Hirschmann MACH 1020 Operation & User’s Manual
Read Online
Read the Hirschmann MACH 1020 Operation & User’s Manual online using the built-in PDF viewer.
Text of the manual
Release 02 10/10
Technical Support
[email protected]
User Manual
Installation
Industrial ETHERNET Ruggedized Switch
MACH 1000 Family
MACH 1020
LS DA
USB
V.24
MACH 1020
LS DA
3
4
9
10
P
StandBy
RM
FAULT
R1 R2
5
6
7
8
13
14
11
12
17
18
15
16
21
22
19
20
25
26
23
24
LS DA
LS DA
LS DA
LS DA
MACH 1030
LS DA
USB
V.24
MACH 1030
2
1
LS DA
3
4
9
10
P
StandBy
RM
FAULT
R1 R2
5
6
7
8
13
14
11
12
17
18
15
16
21
22
19
20
25
26
23
24
LS DA
LS DA
LS DA
LS DA
LS DA
USB
V.24
MACH 1000
2
1
LS DA
3
4
9
10
P
StandBy
RM
FAULT
R1 R2
5
6
7
8
13
14
11
12
17
18
15
16
21
22
19
20
25
26
23
24
22
MACH 1132
3
4
5
6
LS DA
LS DA
LS DA
MACH 1032
USB
V.24
P
StandBy
RM
FAULT
R1 R2
2
1
P
StandBy
RM
FAULT
R1 R2
ETHERNET Service Port
1
3
5
7
9
11 13 15 17 19 21 23
2
4
6
8
10 12 14 16 18 20 22 24
LS DA
USB
V.24
MACH 1000
2
1
LS DA
3
4
9
10
P
StandBy
RM
FAULT
R1 R2
5
6
7
8
13
14
11
12
17
18
15
16
21
22
19
20
25
26
23
24
USB
V.24
P
StandBy
RM
FAULT
R1 R2
The naming of copyrighted trademarks in this manual, even when not specially indicated, should
not be taken to mean that these names may be considered as free in the sense of the trademark
and tradename protection law and hence that they may be freely used by anyone.
© 2010 Hirschmann Automation and Control GmbH
Manuals and software are protected by copyright. All rights reserved. The copying, reproduction,
translation, conversion into any electronic medium or machine scannable form is not permitted,
either in whole or in part. An exception is the preparation of a backup copy of the software for
your own use. For devices with embedded software, the end-user license agreement on the
enclosed CD applies.
The performance features described here are binding only if they have been expressly agreed
when the contract was made. This document was produced by Hirschmann Automation and
Control GmbH according to the best of the company's knowledge. Hirschmann reserves the right
to change the contents of this document without prior notice. Hirschmann can give no guarantee
in respect of the correctness or accuracy of the information in this document.
Hirschmann can accept no responsibility for damages, resulting from the use of the network
components or the associated operating software. In addition, we refer to the conditions of use
specified in the license contract.
You can get the latest version of this manual on the Internet at the Hirschmann product site
(www.beldensolutions.com).
Printed in Germany
Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany
Tel.: +49 1805 141538
MACH 1000 039 687-002-02-1010
14.10.10
Release 02 10/10
3
Contents
Safety instructions
4
About this Manual
10
Legend
10
1
Device description
11
1.1
Description of the device variants
12
1.2
Combination options
18
2
Assembly and start-up
21
2.1
Installing the device
21
2.1.1
Unpacking and checking
21
2.1.2
Installing the SFP modules (optional)
21
2.1.3
Connecting the power unit connections
for supply voltage and signal contact
22
2.1.4
Installing the device and grounding
30
2.1.5
Startup procedure
34
2.1.6
Connecting the data lines
34
2.2
Display elements
38
2.3
Basic set-up
41
2.4
Disassembling the device
43
3
Technical data
44
A
Further Support
53
Release 02 10/10
Safety instructions
This documentation contains instructions which must be observed to ensure
your own personal safety and to avoid damage to devices and machinery.
Certified usage
The device may only be employed for the purposes described in the
catalog and technical description, and only in conjunction with external
devices and components recommended or
approved by the manufacturer. The product can only be operated cor-
rectly and safely if it is transported, stored, installed and assembled pro-
perly and correctly. Furthermore, it must be operated and serviced
carefully.
Supply voltage
The supply voltage is electrically isolated from the housing.
Use undamaged parts.
The device does not contain any service components. Internal fuses
are only triggered if there is a fault in the device. If the device is not
functioning correctly, or if it is damaged, switch off the voltage supply
and return the device to the plant for inspection.
Only switch on the device when the housing is closed.
Connect the protective conductor before you set up the other
connections. When removing the connections, you remove the
protective conductor last.
Connect both protective conductors if your device is equipped with two
power supply units.
Make sure that the cross-section of the protective conductor cable is
the same size as or bigger than the cross-section of the voltage supply
cables.
Only use connection cables that are permitted for the specified
temperature range.
Warning: Never insert sharp objects (small screwdrivers, wires,
etc.) into the field connection terminals for the supply voltage,
and do not touch the terminals! There is the risk of an electric
shock.
Release 02 10/10
5
Warning:
– If the neutral conductor or the negative terminal of the supply
voltage is not grounded
– If you are using a DC voltage greater than 125 VDC for the
supply voltage install a suitable input fuse.
For power supply units with product code “G” or “M”, use a slow-
blow fuse with a nominal rating of 2.5 A for the voltage supply
input.
For power supply units with product code “C” or “L”, use a slow-
blow fuse with a nominal rating of 6.3 A.
With AC power supply, use a cable cross-section of at least 0.75
mm² (North America: AWG 18) for the current conductor at the
voltage input.
With DC power supply, use a cable cross-section of at least 1.0
mm² (North America: AWG 16) for the current conductor at the
voltage input.
Relevant for North America: For use in Class 2 circuits.
Only use copper wire/conductors of class 1, 60/75°C or 75°C.
Warning: Only connect a supply voltage that corresponds to
the type plate of your device.
Power unit type “C” and “L”: 18 to 60 V DC
Power unit type “G” and “M”: 77 to 300 V DC or 90 to 265 V AC
Shielding ground
The shielding ground of the connectable twisted pairs lines is connected
to the front panel as a conductor.
Beware of possible short circuits when connecting a cable section with
conductive shielding braiding.
Housing
Only technicians authorized by the manufacturer are permitted to open
the housing.
Depending on the device variant, it is grounded
via a separate spring-loaded terminal. This is located at the 1 or 2
power supply module(s) on the back of the device.
via a ground connection on the front panel of the device.
Make sure that the electrical installation meets local or nationally
applicable safety regulations.
The ventilation slots must not be covered so as to ensure free air
circulation.
The clearance to the ventilation slots of the housing must be at least
10 cm (3.94 in).
Do not touch the housing during operation or shortly after switching off
the device. Hot surfaces can cause injury.
Release 02 10/10
Warning!
Never insert sharp objects (small screwdrivers, wires, etc.) into
the inside of the product. There is the risk of an electric shock.
The device must be installed in the horizontal or upright position, either
in the switch cabinet or on the wall (see on page 30 “Installing the
device and grounding”) The device is not intended for operation as a
table unit.
Operating the device in the maximum surrounding air temperature and
stacking devices: When installing the device, make sure there is at
least one free rack space (approx. 5 cm) above the device, because
heat is discharged via the housing of the device.
If you are operating the device in a 19" switch cabinet: install sliding/
mounting rails for holding the device (see on page 30 “Installing the
device and grounding”).
Warning: Only install the device in rooms / plants that are only
accessible to trained maintenance personnel.
If installed in a living area or office environment, the device must be
operated exclusively in switch cabinets with fire protection
characteristics in accordance with EN 60950-1.
Warning: Never insert sharp objects (small screwdrivers, wires,
etc.) into the field connection terminals for the supply voltage,
and do not touch the terminals! There is the risk of an electric
shock.
Environment
The device may only be operated at the specified surrounding air
temperature (temperature of the surrounding air at a distance of up to 5
cm (1.97 in) from the device) and relative air humidity specified in the
technical data.
Install the device in a location where the climatic threshold values
specified in the technical data will be observed.
Use the device only in an environment within the contamination level
specified in the technical data.
Qualification requirements for personnel
Qualified personnel as understood in this manual and the warning signs,
are persons who are familiar with the setup, assembly, startup, and
operation of this product and are appropriately qualified for their job. This
includes, for example, those persons who have been:
Release 02 10/10
7
trained or directed or authorized to switch on and off, to ground and to
label power circuits and devices or systems in accordance with current
safety engineering standards;
trained or directed in the care and use of appropriate safety equipment
in accordance with the current standards of safety engineering;
trained in providing first aid.
General safety instructions
Electricity is used to operate this equipment. Comply with every detail of
the safety requirements specified in the operating instructions regarding
the voltages to apply (see page 4).
Non-observance of these safety instructions can therefore cause material
damage and/or serious injuries.
Only appropriately qualified personnel should work on this device or in
its vicinity. These personnel must be thoroughly familiar with all the
warnings and maintenance procedures in accordance with this
operating manual.
The proper and safe operation of this device depends on proper
handling during transport, proper storage and assembly, and
conscientious operation and maintenance procedures.
Never start operation with damaged components.
Only use the devices in accordance with this manual. In particular,
observe all warnings and safety-related information.
Any work that may be required on the electrical installation may only
be carried out by personnel trained for this purpose.
Please note that products recommended as accessories may have
characteristics that do not fully correspond to those of the
corresponding product. This may limit their possible usage in the
overall system.
Note: LED or LASER components in compliance with IEC 60825-1
(2001):
CLASS 1 LASER PRODUCT
CLASS 1 LED PRODUCT
Release 02 10/10
Warning
Laser light
Do not look into the beam or view it directly with optical
instruments (e.g. magnifying glass, microscope).
Failure to observe this warning within a distance of 100 mm can
endanger your sight.
Light is emitted from the optical connections or from the ends of
the optical fibers that are connected to them. Light Emitting
Diode CLASS 2M, wave length 650 nm, power <2 mW,
according to DIN EN 60825-1:2003-10.
National and international safety regulations
Make sure that the electrical installation meets local or nationally
applicable safety regulations.
CE marking
The devices comply with the regulations contained in the following
European directive(s):
2004/108/EG
Directive of the European Parliament and the council for standardizing
the regulations of member states with regard to electromagnetic
compatibility.
2006/95/EG
Directive of the European Parliament and the council for standardizing the
regulations of member states with regard to electrical equipment to be
used within specific voltage ranges.
In accordance with the above-named EU directive(s), the EU conformity
declaration will be at the disposal of the relevant authorities at the
following address:
Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Tel.: +49 1805 141538
The product can be used in the industrial sector.
Interference immunity: EN 61000-6-2:2005
Emitted interference: EN 55022:2006 + A1:2007 Class A
Safety: EN 60950-1:2006
Release 02 10/10
9
Warning!
