Datalogic DS8100A Reference Manual
Text of the manual
Datalogic Automation Srl
Via Lavino, 265
40050 - Monte S. Pietro
Bologna - Italy
DS8100A Reference Manual
Ed.: 11/2013
© 2005 – 2013 Datalogic Automation S.r.l. ALL RIGHTS RESERVED. Protected to the fullest
extent under U.S. and international laws. Copying, or altering of this document is prohibited without
express written consent from Datalogic Automation S.r.l.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries,
including the U.S.A. and the E.U.
Genius, PackTrack, ACR, ASTRA, CD SQUARE and ID-NET are trademarks of Datalogic Automation
S.r.l. All other brand and product names mentioned herein are for identification purposes only and may
be trademarks or registered trademarks of their respective owners.
Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for
incidental or consequential damages resulting from the use of this material.
19/11/13
REFERENCES .......................................................................................................... vi
Reference Documentation ......................................................................................... vi
Support Through The Website ................................................................................... vi
Patents ...................................................................................................................... vi
COMPLIANCE .......................................................................................................... vii
Electrical Safety ........................................................................................................ vii
Laser Safety .............................................................................................................. vii
Power Supply ............................................................................................................viii
CE Compliance .........................................................................................................viii
FCC Compliance ........................................................................................................ ix
GENERAL VIEW ........................................................................................................ x
GUIDE TO INSTALLATION ...................................................................................... xii
Point-to-Point Installation .......................................................................................... xii
Master/Slave Lonworks Installation ...........................................................................xiii
1
INTRODUCTION ........................................................................................................ 1
1.1
Product Description ..................................................................................................... 1
1.2
Applications ................................................................................................................ 1
1.3
Model Description ....................................................................................................... 3
1.4
Oscillating Mirror Models ............................................................................................. 3
1.5
Indicators .................................................................................................................... 4
1.6
Keypad and Display .................................................................................................... 5
1.6.1 Internal Net ................................................................................................................. 5
1.6.2 Test Mode ................................................................................................................... 5
1.6.3 PackTrack (Auto) ........................................................................................................ 6
1.7
Auto PackTrack™ Calibration for Reading Station Using Scanner Menu .................... 7
1.7.1 Auto PackTrack Conditions and Limits ........................................................................ 7
1.7.2 Auto PackTrack Parameter Descriptions ..................................................................... 8
1.7.3 Auto PackTrack Setup ................................................................................................ 9
1.8
Accessories .............................................................................................................. 12
2
INSTALLATION ........................................................................................................ 14
2.1
Package Contents ..................................................................................................... 14
2.2
Mechanical Mounting ................................................................................................ 15
2.2.1 Mounting the Scanner ............................................................................................... 15
2.2.2 Mounting the Scanner with Accessories .................................................................... 16
2.3
Positioning the Scanner ............................................................................................ 18
3
CBX ELECTRICAL CONNECTIONS ........................................................................ 19
3.1
Power Supply ............................................................................................................ 21
3.2
Main Serial Interface ................................................................................................. 21
3.2.1 RS232 Interface ........................................................................................................ 22
3.2.2 RS485 Full-Duplex Interface ..................................................................................... 23
3.2.3 RS485 Half-Duplex Interface ..................................................................................... 24
3.3
Auxiliary RS232 Interface .......................................................................................... 26
3.4
Inputs ........................................................................................................................ 27
3.4.1 Code Verifier ............................................................................................................. 31
3.5
Outputs ..................................................................................................................... 31
User Interface - Host ................................................................................................. 34
4
CUSTOM CABLE ELECTRICAL CONNECTIONS ................................................... 35
4.1
Power Supply ............................................................................................................ 37
4.2
Main Serial Interface ................................................................................................. 37
4.2.1 RS232 Interface ........................................................................................................ 38
4.2.2 RS485 Full-Duplex Interface ..................................................................................... 39
4.2.3 RS485 Half-Duplex Interface ..................................................................................... 40
4.3
Auxiliary Interface ..................................................................................................... 42
4.4
Inputs ........................................................................................................................ 42
4.4.1 Code Verifier ............................................................................................................. 45
4.5
Outputs ..................................................................................................................... 45
4.6
User Interface ........................................................................................................... 47
5
LONWORKS CONNECTIONS ................................................................................. 48
5.1
Network Termination ................................................................................................. 49
5.2
Lonworks Interface .................................................................................................... 50
6
FIELDBUS CONNECTIONS ..................................................................................... 52
6.1
Ethernet Interface ..................................................................................................... 52
6.2
Ethernet Interface (older models) .............................................................................. 53
7
TYPICAL LAYOUTS................................................................................................. 55
7.1
Local Lonworks Network ........................................................................................... 55
7.1.1 Small Synchronized Network .................................................................................... 56
7.1.2 Large Synchronized Network .................................................................................... 58
7.1.3 Redundant System ................................................................................................... 60
7.1.4 Multidata Network ..................................................................................................... 62
7.1.5 Fieldbus Networks .................................................................................................... 63
8
SOFTWARE CONFIGURATION............................................................................... 65
8.1
Genius™ Installation ................................................................................................. 65
8.2
Guide to Rapid Configuration .................................................................................... 65
8.2.1 Wizard for Quick Reader Setup ................................................................................. 65
8.2.2 Genius™ Network Setup Through Master ................................................................. 68
8.2.3 Alternative Slave Address Assignment ...................................................................... 73
8.3
Advanced Genius™ Configuration ............................................................................ 73
8.3.1 Genius™ Shortcuts for Network Configuration .......................................................... 74
8.4
Parameter Default Values ......................................................................................... 76
9
READING FEATURES ............................................................................................. 81
9.1
Advanced Code Reconstruction (ACR™ 4) ............................................................... 81
9.1.1 Tilt Angle for Advanced Code Reconstruction ........................................................... 81
9.2
PackTrack™ ............................................................................................................. 82
9.2.1 Auto PackTrack™ Calibration for Reading Station Using DLAPC ............................. 84
9.2.2 Manual PackTrack™ Calibration for DS8100A Scanner Using SPY .......................... 91
9.2.3 PackTrack™ Calibration for DS8100A Oscillating Mirror Models .............................. 94
9.3
Performance ............................................................................................................. 95
9.3.1 Reading Conditions ................................................................................................... 95
9.4
Reading Diagrams .................................................................................................... 97
10
MAINTENANCE ..................................................................................................... 107
10.1
Cleaning.................................................................................................................. 107
10.2
External Memory Backup & Restore ....................................................................... 107
10.3
Automatic Scanner Replacement (ASR) ................................................................. 107
10.3.1 ASR Network Configuration .................................................................................... 108
10.3.2 Scanner Replacement Procedure ........................................................................... 108
11
TROUBLESHOOTING ............................................................................................ 109
12
TECHNICAL FEATURES ....................................................................................... 112
A
ALTERNATIVE LAYOUTS ..................................................................................... 114
Point-to-Point .......................................................................................................... 114
ID-NET™ Gateway ................................................................................................. 116
Pass Through ......................................................................................................... 117
RS232 Master/Slave ............................................................................................... 118
Multiplexer .............................................................................................................. 120
GLOSSARY ............................................................................................................ 121
INDEX ..................................................................................................................... 124
The documentation related to the DS8100A management is listed below:
PWR series power supply unit Installation Manuals
SC6000 Controller Reference Manual
PWO power supply unit Installation Manual
GFC-80 90° Deflecting Mirror
GFC-800A Adjustable Mirror for Close Distance Reading
CBX100/500 Installation Manuals
Document about the Ethernet connectivity
ID-NET™ Fixed Baudrate Application Note
Help On-Line in PDF format
SUPPORT THROUGH THE WEBSITE
Datalogic provides several services as well as technical support through its website. Log on
to www.datalogic.com and click on the Industrial Automation links for further information:
Products - Industrial Automation - Identification
Select your product from the links on the Identification page. The product page
describes specific Info, Features, Applications, Models, Accessories, and Downloads
including documentation, software drivers, and the Genius™ utility program, which
allows device configuration using a PC through Serial and Ethernet interfaces.
Support & Services - Industrial Automation
Several links from the Industrial Automation list take you to additional services such as:
Service Program which contains Maintenance Agreements and Warranty Extensions;
Repair Centers; On-Line RMA Return Material Authorizations; Technical Support through
email or phone, Partner Program; Downloads for additional downloads.
PATENTS
This product is covered by one or more of the following patents:
U.S.
patents:
Re. 36,251;
5,992,740;
6,347,740 B1;
6,177,979 B1;
6,394,352 B1;
6,443,360 B1; 6,527,184 B1; 6,629,639 B2; 6,742,710 B2; 7,161,685 B1.
European patents: 652,530 B1; 789,315 B1; 851,376 B1; 926,615 B1; 959,426 B9;
1,217,571 B1; 1,363,228 B1; 1,607,901 B1.
Japanese patents: 3,793,585 B2; 4,033,958 B2; 4,376,353 B2.
This product conforms to the applicable requirements contained in the European Standard for
electrical safety EN-60950 at the date of manufacture.
WARNING
This symbol refers to operations that must be performed by qualified
personnel only. Example: opening the device.
WARNING
This symbol refers to operations where there is danger of electrical
shock. Before opening the device make sure the power cable is
disconnected to avoid electric shock.
LASER SAFETY
The following information is provided to comply with the rules imposed by international
authorities and refers to the correct use of the DS8100A scanner.
Standard Regulations
This scanner utilizes up to 4 low-power laser diodes. Although staring directly at the laser
beam momentarily causes no known biological damage, avoid staring at the beam as one
would with any very strong light source, such as the sun.
Avoid that the laser beam hits the eye of an observer, even through reflective surfaces such
as mirrors, etc.
This product conforms to the applicable requirements of both EN60825-1 and
CDRH 21 CFR1040 at the date of manufacture. The reader is classified as a Class 2 laser
product according to EN60825-1 regulations and as a Class II laser product according to
CDRH regulations.
There is a safety device which allows the laser to be switched on only if the motor is rotating
above the threshold for its correct scanning speed.
WARNING
Use of controls or adjustments or performance of procedures other than those
specified herein may result in exposure to hazardous visible laser light.
The laser light is visible to the human eye and is emitted from the window on the side of the
scanner (Figure A).
Warning labels indicating exposure to laser light and the device classification are applied
onto the body of the scanner (Figure A):
AVOID EXPOSURE
LASER LIGHT IS EMITTED
FROM THIS APERTURE
CAUTION-CLASS 3B
LASER LIGHT
WHEN OPEN
AVOID
EXPOSURE TO BEAM
Model No.
Amp.
Serial No.
DATALOGIC AUTOMATION S.r.l. - Via Lavino 265
40050 Monte San Pietro - Bologna - Italy
Manufactured
Volt
This product conforms to the applicable requirements
of 21CFR1040 at the date of manufacture.
LASER LIGHT
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
MAXIMUM OUTPUT RADIATION 1 mW
EMITTED WAVELENGTH 630~680 nm
TO EN 60825-1:2001
Warning and Device Class Labels
Disconnect the power supply when opening the device during maintenance or installation to
avoid exposure to hazardous laser light.
The laser diodes used in this device are classified as Class 3B laser products according to EN
60825-1 regulations and as Class IIIb laser products according to CDRH regulations. Any
violation of the optic parts in particular can cause radiation up to the maximum level of the
laser diode (30 mW at 630~680 nm).
POWER SUPPLY
This product is intended to be installed by Qualified Personnel only.
- This scanner is intended to be supplied by either a UL Listed power supply marked 'Class
2' or 'LPS', output rated 20 – 30 V dc , minimum 1.3 A or by a UL Listed computer with
LPS outputs.
- This scanner must be supplied by a Class II Power Supply Unit conforming to the
EN 60950 safety regulation.
CE COMPLIANCE
Warning:
This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Modifications or changes to this equipment without the expressed written approval of
Datalogic could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference which may cause undesired
operation.
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
Figure A – DS8100A
Laser Beam Output Window
Laser Safety Label
Product Label
Warning and Device Class Label
1
2
3
4
Connector Panel
Display
Service Access Cap
5
6
7
Mounting Holes
8
DS8100A-XXX5
Figure B – DS8100A Oscillating Mirror Models
Laser Beam Output Window
1
Laser Safety Label
2
1
2
1
2
8
5
3
4
6
7
Figure C – Display and Keypad Panel
Programming Keypad
Power On LED (Green)
Phase On LED (Yellow)
Encoder LED (Yellow)
1
2
3
4
TX Data LED (Green)
Network LED (Red)
LCD Display
5
6
7
Figure D – Connector Panel for Standard Models
Lonworks 17-pin male connector
Lonworks 17-pin female connector
1
2
Serial interface and I/O 26-pin connector
3
Figure E – Connector Panel for Ethernet Models
Figure F – Connector Panel for (older) Ethernet Models
Lonworks 17-pin male connector
Lonworks 17-pin female connector
Harting RJ industrial connector
1
2
4
Serial interface and I/O 26-pin connector
3
1
2
3
1
2
4
3
7
1
2
3
4
5
6
1
2
4
3
Lonworks 17-pin male connector
Lonworks 17-pin female connector
Ethernet M12 4-pin female connector
1
2
4
Serial interface and I/O 26-pin connector
3
GUIDE TO INSTALLATION
POINT-TO-POINT INSTALLATION
The following can be used as a checklist to verify all the necessary steps to complete
installation of the DS8100A scanner.
1) Read all information in the section “Safety Regulations” at the beginning of this manual.
2) Correctly mount the scanner according to the information in par. 2.2 and position it at the
correct reading distance as shown in par. 2.3 and par. 9.4.
3) Make electrical connections to your DS8100A scanner by:
a) Connecting the DS8100A scanner to the CBX connection box by means of one of the
CAB-F0x cables provided as accessory (see par. 1.8).
b) Providing correct and complete system cabling through the CBX connection box
according to the signals necessary for the layout of your application (trigger, inputs,
outputs).
Cabling: Power, Interface, Inputs, Outputs, etc. For further details, see chapter 3
(chapter 4 for custom cabling).
Alternative Layouts: Point-to-Point, Pass Through, RS232 Master/Slave,
Mutliplexer. See appendix A for layout references.
4) Configure the DS8100A scanner by installing and running the Genius™ configuration
program from the CD-ROM provided. See chapter 8 and the Help On-Line for details.
The main steps are:
Select the codes to be read
Set-up the communication parameters
When PackTrack™ is required, perform PackTrack™ calibration
Define data formatting parameters
NOTE
Fine tuning of the scanner position for barcode reading can be
accomplished by performing a test through the SPY configuration tool in
Genius™.
5) Exit the configuration program and run your application.
The installation is now complete.
MASTER/SLAVE LONWORKS INSTALLATION
The following can be used as a checklist to verify all the steps necessary to complete
installation of the DS8100A scanner in a Master/Slave Lonworks network.
1) Read all information in the section “Safety Regulations” at the beginning of this manual.
2) Correctly mount the scanner according to the information in par. 2.2 and position it at the
correct reading distance as shown in par. 2.3 and par. 9.4.
3) Make electrical connections to your DS8100A scanner by:
a) Connecting the DS8100A Master scanner to the CBX100 by means of one of the
CAB-F0x cables provided as accessory (see par. 1.8).
b) Correctly terminating the DS8100A Master reader according to the information given
in par. 5.1 and par. 7.1.
c) Completing the system wiring adding as many slave scanners as required by your
system layout (refer to par. 7.1).
d) Correctly providing bus return to the last DS8100A Slave reader of the network
according to the information given in par. 5.1 and par. 7.1.
