Datalogic DX6400 Quick Reference Manual
Text of the manual
QUICK REFERENCE GUIDE
NOTE
This manual illustrates Local Lonworks network applications. For other types of installations,
such as ID-NET™, Pass-Through, Multiplexer Layout, etc., refer to the DX6400 Reference
Manual available on the CD. For complete scanner configuration using the Genius™
configuration program refer to the Help On Line.
821001218 (Rev. J)
DX6400 QUICK GUIDE
2
UPDATES AVAILABILITY
UK/US
The latest drivers and documentation updates for this product are available on Internet.
Log on to: www.automation.datalogic.com
I
Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo
prodotto. Collegarsi a: www.automation.datalogic.com
F
Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur
Internet. Cliquez sur : www.automation.datalogic.com
D
Im Internet finden Sie die aktuellsten Versionen der Treiber und Dokumentation von diesem
Produkt. Adresse : www.automation.datalogic.com
E
En Internet están disponibles las versiones actualizadas de los drivers y documentación de
este producto. Dirección Internet : www.automation.datalogic.com
SERVICES AND SUPPORT
Datalogic provides several services as well as technical support through its website. Log on to
www.automation.datalogic.com and click on the links indicated for further information:
PRODUCTS
Search through the links to arrive at your product page which describes specific Info, Features, Applications,
Models, Accessories, and Downloads including the Genius™ utility program, which allows device
configuration using a PC. It provides RS232 and Ethernet interface configuration.
SERVICE
- Overview - Warranty Extensions and Maintenance Agreements
- Sales Network- Listing of Subsidiaries, Repair Centers, Partners
- Helpdesk
- Material Return Authorization
LEGAL NOTICES
© 2003 - 2012 Datalogic Automation S.r.l. ALL RIGHTS RESERVED. Protected to the fullest extent under
U.S. and international laws. Copying, or altering of this document is prohibited without express written consent
from Datalogic Automation S.r.l.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the
U.S.A. and the E.U.
Genius, PackTrack, Step-a-Head, FLASH, ACR, and ID-NET are trademarks of Datalogic Automation
S.r.l. All other brand and product names mentioned herein are for identification purposes only and may be
trademarks or registered trademarks of their respective owners.
Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or
consequential damages resulting from the use of this material.
DX6400 QUICK GUIDE
3
DX6400 GENERAL VIEW
Figure A
Figure B
Standard
Ethernet
Figure C
1
2
2
3
4
5
1
1
3
2
2
4
3
Laser Beam Output Window
1
Laser Safety Label
2
Programming Keypad
1
Phase On LED (Yellow)
3
TX Data LED (Green)
2
Power On LED (Red)
4
LCD Display
5
Lonworks 9-pin Male Connector
1
Lonworks 9-pin Female Connector
2
Serial Interface and I/O 25-pin (26-pin) Male
Connector
3
Ethernet 4-pin Female Connector
4
DX6400 QUICK GUIDE
4
CONNECTIVITY
Examples of the most common system layouts are shown in this section, for additional layouts refer to the
Reference Manual.
Local Lonworks Networks
Small Synchronized Network with 2 Readers
Note: In a mixed 8K and 6K family scanner network, only the 8K family scanner can be Master
*
P.S. (Presence Sensor) connected to Input 1 (External Trigger/PS) input.
**
CBX100 jumper set to accept scanner power.
***
Encoder connected to Input 2 (Encoder) input.
Synchronized Network with DS8100A Master and 6K Family Slaves - Serial Host
CAB-610x
CBX100**
Local Host
Master
Slave 1
Slave 2
Slave 3
PWR-240
P.S.*
CAB-610x
CAB-F0x
CAB-610x
CAB-650x
Slave 4
CAB-63xx
CAB-63xx
I/O, AUX, Encoder***
BTK-8102
BT-6000
PWR-120
Local Host
CBX100**
Master
Slave 1
CAB-Sxx
CAB-610x
P.S.*
BT-6000
I/O, AUX
BT-6000
*
P.S. (Presence Sensor) connected to Input 1 (External Trigger/PS) input.
