need to remove the motor and impeller. 4. Disconnect the wire from the control board connection and hall effect switch/housing. 5. Using an 7mm socket wrench or nut driver, loosen the nuts securing the motor and impeller to the housing. 6. Holding the motor, rotate the mounting plate count- er-clockwise and remove motor and impeller. 7. If the gasket between housing and motor is damaged it will have to be replaced. A gasket is included with the replacement blower. 8. Re-install in reverse order. Figure 22.1

October 27, 2014

7080-132D 23 MT. VERNON E2 With proper installation, operation, and maintenance your appliance will provide years of trouble-free service. If you do experience a prob- lem, this troubleshooting guide will assist a qualifi ed service person in the diagnosis of a problem and the corrective action to be taken. This troubleshooting guide can only be used by a qualifi ed service technician. Symptom Possible Cause Corrective Action Plug in appliance - No response. No Power to outlet. Check circuit breaker at service panel. 5 amp fuse blown Replace control board - don’t replace fuse Snap disc tripped or defective. Reset or replace snap disc. Unit will not light No Fuel Check hopper; load with wood pellets Vacuum switch not closing; no vacuum Check vacuum switch wires are installed Check vacuum hose is connected to switch and feed tube port and is in good condition Make sure venting system is clean Make sure front door is closed Check vacuum tube for blockage or restrictions/kink Hopper lid open Close hopper lid Defective hopper switch. Check hopper switch operation Check hopper switch wires for integrity Safety snap disc is tripped Check to make sure convection blower wires are connected and reset snap disc (located on RH side of appliance) Clean & inspect convection blower and convection air path. Feed System is jammed Inspect and un-jam the feed assem- bly Feed motor not plugged in Reconnect feed motor Igniter not plugged in Connect the igniter wires Defective igniter Replace igniter Firepot plugged-up / dirty Clean fi repot and movable fl oor Remove ash from the ashpan Remote receiver is set to “OFF” Set the three-way-switch to “REMOTE” Dial control is set to “OFF” Turn dial control (on the appliance) to a setting other than OFF Fire starts but goes out Dirty fi repot, exhaust path, and/or venting plugged Clean fi repot and movable fl oor Inspect and clean exhaust path and venting Clean fi rebox, exhaust path, and venting (including behind baffl e) Exhaust sensor cannot read tem- perature or is loose Secure the exhaust probe to exhaust blower housing – keeping its wire away from hot surfaces Exhaust plenum is dirty Clean exhaust path to plenum Exhaust probe is defective (error code may result) Check for probe wire integrity and/ or replace defective exhaust probe securing the exhaust probe to exhaust blower housing – keeping its wire away from hot surfaces 4 Troubleshooting Guide

October 27, 2014

MT. VERNON E2 Symptom Possible Cause Corrective Action Appliance starts and stops frequently when operating in the remote mode Area where the thermostat is placed affects temperature. Check thermostat proximity to doors and windows Thermostat located in tight spaces effecting the on/off cycling of the appliance. Inspect remote thermostat location and make sure it is not close to a surface that heats and cools quickly. Remote thermostat SWING function is set too low Raise the thermostat swing tempera- ture (see remote function section for instructions) Slow or smoky start-up and/or lazy fl ame Dirty fi repot, exhaust path, and/or venting system. Clean entire appliance including: fi repot, ash build up in fi rebox, fi repot area, behind baffl e, fi rebox, exhaust blower, venting, and ashpan. Not enough combustion air Adjust the trim (see trim adjustment section) Misaligned igniter Center the igniter in the chamber Wet fuel or poor quality fuel Replace wood pellet fuel Convection blower fails to start Convection Blower is jammed Clean and un-jam the blower Not electrically connected Connect the blower wires to its respective power wires Blower is defective Replace blower Exhaust probe not sensing correct temperature Secure the exhaust probe to exhaust blower housing – keeping its wire away from hot surfaces Control board is defective. Replace control board Convection Blower fails to shut off Wire short between blower and ground - Control board is defective Repair wire and replace control board Exhaust blower fails to start and/or red fl ashes 6X – indicating a exhaust encoder alarm. Exhaust blower is jammed Clean, and un-jam the blower Not electrically connected Connect the blower wires to its respective power wires Blower is defective Replace blower Control board or dial control is defective. Unplug dial control, if exhaust blower runs, dial control is defective. If exhaust blower does not run with dial control unplugged, replace control board. Exhaust Blower fails to shut off Wire short between blower and ground - Control board is defective Repair wire and replace control board Feed Motor fails to shut off Wire short between ground and: feed motor, vacuum switch, hopper switch, or safety snap disc Repair wire(s) and replace control board Control board is defective Replace control board Convection Blower makes noise Convection blower is dirty causing an out-of-balance condition Clean blower impellers Igniter does not turn off Wire short between igniter and ground – Control board is defective Repair wire and replace control board Unit fails to shut off Thermostat, while operating in THERMO mode, does not meet set point temperature Reduce thermostat set point tem- perature to something less than its local temperature Remote thermostat is set to “ON” – not set in THERMO mode Set the thermostat to THERMO and its set point lower than the local temperature or set the thermostat to “OFF” The remote receiver is set to “ON” Set the three-way-switch on the receiver to “REMOTE”

