Datalogic Memor Operation & User’s Manual
Read Online
Read the Datalogic Memor Operation & User’s Manual online using the built-in PDF viewer.
Text of the manual
Datalogic ADC S.r.l.
Via S. Vitalino, 13
40012 Lippo di Calderara di Reno
Bologna - Italy
Telephone: (+39) 051-3147011
Fax: (+39) 051-3147205
©2008-2013 ADC S.r.l.
An Unpublished Work - All rights reserved. No part of the contents of this documentation or
the procedures described therein may be reproduced or transmitted in any form or by any
means without prior written permission of Datalogic ADC, Inc. or its subsidiaries or affiliates
("Datalogic" or “Datalogic ADC”). Owners of Datalogic products are hereby granted a non-
exclusive, revocable license to reproduce and transmit this documentation for the
purchaser's own internal business purposes. Purchaser shall not remove or alter any
proprietary notices, including copyright notices, contained in this documentation and shall
ensure that all notices appear on any reproductions of the documentation. Should future
revisions of this manual be published, you can acquire printed versions by contacting your
Datalogic representative. Electronic versions may either be downloadable from the Datalogic
website (www.datalogic.com) or provided on appropriate media. If you visit our website and
would like to make comments or suggestions about this or other Datalogic publications,
please let us know via the "Contact Datalogic" page.
Disclaimer
Datalogic has taken reasonable measures to provide information in this manual that is
complete and accurate, however, Datalogic reserves the right to change any specification at
any time without prior notice. Datalogic and the Datalogic logo are registered trademarks of
Datalogic S.p.A. in many countries, including the U.S.A. and the E.U.
Memor and the Memor logo are trademarks of Datalogic ADC S.r.l.
All other brand and product names may be trademarks of their respective owners.
Patents
This product is covered by one or more of the following patents.
Design Pat. Nos: EP 469,143; EP 1,582,024; AU 310182 S; CN 658612; HK 0601962.6; KR 30-
0466667; JP1325117; TW D118829; US D574,830 S.
US Pat. Nos: 5,992,740; 6,808,114 B1; 6,997,385 B2; 7,387,246 B2.
European Pat. Nos: 681,257 B1; 789,315 B1; 1,128,315 B1; 1,396,811 B1; 1,413,971 B1.
Additional patents pending.
REFERENCES ............................................................................................ vi
Conventions .................................................................................................. vi
Reference Documentation ............................................................................ vi
Services and Support .................................................................................... vi
GENERAL VIEW ........................................................................................ vii
1
INTRODUCTION .......................................................................................... 1
1.1
Datalogic Memor Description ........................................................................ 1
1.2
Available Models ........................................................................................... 3
1.3
Package Contents ......................................................................................... 4
1.4
Inserting a MicroSD Card .............................................................................. 5
1.4.1
Removing the MicroSD Card ........................................................................ 7
1.5
Accessories ................................................................................................... 8
2
BATTERIES AND MAINTENANCE ............................................................. 9
2.1
Charging the Battery Pack ............................................................................ 9
2.2
Replacing the Battery Pack ......................................................................... 12
2.3
Cleaning the Mobile Computer .................................................................... 16
3
CONNECTIONS ......................................................................................... 17
3.1
USB Connection ......................................................................................... 17
3.2
Connection to USB Peripherals .................................................................. 19
3.3
RS232 Connection ...................................................................................... 21
3.4
WLAN Connection ...................................................................................... 22
3.5
WPAN Connections .................................................................................... 24
3.6
Connection Cables ...................................................................................... 25
3.7
Wireless and Radio Frequencies Warnings ................................................ 26
4
USE AND FUNCTIONING .......................................................................... 28
4.1
Startup ........................................................................................................ 28
4.1.1
Using the Stylus .......................................................................................... 30
4.1.2
Using the Joystick ....................................................................................... 31
4.1.3
Windows CE Touch Screen Calibration ...................................................... 32
4.2
Data Capture ............................................................................................... 33
4.2.1
Laser Data Capture ..................................................................................... 34
4.2.2
Imager Data Capture................................................................................... 35
4.3
Description of the Keyboards ...................................................................... 37
4.3.1
Resetting the Datalogic Memor ................................................................... 40
4.4
Status Indicators ......................................................................................... 42
4.4.1
LED Status .................................................................................................. 42
4.4.2
Taskbar ....................................................................................................... 43
4.5
Control Panel .............................................................................................. 44
4.5.1
Data Capture Configuration ........................................................................ 45
Configure .................................................................................................... 46
4.5.3
Capture ....................................................................................................... 51
4.5.4
Buttons ........................................................................................................ 52
4.5.5
Registry ....................................................................................................... 53
4.5.6
Files Admin ................................................................................................. 54
4.5.7
Wireless Communications ........................................................................... 57
4.5.8
Stylus Calibration ........................................................................................ 58
4.5.9
Audio Settings ............................................................................................. 61
4.6
Connecting to other Computers .................................................................. 63
4.6.1
Windows Mobile® Device Center ................................................................ 63
4.6.2
Bluetooth® Manager Device Setup ............................................................. 64
4.6.3
FTP Server Setup ....................................................................................... 72
4.7
Backup Directory File Management ............................................................ 73
4.8
Datalogic Firmware Utility ........................................................................... 74
4.8.1
Retrieving a Firmware Image Update ......................................................... 74
4.8.2
Installing DFU on the Host PC .................................................................... 75
4.8.3
Updating the Firmware ................................................................................ 76
4.9
Datalogic Configuration Utility ..................................................................... 78
4.10
Datalogic Desktop Utility ............................................................................. 79
4.10.1
Administrative Options (Admin tab) ............................................................. 81
4.10.2
Setting Hot Keys ......................................................................................... 84
4.10.3
Internet Explorer Configuration ................................................................... 88
4.10.4
Modifying Windows Controls ....................................................................... 90
4.10.5
AppSelector Options (AppSelect tab).......................................................... 91
4.11
AppSelector (Application Selector) ............................................................. 94
5
TECHNICAL FEATURES ........................................................................... 95
5.1
Technical Data ............................................................................................ 95
5.2
Reading Diagrams ...................................................................................... 99
6
TEST CODES ........................................................................................... 101
SAFETY REGULATIONS ......................................................................... 105
General Safety Rules ................................................................................ 105
Power Supply ............................................................................................ 105
Laser Safety .............................................................................................. 106
LED Class ................................................................................................. 112
Radio Compliance ..................................................................................... 113
FCC Compliance ....................................................................................... 115
RF Exposure Information (SAR) ............................................................... 116
Industry Canada Compliance .................................................................... 117
SAR Compliance ....................................................................................... 117
WEEE Compliance ................................................................................... 118
China RoHS Pollution Control Logos ........................................................ 120
GLOSSARY .............................................................................................. 121
INDEX ....................................................................................................... 125
This manual uses the following conventions:
“User” refers to anyone using a Datalogic Memor mobile computer.
“mobile computer” and "Datalogic Memor" refer to Datalogic Memor mobile computer.
“You” refers to the System Administrator or Technical Support person using this
manual to install, configure, operate, maintain or troubleshoot a Datalogic Memor
mobile computer.
“Single Dock” refers to the Datalogic Memor Single Slot Dock.
The label artworks may be only a draft. Refer to the product labels for more precise
information.
REFERENCE DOCUMENTATION
For further information regarding Datalogic Memor refer to the SDK Help on-Line.
SERVICES AND SUPPORT
Datalogic provides several services as well as technical support through its website.
Please check our website at www.datalogic.com under “Support & Services”, then
“Automatic Data Capture”, and click on the links indicated for further information
including:
-
Downloads
- Manuals for the latest versions of user manuals and product guides.
- Software & Utilities for the latest firmware release for your product. You can
also click on the following link for direct access to this section:
www.datalogic.com/products_updates.
-
Service Program for warranty extensions and maintenance agreements.
-
Repair Centers for a list of authorised repair centers.
-
Technical Support Automatic Data Capture email form to contact our
technical support.
A) QVGA 64K Color Display
B) Good Read or User Programmable
LED
C) Charging Status LED
D) Speaker
E) Scan Key
F) Keyboard
G) Microphone
H) Strap with Stylus Holder
I)
Laser Safety Label
J)
Rear Speaker
K) ON/OFF Power Key
L)
Product Label (under battery)
M) Battery Cover
A
F
B
H
D
G
C
E
I
L
K
J
M
N) Data Capture Window*
O) DC Charger Connector
P) Communication/Charger Connector
(through cradle)
Q) Mini USB Communication Connector
(through cable)
* Remove protective film cover before use
N
O
P
Q
DATALOGIC MEMOR DESCRIPTION
The Datalogic Memor mobile computer maximizes a compact and light weight form
factor for ease of use and shirt pocket convenience without compromising durability.
Datalogic Memor features target applications found in field force automation, retail
stores, manufacturing and warehouses.
The computer architecture of the Datalogic Memor starts with the industry leading
XScale™ PXA310 microprocessor. Geared for computing requirements of real time
information management and communication. Memory of 128 MB RAM / 256 MB
Flash is sized for running multiple simultaneous applications, for managing large
databases or the use of thick applications when off-line autonomy is required. The
memory storage capacity can be increased through the user accessible Micro SD
Card Slot.
Microsoft Windows CE 5.0 with Microsoft WordPad and Internet Explorer 6.0
minimizes the operating system size for faster uploads and more storage space. A
software development kit (SDK) aids in creating applications for both of these
powerful Windows operating systems and alternative environments like Java Virtual
Machine.