** CBX100 jumper set to accept scanner power.
CAB-63xx
DX6400 QUICK GUIDE
5
*
P.S. (Presence Sensor) connected to Input 1 (External Trigger/PS) input.
**
CBX100 jumper set to accept scanner power.
***
Encoder connected to Input 2 (Encoder) input.
Synchronized Network with DX6400 Master and 6K Family Slaves - Fieldbus Host
*
Each P.S. (Presence Sensor) connected to Input 1 (External Trigger/PS) input.
Multidata Network
NETWORK TERMINATION
When building a local Lonworks system the network must be properly terminated by positioning a BT-6000
terminator on the DX6400 Standard master reader (BT-6000 female side) and on the last slave reader (BT-6000
male side). For Fieldbus models, (Lonworks master-only), the bus is internally terminated (no BT-6000).
BT-6000 Network Terminator
to Master
9-pin female
to Slave
9-pin male
CAB-610x
CBX100**
Remote Host
Master
Slave 1
Slave 2
Slave 3
PWR-240
P.S.*
CAB-610x
CAB-F0x
CAB-610x
CAB-610x
Slave 4
CAB-63xx
CAB-63xx
I/O, AUX, Encoder***
BT-6000
Fieldbus
CBX100
Local Host
P.S.*
CAB-Sxx
CAB-611x
CAB-611x
CAB-611x
CAB-Sxx
CAB-Sxx
CAB-Sxx
BT-6000
BT-6000
Slave 3
Slave 2
Slave 1
Master
P.S.*
P.S.*
P.S.*
PG6000
PG6000
PG6000
PG6000
DX6400 QUICK GUIDE
6
ELECTRICAL CONNECTIONS
The details of the connector pins are indicated in the following tables:
The table below gives the pinout of the CBX100/CBX500 terminal block connectors. Use this pinout when the
DX6400 reader is connected by means of the CBX100/CBX500:
CBX100/500 Terminal Block Connectors
Power
Vdc
Power Supply Input Voltage +
GND
Power Supply Input Voltage -
Earth
Protection Earth Ground
Inputs
+V
Power Source – Inputs
-V
Power Reference – Inputs
I1A
EXT TRIG/PS A (polarity insensitive) for PS
I1B
EXT TRIG/PS B (polarity insensitive) for PS
I2A
IN 2/ENC A (polarity insensitive) for Encoder
I2B
IN 2/ENC B (polarity insensitive) for Encoder
I3A
IN 3A (polarity insensitive) (only with CBX500)
I4A
IN 4A (polarity insensitive) (only with CBX500)
I34B
IN 3B/IN 4B Reference (polarity insensitive) (only with CBX500)
Outputs
+V
Power Source - Outputs
-V
Power Reference - Outputs
O1+
OUT 1+
O1-
OUT 1-
O2+
OUT 2+
O2-
OUT 2-
O3A
OUT 3A (polarity insensitive) (only with CBX500)
O3B
OUT 3B (polarity insensitive) (only with CBX500)
Auxiliary Interface
TX
Auxiliary Interface TX
RX
Auxiliary Interface RX
SGND
Auxiliary Interface Reference
Shield
Shield
Network Cable Shield
Main Interface
RS232
RS485 Full-Duplex
RS485 Half-Duplex
TX
TX+
RTX+
RTS
TX-
RTX-
RX
*RX+
CTS
*RX-
SGND
SGND
SGND
* Do not leave floating, see Reference Manual for connection details.
CAUTION
Do not connect GND and SGND to different (external) ground references. GND and SGND
are internally connected through filtering circuitry which can be permanently damaged if
subjected to voltage drops over 0.8 Vdc.
DX6400 QUICK GUIDE
7
The DX6400 scanner provides a 25-pin (26-pin for Ethernet models) male D-sub connector for connection to
power supply, Host interface (Main and Aux), and input/output signals.
