GLP IMPRESSION WWC STATIC Instruction Manual
Text of the manual
from software version 1.00/30
(Instruction version 1.00)
e-mail: [email protected]
Internet: http://www.glp.de
W
W
WW
W
WC
CC &
&
& C
CCC
CCW
W
W
SSStttaaatttiiiccc
GLP German Light Products GmbH
(Instruction version 1.00) / from software version 1.00/30)
2
Preface
This manual serves for both systems the IIM
MPPRREESSSSIIO
ONN W
WW
WCC as well as the
IIM
MPPRREESSSSIIO
ONN CCCCW
W.. The two systems differ from each other only by the number of
cold- respectively warm- white LEDs.
WWC version: 30x LEDs cold white, 60x LEDs warm white
CCW version: 60x LEDs cold white, 30x LEDs warm white
Notes:
GLP German Light Products GmbH
(Instruction version 1.00) / from software version 1.00/30)
3
Table of content
1
Description of Device.............................................................................................. 4
1.1 Safety Instructions ............................................................................................ 5
2
Preparation and Installation ................................................................................... 6
2.1 Mounting ........................................................................................................... 6
2.1.1
Mounting on the Floor (Upright) ........................................................... 7
2.1.2
Mounting in hanging Position (Head first) ............................................ 7
2.1.3
Mounting in sidewise Position .............................................................. 8
2.2 Secure the Device ............................................................................................ 9
2.3 Connections ...................................................................................................... 9
2.3.1
Power Supply....................................................................................... 9
2.3.2
DMX ..................................................................................................... 9
3
The Menu Field ...................................................................................................... 10
4
DMX Channel Selection (DMX Protocol) ............................................................. 11
55
Maintaining and Cleaning the IIM
MPPRREESSSSIIO
ONN ....................................................... 14
5.1 Safety regulations ........................................................................................... 14
5.2 Circumference and Interval (rule-of-thumb) .................................................... 14
6
Technical Specifications ...................................................................................... 15
7
Index ....................................................................................................................... 16
GLP German Light Products GmbH
(Instruction version 1.00) / from software version 1.00/30)
4
1 Description of Device
1. Moving head (actively and
passively cooled)
2. Arm with various cooling
vents
3. LCD-Display/Menu (data
entry)
4. Base with various
connectors and Camlock
mounting system
1
2
3
4
5
ba se sid e 1
6
base side 2
7
8
9
10
10
FUSE T4A
5. Power On/Off
6. DMX- Output (3 pole)
7. DMX- Input (3 pole)
8. Micro-fuse 5x20mm, T4A
9. Mains supply (Powercon)
10. 2x Safety eyes
GLP German Light Products GmbH
(Instruction version 1.00) / from software version 1.00/30)
5
1.1
Safety Instructions
The IIM
MPPRREESSSSIIO
ONN is a High-Tech Product. To guarantee a
smooth operation, it is necessary to respect the following rules.
The manufacturer of this device will not take responsibility of
damages through any disregard of the information in this
manual. Warranty claims also will be cancelled in case the
system casing is opened.
1. Make sure before putting the system into operation, that the fan and the air
inlets are clean and not blocked by anything.
2. It must be assured that the system-head can rotate unhindered throughout
his complete rotating range. A safety distance of at least 0.5 m to any easily
inflammable material (e.g. decoration material) must be adhered.
3. Attention! Don’t touch the device during the operation. This can cause
injuries or damages.
4. The system doesn’t contain any maintainable parts. Don’t open it!
5. It is necessary to wait at least 15 minutes after disconnecting the AC before
changing the optical carrier. Pay attention to possibly hot parts of the
system. -- Danger of BURNING --
6. Never look directly into the beam of light or one of the LEDs. Never use
optical apertures with a distance less than 0.5 m to observe the beam of
light. LED Class 2M. You'll risk a serious injury of your eyes and in
particular of your retina.
Attention: LED Class 2M can cause injuries of your eyes even
without optical instruments in front of them or within a distance
of less than 0.5m and short exposure time.
Hence: Avoid direct radiation of your eyes!
7. To allow a secure operation, follow also the Installation guide described in
chapter 2. Operating the IIM
MPPRREESSSSIIO
ONN without suitable safety aids like
Safety cables or clamps/hooks can increase the risk of an accident.
8. Repair-, maintenance- and installation work shall be done by qualified or
GLP certified staff only. You need to pay attention to the common rules of
technology that are not explicit mentioned in this manual.