4) Install and run the Genius™ configuration program from the CD-ROM provided.
Configure the Local Lonworks Network using one of the procedures given below:
Configure the entire network through the Master as described in par. 8.2.2;
Configure the Master as described in par. 8.2.2 and locally define each slave scanner
address as described in par. 8.2.3.
Define each scanner, master and slaves (with their addresses), by using the scanner
keypad according to the information given in par. 1.6.1.
5) Configure the Master scanner through the Genius™ program. See chapter 8 and the
Help On-Line for details. The main steps are:
Select the codes to be read
Set-up the communication parameters
When PackTrack™ is required, perform PackTrack™ calibration, see par. 9.2.1.
Define data formatting parameters
6) Configure each Slave scanner through the Master scanner using Genius™. See chapter
8 and the Help On-Line for details. The main steps are:
Select the codes to be read
When PackTrack™ is required, perform PackTrack™ calibration, see par. 9.2.1.
NOTE
Fine tuning of the scanner position for barcode reading can be
accomplished by performing a test through the SPY configuration tool in
Genius™.
7) Send the configuration to the Master.
8) Perform the External Memory Backup procedure for system backup purposes (see par.
10.2). For backward compatibility you can perform the ASR Network Configuration
procedure for system backup purposes (see par. 10.3.1).
9) Exit the configuration program and run your application.
The installation is now complete.
1.1 PRODUCT DESCRIPTION
The DS8100A scanner is a barcode reader complete with decoder designed to provide an
innovative and high performance solution in omnidirectional reading applications by
combining the following advanced technologies with Datalogic solid experience in the
material handling sector.
Some of the main features of DS8100A are listed below:
scanning speed 1000 scans/sec.
reads all popular codes.
supply voltage from 20 to 30 Vdc.
test mode to verify the reading features and exact positioning of the scanner without the
need for external tools.
programmable in several different operating modes to suit the most various barcode
reading system requirements.
light source: solid state laser diodes; the light emitted has a wave length between
630~680 nm. For laser safety precautions refer to the “Compliance” section at the
beginning of this manual.
1.2 APPLICATIONS
The DS8100A barcode reader is specifically designed for industrial applications and for all
cases requiring high reading performance such as:
code reconstruction
reading of codes covered by plastic film
reading of codes with a wide depth of field
reading of high resolution codes positioned at long distances from the reader
code reading on fast moving objects.
DS8100A is designed for both single-reader layouts and multi-reader layouts. For typical
layouts see chapter 7 and appendix A.
DS8100A REFERENCE MANUAL
2
1
Feature
Benefit
ACR™
Advanced
Code
Reconstruction
technology
allows the reading of low aspect ratio labels
placed anywhere on a parcel and enhances the
readability of poorly printed or damaged codes.
CD SQUARE™
CD SQUARE™ provides useful information on
label position and object shape elaborated during
the barcode reading phase. This innovative
technology identifies the area in which the code is
located and measures the code distance from the
scanner.
PACKTRACK™
PackTrack™ is a Datalogic patented parcel
tracking system which improves the reading
features in omnidirectional stations. In particular,
PackTrack™ manages 6-sided reading systems
when it is impossible to detect the real position of
the code on the parcel, thus overcoming the need
for external accessories essential in traditional
tracking systems.
ASTRA™
Automatically SwiTched Reading Area™ is the
new Datalogic technology based on a multi-laser
architecture and a fixed mounted optic system
which concentrates the multiple laser emissions in
a single laser beam. As each laser emitter is
focused on a specific range of the reading area, a
sophisticated electronic controller selects the best
focused laser emitter with respect to the code to
read. This allows the reading of medium-high
density codes in a large reading area on very fast
conveyors.
Flexibility
The high frequency laser diode modulation
system guarantees complete immunity to ambient
light and allows installation of the DS8100A in any
working area.
Reading parcels on conveyors
As a result of the ASTRA™ multiple laser
technology, DS8100A gives a great real time DOF
even on high speed conveyors. Furthermore,
DS8100A
implements
the
Packtrack™
functionality which leads to an increase of the
plant production as a result of the augmented
system throughput.
Master working as a
Multiplexer on high speed
Lonworks bus
Great competitiveness of the offer, since the cost
of an external multiplexer is saved;
High data transfer on an industrial, reliable bus
running at 1.25 Mbit/sec.
Genius™ Configurator SW
Reduced learning time, with an easy wizard
approach;
Multilanguage platform;
All the configuration parameters stored in the
scanner;
Not dependent on the Physical interface.
A software parameter group which allows
management of the energy saving feature. In
particular, it allows turning on/off the motor and
laser of all network scanners according to the
selected digital input, encoder, or communication
channel.
The time required to restart the system is less
than 1 minute independently from the number of
scanners connected.
It is suggested to use this parameter for example
when the conveyor is stopped for a lengthy
period.
1.3 MODEL DESCRIPTION
The DS8100A scanner is available in versions that differ depending on the interface
connection, the optical resolution and on the optic version:
DS8100A - X X X X
Optic Version:
0 = Linear
Optical Resolution:
0 = Low resolution
1 = Medium resolution
Communication Type:
0 = Standard version
1 = Ethernet version
2 = High resolution
3 = Very High resolution
5 = Oscillating mirror
Laser Number:
2 = Double laser
3 = Triple laser
1.4 OSCILLATING MIRROR MODELS
Oscillating mirror models are used when coverage of a large reading area is required, mainly
in picket fence applications.
The oscillating mirror is placed in front of the reading aperture of the DS8100A scanner to
deflect the laser beam. As the mirror moves, this sweeping function of the laser beam allows
the coverage of a larger area to locate the barcodes. The code can also be reconstructed as
the beam sweeps over it.
DS8100A REFERENCE MANUAL
4
1
The aperture angle is symmetrical and the scan line perpendicular to the scanner is at 0° as
shown in the figure below.
0°
+25°
-25°
Figure 1- Oscillating Mirror Reference Angle
By configuring the oscillating speed up to the maximum value of 19 Hz, raster emulation can
be performed for reading fast moving objects.
Hz
Max. Aperture
0-5
50°
6-10
30°
11-15
20°
16-19
10°
NOTE
By limiting the raster width to the minimum necessary, the number of scans
on the reading surface is increased.
The oscillating mirror is completely controlled by software commands and therefore avoids
complex mechanical calibrations. For details of the software configuration parameters see
the Genius™ Help On Line.
1.5 INDICATORS
The DS8100A has five LEDs on the rear panel. The indicators have the following functions:
POWER ON
(green)
Indicates the scanner is turned on.
PHASE ON
(yellow) Indicates the external presence sensor is active.
ENCODER
(yellow) Indicates the external encoder signal is active.
TX DATA
(green)
Indicates data transmission both on the main and on the auxiliary
interface.
NETWORK
(red)
Indicates the Lonworks network is functioning correctly. This LED is
normally ON.
1.6 KEYPAD AND DISPLAY
The DS8100A keypad allows entering a menu for selection of one of the following functions:
Welcome:
shows the current software release and operating mode;
Autolearn:
starts the procedure making it possible to obtain an automatic, accurate
and fast configuration of DS8100A without the necessity of directly
checking/modifying the relevant parameters;
Internal Net:
defines scanner function within the network (see below);
Ethernet Mode: allows setting the scanner IP address to be used within the network;
LCD Contrast: sets the LCD contrast ;
Bus:
not used for DS8100A scanners;
Test Mode:
allows verifying the scanner reading position and features (see below).
PackTrack:
allows setting the Auto PackTrack Calibration procedure (see below).
The same settings may be performed by using the Genius™ program (see chapter 8 for
details).
1.6.1 Internal Net
This submenu can be used as an alternative to configuration through Genius™, to assign the
DS8100A scanner within a master/slave network.
It allows defining the scanner function (slave/master) within the network and, if configured as
Slave, its address.
To enter the Internal Net submenu and configure the scanner follow the given procedure:
1) Press and hold both the ▲ (up arrow) and ▼ (down arrow) keys for about 2 seconds to
enter the Main menu;
2) Use the ▲ (up arrow) or ▼ (down arrow) key to select the “Internal Net” item, then press
the ENT (enter) key to confirm;
3) Use the ▲ (up arrow) or ▼ (down arrow) key to select the “LonWAddrSel”” item, then
press the ENT (enter) key to confirm;
4) Use the ▲ (up arrow) or ▼ (down arrow) key to select your scanner function among
“Master”, “Slave n”, “Slave jolly”, “Disabled”; then, press the ENT (enter) key to confirm;
5) Use the ▲ (up arrow) or ▼ (down arrow) key to select the “Exit” item, then press the ENT
(enter) key to confirm. Repeat this step again to exit the Main Menu and return to the
scanner current operating mode.
1.6.2 Test Mode
Test Mode is particularly advised during the installation phase, since it causes the reader to
be continuously activated allowing verification of its reading features and its reading position
with respect to the barcode.
DS8100A REFERENCE MANUAL
6
1
To enter the Test Mode submenu and configure the scanner follow the given procedure:
1) Press and hold both the ▲ (up arrow) and ▼ (down arrow) keys for about 2 seconds to
enter the Main menu.
2) Use the ▲ (up arrow) or ▼ (down arrow) key to select the “Test Mode” item, then press
the ENT (enter) key to confirm. The reader enters Test Mode.
3) Press the ▲ (up arrow) key to exit the Test Mode.
4) Use the ▲ (up arrow) and ▼ (down arrow) key to select the “Exit” item, then press the
ENT (enter) key to confirm. The scanner exits the Main Menu and returns to its current
operating mode.
1.6.3 PackTrack (Auto)
This submenu can be used to execute the Automatic PackTrack Calibration procedure for
the Reading Station when the Master scanner is in PackTrack or Continuous Operating
Modes. Performing this procedure through the Keypad/Display Menu is an alternative to
Automatic PackTrack Calibration through the DLAPC tool in Genius™, see Help On-Line.
NOTE
This scanner must first be configured as Master of the master/slave network
(see par. 1.6.1, "Internal Net" procedure).
To enter the PackTrack submenu and configure the scanner follow the given procedure:
1) Read Par 1.7.1 regarding Auto PackTrack Conditions and Limits.
2) Press and hold both the ▲ (up arrow) and ▼ (down arrow) keys for about 2 seconds to
enter the Main menu;
3) Use the ▲ (up arrow) or ▼ (down arrow) key to select the “PackTrack” item, then press
the ENT (enter) key to confirm;
4) Use the ▲ (up arrow) or ▼ (down arrow) key and the ENT (enter) key to select the items
in the following table and set them according to your application. See par. 1.7.2 for
details;
5) After all items are set, use the ▲ (up arrow) or ▼ (down arrow) key to select “Start”; then,
press the ENT (enter) key to confirm. Follow the Procedure described in par. 1.7.3.
1.7 AUTO PACKTRACK™ CALIBRATION FOR READING STATION
USING SCANNER MENU
1.7.1 Auto PackTrack Conditions and Limits
The Conditions and Limits for Auto PackTrack Calibration are summarized here for
convenience and are also integrated into the following procedure descriptions:
The following scanners are supported by Auto PackTrack Calibration: DS6400 (*see note
below), DX6400 (*see note below), DS8100A, DX8200A.
Before performing the Auto PackTrack Calibration procedure, if a system reset or power
reset is performed, wait for all the scanners to be available (up to 60 sec.) before
proceeding.
Operating Mode of the Master must be either PackTrack or Continuous.
Code 128 codes must be enabled on the Master with Label Length set to variable.
If the system Presence Sensor and Encoder are used, the correct Encoder Step value
must be set on the Master and the Presence Sensor must be connected to the
CBX100/500 Input 1.
If instead the PPA-8000 Photocell Array is used, it must be connected to the CBX100/500
I1 and I2 inputs, the following parameters must be disabled on the Master: Physical
Encoder for PackTrack or Use Encoder for Continuous, and the Encoder, if present,
must be physically disconnected.
DX scanners which are calibrated automatically cannot be automatically replaced by DX
scanners with a previous sw version (earlier than 6.80). You must either update the old
scanner software prior to substitution, or complete the calibration manually, after
installation, by setting the PSOffset and Direction parameters.
NOTE
The autofocus feature of DS6400 and DX6400 scanners makes Auto
PackTrack Calibration difficult, therefore to assure that the procedure can
correctly calibrate these scanners, it is necessary to set a fixed focus value
which allows the scanner to read all the label positions useful for its
calibration.
DS8100A REFERENCE MANUAL
8
1
1.7.2 Auto PackTrack Parameter Descriptions
Menu
Branch
Default
Note
PackTrack
Automatic Packtrack Calibration procedure for the
Reading Station
Version
2
Select the version number of the PCT-8000 pack
Cal Type
XYZ
XYZ calibration is forced.
X Cal
Absolute Absolute X position is forced.
X Offset
-
Set the zero point of the X-axis (4 digits in mm)
Sensor
0
Set the distance (3 digits in mm) between the
photocells in the photocell array.
If the system Presence Sensor and Encoder are used,
set this parameter to 0.
Start
Start the Auto PackTrack procedure
Z Offset
0
Set a correction factor for the pack height (3 digits in
mm)
The Auto PackTrack procedure when run from the scanner keypad, requires a system reset
before the calibration is recognized. See the Auto PackTrack Setup procedure.
Version: the version of the PCT-8000 being used for calibration. This value can be read from
the barcode labels on the PCT-8000. Each label has the value vnnn where v is the version
number.
Cal Type: the XYZ calibration is forced. The coordinates for the three axes are calibrated.
NOTE
For Oscillating Mirror models the scan line must be parallel to the conveyor
direction and only the Y calibration will be performed, (the X and Z axes will
automatically be set to zero).
X Cal: the Absolute X position is forced. The X coordinate for all scanners is relative to the
precise point (PackTrack Reference Point X, Y, Z = 0).
X Offset: the X Offset moves the Absolute X coordinate (X, Y, Z= 0) for all the scanners to
the desired point along the X axis which will be measured in step 7 in par. 1.7.3.
Sensor: calibration will be performed either using the system Presence Sensor and Encoder
(most cases), or the PPA-8000 Photocell Array, for systems where the Presence Sensor or
Encoder are not present (typically Tilt-Tray or Cross-Belt applications).
NOTE
The Auto PackTrack procedure requires using the PPA-8000 Photocell
Array for all systems where either the Presence Sensor or the Encoder are
absent (including Continuous Operating Mode and Cargoscan applications).
If using the Presence Sensor and Encoder, the presence sensor must be connected to
the CBX100/500 Input 1 and in this menu Sensor is set to 0. The scanners Encoder Step
parameter must also be set correctly.
If using the PPA-8000, in this menu you must set Sensor (the Photocell distance) to 165
mm. The Photocell Array must be connected to the CBX100/500 I1 and I2 inputs (see the
relative installation manual), and the Encoder, if present, must be disconnected.
Z Offset (if necessary): for packs that are elevated above the conveyor surface (for example
on tilt trays), this parameter sets an offset for the height of a pack so that Z = 0 corresponds
to the bottom of the pack.
1.7.3 Auto PackTrack Setup
After setting the initial parameters in the PackTrack menu the Auto PackTrack setup
procedure can be started:
1. Press the ENT (enter) key at the Start item in the PackTrack menu.
2. Press the ENT (enter) key to confirm the action. The Master scanner sends the
message to the Slave scanners and the Display shows the Wait message.
