ETERNUS DX80 S2 and DX90 S2
Hardware Installation
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
Backend Cabling QSFP
Power On Procedure
Power Off Procedures
Operator Panel - Function Button
Hardware Installation ETERNUS DX80 S2 and DX90 S2
Copyright Fujitsu Technology Solutions, Release August 2011
Content
1
Package Contents (1)
Controller Enclosure Kit
Installation poster
Documentation CD
Rack mount kit
Controller Enclosure
• Single Controller Module
• Dual Controller Module
Left and right Flange Cover
Push pin tool
2 x power cords
Safety Manual
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
2
Package Contents (2)
Drive Enclosure Kit
Installation poster
Rack mount kit
Drive Enclosure
2 x power cords
1 x QSFP (SAS) cable
• Single IOM configuration
2 x QSFP (SAS) cables
• Dual IOM configuration
Safety Manual
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
3
Rack Mounting (1)
For FTS (CEMEA &I) only
Rack-mount kit
Rack mount installation overview
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
4
screws (10 mm)
2U Bracket
Rack Mounting (2)
Attach the 2U Bracket to the right rear
rack pillar
The M5 centering screws should be
inserted in the 1st and 6th holes
above the base line of the
Enclosures
Insert the pins of the left hand
side slide rail in the 1st and
3rd hole
Start counting from the bottom
of the 2U Bracket
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
Base line of the
Controller Enclosure
5
M5 Cage nut
Rack Mounting (3)
Push the M5 cage nut into the
2nd hole of the front rack pillar
Above the base line of the Enclosures
At the left hand side fix the slide
rail to the front pillar with
The M5 centering screws
The M5 pan head screws
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
M5 Centering
screw (10 mm)
M5 Pan head
screw (10 mm)
Base line of the
Controller Enclosure
6
Rack Mounting (4)
For the left hand side rail
Insert the pins in the holes of the rear pillar
Fix the other side of the slide rail to the front pillar
• Repeat the same procedure as done before with the left hand side slide rail
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
Base line of the
Controller Enclosure
M5 Cage nut
Base line of the
Controller Enclosure
M5 Pan head
screw (10 mm)
M5 Centering
screw (10 mm)
7
Rack Mounting (5)
Front view of the rack installation
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
8
Rack Mounting (6)
Fit the Controller Enclosure and/or Drive Enclosure to the rack
For better stability, a rack has to be filled by starting from the
bottom
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
9
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
For FTS (CEMEA&I) only
Connect the rack PDUs
(Power Distribution Units) to
independent AC power phases
Make sure that the AC
power switches on each
Enclosure are turned off before
connecting their power cables
Connect each Power Supply
of an Enclosure to different
Power Distribution Units
PSU#0 inlet
PSU#1 inlet
PSU#0
inlet
PSU#1
inlet
Left
Rack PDU
Right
Rack PDU
Always follow the local
power cabling regulations!
10
Backend Cabling QSFP (1)
SAS Port at the CM or IOM6 (SAS Expander)
Connect SAS (OUT) ports and SAS (IN) ports by daisy-chain
Start in ascending order from the Controller Enclosure
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
Drive Enclosure# 02
Drive Enclosure #01
Controller Enclosure
11
Backend Cabling QSFP (2)
Follow the SAS port labels at the Enclosures
This will point to the correct cabling
This sign means "IN" and this sign means "OUT"
Connect the cables according the labels showing direction ( and )
SAS ports of the Controller Enclosure always have the type "OUT"
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
Connect with
the port where
is indicated
Connect with
the port where
is indicated
DE
CE
OUT
IN
Cable symbol
OUT
12
Backend Cabling QSFP (3)
QSFP connection between racks
To connect QSFP cable between two racks an expansion cable of 3 or 6
meters is used
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
13
Single / Dual Controller Update
A single CM configuration is allowed to be upgraded to a
dual CM configuration in the field
Also the Drive Enclosure need to be upgraded
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
CE
CM #0
DE
IOM6
DE
IOM6
CE
DE
IOM6
DE
IOM6
IOM6
IOM6
Single CM
Dual CM
CA
CA
CM#0
CA
CA
CM#1
CA
CA
1 CM to 2 CM upgrade parts
CA: Channel Adapter
IOM: IO module
DE: Device Enclosure
14
Power On Procedure (1)
The ETERNUS DX S2 systems can be Powered On directly
from the Controller Enclosure
Push the Power Switch
• The "Power" LED of the CE switches on
• The power on sequence takes about 2 minutes
• If everything is OK, the green Ready LED in
the CE and the green Power LED in the DE
switch on
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
Power O
Fault
O
Active O
Power
O
Ready
O
Fault
O
Maint/ID O
Cache
O
15
Power On Procedure (2)
Controller Enclosure LEDs
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
POWER LED
Constant green when the power is turned on
READY LED
Constant green when device is available
for use
FAULT LED
Constant amber when a failure is detected
in the ETERNUS DX system
Blinks in amber when a component which
requires preventive maintenance is detected
MAINT/ID LED
Constant green when the system has its
status set to Maintenance
Blinks green
Status of all components needs to be
verified with the GUI or CLI
Locate functionality enabled by the GUI
or CLI
CACHE LED
Constant green when data exists in cache memory
Blinks in green when cached data is saved to the flash memory
16
Power On Procedure (3)
Drive Enclosure LEDs
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
LINE LED
AC power is supplied to the Drive Enclosure
FAULT LED
Constant amber when a failure is detected
in the Drive Enclosure
POWER LED
The Drive Enclosure is operating normally
DE-ID (7-segment)
Shows a 2-digit Drive Enclosure ID
Is assigned automatically by the SAS
backend cabling
2.5" Drive Ecnlosure
3.5" Drive Ecnlosure
17
Power Off Procedure
Verify with the customer that all server I/O is stopped
Also confirm that the "CACHE" LED in the Operator Panel is off
Hold down the "Power Switch" of the Controller Enclosure for
approximately 5 seconds
The ETERNUS DX system will shutdown all Enclosures gracefully
In case of moving ETERNUS to a new location, you naturally
have to also disconnect the AC power cords
from the PDUs after the system is
powered off
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
Make sure the CACHE LED
of the Controller Enclosure
is off
18
Operator Panel - Function Button (1)
Remove the plastic Flange Cover to get access to
the Function Button
The Function Button is located
next to the Power Switch
Use the pin tool to operate
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
Function Button
Power Button
2.5" Controller Enclosure
3.5" Controller Enclosure
19
Operator Panel - Function Button(2)
The operation can be performed by carrying out the following
steps
To toggle the system status between "Maintenance" and "Normal"
• Keep the Function Button pushed for three seconds
• The MAINT/ID LED lights green when the system is in Maintenance mode
• The MAINT/ID LED is off when the system is in Normal mode
Switch the functionality of Master CM to the other Controller Module
• Push down the Function Button twice within three seconds
• The Master LED lights green to indicate the Master CM
Reset the LAN ports of the CM to the default values
• Push down the Function Button three times within three seconds
• The MAINT/ID LED blinks green for a few seconds
Copyright Fujitsu Technology Solutions, Release August 2011
Hardware Installation ETERNUS DX80 S2 and DX90 S2
20