9. Use only original spare parts. Any structural modification on the system will
terminate all warranty claims.
GLP German Light Products GmbH
(Instruction version 1.00) / from software version 1.00/30)
6
2 Preparation and Installation
2.1 Mounting
The IIM
MPPRREESSSSIIO
ONN is fully operational whether it hangs or is mounted to the
wall. It can also be operated while standing on the floor. Keep a safety distance
of 0.5 m towards any easily inflammable materials (decoration etc.).
Pay attention to the regulations of: BGV C1 (former VBG 70)
and DIN VDE 0711-217.
The installation shall be done by qualified staff only.
For the various mounting positions of the IIM
MPPRREESSSSIIO
ONN (standing on the floor,
sideways or hanging) different accessories kits are available. Through this a
safe and firm installation is assured. You'll find special connectors on the
bottom side of the system which are put to use here. In addition the front side of
the system is marked with (FRONT) as this is important for a even orientation
during installation.
GLP German Light Products GmbH
(Instruction version 1.00) / from software version 1.00/30)
7
1x M10
(length max.16mm)
2x Camlock
quick release
fasteners
front side of the fixture
2.1.1 Mounting on the Floor (Upright)
To operate the IIM
MPPRREESSSSIIO
ONN in an upright position, please use the
dedicated tripod which is mounted to the bottom side of the system. It is
fixed with fasteners called Camlock quick-release connectors. Turn the
two fasteners both 90° to lock them. Do the opposit e to release them
again. On both sides you'll find eyelets to pull though a fixing strap. This
allows an additional bracing of the system during the upright operation.
2x Camloc k
2x eyelets
2.1.2 Mounting in hanging Position (Head first)
To operate the IIM
MPPRREESSSSIIO
ONN in an hanging position, please use a half-
coupler (clamp) which is mounted directly to the bottom side of the
system. It is fixed centrically with a M10x16 mm thread bolt.
GLP German Light Products GmbH
(Instruction version 1.00) / from software version 1.00/30)
8
M10x16
2.1.3 Mounting in sidewise Position
To operate the IIM
MPPRREESSSSIIO
ONN in a sidewise position, please use an
addition mounting bar. Also this is fixed by two Camlock quick-release
connectors. Two half-couplers (clamps) are now used to mount the
system to a standard truss bar. This technique is necessary to cope with
the torque which accrues in this mounting position. In addition it allows a
concentrically position between two truss belts. Never use the "Mounting
in hanging Position" technique described above to fasten the system in
the sidewise position. A safe and sound installation can not be assured
in this way. This can also damage the system base.
2x 90°
Half-coupler (clamp) 1
Half-coupler (clamp) 2
GLP German Light Products GmbH
(Instruction version 1.00) / from software version 1.00/30)
9
without mounting bar
2.2 Secure the Device
Regardless of the mounting method of the IIM
MPPRREESSSSIIO
ONN you'll have to use a
stipulated safety wire. Therefore you have to pull the safety wire through to two
provided holes on the bottom side of the system and connect it with the truss-
support. Pay attention to a safe and proper fastening. Install a safety wire that
can hold at least 10 times the weight of the fixture. Never use the carrying
handles for this purpose.
The safety wire must be attached in a way that the height of drop is
minimised. A height of drop of more that 0.2m is strictly forbidden (
BGI
810-3).
2.3 Connections
2.3.1 Power Supply
~100-240 Volt AC, 50-60 Hz, earth contact type plug - Powercon
Connected load 350 VA (W) <=> T4A (micro-fuse 5x20mm)
Please see printing on the case for the right electronic supply!
Disconnect from the mains supply for changing the fuse and use
only the above described micro-fuse type.
2.3.2 DMX
USITT DMX-512 Standard input/output in 3 pole connectors.
3 pole: Pin 1 = [Ground] / Pin 2 = [-] / Pin 3 = [+]
The DMX- Addressing starts at the DMX- Address [001].
GLP German Light Products GmbH
(Instruction version 1.00) / from software version 1.00/30)
10
3 The Menu Field
You’ll find the control board on the side part of the arm. It allows you to
make all necessary adjustments of the IIM
MPPRREESSSSIIO
ONN.. With the Mode-
key you get into the main menu. Afterwards you can navigate through
the menu with the Up/Down-keys. Push the Enter-key to get in the next
menu level or to confirm your settings. Make them and set functions
ON/OFF with the Up/Down-keys. Confirm and save it with the Enter-key
(the display shows OK). Push the Mode-key to cancel the entry and go
back to the main menu.