After receiving the answer from all of the Slaves, the Master scanner shows the
status of each node (of each scanner of the cluster) as in the example below.
I
I
I
U
I
I
I
I
A
B
C
D
E
F
G H
The slave scanners are listed on the second line as letters (A, B, C, etc.).
On the first line above each scanner position a symbol indicates the scanner status
according to the following convention:
U
cannot be
calibrated
cannot be calibrated because not supported by scanner software version
U
can be
calibrated
can be calibrated but the calibration procedure fails either barcode reading or
verification
L
Lost
scanner stops responding during the procedure
I
Initial State
scanner ready to be calibrated
N
Not Verified scanner calibrated but not verified
C
Calibrated
scanner is calibrated
NOTE
If the network is made up of more than 16 slaves, you can use the ▲ (up
arrow) key to toggle between the lines.
3. At this point the Master scanner display allows to Continue or to Stop the procedure.
You can switch between the previous display windows using the ▲ (up arrow) key.
If there are any nodes that show as U or L, then you should Stop the procedure and
correct the problem.
If the nodes respond with I, N, or C then you can Continue with the procedure.
4. Press the ENT (enter) key to Continue the procedure. The Master scanner shows
message Let the parcel run.
5. Place the PCT-8000 onto the moving conveyor, before the PS Line (reference point)
and parallel to a conveyor edge (i.e. right-hand edge) with its arrow in the same
direction as the conveyor movement. Let it pass through the reading station. The
Master scanner shows the Wait message.
DS8100A REFERENCE MANUAL
10
1
Figure 2 - PCT-8000 First Run
After elaborating the passage of the parcel, the Master scanner again shows the
status of each node (of each scanner of the cluster) and then the Continue or Stop
screen.
6. Repeat steps 3 - 5 changing the PCT-8000 X position (i.e. always before the PS Line
(reference point) and parallel to a conveyor edge but changing to the left-hand edge
and/or to the center of the conveyor), until the procedure terminates.
Figure 3 - PCT-8000 Second and Third Runs
Typically 3 passes are necessary.
7. At the last step in the sequence the display prompts to place a barcode label
centered onto the physical X position (X Offset) on the conveyor. Press the ENT
(enter) key to Continue. You have 2 minutes to read the code before the procedure
ends automatically. Be careful that the barcode is not accidentally read in the act of
placing it at the desired X Offset position, and assure that it is read by only one
scanner (see the figure below). After placing the barcode label on the X coordinate,
you may have to pass your hand or other opaque object over it to end this step.
Figure 4 - X Offset Selection
Pressing the ▼ (down arrow) key at any point will terminate the procedure without
saving the Absolute X position alignment.
NOTE
Before resetting the Master scanner, if desired, you can download the Auto
PackTrack Report file from the Master scanner RAM by connecting it to
Genius™ and using the Tools>File transfer… menu. See Help On-Line.
8. Manually reset the Master scanner.
DS8100A REFERENCE MANUAL
12
1
1.8 ACCESSORIES
The following accessories are available on request for DS8100A:
Name
Description
Part Number
Power Supplies
PWR-120
J-box power unit 110/230 VAC 24 V 120 W
93ACC1530
PWR-240
J-box power unit 110/230 VAC 24 V 240 W
93ACC1070
PWR-480A
J-box power unit 110/230 VAC 24 V 480 W
93ACC1850
Cables and Terminators
BTK-8100
Bus terminator kit (5 pcs)
93ACC1090
BTK-8102
Double terminator kit (2 pcs)
93A051287
CAB-8100
10 wire shielded cable D 9.5 mm – 50 m
93ACC1120
CAB-8101
17-pin scanner/scanner connection cable 1.2 m
93A051020
CAB-8102
17-pin scanner/scanner connection cable 2.5 m
93A051030
CAB-8105
17-pin scanner/scanner connection cable 5 m
93A051040
CAB-8305
Power and bus return cable (last Slave) 5 m
93A051268
CAB-8310
Power and bus return cable (last Slave) 10 m
93A051336
CAB-8402
No power cable 2.5 m
93ACC1758
CAB-8405
No power cable 5 m
93ACC1759
CAB-F01
6K-8K FBUS cable to CBX 1 m
93A051355
CAB-F02
6K-8K FBUS cable to CBX 2 m
93A051356
CAB-F05
6K-8K FBUS cable to CBX 5 m
93A051357
CAB-6502
Fam 6K-8K cross cable 2.5 m
93A051288
CAB-6505
Fam 6K-8K cross cable 5 m
93A051289
CAB-8605
Power and Lonworks termination cable (Master) 5 m 93A051290
CAB-ETH-M01
M12-IP67 Ethernet Cable (1 m)
93A051346
CAB-ETH-M03
M12-IP67 Ethernet Cable (3 m)
93A051347
CAB-ETH-M05
M12-IP67 Ethernet Cable (5 m)
93A051348
CBL-1534-0.2
Ethernet Adapter Cable (M12 4-pin male to
RJ45 female)
93A050057
Software Management
Datalogic WebSentinel-005
Supervisor (up to 5 arrays)
93A101014
Datalogic WebSentinel-010
Supervisor (up to 10 arrays)
93A101015
Datalogic WebSentinel-020
Supervisor (up to 20 arrays)
93A101016
Datalogic WebSentinel-032
Supervisor (up to 32 arrays)
93A101017
Datalogic WebSentinel-064
Supervisor (up to 64 arrays)
93A101018
Datalogic WebSentinel-128
Supervisor (up to 128 arrays)
93A101019
Datalogic WebSentinel-256
Supervisor (up to 256 arrays)
93A101020
90° mirror close distance
93A201103
* Connection Boxes
CBX100
Compact Connection Box
93A301067
CBX500
Modular Connection Box
93A301068
CBX800
Gateway Connection Box
93A301077
BM100
Backup Module
93ACC1808
BA100
DIN Rail Adapters for CBX
93ACC1821
BA200
Bosch Adapters for CBX
93ACC1822
BA900
Two Cable Glands Panel
93ACC1847
Sensors
MEP-593
Photocell kit – PNP (PH-1)
93ACC1791
MEP-543
Photocell kit – NPN
93ACC1728
OEK-2
Optical encoder (10 m cable + spring)
93ACC1770
OEK-1
Optical encoder kit + 10 m cable
93ACC1600
Brackets
FBK-8100
Fast bracket kit (2 pcs)
93ACC1130
US-8100
Bracket kit (10 pcs)
93ACC1140
FS-1
Frame shaper (8 pcs)
93ACC1750
Miscellaneous
PLL-8000
Optocoupled PLL device
93ACC1280
ACS-81
Air cleaning system
93ACC1430
* DS8100A application software does not support any of the CBX500 Host Interface Module accessories nor the
BM150 Display accessory. Use the CBX800 Gateway for Host Interface Applications, (Fieldbus and non
Fieldbus).
DS8100A REFERENCE MANUAL
14
2
2 INSTALLATION
To install the system follow the given procedure:
1. Select the mounting location for DS8100A;
2. Mount the DS8100A scanner;
3. Position the scanner with respect to the barcode;
4. Proceed with system electrical connection;
5. Install the Genius™ program on the PC and configure the scanner.
WARNING
When installing several scanners, take care to position them correctly so
that no laser beam enters the reading window perpendicularly and at the
same level of the output beam of the other scanners. This condition could
occur more frequently for side mounted applications. If these precautions
are not followed, it may occur that the laser of the blinded scanner starts
blinking due to an internal circuit which temporarily turns the laser off when
detecting a power anomaly. To resolve this problem, it is sufficient to slightly
change the inclination and position of one of the two scanners involved.
NOTE
Refer to the Reference Documentation for details on connecting your
DS8100A reader to other devices in the system (i.e. CBX100 etc.).
2.1 PACKAGE CONTENTS
Verify that the DS8100A reader and all the parts supplied with the equipment are present
and intact when opening the packaging; the list of parts includes:
DS8100A reader
Installation Quick Reference + barcode test chart
DS8100A configuration CD-ROM
Mounting bracket and screws
Figure 5 - DS8100A Package Contents
2.2 MECHANICAL MOUNTING
2.2.1 Mounting the Scanner
DS8100A can be installed to operate in any position. There are 16 screw holes (M6 X 8) on
the sides of the scanner for mounting. The diagram below can be used for installation; refer to
par. 4.6 and par. 9.4 for correct positioning of the scanner with respect to the reading zone and
scanner orientation.
126.6
[4.98]
172.5
[6.79]
217
[8.54]
45°
67.5
[2.66]
50
[1.97]
46.7
[1.84]
50
[1.97]
45°
M6 N°16
mm
inch
67.5
[2.66]
46.8
[1.84]
Figure 6- DS8100A Overall Dimensions
164
6.45
R 15
0.59
5
0.19
164
6.45
100
3.93
30
1.18
16
0.63
48
1.88
R 15 N°4
0.59
80
3.15
100
3.93
15
0.59
17.5
0.68
45
1.77
8.5 N° 4
0.33
mm
inch
Figure 7– ST-163 Mounting Bracket Overall Dimensions
DS8100A REFERENCE MANUAL
16
2
192.3
[7.57]
275.1
[10.83]
254
[10.00]
28°
45°
67.5
[2.66]
50
[1.97]
46.7
[1.84]
50
[1.97]
45°
mm
inch
67.5
[2.66]
46.8
[1.84]
Figure 8 - DS8100A Oscillating Mirror Model Overall Dimensions
2.2.2 Mounting the Scanner with Accessories
The following accessories allow installing the DS8100A reader in the most suitable position
for your network layout:
-
ST-163 mounting bracket;
-
FBK-8100 fast bracket.
The ST-163 is a 90° mounting bracket to be mounted on the reader as displayed in the
image below:
Figure 9 – Mounting the ST-163 Mounting Bracket
The FBK-8100 is a fast bracket kit allowing quick and easy mounting of the scanner on the
ST-163 bracket. It is particularly useful when performing a scanner automatic replacement
(see par. 10.2), since the scanner can be simply substituted with a new one while
maintaining its physical position within the network.
First, it is necessary to fix the FBK-8100 round piece (2) to the ST-163 bracket (already
mounted to the reading station frame) by means of the two screws (C). Then, give the
scanner the correct orientation and fix it to the FBK-8100 cross piece (1) through the two
screws (B). Finally, attach the assembly to the ST-163 bracket by making the FBK-8100
cross piece (1) slide into the round piece (2) and fix it by tightening the screws (A).
Figure 10 – Mounting the FBK-8100 and ST-163 Brackets on the Scanner
Thanks to the FBK-8100 it always possible to substitute a mounted scanner with a new one
by simply:
unscrewing the two screws (A) fixing the FBK-8100 cross piece to the FBK-8100 round
piece;
sliding the cross piece (still mounted on the scanner to be substituted) out of the round
piece;
remounting the cross piece onto the new scanner with the correct orientation;
inserting and tightening the two screws (A).
Figure 11 – Substituting a Scanner
A
A
1
2
B
C
M6 x 14 with flat washers
M6 x 14 with flat washers
M6 x 12 with lock washers
DS8100A REFERENCE MANUAL
18
2
2.3 POSITIONING THE SCANNER
The DS8100A scanner is able to decode barcode labels at a variety of angles, however
significant angular distortion may degrade reading performance.
When mounting the DS8100A take into consideration these three ideal label position angles:
Pitch 0°, Skew 0° to 45° and Tilt 0°.
Follow the suggestions for the best orientation:
The Pitch angle is represented by the value P in Figure 12. Position the reader in order to
minimize the Pitch angle.
Figure 12 - "Pitch" angle
The Skew angle is represented by the value S in Figure 13.
Figure 13 - "Skew" angle
The Tilt angle is represented by the value T in Figure 14. For code reconstruction see par. 9.1.
Figure 14 – "Tilt" angle
P
S
T
CBX ELECTRICAL CONNECTIONS
19
3
3 CBX ELECTRICAL CONNECTIONS
Each scanner model has the following connectors:
Scanner Model
Connectors
Standard
26-pin male serial interface and I/O connector
17-pin male Lonworks connector
17-pin female Lonworks connector
Ethernet
26-pin male serial interface and I/O connector
17-pin male Lonworks connector
17-pin female Lonworks connector
M12 4-pin D-coded connector for Ethernet *
* older models have RJ45 Industrial modular connector
All DS8100A models can connect their 26-pin male D-sub connector for connection to the
power supply, serial interface and input/output signals to a CBX connection box by using the
dedicated cables (CAB-F0x).
We recommend making system connections through one of the CBX connection boxes since
they offer the advantages of easy connection, easy device replacement and filtered
reference signals.
NOTE
If you require direct wiring to the scanner the details of the connector pins
and relative connections are indicated in Chaper 4.
For Lonworks network connections see chapters 5 and 7.
For Fieldbus connections see chapters 6 and 7.
For ID-NET™ Fixed Baudrate connections see the Application Note on the CD-ROM.
DS8100A REFERENCE MANUAL
20
3
The table below gives the pinout of the CBX100/500 terminal block connectors. Use this
pinout when the DS8100A reader is connected by means of the CBX100/500:
CBX100/500 Terminal Block Connectors
Group
Name
Function
Input Power
Vdc
Power Supply Input Voltage +
GND
Power Supply Input Voltage -
Earth
Protection Earth Ground
External Trigger
(PS) Input
+V
Power Source – External Trigger
I1A
External Trigger A (polarity insensitive) for PS
I1B
External Trigger B (polarity insensitive) for PS
-V
Power Reference – External Trigger
Encoder or
Generic Input
+V
Power Source – Inputs
I2A
Input 2A (polarity insensitive) for Encoder
I2B
Input 2B (polarity insensitive) for Encoder
-V
Power Reference – Inputs
Outputs
+V
Power Source – Outputs
-V
Power Reference – Outputs
O1+
Output 1+
O1-
Output 1-
O2+
Output 2+
O2-
Output 2-
Other I/O
(CBX500 only)
O3A
Output 3A (polarity insensitive)
O3B
Output 3B (polarity insensitive)
+V
Power Source – Other I/O
I3A
Input 3A (polarity insensitive)
I4A
Input 4A (polarity insensitive)
-V
Power Reference – Other I/O
I34B
Input 3B and 4B (common) (polarity insensitive)
I34B
Input 3B and 4B (common) (polarity insensitive)
Auxiliary Interface
TX
Auxiliary Interface TX
RX
Auxiliary Interface RX
SGND
Auxiliary Interface Reference
ID-NET™
REF
Reserved
ID+
Reserved
ID-
Reserved
Network
Shield
Network Cable Shield
RS232
RS485FD
RS485HD
Main Interface
TX
TX+
RTX+
RTS
TX-
RTX-
RX
*RX+
CTS
*RX-
SGND
SGND
SGND
* Do not leave floating, see par. 3.2.2 for connection details.
CAUTION
Do not connect GND and SGND to different (external) ground references.
GND and SGND are internally connected through filtering circuitry which
can be permanently damaged if subjected to voltage drops over 0.8 Vdc.
CAUTION
DS8100A scanners do not support Host Interface Modules with the
CBX500. Use the CBX800 Gateway for Host Interface Applications,
(Fieldbus and non Fieldbus).
CBX ELECTRICAL CONNECTIONS
21
3
NOTE
To avoid electromagnetic interference when the scanner is connected to a
CBX connection box, verify the jumper positions in the CBX as indicated in
its Installation Manual.