This is a class A device. This device can cause interference in
living areas, and in this case the operator may be required to
take appropriate measures.
Warning!
The assembly guidelines provided in these instructions must be
strictly adhered to in order to observe the EMC threshold values.
FCC note:
This device complies with part 15 of FCC rules. Operation is subject to the
following two conditions : (1) This device may not cause harmful
interference; (2) this device must accept any interference received,
including interference that may cause undesired operation.
Appropriate testing has established that this device fulfills the
requirements of a class A digital device in line with part 15 of the FCC
regulations.
These requirements are designed to provide sufficient protection against
interference when the device is being used in a business environment.
The device creates and uses high frequencies and can radiate same, and
if it is not installed and used in accordance with this operating manual, it
can cause radio transmission interference. The use of this device in a
living area can also cause interference, and in this case the user is
obliged to cover the costs of removing the interference.
Recycling note
After usage, this product must be disposed of properly as electronic
waste, in accordance with the current disposal regulations of your county,
state and country.
Release 02 10/10
About this Manual
The “Installation” user manual contains a device description, safety
instructions, a description of the display, and the other information that you
need to install the device.
The following manuals are available as PDF files on the CD-ROM supplied:
Installation user manual
Basic Configuration user manual
Redundancy Configuration user manual
Web-based Interface reference guide
Command Line Interface user manual
The HiVision Network Management Software provides you with additional
options for smooth configuration and monitoring:
Event log
Configuration of “System Location” and “System Name”
Configuration of the network address range and the SNMP parameters
Saving the configuration on the device
Simultaneous configuration of multiple devices
Configuration of the port display color red for a connection error
With the Industrial HiVision Network Management software, you increase
your network security in industrial application areas:
ETHERNET Early Warning System
Easy monitoring of industrial networks
Fast display
Interface with diagnostic and configuration programs
Low deployment cost
Legend
The symbols used in this manual have the following meanings:
Listing
Work step
Subheading
Release 02 10/10
11
1
Device description
The Ruggedized Switch for Substations and Transportation MACH 1000
Family provides you with a wide range of Switch variants. You set up your
own Switch according to your requirements regarding the number of ports,
transmission speed, media type, connector type, temperature range, voltage
range and software variant.
The MACH 1000 devices are designed for the special requirements of
industrial automation. They meet the relevant industry standards, provide
very high operational reliability, even under extreme conditions, and also
long-term reliability and flexibility. The devices work without a fan. If required,
the devices are PoE-capable. For devices without PoE, the voltage supply
can be redundant if required. The Switches are mounted in the switch cabinet
by means of brackets, or vertically on the wall.
The HIPER-Ring redundancy concept enables you to quickly carry out a
reconfiguration, and also a simple configuration with only one additional
connection. Diagnosis displays and the display of the operating parameters
provide a quick overview.
It can be easily managed via a Web browser, via Telnet, with a management
software product (such as HiVision) or locally on the switch (V.24 interface).
The device allows you to set up switched industrial ETHERNET networks
that conform to the IEEE 802.3 and 802.3u standards using copper wires or
optical fibers in a line or ring structure. You can connect terminal devices and
other infrastructure components via twisted pair cables, multi-mode F/O and
single-mode F/O. The twisted pair ports support
autocrossing, autonegotiation and autopolarity.
Depending on the software you choose, the devices provide you with a large
range of functions:
Redundancy functions
(Rapid Spanning Tree, Redundant Ring Structure, HIPER-Ring,
Redundant Coupling, Link Aggregation, for devices without PoE
Redundant Power Supply)
Protection from unauthorized access
Synchronized system time in the network
Network load control
Operation diagnosis
Diagnostics (hardware self-testing)
Reset
Priority
VLAN
Topology Discovery
Web-based Interface
Command Line Interface CLI
Release 02 10/10
SNMP
802.1x port authentication
Real Time Clock (Professional software variant)
The addition, to the MACH 1000 Ruggedized Switch series, of the switches
of the Open Rail range, the MICE range, the backbone switches of the MACH
3000 and MACH 4000 ranges, the BAT wireless transmission system, the
EAGLE security system, and products for the LION control room, provides
continuous communication across all levels of the company.
1.1
Description of the device variants
The devices differ with regard to the range of software functions, the number
of interfaces, and the media type for connecting segments.
The MAR1020-..., MAR1022-..., MAR1120-... and MAR1122-... device
variants are MACH 1000 Ruggedized Switches without Gigabit ports and,
depending on the requirements, a selectable number (up to 24) of Fast
Ethernet ports (10/100 Mbit/s). You can choose the media for the Fast
Ethernet ports 1 to 24 in pairs.
The MAR1120-... and MAR1122-... devices have an additional Fast
Ethernet port on the front of the device that you can use for diagnosis
purposes.
The MAR1022-... devices support PoE in accordance with IEEE
802.3af.
The PoE ports are the Fast Ethernet ports 1 to 4.
In the MAR1120-... devices, all the cable outlets are at the back, i.e.
the ports are on the back of the device.
The MAR1122-... devices support PoE in accordance with IEEE
802.3af.
The PoE ports are the Fast Ethernet ports 1 to 4.
All the cable outlets are at the back, i.e. the ports are on the back of
the device.
The MAR1030-..., MAR1032-..., MAR1130-... and MAR1132-... device
variants are MACH 1000 Ruggedized Switches with 2 or 4 Gigabit ports
(10/100/1000 Mbit/s) and, depending on the requirements, a selectable
number (up to 24) of Fast Ethernet ports (10/100 Mbit/s).
You can choose the media for the Fast Ethernet ports 1 to 24 in pairs.
In device variants with 2 Gigabit Ethernet ports, these ports are combo
ports (2 x SFP slot: 100/1000 Mbit/s, alternatively:
2 x twisted pair RJ45 socket: 10/100/1000 Mbit/s).
In device variants with 4 Gigabit Ethernet ports, these can be optionally -
SFP slots (2 x 2 slots),
Release 02 10/10
13
- twisted pair RJ45 sockets (2 x 2 sockets) or
- 2 x SFP slots plus 2 x twisted pair RJ45 sockets.
The MAR1130-... and MAR1132-... devices have an additional Fast
Ethernet port on the front of the device that you can use for diagnosis
purposes.
The MAR1032-... devices support PoE (Power over Ethernet) in
accordance with IEEE 802.3af. The PoE ports are the Fast Ethernet
ports 1 to 4.
In the MAR1130-... devices, all the cable outlets are at the back, i.e.
the ports are on the back of the device.
The MAR1132-... devices support PoE (Power over Ethernet) in
accordance with IEEE 802.3af. The PoE ports are the Fast Ethernet
ports 1 to 4.
In these devices, all the cable outlets are at the back, i.e. the ports are
on the back of the device.
The devices also provide you with the following options for selecting the
variant you desire:
Temperature range:
Standard 0 °C to +60 °C
Extended -40 °C to +85 °C
Extended -40 °C to +85 °C, conformal coating
Voltage range for power supply unit 1 and the optional power supply
unit 2:
18 VDC to 60 VDC
77 VDC to 300 VDC or 90 VAC to 265 VAC
The voltage supply connection can be a terminal or plugged connection,
as desired.
In devices with PoE, power supply unit 2 is the PoE power supply unit.
You can choose the connections to power supply unit 1.
Software variant: Professional
The devices comply with the specifications of the ISO/IEC standards
8802-3u 100BASE-TX/-1000BASE-T,
8802-3 100BASE-FX and
8802-3 1000BASE-SX/LX.
Release 02 10/10
Front view of the MACH 1000 with 2 Gigabit ports
Figure 1: 1 - LED display elements
2 - USB interface
3 - V.24 connection for external management
4 - See following table, column 1
5 - See following table, column 2
Front view of the MACH 1000 with 4 Gigabit ports (SFP)
Figure 2: 1 - LED display elements
2 - USB interface
3 - V.24 connection for external management
4 - See following table, column 1
5 - See following table, column 2
Gigabit ETHERNET
GE ports 1 and 2 (combo ports)
Fast ETHERNET
FE ports 1 to 24, free choice of connections
100/1000 Mbit/s
Fiber optic, SFP slots
Alternative connections:
10/100/1000 Mbit/s
Twisted pair, RJ45 connections
99:
TT:
MM:
JJ:
NN:
VV:
UU:
LL:
GG:
ZZ:
RR:
FF:
Module position empty