October 27, 2014

7080-132D 25 MT. VERNON E2 Symptom Possible Cause Corrective Action Large, lazy fl ame (orange color) with black ash / soot buildup on glass Dirty appliance or venting Clean unit including the fi repot, exhaust path, and venting system Poor fuel quality, high ash content. Purge old fuel and use higher quality / or brand of fuel Incorrect air-fuel adjustment Adjust the trim (see trim adjustment section) Excessive feeding Adjust trim per trim dial instructions Feed Motor locked on Follow corrective action for feed motor not turning off Excessive fuel spilling over the fi re- pot and/or excessive fl ame Dirty Appliance Clean unit including the fi repot, exhaust path, and venting system Feed Motor locked on Follow corrective action for feed motor not turning off Black soot on the side of the house Dirty Appliance Clean unit including the fi repot, exhaust path, and venting system Exhaust termination cap too close to the structure Extend the termination further from the structure Excessive feeding (incorrect air-fuel ratio) Adjust the trim (see trim adjustment section)

October 27, 2014

MT. VERNON E2 Following correction of any Alarm, turn the dial control to the OFF position, wait 10 seconds and turn back to desired setting OR unplug the unit, wait 10 seconds then restore power. Alarm (LED Flashing RED) Possible Cause Corrective Action 1 Red Flash: Empty Hopper Alarm Hopper empty Fill the hopper Auger jam Inspect the feed tube for jams Vacuum switch not closing Make sure fi rebox door is shut, vacuum hose is connected to switch and drop tube, wire connectors are connected to vacuum switch, control board, hopper switch, and safety snap disc. Hopper lid open Close the hopper lid Exhaust probe does not sense tem- perature Secure the exhaust probe keeping its wire away from hot surfaces and clean the exhaust plenum Snap disc tripped Reset snap disc Exhaust probe not attached to exhaust blower properly Secure exhaust probe to exhaust blower housing – keeping its wire away from hot surfaces Exhaust path is dirty Clean unit including the fi repot, exhaust path, and venting system 2 Red Flashes: Exhaust Probe Fail Not connected to the control board Connect terminal end to control board Failed component Replace exhaust probe – securing it to exhaust blower housing – keeping wire away from hot surfaces 4 Red Flashes: Missed Ignition Hopper empty Fill the hopper Feed motor doesn’t turn Inspect feed motor circuit (hopper lid must be closed, vacuum switch must be closed, snap disc closed, and feed motor must be plugged in) Clear jam in feed tube Dirty appliance Clean unit including the fi repot, exhaust path, and venting system Igniter has no power or is defective Check igniter lead connections or replace igniter Exhaust probe not properly installed Secure exhaust probe to exhaust blower housing – keeping its wire away from hot surfaces Igniter chamber plugged with debris Clean igniter chamber 6 Red Flashes: Exhaust Blower Alarm Wire from exhaust blower or encoder is disconnected or shorted Make sure wire is not damaged / melted and ends are fully connected to the encoder and control board. Defective exhaust blower Replace exhaust blower Defective encoder (on end of exhaust blower) Replace exhaust blower 8 Red Flashes: Exhaust Over-Temp Feed Motor Locked On Repair wire(s) and replace control board Non-approved fuel used Only use wood pellet fuel. Do not enhance its performance with any other combustible substance. Convection blower dirty Clean impellers