3.1 POWER SUPPLY
Power can be supplied to the scanner through the CBX100/500 spring clamp terminal pins
as shown in Figure 15:
V+
in
Earth
Ground
Power Supply
VGND
Figure 15 - Power Supply Connections
The power must be between 20 and 30 Vdc only. The max. power consumption is 30 W
including startup current.
Several accessory power supplies are available to power the DS8100A(s) and reading
station components. See par. 1.8.
A security system allows the laser to activate only once the motor has reached the correct
rotational speed; consequently, the laser beam is generated after a slight delay from the
power on of the scanner.
It is recommended to connect the device CHASSIS to earth ground (Earth) by setting the
appropriate jumper in the CBX connection box. See the CBX Installation Manual for details.
3.2 MAIN SERIAL INTERFACE
The main serial interface is compatible with the following electrical standards and the relative
signals are available on the CBX spring clamp terminal blocks:
RS232
RS485 full-duplex
RS485 half-duplex
The main interface type and the relative parameters (baud rate, data bits, etc.) can be
set using the Genius™ utility program or the Genius™ based Host Mode Programming
procedure. For more details refer to the section "Main Serial Port" in the Genius™
Help On Line.
DS8100A REFERENCE MANUAL
22
3
3.2.1 RS232 Interface
The main serial interface is used in this case for point-to-point connections; it handles
communication with the host computer and allows both transmission of code data and
configuring the scanner. This is the default setting.
The following pins are used for RS232 interface connection:
CBX100/500
Function
TX
Transmit Data
RX
Receive Data
RTS
Request To Send
CTS
Clear To Send
SGND
Signal Ground
It is always advisable to use shielded cables. If the shield is tied to ground at the Host, then
leave it floating at the CBX. If it is floating at the Host then tie it to Shield at the CBX. The
overall maximum cable length must be less than 15 m (50 ft).
SGND RXD
TXD
CTS
RTS
USER INTERFACE
SGND TX
RX
RTS
CTS
SCANNER
Figure 16 – RS232 Main Interface Connections Using Hardware Handshaking
START
OF
TRANSMISSION
END
OF
TRANSMISSION
+ V
RTS
- V
+ V
TX DATA
- V
+ V
CTS
- V
DATA
TRANSMISSION
DATA
TRANSMISSION
C1
C2
C4
C3
C5
TRANSMISSION
STOPPED
ENABLED
DISABLED
ENABLED
IDLE
IDLE
Figure 17 - RS232 Control Signals
The RTS and CTS signals control data transmission and synchronize the connected devices.
If the RTS/CTS handshaking protocol is enabled, the DS8100A activates the RTS output to
indicate a message is to be transmitted. The receiving unit activates the CTS input to enable
the transmission.
CBX ELECTRICAL CONNECTIONS
23
3
3.2.2 RS485 Full-Duplex Interface
The RS485 full-duplex (5 wires + shield) interface is used for non-polled communication
protocols in point-to-point connections over longer distances (max 1200 m / 3940 ft) than
those acceptable for RS232 communications or in electrically noisy environments.
If the shield is tied to ground at the Host, then leave it floating at the CBX. If it is floating at
the Host then tie it to Shield at the CBX.
The CBX pinout follows:
CBX100/500
Function
TX+
RS485 Transmit Data +
RX+
RS485 Receive Data +
TX-
RS485 Transmit Data -
RX-
RS485 Receive Data -
SGND
Signal Ground
RX485+ TX485+
SGND
RX485-
TX485-
USER INTERFACE
SGND TX+
RX+
TX-
RX-
SCANNER
Figure 18 - RS485 Full-duplex Connections
NOTE
For applications that do not use RX485 signals, do not leave these lines
floating but connect them to SGND as shown below.
RX485+
SGND
RX485-
USER INTERFACE
SGND TX+
TX-
SCANNER
Figure 19 - RS485 Full-duplex Connections using Only TX Signals
DS8100A REFERENCE MANUAL
24
3
3.2.3 RS485 Half-Duplex Interface
NOTE
This interface is provided for backward compatibility. We recommend using
the more efficient Lonworks network for Master/Slave or Multiplexer layouts.
The RS485 half-duplex (3 wires + shield) interface is used for polled communication
protocols.
It can be used for Multidrop connections with a Datalogic Multiplexer, (see par. "Multiplexer"
in Appendix A) exploiting a proprietary protocol based on polled mode called MUX32
protocol, where a master device polls slave devices to collect data. The overall maximum
cable length should not exceed 1200 m (3940 ft).
If the shield is tied to ground at the Host, then leave it floating at the CBX. If it is floating at
the Host then tie it to Shield at the CBX.
CBX100/500
Function
RTX+
RS485 Receive/Transmit Data +
RTX-
RS485 Receive/Transmit Data -
SGND
Signal Ground
RTX485+
SGND
RTX485-
USER INTERFACE
SGND RTX+
RTX-
SCANNER
Figure 20 - RS485 Half-duplex Connections
This interface is forced by software when the protocol selected is MUX32 protocol.
In a Multiplexer layout, the Multidrop address must also be set via serial channel by the
Genius™ utility or by the Host Programming Mode.
Figure 21 shows a multidrop configuration with DS8100A scanners connected to a
Multiplexer.
CAUTION
This is an example of multidrop wiring. Consult the multiplexer manual for
complete wiring instructions.
CBX ELECTRICAL CONNECTIONS
25
3
#1
#0
(up to 31)
Scanner
Scanner
Scanner
Slave
Slave
Slave
Main Interface
RS232/RS485
HOST
Multidrop GND
Shield
Multidrop -
Multidrop +
1200 m Max Length
Multidrop Cable
V+
V-
Vdc
Earth
GND
Vdc
Earth
GND
Vdc
Earth
GND
PG-6000
PG-6000
PG-6000
PG-6000
MULTIPLEXER
Shield to Earth
120 Ohm
CBX100/500
Shield
floating
CBX100/500
Shield
floating
CBX100/500
SGND
Shield
RTX-
RTX+
SGND
Shield
RTX-
RTX+
SGND
Shield
RTX-
RTX+
Shield
floating
RS485 HD
Termination Resistor. OFF
RS485 HD
Termination Resistor. OFF
RS485 HD
Termination Resistor. ON
Figure 21 - DS8100A Multidrop Connection to a Multiplexer
* When using CBX500, the Main interface multidrop network signals: Shield, SGND, RTX+and RTX- are
repeated on terminal connector row 4 to facilitate system cabling.
*
*
DS8100A REFERENCE MANUAL
26
3
3.3 AUXILIARY RS232 INTERFACE
The auxiliary serial interface is used exclusively for RS232 point-to-point connections. It is
principally used for scanner configuration from a laptop PC but is also available for LOCAL
ECHO to a monitoring PC or for Pass through layouts. This interface is active when the Data
Tx parameter is enabled.
The parameters relative to the aux interface (baud rate, data bits, etc.) can be defined using
the Genius™ utility program or Genius™ based Host Mode Programming installed from the
CD-ROM.
The 9-pin female Auxiliary Interface connector inside the CBX is the preferred connector for
device configuration or temporary communication monitoring.
5
1
6
9
Figure 22 - 9-pin female connector
If permanent system wiring is required, the following pins are used to connect the RS232
auxiliary interface. The overall maximum cable length should not exceed 15 m (50 ft). In this
case it is advisable to use shielded cables. If the shield is tied to ground at the Host, then
leave it floating at the CBX. If it is floating at the Host then tie it to Shield at the CBX.
CBX100/500
Function
RX
Auxiliary Interface Receive Data
TX
Auxiliary Interface Transmit Data
SGND
Auxiliary Interface Reference
RX TX
Reference
USER INTERFACE
Figure 23 - RS232 Auxiliary Interface Connections
NOTE
Do not connect the Aux Interface to the CBX spring clamp connectors and
the 9-pin connector simultaneously.
CBX ELECTRICAL CONNECTIONS
27
3
3.4 INPUTS
There are four optocoupled polarity insensitive inputs available on the scanner: Input 1
(External Trigger/PS), Input 2 (Encoder), Input 3 and 4 generic inputs.
The electrical features of the inputs are:
Maximum voltage:
30 Vdc
Maximum current Input 1 and 2:
12 mA (scanner) + 12 mA (CBX)
Maximum current Input 3 and 4:
12 mA (scanner)
CBX100/500
Function
+V
Power Source - External Trigger
I1A
External Trigger A (polarity insensitive) for PS
I1B
External Trigger B (polarity insensitive) for PS
I2A
Input 2 A (polarity insensitive) for Encoder
I2B
Input 2 B (polarity insensitive) for Encoder
I3A (CBX500 only)
Input 3 A (polarity insensitive)
I4A (CBX500 only)
Input 4 A (polarity insensitive)
I34B (CBX500 only)
Common Reference for Inputs 3 and 4 (polarity insensitive)
-V
Power Reference - External Trigger
The active state of all the inputs is selected in software (open or closed). Refer to the
Genius™ Help On Line.
All inputs are optocoupled, polarity insensitive, and driven by a constant current generator;
the command signal is filtered through an anti-disturbance circuit which generates a
debouncing delay which can be set to 5 ms or 500 s. In particular, I1 for PS, I3 and I4 share
the same value which usually corresponds to 5 ms when using a photoelectric sensor, while
I2 is set to 500 s when this input is used for the Encoder. The maximum Encoder frequency
is 2 kHz.
Input 1 (External Trigger/PS) is used in the On-Line and PackTrack™ operating Modes and
tells the scanner to scan for a code. The yellow Phase On LED (Figure C, 3) which refers to
Input 1 is on only when current flows through the input circuit and therefore when the active
state of this input is set to "active open", the LED lights up when the input corresponds to
OFF.
Input 2 is normally used for the Encoder input. In PackTrack™ mode, it detects the conveyor
speed.
Inputs 3 and 4 can be used as the stop signal for the reading phase.
The debouncing delay value can be changed through the software parameter Debouncing for
Input x, see the "6-8 K Software Configuration Parameter Guide” or Help file.
Powering Inputs
Input devices can be supplied by either scanner power (V+ and V-) or external power
supplies (Vext).
Electrical isolation between the input command logic and the scanner is maintained when
powering the input devices from an external supply voltage (Vext).
DS8100A REFERENCE MANUAL
28
3
The driving logic of the input signals may be powered, for convenience, with the voltage
supply at the CBX terminal block spring clamps (V+) and (V-). In this case, however, the
device is no longer electrically isolated. The voltage available on pins V+ and V-, is physically
the same as the input power for the scanner (Vdc and GND).
INPUT 1 (EXTERNAL TRIGGER/PS) CONNECTIONS USING DS8100A POWER
(brown)
(black)
(blue)
MEP-593 PH-1 Photocell (PNP)
Figure 24 – MEP-593 PH-1 (PNP) External Trigger/PS Using DS8100A Power
Power to
Input
Photocell
Signal
Photocell
Reference
NPN Photocell
Figure 25 - NPN External Trigger/PS Using DS8100A Power
INPUT 1 (EXTERNAL TRIGGER/PS) CONNECTIONS USING EXTERNAL POWER
External Device
Ground Reference
Input
Signal
Figure 26 - PNP External Trigger/PS Using External Power (i.e. PLC signal)
External Device
Power Reference
Input
Signal
Figure 27 - NPN External Trigger/PS Using External Power (i.e. PLC signal)
CBX ELECTRICAL CONNECTIONS
29
3
INPUT 2 (ENCODER) CONNECTIONS USING DS8100A POWER
(red)
(white)
OEK-1 Encoder (PNP)
(black)
Figure 28 - OEK-1 Encoder PNP Using DS8100A Power
Power to
Input
Input Device Signal
Input Device
Reference
Input Device (Encoder)
Figure 29 - Encoder NPN Using DS8100A Power
INPUT 2 (ENCODER) CONNECTIONS USING EXTERNAL POWER
External Device
Ground Reference
Input
Signal
Figure 30 - PNP Encoder Using External Power (i.e. PLC signal)
External Device
Power Reference
Input
Signal
Figure 31 - NPN Encoder Using External Power (i.e. PLC signal)
DS8100A REFERENCE MANUAL
30
3
NOTE
Terminal pins I34B are common to both inputs 3 and 4 and therefore these
inputs cannot be driven by opposite polarity devices.
INPUT 3 - 4 CONNECTIONS USING DS8100A POWER (CBX500 Only)
Power to
Input Device
Input
Input Device
Signal
Reference
Input Device
Figure 32 - PNP Input 3 - 4 Using DS8100A Power
Power to
Input
Input Device
Signal
Input Device
Reference
Input Device
Figure 33 - NPN Input 3 - 4 Using DS8100A Power
INPUT 3 - 4 CONNECTIONS USING EXTERNAL POWER (CBX500 Only)
Input
Signal
External Device
Ground Reference
Figure 34 - PNP Input 3 - 4 Using External Power (i.e. PLC signal)
Input
Signal
External Device
Power Reference
Figure 35 - NPN Input 3 - 4 Using External Power (i.e. PLC signal)
CBX ELECTRICAL CONNECTIONS
31
3
3.4.1 Code Verifier
If the DS8100A is used as a Code Verifier, the verifier code can be configured in software
through the Genius™ configuration program. However it is also possible to use one of the
inputs to trigger when the scanner should store a code read as the verifier code.
The Code Verifier parameter must be enabled, and the configuration parameters to allow
correct Code Type reading must be saved to the scanner in order to read the verifier code.
When the selected input is activated, the next read code will be stored as the verifier code in
the scanner's non-volatile (Flash) memory.
For more details see the Verifier Parameters in the "6-8 K Software Configuration Parameter
Guide” or Help file.
3.5 OUTPUTS
Three general purpose outputs are available. The electrical features are given below:
Outputs 1 and 2
Maximum Voltage
30 V
Collector Current (pulse)
130 mA Max.
Collector Current (continuous)
40 mA Max.
Saturation Voltage (VCE)
1 V at 10 mA Max.
Maximum Power Dissipation
90 mW at 50°C (Ambient temperature)
Output 3 has different electrical features. It is a bi-directional solid state relay with built-in
current limit protection.
Output 3
Maximum Voltage
± 100 V (Vext only)
Collector Current (pulse)
300 mA Max. at 25°C (Ambient temperature)
240 mA Max. at 50°C (Ambient temperature)
Collector Current (continuous)
200 mA Max. at 25°C (Ambient temperature)
150 mA Max. at 50°C (Ambient temperature)
R on
R off
6 – 15 Ω
> 500 Ω
Off-State Leakage Current
< 1 µA
Maximum Power Dissipation
550 mW at 50°C (Ambient temperature)
CBX100/500
Function
+V
Power Source - Outputs
O1+
Output 1 +
O1-
Output 1 -
O2+
Output 2 +
O2-
Output 2 -
O3A (CBX500 only)
Output 3 A (polarity insensitive)
O3B (CBX500 only)
Output 3 B (polarity insensitive)
-V
Power Reference Outputs
DS8100A REFERENCE MANUAL
32
3
The function of each output can be defined by the user (No Read, Right, Wrong, etc.). Refer
to the Genius™ Help On Line.
The output signals are fully programmable being determined by the configured
Activation/Deactivation events, Deactivation Timeout or a combination of the two.
By default, Output 1 is associated with the Complete Read event, which activates when all
the selected codes are correctly decoded, and Output 2 is associated with the No Read
event, which activates when the code signaled by the external trigger/PS is not decoded.
Output 3 can be assigned to the same events and it has the advantage of being polarity
insensitive. By default it is not assigned to any event. The CBX500 must be used to connect
this output.