25-pin / 26-pin D-Sub Connector Pinout
Pin
Name
Function
Chassis - internally connected to GND
1
CHASSIS
Cable shield connected to chassis
20
RXAUX
Receive data of auxiliary RS232 (referred to GND)
21
TXAUX
Transmit data of auxiliary RS232 (referred to GND)
8
OUT 1+
Configurable digital output 1 – positive pin
22
OUT 1-
Configurable digital output 1 – negative pin
11
OUT 2+
Configurable digital output 2 – positive pin
12
OUT 2-
Configurable digital output 2 – negative pin
16
OUT 3A
Configurable digital output 3 – polarity insensitive
17
OUT 3B
Configurable digital output 3 – polarity insensitive
18
EXT_TRIG/PS A External trigger (polarity insensitive) for PS
19
EXT_TRIG/PS B External trigger (polarity insensitive) for PS
6
IN2/ENC A
Input signal 2 (polarity insensitive) for Encoder
10
IN2/ENC B
Input signal 2 (polarity insensitive) for Encoder
14
IN3A
Input signal 3 (polarity insensitive)
15
IN4A
Input signal 4 (polarity insensitive)
24
IN_REF
Common reference of IN3 and IN4 (polarity insensitive)
9, 13
VS
Supply voltage – positive pin
23, 25, 26 GND
Supply voltage – negative pin
14
1
25
13
25-pin male D-sub Connector
10
19
1
18
9
26
26-pin male D-sub Connector
Main Interface
Pin
RS232
RS485 Full-Duplex
RS485 Half-Duplex
2
TX
TX485+
RTX485+
3
RX
* RX485+
4
RTS
TX485-
RTX485-
5
CTS
* RX485-
7
GND_ISO
GND_ISO
GND_ISO
* Do not leave floating, see Reference Manual for connection details.
Two 9-pin connector(s) provide access to the scanner’s local Lonworks network.
The Standard Master/Slave model has two Lonworks connectors used for both input and output connections to
build a multi-sided or omni-station system.
The Fieldbus model (Ethernet) has one Lonworks connector and therefore can be used in a Lonworks network
only as a Master. For this model the Lonworks bus is internally terminated (no BT-6000).
9-pin Lonworks Connector Pinout
Pin
Name
Function
Cable shield internally connected
1
CHASSIS
by capacitor to chassis
9
VS
Supply voltage – positive pin
2
GND
Supply voltage – negative pin
6
VS_I/O
Supply voltage of I/O circuit
3
Ref_I/O
Reference voltage of I/O circuit
4
SYS_ENC_I/O
System signal
5
SYS_I/O
System signal
7
LON A
Lonworks line (polarity insensitive)
8
LON B
Lonworks line (polarity insensitive)
5
1
9
6
Female
1
5
6
9
Male
(Standard model only)
9-pin Local Lonworks Connectors
DX6400 QUICK GUIDE
8
Ethernet Model
M12 D-coded Ethernet Connector
DX6400
3
4
2
1
TX-
RX+
TX+
RX-
LAN
4
2
6
3
1
5
7
8
TX-
RX+
TX+
RX-
M12
D-coded
RJ45
M12 D-coded Female Connector
APPENDIX
TECHNICAL FEATURES
ELECTRICAL FEATURES
Supply Voltage
15 to 30 Vdc
Power Consumption
18 W typical
1.5 to 0.7 A max. (including startup current)
Main
Baud Rate
RS232
RS485 full-duplex
RS485 half-duplex
1200 to 115200
Auxiliary
RS232
1200 to 115200
Other
Common Communication Interfaces
Lonworks
1.25 Mb/s
Model-Dependent Communication
Interfaces
Ethernet
100 Mb/s
Inputs
Ext. Trigger 1, Encoder
2 aux. digital inputs
(optocoupled NPN or PNP)
Outputs
3 software programmable digital outputs
(optocoupled)
OPTICAL FEATURES
Light Receiver
Avalanche photodiode
Wavelength
630 to 680 nm
Safety Class
Class 2 - EN60825-1; Class II - CDRH
Light Source
Up to 2 semiconductor laser diodes
Laser Control