Mode
Down
Enter
Up
MODE - ENTER
Level1
Level 2
Level 3
Level 4
Remark
DMX Start
Address
Define the DMX start address
Special
Manual DMX
Manual control of all system functions
Special
Activate the White- or Full-Power Mode; see also
DMX table
Dimmer
Manual control for Dimmer
DOWN - UP
Shutter
Manual control for Shutter
1/3 White
Manual control for 1/3 white, 30x LEDs (either
warm- or cold white depending on the system)
2/3 White
Manual control for 2/3 white, 60x LEDs (either
warm- or cold white depending on the system)
Display
Contrast
Adjustment for the Display contrast
Default Set
Resetting all functions to original values
Set Dimmer
Frequency
Changes PMW frequency between 600Hz and
1200Hz
Adjust
Key code
xxxx
Use the code for entering the calibration menu (for
authorized persons only)
Clear
EEPROM
Erase EEPROM memory
Diagnose
Diagnose functions
Anz Ti0-Int-
Err
Internal data and function diagnosis
Dimmerwert
für DIM1
Internal data and function diagnosis
Dimmerwert
für DIM2
Internal data and function diagnosis
Dimmerwert
für DIM3
Internal data and function diagnosis
PFC
Voltage
Shows the present PFC voltage
Temperature
Arm
Indicates the arm temperature
Temperature
Head
Indicates the head temperature
DMX Hold
Defines whether the last DMX signal is stored or the
lamp is switched OFF in case of signal interruption
Position
Feedback
Automatically position feedback (correction) for
Pan/Tilt movement
Set DMX
Image
Stores the Scene currently sent to the unit
GLP German Light Products GmbH
(Instruction version 1.00) / from software version 1.00/30)
11
DMX input
Monitor
Indicates the presently received DMX signal per
DMX channel
Special
Current value for Special
Dimmer
Current value for Dimmer
Shutter
Current value for Shutter
1/3 White
Current value for 1/3 White, 30x LEDs (either warm-
or cold white depending on the system)
2/3 White
Current value for 2/3 White, 60x LEDs (either warm-
or cold white depending on the system)
Self Test
Performs an automatic self-test
Live time
Indicates the overall operation time of the system
Display
Adjust the display
Blackout
ON/OFF: Display OFF
Select DMX
Mode
Please select the desired DMX Mode
Compressed
Only 5 DMX channels are being used if this Mode is
activated
Normal
4 DMX channels are being used if this Mode is
activated
High-
Resolution
7 DMX channels are being used if this Mode is
activated. Dimmer operates at 16 bit.
Reset
RESET and new calibration for all functions
4 DMX Channel Selection (DMX Protocol)
Normal-Mode 5 DMX channels
Channel
Function
Time and Value
DMX
HEX
%
1) White 2/3 White Color, 60x LEDs (either warm-
or cold white depending on the system)
0 - 100%
0..255
00..FF
0..100
2) White 1/3 White Color, 30x LEDs (either warm-
or cold white depending on the system)
0 - 100%
0..255
00..FF
0..100
3) Shutter
Shutter closed
0..15
00..0F
0..5,5
Random Pulse effect
slow - fast
16..47
10..2F
6..18,5
Up-dimming then Shutter closing
(random patterns)
slow - fast
48..79
30..4F
19..31
Shutter open then down-dimming
(random patterns)
slow - fast
80..111
50..6F
32..43
Up-dimming then down-dimming
(random patterns)
slow - fast
112..143
70..8F
44..56
Strobe effect, stop break
5 sec. - 1 sec.
144..199 A0..C7
57..77
Strobe effect, slow - fast
1 Hz .. 10 Hz
200..239 C8..EF
78..94
Shutter open
240..255
F0..FF
95..100
4) Dimmer
Dimmer
0 - 100%
0..255
0..FF
0..100
5) Special
Fan min. as long as temp. < 60°C
224..249
E0..E5 88..89,5
RESET (Normal Mode)
250..255 FA..FF
98..100
GLP German Light Products GmbH
(Instruction version 1.00) / from software version 1.00/30)
12
Compress-Mode 4 DMX channels
Channel
Function
Time and Value
DMX
HEX
%
1) White 2/3 White Color, 60x LEDs (either warm-
or cold white depending on the system)
0 - 100%
0..255
00..FF
0..100
2) White 1/3 White Color, 30x LEDs (either warm-
or cold white depending on the system)
0 - 100%
0..255
00..FF
0..100
3) Shutter
Shutter closed
0..15
00..0F
0..5,5
Random Pulse effect
slow - fast
16..47
10..2F
6..18,5
Up-dimming then Shutter closing
(random patterns)
slow - fast
48..79
30..4F
19..31,5
Shutter open then down-dimming
(random patterns)
slow - fast
80..111
50..6F
32..43
Up-dimming then down-dimming
(random patterns)
slow - fast
112..143
70..8F
44..56
Strobe effect, stop break
5 sec. - 1 sec.