OUTPUT 1 and 2 CONNECTIONS USING DS8100A POWER
Power to
Output
Output Device
Signal
Output Device
Reference
Output Device
Figure 36 - Open Emitter Output Using DS8100A Power
Power to
Output Device
Output Device
Reference
Output Device
Output
Signal
Figure 37 - Open Collector Output Using DS8100A Power
CBX ELECTRICAL CONNECTIONS
33
3
OUTPUT 1 and 2 CONNECTIONS USING EXTERNAL POWER
Output Device
Power Reference
Output
Signal
Output Device
Figure 38 - Open Emitter Output Using External Power
Output Device
Ground Reference
Output
Signal
Output Device
Figure 39 - Open Collector Output Using External Power
OUTPUT 3 CONNECTIONS USING DS8100A POWER (CBX500 Only)
Power to
Output Device
Output
Output Device
Signal
Reference
Output Device
Figure 40 - Output 3 Using DS8100A Power
Power to
Output Device
Output
Output Device
Signal
Ground Reference
Output Device
Figure 41 - Output 3 Using DS8100A Power
DS8100A REFERENCE MANUAL
34
3
OUTPUT 3 CONNECTIONS USING EXTERNAL POWER (CBX500 Only)
Output
Signal
External Device
Power or Ground Reference
Figure 42 - Ouput 3 Using External Power
The command signals are filtered and generate a delay of about 50 µs for Output 1 and 2
and 1 ms for Output 3.
3.6 USER INTERFACE - HOST
The following table contains the pinout for standard RS232 PC Host interface. For other user
interface types please refer to their own manual.
RS232 PC-side connections
1
5
9
6
9-pin male connector
13
25
14
1
25-pin male connector
Pin
Name
Pin
Name
2
RX
3
RX
3
TX
2
TX
5
GND
7
GND
7
RTS
4
RTS
8
CTS
5
CTS
CUSTOM CABLE ELECTRICAL CONNECTIONS
35
4
4 CUSTOM CABLE ELECTRICAL CONNECTIONS
Each scanner model has the following connectors:
Scanner Model
Connectors
Standard
26-pin male serial interface and I/O connector
17-pin male Lonworks connector
17-pin female Lonworks connector
Ethernet
26-pin male serial interface and I/O connector
17-pin male Lonworks connector
17-pin female Lonworks connector
M12 4-pin D-coded connector for Ethernet *
* older models have RJ45 Industrial modular connector
All DS8100A models are equipped with a 26-pin male D-sub connector for connection to the
host computer, power supply and input/output signals. These signals can be wired using a
custom cable according to the application needs.
The paragraphs in this chapter detail the individual signal connections.
For Lonworks network connections see chapters 5 and 7.
For Fieldbus connections see chapters 6 and 7.
For ID-NET™ Fixed Baudrate connections see the Application Note on the CD-ROM.
DS8100A REFERENCE MANUAL
36
4
The details of the connector pins are indicated in the following table:
10
19
1
18
9
26
Figure 43 - 26-pin Connector
DS8100A 26-pin D-sub Connector Pinout
Pin
Name
Function
1
CHASSIS
Chassis - internally connected to GND
Cable shield connected to chassis
20
RX
Receive Data of Auxiliary RS232 (referred to GND)
21
TX
Transmit Data of Auxiliary RS232 (referred to GND)
8
O1+
Configurable Digital Output 1 - positive pin
22
O1-
Configurable Digital Output 1 - negative pin
11
O2+
Configurable Digital Output 2 - positive pin
12
O2-
Configurable Digital Output 2 - negative pin
16
O3A
Configurable Digital Output 3 - polarity insensitive
17
O3B
Configurable Digital Output 3 - polarity insensitive
18
I1A
External Trigger (polarity insensitive) for PS
19
I1B
External Trigger (polarity insensitive) for PS
6
I2A
Input Signal 2 (polarity insensitive) for Encoder
10
I2B
Input Signal 2 (polarity insensitive) for Encoder
14
I3A
Input Signal 3 (polarity insensitive)
15
I4A
Input Signal 4 (polarity insensitive)
24
I34B
Common reference of Input 3 and Input 4 (polarity insensitive)
9,13
Vdc
Power Supply Input Voltage +
23,25,26
GND
Power Supply Input Voltage -
Main Interface Connector Pinout
Pin
RS232
RS485
Full Duplex
RS485
Half Duplex
2
TX
TX+
RTX+
3
RX
*RX+
4
RTS
TX-
RTX-
5
CTS
*RX-
7
GND_ISO
GND_ISO
GND_ISO
* Do not leave floating, see par. 4.2.2 for connection details.
CUSTOM CABLE ELECTRICAL CONNECTIONS
37
4
4.1 POWER SUPPLY
The supply voltage for correct operation of the scanner must be between 20 and 30 Vdc. The
max. power consumption is 30 W including startup current.
Several accessory power supplies are available to power the DS8100A(s) and reading
station components. See par. 1.8.
A security system allows the laser to activate only once the motor has reached the correct
rotational speed; consequently, the laser beam is generated after a slight delay from the
power on of the scanner.
Note that GND is internally connected to chassis. The cable shield is also connected to pin 1
- CHASSIS.
DS8100A
USER INTERFACE
23/25
GND
V- (Ground)
V+ (20 – 30 Vdc)
VS
9/13
CHASSIS
1
Earth Ground
Chassis
Figure 44 – Power Supply Using the 26-pin Connector
4.2 MAIN SERIAL INTERFACE
The main serial interface is compatible with the following electrical standards:
RS232
RS485 full-duplex
RS485 half-duplex
The main interface type and the relative parameters (baud rate, data bits, etc.) can be
set using the Genius™ utility program or the Genius™ based Host Mode Programming
procedure. For more details refer to the section "Main Serial Port" in the Genius™
Help On Line.
DS8100A REFERENCE MANUAL
38
4
4.2.1 RS232 Interface
The main serial interface is used for communication with the Host computer and allows both
transmission of code data and configuring the scanner. The overall maximum cable length
should not exceed 15 m (50 ft).
The following pins of the 26-pin connector are used for RS232 interface connection:
Pin
Name
Function
2
TX
Transmit
3
RX
Receive
4
RTS
Request to send
5
CTS
Clear to send
7
GND_ISO
Main signal ground
DS8100A
7
GND_ISO
SGND Main Isolated
USER INTERFACE
RTS
4
CTS
5
RX
3
RXD
TX
2
TXD
1
Earth
Ground
CHASSIS
Figure 45 - RS232 Connections
START
OF
TRANSMISSION
END
OF
TRANSMISSION
+ V
RTS
- V
+ V
TX DATA
- V
+ V
CTS
- V
DATA
TRANSMISSION
DATA
TRANSMISSION
C1
C2
C4
C3
C5
TRANSMISSION
STOPPED
ENABLED
DISABLED
ENABLED
IDLE
IDLE
Figure 46 - RS232 Control Signals
The RTS and CTS signals control data transmission and synchronize the connected devices.
If the RTS/CTS hardware protocol is enabled, the DS8100A activates the RTS output to
indicate a message can be transmitted. The receiving unit must activate the CTS input to
enable the transmission.
CUSTOM CABLE ELECTRICAL CONNECTIONS
39
4
4.2.2 RS485 Full-Duplex Interface
The RS485 full-duplex (5 wires + shield) interface is used for non-polled communication
protocols in point-to-point connections over longer distances than those acceptable for
RS232 communications or in electrically noisy environments. The overall maximum cable
length should not exceed 1200 m (3940 ft).
The following pins of the 26-pin connector are used for RS485 full-duplex interface connection:
Pin
Name
Function
2
TX+
RS485 output (+)
3
RX+
RS485 input (+)
4
TX-
RS485 output (-)
5
RX-
RS485 input (-)
7
GND_ISO
Main signal ground
DS8100A
7
GND_ISO
TX485+
2
TX485-
4
RX485+
3
RX485-
5
+
SGND Main Isolated
USER INTERFACE
RX485
1
Earth
Ground
CHASSIS
-
+
TX485
-
Figure 47 - RS485 Full-Duplex Interface Connections
NOTE
For applications that do not use RX485 signals, do not leave these lines
floating but connect them to GND_ISO as shown below.
DS8100A
7
GND_ISO
TX485+
2
TX485-
4
RX485+
3
RX485-
5
+
SGND Main Isolated
USER INTERFACE
RX485
1
Earth
Ground
CHASSIS
-
Figure 48 - RS485 Full-duplex Connections using Only TX Signals
DS8100A REFERENCE MANUAL
40
4
4.2.3 RS485 Half-Duplex Interface
NOTE
This interface is provided for backward compatibility. We recommend using
the more efficient Lonworks network for Master/Slave or Multiplexer layouts.
The RS485 half-duplex (3 wires + shield) interface can be used for polled communication
protocols.
It can be used for Multidrop connections with a Datalogic Multiplexer, (see par. "Multiplexer"
in Appendix A) exploiting a proprietary protocol based on polled mode called MUX32
protocol, where a master device polls slave devices to collect data. The overall maximum
cable length should not exceed 1200 m (3940 ft).
The following pins of the 26-pin connector are used for RS485 half-duplex interface
connection:
Pin
Name
Function
2
RTX+
RS485 input/output (+)
4
RTX-
RS485 input/output (-)
7
GND_ISO
Main signal ground
DS8100A
7
GND_ISO
RTX485+
2
RTX485-
4
RS485REF
MULTIPLEXER
RTX485-
RTX485+
1
Earth
Ground
CHASSIS
Figure 49 – RS485 Half-Duplex Interface Connections
This interface is forced by software when the protocol selected is MUX32 protocol.
In a Multiplexer layout, the Multidrop address must also be set via serial channel by the
Genius™ utility or by the Host Programming Mode.
Figure 50 shows a multidrop configuration with DS8100A scanners connected to a
Multiplexer.
CAUTION
This is an example of multidrop wiring. Consult the multiplexer manual for
complete wiring instructions.
CUSTOM CABLE ELECTRICAL CONNECTIONS
41
4
Figure 50 – DS8100A Multidrop Connection to a Multiplexer
DS8100A REFERENCE MANUAL
42
4
4.3 AUXILIARY INTERFACE
The auxiliary serial interface is used exclusively for RS232 point-to-point connections. It is
principally used for scanner configuration from a laptop PC but is also available for LOCAL
ECHO to a monitoring PC or for Pass through layouts. This interface is active when the Data
Tx parameter is enabled. The overall maximum cable length should not exceed 15 m (50 ft).
The following pins of the 26-pin connector are used for RS232 full-duplex interface
connection:
Pin
Name
Function
20
RX
Receive data
21
TX
Transmit data
23
GND
Common Ground
DS8100A
USER INTERFACE
23
GND
GND
TXD
RXAUX
20
RXD
TXAUX
21
1
Earth
Ground
CHASSIS
Figure 51 - RS232 Auxiliary Interface Connections
4.4 INPUTS
There are four optocoupled polarity insensitive inputs available on the 26-pin connector of
the DS8100A scanner: Input 1 (External Trigger/PS), Input 2 (Encoder), Input 3 and 4
generic inputs:
The electrical features of these inputs are:
Maximum voltage
30 Vdc
Maximum current all Inputs:
12 mA
Pin
Name
Function
18
I1A
External Trigger (polarity insensitive) for PS
19
I1B
External Trigger (polarity insensitive) for PS
6
I2A
Input Signal 2 (polarity insensitive) for Encoder
10
I2B
Input Signal 2 (polarity insensitive) for Encoder
14
I3A
Input Signal 3 (polarity insensitive)
15
I4A
Input Signal 4 (polarity insensitive)
24
I34B
Common Reference of Input 3 and Input 4 (polarity insensitive)
The active state of all the inputs is selected in software (open or closed). Refer to the
Genius™ Help On Line.
All inputs are optocoupled, polarity insensitive, and driven by a constant current generator;
the command signal is filtered through an anti-disturbance circuit which generates a
debouncing delay which can be set to 5 ms or 500 s. In particular, I1 for PS, I3 and I4 share
CUSTOM CABLE ELECTRICAL CONNECTIONS
43
4
the same value which usually corresponds to 5 ms when using a photoelectric sensor, while
I2 is set to 500 s when this input is used for the Encoder. The maximum Encoder frequency
is 2 kHz.
Input 1 (External Trigger/PS) is used in the On-Line and PackTrack™ operating Modes and
tells the scanner to scan for a code. The yellow Phase On LED (Figure C, 3) which refers to
Input 1 is on only when current flows through the input circuit and therefore when the active
state of this input is set to "active open", the LED lights up when the input corresponds to
OFF.
Input 2 is normally used for the Encoder input. In PackTrack™ mode, it detects the conveyor
speed.
Inputs 3 and 4 can be used as the stop signal for the reading phase.
The debouncing delay value can be changed through the software parameter Debouncing for
Input x, see the "6-8 K Software Configuration Parameter Guide” or Help file.
Powering Inputs
Input devices can be supplied by either scanner power (Vdc and GND) or external power
supplies (Vext).
Electrical isolation between the input command logic and the scanner is maintained when
powering the input devices from an external supply voltage (Vext).
The driving logic of the input signals may be powered, for convenience, with the voltage
supply between pins 9 (Vdc) and 23 (GND) of the 26-pin I/O connector. In this case,
however, the device is no longer electrically isolated. The voltage available on the 26-pin I/O
connector, is physically the same as used to power the scanner.
INPUT 1 - 2 CONNECTIONS USING DS8100A POWER
EXTERNAL TRIGGER/ENCODER
DS8100A
+ 5V
A/B
B/A
GND
V
~
~
+
-
VS
Ground
Figure 52 - PNP Command Input Connection Using Scanner Power
EXTERNAL TRIGGER/ENCODER
DS8100A
A/B
B/A
GND
V
+ 5V
~
~
+
-
Ground
VS
Figure 53 - NPN Command Input Connection Using Scanner Power
DS8100A REFERENCE MANUAL
44
4
INPUT 1 - 2 CONNECTIONS USING EXTERNAL POWER
EXTERNAL TRIGGER/ENCODER
DS8100A
+ 5V
A/B
Vext
B/A
V
~
~
+
-
Ground
Figure 54 – PNP Command Input Connection Using External Power
EXTERNAL TRIGGER/ENCODER
DS8100A
A/B
Vext
B/A
V
+ 5V
~
~
+
-
Ground
Figure 55 - NPN Command Input Connection Using External Power
NOTE
Terminal pins I34B are common to both inputs 3 and 4 and therefore these
inputs cannot be driven by opposite polarity devices.
INPUT 3 - 4 CONNECTIONS USING DS8100A POWER
EXTERNAL DEVICE
DS8100A
I3A
Ground
V
+ 5V
~
~
+
-
EXTERNAL DEVICE
GND
V
I4A
+ 5V
~
~
+
-
I34B
VS
Ground
Figure 56 - I3/I4 NPN Input Command using Scanner Power
CUSTOM CABLE ELECTRICAL CONNECTIONS
45
4
INPUT 3 - 4 CONNECTIONS USING EXTERNAL POWER
EXTERNAL DEVICE
DS8100A
I3A
Vext
Ground
V
+ 5V
~
~
+
-
Ground
V
I4A
+ 5V
~
~
+
-
I34B
Vext
Figure 57 - I3/I4 PNP Input Command using External Power
4.4.1 Code Verifier
If the DS8100A is used as a Code Verifier, the verifier code can be configured in software
through the Genius™ configuration program. However it is also possible to use one of the
inputs to trigger when the scanner should store a code read as the verifier code.