Security system to turn laser off in case of motor slow down
3
4
1
2
DX6400 QUICK GUIDE
9
READING FEATURES
Scan rate
up to 1500 scans/s (750 per leg)
Maximum Resolution
Max. Reading Distance
Max. Reading Width
Max. Depth of Field
(see reading diagrams)
USER INTERFACE
LCD Display
2 lines by 16 characters LCD
Keypad
3 keys
LED Indicators
Power On (red)
Phase On (yellow)
TX Data (green)
SOFTWARE FEATURES
Readable Codes
Interleaved 2/5
Code 39 Standard
Codabar
Code 128
GS1-128 (ex EAN 128)
Code 93 (standard and full ASCII)
EAN/UPC (including Add-on 2 and Add-on 5)
GS1 DataBar (including Limited and Expanded)
Code Selection
Up to 10 codes during one reading phase
Headers and Terminators
Up to 128-bytes headers and 128-bytes terminators
Operating Modes
On Line, Serial On Line, Automatic, Test, PackTrack™, Continuous
Configuration Modes
Genius™ utility program
Parameter Storage
Non-volatile internal FLASH
ENVIRONMENTAL FEATURES
Operating Temperature
0° to +40 °C (+32° to +104 °F)
Storage Temperature
-20° to +70 °C (-4° to +158 °F)
Humidity
90% non condensing
Ambient Light Immunity
10000 lux
Vibration Resistance
EN 60068-2-6
2 hours on each axis
14 mm @ 2 to 10 Hz;
1.5 mm @ 13 to 55 Hz;
2 g @ 70 to 200 Hz
Shock Resistance
EN 60068-2-27
3 shocks on each axis
30 g; 11 ms
Protection Class – EN 60529
IP64
PHYSICAL FEATURES
Mechanical Dimensions
225.9 x 149.8 x 116.8 mm (8.89 x 5.90 x 4.60 in)
Weight
2.1 kg. (4.62 lbs)
MODEL DESCRIPTION
Decoder Model
10 = Master/Slave
12 = Ethernet
DX6400 - 100 - 0XX
DX6400 QUICK GUIDE
10
ACCESSORIES
Name
Description
Part Number
Power Supplies
PG6002
Single unit power supply (US)
93ACC1718
PG6001
Single unit power supply (UK)
93ACC1719
PG6000
Single unit power supply (EU)
93ACC1720
PWR-120
J-box power unit 110/230 VAC 24 V 120 W
93ACC1530
PWR-240
J-box power unit 110/230 VAC 24 V 240 W
93ACC1070
PWR-480A
J-box power unit 110/230 VAC 24 V 480 W
93ACC1850
Cables and Terminators
BT-6000
Bus terminator
93A051299
CAB-6101
9-pin scanner/scanner connection cable 1 m
93A051220
CAB-6102
9-pin scanner/scanner connection cable 2 m
93A051230
CAB-6105
9-pin scanner/scanner connection cable 5 m
93A051240
CAB-6112
9-pin scanner to scanner no power cable 2 m
93A051224
CAB-6115
9-pin scanner to scanner no power cable 5 m
93A051225
CAB-6305
25-pin power cable Fam 6k 5 m
93ACC1768
CAB-6310
25-pin power cable Fam 6k 10 m
93ACC1752
CAB-S01
STD cable to CBX 1 m (25-pin to 25-pin)
93A051351
CAB-S02
STD cable to CBX 2 m (25-pin to 25-pin)
93A051352
CAB-S05
STD cable to CBX 5 m (25-pin to 25-pin)
93A051353
CAB-S10
STD cable to CBX 10 m (25-pin to 25-pin)
93A051354
CAB-F01
6K-8K FBUS cable to CBX 1 m (26-pin to 25-pin)
93A051355
CAB-F02
6K-8K FBUS cable to CBX 2 m (26-pin to 25-pin)
93A051356
CAB-F05
6K-8K FBUS cable to CBX 5 m (26-pin to 25-pin)
93A051357
CAB-6502
Fam 6K-8K cross cable 2.5 m (9-pin to 17-pin)
93A051288
CAB-6505
Fam 6K-8K cross cable 5 m (9-pin to 17-pin)
93A051289
CAB-ETH-M01
M12-IP67 Ethernet Cable (1 m)
93A051346
CAB-ETH-M03
M12-IP67 Ethernet Cable (3 m)
93A051347
CAB-ETH-M05
M12-IP67 Ethernet Cable (5 m)
93A051348
CBL-1534-0.2
Ethernet Adapter Cable (M12 4-pin male to RJ45 female)
93A050057
Software Management