October 27, 2014

7080-132D 27 MT. VERNON E2 EXHAUST TEMPERATURE SERIAL PORT (SERVICE ONLY) POT SET TEMP VCC POT SET TEMP GND POT SET TEMP SIG POT FEED ADJUST VCC POT FEED ADJUST GND POT FEED ADJUTS SIG LED RED LED AMBER LED GREEN FUSE M M M 110 V LINE NEUTRAL IGNITER FEED MOTOR EXHAUST BLOWER CONVECTION BLOWER VACUUM SWITCH SNAP DISC BLACK WHITE PURPLE PURPLE BLUE BLUE ORANGE WHITE BLACK BLACK SNAP DISC HOPPER SWITCH THERMOSTAT SIG THERMOSTAT GND THERMOSTAT VCC SPEED SENSOR Figure 27.1 - Control Board Schematic burn back into the feed system, the drop tube snap disc will shut the appliance down. If there is not enough circulation from the convection blower the second snap disc will shut the feed system off. Either sensor must be manually re-set if tripped. Disconnect power before resetting. 12. Exhaust Probe - Exhaust Blower The exhaust probe is a temperature-sensing device attached to the exhaust blower housing via screw and clamp. It pro- vides sympathetic exhaust temperature feedback to the control board. In turn, the control board uses this information to adjust its heat-output systems for best performance. 13. Vacuum Switch The vacuum switch is located on the right side of the appliance under the feed motor, behind right side panel. Its vacuum hose connects to the drop tube. This switch turns the feed system on when vacuum is present in the fi rebox. The vacuum switch is a safety device to shut off the feed motor if the exhaust or the heat exchanger system is dirty, plugged, or if the fi rebox door is open. 14. Remote Thermostat Refer to Thermostat Instructions on page 12. 15. Wiring Schematic for Control Board (below) When describing the location of a component, it is always AS YOU FACE THE FRONT OF THE APPLIANCE. A. Component Functions 1. Exhaust Blower The combustion (exhaust) blower is mounted in the bottom right rear of appliance. The blower is designed to pull the exhaust from the appliance and push it out through the venting system. 2. Control Board The control board is located on the right side of appliance. It controls the functioning of the appliance and communicates with the dial control. The control board can only be replaced by an authorized dealer. 3. Convection Blower The convection blower is mounted at the bottom left of the appliance. The convection blower pushes heated air through the heat exchange system into the room. 4. Feed System The feed system is located on the right side of the appliance and can be removed as an entire assembly. The hollow feed spring (auger) pulls pellets up the feed tube from the hopper area and drops them down the feed chute into the fi repot. Reference the parts list for individual parts in feed assembly . 5. Firepot The fi repot is made of high quality ductile iron. The fl oor of the fi repot opens for cleaning and is manually operated by the homeowner. The fl oor needs to return to a completely closed position or the appliance will not operate properly. 6. Fuse The control board fuse will blow should a short occur. The con- trol board will need to be replaced. DO NOT REPLACE THE FUSE. If the control board fuse blows its TRIAC, that portion of the circuit, will remain closed causing the motor on that leg to run continuously at high speed. 7. Heat Exchanger The heat exchanger is located behind the baffl e and transfers heat from the exhaust system into the convection air chamber. Remove the cast iron baffl e to access the heat exchanger. 8. Hopper Lid Switch The hopper lid switch is located on the right side, inside the hopper. It switches the feed motor off if the hopper lid is open. 9. Igniter (Heating Element) The igniter is mounted on the base of the fi repot. Combustion air travels over the red hot igniter creating super heated air that ignites the pellets. 10. Power Receptacle The power receptacle is located below the control box on right side. Install the power cord (supplied in the appli- ance component pack) to the appliance receptacle. Prior to installing, check the wall receptacle for 120 volt, 60 Hz (standard current). Make sure the outlet is grounded and has the correct polarity. A good quality surge protector is highly recommended to protect the appliance electronics. 11. Overheat Snap Discs There are two overheat snap discs located within the elec- tro-mechanical cavity of the appliance. One is mounted on the back of the drop tube in the center of the appliance; the other is mounted in the RH side between the fi rebox and cast side panel. Both snap discs have a reset button. If the fi re tries to  5 Reference Materials

October 27, 2014

MT. VERNON E2 Service Parts R MT VERNON E2 Beginning Manufacturing Date: Feb 2014 Ending Manufacturing Date: Active Pellet Stove MTV-E2-CSB, MTV-E2-MBK, MTV-E2-PBK, MTV-E2-PDB, MTV-E2-PFT, MTV-E2-PMH Part number list on following page. 09/14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 6 26 21 22 23 24 25 27 28 29 30 31 32 22 33 34 35 36 37 B. Exploded Drawings