The Code Verifier parameter must be enabled, and the configuration parameters to allow
correct Code Type reading must be saved to the scanner in order to read the verifier code.
When the selected input is activated, the next read code will be stored as the verifier code in
the scanner's non-volatile (Flash) memory.
For more details see the Verifier Parameters in the "6-8 K Software Configuration Parameter
Guide” or Help file.
4.5 OUTPUTS
Three general purpose outputs are available. The electrical features are given below:
Outputs 1 and 2
Maximum Voltage
30 V
Collector Current (pulse)
130 mA Max.
Collector Current (continuous)
40 mA Max.
Saturation Voltage (VCE)
1 V at 10 mA Max.
Maximum Power Dissipation
90 mW at 50°C (Ambient temperature)
DS8100A REFERENCE MANUAL
46
4
Output 3 has different electrical features. It is a bi-directional solid state relay with built-in
current limit protection.
Output 3
Maximum Voltage
± 100 V (Vext only)
Collector Current (pulse)
300 mA Max. at 25°C (Ambient temperature)
240 mA Max. at 50°C (Ambient temperature)
Collector Current (continuous)
200 mA Max. at 25°C (Ambient temperature)
150 mA Max. at 50°C (Ambient temperature)
R on
R off
6 – 15 Ω
> 500 Ω
Off-State Leakage Current
< 1 µA
Maximum Power Dissipation
550 mW at 50°C (Ambient temperature)
Pin
Name
Function
8
O1+
Configurable digital output 1 – positive pin
22
O1-
Configurable digital output 1 – negative pin
11
O2+
Configurable digital output 2 – positive pin
12
O2-
Configurable digital output 2 – negative pin
16
O3A
Configurable digital output 3 – polarity insensitive
17
O3B
Configurable digital output 3 – polarity insensitive
The function of each output can be defined by the user (No Read, Right, Wrong, etc.). Refer to
the Genius™ Help On-Line for further details.
The output signals are fully programmable being determined by the configured
Activation/Deactivation events, Deactivation Timeout or a combination of the two.
By default, Output 1 is associated with the Complete Read event, which activates when all
the selected codes are correctly decoded, and Output 2 is associated with the No Read
event, which activates when the code signaled by the external trigger/PS is not decoded.
Output 3 can be assigned to the same events and it has the advantage of being polarity
insensitive. By default it is not assigned to any event.
DS8100A
USER INTERFACE
Vext 30 Vdc max
+
-
Figure 58 – Output 1 and Output 2 Interface
When the load is powered by an external power supply, the voltage must be less than 30 V.
CUSTOM CABLE ELECTRICAL CONNECTIONS
47
4
DS8100A
USER INTERFACE
Vext 100 Vdc max
A/B
B/A
Figure 59 – Output 3 Interface
The command signals are filtered and generate a delay of about 50 µs for Output 1 and 2
and 1 ms for Output 3.
4.6 USER INTERFACE
How To Build A Simple Interface Test Cable:
The following wiring diagram shows a simple test cable including power, external
(push-button) trigger and PC RS232 COM port connections.
26-pin D-sub female
23
20
GND
RXAUX
TXAUX
21
DS8100A
25
13
GND
VS
9-pin D-sub female
GND
TX
RX
PC
2
3
5
18
9
EXT TRIG A
VS
Power Supply
VS (20 – 30 VDC)
Power GND
Trigger
EXT TRIG B
19
Test Cable for DS8100A
DS8100A REFERENCE MANUAL
48
5
5 LONWORKS CONNECTIONS
A1
A2
1
15
scanner side
external view
A1
A2
1
15
OUTPUT (female)
INPUT (male)
Figure 60 - Lonworks INPUT/OUTPUT Connectors
The following pinout is valid for the INPUT connector as well as for the OUTPUT connector.
Lonworks INPUT/OUTPUT 17-pin Connector Pinout
Pin
Name
Function
A1
GND
supply voltage (negative pin)
A2
VS
supply voltage 20 to 30 vdc (positive pin)
1
CHASSIS
Cable shield A – internally connected by capacitor to chassis
2
n.c.
Not connected
3
CHASSIS
Cable shield B – internally connected by capacitor to chassis
4
n.c.
Not connected
5
n.c.
Not connected
6
n.c.
Not connected
7
VS_I/O
Supply voltage of I/O circuit
8
Lon A+
Lonworks a line (positive pin)
9
Lon A-
Lonworks a line (negative pin)
10
Lon B+
Lonworks b line (positive pin)
11
Lon B-
Lonworks b line (negative pin)
12
SYS_I/O
System signal
13
SYS_ENC_I/O
System signal
14
Reserved
Internally connected
15
Ref_I/O
Reference voltage of I/O circuit
5.1 NETWORK TERMINATION
When building a Lonworks system the network must be properly terminated by positioning
the BTK-8102 Lonworks terminator in the DS8100A master reader and the BTK-8100
Lonworks bus return in the last DS8100A slave reader.
The BTK-8100 bus return provides a connector to be inserted in the Lonworks 17-pin female
connector of the last slave reader in the network; while the BTK-8102 Lonworks terminator
provides a different connector to be inserted in the Lonworks 17-pin male connector of the
master reader:
Figure 61 - BTK-8102 and BTK-8100
Two cables are also provided as accessories to terminate and power the network: CAB-8605
and CAB-8305.
CAB-8605 is a power and Lonworks termination cable to be used for connecting the
DS8100A master to an external power unit within the network; while CAB-8305 is a power
and bus return cable to be used for connecting the last DS8100A slave to an external power
unit.
Figure 62 – CAB-8605 and CAB-8305
DS8100A Last Slave
Network
BTK-8102
DS8100A Master
BTK-8100
CAB-81xx
CAB-81xx
CAB-8605
CAB-8305
DS8100A Master
DS8100A Last Slave
Network
Power Unit
DS8100A REFERENCE MANUAL
50
5
5.2 LONWORKS INTERFACE
The Lonworks network is used for both input and output connection to build a multi-sided or
omni-station system connecting several readers.
The DS8100A master usually employs the 17-pin female connector for output connection to
the first slave, while the 17-pin male connector is terminated by inserting the BTK-8102
terminator (see Figure 61 for details).
Both connectors are always employed when connecting together the slave readers. In
particular, the 17-pin female connector is used for output connection and the male one for
input connection. The female connector in the last slave reader is terminated by the
BTK-8100 bus return to close the system network.
The following diagram represents the connection between a DS8100A working as master
and a DS8100A working as a slave reader.
The cable shields for LON A/B are connected to pin1 and pin 3 - CHASSIS.
Master
9
Slave
15
8
13
12
15
13
12
VS_I/O
REF_I/O
A1
1
A2
A1
A2
LON A+
LON A-
VS
GND
AWG 13
AWG 13
= male connector
= female connector
9
8
11
10
LON B+
LON B-
11
10
1
3
3
CHASSIS
CHASSIS
CHASSIS
CHASSIS
Figure 63 – DS8100A Master/Slave Lonworks Connection
The following diagrams represent different network terminations using either the BTK-8102
Lonworks terminator or the BTK-8100 bus return. In Figure 65 the BTK-8102 terminator is
indicated by the element, while the figure below shows its electrical circuit in details:
Figure 64 – BTK-8102 Electrical Circuit
The diagram below represents the termination of the double Lonworks line of a DS8100A
working as master by means of the BTK-8102.
Master
BTK-8102
= male connector
= female connector
9
7
8
A2
7
A2
A1
9
8
A1
LON A+
LON A-
VS
VS_I/O
GND
T
REF_I/O
11
10
11
10
LON B+
LON B-
T
15
15
Figure 65 – DS8100A Master Termination
The diagram below represents the Lonworks bus return of a DS8100A working as slave by
means of the BTK-8100.
Last Slave
BTK-8100
= male connector
= female connector
9
8
1
LON A+
LON A-
9
8
11
10
LON B+
LON B-
11
10
1
3
3
Shields
Figure 66 – DS8100A Lonworks Bus Return
DS8100A REFERENCE MANUAL
52
6
6 FIELDBUS CONNECTIONS
6.1 ETHERNET INTERFACE
This connector is only available for DS8100A Ethernet models and allows the Ethernet
connection between the host and the reader.
Figure 67 – DS8100A M12 4-pin D-Coded Female Ethernet Connector
This interface and the connector pinout (see the following table) are IEEE 802.3 10 BaseT
and IEEE 802.3u 100 Base Tx compliant.
M12 4-pin D-coded Female Pinout
Pin
Name
Function
1
TX +
Transmitted data (+)
2
RX +
Received data (+)
3
TX -
Transmitted data (-)
4
RX -
Received data (-)
In order to meet EMC requirements use Ethernet shielded cable.
The Ethernet interface can be used for TCP/IP communication with a remote or local host
computer by connecting the scanner to either a LAN or directly to a host PC. There is no
need to use a crossover adapter since the scanner incorporates an auto-cross function.
The following is an example of a connection to a LAN using a CAB-ETH-M0x straight
through cable:
DS8100A
3
4
2
1
TX-
RX+
TX+
RX-
LAN
4
2
6
3
1
5
7
8
TX-
RX+
TX+
RX-
M12
D-coded
RJ45
Figure 68 – Straight Through Cable
For further details refer to the “Ethernet Service Guide” document provided as reference
documentation.
3
4
1
2
6.2 ETHERNET INTERFACE (OLDER MODELS)
The RJ Industrial modular connector is only available for older DS8100A Ethernet models
and allows the Ethernet connection between the host and the reader.
Figure 69 – DS8100A Harting RJ Industrial® Female Connector
NOTE
For this Ethernet connection, always use the Harting RJ Industrial® Push
Pull Ethernet connector (included in the package). This connector assures a
robust connection and full IP rated protection.
Figure 70 – Harting RJ Industrial® Push Pull Male Connector
This interface and the connector pinout (see the following table) are IEEE 802.3 10 BaseT
and IEEE 802.3u 100 Base Tx compliant.
RJ45 Modular Jack Pinout
Pin
Name
Function
1
TX +
Transmitted data (+)
2
TX -
Transmitted data (-)
3
RX +
Received data (+)
6
RX -
Received data (-)
4, 5, 7, 8
N.C.
Not connected
In order to meet EMC requirements:
use Ethernet shielded cable
connect the Ethernet interface cable shield to the plant earth ground
NOTE
A ferrite (type Stewart 28A2029-0A0) must be applied on the scanner side
of the Ethernet cable to reduce electrical noise. The cable shield must also
be connected to the chassis of both connectors.
DS8100A REFERENCE MANUAL
54
6
The Ethernet interface can be used for TCP/IP communication with a remote or local host
computer by connecting the scanner to a LAN. It can also be connected directly to a host PC.
The following is an example of a connection to a LAN through a Hub using a straight through
cable:
DS8100A
5
HUB / SWITCH
3
4
2
1
6
5
3
4
2
1
6
7
8
7
8
RX+
TX-
TX+
RX-
n. c.
n. c.
n. c.
n. c.
n. c. = not connected
Figure 71 – Straight Through Cable
The following is an example of direct connection to a PC using an inverted cable:
DS8100A
5
HOST PC
3
4
2
1
6
5
1
4
6
3
2
7
8
7
8
RX+
TX-
TX+
RX-
n. c.
n. c.
n. c.
n. c.
n. c. = not connected
Figure 72 – Inverted Cable
For further details refer to the “Ethernet Service Guide” document provided as reference
documentation.
7 TYPICAL LAYOUTS
DS8100A scanners are mainly designed to work together on a high performance Lonworks
sub-network to create multi-sided and omnidirectional reading stations that can interface with
Serial or Fieldbus Host networks. This chapter covers the most common Lonworks layouts.
DS8100A scanners can however, be connected in a variety of layouts depending on the
number of scanners used and the required complexity of the reading station. Layouts range
from single Stand Alone to complex alternative networks when Lonworks is not available for
all readers (mixed reader networks). For alternative layouts see appendix A.
Several power supplies are available to power the reading stations.
Photoelectric sensors used as code presence sensors and optical encoders to signal
conveyor speed are also available accessories.
The following typical layouts refer to the system hardware configurations, but they also
require the correct setup of the software configuration parameters (see par. 8.2 for details).
The accessories and cables indicated in the following figures are Datalogic products. We
suggest their use to guarantee the correct system functioning.
7.1 LOCAL LONWORKS NETWORK
A local Lonworks network allows logically connecting a DS8100A master reader with up to 31
DS8100A slaves. Actually, the maximum number of readers to be employed in the network
depends on the system operating conditions, that is adopted operating mode and amount of
data stream.
When creating your network, always keep in mind the following guidelines:
the Lonworks network logically supports a maximum number of 32 devices (master +
slaves);
it is recommended to adhere to the 8-in-16 rule (not more than 8 devices in any 16 meter
bus segment (branch);
for DS8100A scanners the total bus length may extend up to 65 m (213 ft);
the maximum number of DS8100A readers supported also depends on the type of power
propagation adopted by the system (see the specific power supply installation manual for
details).
Typically the layouts can be divided into Synchronized (single P.S.) or Multidata (multi P.S.)
networks. They can be small (up to 10 scanners) or large (more than 10 scanners).
Contact Datalogic Automation S.r.l., if your network requires a higher number of readers or in
case the application throughput is very high.
For further information on Lonworks network cabling and connections see the “LonWorks®
TPT Twisted Pair Transceiver Module User’s Guide”, available from the website:
www.echelon.com.
DS8100A REFERENCE MANUAL
56
7
CAUTION
For DS8100A Lonworks Network layouts, power is always propagated
through the 17-pin scanner connectors. A specific jumper setting is required
in CBXs to pass scanner power to the presence sensor, encoder, etc.
7.1.1 Small Synchronized Network
When building a small local Lonworks network (less than 10 scanners), the DS8100A master
reader must be connected to a local host computer or a CBX connection box by means of a
cable connected to the 26-pin D-sub male connector.
The master reader connects to the first slave reader of the system through the local
Lonworks 17-pin female connector. The local Lonworks 17-pin male connector must be
properly terminated by inserting the BTK-8102 Lonworks terminator or be powered by the
CAB-86xx cable.
The slave readers are connected together through the local Lonworks connectors. Only the
17-pin female connector of the last slave reader must be terminated by the BTK-8100 bus
return or be powered by the CAB-83xx cable.
The presence sensor is connected and powered through the CBX by the scanner and is
unique to the system. There is only a single reading phase and a single message from the
master reader to the Local Host. The On-Line operating mode is used for this layout.
*
P.S. (Presence Sensor) connected to Input 1 (External Trigger/PS) input.
** CBX100 jumper set to accept scanner power.
Figure 73 – Small Synchronized Network with 2 Readers
PWR-120
Local Host
CBX100**
Master
Slave 1
CAB-F0x
CAB-81xx
P.S.*
BTK-8102
CAB-83xx
The following image shows a system consisting of five readers where the external signals
(trigger, encoder, serial to host, etc.) are connected to the master through the CBX100.
The system is powered by the PWR-240 where:
the master is connected through CAB-86xx, which also provides bus termination
the last slave is connected through CAB-83xx, which also provides bus return.
the master and all slaves are connected together through the CAB-81xx cables
*
P.S. (Presence Sensor) connected to Input 1 (External Trigger/PS) input.