2 * twisted pair TX, RJ45, 10/100 Mbit/s
2 * Multimode FX DSC 100 Mbit/s
2 * Multimode FX MTRJ 100 Mbit/s
2 * Multimode FX ST 100 Mbit/s
2 * Singlemode FX DSC 100 Mbit/s
2 * Singlemode FX ST 100 Mbit/s
2 * Singlemode Long Haul FX DSC 100 Mbit/s
2 * Singlemode Long Haul FX DSC 200 km 100 Mbit/s
2 * SFP slot 100 Mbit/s
2 * twisted pair TX, M12, 10/100 Mbit/s
2 * Multimode FL ST 10 Mbit/s
LS DA
USB
V.24
MACH 1000
2
1
LS DA
3
4
9
10
P
StandBy
RM
FAULT
R1 R2
5
6
7
8
13
14
11
12
17
18
15
16
21
22
19
20
25
26
23
24
LS DA
LS DA
MACH 1000
1
2
5
6
9
10
13
14
17
18
21
22
3
4
7
8
11
12
15
16
19
20
23
24
1
2
1
2
4
5
3
LS DA
USB
V.24
MACH 1000
2
1
LS DA
3
4
9
10
P
StandBy
RM
FAULT
R1 R2
5
6
7
8
13
14
11
12
17
18
15
16
21
22
19
20
25
26
23
24
MACH 1000
1
2
5
6
9
10
13
14
17
18
21
22
3
4
7
8
11
12
15
16
19
20
23
24
1
2
3
4
USB
V.24
P
StandBy
RM
FAULT
R1 R2
1
2
4
5
3
Release 02 10/10
15
Front view of the MACH 1000 with 4 Gigabit ports
(2 x SFP and 2 x RJ45)
Figure 3: 1 - LED display elements
2 - USB interface
3 - V.24 connection for external management
4 - See following table, column 1
5 - See following table, column 2
Gigabit ETHERNET
GE ports 1 to 4
Fast ETHERNET
FE ports 1 to 24, free choice of connections
1000 Mbit/s
Fiber optic, SFP slots
99:
TT:
MM:
JJ:
NN:
VV:
UU:
LL:
GG:
ZZ:
RR:
FF:
Module position empty
2 * twisted pair TX, RJ45, 10/100 Mbit/s
2 * Multimode FX DSC 100 Mbit/s
2 * Multimode FX MTRJ 100 Mbit/s
2 * Multimode FX ST 100 Mbit/s
2 * Singlemode FX DSC 100 Mbit/s
2 * Singlemode FX ST 100 Mbit/s
2 * Singlemode Long Haul FX DSC 100 Mbit/s
2 * Singlemode Long Haul FX DSC 200 km 100 Mbit/s
2 * SFP slot 100 Mbit/s
2 * twisted pair TX, M12, 10/100 Mbit/s
2 * Multimode FL ST 10 Mbit/s
Gigabit ETHERNET
GE ports 1 to 4
Fast ETHERNET
FE ports 1 to 24, free choice of connections
1000 Mbit/s
Fiber optic, SFP slots
And / or:
10/100/1000 Mbit/s
Twisted pair, RJ45 connections
99:
TT:
MM:
JJ:
NN:
VV:
UU:
LL:
GG:
ZZ:
RR:
FF:
Module position empty
2 * twisted pair TX, RJ45, 10/100 Mbit/s
2 * Multimode FX DSC 100 Mbit/s
2 * Multimode FX MTRJ 100 Mbit/s
2 * Multimode FX ST 100 Mbit/s
2 * Singlemode FX DSC 100 Mbit/s
2 * Singlemode FX ST 100 Mbit/s
2 * Singlemode Long Haul FX DSC 100 Mbit/s
2 * Singlemode Long Haul FX DSC 200 km 100 Mbit/s
2 * SFP slot 100 Mbit/s
2 * twisted pair TX, M12, 10/100 Mbit/s
2 * Multimode FL ST 10 Mbit/s
LS DA
USB
V.24
MACH 1000
2
1
LS DA
3
4
9
10
P
StandBy
RM
FAULT
R1 R2
5
6
7
8
13
14
11
12
17
18
15
16
21
22
19
20
25
26
23
24
MACH 1000
1
2
5
6
9
10
13
14
17
18
21
22
3
4
7
8
11
12
15
16
19
20
23
24
1
2
3
4
USB
V.24
P
StandBy
RM
FAULT
R1 R2
2
1
2
4
5
3
Release 02 10/10
Front view of the MACH 1000 with PoE
Figure 4: 1 - LED display elements
2 - USB interface
3 - V.24 connection for external management
4 - See below table 1, column 1
5 - See below table 1, column 2
6 - See below table 2
Gigabit ETHERNET
Up to 4 GE ports
Fast ETHERNET
FE ports 1 to 4, Power over Ethernet
1000 Mbit/s
Fiber optic, SFP slots
And / or:
10/100/1000 Mbit/s
Twisted pair, RJ45 connections
TT:
RR:
2 * twisted pair TX, RJ45, 10/100 Mbit/s
2 * twisted pair TX, M12, 10/100 Mbit/s
Table 1: Gigabit ETHERNET, Fast ETHERNET FE ports 1 to 4
Fast ETHERNET
FE ports 5 to 24, free choice of connections
99:
TT:
MM:
JJ:
NN:
VV:
UU:
LL:
GG:
ZZ:
RR:
FF:
Module position empty
2 * twisted pair TX, RJ45, 10/100 Mbit/s
2 * Multimode FX DSC 100 Mbit/s
2 * Multimode FX MTRJ 100 Mbit/s
2 * Multimode FX ST 100 Mbit/s
2 * Singlemode FX DSC 100 Mbit/s
2 * Singlemode FX ST 100 Mbit/s
2 * Singlemode Long Haul FX DSC 100 Mbit/s
2 * Singlemode Long Haul FX DSC 200 km 100 Mbit/s
2 * SFP slot 100 Mbit/s
2 * twisted pair TX, M12, 10/100 Mbit/s
2 * Multimode FL ST 10 Mbit/s
Table 2: Fast ETHERNET, FE ports 5 to 24
LS DA
USB
V.24
MACH 1000
2
1
LS DA
3
4
9
10
P
StandBy
RM
FAULT
R1 R2
5
6
7
8
13
14
11
12
17
18
15
16
21
22
19
20
25
26
23
24
LS DA
LS DA
MACH 1000
1
2
5
6
9
10
13
14
17
18
21
22
7
8
11
12
15
16
19
20
23
24
1
2
3
4
LS DA
LS DA
USB
V.24
P
StandBy
RM
FAULT
R1 R2
2
1
2
4
5
6
3
P
Power over
ETHERNET
Release 02 10/10
17
Views of the MACH 1000, ports in the back
Figure 5: Front panel:
1 - LED display elements
2 - Diagnosis port
Figure 6: Rear panel:
1 - LED display elements
2 - USB interface
3 - V.24 connection for external management
4 - See following table, column 1
5 - See following table, column 2
The device variants of the MACH 1000 with ports on the rear panel
have the following characteristics:
The display LEDs are on the front of the device. There are up to 4
LEDs for displaying the status of the Gigabit Ethernet ports and up to
21 LEDs for displaying the status of the Fast Ethernet ports, as well as
6 LEDs for displaying the device status.
The supply voltage connection and the ports are on the back of the
device. The device allows you to connect a maximum of 20 Fast
Ethernet ports as well as an additional Fast Ethernet port on the front
of the device that you can use for diagnosis purposes.
Gigabit ETHERNET
Up to 4 GE ports
Fast ETHERNET
FE ports 1 to 20, free choice of connections
1000 Mbit/s
Fiber optic, SFP slots
And / or:
10/100/1000 Mbit/s
Twisted pair, RJ45 connections
99:
TT:
MM:
JJ:
NN:
VV:
UU:
LL:
GG:
ZZ:
RR:
FF:
Module position empty
2 * twisted pair TX, RJ45, 10/100 Mbit/s
2 * Multimode FX DSC 100 Mbit/s
2 * Multimode FX MTRJ 100 Mbit/s
2 * Multimode FX ST 100 Mbit/s
2 * Singlemode FX DSC 100 Mbit/s
2 * Singlemode FX ST 100 Mbit/s
2 * Singlemode Long Haul FX DSC 100 Mbit/s
2 * Singlemode Long Haul FX DSC 200 km 100 Mbit/s
2 * SFP slot 100 Mbit/s
2 * twisted pair TX, M12, 10/100 Mbit/s
2 * Multimode FL ST 10 Mbit/s
P
StandBy
RM
FAULT
R1 R2
ETHERNET Service Port
1
3
5
7
9 11 13 15 17 19 21 23
2
4
6
8 10 12 14 16 18 20 22 24
MACH 1000
1
2
LS DA
USB
V.24
MACH 1000
2
1
LS DA
3
4
9
10
P
StandBy
RM
FAULT
R1 R2
5
6
7
8
13
14
11
12
17
18
15
16
21
22
19
20
25
26
23
24
22
3
4
5
6
LS DA
LS DA
LS DA
USB
V.24
P
StandBy
RM
FAULT
R1 R2
2
1
MACH 1000
1
2
5
6
9
10
13
14
17
18
21
3
4
7
8
11
12
15
16
19
20
23
24
1
2
1
2
4
5
3
-/N +/L
Release 02 10/10
1.2
Combination options
The product designation of your device is made from combining the desired
product characteristics in accordance with the following table. The
corresponding short designation is in column 3.
Item
Characteristic
Ident.
Property
1 to 7
Product
MAR1020
MAR1030
MAR1022
MAR1032
MAR1120
MAR1130
MAR1122
MAR1132
MACH Ruggedized Fast Ethernet Switch
MACH Ruggedized Gigabit Ethernet Switch
MACH Ruggedized Fast Ethernet Switch
with PoE ab
MACH Ruggedized Gigabit Ethernet Switch
with PoE ab
MACH Ruggedized Fast Ethernet Switch,
ports on the back
MACH Ruggedized Gigabit Ethernet Switch,
ports on the back
MACH Ruggedized Fast Ethernet Switch,
ports on the back and with PoE ab
MACH Ruggedized Gigabit Ethernet Switch,
ports on the back and with PoE ab
8
- (hyphen)
-
9 to 10
10/100/1000 Mbit/s ports
1+2 or 1 to 4
99
CC
4O
4T
OT
Not present (in MAR1020)
2 * combo port (SFP slot: 100/1000 Mbit/s,
alternatively twisted pair RJ45 socket: 10/
100/1000 Mbit/s)
2*2 ports Gigabit Ethernet SFP, 1000 Mbit/s
2*2 ports Gigabit Ethernet RJ45
10/100/1000 Mbit/s
2 ports Gigabit Ethernet SFP 1000 Mbit/s
plus 2 ports Gigabit Ethernet RJ45
10/100/1000 Mbit/s
11 to 12
10/100 Mbit/s ports 1+2 a)
99
TT
MM
JJ
NN
VV
UU
LL
GG
ZZ
RR
FF b
Module position empty
2 * twisted pair TX, RJ45, 10/100 Mbit/s
2 * Multimode FX DSC 100 Mbit/s
2 * Multimode FX MTRJ 100 Mbit/s
2 * Multimode FX ST 100 Mbit/s
2 * Singlemode FX DSC 100 Mbit/s
2 * Singlemode FX ST 100 Mbit/s
2 * Singlemode Long Haul FX DSC
100 Mbit/s
2 * Singlemode Long Haul FX DSC 200 km
100 Mbit/s
2 * SFP slot 100 Mbit/s
2 * twisted pair TX, M12, 10/100 Mbit/s
2 * Multimode FL ST 10 Mbit/s
13 to 14
10/100 Mbit/s ports 3 + 4
See 11 to 12
15 to 16
10/100 Mbit/s ports 5 + 6
See 11 to 12
17 to 18
10/100 Mbit/s ports 7 + 8
See 11 to 12
19 to 20
10/100 Mbit/s ports 9 + 10
See 11 to 12
21 to 22
10/100 Mbit/s ports 11 + 12
See 11 to 12
Table 3: Combination options for the device variants of the MACH 1000
Release 02 10/10
19
23 to 24
10/100 Mbit/s ports 13 + 14
See 11 to 12
25 to 26
10/100 Mbit/s ports 15 + 16
See 11 to 12
27 to 28
10/100 Mbit/s ports 17 + 18
See 11 to 12
29 to 30
10/100 Mbit/s ports 19 + 20
See 11 to 12
31 to 32
10/100 Mbit/s ports 21 + 22
See 11 to 12
33 to 34
10/100 Mbit/s ports 23 + 24
See 11 to 12
35
Temperature range
S
Standard 0 °C to +60 °C
U
Extended -40 °C to +85 °C
F
Extended -40 °C to +85 °C, conformal
coating
36
Voltage range
power supply unit 1
C
G
L
M
18 VDC to 60 VDC terminal connection
77 VDC to 300 VDC or 90 VAC to
265 VAC terminal connection
18 VDC to 60 VDC plugged connection
77 VDC to 300 VDC or 90 VAC to
265 VAC plugged connection
37
Voltage range
power supply unit 2
or PoE power supply unit
9
C
G
L
M
Not present
18 VDC to 60 VDC terminal connection
77 VDC to 300 VDC or 90 VAC to
265 VAC terminal connection
18 VDC to 60 VDC plugged connection
77 VDC to 300 VDC or 90 VAC to
265 VAC plugged connection
38
Certifications
H
T
CE, UL 508, GL, IEC 61850, IEEE 1613
Substation, EN 50121-4 Railway (along
track)
CE, UL 508, EN 50121-4 Railway (along
track), EN 50155 Railway (train) c
39
Software variant
P
Professional
a.