Datalogic Memor provides voice and data wireless communication options to meet
the business need. A speaker and microphone equip the Datalogic Memor to handle
– VoIP phone calls or push-to-talk conversations. The Summit IEEE 802.11 abg
radio’s optimized transmit power and receiver sensitivity result in superior range with
a tailored user interface for easy configuration and consistent management.
Complimented by a CCX v4 security certification from Cisco, the Datalogic Memor
provides infrastructure compatibility focused on enterprise requirements for
encrypted communication and seamless roaming. Client side applications leverage
internet protocol connections for hands-free voice picking and push to talk
communications. Bluetooth® Wireless Technology connects headsets, printers and
other peripherals while eliminating cumbersome wires and costly replacement of
broken or damaged cables.
Two scanner options optimize the Datalogic Memor for the application needs. A laser
scanner tackles intensive applications where speed and a wide depth of field are
essential. Datalogic’s patented Green Spot good read feedback makes Datalogic
Memor’s laser scanner intuitive while reducing errors. The 2D scan engine option
leverages picture technology to capture a wide range of Linear, Stacked, and 2D
codes while also providing the flexibility to capture a signatures or drivers license.
Digital image decoding software reduces failed reads due to damaged and poor
quality barcodes while enabling the user to scan from almost any orientation.
1 DATALOGIC MEMOR™
2
1
Durability ratings protect the computing investment against accidental drops and
occasional exposure to liquids and dust. A touch color display provides an easy to
read interface in a wide range of lighting conditions. The phone keyboard layout and
four direction joystick increase associate efficiency. Push button battery lock provides
an easy to locking mechanism for quick, no hassle battery exchanges. Rechargeable
Lithium polymer batteries in two sizes customize capacity to the application.
Charging cradles include a communication cradles for RS232 and USB. A powered
vehicle dock and power adapter cable extend charging capabilities onto the road.
Powered by Wavelink® device maintenance and management tools makes the
Datalogic Memor a simple device to both deploy and maintain. Datalogic Firmware,
Desktop and Configuration Utilities complete the package with unprecedented ability
to customize device configuration to the use environment or process. Combined
these tools streamline deployment and management activities while providing
developer tools to further customize units for specific applications.
The Datalogic Memor is available in different models depending on the options it is
equipped with. All options are listed below:
•
communication options: 802.11 abg radio, Bluetooth®
•
data capture options: laser, imager
•
operating system: Windows CE 5.0, Windows Mobile 6.1
For further details about the Datalogic Memor models refer to the web site:
http://www.datalogic.com.
For further information regarding Windows CE refer to the website:
http://www.microsoft.com/windowsembedded.
The currently available models are:
•
944201016
DL-Memor+Batch+1DGS+CE5
Datalogic Memor, Batch, 128MB RAM/256MB Flash, 23-key Numeric, Std Laser
with Green Spot, CE 5.0
•
944201038
DL-Memor+802.11+BT+1DGS+CE5
Datalogic Memor, 802.11 abg CCX V4, Bluetooth, 128MB RAM/256MB Flash,
23-
key Numeric, Std Laser with Green Spot, CE 5.0
•
944201039
DL-Memor+802.11+BT+2D+CE5
Datalogic Memor, 802.11 abg CCX V4, Bluetooth, 128MB RAM/256MB Flash,
23-
key Numeric, Std 2D Imager, CE 5.0
•
944201040
DL-Memor+802.11+BT+1DGS+WM6.1
Datalogic Memor, 802.11 abg CCX V4, Bluetooth, 128MB RAM/256MB Flash,
23-key Numeric, Std Laser with Green Spot, WM 6.1
•
944201041
DL-Memor+802.11+BT+2D+WM6.1
Datalogic Memor, 802.11 abg CCX V4, Bluetooth, 128MB RAM/256MB Flash,
23-key Numeric, Std 2D Imager, WM 6.1
1 DATALOGIC MEMOR™
4
1
1.3
PACKAGE CONTENTS
The Datalogic Memor package contains:
−
1 Datalogic Memor mobile computer
−
1 AC/DC power supply
−
1 EU plug adapter
−
1 UK Plug Adapter
−
1 standard Mini USB cable
−
1 extensible stylus
−
1 rechargeable standard battery pack + cover
−
1 hand-strap with stylus holder
−
1 Quick Start Guide
−
1 Safety and Regulatory Addendum
−
1 Wavelink Avalanche Insert
−
1 End User License Agreement (EULA) Sheet
Any other packages will contain the accessories necessary for the Datalogic Memor
connection to the host computer and to the network: the cradle, one or more
connection cables.
Remove all the components from their packaging; check their integrity and compare
them with the packing documents.
Keep the original packaging for use when sending products to the
technical assistance center. Damage caused by improper
packaging is not covered under the warranty.
CAUTION
Rechargeable battery packs are not initially fully charged. Therefore
the first operation to perform is to charge them. See section 2.1.
NOTE
INSERTING A MICROSD CARD
The Datalogic Memor supports microSD memory cards. To access the microSD card
slot and insert the card, proceed as follows:
1.
Turn off the Datalogic Memor.
2.
Press the latch release button and pull the latch down:
3.
Remove the cover and the battery pack, then open the microSD card slot by
pulling up the locking plate:
1 DATALOGIC MEMOR™
6
1
4.
Shift the cardholder to the left and then pull it up; insert the microSD card with
the written part upward:
5.
Lock the card into place by pushing the cardholder down and then shifting it to
the right; pull the locking plate down:
6.
Close the battery cover properly, by pressing the latch release button and pulling
the latch down.
Removing the MicroSD Card
To remove the microSD card, follow the steps above to access the SD area, and
remove it from its slot.
Follow
proper
ESD
precautions
to
avoid
damaging
the
microprocessors in the Datalogic Memor or the microSD card itself.
Proper ESD precautions include, but are not limited to, working on
an ESD mat and ensuring that the operator is properly grounded.
Do not force the card. If you feel resistance, remove the card, check
the orientation, and reinsert it.
Do not use the microSD card slot for any other accessories.
CAUTION
1 DATALOGIC MEMOR™
8
1
1.5
ACCESSORIES
Cradles
94A151111 DL-Memor Single Cradle w Aux. Slot
94A151121 Dock Memor Vehicle w Power Adapter
94A151122 DL-Memor Single Ethernet-Usb_Host Cradle
94A151123 DL-Memor Multi Battery Charger
Batteries
94ACC1367 DL-Memor Large Capacity Battery CVR2
94ACC1368 DL-Memor Standard Battery CVR2
Power Supply
94ACC1324 PG5-30P35 AC/DC Power Supply EU/USA Plug
94ACC1334 PG5-30P35 AUS. Plug Adapter (10pcs)
94ACC1335 PG5-30P35 UK Plug Adapter (10pcs)
94ACC1339 PG5-30P35 EU. Plug Adapter (10pcs)
94ACC1369 DL-Memor Alkaline Adapter CVR2
Cables
94A051016 CAB-421 USB Type A-B-Mini Straight
94A051022 WIN-NET Serial CAB (HRS ST40x-18S-CV)
94A051024 USB A (4 pin F) to Mini A (5 pin M)
94A051966 Cable Memor 12 TO 24 V Power Adapter
Various
94ACC1328 DL-Memor Stylus Pen (10pcs)
94ACC1365 Headset Memor
94ACC1366 Softcase Memor w/Swivel
Use only a Datalogic approved power supply and cables. Use of an
alternative power supply will invalidate any approval given to this
device and may be dangerous.
NOTE
BATTERIES AND MAINTENANCE
9
2
2
BATTERIES AND MAINTENANCE
Rechargeable backup batteries and battery packs are not initially
fully charged. Therefore the initial operation to perform is to charge
them. See below.
NOTE
Annual replacement of rechargeable battery pack avoids possible
risks or abnormalities and ensures maximum performance.
CAUTION
2.1
CHARGING THE BATTERY PACK
The battery pack autonomy varies according to many factors, such
as the frequency of barcode scanning, RF usage, battery life,
storage, environmental conditions, etc.
NOTE
The battery icon on the Taskbar indicates when the battery pack is low.
It is possible to recharge the battery pack by connecting the power supply directly to
the Datalogic Memor.
Alternatively, it is also possible to recharge the battery pack by inserting the
Datalogic Memor into the single slot dock or the multi battery charger.
Moreover recharging is possible by USB Direct connection with the host computer,
but with longer charging times and only if the mobile computer off.
During the charging process the LED positioned at the right side of the display is red
constant. Once the charging process has been completed this LED is green constant
(see par. 4.4).
The stand alone battery pack may be recharged outside a Datalogic Memor using the
spare battery charging slot on the back of the single slot dock or the multi battery
charger.
1 DATALOGIC MEMOR™
10
2
Do not use the Datalogic Memor until batteries are charged for
minimum 4 hours.
CAUTION
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries according to the instructions.
CAUTION
Il y a risque d’explosion si la batterie est remplacée par une batterie
de type incorrect.
Mettre au rebut les batteris usagées confor mément aux instructions.
CAUTION
Even if the storage temperature range is wider, in order to achieve
the longest battery life, store the terminal and the spare batteries
between 20 to 30º C (68 to 86º F).
Datalogic Memor (including spare battery) should be charged at an
ambient temperature between 0° to +40 °C (+32° to +104 °F) to
achieve the maximum charging rate. Never charge the main device
or spare batteries in a closed space where excessive heat can build
up.
NOTE
The battery level may display incorrectly for several minutes after the
Datalogic Memor is disconnected from its charger if the charging
cycle is not completed.
NOTE
BATTERIES AND MAINTENANCE
11
2
The Datalogic Memor may get warm during charging; this is normal
and does not mean a malfunction.