** CBX100 jumper set to accept scanner power.
*** Encoder connected to Input 2 (Encoder) input.
Figure 74 – Small Synchronized Network with more than 2 Readers and Single Power Unit
CBX100**
Local Host
Master
Slave 1
Slave 2
Slave 3
PWR-240
P.S.*
CAB-81xx
CAB-F0x
CAB-81xx
CAB-81xx
Slave 4
CAB-86xx
CAB-81xx
CAB-83xx
Encoder***
DS8100A REFERENCE MANUAL
58
7
7.1.2 Large Synchronized Network
When building a large local Lonworks network (more than 10 scanners), an SC6000
Controller must be used together with a PWO power supply/junction box unit. In this case the
SC6000 unit acts as the system master and is connected to the host through one of its
interfaces.
All scanners act as slaves and are connected to the SC6000 through the PWO power
supply/junction box. For DS8100A scanners, 4 branch connectors provide Lonworks
communications between the scanners and the SC6000 unit. The last scanner on the line
requires a Termination connector as well as any unused branches in the PWO unit.
The allowed maximum bus length is 65 m.
External devices such as a presence sensor and an encoder are all connected to the PWO.
Figure 75 – Large Synchronized Network with DX8200A and DS8100A Scanners
Extended I/O
Host
HUB
ETHERNET
SC6000
AUX
CAB-SC6003
CAB-SC6013
Power/Net
VAC INPUT
CAB-SC6103
Cable
PWO
LONWORKS
ENCODER
PS
PS Aux
CAB-81xx
CAB-81xx
CAB-81xx
CAB-81xx
CAB-81xx
BTK-8100
Bus Return
DX8200A
DS8100A
DX8200A
DX8200A
DS8100A
DX8200A
DS8100A
CAB-81xx
CAB-81xx
BTK-8100
Bus Return
CAB-81xx
DS8100A
B
A
C
E
G
H
F
D
Figure 76 – Example Large Synchronized Network Reading Station
Here are a few helpful hints which can improve station performance and reduce installation
time:
1. Scanner distribution should alternate between odd and even branches so that the
station guarantees 50% reading on all sides. See also Figure 75.
2. For OEK Encoders set the parameter Operating Mode>Encoder Step = 252.
OFF
ON
1 2 3 4 5 6 7 8
3. For Top Front and Top Back scanners (C and D in Figure 76), set the parameter
Reading Parameters>Reading Condition = Skew 45°.
4. For applications having regular shaped packs the default settings are sufficient, but
for Airport applications, irregular shaped packs can cause PS signal glitches resulting
in false "packs too short" or "packs too close" errors.
To correct this, set the following Operating Modes parameters: Minimum Distance
Between Packs = 200 mm, Minimum Pack Length = 200 mm, Window Dimension = 200 mm.
Conveyor
SC6000
A
H
G
C
D
B
E
F
PWO
DS8100A REFERENCE MANUAL
60
7
7.1.3 Redundant System
For large local Lonworks networks, a redundant system can per configured in which two
SC6000 Controllers are used together with their respective PWO power supply/junction box
units. The scanners are distributed equally between the PWO units. In this case one of the
SC6000 Controllers is dedicated as the working or active unit while the other functions as a
dedicated protecting or backup unit.
Figure 77 - Redundant Reading Station Layout with DX8200A and DS8100A Scanners
AUX
CAB-SC6103
Extended I/O
ETHERNET
SC6000
CAB-SC6003
CAB-SC6013
Power/Net
VAC INPUT
PWO
LONWORKS
ENCODER
PS
PS Aux
CAB-81xx
CAB-81xx
BTK-8100
CAB-81xx
CAB-81xx
CAB-81xx
Extended I/O
ETHERNET
SC6000
CAB-SC6003
CAB-SC6013
Power/Net
VAC INPUT
PWO
CAB-PWO 03
Redundancy
CAB-81xx
CAB-81xx
CAB-81xx
BTK-8100
DX8200A
DS8100A
DX8200A
DS8100A
ENCODER
PS
PS Aux
LONWORKS
Working
Controller
Protecting
Controller
to Host
to Host
DX8200A
DS8100A
DX8200A
DS8100A
A
H
G
C
D
B
E
F
Figure 78 – Example Redundant Reading Station
Conveyor
SC6000
Working
A
H
G
C
D
B
E
F
PWO
SC6000
Protecting
PWO
DS8100A REFERENCE MANUAL
62
7
7.1.4 Multidata Network
In this layout, one master and up to 7 DS8100A slave readers have their own P.S. and
therefore multiple reading phases. Each P.S. is connected through a CBX100, which in turn
is connected to its relative scanner through a CAB-F0x cable.
The master sends all the individual messages collected from the Lonworks interface as well
as its own to the Local Host through its CBX100.
The following image shows a system consisting of four readers, which are all connected
together using CAB-81xx cables and the system is powered by a PWR-240 power supply.
*
P.S. (Presence Sensor) connected to Input 1 (External Trigger/PS) input.
** all CBX100s have jumper set to accept scanner power
Figure 79 – Multidata Network
P.S.*
P.S.*
P.S.*
P.S.*
Slave 1
Master
Slave 2
Slave 3
PWR-240
CAB-81xx
CAB-F0x
Local Host
CBX100**
CBX100**
CAB-81xx
CAB-81xx
CAB-83xx
BTK-8102
7.1.5 Fieldbus Networks
The Fieldbus model (Ethernet) offers connectivity without any converter or adapter needed.
The DS8100A Lonworks master communicates as a Fieldbus slave to a remote host (i.e.
remote PC connected via Internet) by means of a cable connected to the Fieldbus (Ethernet)
connector provided. It can be activated by a signal generated by the remote Host or by a
physical presence sensor.
The external signals (trigger, encoder) are connected to the master through the CBX100.
The system is powered by the PWR-240 where:
the Lonworks master is connected through CAB-86xx, which also provides bus
termination
the last Lonworks slave is connected through CAB-83xx, which also provides bus return.
the Lonworks master and all Lonworks slaves are connected together through the CAB-
81xx cables
The same network layouts are available as for the DS8100A Standard model.
*
P.S. (Presence Sensor) connected to Input 1 (External Trigger/PS) input.
**
CBX100 jumper set to accept scanner power.
***
Encoder connected to Input 2 (Encoder) input.
Figure 80 – Fieldbus Small Synchronized Network
Remote Host
Fieldbus
Network
CBX100**
Master
Slave 1
Slave 2
Slave 3
PWR-240
P.S.*
CAB-81xx
CAB-F0x
CAB-81xx
CAB-81xx
Slave 4
CAB-86xx
CAB-81xx
CAB-83xx
Encoder***
DS8100A REFERENCE MANUAL
64
7
NOTE
To interface DS8100A scanners to other Host types (Fieldbus and non-
Fieldbus), use the CBX800 Gateway with Host Interface Modules.
*
P.S. (Presence Sensor) connected to Input 1 (External Trigger/PS) input.
**
CBX800 jumper set to accept scanner power.
***
Encoder connected to Input 2 (Encoder) input.
Figure 81 – Fieldbus Small Synchronized Network
The following Host Interface Module accessories are available for the CBX800 Gateway:
Name
Description
Part Number
BM200/210
Ethernet TCP/IP Module STD/IP65
93ACC1851, 93ACC1852
BM300/310
Profibus Module STD/IP65
93ACC1810, 93ACC1811
BM400
DeviceNet Module IP65
93ACC1814
BM500/510/520
Ethernet/IP Module STD/IP65/IP54
93ACC1812, 93ACC1813,
93ACC1840
BM600
CANopen Module STD
93ACC1815
BM700/710
Profinet Module STD/IP65
93ACC1816, 93ACC1886
BM1100
CC-Link Module STD
93ACC1845
BM1200/1210
Modbus TCP STD/IP65
93ACC1848, 93ACC1849
Remote Host
Fieldbus
Network
CBX800**
with Host Interface Module
Master
Slave 1
Slave 2
Slave 3
PWR-240
P.S.*
CAB-81xx
CAB-F0x
CAB-81xx
CAB-81xx
Slave 4
CAB-86xx
CAB-81xx
CAB-83xx
Encoder***
8 SOFTWARE CONFIGURATION
8.1 GENIUS™ INSTALLATION
Genius™ is a Datalogic scanner configuration tool providing several important advantages:
Wizard approach for new users;
Multi-language version;
Defined configuration directly stored in the reader;
Communication protocol independent from the physical interface allowing the reader to
be considered as a remote object to be configured and monitored.
To install Genius™, proceed as follows:
1) Turn on the PC that will be used for configuration, running either Windows 98, 2000/NT, XP,
Vista or 7;
2) Insert the Genius™ CD-ROM;
3) Wait for the CD to autorun and follow the installation procedure.
8.2 GUIDE TO RAPID CONFIGURATION
8.2.1 Wizard for Quick Reader Setup
After installing the Genius™ software program (see above), and running it, the following
window appears asking the user to choose the desired configuration level:
Figure 82 - Genius™ Wizard Opening Window
The Wizard option is advised for new users, since it provides a step-by-step scanner
configuration procedure. The parameters to be defined are the following:
-
Barcode selection and definition;
-
Operating mode selection and definition (see sub-paragraphs for further details);
-
Digital Inputs/Outputs configuration;
-
Hardware interface selection;
-
Output data format configuration.
DS8100A REFERENCE MANUAL
66
8
After defining the parameter values the following window appears allowing to complete the
reader configuration as follows:
-
Saving the configuration to disk;
-
Switching to Advanced mode;
-
Sending the configuration to the scanner.
Figure 83 - Genius™ Wizard Closing Window
Test Operating Mode
NOTE
This operating mode is not available when DS8100A works as slave.
Figure 84 - Test Mode Selection
This operating mode causes the reader to be continuously activated allowing to verify its
reading features and its reading position with respect to the barcode. For this reason, it is
particularly advised during the installation phase of the reader.
After 100 scans, the values relative to an internal counter and the decoded code are
displayed and transmitted on the serial interface. The counter reports the percentage of good
reads of the label.
On Line Operating Mode
Figure 85 - On Line Mode Selection
This operating mode causes the reader to be connected to an external Presence Sensor
using I1A and I1B (External Trigger/PS) inputs.
During the active phase of the presence sensor, the DS8100A reader tries to acquire and
correctly decode the code.
In case the decoding phase is successful, the barcode characters are transmitted on the
serial interface. Otherwise, a no read message is sent.
Automatic Operating Mode
Figure 86 - Automatic Mode Selection
This operating mode does not require the connection to an external Presence Sensor.
When working in this mode the reader is continuously scanning. The reading phase is
activated each time a barcode enters the reading zone. The reader stops reading after an N
number of scans without a code. Barcode characters are transmitted on the serial interface.
In case of a failed reading phase no message is sent to the host computer.
DS8100A REFERENCE MANUAL
68
8
8.2.2 Genius™ Network Setup Through Master
The Network Setup allows configuring your Local Lonworks Network through the Master
using Genius™.
Three different procedures are available to define the number of network slave scanners,
their label and address according to two main conditions:
Condition
Available Procedure
Feature
Unknown Slave Addresses
Net-Autoset
automatically assigns random addresses to
slave or Stand Alone scanners.
Known Slave Addresses
Network Wizard
customizes the network (slave label and
address definition and physical identification
of a specific slave within network), updates
configuration to a file and makes it ready to
be sent to the Master.
Express Network Setup
automatically performs all the operations of
the Network Wizard apart from the physical
identification of a specific slave scanner.
NOTE
The Network Setup procedure as described requires Genius™ software
version 1.06 or later. In addition, the Net-Autoset procedure requires
scanner software version 6.40 or later.
1. The first operation to perform is the configuration of your scanner as "Master" from the
Local Device Network Settings item in the Device Menu, see figure below:
Figure 87 – Local Device Network Settings
The following dialog box appears asking whether to send the configuration to the Local
Device or not:
2. Click the "Yes" button, then click on the
icon available on the Toolbar to make the
“Devices” area appear next to the Parameter Explorer window. By repeatedly clicking the
icon this area will be displayed or hidden.
Figure 88 – Cluster Configuration
Each scanner of the cluster is indicated by the following graphical objects:
check box allowing to select/deselect a specific scanner to perform the desired
operations (i.e. program downloading);
icon representing the scanner status;
a label reporting information transmitted by the scanner when connected (the scanner
address, generated errors, scanner description).
DS8100A REFERENCE MANUAL
70
8
3. Then, proceed with the network setup by using one of the icons available on the Tool
Bar according to the procedure to follow:
=
Net-Autoset procedure
=
Network Wizard procedure
=
Express Network Setup procedure
Net-Autoset
This procedure is to be used when all scanner addresses and labels are unknown (typically
when configuring the network for the first time or whenever a network reconfiguration is
required).
By clicking the
icon or selecting the "Net_Autoset" option from the right-click menu, the
Net-Autoset procedure is started allowing automatic assignment of random addresses to all
slave or Stand Alone scanners connected within the network.
Once the procedure has been completed, it is possible to:
define customized addresses and labels through the Network Wizard;
display the scanner default labels through the Express Network Setup.
Express Network Setup
Before performing this procedure, a Lonworks address must be assigned to each slave
scanner. The most practical method is through the Net-Autoset procedure. See par. 8.2.3 for
alternative address assignment methods.
Once all addresses have been assigned, the Express Network Setup is to be used when all
scanner addresses and labels do not need to be modified.
By clicking on the
icon or by choosing the related option from the right-click menu, the
procedure is started which automatically performs the following operations:
-
opening the wizard;
-
polling the network to discover connected scanners;
-
transferring all scanners found to the "Requested Devices" area of the wizard where
your network customization is defined;
-
saving the new network configuration;
Once the procedure has been completed, a dialog box will appear asking whether to send
the configuration to the Master. Choose the “Yes” option to start this procedure.
Before performing this procedure, a Lonworks address must be assigned to each slave
scanner. The most practical method is through the Net-Autoset procedure. See par. 8.2.3 for
alternative address assignment methods.
Once all addresses have been assigned, the Network Wizard is to be used when one or
more scanner addresses and labels need to be modified.
1. Click on the
button to open the Network Wizard dialog box:
a. if the slave scanners have already been configured and wired to the network, click on
the Autodetect button to start a polling procedure of the current network. All slave
scanners found will be represented in the “Current Devices” area. Then, select the
desired slave scanner from the “Current Devices” area and click on the
icon (or
drag and drop) to transfer it to the “Requested Devices” area where your network
customization is defined. The following dialog box will appear allowing (if necessary)
to change the slave address ("Available Device" field) and label ("Description" field):
b. if the slave scanners have not been configured and wired to the network, click on the
icon to add a new device defining its address and model. The added slave
scanner will be then displayed in the “Requested Devices” area. This option in any
case requires that all slave scanners have their address set before the network can
function.
DS8100A REFERENCE MANUAL
72
8
2. If desired, select a slave scanner within the "Current Devices" area and click on the
icon (or select the "Show Device" option from the right-click menu) to make the
dialog box appear as follows:
The "Show Device" option is particularly useful after the Net-Autoset procedure or
whenever it is necessary to know which address is assigned to a specific slave
scanner. Indeed, it activates the following signals which physically indicate the
scanner corresponding to the one selected, in particular:
in Network Wizard the icon corresponding to the selected slave scanner starts
blinking red;
in the Physical Network all slave scanner lasers turn off except the one of the
selected scanner which turns on.
3. If desired, select the transferred/added slave scanner within the “Requested Devices”
area and click on the
icon to customize the scanner label and address.
4. Once your network has been customized, close the network wizard. Before closure,
the program will show a dialog box asking whether to send the new configuration to
the Master. Choose the “Yes” option to start this procedure.