In device variants with PoE (Power over Ethernet), the first four ports can be twisted pair TX
RJ45 10/100 Mbit/s (short designation TT) or twisted pair TX M12 10/100 Mbit/s (short
designation RR), as desired. The remaining ports can be selected freely from the table.
Power supply unit 2 is a PoE power supply unit (incoming voltage range, item 37: “G” or “M”).
You can choose the connections to power supply unit 1.
b.
Devices with PoE or with FL ports: No „T“ certification (EN 50155 Railway (train)) available.
c.
Nominal voltage on power supply type G and M: 110 VDC; on power supply type C and L:
36 VDC.
Item
Characteristic
Ident.
Property
Table 3: Combination options for the device variants of the MACH 1000
Release 02 10/10
Example of MACH 1000 product designation
MAR1030-
MACH Ruggedized Switch with Gigabit ports
CC
2 * combo port (SFP slot: 100/1000 Mbit/s, alternatively twisted pair RJ45 socket: 10/100/
1000 Mbit/s)
TT
10/100 Mbit/s ports 1 + 2:
2 * twisted pair TX, RJ45, 10/100 Mbit/s
MM
10/100 Mbit/s ports 3 + 4:
2 * Multimode FX DSC 100 Mbit/s
JJ
10/100 Mbit/s ports 5 + 6:
2 * Multimode FX MTRJ 100 Mbit/s
NN
10/100 Mbit/s ports 7 + 8:
2 * Multimode FX ST 100 Mbit/s
VV
10/100 Mbit/s ports 9 + 10:
2 * Singlemode FX DSC 100 Mbit/s
UU
10/100 Mbit/s ports 11 + 12:
2 * Singlemode FX ST 100 Mbit/s
LL
10/100 Mbit/s ports 13 + 14:
2 * Singlemode Long Haul FX DSC 100 Mbit/s
GG
10/100 Mbit/s ports 15 + 16:
2 * Singlemode Long Haul FX DSC 200 km 100 Mbit/s
ZZ
10/100 Mbit/s ports 17 + 18:
2 * SFP slot 100 Mbit/s
TT
10/100 Mbit/s ports 19 + 20:
2 * twisted pair TX, RJ45, 10/100 Mbit/s
99
10/100 Mbit/s ports 21 + 22:
Module position empty
99
10/100 Mbit/s ports 23 + 24:
Module position empty
F
Temperature range extended: -40 °C to +85 °C, conformal coating
C
Voltage range, power supply
unit 1:
18 VDC to 60 VDC
G
Voltage range, power supply
unit 2:
77 VDC to 300 VDC or 90 VAC to 265 VAC
H
Certifications:
CE, UL 508, GL, IEC 61850, IEEE 1613 Substation, EN
50121-4 Railway (along track)
P
Software variant:
Professional
Table 4: Example of the product designation of a MACH 1000 with 2 Gigabit ports:
MACH 1030- CC TT MM JJ NN VV UU LL GG ZZ TT 99 99 F C G H P
Release 02 10/10
21
2
Assembly and start-up
The devices have been developed for practical application in a harsh
industrial environment. The installation process is correspondingly simple.
On delivery, the device is ready for operation.
The following procedure has been proven to be successful for the assembly
of the device:
Unpacking and checking
Installing the SFP modules (optional)
Connecting the power unit connections for supply voltage and
signal contact
Installing the device and grounding
Startup
Connecting the data lines
2.1
Installing the device
2.1.1
Unpacking and checking
Check that the contents of the package are complete (see page 49
“Scope of delivery”).
Check the individual parts for transport damage.
2.1.2
Installing the SFP modules (optional)
Figure 7: 1 - Fast EHTERNET fiber optic SFP module
2 - Gigabit ETHERNET fiber optic SFP module
Before attaching an SFP module, first remove the protective cap over the
socket.
Push the SFP module with the lock closed into the socket until it latches
audibly in place.
Note: Only use Hirschmann SFP modules (see page 50 “Accessories”).
1
2
Release 02 10/10
2.1.3
Connecting the power unit connections
for supply voltage and signal contact
Connect the power supply and signal lines.
Note: Note the safety instructions (see on page 4 “Supply voltage”)
and only connect a supply voltage that corresponds to the type
plate of your device. Make sure that the contact load capability of
the signal contact is not exceeded (see on page 44 “Technical
data”).
Connecting the supply voltage
Connecting the supply voltage:
For device types with power units of the type “C” or “G” (voltage supply
terminal connection) via a 3-pin spring-loaded terminal, the signal
contact is connected via a 2-pin spring-loaded terminal to the power
units (power unit 1 and/or power unit 2, depending on the device
variant) on the back of the MACH1000 device.
For device types with power units of the type “L” or “M” (voltage supply
plugged connection) via a 3-pin terminal block with screw locking, the
signal contact is connected via a 2-pin terminal block (1 or 2 blocks,
depending on the device variant) on the back of the MACH1000
device.
Figure 8: MACH 1000, back of device, terminal voltage connection
1 - Supply voltage
2 - Power unit 2 (optional)
3 - Signal contact
4 - Power unit 1
4
5
3
2
1
Relay 1
3
2
1
4
5
N L
1
4
3
4
5
3
2
1
Relay 2
3
2
1
4
5
N L
1
2
3
Release 02 10/10
23
Figure 9: MACH 1000 device variants (back of device), plugged voltage connection
1 - Power unit 1
2 - Power unit 2 (optional)
3 - 2 Terminal blocks for signal contact
4 - 2 Terminal blocks for supply voltage
5 - 1 Terminal block for supply voltage
6 - 1 Terminal block for signal contact
For device variants without PoE: The supply voltage in
MACH 1000 device types can be connected redundantly with two power
units. Both inputs are uncoupled.
The supply voltage is electrically isolated from the housing.
MACH 1000 devices without PoE
MACH 1000 device variants without PoE (Power over Ethernet) are,
depending on the device type, equipped with one or two power units of
the following type:
Type “C” (18 VDC to 60 VDC, see product code items 36 and 37 in
table 3 and/or
Type “G” (77 VDC to 300 VDC or 90 VAC to 265 VAC, see product
code items 36 and 37 in table 3
or
Type “L” (18 VDC to 60 VDC, see product code items 36 and 37 in
table 3 and/or
Type “M” (77 VDC to 300 VDC or 90 VAC to 265 VAC, see product
code items 36 and 37 in table 3.
Relay 2
3
2
1
4
5
N L
Relay 2
3
2
1
4
5
N L
LS DA
USB
V.24
MACH 1000
2
1
LS DA
3
4
9
10
P
StandBy
RM
FAULT
R1 R2
5
6
7
8
13
14
11
12
17
18
15
16
21
22
19
20
25
26
23
24
3
4
5
6
LS DA
LS DA
LS DA
USB
V.24
P
StandBy
RM
FAULT
R1 R2
2
1
-/N +/L
-/N +/L
4
3
5
6
-/N +/L
2
1
4
3
Release 02 10/10
Note: For device variants without PoE: For device variants with two power
units, if there is non-redundant voltage supply, the device reports the
failure of one supply voltage. You can prevent this message by applying
the supply voltage via both inputs, or by changing the configuration in the
Management.
MACH 1000 devices with PoE
The MACH 1000 device variants MAR1022-..., MAR1032-...,
MAR1132-... and MAR 1132-... support Power over Ethernet (PoE) in
accordance with IEEE 802.3af. They allow the connection and remote
supply of, for example, IP telephones (Voice over IP), webcams, sensors,
printer servers and WLAN access points via 10BASE-T/100BASE-TX.
With PoE, these terminal devices are powered by the twisted-pair cable.
The MACH 1000 devices with PoE have 2*2 twisted pair ports TX
10/100 Mbit/s, depending on the device variant, as RJ45 or M12 sockets
for connecting network segments or PoE terminal devices (PD, Powered
Device) for all IEEE802.3af classes up to a maximum power output of
15.4 W.
The current is supplied on wire pairs transmitting the signal; the individual
ports are not electrically insulated from each other.
The following conditions are met in accordance with IEEE 802.3af:
Endpoint PSE
Alternative A
MACH 1000 device variants without PoE (Power over Ethernet) are
equipped with two power units.
Power unit 2 is a PoE power unit, see product code item 37 in table 3.
You can choose the connections to power unit 1, see product code
item 36 in table 3.
MACH 1000 devices with terminal connection voltage
supply
MACH 1000 devices with product code “C” and “G” have a terminal
connection for the supply voltage, see product code items 36 and 37 in
table 3.
Warning: Never insert sharp objects (small screwdrivers, wires,
etc.) into the field connection terminals for the supply voltage,
and do not touch the terminals! There is the risk of an electric
shock.
Release 02 10/10
25
Note: Observe the permitted voltage ranges for devices with
type „T“ certifications (EN 50155 Railway (train), see product
code item 38 in table 3).
Power supply type G and M: nominal voltage 110 VDC
Power supply type C and L: nominal voltage 36 VDC
To insert the cable, you open the terminal lock by positioning the
screwdriver as illustrated below and pressing on the lever.
Figure 10: Connecting the supply voltage via the 3-pin spring-loaded terminal
1 - Field connection terminal for supply voltage
2 - Terminal lock
First connect the protective conductor to the protective conductor
terminal.
Connect the supply voltage via the 3-pin spring-loaded terminal. Pay
attention to the +/L and -/N connections.
If the neutral conductor or the minus terminal of the supply voltage is
not grounded, install a suitable fuse in the input line.
3
2
1
-/N +/L
1
2
Release 02 10/10
Figure 11: Back of MACH 1000 device with power unit “C”,
DC voltage (18...60 VDC)
Connecting
1 - Supply voltage
2 - Signal contact
Figure 12: Back of MACH 1000 device with power unit “G”,
AC voltage 90-265 VAC (top image) or
DC voltage 77-300 VDC (bottom image)
Connecting
1 - Supply voltage
2 - Signal contact
3 - External fuse for supply voltages > 125 VDC
4
5
3
2
1
Relay
3
2
1
4
5
-
+
-
+
2
1
4
5
Relay
4
5
G
4
5
Relay
4
5
3
2
1
3
2
1
-/N +/L
3
2
1
3
2
1
-/N +/L
2
1
3
-
+
2
1
Release 02 10/10
27
For type “G” power units, you can choose between connecting DC or AC
voltage.
For supply voltages > 125 VDC:
Install a suitable external fuse in the supply voltage input line of the
plus terminal (see fig. 12).
MACH 1000 devices with plugged connection voltage
supply
MACH 1000 devices with product code “L” and “M” have a plugged
connection for the supply voltage, see product code items 36 and 37 (see
table 3).