NOTE
Use only a USB-IF compliant USB port as a charging source.
NOTE
1 DATALOGIC MEMOR™
12
2
2.2
REPLACING THE BATTERY PACK
To correctly replace the battery pack, proceed as follows.
1.
Turn off the Datalogic Memor.
2.
Press the latch release button and pull the battery latch down :
3.
Remove the cover and the battery pack.
BATTERIES AND MAINTENANCE
13
2
4.
Install the new battery pack, first insert the bottom (contacts) side, then the
upper side:
5.
Press the latch release button and pull the battery latch down to reinsert the
cover
WARNING
Installing, charging and/or any other action should be done by
authorized personnel and following this manual.
The battery pack may get hot, explode, ignite, and/or cause serious
injury if exposed to abusive conditions.
If the battery pack is replaced with an improper type, there is risk of
explosion and/or fire.
Do not place the battery pack in or near a fire or other heat source;
do not place the battery pack in direct sunlight, or use or store the
battery pack inside unventilated areas in hot weather; do not place
the battery pack in microwave ovens, in clothes dryers, in high
pressure containers, on induction cook surfaces or similar devices.
Doing so may cause the battery pack to generate heat, explode or
ignite. Using the battery pack in this manner may also result in a loss
of performance and a shortened life expectancy.
Use only a Datalogic approved power supply. The use of an
alternative power supply will void the product warranty, may cause
product damage and may cause heat, an explosion, or fire.
The area in which the units are charged should be clear of debris
and combustible materials or chemicals.
Do not use the battery pack of this terminal to power devices other
than this mobile computer.
1 DATALOGIC MEMOR™
14
2
WARNING
Immediately discontinue use of the battery pack if, while using,
charging or storing the battery pack, the battery pack emits an
unusual smell, feels hot, changes colour or shape, or appears
abnormal in any other way.
Do not short-circuit the battery pack contacts connecting the positive
terminal and negative terminal. This might happen, for example,
when you carry a spare battery pack in your pocket or purse;
accidental short–circuiting can occur when a metallic object such as
a coin, clip, or pen causes direct connection of the contacts of the
battery pack (these look like metal strips on the battery pack). Short–
circuiting the terminals may damage the battery pack or the
connecting object.
Do not apply voltages to the battery pack contacts.
Do not pierce the battery pack with nails, strike it with a hammer,
step on it or otherwise subject it to strong impacts, pressures, or
shocks.
Do not disassemble or modify (i.e. bend, crush or deform) the battery
pack. The battery pack contains safety and protection devices,
which, if damaged, may cause the battery pack to generate heat,
explode or ignite.
In case of leakage of liquid from the battery, avoid contact with liquid
the skin or eyes. If the contact occurs, immediately wash the affected
area with water and consult a doctor.
Do not solder directly onto the battery pack.
Do not expose the battery pack to liquids.
Avoid any knocks or excessive vibrations. If the device or the battery
is dropped, especially on a hard surface, you should take it to the
nearest Authorised Repair Centre for inspection before continuing to
use it.
Do not replace the battery pack when the device is turned on.
Do not remove or damage the battery pack’s label.
Do not use the battery pack if it is damaged in any part.
Battery pack usage by children should be supervised.
Collect and recycle waste batteries separately from the device in
compliance
with
European
Directive
2006/66/EC,
2011/65,
2002/96/EC and subsequent modifications, with US and China
regulatory laws and regulations about the environment.
BATTERIES AND MAINTENANCE
15
2
In order to maximize operating autonomy, the Datalogic Memor
checks its battery level at all times. If the battery is not
sufficiently charged, the Datalogic Memor will not turn on when
the ON/OFF Power button is pressed.
In this case, either substitute a sufficiently charged battery, insert
the Datalogic Memor into a powered cradle, or plug it into a wall
charger.
NOTE
To maximize battery life, turn off radios when they are not
needed.
NOTE
1 DATALOGIC MEMOR™
16
2
2.3
CLEANING THE MOBILE COMPUTER
Periodically clean the Datalogic Memor with a slightly dampened cloth.
Do not use alcohol, corrosive products or solvents.
You can use any standard mini USB cable to directly connect the Datalogic Memor to
a host computer to transfer data through the USB interface.
Key:
A
Host computer
C
Datalogic Memor
B
Standard Mini USB cable
Connection through the cable is compliant to 2.0 USB standard.
NOTE
A
B
C
1 DATALOGIC MEMOR™
18
3
The Single Dock can be connected to the host computer by any standard mini USB
cable.
Once the host computer has been turned on, insert the Datalogic Memor mobile
computer into the cradle.
Key:
A
Host computer
C
Single Slot Dock
B
Standard Mini USB cable
D
Power
Supply
(only
necessary
for
battery charging†)
Connection through the cradle complies to USB 1.1 standard.
NOTE
The actual data transfer speed can be appreciably lower than the
maximum theoretical speed.
NOTE
B
D
C
A
CONNECTION TO USB PERIPHERALS
You can connect the Datalogic Memor to a standard 101-key USB keyboard or to a
standard USB flash memory device. Connect the terminal to a standard A (4 pin
female) to mini A (5 pin male) USB cable. For all these devices maximum current
draw must be less than 100mA.
Key:
A
Keyboard with USB interface
C
94A051024 (Standard A to Mini A USB
cable)
B
Datalogic Memor
Key:
A
USB hard drive/ external
memory source
C
94A051024 (Standard A to Mini A USB
cable)
B
Datalogic Memor
Connect first the USB peripheral to the cable, and then the cable to
the Datalogic Memor.
NOTE
A
B
C
A
B
C
1 DATALOGIC MEMOR™
20
3
The Datalogic Memor works with most of the mentioned USB
peripherals. Datalogic cannot guarantee the interoperability of
Datalogic Memor with all devices on the market.
NOTE
Connection is compliant to USB 1.1 standard.
NOTE
The actual data transfer speed can be appreciably lower than the
maximum theoretical speed.
NOTE
You can use a cable to directly connect the Datalogic Memor to a host computer to
transfer data through the RS232 interface:
Key:
A
Host computer
C
Datalogic Memor
B
94A051022 WIN-NET
(HRS ST40X-18S-CV)
The Single Slot Dock can be connected to the Host by means of a standard null
modem cable such as Datalogic 94A051020 CAB-427 for 9-pin connections.
Once the host computer has been turned on, insert the Datalogic Memor mobile
computer into the dock.
Key:
A
Host Computer
C
Single Slot Dock
B
94A051020 CAB-427
RS232 Null Modem Cable
D
Power Supply (only necessary for battery
charging)∗
∗In this case the power supply is only necessary for battery charging. Insert the power supply
plug into the power jack on the base of the cradle and attach the power supply to a power
outlet.
A
B
C
A
B
C
D
1 DATALOGIC MEMOR™
22
3
3.4
WLAN CONNECTION
Datalogic Memor 802.11 abg radio models can communicate with the host using the
on-board Wi-Fi radio and an Access Point connected to a network.
Key:
A) Datalogic Memor
B) Access point
C) Host – Application Server
A
B
C
A
802.11 abg radio module is on by default. In order to avoid wasting
energy, you can switch it off using the Wireless Communications tab.
NOTE
Suspending the terminal powers off the 802.11 a/b/g radio and drops
the radio connection. When the terminal resumes, depending on the
radio power mode and security protocol selected, it may take up to
30 seconds for the 802.11 a/b/g radio driver to re-associate the radio
to the network.
NOTE
Area coverage and radio performance may vary, due to
environmental conditions, access points types or interference caused
by other devices (microwave ovens, radio transmitters, etc.).
NOTE
In case of heavy usage the Datalogic Memor may get warm; this is
normal and does not mean a malfunction.
NOTE
1 DATALOGIC MEMOR™
24
3
3.5
WPAN CONNECTIONS
Datalogic Memor Bluetooth® models can communicate with a Bluetooth® device,
such as a printer, within a range of 10 m, using the on-board Bluetooth® module.
Key:
A) Datalogic Memor
B) Bluetooth® printer
In order to extend battery life, the Bluetooth® module is off by
default. If you need to have Bluetooth® working, the module must be
powered on using the Wireless Communications tab (see par. 4.5.7),
and perform the Discovery procedure (see par. 4.6.2).
NOTE
Suspending the terminal powers off the Bluetooth® radio and drops
the piconet (Bluetooth® connection). When the terminal resumes, it
takes approximately 10 seconds for the Bluetooth® radio driver to re-
initialize the radio.
NOTE
Area coverage and Bluetooth® radio performance may vary, due to
environmental conditions or interference caused by other devices
(microwave ovens, radio transmitters, etc.).
NOTE
A
B
RS232 Direct Connection:
94A051022 WIN-NET SERIAL CAB (HRS ST40x-18S-CV)
RXD
TXD
3
10
2
9
4
DSR
Datalogic Memor™
side
HOST/PC side
9-pin (female)
1
6
13
15
TXD
RXD
DCD
DTR
RI
RI
CTS
RTS
7
12
8
11
RTS
CTS
DTR
14
8
9
GND
GND
7
5
DCD
DSR
Power Supply Polarity:
GND
VEXT
1 DATALOGIC MEMOR™
26
3
3.7
WIRELESS AND RADIO FREQUENCIES WARNINGS
Use only the supplied or an approved replacement antenna.
Unauthorized antennas, modifications or attachments could
damage the product and may violate laws and regulations.
WARNING
Most modern electronic equipment is shielded from RF signals.
However, certain electronic equipment may not be shielded against
the RF signals generated by the Datalogic Memor.