8.2.3 Alternative Slave Address Assignment
As alternatives to Network Setup through the Master, each Slave scanner can be assigned
an address through the following methods:
address setting through the Local Device Network Settings item in the Device Menu
with the slave scanner connected to Genius™
manual address setting through slave scanner keyboard (see par. 1.6.1 for details)
8.3 ADVANCED GENIUS™ CONFIGURATION
The ADVANCED selection available when starting the Genius™ program is addressed to
expert users being able to complete a detailed scanner configuration. By choosing this option
it is possible either to start a new scanner configuration or to open and modify an old one.
The desired parameters can be defined in the following window, similar to the MS Explorer:
Figure 89 - Genius™ Parameter Explorer Window
The procedure for setting the scanner parameters is supported by a Help On-Line, which is
displayed in an HTML browser. It can be selected from the Configuration Help option
available in the Help menu. In addition, a context-sensitive help can be enabled by pressing
the key after selecting the desired parameter.
DS8100A REFERENCE MANUAL
74
8
8.3.1 Genius™ Shortcuts for Network Configuration
Once the Network Setup is structured in Genius and the Master is configured, there are a
few shortcuts that Genius offers to quickly configure the slaves.
By right-clicking on a device in the "Devices" area a shortcut menu appears which allows you
to:
Copy the device configuration
Paste a previously copied configuration
Copy the Master device configuration parameters to all Slaves (only common
parameters relative to Slave functioning, i.e. Code Definition, Diagnostics, etc.)
Show Device to physically locate a scanner in the station
These shortcuts are made only in Genius™ and require sending the configurations to
the scanners to be saved.
It is possible to Paste, Send or Load configurations simultaneously1 to a selected number of
devices by clicking the relative device check box and executing the desired command.
These same functions2 can be selected from the Edit menu as well.
1 Not for Master and Slaves simultaneously.
2 Not for Master and Slaves simultaneously. If using the "Select All Devices" menu item, uncheck either the Master or all slaves.
DS8100A REFERENCE MANUAL
76
8
8.4 PARAMETER DEFAULT VALUES
The following table contains the list of the factory default settings for the DS8100A.
Genius™ also allows checking the parameter default values by selecting the "Compare
parameters" option available in the Tools menu and comparing the current scanner
configuration to the default one.
Parameter
Default Setting
Code Definition
Code Combination
Single Label
No Read Message
Global No Read Message
No Read String
Multi Filters
Disabled (unchecked)
Code Label Settings #1
Code Symbology
Interleaved 2 of 5
Label Length
8
Min Code Position
0
Max Code Position
255
Check Digit
Disabled (unchecked)
Decoding Safety
1
Decoding Severity
3
Match String Rule
Match
Pattern Match String
Empty
Match Direction Rule
Disable
Code Label Settings #2
Code Symbology
Code 39
Label Length
Variable
Minimum Label Length
1
Maximum Label Length
60
Min Code Position
0
Max Code Position
255
Check Digit
Disabled (unchecked)
Decoding Safety
1
Match String Rule
Match
Decoding Severity
3
Pattern Match String
Empty
Match Direction Rule
Disable
Operating Mode
Operating Mode Selection
On Line
On Line Options
On Line 1 Input
Start Input Number
1
Start Input Active Level
Active Closed
Reading Phase Timeout
Disabled (unchecked)
Start Input from Bus
Disabled (unchecked)
Protocol Index
Disabled (unchecked)
Verifier
Disabled (unchecked)
Reading System Layout
Device Assignment
Alone
Modify&Backup Lon Slave Configuration
Disabled (unchecked)
Enable A.S.R.
Disabled (unchecked)
Reading Parameters
Beam Shutter
Disabled
Overflow Start Ratio
5
Overflow Stop Ratio
5
Reading Mode
Reconstruction
Reading Condition
Standard
Reconstruction Parameters
Enabled Stacked Code
Disabled (unchecked)
Extended
Min Match
0
Position Tolerance
50
Duration Tolerance
50
Min Start/Stop Number
2
Inter Char Gap
8
Addon Start/Stop Overflow Ratio
2
Max distance between EAN/UPC
and Addon (in modules)
20
Scan Line Amplitude
Amplitude Settings Enable
Disabled (unchecked)
PackTrack Calibration
Direction
0 (Forward)
PS Offset
0
Data Communication Settings
Host Application Protocol Type
Standard
Data Format
Header Tx Start
With Data
Termination After No Read Message
Enabled (checked)
Message Tx Selection
On Decoding
Format Type
Standard
Max. Tx Delay After Phase Off
Disabled
Code Identifier
Disabled
Standard Parameters
Header String
Code Position Tx
Disabled (unchecked)
Code Direction Identifier Enable
Disabled (unchecked)
Termination String
Data Packet Separators
Code Field Length Setting
Variable Length
Main Serial Port
Main Serial Interface Dedicated to ID-NET
Disabled (unchecked)
Data Tx
Enabled (checked)
Heartbeat
Disable
DS8100A REFERENCE MANUAL
78
8
Parameter
Default Setting
Main Serial Port Parameters
Main Port Communication Mode
Standard
Main Port Electrical Interface
RS232
Handshake
None
Baud Rate
9600
Parity
None
Data Bits
8
Stop Bits
1
Auxiliary Serial Port
Search for CBX BM100 at Device Startup
Enabled (checked)
Data Tx
Enabled (checked)
Heartbeat
Disable
Pass Through
Disabled (unchecked)
Auxiliary Serial Port Parameters
Baud Rate
115200
Parity
None
Data Bits
8
Stop Bits
1
Digital I/O Setting
Digital Input Lines Setting
Debouncing For Input 1, 3 and 4
5ms
Debouncing For Input 2
500 µs
Input 1 Active Level Overridden by Op. Mode Active Closed
Input 2 Active Level Overridden by Op. Mode Active Closed
Input 3 Active Level Overridden by Op. Mode Active Closed
Input 4 Active Level Overridden by Op. Mode Active Closed
Output 1
Line State
Normally Open
Activation Event
Complete Read
Alternative Activation Event
Wrong
Deactivation Event
Timeout
Alternative Deactivation Event
None
Activate on any Diagnostic Error
Disabled (unchecked)
Deactivate when all Diagnostic Errors
Recovered
Disabled (unchecked)
Deactivation Timeout (ms)
50
Output 2
Line State
Normally Open
Activation Event
No Read
Alternative Activation Event
Partial Read
Deactivation Event
Timeout
Alternative Deactivation Event
None
Activate on any Diagnostic Error
Disabled (unchecked)
Deactivate when all Diagnostic Errors
Recovered
Disabled (unchecked)
Deactivation Timeout (ms)
50
Alternative Activation Event
None
Deactivation Event
None
Alternative Deactivation Event
None
Activate on any Diagnostic Error
Disabled (unchecked)
Deactivate when all Diagnostic Errors
Recovered
Disabled (unchecked)
Diagnostics
PackTrack Debug Message Tx
Disabled (unchecked)
Enable
Enabled (checked)
Conveyor Info
Not Available
Refresh Time
2 sec
Local Network Failure
Enabled (checked)
No Scan
Enabled (checked)
No Sync
Enabled (checked)
No Phase Timeout
Disable
DIGITIZER: Motor Warning
Enabled (checked)
DIGITIZER: Motor Failure
Enabled (checked)
DIGITIZER: Motor Life End
Enabled (checked)
DIGITIZER: Laser Failure
Enabled (checked)
DIGITIZER: Laser Life End
Enabled (checked)
Actions
Tx Mode
On Timeout
Tx Refresh
2 sec
Aux
Disabled (unchecked)
Main
Disabled (unchecked)
Format
Header String
Terminator String
Error Message Type
Numeric
Statistics
Enable
Enabled (checked)
Separator
Time (hh mm)
Disabled (unchecked)
Phase Counter
Disabled (unchecked)
Good Read Counter
Disabled (unchecked)
Partial Read Counter
Disabled (unchecked)
No Read Counter
Disabled (unchecked)
Multiple Read Counter
Disabled (unchecked)
Energy Saving
Energy Saving Configuration
Disabled (unchecked)
DS8100A REFERENCE MANUAL
80
8
Parameter
Default Setting
User Information Section
End User Name
Empty
Device Name
Empty
Line Name
Empty
9 READING FEATURES
9.1 ADVANCED CODE RECONSTRUCTION (ACR™ 4)
The traditional way of barcode reading could be called “Linear Reading”. In this case, the
laser beam crosses the barcode symbol from its beginning to its end as shown in the
following figure:
Laser Beam
Figure 90 – Linear Reading
In Advanced Code Reconstruction mode it is no longer necessary for the laser beam to cross
the label from the start to the end. With just a set of partial scans on the label (obtained using
the motion of the label itself), the DS8100A is able to “reconstruct” the barcode. A typical set
of partial scans is shown in the figure below:
Code Direction
Figure 91 – Partial Scans
None of the partial scans contains the whole label. The decoder aligns each partial scan
correctly and combines them in order to obtain the entire code.
The alignment is performed by calculating the time difference from one partial scan to
another using a reference code element.
9.1.1 Tilt Angle for Advanced Code Reconstruction
The most important parameter in Advanced Code Reconstruction is the value of the
maximum tilt angle (
maximum) under which the code reconstruction process is still
possible.
Laser Beam
= tilt angle
0° to max
Figure 92 – Tilt Angle
DS8100A REFERENCE MANUAL
82
9
The
decoder
will
be
able
to
read
the
label
with
a
tilt
angle
between
+ max and - max as shown in the following figure:
Conveyor
Laser Beam
No Read
No Read
- +
0°
OK
OK
OK
OK
OK
No Read
Figure 93 – Reading Zones with Max
The formulas to calculate maximum depend on various parameters such as: label height,
number of scans per second, code motion speed, etc. Minimum label heights at different
conveyor speeds are given in the tables in par. 9.3.1, depending on standard values of 45°
and 30°.
9.2 PACKTRACK™
PackTrack™ is a patented operating mode for Datalogic Omni-Directional Reading Stations
used to read and correctly assign codes read on different packs when placed in the scanner
Reading Area at the same time.
In fact, in the following example, the codes of two or more consecutive packs are found at
the same time in the scanner reading area. Therefore, the condition occurs where, in the
sequence of the two packs, the code of the second pack is read first, just before the code of
the previous pack. A system without PackTrack™ would assign the code of the second pack
to first pack and vice versa, thus causing a gross error in sortation.
Figure 94 – PackTrack™ System Layout
Working in PackTrack™ mode requires an encoder and a presence sensor (or equivalent
signals) to track the moving packs.
For correct functioning, the PackTrack™ operating mode requires a calibration just after the
installation of the scanners. This operation is absolutely necessary to accurately locate
barcodes on a fixed reference system.
PackTrack™ uses a right-handed reference system (right hand with thumb = X axis;
forefinger = Y axis; middle finger = Z axis) where the axis X coincides with the PS line, the Y
axis coincides with the conveyor direction and the Z axis is oriented upwards from the
conveyor (see figure below).
PackTrack™ Reference System
Figure 95 – PackTrack™ Reference System
This coordinate system is absolute for the reading station, i.e. is valid for all the scanners
independently from their position or orientation with respect to the conveyor. For this reason,
after the PackTrack™ calibration (and configuration) has been correctly performed, when a
barcode is under the beam to be read by the scanners, its position is defined by the
coordinates of its central point, independently from which scanner is reading it. This can be
verified using the Test mode in the SPY PackTrack Calibration dialog box (see par. 9.2.2).
Both Auto PackTrack Calibration using the DLAPC tool and Manual PackTrack™ Calibration
using the SPY tool can be performed in Genius™ (refer to the following paragraphs and the
Genius™ Help On-Line for details).
DS8100A REFERENCE MANUAL
84
9
9.2.1 Auto PackTrack™ Calibration for Reading Station Using DLAPC
In a Master /Slave Reading Station working in PackTrack™ or Continuous operating mode,
the entire Reading Station can be automatically calibrated using the DLAPC tool in Genius™.
The following paragraphs detail the Conditions and Limits, Parameters, and Procedure to
follow. This information is also given in the Help On-Line.
Auto PackTrack Conditions and Limits
The Conditions and Limits for Auto PackTrack Calibration are summarized here for
convenience and are also integrated into the following procedure descriptions:
The following scanners are supported by Auto PackTrack Calibration: DS6400 (*see note
below), DX6400 (*see note below), DS8100A, DX8200A.
Before performing the Auto PackTrack Calibration procedure, if a system reset or power
reset is performed, wait for all the scanners to be available (up to 60 sec.) before
proceeding.
Operating Mode of the Master must be either PackTrack or Continuous.
Code 128 codes must be enabled on the Master with Label Length set to variable.
If the system Presence Sensor and Encoder are used, the correct Encoder Step value
must be set on the Master and the Presence Sensor must be connected to the
CBX100/500 Input 1.
If instead the PPA-8000 Photocell Array is used, it must be connected to the CBX100/500
I1 and I2 inputs, the following parameters must be disabled on the Master: Physical
Encoder for PackTrack or Use Encoder for Continuous, and the Encoder, if present,
must be physically disconnected.
DX scanners which are calibrated automatically cannot be automatically replaced by DX
scanners with a previous sw version (earlier than 6.80). You must either update the old
scanner software prior to substitution, or complete the calibration manually, after
installation, by setting the PSOffset and Direction parameters.
NOTE
The autofocus feature of DS6400 and DX6400 scanners makes Auto
PackTrack Calibration difficult, therefore to assure that the procedure can
correctly calibrate these scanners, it is necessary to set a fixed focus value
which allows the scanner to read all the label positions useful for its
calibration.
Auto PackTrack Parameter Descriptions
By means of the software tool DLAPC, it is possible to perform the Auto PackTrack setup
procedure for PackTrack™ and Continuous Operating Mode applications.
Select the "DLAPC" option from the Tools menu or click on the related icon on the Tool Bar
to open the following dialog box:
Once the DLAPC window has been opened, set the following parameters according to the
application requirements:
Sensor Type: whether calibration will be performed using the system Presence Sensor and
Encoder (most cases), or the PPA-8000 Photocell Array.
NOTE
The Auto PackTrack procedure requires using the PPA-8000 Photocell
Array for all systems where either the Presence Sensor or the Encoder are
absent (including Continuous Operating Mode and Cargoscan applications).
If using the Presence Sensor and Encoder, the presence sensor must be connected to the
CBX100/500 I1 input. The Encoder Step parameter must also be set correctly.
If using the PPA-8000 you must set the Photocell distance (165 mm default). The Photocell
Array must be connected to the CBX100/500 I1 and I2 inputs (see the relative installation
manual), and the Encoder, if present, must be disconnected.
Pack Version: the version of the PCT-8000 being used for calibration. This value can be
read from the barcode labels on the PCT-8000. Each label has the value vnnn where v is the
version number.
DS8100A REFERENCE MANUAL
86
9
Calibration Type: XYZ calibration with Absolute X position is forced. The coordinates for the
three axes are calibrated. The X coordinate for all slaves is relative to a precise point
(reference point). This requires that the X Offset be set which will be used to harmonize the
X=0 coordinate of all of the individual slaves.
NOTE
For Oscillating Mirror models the scan line must be parallel to the conveyor
direction and only the Y calibration will be performed, (the X and Z axes will
automatically be set to zero).
Z Offset (if necessary): for packs that are elevated above the conveyor surface (for example
on tilt trays), this parameter sets an offset for the height of a pack so that Z = 0 corresponds
to the bottom of the pack.