Figure 13: Location of the supply voltage plugged connection
1 - Supply voltage
2 - Signal contact
3 - Voltage range L: 18-60 VDC
4 - Voltage range M: 77-300 VDC or 90-265 VAC
Warning: Never insert sharp objects (small screwdrivers, wires,
etc.) into the terminal block for the supply voltage, and do not
touch the terminals! There is the risk of an electric shock.
Connection
Type “C”
Type “G” VDC
Type “G” VAC
, pin 1
Protective conductor
Protective conductor
Protective conductor
-/N, pin 2
Minus terminal of the
supply voltage
Minus terminal of the
supply voltage
Neutral conductor
+/L, pin 3
Plus terminal of the
supply voltage
Plus terminal of the
supply voltage
“Phase” supply
voltage
Table 5: Pin assignment of spring-loaded terminal for voltage supply
1
2
3
-/N +/L
1
2
4
Release 02 10/10
Note: Note the safety instructions (see on page 4 “Supply
voltage”) and only connect a supply voltage that corresponds to
the type plate of your device. Make sure that the contact load
capability of the signal contact is not exceeded (see on page 44
“Technical data”).
Note: Observe the permitted voltage ranges for devices with
type „T“ certifications (EN 50155 Railway (train), see product
code item 38 in table 3).
Power supply type G and M: nominal voltage 110 VDC
Power supply type C and L: nominal voltage 36 VDC
Note: Relevant for North America:
The tightening torque of the terminal block screws is 3 lb in. (0.34 Nm).
Pull the terminal block(s) off the switch and connect the voltage supply
lines as follows:
First connect the protective conductor to the protective conductor
terminal.
Connect the supply voltage via the 3-pin terminal block. Pay attention
to the +/L and -/N connections.
If the neutral conductor or the minus terminal of the supply voltage is
not grounded, install a suitable fuse in the input line.
Figure 14: Back of MACH 1000 device with power unit “L”,
DC voltage (18...60 VDC)
Connecting
1 - Supply voltage
2 - Signal contact
1
2
Relay
Release 02 10/10
29
Figure 15: Back of MACH 1000 device with power unit “M”,
AC voltage 90-265 VAC (right image) or
DC voltage 77-300 VDC (left image)
Connecting
1 - Supply voltage
2 - Signal contact
3 - External fuse for supply voltages > 125 VDC
For type “M” power units, you can choose between connecting DC or AC
voltage.
For supply voltages > 125 VDC:
Install a suitable external fuse in the supply voltage input line of the
plus terminal (see fig. 12).
Note: The terminal blocks for devices with power unit type “M” (type “L”)
are coded to prevent them from being accidently connected to devices
with power unit type “L” (type “M”).
Connecting the PoE supply voltage (optional)
The devices connected are supplied with PoE voltage (48 V DC safety low
voltage) via an internal power supply unit.
The twisted-pair cables at Fast Ethernet ports 1 to 4 of the device are
supplied with PoE voltage via the wire pairs transmitting the signal
(phantom voltage) for both RJ45 and M12.
“FAULT” signal contact
Depending on the MACH 1000 device variant (equipped with one or two
power units), you have either one or two signal contacts.
Connection
Type “L”
Type “M” VDC
Type “M” VAC
, pin 1
Protective conductor
Protective conductor
Protective conductor
-/N, pin 2
Minus terminal of the
supply voltage
Minus terminal of the
supply voltage
Neutral conductor
+/L, pin 3
Plus terminal of the
supply voltage
Plus terminal of the
supply voltage
“Phase” supply
voltage
Table 6: Pin assignment of spring-loaded terminal for voltage supply
1
2
Relay
-/N +/L
-/N +/L
G
Relay
1
2
3
Release 02 10/10
The signal contact monitors proper functioning of the device, thus
enabling remote diagnostics. You can specify the type of function
monitoring in the Management.
Pin assignment: for MACH 1000 devices
–
with terminal voltage supply (see fig. 11), (see fig. 12)
–
with plugged voltage supply (see fig. 14), (see fig. 15)
You can also use the Management to switch the signal contact
manually and thus control external devices.
A break in contact is used to report the following conditions via the
potential-free signal contact (relay contact, closed circuit):
The failure of at least one supply voltage.
A continuous malfunction in the device.
The loss of connection at at least one port. The report of the link status
can be masked by the Management for each port. In the delivery state,
link status monitoring is deactivated.
The loss of ring redundancy reserve.
A detected error during the self-test.
Incorrect configuration of the HIPER-Ring or ring coupling.
Permitted temperature range exceeded/not reached.
The following condition is also reported in RM mode:
Ring redundancy reserve is available. On delivery, there is no ring
redundancy monitoring.
Note: You can use the signal contact functions when the voltage supply
is connected. If there is redundant voltage supply, but this is turned off,
there is a contact interruption at the corresponding signal contact.
2.1.4
Installing the device and grounding
Note: The shielding ground of the connectable industrial twisted pair lines is
connected to the front panel as a conductor.
Mounting in a 19“ rack
The devices are designed to be mounted in a 19" rack.
Make sure there is sufficient ventilation. If necessary, provide a fan for
the 19" rack. This will prevent the basic devices from overheating.
Measure the depth of the 19" rack so as to allow the main cable, and
any power supply cables, to be fitted from the back, and the data
cables to be fitted from the front.
If you are operating the device in a 19" switch cabinet, you must install
sliding/mounting rails (not included in the delivery) to hold the weight of
the device.
Release 02 10/10
31
Warning!
If the device is installed in a 19" switch cabinet without sliding/
mounting rails, increased vibration can cause damage to the
device and/or its modules.
For more information on sliding/mounting rails and how to install them,
please contact your switch cabinet manufacturer.
Install the sliding/mounting rails in the 19" switch cabinet as instructed
by the manufacturer, and make sure the device is resting on both rails.
On delivery, two brackets are attached to the sides of the device (see
figure below).
Fasten the device by screwing the brackets to the switch cabinet.
Figure 16: Mounting in the switch cabinet
Warning!
When installing the device, make sure the ventilation slots
remain unobstructed, as otherwise the device can overheat and
be damaged.
Note: Fasten the device with two additional brackets at the back of the
switch cabinet when operating it in environments with strong vibrations
(see on page 50 “Accessories”, not included in the delivery).
Vertical mounting on the wall
Use the pre-mounted brackets included in the delivery as shown in the
following figure (see fig. 17).
Attach two additional brackets to the device (see on page 50
“Accessories”, not included in the delivery) as shown in the following
figure (see fig. 17).
Fasten the device by screwing the brackets to the wall.
Warning!
When installing the device, make sure the ventilation slots
remain unobstructed, as otherwise the device can overheat and
be damaged.
Note: The shielding ground of the connectable industrial twisted pair lines
is connected to the front panel as a conductor.
LS DA
USB
V.24
MACH 1000
2
1
LS DA
3
4
9
10
P
StandBy
RM
FAULT
R1 R2
5
6
7
8
13
14
11
12
17
18
15
16
21
22
19
20
25
26
23
24
LS DA
LS DA
LS DA
LS DA
MACH 1000
Release 02 10/10
33
Figure 18: MACH 1000, dimensions of device variants
31,75
218,25
31,75
53,2
465,9
482,6
444
44,2
313,5
482,6
465,9
31,8
44
342
352,5
Release 02 10/10
Grounding the device
The device is grounded as follows:
for MACH 1000 devices with terminal connection voltage supply
via a separate spring-loaded terminal.
This is located at the 1 or 2 power supply modules on the back of the
device, at pin 1 (see fig. 11 and fig. 12).
for MACH 1000 devices with plugged connection voltage supply:
via a ground connection on the front panel of the device (see fig. 13).
Connect the protective conductor before you set up the other
connections. When removing the connections, you remove the
protective conductor last.
Connect both protective conductors if your device is equipped with two
power supply units.
2.1.5
Startup procedure
When you connect the supply voltage, you start up the device.
2.1.6
Connecting the data lines
You can connect terminal devices and other segments at the ports of the
device via twisted pair cables or F/O cables.
Install the data lines according to your requirements.
Note: To optimize the data flow, connect the main data traffic to ports 1 and
4.
10/100 Mbit/s twisted pair connection
10/100 Mbit/s ports (RJ45 socket) enable the connection of terminal
devices or independent network segments according to the IEEE 802.3
100BASE-TX and 10BASE-T standard.
These ports support:
Autonegotiation
Autopolarity
Autocrossing (if autonegotiation is activated)
100 Mbit/s half-duplex mode, 100 Mbit/s full duplex mode
10 Mbit/s half-duplex mode, 10 Mbit/s full duplex mode
State on delivery: autonegotiation activated.
The socket housing is electrically connected to the front panel.
Pin assignment of the RJ45 socket:
One line pair: pin 3 and pin 6
One line pair: pin 1 and pin 2
Remaining pins: not used.
Release 02 10/10
35
Figure 19: Pin assignment of a TP/TX interface in MDI-X mode, RJ45 socket
Note: In substation applications, the RJ45 ports are used to connect to
additional communication devices such as routers or telecommunication
multiplexers that are installed in close proximity to the device (i.e. less
than 3 meters away). It is not recommended to use these ports for
connection to field devices across longer distances which could cause a
significant increase in the ground potential (Ground Potential Rise GPR,
i.e. more than 2500 V).
10/100/1000 Mbit/s twisted pair connection
1000 Mbit/s twisted pair ports (RJ45 sockets) facilitate the connection of
terminal devices or independent network segments according to the IEEE
802.3-2000 (ISO/IEC 8802-3:2000) 1000BASE-TX standard.
These ports support:
Autonegotiation
Autopolarity
Autocrossing (if autonegotiation is activated)
1000 Mbit/s full duplex
100 Mbit/s half duplex, 100 Mbit/s full duplex,
10 Mbit/s half duplex, 10 Mbit/s full duplex.
Default settings: autonegotiation.
The socket housing is electrically connected to the front panel.
The pin assignment corresponds to MDI-X.
Figure 20: Pin assignment of the 1000 Mbit/s twisted pair interface
Note: In general, you should adhere to the following recommendations for
data cable connections using copper in environments with high electrical
interference levels:
n.c.
8
n.c.
7
TD-
6
n.c.
5
n.c.
4
3
TD+
2
RD-
1
RD+
8
7
6
5
4
3
2
1
BI_DC-
BI_DC+
BI_DA-
BI_DD-
BI_DD+
BI_DA+
BI_DB-
BI_DB+
Release 02 10/10
Keep the length of the data cables as short as possible - ideally max.
3m long. You should not use any copper data cables for the data
transmission between buildings.
Power supply and data cables should not run parallel over longer
distances, and ideally they should be installed in separate cable
channels. If the inductive coupling has to be reduced, the power
supply and data cables should cross at a 90° angle.
You may also choose to use shielded cables. Ground the cable
shielding at one point in order to avoid causing a ground loop.