WARNING
Datalogic recommends persons with pacemakers or other medical
devices to follow the same recommendations provided by Health
Industry Manufacturers Associations for mobile phones.
Persons with pacemakers:
•
Should ALWAYS keep this device more than twenty five (25) cm
from their pacemaker and/or any other medical device;
•
Should not carry this device in a breast pocket;
•
Should keep the device at the opposite side of the pacemaker
and/or any other medical device;
•
Should turn this device OFF or move it immediately AWAY if
there is any reason to suspect that interference is taking place.
•
Should ALWAYS read pacemaker or any other medical device
guides or should consult the manufacturer of the medical device
to determine if it is adequately shielded from external RF energy.
In case of doubt concerning the use of wireless devices with an
implanted medical device, contact your doctor.
WARNING
Turn this device OFF in health care facilities when any regulations
posted in these areas instruct you to do so. Hospitals or health care
facilities may use equipment that could be sensitive to external RF
energy.
WARNING
RF signals may affect improperly installed or inadequately shielded
electronic systems in motor vehicles. Check with the manufacturer
or its representative regarding your vehicle. You should also
consult the manufacturer of any equipment that has been added to
your vehicle.
WARNING
An air bag inflates with great force. DO NOT place objects,
including either installed or portable wireless equipment, in the area
over the air bag or in the air bag deployment area. If a vehicle’s
wireless equipment is improperly installed and the air bag inflates,
serious injury could result.
WARNING
Turn off the device when in any area with a potentially explosive
atmosphere. Observe restrictions and follow closely any laws,
regulations, warnings and best practices on the use of radio
equipment near fuel storage areas or fuel distribution areas,
chemical plants or where any operation involves use of explosive
materials.
Do not store or carry flammable liquids, explosive gases or
materials with the device or its parts or accessories.
Areas with a potentially explosive atmosphere are often, but not
always, clearly marked or shown.
Sparks in such areas could cause an explosion or fire, resulting in
injury or even death.
WARNING
To safely disable the radio modules (WiFi/BT) do not power off the
mobile computer, but use the Wireless Communications tab (see
par.4.5.7).
WARNING
1 DATALOGIC MEMOR™
28
4
4
USE AND FUNCTIONING
The use of the Datalogic Memor depends on the application software loaded.
However there are several parameters that can be set and utilities that can be used
to perform some basic functions such as data capture, communications, file
management, etc
4.1
STARTUP
The Datalogic Memor turns on when the battery pack or the external supply is
inserted and the ON/OFF Power button is pressed.
After the battery pack is installed, use the [ON/OFF] key to turn the mobile computer
on and off.
As soon as the mobile computer is on, the Windows CE 5.0 desktop will appear on
the screen. Wait a few seconds before starting any activity so that the mobile
computer completes its startup procedure.
Desktop
Control Panel
Use the stylus (par. 4.1.1) or joystick (par. 4.1.2) as suggested to select icons and
options.
The mobile computer goes into power-off (low power with display and keyboard
backlight off), when it is not used for more than a programmable timeout, which is
USE AND FUNCTIONING
29
4
defined in the POWER applet of the Control Panel. In this mode it can be awakened
(resuming operation) by the [ON/OFF] key.
The mobile computer can also be awakened or suspended
programmatically.
NOTE
1 DATALOGIC MEMOR™
30
4
4.1.1
Using the Stylus
The stylus selects items and enters information. The stylus functions like a mouse.
Double Tap:
Double tap the screen with the stylus to open items and select
options.
Drag:
Hold the stylus on the screen and drag across the screen to
select text and images. Drag in a list to select multiple items.
Tap-and-hold:
Tap and hold the stylus on an item to see a list of actions
available for that item. On the pop-up menu that appears, tap the
action you want to perform.
To recalibrate the touch screen use the Stylus applet (see par. 4.6.7).
Use only original Datalogic styluses supplied with the product itself.
In harsh applications, use of screen protectors should be taken into
consideration, in order to extend the touch screen operating life.
To prevent damage to the screen, do not use sharp devices or any
device other than the Datalogic provided stylus.
Do not apply too much pressure when touching the screen.
For applications where an intensive use of the touch screen is
foreseen, please consider that touch screen components are subject
to progressive wear.
CAUTION
USE AND FUNCTIONING
31
4
4.1.2
Using the Joystick
The joystick selects items and enters information. The joystick can work like the
directional arrow keys of a PC keyboard or can function like a mouse and control the
mouse pointer. It is possible to switch between the two functioning modes by
pressing blue modifier + BKSP keys in sequence.
Arrow Keys Mode
(default):
Move in the four directions: move forwards, backwards,
upwards or downwards within text fields, scroll through a
Menu list or browse among folder files.
Press down: selects the current function (like the Enter
key).
Mouse Mode:
Move in the four directions: move the mouse pointer
forwards, backwards, upwards or downwards.
Press down: like the left click of the mouse.
1 DATALOGIC MEMOR™
32
4
4.1.3
Windows CE Touch Screen Calibration
In Windows CE, at the very first Datalogic Memor startup, following a clean boot to
restore the Registry to default values, the mobile computer startup (see par. 4.1) is
preceded by the touch screen calibration screen.
The user must calibrate the touch screen (see par. 4.5.7)
Touch Screen Calibration Screen
USE AND FUNCTIONING
33
4
4.2
DATA CAPTURE
To capture data tap Start > Settings > Control Panel > double tap Decoding:
To configure and enable data capture parameters refer to par. 4.5.1.
1 DATALOGIC MEMOR™
34
4
4.2.1
Laser Data Capture
To scan barcodes, point the Datalogic Memor laser model onto the code from a
distance within the reading range while pressing the SCAN key.
The lighted band emitted by the laser must completely cross the barcode as shown in
the figure below.
If the scan has taken place correctly:
−
the Good Read LED glows steadily Green for a configurable time;
−
if enabled, the Good Read Beep plays;
−
if enabled, the GreenSpot projects a green spot onto the bar code image.
Remove the protective film cover over the data capture window
before use.
NOTE
USE AND FUNCTIONING
35
4
4.2.2
Imager Data Capture
The Datalogic Memor Imager captures a picture of the entire bar code. The omni-
directional scanning does not require that the operator orient the bar code to align
with the scan pattern.
To read a 1D or 2D code, simply point the Datalogic Memor Imager model onto the
code and press the SCAN Key or the pistol trigger.
The Datalogic Memor Imager uses an intelligent aiming system pattern, similar to
those on cameras, indicating the field of view, which should be positioned over the
code:
Aiming System
If the aiming system pattern is centered over the entire symbology as shown in the
following figure, either wait for the timeout or release the Scan key or the trigger to
capture the image.
A red beam illuminates the code, which is captured and decoded. You will get a good
read.
1 DATALOGIC MEMOR™
36
4
Linear barcode
2D Matrix symbol
ÌBX3ÉÎ
Relative Size and Location of Aiming System Pattern
The field of view changes its size as you move the reader closer or farther away from
the code. The field of view indicated by the aiming system pattern will be smaller
when the Datalogic Memor Imager is closer to the code and larger when it is farther
from the code.
Symbologies with smaller bars or elements (mil size) should be read closer to the
unit. Symbologies with larger bars or elements (mil size) should be read farther from
the unit. (See par. 5.1 for further details).
If the scan has taken place correctly:
−
the Good Read LED glows steadily Green for a configurable time;
−
if enabled, the Good Read Beep plays.
USE AND FUNCTIONING
37
4
4.3
DESCRIPTION OF THE KEYBOARDS
The Datalogic Memor comes with a 23-key alphanumeric keyboard + ON/OFF key +
joystick.
1 DATALOGIC MEMOR™
38
4
Main Keys Function
KEY
FUNCTION
The SCAN key starts data capture.
The joystick lets you move forwards, backwards,
upwards or downwards, scroll through a Menu list,
browse among folder files or select functions if pressed
down.
It can work in two functioning modes: Arrow Keys Mode
and Mouse Mode. It’s possible to switch between them
by pressing blue modifier + BKSP keys in sequence (see
par. 4.1.2).
Yellow modifier (toggle key): when pressed before a
standard key, it enables the character or function printed
in yellow above the key.
Blue modifier (one shot key): when pressed before a
standard key, it enables the character or function printed
in blue above the key
The ON/OFF Power button powers the Datalogic Memor
ON or OFF. It is placed on the upper left side of the
terminal.
The ALPHA key is used to alternate numeric and
alphanumeric use of the 10 numeric keys.
Special Function Icons
ICON
FUNCTION
After a yellow modifier key press, it opens the Start menu.
After a yellow modifier key press, it opens the file manager.
After a yellow modifier key press, it switches ON/OFF the display backlight.
ICON
FUNCTION
After a yellow modifier key press, it opens the Start menu.
After a yellow modifier key press, it opens the file manager.
After a yellow modifier key press, it switches ON/OFF the display
backlight.
After a blue modifier key press, it switches ON/OFF the keyboard
backlight.
1 DATALOGIC MEMOR™
40
4
4.3.1
Resetting the Datalogic Memor
There are several reset methods for the Datalogic Memor.
A warm boot terminates an unresponsive application and clears the working RAM,
but preserves both the file system and the registry.
A cold boot forces all applications to close and clears working RAM and files not
resident on the persistent flash memory. Registry is restored from persistent memory
if available or returned to factory default.
A clean boot restores the Datalogic Memor to factory configuration: registry and file
system return to factory default.
Warm Boot
A warm boot closes all applications, clears the working RAM, but preserves the file
system and registry. If an application "hangs" initiate a warm boot to terminate the
application.
