Pridiom CS494U-BPY Operation & User’s Manual
Read Online
Read the Pridiom CS494U-BPY Operation & User’s Manual online using the built-in PDF viewer.
Text of the manual
INVERTER SPLIT TYPE
ROOM AIR CONDITIONER
-
CS494U-BPY(UL)
202000192389
20110625
Before using your air conditioner, please read
this manual carefully and keep it for future reference.
Read This Manual
Inside you will find many helpful hints on how
to use and maintain your air conditioner properly.
Just a little preventative care on your part can
save you a great deal of time and money over
the life of your air conditioner. You'll find many
answers to common problems in the chart of
troubleshooting tips. If you review the chart of
Troubleshooting Tips first, you may not need
to call for service.
The design and specifications are subject to change without prior notice for
product improvement. Consult with the sales agency or manufacturer for details.
PDF created with pdfFactory Pro trial version www.pdffactory.com
DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection
of such waste separately for special treatment is necessary.
It is prohibited to dispose of this appliance in domestic household waste.
For disposal, there are several possibilities:
A) The municipality has established collection systems, where electronic waste can
be disposed of at least free of charge to the user.
B) When buying a new product, the retailer will take back the old product at least
free of charge.
C) The manufacture will take back the old appliance for disposal at least free of
charge to the user.
D)
As old products contain valuable resources, they can be sold to scrap metal
dealers.
Wild disposal of waste in forests and landscapes endangers your health when
hazardous substances leak into the ground-water and find their way into the food
chain.
When using this air conditioner in the European countries, the following
informations must be followed:
SOCIABLE REMARK
SAFETY PRECAUTIONS
OPERATING INSTRUCTIONS
CARE AND MAINTENANCE
OPERATION TIPS
TROUBLESHOOTING TIPS
Sociable remark.......................................................................................................................2
Warning ..................................................................................................................................3
Caution ...................................................................................................................................4
Parts names ........... ...............................................................................................................5
Special functions .....................................................................................................................6
Operating temperature.............................................................................................................7
Manual operation ....................................................................................................................7
Airflow direction control ..........................................................................................................8
How the air conditioner works ................................................................................................9
Care and maintenance ..........................................................................................................10
Operation tips ............ ..........................................................................................................12
Troubleshooting tips .............................................................................................................14
Contact an authorised service technician for repair or maintenance of this unit.
Contact the authinstaller for installation of this unit.
Young children should be supervised to ensure that they do not play with the
air conditioner.
If the power cord is to be replaced, replacement work shall be performed by
authorised personnel only.
Installation work must be performed in accordance with the national wiring
standards by authorised personnel only.
This appliance is not intended for use by persons(including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
CAUTION
PDF created with pdfFactory Pro trial version www.pdffactory.com
To prevent injury to the user or other people and property damage, the following instructions
must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
The seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
Meanings of symbols used in this manual are as shown below.
WARNING
Always do this.
Never do this.
CAUTION
This symbol indicates the possibility of injury or damage to property.
Connect with the power
properly.
Do not modify power cord
length or share the outlet
with other appliances
Always ensure effective
earthing.
Disconnect the power if
strange sounds, smell, or
smoke comes from it.
Ventilate room before operating air
conditioner if there is a gas leakage
from another appliance.
Otherwise, it may cause
electric shock or fire due to
heat generation.
excess
It may cause electric shock
or fire due to heat generation.
No earthing may cause
electric shock.
It may cause fire and
electric shock.
It may cause explosion, fire and, burns.
It may cause electric shock
due to heat generation.
or fire
It may cause electric shock.
It may cause failure of
machine or electric shock.
It contains contaminants and
could make you sick.
It may cause fire and
electric shock.
It may cause electric shock
or fire.
This could damage your
health.
No installation may cause
fire and electric shock.
It may cause electric shock.
It may cause an explosion or fire.
It may cause failure and
electric shock.
Do not operate or stop the
unit by switching on or off
the power.
Do not operate with wet
hands or in damp
environment.
Do not allow water to run
into electric parts.
Do not drink water drained
from air conditioner.
Do not use the power cord
close to heating appliances.
Do not damage or use an
unspecified power cord.
Do not direct airflow at
room occupants only.
Always install circuit
breaker and a dedicated
power circuit.
Do not open the unit
during operation.
Do not use the power cord near
flammable gas or combustibles, such
as gasoline, benzene, thinner, etc.
Do not disassemble or
modify unit.
WARNING
Use the correctly rated
breaker or fuse.
There is risk of fire or
electric shock.
SAFETY PRECAUTIONS
CAUTION
When the air filter is to be
removed, do not touch the
metal parts of the unit.
It may cause an injury.
Do not clean unit when
power is on as it may cause
fire and electric shock, it may
cause an injury.
Operation with windows
opened may cause wetting
of indoor and soaking of
household furniture.
When the unit is to be
cleaned, switch off, and turn
off the circuit breaker.
Stop operation and close
the window in storm or
hurricane.
Use caution when unpacking
and installing. Sharp edges
could cause injury.
Do not clean the air
conditioner with water.
Water may enter the unit and
degrade the insulation. It may
cause an electric shock.
This could injure the pet or
plant.
Do not put a pet or house
plant where it will be
exposed to direct air flow.
Ventilate the room well
when used together
with a stove, etc.
An oxygen shortage
may occur.
Do not use this air cond-
itioner to preserve preci-
sion devices, food, pets,
plants, and art objects.
It may cause deterioration
of quality, etc.
It may cause failure of
product or fire.
Do not use for
special purposes.