October 27, 2014

7080-132D 29 MT. VERNON E2 Service Parts R MT VERNON E2 Beginning Manufacturing Date: Feb 2014 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor. Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 1 Hopper Lid Matte Black 7034-157MBK Porcelain Black 7034-157PBK Porcelain Dark Blue 7034-157PDB Porcelain Frost 7034-157PFT Porcelain Mahogany 7034-157PMH Sienna Bronze 7034-157CSB Gasket, Hopper Lid 10 FT 7000-320/10 2 Hinge Pin SRV7034-159 3 Hinge Retainer SRV7034-163 4 Top Matte Black 7034-155MBK Porcelain Black 7034-155PBK Porcelain Dark Blue 7034-155PDB Porcelain Frost 7034-155PFT Porcelain Mahogany 7034-155PMH Sienna Bronze 7034-155CSB 5 Shroud Left SRV7080-123 6 Side (Interchangeable) Matte Black 7005-107MBK Porcelain Black 7005-107PBK Porcelain Dark Blue 7005-107PDB Porcelain Frost 7005-107PFT Porcelain Mahogany 7005-107PMH Sienna Bronze 7005-107CSB 7 Side Mount Left 7034-128 8 Hinge Male 7034-138 9 Gasket, Door Rope SRV7034-177 Y 10 Latch, Baffl e 7034-149 11 Baffl e SRV7034-263 Y Additional service part numbers appear on following page. C. Parts List

October 27, 2014

MT. VERNON E2 Service Parts R MT VERNON E2 Beginning Manufacturing Date: Feb 2014 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor. Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 12 Door Assembly SRV7080-015 12.1 Glass Retainer 7034-136 Y 12.2 Glass Assembly w/Gasket 7034-007 Y Gasket, Channel 1/8 x 1-1/4 x 10 7000-377/10 12.3 Hinge Female 450-2910 12.4 Door Latch Assembly 413-5200 13 Front, Face Matte Black 7005-108MBK Porcelain Black 7005-108PBK Porcelain Dark Blue 7005-108PDB Porcelain Frost 7005-108PFT Porcelain Mahogany 7005-108PMH Sienna Bronze 7005-108CSB 14 Door Left Matte Black 7005-110MBK Porcelain Black 7005-110PBK Porcelain Dark Blue 7005-110PDB Porcelain Frost 7005-110PFT Porcelain Mahogany 7005-110PMH Sienna Bronze 7005-110CSB 15 Ash Lip Matte Black 7080-140MBK Porcelain Black 7080-140PBK Porcelain Dark Blue 7080-140PDB Porcelain Frost 7080-140PFT Porcelain Mahogany 7080-140PMH Sienna Bronze 7080-140CSB Additional service part numbers appear on following page. 12.1 12.2 12.3 12.4 #12 Door Assembly

October 27, 2014

7080-132D 31 MT. VERNON E2 Service Parts R MT VERNON E2 Beginning Manufacturing Date: Feb 2014 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor. Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 16 Door Right Matte Black 7005-109MBK Porcelain Black 7005-109PBK Porcelain Dark Blue 7005-109PDB Porcelain Frost 7005-109PFT Porcelain Mahogany 7005-109PMH Sienna Bronze 7005-109CSB 17 Ash Pan Door 7034-133 18 Ash Pan Assembly SRV7034-069 Twin Ball Catch SRV7000-532 Y 19 Intake Shield 7034-224 Y 20 Firepot Riser Assembly SRV7080-002 20.1 Firepot Assembly SRV7034-072B Y 20.2 Gasket, Firepot 7034-190 Y 20.3 Spring Pkg of 4 7000-513/4 Y 20.4 Rail, Auto-clean SRV7034-152 Y 20.5 Hitch Pin Clip, 3/32 Pkg of 10 7000-374/10 Y 20.6 Plow Weldment, Auto-clean 7034-024 Y 20.7 Firepot Bottom 7034-153 Y 20.8 Firepot Floor Lever Assembly SRV7080-018 21 Gasket, Rope, Ash Door SRV7034-178 Y 22 Snap Disc, L250F Manual Reset SRV230-1290 Y 23 Latch Bracket Assembly 7034-049 Y Additional service part numbers appear on following page. 20.1 20.2 20.3 20.4 20.5 20.6 20.7 20.8 #20 Firepot Riser Assembly