10/100 Mbit/s twisted pair connection PoE
10/100 Mbit/s ports (RJ45 or M12 sockets) enable the connection of
terminal devices or independent network segments according to the IEEE
802.3 100BASE-TX / 10BASE-T and IEEE 802.3af (Power over
ETHERNET on data lines) standards. These ports support:
Autonegotiation
Autopolarity
Autocrossing (if autonegotiation is activated)
100 Mbit/s half-duplex mode, 100 Mbit/s full duplex mode
10 Mbit/s half-duplex mode, 10 Mbit/s full duplex mode
Power over ETHERNET (PoE)
State on delivery: autonegotiation activated.
The socket housing is electrically connected to the front panel.
The PoE voltage is input via the wire pairs transmitting the signal
(phantom voltage).
Figure 21: Pin assignment of a TP/TX interface in MDI-X mode, RJ45 socket
Use a shielded CAT5 cable.
Use a shielded 4-pin M12 plug.
Figure
Pin
Function
PoE (PSE)
1
TX+
Transmit Data +
+
2
RX+
Receive Data +
-
3
TX-
Transmit Data -
+
4
RX-
Receive Data -
-
Chassis
Shield
Table 7: Pin assignment of the TP/TX interface for PoE (M12 socket)
n.c.
8
n.c.
7
TD-
6
n.c.
5
n.c.
4
3
TD+
2
RD-
1
RD+
Release 02 10/10
37
Connect the cable shield to the connector housing.
The patch cables for operating the device are shown in the following
figure:
Figure 22: Patch cables for operating the device
(1) - Connection cables M12-4 on M12-4, crossed
(2) - Connection cables M12-4 on M12-4, 1 to 1
(3) - Connection cables M12-4 on RJ45, crossed
(4) - Connection cables M12-4 on RJ45, 1 to 1
(5) - M12 (MDI)
(6) - Shield
(7) - M12 (MDI)
(8) - M12 (MDI-X via autocrossing port)
(9) - RJ45, MDI (terminal device)
(10) - RJ45, MDI-X (Switch)
RX+
TX+
RX-
TX-
1
2
3
4
TX+
RX+
TX-
RX-
1
2
3
4
TX+
RX+
TX-
RX-
1
2
3
4
TX+
RX+
TX-
RX-
1
2
3
4
TX+
TX-
RX+
RX-
1
2
3
6
TX+
RX+
TX-
RX-
1
2
3
4
RX+
RX-
TX+
TX-
1
2
3
6
TX+
RX+
TX-
RX-
1
2
3
4
(1)
(5)
(7)
(2)
(5)
(8)
(3)
(5)
(9)
(4)
(5)
(10)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
Release 02 10/10
10 Mbit/s F/O connection
10 MBit/s F/O ports (ST connectors) enable the connection of terminal
devices or independent network segments in compliance with the IEEE
802.3 10BASE-FL standard.
Full or half duplex mode
State on delivery: full duplex FDX
100 Mbit/s F/O connection
100 MBit/s F/O ports (ST, DSC, MTRJ or SFP slot) enable the connection
of terminal devices or independent network segments in compliance with
the IEEE 802.3 100BASE-FX standard. These ports support:
Full or half duplex mode
State on delivery: full duplex FDX
Note: Make sure that the LH ports are only connected with LH ports, SM
ports are only connected with SM ports, and MM ports only with MM ports.
1 Gbit/s F/O connection
1 GBit/s F/O ports (SFP slot) enable the connection of terminal devices or
independent network segments in compliance with the IEEE 802.3-2000
(ISO/IEC 8802-3:2000) 1000BASE-SX or 1000BASE-LX standards.
These ports support:
Autonegotiation
State on delivery: autonegotiation activated.
Note: Make sure that the LH ports are only connected with LH ports, SX
ports are only connected with SX ports, and LX ports only with LX ports.
Note: With the MACH 1030 with two Gbit/s F/O ports, these ports are
combo ports (SFP/RJ45). You can use either the SFP slot or the RJ45
socket to connect data lines. If both are used, the assigned SFP slot
switches off the related RJ45 port.
2.2
Display elements
After the operating voltage is set up, the software starts and initializes itself.
Afterwards, the device performs a self-test. During this process, various
LEDs light up. The process takes around 60 seconds.
Release 02 10/10
39
Figure 23: Display elements of MACH 1000, device variants with ports on the front
1 - Device status display elements
2 - Port status display elements
Figure 24: Display elements of MACH 1000, device variants with ports on the back
1 - Device status display elements
2 - Port status display elements for up to 4 Gigabit Ethernet ports and
up to 20 Fast Ethernet ports
3 - Diagnosis port with display element
Device state
These LEDs provide information about conditions which affect the
operation of the whole device.
P - Power (green/yellow LED)
Glowing green
Device variants with 2 power supply units: Both supply
voltages are on
Device variants with 1 power supply unit: Supply voltage is on
Glowing yellow
Device variants with 2 power supply units: There is only one
supply voltage (P1 or P2) on
Not glowing
Supply voltage is too low
RM - Ring Manager (green/yellow LED)
Glowing green
RM function active, redundant port disabled
Glowing yellow
RM function active, redundant port enabled
Not glowing
RM function not active
Flashing green
Incorrect configuration of the HIPER-Ring (e.g. the ring is not
connected to the ring port).
Sb StandBy - stand-by mode (green LED)
Glowing green
Stand-by mode enabled.
Not glowing
No stand-by mode.
3
4
5
6
LS DA
LS DA
USB
V.24
MACH 1000
2
1
P
StandBy
RM
FAULT
R1 R2
1
2
P
StandBy
RM
FAULT
R1 R2
ETHERNET Service Port
1
3
5
7
9
11 13 15 17 19 21 23
2
4
6
8
10 12 14 16 18 20 22 24
2
1
3
Release 02 10/10
Applies to software releases previous to 06.0.00:
Applies to software release 06.0.00 and higher:
Applies to software releases previous to 06.0.00:
Applies to software release 06.0.00 and higher:
If the manual adjustment is active on the signal contact, then the error
display is independent of the setting of the signal contact.
Port state
The green and yellow LEDs at the individual port display port-related
information. During the boot phase, these LEDs are used to display the
status of the boot procedure.
RM and Stand-by - display saving processes of the AutoConfiguration Adapter (ACA)
Flashing alternately
Error during saving process.
LEDs flash synchronously, two
times a second
Loading configuration from the ACA.
LEDs flash synchronously,
once a second
Saving the configuration in the ACA.
LED
Display
Color
Activity
Meaning
FAULT Signal contact 1
Red
Lights up
The signal contact is open, it is
reporting an error.
None
Signal contact is closed, it is not
reporting an error.
LED
Display
Color
Activity
Meaning
FAULT Signal contact 1
Red
Lights up
The signal contact is open, it is
reporting an error.
None
Signal contact is closed, it is not
reporting an error.
Duplicate IP
detection
Red
Flashing 4 times a
period
Reports an IP conflict.
LED
Display
Color
Activity
Meaning
R1
Signal contact 1
Yellow Lights up
The signal contact is closed in
manual operation.
None
The signal contact is open in
manual operation.
R2
Signal contact 2
Yellow Lights up
The signal contact is closed in
manual operation.
None
The signal contact is open in
manual operation.
LED
Display
Color
Activity
Meaning
R1
Signal contact 1
Yellow Lights up
The signal contact is open.
None
The signal contact is closed.
R2
Signal contact 2
Yellow Lights up
The signal contact is open.
None
The signal contact is closed.
Release 02 10/10
41
2.3
Basic set-up
The IP parameters must be entered when the device is installed for the first
time. The device provides 6 options for configuring IP addresses:
Entry via V.24 connection
Entry using the HiDiscovery protocol
Configuration via BOOTP
Configuration via DHCP
Configuration via DHCP Option 82
Auto Configuration Adapter
Further information on the basic settings of the device can be found in the
"Basic Configuration" user manual on the CD ROM.
Default settings
IP address: The device looks for the IP address using DHCP
Password for management:
Login: user; password: public (read only)
Login: admin; password: private (read and write)
Parameters that can be set via the management are set to pre-defined
values in accordance with the MIB
V.24 data rate: 9,600 Baud
Ring redundancy: disabled
Ethernet ports: link status is not evaluated (signal contact)
Optical 100 Mbit/s ports: 100 Mbit/s, full duplex
All other ports: autonegotiation
Ring manager disabled
Stand-by coupling: disabled
Port 4 = control port, port 3 = coupling port for red. Ring coupling
USB interface
The USB socket has an interface for the local connection of an
AutoConfiguration Adapter (part number ACA 21-USB see on page 50
“Accessories”). It is used for saving/loading the configuration and for
loading the software.
LS - data, link status (one green/yellow LED or one green and one yellow LED)
Not glowing
No valid connection.
Glowing green
Valid connection.
Flashing green (1 time a period) Port is switched to stand-by.
Flashing green (3 times a
period)
Port is switched off.
Flashing yellow
Data reception.
Release 02 10/10
V.24 interface (external management)
The V.24 interface is an RJ11 socket.
The V.24 interface is a serial interface which allows you to connect the
following devices locally:
An external management station (VT100 terminal or PC with
appropriate terminal emulation). This enables you to set up a
connection to the Command Line Interface (CLI) and to the system
monitor.
An AutoConfiguration Adapter ACA 11
The socket housing is electrically connected to the front panel of the
device.
The V.24 interface is not electrically isolated from the supply voltage.
Figure 25: Pin assignment of the V.24 interface and the DB9 connector
Note: You will find the order number for the terminal cable, which is
ordered separately, in the Technical Data chapter (see on page 44
“Technical data”).
You will find a description of the V.24 interface in the “Basic Configuration
User Manual” on the CD-ROM.
Figure
Pin
Function
1
VCC (VBus)
2
- Data
3
+ Data
4
Ground (GND)
Table 8:
Pin assignment of the USB interface
VT 100 terminal settings
Speed
9,600 Baud
Data
8 bit
Stopbit
1 bit
Handshake
off
Parity
none
1 2
4
3
1
1
8
5
6
2
3
5
1
2
3
4
5
6
CTS
n.c.
TX
GND
RX
RTS
RJ11
DB9
RJ11
DB9
Release 02 10/10
43
2.4
Disassembling the device
To detach the device from the switch cabinet or the wall, remove the
screws from the brackets on the device.
LS DA
USB
V.24
MACH 1000
2
1
LS DA
3
4
9
10
P
StandBy
RM
FAULT
R1 R2
5
6
7
8
13
14
11
12
17
18
15
16
21
22
19
20
25
26
23
24
LS DA
LS DA
LS DA
LS DA
MACH 1000
Release 02 10/10
3
Technical data
General technical data
Dimensions
W × D × H
MAR10...