To perform a warm boot, press these keys simultaneously:
Cold Boot
A cold boot is a complete reset of the Datalogic Memor in which all applications are
forcibly closed and RAM is completely cleared. Registry is restored from persistent
memory if a saved copy is available (see 4.7.2) and RAM file system completely
erased. You will lose any applications and data (registry too) which are not stored in
persistent flash memory.
A cold boot is necessary when the Windows CE operating system locks up and the
warm boot command does not work.
To perform a cold boot, press these keys simultaneously:
USE AND FUNCTIONING
41
4
Clean Boot
A clean boot is a cold boot that causes the device to be restored to factory
configuration. The Datalogic Memor will reset to its factory configuration, clear the
working RAM and initialize the file system. You will lose any applications and data
stored in persistent flash memory. At the next startup the system will ask to
recalibrate the touch screen.
To perform a clean boot, follow these steps:
1.
Perform a Cold Boot (see Cold Boot).
2.
Quickly release all the keys when the screen goes black.
3.
Within 1 second press and hold down the Esc and 0 keys until the left orange led
starts blinking.
4.
Release the Esc and 0 keys.
5.
Enter 1 to proceed with the Clean Boot sequence. Enter 0 to cancel the Clean
Boot and proceed with a Cold Boot.
Warm Boot
Cold Boot
Clean
Boot
Registry
Preserved
Restored from flash (if available)
Factory
default
Flash Disk
(Backup Folder)
Preserved
Preserved
Clean
disk
RAM File System
Preserved
Reinitialized (factory default)
Factory
default
1 DATALOGIC MEMOR™
42
4
4.4
STATUS INDICATORS
4.4.1
LED Status
The Datalogic Memor provides two different LEDs signaling the mobile computer
status.
LED
STATUS
Good Read and
General Purpose
(left side)
Green
It is constant for a configurable time to
signal that a successful read has
occurred.
Green/ Red
It is also available to the application
program.
Charging Status
(right side)
Green
It is solid once the charging process has
been completed (full charge).
Red
It is solid while charging.
Off
if the charging stops due to high
temperature, failures etc.
Orange
it is constant while in pre-charge status
USE AND FUNCTIONING
43
4
4.4.2
Taskbar
Windows CE Taskbar
The Taskbar provides information about the time, the battery level, the keyboard
function, and the decoding status.
ICONS
DESCRIPTION
Time and Battery Icons
It displays the time.
In Windows CE, they are representative of five
different icons indicating the battery level. The
icon is partially green when the power left is
>20% and partially red colored when the power
left is <20%.
It indicates that the battery is charging
Keyboard Status Icons
It indicates that the blue FUNC key has been
pressed and is going to affect the next key press.
It indicates that the yellow FUNC key has been
pressed and is going to affect the next key press.
It indicates that the ALPHA key has enabled the
selection of the characters printed in orange.
It indicates the NUMERIC key selection, the
ALPHA key has not been pressed.
It indicates that the ALPHA key has enabled the
selection of the characters printed in orange and
the Capslock is active.
It indicates that the keyboard is locked.
Decoding Status Icons
It indicates that the decoder is active (green), not
active (grey).
1 DATALOGIC MEMOR™
44
4
4.5
CONTROL PANEL
From the Start menu, tap Settings then Control Panel.
Windows CE Control Panel
USE AND FUNCTIONING
45
4
4.5.1
Data Capture Configuration
From the Windows CE Taskbar, tap the "Decoding" icon to open a drop–down menu.
By selecting the Info item from this drop-down menu you can access information
about the Scanner and the Software; the Configure item opens the configuration
applet (Data Capture Configuration Window), while Capture accesses the data
capture applet (Data Capture Window), which enables code reading.
The last menu item (Wedge) enables Wedge Emulation.
Decoding can also be accessed from the Control Panel.
1 DATALOGIC MEMOR™
46
4
4.5.2
Configure
The Configuration applet contains the barcode scanning configuration parameters in
a directory tree structure. The available barcode parameters are divided into two
groups: Reader Parameters and Scan Parameters.
The Reader Parameters depend on the type of scanner module installed on the
mobile computer and allow barcode configuration (i.e. enable/disable Code 39, check
digit control, etc.).
The Scan Parameters are common to all scanner modules and allow control of the
scanning device (i.e. beeper control, LED control, laser timeout, etc.).
Each Data Capture screen window corresponds to a branch of the tree, and the
name of the current branch is displayed at the bottom of each screen window.
Data Capture Configuration Window
The screen format shows two columns where the left column indicates branches or
parameters. Branches have three dots in the right column (...). You can navigate
through the tree structure using the stylus or keyboard arrows directly on the item
field or from the menu.
Parameters have their corresponding current values in the right column. You can edit
parameter values using the stylus or keyboard arrows directly on the item field or
from the menu. To change a value for example, select the line of the value to be
changed, choose Edit from the Parameter Menu then choose a new value from the
values listed in the box (see following figures).
USE AND FUNCTIONING
47
4
Selecting Data Capture Setup Parameters
Alternatively using the stylus, you can tap once directly on the value on the right
column; continue tapping until the desired value is reached.
To activate a new configuration select the File ->Save Menu to send the new
configuration to the barcode decoding software and save the new configuration. This
will save the configuration to non-volatile memory preventing loss at the next system
reset.
Reader Parameters
The barcode reading parameters and values are dependent upon the type of scanner
module mounted in your mobile computer. For a detailed list of parameters and of
their configuration procedures, please refer to the SDK Help file on the CD.
Scan Parameters
The Scan Parameters are common to all scanner modules and allow control of the
scanning device. The Scan parameters are described as follows:
ScanTimeout: the maximum time, in milliseconds, during which the scanner remains
on without decoding any barcode.
BeepType: if set to dual tone, the good read beep is a sequence of high and low
pitch sounds. If set to monotone, the beep is a single pitch sound.
BeepDuration: the time interval, in milliseconds, during which the beeper will sound
when the scanner reads a code. To disable the beeper, set this value to 0.
1 DATALOGIC MEMOR™
48
4
BeepFrequency: determines the frequency in Hertz of the beeper.
GoodReadSound: is the beep sound emitted when the scanner reads a code.
LedDuration: the length of the good-read led pulse, in milliseconds.
LedPulses: the number of times the good-read led pulse is emitted when the
scanner reads a code.
ContinuousMode: disables the effect of the ScanTimeout parameter.
KeyboardEmulation: if enabled all scanned data are transformed into keyboard
events and can therefore be displayed and saved to a file as if input from the mobile
computer keyboard.
SoftTrigger: when enabled, the laser can be turned on/off by the application
software.
ScanAlwaysOn: enables the scanner for barcode reading independently from the
application software.
GreenSpotDuration: determines the duration (measured in milliseconds) of the
green spot feedback, which provides a “good read” green dot directly on the code,
where the operator usually tends to be looking.
NotPrintableChar: if set to “Remove”, all not printable characters included in the
scanned data are deleted and the final barcode will include only printable characters.
ScanButton: enables/disables the scan button. If the scan button is disabled, the
reader can be triggered under software control.
USE AND FUNCTIONING
49
4
Default Settings
The following tables contain the default values for the major barcode setup
parameters, according to the type of scan engine mounted on the mobile computer.
For a complete list of parameters and of their configuration procedures, please refer
to the SDK Help file on the CD.
SCAN PARAMETERS
LASER
MODELS
IMAGER
MODELS
ScanTimeout
5000
Not available
BeepType
Dual tone
Not available
BeepDuration
20
Not available
BeepFrequency
2000
Not available
GoodReadSound
Beep
Beep.wav
LedDuration
200 ms
200 ms
LedPulses
1
1
ContinuousMode
Disabled
Disabled
KeyboardEmulation
Enabled
Enabled
SoftTrigger
Enabled
Enabled
ScanAlwaysOn
Disabled
Disabled
GreenSpotDuration
1000
Not available
NotPrintableChar
Leave
Leave
ScanButton
Enabled
Enabled
BARCODE SYMBOLOGY
SPECIFIC READER
PARAMETERS
LASER
MODELS
IMAGER
MODELS
UPC A
Enabled
∗
UPC E
Enabled
EAN 8
Enabled
EAN 13
Enabled
UPC/EAN/JAN
Not available
Enabled
Code 39
Enabled
Enabled
Code 39 Full ASCII
Disabled
Disabled
Code 32
Disabled
Not available
2/5: Interleaved
Enabled
Enabled
2/5: Industrial
Disabled
Not available
2/5: Matrix
Disabled
Not available
Code 128
Enabled
Enabled
EAN 128
Enabled
Disabled
CODABAR
Disabled
Enabled
∗ In the Imager models these codes may only be enabled or disabled as a group by the UPC/EAN/JAN family
selection (see a few lines below).
1 DATALOGIC MEMOR™
50
4
BARCODE SYMBOLOGY
SPECIFIC READER
PARAMETERS
LASER
MODELS
IMAGER
MODELS
MSI
Disabled
Not available
Plessey
Disabled
Not available
Code 93
Disabled
Enabled
Code 11
Disabled
Not available
GS1 Databar
Disabled
Enabled
GS1 Databar Omnidirectional
Disabled
Not available
GS1 Databar General
Not available
Enabled
GS1 Databar Limited
Disabled
Enabled
GS1 Databar Expanded
Disabled
Enabled
PDF - 417
Not available
Enabled
Data Matrix
Not available
Enabled
QR
Not available
Enabled
POSTNET
Not available
Disabled∗
PLANET
Not available
Japan Post
Not available
Australia Post
Not available
KIX Code
Not available
Royal Mail Code (RM4SCC)
Not available
∗ These codes may be enabled individually but are disabled as a group.