October 27, 2014

MT. VERNON E2 Service Parts R MT VERNON E2 Beginning Manufacturing Date: Feb 2014 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor. Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 24 Vacuum Switch SRV7000-531 Y Vacuum Hose 3 Ft cut to fi t SRV7000-373 Y 25 Control Board SRV7080-050 Y Wire Harness SRV7080-129 Y 26 Side Mount, Right 7034-126 27 Shroud Right SRV7080-122 Y 28 Control Panel Assembly w/Wire Harness SRV7080-036 29 Control Panel Door Assembly w/Control Panel Assembly SRV7080-037 30 Combustion Blower SRV7080-106 Y Combustion Blower Gasket, Between Housing and Stove SRV7080-117 Y Combustion Blower Motor Gasket, Between Motor and Housing SRV7080-107 Y 31 Wireless Thermostat Receiver SRV7080-109 Y Wireless Thermostat SRV7080-108 Y 32 Flue Collar Assembly SRV7080-013 33 Exhaust Transition Assembly 7034-139 34 Feed Assembly SRV7080-010 Y Feed Spring Assembly (Only) SRV7001-046 Y Gasket, Feed Motor 7034-144 Feed Motor 812-4421 Y 35 Elbow Catch 7000-393 36 Convection Blower SRV7080-105 Y 37 Magnetic Switch 7000-375 Y Additional service part numbers appear on following page.

October 27, 2014

7080-132D 33 MT. VERNON E2 Service Parts R MT VERNON E2 Beginning Manufacturing Date: Feb 2014 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor. Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Component Pack Assembly (Includes Owners Manual, Quick Start Guide, Heat Exchange & Exhaust Cleaning Instructions, Warranty Card, Dvd “How To”, Wall Control & Harness, Power Cord, (4) Leveling Nuts & Bolts, Firepot Clean-Out Tool, Touch- Up Paint and Label Matte Black SRV7080-040 Porcelain Black SRV7080-043 Porcelain Dark Blue SRV7080-044 Porcelain Frost SRV7080-045 Porcelain Mahogany SRV7080-042 Sienna Bronze SRV7080-041 Cleanout Tool 414-1140 Y Leveling Assembly 7000-000 Paint Touch-Up Matte Black 812-0910 Porcelain Black 1-00-0022 Porcelain Dark Blue 1-00-0020 Porcelain Frost 1-00-0021 Porcelain Mahogany 855-1450 Sienna Bronze TOUCHUP-CSB Power Cord 812-1180 Y Exhaust Probe SRV7000-669 Heating Element Assembly 18”, 120 VAC, 300 Watt, (Wood Pellet Fuel Only) SRV7000-647 Y Pkg of 10 SRV7000-647/10 Y Wing Thumb Screw 8-32 X 1/2 Pkg of 24 7000-223/24 Y Wire Clip Pkg of 10 7000-400/10 Y ACCESSORIES Collar, Offset, Top Vent 812-3570 Damper, 3 Inch - Tall Vertical Installs Only PEL-DAMP3 Y Damper, 4 Inch - Tall Vertical Installs Only PEL-DAMP4 Firescreen No Longer Available SCR-7005 Log Set, (Sold as Set only) 2 Pc LOGS-60-AE-B Outside Air Kit OAK-3 Top Vent Adapter TPVNT-3 Warming Shelves Matte Black 844-9780 Porcelain Black WSLG-PBK Porcelain Dark Blue WSLG-PDB Porcelain Frost WSLG-PFT Porcelain Mahogany 844-9810 Sienna Bronze WSLG-CSB

October 27, 2014

DO NOT DISCARD THIS MANUAL CAUTION • Important operating and maintenance instruc- tions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instruc- tions for safe installa- tion and operation. DO NOT DISCARD CONTACT INFORMATION Hearth & Home Technologies 1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafi re.com This product may be covered by one or more of the following patents: (United States) 5341794, 5263471, 6688302, 7216645, 7047962 or other U.S. and foreign patents pending. We recommend that you record the following pertinent information for your heating appliance. Date purchased/installed: Serial Number: Location on appliance: Dealership purchased from: Dealer phone: Notes:

Other Pellet stove Manuals