MAR11... (deeper chassis structure)
448 × 310 × 44 mm
(without brackets)
448 × 345 × 44 mm
(without brackets)
Weight (incl.
redundant
power unit or
PoE power unit)
MAR1020-... fully equipped
max. 4.6 kg
MAR1030-... fully equipped
max. 4.7 kg
MAR1120-... fully equipped
(incl. redundant power unit)
max. 5.4 kg
MAR1130-... fully equipped
(incl. redundant power unit)
max. 5.5 kg
MAR1122-... fully equipped
max. 5.5 kg
MAR1132-... fully equipped
max. 5.6 kg
MAR1022-... fully equipped
max. 4.7 kg
MAR1032-... fully equipped
max. 4.8 kg
Weight
MAR1020-... basic device
approx. 3.9 kg
MAR1030-... basic device
approx. 4.0 kg
MAR1120-... basic device
approx. 4.7 kg
MAR1130-... basic device
approx. 4.8 kg
MAR1122-... basic device
approx. 5.1 kg
MAR1132-... basic device
approx. 5.2 kg
MAR1022-... basic device
approx. 4.3 kg
MAR1032-... basic device
approx. 4.4 kg
Optional PoE power unit
Optional second power unit
Per 6 ports (3 modules)
Per M12 module
approx. 0.39 kg
additional approx. 0.3 kg
additional approx. 0.1 kg
additional approx. 0.09 kg
Power supply
Power unit type “G”
and “M”
Nominal voltage AC
Voltage range AC
Nominal voltage DC
Voltage range DC
Connection type “G”
Connection type “M”
Power failure bypass
100 - 240 V, 50 - 60 Hz
90 - 265 V, 47 - 63 Hz
110 - 250 V (devices with type „T“
certification: 110 V)
77 - 300 V
Spring-loaded terminal for copper
wire with cross-section AWG 20-12
(0.5 to 3.0 mm2) and stripping length
12 mm
3-pin terminal block
> 20 ms at 230 V AC
Power unit type “C”
and “L”
Fuse
Nominal voltage DC
Voltage range DC
Connection type “C”
Connection type “L”
Power failure bypass
Fuse
Built into the power unit
24 - 48 V (devices with type „T“
certification: 36 V)
18 - 60 V
Spring-loaded terminal for copper
wire with cross-section AWG 20-12
(0.5 to 3.0 mm2) and stripping length
12 mm
3-pin terminal block
> 10 ms at 20.4 V DC
Built into the power unit
Release 02 10/10
45
EMC and immunity
Power supply for
device variants
with PoE
Input voltage DC
Input voltage AC
Output voltage
77 V … 300 V
(110 V … 250 V -30% … +25%)
90 V … 265 V
(110 V … 230 V -20% … +15%)
48 V DC ± 5%
“FAULT”
signal contact
Nominal value for AC
Nominal value for DC
Connection type
2 A at 230 V AC (500 VA)
2 A at 30 V DC
0.2 A at 125 V DC
0.1 A at 250 V DC
Spring-loaded terminal for copper
wire with cross-section AWG 20-12
(0.5 to 3.0 mm2) and stripping length
12 mm
Environment
Storage temperature
(ambient air)
Humidity
Air pressure
Standard: -40 °C to +70 °C
Extended: -40 °C to +85 °C
5% to 95% (non-condensing)
Up to 2000 m (795 hPa), higher
altitudes on request
Operating
temperature
Default (surrounding air)
Extended (surrounding air)
0 °C to +60 °C
-40 °C to +85 °C abcd
Contamination
level
2
Protection classes Laser protection
Protection class
Class 1 according to EN 60825-1
(2001)
IP 30
a.
For devices with an extended temperature range equipped with more than 14 F/O ports, the
maximum operating temperature is reduced by 1K for each additional F/O port. Example:
MACH 1000 device with extended temperature range and 20 F/O ports: Operating
temperature = -40 °C to +79 °C.
b.
MACH 1000 device equipped with “GG” Fast Ethernet modules (Singlemode Long Haul FX
DSC 200 km ): 0 °C to +60 °C
c.
-40 °C to + 70 °C for devices with PoE, devices with FL ports and devices with 4 Gigabit
Ethernet ports
d.
Relevant for North America: max. surrounding air temperature: +70°C
EMC interference
immunity
IEC/EN 61850-
3:2002 EMI TYPE
tests, test in comp.
with
Description
Test level
IEC/EN 61000-4-2
Electrostatic discharge
Contact discharge
Air discharge
+/- 8 kV
+/- 15 kV
IEC/EN 61000-4-3
Electromagnetic field
80 - 2,700 MHz
20 V/m
IEC/EN 61000-4-4
Fast transients (burst)
DC power line
AC power line
Data line
+/- 4 kV (2.5 kHz)
+/- 4 kV (2.5 kHz)
+/- 4 kV (2.5 kHz)
Release 02 10/10
IEC/EN 61000-4-5
Voltage surges
DC power line
AC power line
Data line
+/- 2 kV line / earth; +/- 1 kV line / line
+/- 4 kV line / earth; +/- 2 kV line / line
+/- 4 kV line / earth
IEC/EN 61000-4-6
Line-conducted interference
voltages
150 kHz - 80 MHz
10 V
IEC/EN 61000-4-12 Damped vibration
DC power line
AC power line
Data line
+/- 2.5kV line / earth; +/- 1kV line / line
+/- 2.5kV line / earth; +/- 1kV line / line
+/- 2.5kV line / earth; +/- 1kV line / line
IEC 60255-5
Dielectric strength
DC power line; power unit type C, L
AC power line; power unit type G,
M
DC power line; power unit type G,
M
Signal contact type C, L and G, M
500 VAC
2000 VAC
2000 VAC
2000 VAC
EMC interference
immunity
IEEE 1613:2009
EMI TYPE tests,
test in comp. with
Description
Test level
IEEE C37.90.3
Electrostatic discharge
Contact discharge
Air discharge
+/- 8 kV
+/- 15 kV
IEEE C37.90.2
Electromagnetic field
80 - 1,000MHz
35 V/m (peak)
IEEE C37.90.1
Fast transients (burst)
DC power line
AC power line
Data line
+/- 4 kV (2.5 kHz)
+/- 4 kV (2.5 kHz)
+/- 4 kV (2.5 kHz)
IEEE C37.90.1
Damped vibration
DC power line
AC power line
Data line
+/- 2.5kV line / earth; +/- 1kV line / line
+/- 2.5kV line / earth; +/- 1kV line / line
+/- 2.5kV line / earth; +/- 1kV line / line
IEEE C37.90
H.V. impulse
DC power line
AC power line
+/- 5 kV line / earth
+/- 5 kV line / earth
IEEE C37.90
Dielectric strength
DC power line; power unit type C, L
AC power line; power unit type G,
M
DC power line; power unit type G,
M
Signal contact type C, L and G, M
500 VAC
2000 VAC
2000 VAC
2000 VAC
EMC interference
immunity
IEC/EN 61850-
3:2002 EMI TYPE
tests, test in comp.
with
Description
Test level
Release 02 10/10
47
Network range
EMC emitted interference
EN 55022
Class A
FCC 47 CFR Part
15
Class A
German Lloyd
Classification + Construction Guidelines VI-7-3 Part 1 Ed.2001
Environment type
tests, test in comp.
with
Description
Test level
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60068-2-6
IEC 60068-2-27
Cold
Dry heat
Relative humidity
Vibration, test Fc
Shock, test Ea
-40 °C, 16 hours
+85 °C, 16 hours
95 % (non condensing)
55 °C, 4 cycles
2- 9 Hz with 3 mm amplitude
1 g at 9 - 150 Hz
1.5 g at 200 - 500 Hz
15 g at 11 ms
TP port
Length of a twisted pair segment
max. 100 m / 328 ft (cat5e cable with 1000BASE-T)
Table 9:
TP port 10BASE-T / 100BASE-TX / 1000BASE-T
Product
code
Wave-
length
Fiber
System
attenuati
on
Expansion Fiber data
-FF
MM
820 nm
50/125 µm
0-9.5 dB
0-2.1 km
3.0 dB/km; 400 MHz*km
-FF
MM
820 nm
62.5/125 µm
0-12.5 dB 0-3.0 km
3.2 dB/km; 200 MHz*km
Table 10: F/O port 10BASE-FL
Product
code
Wave-
length
Fiber
System
attenuati
on
Expansion Fiber data
-JJ, -MM, -
NN
MM
1300 nm
50/125 µm
0-8 dB
0-5 km
1.0 dB/km, 800 MHz*km
-JJ, -MM, -
NN
MM
1300 nm
62.5/125 µm
0-11 dB
0-4 km
1.0 dB/km, 500 MHz*km
-VV, -UU
SM
1300 nm
9/125 µm
0-16 dB
0-30 km
0.4 dB/km; 3.5 ps/(nm*km)
-LL
LH
1550 nm
9/125 µm
7-29 dB
24-86 km
0.3 dB/km; 19 ps/(nm*km)
-GG
LH+ 1550 nm
9/125 µm
14-47 dB
67-176 km
0.25 dB/km; 19 ps/(nm*km)
Table 11: F/O port 100BASE-FX
Release 02 10/10
Product
code
M-FAST-
SFP-...
Wave
length
Fiber
System
attenuatio
n
Expansion Fiber data
-MM/LC... MM 1310 nm
50/125 µm
0-8 dB
0-5 km
1.0 dB/km, 800 MHz*km
-MM/LC... MM 1310 nm
62.5/125 µm 0-11 dB
0-4 km
1.0 dB/km, 500 MHz*km
-SM/LC... SM 1310 nm
9/125 µm
0-13 dB
0-25 km
0.4 dB/km; 3.5 ps/(nm*km)
-SM+/
LC...
SM 1310 nm
9/125 µm
10-29 dB
25-65 km
0.4 dB/km; 3.5 ps/(nm*km)
-LH/LC
SM 1550 nm
9/125 µm
10-29 dB
40-104 km
0.25 dB/km; 19 ps/(nm*km)
Table 12: Fiber port 100BASE-FX (SFP fiber optic Fast ETHERNET Transceiver)
Product
code
M-SFP-...
Wave
length
Fiber
System
attenuatio
n
Expansion Fiber data
-SX/LC...
MM 850 nm
50/125 µm
0-7.5 dB
0-550 m
3.0 dB/km, 400 MHz*km
-SX/LC...
MM 850 nm
62.5/125 µm 0-7.5 dB
0-275 m
3.2 dB/km, 200 MHz*km
-MX/LC... MM 1310 nm
50/125 µm
0-8 dB
2 km a
a.
Distances up to 3 km reachable, 1000 MHz*km (1300 nm)
1.0 dB/km, 500 MHz*km
-MX/LC
MM 1310 nm
62.5/125 µm 0-8 dB
1 km
1.0 dB/km, 500 MHz*km
-LX/LC...
MM 1310 nmb
b.
With F/O adapter compliant with IEEE 802.3-2002 clause 38 (single-mode fiber offset-
launch mode conditioning patch cord)
50/125 µm
0-11 dB
0-550 m
1.0 dB/km, 800 MHz*km
-LX/LC...
MM 1310 nm b 62.5/125 µm 0-11 dB
0-550 m
1.0 dB/km, 500 MHz*km
-LX/LC...