USE AND FUNCTIONING
51
4
4.5.3
Capture
The Data Capture applet (Capture) enables code reading.
Data Capture Window
Data Capture can also be enabled through the Configuration applet by selecting File
->Scanner from the main menu, or by enabling the parameter Scan Always On in the
Scan Parameters branch.
Enabling the Data Capture
1 DATALOGIC MEMOR™
52
4
4.5.4
Buttons
You can use the Buttons Tab to associate specific keys, such as -, with
specific applications.
From the control panel main window, double tap the DL Buttons icon.
On the Buttons tab, customize the program hardware buttons to launch your most
used applications. Select the button you want to assign a function to, and then
browse to select the application to be assigned.
You can also select to wake up the terminal by the SCAN key.
USE AND FUNCTIONING
53
4
4.5.5
Registry
The Registry stores information that are necessary to configure the system for
applications and hardware devices. The Registry also contains information that the
operating system continually references to during operation.
From the Control Panel, double tap the “Registry Admin” icon. Two functions are
available:
-
Save Registry allows permanently saving the Windows configuration (example:
custom configuration of screen desktop background color, or network adapter
configuration) to non-volatile memory (‘Save’ button).
-
Restore Default Registry allows restoring the initial factory default configuration
(‘Restore Default’ button). After restoring the factory default configuration, you
must perform a warm boot.
1 DATALOGIC MEMOR™
54
4
4.5.6
Files Admin
The Files Admin applet enables control of the permanence of files in the Windows
CE System Folder.
Files Admin Main Window
Two functions are available:
Save Session: with this button all files will be permanently saved in the \Windows
directory in non-volatile memory. This function guarantees the steady maintenance of
every file produced during the current working session - even of sub-directories and
relevant files - with the exception of the files belonging to the FLASH image.
These current working session files will be backed-up in the \Backup\Windows
directory.
At the next cold boot, the files previously saved in the \Backup\Windows directory will
be restored to the Windows directory.
Safe Setup: with this button, the installation of software programs will be saved to
non-volatile memory (Backup directory). Before doing this, it will be checked that the
Backup directory has enough space to save the files. If the directory space is not
enough, an error message will be shown and the program will exit the Safe Setup
function.
USE AND FUNCTIONING
55
4
Two activating procedures are available for Safe Setup:
-
Select an installation file (for example, a .CAB cabinet file) from the Safe Setup
mask.
Safe Setup First Mask
Then select \Windows or a relevant sub-directory in the path box. Then, Safe
Setup will recognize the new files and directories present in the \Windows
directory, and will copy them to the \Backup\Windows directory. At the next cold
boot, these files will be restored (see par. 4.9).
-
Simply skip the first mask either by closing it or by pressing the ESC key. When
it closes, a new mask will pop up: it will enable any type of installation (even
remote ones like ActiveSync® installations). Make sure the installation directory
is \Windows or one of its sub-directories. After installation, tap OK: Safe Setup
will save the new files in the \Backup\Windows directory.
USE AND FUNCTIONING
57
4
4.5.7
Wireless Communications
The Wireless Communications applet provides management of the 802.11 abg radio
and the Bluetooth modules.
From the Control Panel, double tap the ‘Wireless Communications’ icon:
1 DATALOGIC MEMOR™
58
4
4.5.8
Stylus Calibration
You might need to recalibrate the touch screen (i.e. when you attempt to select one
item with the stylus, another item is erroneously selected).
To recalibrate the touch screen, complete the following steps:
1.
From the Control Panel main window, double tap Stylus to open the “Stylus
Properties” window:
2.
Adjust Double-Tap sensitivity if needed or desired:
USE AND FUNCTIONING
59
4
3.
Tap ‘Calibration’ to open the Calibration screen. Tap ‘Recalibrate’:
4.
Carefully press and briefly hold stylus on the center of the target. Repeat as the
target moves around the screen. Press the Esc key to cancel the stylus
calibration:
1 DATALOGIC MEMOR™
60
4
5.
Press the Enter key or tap the screen to accept the new calibration settings.
Press the Esc key to keep the old settings.
New calibration settings are persistently saved in the Registry.
Startup Stylus Calibration
When starting the terminal, a stylus calibration screen comes up if valid calibration
settings are not available. This happens in the following circumstances:
1.
At the first startup of the terminal.
2.
After restoring registry default settings using the applet Registry Admin and
performing a warm boot.
3.
After a Clean Boot.
4.
After a Firmware Update (see section 4.8.3)
USE AND FUNCTIONING
61
4
4.5.9
Audio Settings
There are two applets that control volume: Audio and Volume & Sounds.
Audio
From the control panel main window, double tap the ‘Audio’ icon:
The Audio applet allows to set the recording volumes of the main microphone and of
the headset microphone. Also, it allows to set the headset volume when the user is
listening to an audio file.
Audio Window
1 DATALOGIC MEMOR™
62
4
Volume & Sounds
From the control panel main window, double tap the Volume & Sounds icon:
The Volume & Sounds applet configures audio features of the rear speaker and
appears as follows:
Volume & Sounds Window
USE AND FUNCTIONING
63
4
4.6
CONNECTING TO OTHER COMPUTERS
There is more than one way to connect the Datalogic Memor to a host PC running
Windows. Each requires specific connections in order to function properly.
4.6.1
Windows Mobile® Device Center
The desktop application Windows Mobile® Device Center gives you the ability to
synchronize information between a desktop computer and your Datalogic Memor.
Synchronization compares the data on the Datalogic Memor with that on the desktop
computer and updates both with the most recent information.
Windows Mobile Device Center is only compatible with Windows Vista and Windows
7; if you run Windows XP or earlier, you have to download Microsoft ActiveSync.
You can establish a connection to your Datalogic Memor through the following
interfaces:
−
USB either directly or through the Single Dock
−
RS232 either directly or through the Single Dock
−
Bluetooth® (see par. 4.6.2)
To establish a partnership between the Datalogic Memor and a host PC, start
Windows Mobile® Device Center and follow the steps below:
1.
Connect the Datalogic Memor to the host PC. Windows Mobile® Device Center
configures itself and then opens.
2.
On the license agreement screen, click Accept.
3.
On the Windows Mobile Device Center’s Home screen, click Set up your
device.
4.
Select the information types that you want to synchronize, then click Next.
5.
Enter a device name and click Set Up.
When you finish the setup wizard, Windows Mobile Device Center synchronizes the
mobile computer automatically.
The Datalogic Memor running Windows CE does not come equipped
with Microsoft Office Outlook or any other application that allows
users to view contact, calendar, e-mail, or task data. Users can view
files copied to the Datalogic Memor by WMDC's file synchronization
feature.
NOTE
1 DATALOGIC MEMOR™
64
4
4.6.2
Bluetooth® Manager Device Setup
Using the Datalogic Memor to connect to another device
To create a Bluetooth® pairing between your device and another device that has
Bluetooth® capabilities, ensure that the two devices are turned on, discoverable, and
within close range.
1.
From the control panel, double tap the ‘Bluetooth Manager” icon:
2.
From the Bluetooth Manager control panel tap ‘Connections’.
USE AND FUNCTIONING
65
4
3.
Search for available Bluetooth® devices by tapping the button for the type of
device you want (Printer, Serial or All) or tap Discovery > Discover to skip this
step. The Datalogic Memor will search for Bluetooth® devices within range.
If you attempt to set up a connection when the Bluetooth® radio is
disabled, you will receive a message reminding you that the radio is
turned off, and asking if you want to turn it on. Tap Yes if you need to
enable the Bluetooth® radio.
NOTE
4.
Once searching is complete, Bluetooth® device Profiles will be displayed in the
Discovery tab. You can set up a connection to a device in the list by selecting
the device and then tapping the 'Connect' button:
1 DATALOGIC MEMOR™
66
4
To create a pairing:
1.
Select a service:
2.
Configure any encryption, authentication, or virtual port options required by the
service selected.
USE AND FUNCTIONING
67
4
Icon
Service
Dialup Networking
Printer
Object Push (OPP) Object Exchange (OBEX)
ActiveSync
Human Interface Device (HID) - Keyboard
Serial
Personal Area Network (PAN)
Modem
Headset
Handsfree
Virtual Port allows you to specify the incoming port, which is used to communicate
serially with an incoming device just as if it were a physical COM port. This option is
available only if you have selected a Printer or Serial service.
1 DATALOGIC MEMOR™
68
4
You can also select Encrypt or Authenticate from the Bluetooth® control panel to
apply or modify those settings.
1.
To require Authentication, check the checkbox, then tap OK.
2.
If required, the Authentication Request dialog will then open, requesting that you
enter a PIN. Use the Input Panel or the keyboard to type the PIN.
3.
Tap OK to complete.
The dialog will also appear when an Authentication request is received from another
device.
USE AND FUNCTIONING
69
4
Once you have set up a pairing, you can view the settings by double-tapping its
name from the Connections tab. Tap the arrow to change the Virtual Port, or Delete
to remove the device pairing. Tap Sync to initiate a Sync (available only if the service
is an ActiveSync connection).
1 DATALOGIC MEMOR™
70
4
Using your device to connect to the Datalogic Memor
Before turning on Bluetooth®, ensure that the two devices are within close range and
that both Bluetooth-enabled devices are discoverable.
1.
From the control panel main window, double tap the Bluetooth Manager icon to
open the Bluetooth Manager control panel.
2.