Datalogic WebSentinel-005
Supervisor (up to 5 arrays)
93A101014
Datalogic WebSentinel-010
Supervisor (up to 10 arrays)
93A101015
Datalogic WebSentinel-020
Supervisor (up to 20 arrays)
93A101016
Datalogic WebSentinel-032
Supervisor (up to 32 arrays)
93A101017
Datalogic WebSentinel-064
Supervisor (up to 64 arrays)
93A101018
Datalogic WebSentinel-128
Supervisor (up to 128 arrays)
93A101019
Datalogic WebSentinel-256
Supervisor (up to 256 arrays)
93A101020
* Connection Boxes
CBX100
Compact Connection Box
93A301067
CBX500
Modular Connection Box
93A301068
CBX800
Gateway Connection Box
93A301077
BM100
Backup Module
93ACC1808
BA100
DIN Rail Adapters for CBX
93ACC1821
BA200
Bosch Adapters for CBX
93ACC1822
BA900
Two Cable Glands Panel
93ACC1847
Sensors
MEP-593
Photocell kit – PNP (PH-1)
93ACC1791
MEP-543
Photocell kit – NPN
93ACC1728
OEK-2
Optical encoder kit (10 m cable + spring)
93ACC1770
OEK-1
Optical encoder kit + 10 m cable
93ACC1600
Brackets
FBK-6000
Fast bracket kit (2 pcs)
93ACC1721
* DX6400 application software does not support any of the CBX500 Host Interface Module accessories nor the
BM150 Display accessory. Use the CBX800 Gateway for Host Interface Applications, (Fieldbus and non
Fieldbus).
DX6400 QUICK GUIDE
11
MECHANICAL INSTALLATION
The DX6400 reader can be positioned and installed in the best way possible as a result of the patented Step-A-
HeadTM feature. Thanks to the separation between Head and Base, you can modify the orientation of the decoder
base, and therefore display-keypad and connector panels, while keeping the optic head in the correct reading
position. The reading head and the decoder base can be rotated independently from each other allowing the
installation even in the most critical locations.
To rotate the head follow the given procedure:
1.
detach the head from the base by unscrewing the four fixing screws;
2.
rotate the head in the desired position;
3.
loosen but don't remove the two screws on top of the head;
4.
affix the head onto the base carefully aligning the four fixing screws and
progressively tightening them about half-way;
5.
completely tighten the two screws on top of the head;
6.
completely tighten the four fixing screws.
Step-A-Head™ Feature
The following diagrams give the overall dimensions of the reader and mounting bracket. They may be used for
their installation:
85
[3.35]
60
[2.36]
16.5
[0.65]
29.9
[1.18]
116.8
[4.60]
71.8
[2.83]
115.9
[4.56]
96.9
[3.82]
225.9
[8.89]
149.8
[5.90]
125.3
[4.93]
113.1
[4.45]
=
=
=
=
82
3.22
20
0.78
50
1.96
18
0.71 N°2
25
0.98
10
0.4
22
0.86
42
1.65
Ø4.1 N°2
Ø0.16 N°2
4.5 N° 4 SLOTS
0.18 N°4 SLOTS
82
3.22
50
1.96
35
1.37
50
1.96
72
2.83
100
3.93
4
0.15
130
5.12
126
4.96
106°
73.2
2.88
36
1.41
8.5 N°2 SLOTS
0.33 N°2 SLOTS
Ø8.5
Ø0.33
mm
inch
DX6400 Overall Dimensions
ST-237 Mounting Bracket Overall Dimensions
Head Screws
Fixing
Screw (4)
DX6400 QUICK GUIDE
12
Mount the scanner using the ST-237 mounting bracket which assures an angle of 16°, as indicated in the figure
below, in order to obtain an angle of 90° between the two scan lines. This guarantees an omni directional reading
of the barcode, if the code label satisfies the ACR™ 4 conditions (see Scanner Reference Manual for details).