SM 1310 nm
9/125 µm
0-11 dB
0-20 km
0.4 dB/km; 3.5 ps/(nm*km)
-LX+/LC
SM 1310 nm
9/125 µm
5-20 dB
14-42 km
0.4 dB/km; 3.5 ps/(nm*km)
-LH/LC...
LH
1550 nm
9/125 µm
6-22 dB
24-72 km
0.25 dB/km; 19 ps/(nm*km)
-LH+/LC
LH
1550 nm
9/125 µm
15-30 dB
71-108 km
0.25 dB/km; 19 ps/(nm*km)
-LH+/LC
LH
1550 nm
9/125 µm
15-30 dB
71-128 km
0.21 dB/km (typical);
19 ps/(nm*km)
Table 13: Fiber port 1000BASE-FX (SFP fiber optic Gigabit ETHERNET
Transceiver)
Product code
M-SFP-BIDI...
Wave
length
TX
Wave
length
RX
Fiber
System
attenuat
ion
Expansio
n
Fiber data
Type A LX/LC EEC SM 1310 nm 1550 nm 9/125 µm 0-11 dB
0-20 km
0.4 dB/km,
3.5 ps/(nm*km)
Type B LX/LC EEC SM 1550 nm 1310 nm 9/125 µm 0-11 dB
0-20 km
0.25 dB/km,
19 ps/(nm*km)
Type A LH/LC EEC LH
1490 nm 1590 nm 9/125 µm 5-24 dB
23-80 km
0.25 dB/km,
19 ps/(nm*km)
Type B LH/LC EEC LH
1590 nm 1490 nm 9/125 µm 5-24 dB
23-80 km
0.25 dB/km,
19 ps/(nm*km)
Table 14: F/O port (bidirectional Gigabit ETHERNET SFP Transceiver)
Release 02 10/10
49
MM = Multimode, SM = Singlemode, LH = Singlemode Longhaul
Power consumption/power output
Scope of delivery
Name
Power
consumpti
on
Power output
Basic devices
MAR1020-... basic device (without Fast Ethernet modules)
7.5 W
25.6 Btu (IT)/h
MAR1030-... basic device (incl. 2 Gigabit Ethernet module
combo ports, without Fast Ethernet modules)
10.5 W
35.9 Btu (IT)/h
MAR 1x3y-4O... basic device (x = 0 or 1, y = 0 or 2)
11.5 W
39.2 Btu (IT)/h
MAR 1x3y-4T... basic device (x = 0 or 1, y = 0 or 2)
14.5 W
49.5 Btu (IT)/h
MAR 1x3y-OT... basic device (x = 0 or 1, y = 0 or 2)
13.0 W
44.4 Btu (IT)/h
Fast Ethernet modules
additionally for each Fast Ethernet FX module
2.0 W
6.9 Btu (IT)/h
additionally for each Fast Ethernet TX module
0.4 W
1.4 Btu (IT)/h
additionally for each PoE module
38.0 W
130.0 Btu (IT)/h
Examples
MAR1020-
99TTTTTTTTTTTTTTTTTTTTTTTTUG9HPHHXX.X
12.3 W
42.0 Btu (IT)/h
MAR1020-
99TTTTTTTTTTTTMMMMMMMMMMMMUG9HPHHXX.X
21.9 W
74.8 Btu (IT)/h
MAR1020-
99MMMMMMMMMMMMMMMMMMMMMMMMUG9HPHHXX.X
31.5 W
107.5 Btu (IT)/h
MAR1030-
CCTTTTTTTTTTTTTTTTTTTTTTTTUG9HPHHXX.X
15.3 W
52.2 Btu (IT)/h
MAR1030-
CCTTTTTTTTTTTTMMMMMMMMMMMMUG9HPHHXX.X
24.9 W
85.0 Btu (IT)/h
MAR1030-
CCMMMMMMMMMMMMMMMMMMMMMMMMUG9HPHHXX.
X
34.5 W
117.8 Btu (IT)/h
MAR1030-
4TMMMMMMMMMMMMMMMMMMMMMMMMUG9HPHHXX.X
38.5 W
131.4 Btu (IT)/h
MAR1032-4TTTRRMMMMMMMMMM
MMMMMMMMMMUGGHPHHXX.X, non-PD (powered device)
35.3 W
120.5 Btu (IT)/h
MAR1132-4OTTRRMMMMMMMMMM
MMMMMM9999UGGHPHHXX.X, non-PD (powered device)
28.3 W
96.6 Btu (IT)/h
MAR1032-4TTTRRMMMMMMMMMMMM
MMMMMMMMUGGHPHHXX.X, 4 x Class0-PD (powered
device)
111.3 W
380.5 Btu (IT)/h
MAR1132-4OTTRRMMMMMMMMMMMM
MMMM9999UGGHPHHXX.X, 4 x Class0-PD (powered device)
104.3 W
356.6 Btu (IT)/h
Device
Scope of delivery
MAR...
MAR... device
Installation user manual
CD-ROM
Release 02 10/10
Order numbers/product description
Combination options and device names (see table 3).
Accessories
Note: Please note that products recommended as accessories may have
characteristics that do not fully correspond to those of the corresponding
product. This may limit their possible usage in the overall system.
Name
Operating
temperature
(chassis)
Order number
AutoConfiguration Adapter ACA 21-USB
943 271-001
Terminal cable
943 301-001
3-pin terminal block high voltage interlock
(50 pieces)
943 845-008
3-pin terminal block low voltage interlock
(50 pieces)
943 845-011
Bracket for fastening the housing
943 943-001
Dust protection cap for RJ 45 sockets (50 pcs.)
943 936-001
Dust protection cap for SFP slots (25 pcs.)
943 942-001
HiVision Network Management software
943 471-100
OPC Server software HiOPC
943 055-001
Gigabit ETHERNET SFP Transceiver
M-SFP-SX/LC
0 °C to +60 °C
943 014-001
M - SFP - SX / LC EEC
-40 °C to +70 °C
943 896-001
M - SFP - MX / LC
0 °C to +60 °C
942 035-001
M-SFP-LX/LC
0 °C to +60 °C
943 015-001
M - SFP - LX / LC EEC
-40 °C to +70 °C
943 897-001
M - SFP - LX+ / LC
0 °C to +60 °C
942 023-001
M - SFP - LX+/ LC EEC
-40 °C to +70 °C
942 024-001
M-SFP-LH/LC
0 °C to +60 °C
943 042-001
M - SFP - LH / LC EEC
-40 °C to +70 °C
943 898-001
M-SFP-LH+/LC
0 °C to +60 °C
943 049-001
Fast ETHERNET SFP Transceiver
M-FAST SFP-MM/LC
0 °C to +60 °C
943 865-001
M-FAST SFP-MM/LC EEC
-40 °C to +70 °C
943 945-001
M-FAST SFP-SM/LC
0 °C to +60 °C
943 866-001
M-FAST SFP-SM/LC EEC
-40 °C to +70 °C
943 946-001
M-FAST SFP-SM+/LC
0 °C to +60 °C
943 867-001
M-FAST SFP-SM+/LC EEC
-40 °C to +70 °C
943 947-001
M-FAST SFP-LH/LC
0 °C to +60 °C
943 868-001
M-FAST SFP-LH/LC EEC
-40 °C to +70 °C
943 948-001
Bidirectional Gigabit ETHERNET SFP Transceiver
M-SFP-BIDI Type A LX/LC EEC
-40 °C to +70 °C
943 974-001
M-SFP-BIDI Type B LX/LC EEC
-40 °C to +70 °C
943 974-002
M-SFP-BIDI Type A LH/LC EEC
-40 °C to +70 °C
943 975-001
Release 02 10/10
51
Underlying norms and standards
The device has a certification based on a specific standard only if the
certification indicator appears on the housing.
However, with the exception of Germanischer Lloyd, ship certifications as
well as RINA certifications are only included in the product information
under www.beldensolutions.com.
M-SFP-BIDI Type B LH/LC EEC
-40 °C to +70 °C
943 975-002
M-SFP-BIDI Bundle LX/LC EEC (Type A + B)
-40 °C to +70 °C
943 974-101
M-SFP-BIDI Bundle LH/LC EEC (Type A + B)
-40 °C to +70 °C
943 975-101
Name
EN 61000-6-2:2005
Generic norm – immunity in industrial environments
EN 55022:2006 + A1:2007 IT equipment – radio interference characteristics
IEC/EN 60950-1:2006
Safety for the installation of IT equipment
EN 61131-2:2007
Programmable logic controllers
EN 50121-4:2006
Railway applications - EMC - emitted interference and interference
immunity for signal and telecommunication systems
EN 50155:2007
Railway applications - electronic systems in railway vehicles
FCC 47 CFR Part 15:2009 Code of Federal Regulations
Germanischer Lloyd
Ship Applications - Classification and Construction Guidelines VI-
7-3 Part 1 Ed.2003
cUL 508:1998
Safety for Industrial Control Equipment
EN 61850-3
Communications networks and systems in stations
IEEE 1613
Standard Environment and Testing Requirements for
Communication Networking Devices in Electric Power Substations
Table 15: List of norms and standards
IEEE 802.1 D
Switching, GARP, GMRP, Spanning Tree
IEEE 802.1 D-1998
Media access control (MAC) bridges (includes IEEE 802.1p Priority
and Dynamic Multicast Filtering, GARP, GMRP)
IEEE 802.1 Q
Tagging
IEEE 802.1 Q-1998
Virtual Bridged Local Area Networks (VLAN Tagging, GVRP)
IEEE 802.1 w.2001
Rapid Reconfiguration
IEEE 802.3-2002
Ethernet
Table 16: List of IEEE standards
Name
Operating
temperature
(chassis)
Order number
Release 02 10/10
53
A
Further Support
Technical Questions and Training Courses
In the event of technical queries, please contact your local Hirschmann
distributor or Hirschmann office.
You can find the addresses of our distributors on the Internet:
www.beldensolutions.com.
Our support line is also at your disposal:
Tel. +49 1805 14-1538
Fax +49 7127 14-1551
Answers to Frequently Asked Questions can be found on the Hirschmann
internet site (www.beldensolutions.com) at the end of the product sites in
the FAQ category.
The current training courses to technology and products can be found
under http://www.hicomcenter.com.
Hirschmann Competence Center
In the long term, excellent products alone do not guarantee a successful
customer relationship. Only comprehensive service makes a difference
worldwide. In the current global competition scenario, the Hirschmann
Competence Center is ahead of its competitors on three counts with its
complete range of innovative services:
Consulting incorporates comprehensive technical advice, from system
evaluation through network planning to project planing.
Training offers you an introduction to the basics, product briefing and
user training with certification.
Support ranges from the first installation through the standby service
to maintenance concepts.
With the Hirschmann Competence Center, you have decided against
making any compromises. Our client-customized package leaves you
free to choose the service components you want to use.
Internet:
http://www.hicomcenter.com.