144..199 A0..C7
57..77
Strobe effect, slow - fast
1 Hz .. 10 Hz
200..239 C8..EF
78..94
Shutter open
240..249
F0..F9 95..97,5
RESET
Min. 3 Sec.
250
FA
98
4) Dimmer
Dimmer
0 - 100%
0..255
0..FF
0..100
High Resolution (Extended)- Mode 11 DMX Channels
Channel
Function
Time and Value
DMX
HEX
%
1) White 2/3
coarse
White Color, 60x LEDs (either warm-
or cold white depending on the system)
0 - 100%
0..255
00..FF
0..100
2) White 2/3
fine
White - fine/low
0..255
00..FF
0..100
3) White 1/3
coarse
White Color, 30x LEDs (either warm-
or cold white depending on the system)
0 - 100%
0..255
00..FF
0..100
4) White 1/3
fine
White - fine/low
0..255
00..FF
0..100
5) Shutter
Shutter closed
0..15
00..0F
0..5,5
Random Pulse effect
slow - fast
16..47
10..2F
6..18,5
Up-dimming then Shutter closing
(random patterns)
slow - fast
48..79
30..4F
19..31,5
Shutter open then down-dimming
(random patterns)
slow - fast
80..111
50..6F
32..43
Up-dimming then down-dimming
(random patterns)
slow - fast
112..143
70..8F
44..56
Strobe effect, stop break
5 sec. - 1 sec.
144..199 A0..C7
57..77
Strobe effect, slow - fast
1 Hz .. 10 Hz
200..239 C8..EF
78..94
RESET
Min. 3 Sec.
250
FA
98
6) Dimmer-
coarse
Dimmer - coarse/high
0 - 100%
0..255
0..FF
0..100
7) Dimmer-
fine
Dimmer - fine/low
0..255
0..FF
0..100
GLP German Light Products GmbH
(Instruction version 1.00) / from software version 1.00/30)
13
Locking and unlocking the Control Panel
Please lock and unlock the control panel by pressing the menu keys MODE & ENTER & UP
at the same time.
Additional features during switching-ON the system
a) 1200Hz Mode (Hold down the UP- button during power ON)
After switching ON the system the LEDs will be operated with a Pulse Width Modulation
(PWM) of 1200Hz.
In addition all standard setting will be loaded (DMX start address [001] and Normal Mode.
b) 600Hz Mode (Hold down the DOWN- button during power ON)
After switching ON the system the LEDs will be operated with a Pulse Width Modulation
(PWM) of 600Hz.
In addition all standard setting will be loaded (DMX start address [001] and Normal Mode.
c) Standard Mode (Hold down the ENTER- button during power ON)
After switching ON the system the DMX start address will be set to [001]. All other setting
remain unchanged.
Additional Display Indication
As a default you'll find the following additional information in the first row of the LCD display:
XX/X/XX
06 = 600Hz / 12 = 1200Hz
N = Normal Mode / C = Compressed Mode / H = High Res. Mode
N = Tilt normal / I = Tilt inverted
N = Pan normal / I = Pan inverted
GLP German Light Products GmbH
(Instruction version 1.00) / from software version 1.00/30)
14
55 Maintaining and Cleaning the IIM
MPPRREESSSSIIO
ONN
The IIM
MPPRREESSSSIIO
ONN is a system of very low maintenance. It is only necessary to clean
the air in- and outlets as well as the optical LED lenses from time to time. For a safe
operation it is absolutely essential that the fixture is kept clean and that dust, dirt and
smoke-fluid residues must not built up on or within the fixture. Otherwise the fixture's
light-output will be significantly reduced or damages can occur. Regular cleaning will
not only ensure the maximum light-output, but will also allow the fixture to operate
reliably throughout its life.