DX6400 Mounting Position
WARNING
When installing several scanners, take care to position them correctly so that no laser beam
enters the reading window perpendicularly and at the same level of the output beam of the
other scanners. This condition could occur more frequently for side mounted applications. If
these precautions are not followed, it may occur that the laser of the blinded scanner starts
blinking due to an internal circuit which temporarily turns the laser off when detecting a
power anomaly. To resolve this problem, it is sufficient to slightly change the inclination and
position of one of the two scanners involved.
FLASH™ DYNAMIC FOCUS
The DX6400 has an innovative linear motor designed to control the focus position of the scanner via software.
This dynamic system, called FLASH™, is able to move the focus position rail to rail, from the minimum position to
the maximum position.
The FLASH™ functionalities (i.e. the driving modes of the linear motor) are programmed via the Genius™
software tool and can operate in the following modes:
-
Fixed mode: the focus is set to the desired position via software (expressed in cm);
-
Continuous mode: the focus position is continuously running from a minimum position to a maximum position
with a defined frequency;
-
Triggered mode: the focus position can be set depending on the received external input (photocell, barrier,
serial message, etc.);
-
D-Flash™ mode: the focus position can be set depending on the measured distance between the scanner
and the scanned object. This is the most innovative and flexible function that makes different software
implementations possible. The D-Flash™ development has been based on the minimum distance detected.
Thus, it can apply to the widest variety of applications. Further developments of D-Flash™ will be provided
according to the specific application needs.
DX6400 QUICK GUIDE
13
READING CONDITIONS
ANSI Grade B minimum
600 scans/sec per leg
The following tables describe the requirements for standard applications.
Minimum Code Height for Omnidirectional Reading (mm)
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.38
14
16
18
20
22
24
0.50
18
19
21
23
25
27
0.60
21
22
24
26
28
30
2/5 Inteleaved
Code Resolution (mm)
1.00
34
35
36
37
39
41
Table 1
Minimum Code Height for Omnidirectional Reading (mm)
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.38
12
13
15
17
19
21
0.50
15
16
17
19
21
24
0.60
18
19
20
21
23
26
Code 39
Code Resolution (mm)
1.00
28
29
30
31
32
34
Table 2
Minimum Code Height for Omnidirectional Reading (mm)
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.38
10
12
14
16
18
20
0.50
12
13
16
18
20
22
0.60
14
15
17
19
21
24
Code 128 – GS1-128
Code Resolution (mm)
1.00
22
23
24
26
28
30
Table 3
Minimum Code Height for Omnidirectional Reading (mm)
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.38
16
18
20
22
24
26
0.50
20
22
24
26
28
30
0.60
23
25
27
29
31
34
Codabar
Code Resolution (mm)
1.00
36
38
40
42
44
47
Table 4
Minimum Code Height for Omnidirectional Reading (mm)
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.38
11
12
13
15
17
19
0.50
13
14
15
16
18
20
0.60
15
16
17
18
19
22
EAN 8-13, UPC-A
Code Resolution (mm)
1.00
24
25
26
27
28
29
Table 5
DX6400 QUICK GUIDE
14
READING DIAGRAMS
DX6400-100-0XX – Resolution: 0.38 mm/15 mils
(in)
(cm)
(cm)
20
40
10
30
10
0
-10
-20
-30
-10
0
-40
0
-20
-60
0
-50 -60
-70
-80
-40
-30
-90 -100 -110
-50
-120 -130 -140 -150 -160 -170 -180
-70
-40
Note:
x = 0 and z = 0 correspond to the edge of the DX6400 scanner as shown in the figure above.