Tap Settings. The Settings tab allows you to enable or disable the Bluetooth®
radio and specify settings for Incoming Connections.
USE AND FUNCTIONING
71
4
3.
Select or clear the “Enable Bluetooth Radio” check box.
If you’re going to be attaching a serial device (i.e. a scanner) to the Datalogic
Memor, use the Port control to select a virtual COM port to use for the
connection.
5.
Tap ‘Find Me’ if you want to make the Datalogic Memor discoverable to other
Bluetooth® devices for 60 seconds, allowing them to set up a connection.
By default, Bluetooth® is turned off. If you turn it on, and then turn off
your device, Bluetooth® also turns off. When you turn on your device
again, Bluetooth® turns on automatically.
NOTE
1 DATALOGIC MEMOR™
72
4
4.6.3
FTP Server Setup
The Datalogic Memor Windows CE Operating System includes a sample File
Transfer Protocol (FTP) server. FTP is used for copying files to and from remote
computer systems over a network using TCP/IP. You can establish a connection to
your Datalogic Memor using its FTP Server through the following interfaces:
WLAN using the 802.11 abg radio
Proceed as follows:
1.
Create a registry file (extension .reg) to setup and enable FTP Server
communication. A simple example file for anonymous logon is given below:
REGEDIT4
[HKEY_LOCAL_MACHINE\Comm\FTPD]
"DefaultDir"="\\"
"AllowAnonymousUpload"=dword:00000001
"UseAuthentication"=dword:00000000
"BaseDir"="\\"
"IsEnabled"=dword:00000001
"LogSize"=dword:00001000
"DebugOutputMask"=dword:00000017
"DebugOutputChannels"=dword:00000002
"IdleTimeout"=dword:0000012c
"AllowAnonymous"=dword:00000001
"AllowAnonymousVroots"=dword:00000001
2.
Copy this file to the Datalogic Memor using ActiveSync®.
3.
Launch the .reg file from the Datalogic Memor.
4.
Perform a warm boot on the Datalogic Memor.
5.
From the PC > Explorer address bar (or running an FTP Client from the PC),
enter the Datalogic Memor IP address.
For more information on FTP Client/Server connections
refer to the following web page:
http://msdn2.microsoft.com/en-
us/library/aa922316.aspx.
NOTE
USE AND FUNCTIONING
73
4
4.7
BACKUP DIRECTORY FILE MANAGEMENT
All of the Windows CE 5.0 system files reside in RAM (volatile memory) except for
the Backup directory, which resides in FLASH (non-volatile memory). Therefore the
contents of the Backup directory are persistent even if the mobile computer is re-
booted or the battery pack is changed.
You can save your more important files that you don't want to lose due to mobile
computer re-boot, in the Backup directory or create a sub-directory within Backup.
Even though the Windows Directory resides in RAM, it often contains files or sub-
directories created by the user or by installation programs that you don't want to lose
at re-boot. To keep these files persistent it is necessary to copy them to the directory
\Backup\Windows. This directory doesn't exist originally (only Backup exists), and
therefore it must be created. At the next cold boot, before activating the shell,
Windows CE 5.0 will copy the contents including all sub-directories of
\Backup\Windows to \Windows.
Likewise, to maintain files that must be run at Windows CE 5.0 startup, (i.e. .exe, .lnk,
.vb, .htm, etc.), it is necessary to copy them to the directory \Backup\Startup. This
directory does not exist originally (only Backup exists), and therefore it must be
created. The application programs will be run after any type of re-boot (both software
and cold boot).
As an alternative to the Safe Setup function, it is possible to copy the .cab files to the
directory \Backup\Cabfiles (the Cabfiles sub-directory doesn't exists originally and
must therefore be created) and perform a mobile computer cold boot to have the
application installed. Once these files are copied to the directory \Backup\Cabfiles,
the application will be run after each re-boot.
From the second cold boot on, a message may be displayed such as " is already installed. Re-install?". This message blocks the boot process.
Press the [Enter] key to continue the system initialization.
Even if the entire Windows Mobile file system reside in FLASH (non-volatile
memory), the mechanism described above is supported also on Windows Mobile for
backward compatibility.
1 DATALOGIC MEMOR™
74
4
4.8
DATALOGIC FIRMWARE UTILITY
The Datalogic devices are equipped with a field upgradeable firmware mechanism.
Firmware updates are available on the Datalogic website:
http://www.datalogic.com/eng/support-services/automatic-data-
capture/downloads/software-utilities-sw-2.html.
After you have downloaded the desired update, there are several ways you can
update the firmware on your device.
−
Use Wavelink Avalanche™ if you have multiple Datalogic devices to update.
For more information refer to the dedicated section of the Wavelink website:
http://www.wavelink.com/Datalogic-device-downloads.
−
If Wavelink Avalanche™ is not available or you have only a few Datalogic
devices to update, use the Datalogic Firmware Utility (DFU), described below,
to install or update the firmware using an ActiveSync connection.
The following sections provide procedures for the retrieval and installation of the
most current firmware image onto a Datalogic device.
4.8.1
Retrieving a Firmware Image Update
The following instructions use Internet Explorer to retrieve the most current firmware
image.
1.
Launch Internet Explorer on your PC and navigate to the Datalogic website.
2.
Navigate to the Downloads section of the website.
3.
Using the device selection fields, select the file you want to download, then
click Save to begin copying the files to your local machine (or local network
location).
USE AND FUNCTIONING
75
4
4.8.2
Installing DFU on the Host PC
Datalogic Firmware Utility (DFU) provides administrators with a field upgrade
mechanism. You must have Microsoft® ActiveSync (for Windows XP devices) or
Windows Mobile® Device Center (for Windows 7 and Vista devices) already loaded
and running on the host PC to use DFU. Refer to par. 4.7.1 for more information
about Windows Mobile® Device Center.
Prior to installing, you must remove any previous versions of DFU
installed on the host PC.
NOTE
To install the Datalogic Firmware Utility, complete the following steps on the PC:
1.
Go to the Datalogic website and download the most current version of the
Datalogic Firmware Utility. Unzip the file, then double-click to run DFU_Setup.
exe.
2.
Click OK to continue once you have removed previous versions of DFU.
3.
The Welcome to DFU Setup Program screen opens.
−
Please exit all Windows applications before running this installer.
−
Click Next to continue the Setup.
4.
Follow the onscreen instructions to complete the installation.
1 DATALOGIC MEMOR™
76
4
4.8.3
Updating the Firmware
After copying the firmware image to the host PC (see par. 4.10.1) and installing DFU
(see par. 4.8.2), you can upgrade the firmware on your Datalogic device.
The following steps require that you have already established an
ActiveSync or Windows Mobile Device Center connection between
the host computer and the Datalogic device.
NOTE
1.
Go to Start > Programs > Datalogic > DFU > Datalogic Firmware Utility.
2.
Verify that ActiveSync is selected by clicking Communications > WMDC/
ActiveSync.
3.
Click browse (...) and navigate to the location where you saved the firmware
file for your terminal.
4.
Select the current *.out file and click Open.
5.
Click Update.
6.
DFU will compare the selected firmware image with the firmware already
loaded on the device; if the image is compatible with the connected device,
DFU will proceed to update the firmware image on your device.
After the firmware of your device has been updated, DFU will automatically
perform a warm reset of the device.
1 DATALOGIC MEMOR™
78
4
4.9
DATALOGIC CONFIGURATION UTILITY
Datalogic Configuration Utility (DCU) is a Datalogic Windows-based utility tool
allowing the uploading, modifying and downloading of the configuration of a Datalogic
device. Configuration settings include Scanner, Control Panel, and Datalogic
Desktop Utility (DDU). The DCU installer is downloadable from the Datalogic website
(http://www.datalogic.com/eng/support-services/automatic-data-
capture/downloads/software-utilities-sw-2.html).
DCU functions in both direct (with an ActiveSync connection) and indirect (with
Wavelink Avalanche™) modes.
In direct mode, connect a device through ActiveSync and then click on the Get from
Device icon to receive the device’s current configuration.
Once loaded, the Configuration Tree (on the left side of the window) is used to
navigate the device’s configuration. The right side of the window is a work area
where the values of different parameters may be set for each branch of the
configuration tree. Click on the parameter group branch to open it and inspect the
parameters you wish to modify.
After altering the device’s configuration, the new configuration can be sent to the
terminal by clicking on the Send to Device icon.
Reference the Wavelink Avalanche™ documentation on the Wavelink website
(www.wavelink.com/Datalogic-device-downloads) for a description of indirect mode
for DCU, which will allow you to update the configuration of multiple devices
simultaneously over Wi-Fi.
USE AND FUNCTIONING
79
4
4.10 DATALOGIC DESKTOP UTILITY
Datalogic Desktop Utility (DDU) allows administrators to configure Windows® CE and
Embedded Handheld devices to control individual user access. This includes the
ability to:
•
Prevent users from changing your device OS settings.
•
Define keys to access specific functionality/programs.
•
Use Application Selector to replace desktop with a selection of authorized
applications
•
Internet Explorer access restriction, configuration and customized recovery
mechanisms.
To open DDU for the first time, tap Start > Settings > Control Panel > or Start >
Programs > Device tools > and then double tap the icon for “Datalogic Desktop
Utility”.
1 DATALOGIC MEMOR™
80
4
These options are available from all screens:
COMMAND
DESCRIPTION
OK
Tap OK to apply the settings and modifications you have
made in the DDU tabs. OK saves every modifications.
X
Tap X to cancel the settings and modifications you have
made in the DDU tabs. X cancels all modifications you have
made in DDU.