A soft lint-free cloth moistened with any good glass cleaning fluid is recom-
mended, under no circumstances should alcohol or solvents be used!
5.1 Safety regulations
• Pull out the main plug!
• Wait min. 15 minutes after the last operation to cool down the fixture.
5.2 Circumference and Interval (rule-of-thumb)
The contamination of the fixture depends on the environment details. Hence no
general guidelines can be given. The intervals given below are only suggestions
from our practice experience.
Position
Interval
In this way
LED reflector and optical system
weekly
soft brush /lint-free cloth
Fan and air channel
monthly
vacuum cleaner, airbrush, etc.
Attention:
• Never let optical parts come into contact with oil or fat.
• Before running the fixture wait until all parts are dried up.
• Never tough lenses with bare fingers.
GLP German Light Products GmbH
(Instruction version 1.00) / from software version 1.00/30)
15
6 Technical Specifications
Power supply
Power consumption
350 VA (Watt)
Power Input
~100-240 V AC, 50-60 Hz (wide range input)
Fuse protection
Micro-fuse 5x20 mm, T4A
Operational Parameters
Max. Ambient
Temperature
45°C (integrated overheating switch)
Mounting Position
Any (see chapter mounting)
Lighting System - Additive Color mixing (8/16 Bit)
LED Type
90x Luxeon K2 High-power- LEDs
Lifetime
50.000 h
CCW version: 60x LEDs cold white, 30x LEDs warm white
WWC version: 30x LEDs cold white, 60x LEDs warm white
Optical System
High efficient Collimator cluster
Exchangeable optical carrier with 10° light distrib ution angle (25° optional)
Scattering light aperture
Shutter / Dimmer (8 Bit)
Strobe- Effect with variable speed between 1 - 10 flashes per second, Random-Strobe, Pulse-
Effects
Continuous Dimmer 0 - 100%
DMX Control
Standard USITT DMX-512, 3 pole XLR; [+] = Pin 3 [-] = Pin 2 [Ground] = Pin 1.
Die DMX- Addressing starts at the DMX channel [001].
Pan / Tilt (8/16 Bit)
Pan- movement
660° in min. 3,2 seconds (Position Feedback)
Tilt- movement
300° in min. 1,5 seconds (Position Feedback)
Weights and Measures
Width of the base
340 mm
Length of the base
145 mm
height (head vertical)
370 mm
Weight (net)
7,5 kg
GLP German Light Products GmbH
(Instruction version 1.00) / from software version 1.00/30)
16
7 Index
1
1200Hz Mode ................................................ 13
6
600Hz Mode .................................................. 13
B
BGI 810-3 ........................................................ 9
BGV C1............................................................ 6
C
Camlock ........................................................... 7
CCW version .................................................. 2
Circumference ............................................... 14
Cleaning......................................................... 14
Cold white LEDs .............................................. 2
Compress-Mode .......................................... 12
D
Danger of BURNING ...................................... 5
Description of Device ....................................... 4
DIN VDE 0711-217 .......................................... 6
DMX ................................................................. 9
DMX Protocol ................................................ 11
E
e-mail ............................................................... 1
Enter-key ....................................................... 10
Eyelets ............................................................. 7
H
Half-couplers (clamps) ..................................... 8
I
Instruction Version ........................................... 1
Internet............................................................. 1
L
LED Class 2M ................................................. 5
Locking the Control Panel .......................... 13
Luxeon K2 ..................................................... 15
M
Maintenance ................................................. 14
Menu Field .................................................... 10
Micro-fuse ....................................................... 9
Mode-key ...................................................... 10
Mounting ........................................................ 6
Mounting in hanging Position .......................... 7
Mounting in sidewise Position ......................... 8
Mounting on the Floor ..................................... 7
N
Normal-Mode ............................................... 11
O
Optical parts ................................................ 14
P
Pan- Movement ............................................. 15
Power Supply ................................................ 9
Powercon ........................................................ 4
S
Safety distance ............................................... 6
Safety Instructions .......................................... 5
Secure the Device ......................................... 9
Software Version ............................................. 1
T
Technical Specifications ............................ 15
Tilt- Movement .............................................. 15
U
Up/Down-keys .............................................. 10
V
VBG 70 ........................................................... 6
W
Warm white LEDs ........................................... 2
Warranty claims .............................................. 5
Weights and Measures ................................. 15
WWC version ................................................. 2
GLP German Light Products GmbH
(Instruction version 1.00) / from software version 1.00/30)
17