CONDITIONS
Code = Interleaved 2/5 or Code 39
PCS = 0.90
DX6400-100-0XX – Resolution: 0.50 mm/20 mils
(in)
(in)
(cm)
(cm)
20
40
10
30
10
0
-10
-20
-30
-10
0
-40
0
-20
-60
0
-50 -60
-70
-80
-40
-30
-90 -100 -110
-50
-120 -130 -140 -150 -160 -170 -180
-70
-40
Note:
x = 0 and z = 0 correspond to the edge of the DX6400 scanner as shown in the figure above.
CONDITIONS
Code = Interleaved 2/5 or Code 39
PCS = 0.90
z
x
z
x
DX6400 QUICK GUIDE
15
COMPLIANCE
See the DX6400 Reference Manual for the Declaration of Conformity.
LASER SAFETY
Figure A
Laser Safety Label
1
Identification Label
2
Figure B
Warning and Device Class Label
1
The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser
product according to CDRH regulations.
Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to
hazardous laser light.
There is a safety device which allows the laser to be switched on only if the motor is rotating above the threshold
for its correct scanning speed.
The laser beam can be switched off through a software command (see also the Genius™ Help On-Line).
LASER LIGHT EMITTED FROM THIS APERTURE
AVOID EXPOSURE TO BEAM
CAUTION - LASER LIGHT WHEN OPEN
AVOID EXPOSURE – LASER LIGHT
IS EMITTED FROM THIS APERTURE
Laser Safety Labels
DX6400
CAUTION-CLASS 3B
LASER LIGHT
WHEN OPEN
AVOID EXPOSURE
TO BEAM
LASER LIGHT - DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
MAX. OUTPUT RADIATION 1 mW
EMITTED WAVE LENGTH 630~680 nm
EN60825-1:2001
N2468
DATALOGIC AUTOMATION S.r.l. Via Lavino 265
40050 Monte San Pietro (BO) ITALY
MANUFACTURED VOLT
Amp.
JANUARY 2005
15-30 DC 1.5-0.7
MODEL No.
SERIAL No.
This product conforms to the applicable requirements
of 21CFR 1040 at the date of manufacture.
Warning and Device Class Label
Device Identification Label
The laser diode used in this device is classified as a Class 3B laser product according to EN 60825-1 regulations
and as a Class IIIb laser product according to CDRH regulations. Any violation of the optic parts in particular can
cause radiation up to the maximum level of the laser diode (35 mW at 630 ~ 680 nm).
1
1
2
DX6400 QUICK GUIDE
16
POWER SUPPLY
This product is intended to be installed by Qualified Personnel only.
-
All DX6400 Models:
This device is intended to be supplied by a UL Listed Power Unit marked “Class 2” or LPS power source
which supplies power directly to the scanner via the 25/26-pin connector.
CE COMPLIANCE
Warning:
This is a Class A product. In a domestic environment this product may cause radio interference in which case the
user may be required to take adequate measures.
FCC COMPLIANCE
Modifications or changes to this equipment without the expressed written approval of Datalogic could void the
authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference which may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his own expense.
PATENTS
This product is covered by one or more of the following patents.
U.S. patents: Re. 36,251; 5,992,740; 6,049,406; 6,347,740 B1; 6,394,352 B1; 6,443,360 B1; 6,629,639 B2;
6,742,710 B2; 7,161,685 B1; 7,195,162 B2.
European patents: 652,530 B1; 643,362 B2; 786,734 B1; 789,315 B1; 851,376 B1; 959,426 B9; 1,300,798 B1;
1,217,571 B1; 1,363,228 B1; 1.607,901 B1.
Japanese patents: 3,793,585 B2; 4,033,958 B2; 4,129,302 B2; 4,376,353 B2; 4,451,592 B2.