USE AND FUNCTIONING
81
4
4.10.1
Administrative Options (Admin tab)
When you open the DDU control panel, the “Admin” tab appears.
COMMAND
DESCRIPTION
Enable Datalogic Desktop
Select/tap this checkbox to activate the DDU functions
such as Windows Access Restrictions and Application
Selector.
Enter Password
Enter a password in the text box. This allows the user to
specify a password when this utility is launched. By
default the password is “1234”. A password can consist
of all standard keyboard characters.
Re-Enter Password
Carefully re-enter the password in the second text box.
Set Password
Select/tap “Set Password” to enable the password.
To change or remove the password, enter a new value,
re-enter the new value, and select/tap “Set Password”.
Set Defaults
Select/tap “Set Defaults” to reset the default values of
all the functions on all the tabs. After you select this
option, you will receive a prompt to verify this selection.
1 DATALOGIC MEMOR™
82
4
Setting a Password
To set a password:
1.
Enter a password in the field. This allows the user to specify a password when
this utility is launched. By default the password is “1234”.
Be sure to record the Password for future reference.
NOTE
2.
Re-enter the password in the second field.
3.
Select/tap “Set Password” to enable the password.
4.
Select/tap “OK” to close the “Set Password Confirmation” dialog.
You must select/tap “Set Password” prior to exiting DDU in order to
store and activate your new password. It is not necessary to select
“Enable Datalogic Desktop”.
NOTE
If you select/tap “Set Defaults” it will remove all custom settings and
restore all the factory default settings, except a previously set
password.
CAUTION
Changing a Password
To change to a new password:
1.
Enter a new value in the “Enter Password field”.
2.
Re-enter the new value in the “Re-enter Password” field.
3.
Select/tap “Set Password”.
USE AND FUNCTIONING
83
4
Removing a Password
To remove a password:
1.
Enter blanks in both “Password” fields.
2.
Select/tap “Set Password”.
Password Request Dialog Box
Once the password is set, the next time you open the “Datalogic Desktop Utility”, the
DDU Password dialog box opens.
This dialog box will only open if a password was defined.
1.
Type in your password using either the keypad on the unit, or using the stylus on
the soft input panel (SIP).
If you enter an incorrect password, the system will prompt you to input the
correct one.
2.
Select/tap “OK” to verify the password. Or tap “X” to cancel.
1 DATALOGIC MEMOR™
84
4
4.10.2
Setting Hot Keys
You can use Hot Keys (HKeys) Tab to associate specific keys, such as -,
with specific applications. You can also create a new Hot Key combinations. Select
the HKeys tab to access these options.
For example, you could set to launch a sample application like:
\Windows\pword.exe.
COMMAND
DESCRIPTION
Hot Key
This pull-down list displays the available function keys
to define. Select the desired one from the list.
New
Select/tap to specify a new Hot Key, not on the Hot Key
list. This opens a new dialog, shown in Figure 4.
Delete
Tap to delete the selected Hot Key. You can only delete
the Hot Keys you have added. You cannot delete
-.
Associated Function
This pull-down list displays the available functions.
Select either Application or Action.
Application
Displays path to the selected application.
USE AND FUNCTIONING
85
4
Browse
Select/tap
to browse for application files. You can
associate an executable program with the specified Hot
Key.
Arguments
Type the command-line arguments that are needed for
the specified application. This option is only available
when Application is selected in the Associated Function
pull-down list.
Action
Specify an action to associate with a Hot Key. This list
includes: SIP, toggle Taskbar, Datalogic Config Admin,
and Application Switcher. This option is only available
when Action is selected in the Associated Function pull-
down list.
The is the key initially assigned to DDU Admin.
If you wish to assign this key to a different function, you must first select an
unassigned Hot Key and assign it to the Action - DDU Admin. You can then go back
and reassign the FKey to something else.
Datalogic device
19-key models
Numeric
F1-F10
Alpha keys
Side/top triggers
Hot Keys Available
1 DATALOGIC MEMOR™
86
4
Adding a new Hot Key
When you select ‘New’ on the HKeys tab, this opens the Add New Hotkey dialog box.
To define a new Hot Key, complete the following steps:
1.
Enter the key combination to define a new Hot Key in the Enter Key textbox.
2.
The Note displays important information indicating Hot Keys that should not be
used.
3.
Select/tap OK to save the New Hot Key. If you select/tap X, the key will not be
saved.
COMMAND DESCRIPTION
Enter Key
Enter the desired key combination in this text box to define a Hot Key.
OK
Select/tap OK to add the specified Hot Key.
X
Select/tap X to cancel the specified Hot Key.
Make sure you do not attempt to add a Hot Key that is already defined.
NOTE
USE AND FUNCTIONING
87
4
It is possible for the keyboard wedge to activate assigned Hot Keys
using alphanumeric characters. Barcodes containing characters
associated with assigned Hot Keys will trigger the action or
application assigned to that Hot Key.
CAUTION
1 DATALOGIC MEMOR™
88
4
4.10.3
Internet Explorer Configuration
Tap the IE (Internet Explorer) tab to access the IE Configuration option. Use the IE
Error Redirection option to provide customized recovery from common IE errors.
When an error occurs, the browser can redirect access to a specified error page with
instructions on how to recover from the problem.
COMMAND DESCRIPTION
Error Type
The Error Types pull-down list displays available IE Error Types:
(400) Invalid Syntax, (403) Request Forbidden, (404) Object Not
Found, (406) No Response Format, (410) Page Doesn't Exist, (500)
Internal Server Error, (501) Server Can't Do That, Generic Error, Server
Is Busy, Couldn't Find Server, URL Syntax Error, Request Cancelled,
Not Available Offline.
Error Page
Edit this textbox to associate a website or html file with the specified
error.
Assign
as
Default
Select/tap to set a specified error page as the default. A confirmation
dialog opens to ask if the default error page applies to all errors.
Browse
Select/tap to browse for files.
Enable
Address
Bar
Select/tap this check box to show the IE address bar.
IE Address Bar
IE Menu Bar
IE Tool
IE Status Bar
USE AND FUNCTIONING
89
4
COMMAND DESCRIPTION
Enable
Tool Bar
Select/tap this check box to show the IE toolbar.
Enable
Status Bar
Select/tap this check box to show the IE status bar.
Enable
Menu Bar
Select/tap this check box to show the IE menu bar.
Internet Options
Tap Internet Options on the IE tab to open the Windows CE Internet Options control
panel. Customize these settings as necessary.
The Internet Options control panel applet is part of the Microsoft®
Windows® CE operating system.
For more information on the Windows CE operating system, please
refer to the Microsoft website at http://www.microsoft.com/.
NOTE
The DDU allows you to cancel prior to applying your changes.
However, any settings modified in the Internet Options control panel
applet through the DDU interface will be applied even if you later
cancel the your modifications in the DDU.
CAUTION
1 DATALOGIC MEMOR™
90
4
4.10.4
Modifying Windows Controls
Select/tap the “Win” (Windows Controls) tab to access the Windows Controls option.
Use Windows controls to allow or restrict access to Windows system functions.
You can disable normal Windows functions such as the taskbar, leaving nothing but
a blank workspace. This allows applications to be run in full screen mode and
prevents users from accidental or unauthorized use of the taskbar, Internet Explorer,
and any other resident applications.
COMMAND
DESCRIPTION
Show Taskbar
Select/tap Show Taskbar to specify that the taskbar is shown
or hidden.
Taskbar Enabled
Select/tap Taskbar Enabled to specify whether the taskbar is
accessible. This option is only available when the Show
Taskbar is checked.
Start Menu Enabled
Select/tap Start Menu Enabled to specify whether the Start
menu is accessible or not. This option is only available when
both Show Taskbar and Task Bar Enabled are checked.
Windows CE
Desktop Enabled
Select/tap Windows CE Desktop Enabled to specify that the
desktop icons are accessible or not.
WinCE
Desk
Start Menu
Taskbar
USE AND FUNCTIONING
91
4
4.10.5
AppSelector Options (AppSelect tab)
Tap the Application Selector (“AppSelect” Tab) to edit, add, or delete applications for
the application selector.
Application Selector Options
Enable Application Selector
Select/tap
“Enable
Application
Selector”
to
enable/disable
the
application
selector.
When
enabled, the Application Selector replaces the
desktop
and
allows
only
authorized
use
of
applications.
Show status icons
Enable or disable the status icons view (see par.
4.10.3). The status icons can be configured on the
Status tab of DDU.
Authorized Applications
This is a list of applications that the user can access.
Application Selector Commands
New
Select/tap “New” to create a new application entry.
Edit
Select/tap “Edit” to edit the selected entry.
Del
Select/tap “Del” to delete the selected entry.
Up/Down
Select/tap “Up/Down” to move an entry up or down in
the ListView.
1 DATALOGIC MEMOR™
92
4
Add Applications
The “Add Application” dialog opens when you tap either “New” or “Edit”. From the
“Add Application” dialog the administrator can configure and/or add/change a new
application entry in the list.
Applications with the “Run Application at Startup” option enabled will start
automatically when the Application Selector starts up.
COMMAND
DESCRIPTION
Application Title
Type the name of the application in this textbox in the
way you wish it to appear for the user.
Executable
Displays the path for the executable file which you want
to run.
Browse
Select/tap
to browse for the desired executable file.
The results of this search are placed in the “Executable”
textbox.
Arguments
Type any command line arguments to be used when an
application is executed.
Icon File
Displays the path/link to the desired icon file.
Browse
Select/tap
to browse for the desired icon file. The
results of this search are placed in the “Icon File”
textbox.