Turn off the main power
switch when not
sing
the unit for a long time.
u
If water enters the
unit, turn the unit off
and disconnect the
power , contact a
qualified service
technician.
It may cause failure of
appliance or accident.
Appearance may be
deteriorated due to change
of product color or
scratching of its surface.
Do not place obstacles
around air-inlets or inside
of air-outlet.
Do not use strong detergent
such as wax or thinner. Use
a soft cloth for cleaning.
If bracket is damaged, there
is concern of damage due to
falling of unit.
There is danger of fire or
electric shock.
Ensure that the installation bracket of
the outdoor appliance is not damaged
due to prolonged exposure.
Do not place heavy object on the
power cord and take care so that
the cord is not compressed.
Operation without filters
may cause failure.
Always insert the filters
securely. Clean filter
once every two weeks.
PDF created with pdfFactory Pro trial version www.pdffactory.com
All the pictures in this manual
are for explanation purpose
only. Your air conditioner may
be slightly different.
The actual shape shall prevail.
1.Displaywindow
2.Frontpanel
3.Panelframe
4.Chassis
5.Airfilter
6.Panelbrace
7.Manualcontrolbutton
8.Connectingpipe
9.Drainhose
10.Remotecontrollerholder
11.Remotecontroller
12.
13.
14. Stop valve
Connecting cable
Connective pipe
Indoor unit
Outdoor unit
6
5
7
1
2
3
4
9
8
11
Air outlet
Air inlet
Air inlet(rear)
Air inlet(side)
Air outlet
13
14
12
10
Display window
Signal receptor
DEFROST operation display
Displayed when the air conditioner
starts defrosting automatically or
when the warm air control feature is
activated in heating operation.
This display is separated into five
zones. The zones illuminate based
on the compressor current frequency.
For example, higher frequency
will illuminate more zones.
Operation Frequency display
Special feature
CLEAN AIR display(optional)
Displayed when CLEAN AIR
feature is activated.
TIMER display
during Timer operation.
Displayed
DIGITAL DISPLAY
Displays the current setting temperature
and malfunction code when the air
conditioner is in operation. When SELF
CLEAN feature is activated, it displays
,,
,,
AUTO operation display
Displayed during Auto operation.
Improving the quality of indoor air is one of
the mission of an air conditioner. This air
conditioner is equipped with ionizer or
Plasma Dust Collector(Depending on
specific onfiguration of the model). With
the anions generated by Ionizer, the air
circulation of the air conditioner fills the
room with refreshing, natural and healthy
air. The PlasmaDust Collector generates
an high voltage ionization zone, through
which the air is converted to plasma.
Inside the air most of the dust, smoke, and
pollen particles are captured by the
electrostatic filter.
CLEAN AIR function(on some models)
SELF CLEAN function
Follow Me function
To activate the Follow Me feature, point
the remote control towards the unit and
press the Follow Me button. The remote
display is actual temperature at its
location. The remote control will send
this signal to the air conditioner every 3
minutes interval until press the Follow
Me button again. If the unit does not
receive the Follow Me signal during any
7 minute interval, the Follow Me mode
will be cancelled automatically.
The remote control serves as a remote
thermostat allowing for the precise
temperature control at its location.
Function used after the Shut Down of
cooling operation to clean the Evaporator
and keep it as fresh for the next operation.
This function is only available under
COOL(AUTO COOL, FORCED COOL)
and DRY mode.
Before select the function, it is recomm-
ended to run the air conditioner under
Cooling operation for about half an hour.
Once the Self Clean function is activated,
all TIMER setting will be cancelled.
During Self Clean operation, when press
the SELF CLEAN button on the remote
controller again will stop the operation
and turn off the unit automatically.
Note:
The unit will operate as following
sequence :
FAN ONLY mode at Low fan speed--
Heating operation with LOW fan speed
(applicable to cooling & heating modles
only) ---FAN ONLY operation--Stop
Operation---Turn off.
When turns off the unit on COOL, DRY,
AUTO (Cool) mode, the air conditioner
will continue operating for about 10 minutes
(depending on models) at LOW fan speed.
This will help to dry up the condensed
water inside the evaporator, and prevent
the breeding of mildew.
Under Anti-mildew operation, do not
restart the air conditioner until the unit is
completely off.
Anti-mildew function
(on some models)
PDF created with pdfFactory Pro trial version www.pdffactory.com
Airflow direction control
Range
Range
Vertical
louver
(three places)
Adjust the air flow direction properly otherwise, it
might cause discomfort or cause uneven room
temperatures.
Adjust the horizontal louver using the remote
controller.
Adjust the vertical louver manually.
Perform this function while the unit is in operation.
Use the remote controller to adjust the air flow
direction. The horizontal louver can be moved at
a range of 6 for each press, or swing up and down
automatically. Please refer to the
REMOTE
CONTROLLER OPERATION MANUAL
for details.
To set the vertical air flow(Up--Down) direction
O
Move the vertical louver manually to adjust the air flow
in the direction you prefer.
: Before adjusting the vertical louvers, the
supply power must be disconnected.
For some models, the vertical louver can be adjusted
by using the remote controller. Please refer to the
REMOTE CONTROLLER OPERATION MANUAL
for details.
To set the horizontal air flow direction (left - right)
IMPORTANT
Do not operate the air conditioner for long periods with
the air flow direction set downward in cooling or
dehumidifying mode. Otherwise, condensation may
occur on the surface of the horizontal louver causing
moisture to drop on to the floor or on furnishings.
Do not move the horizontal louver manually unless it is
necessary. Always use the remote controller.
When the air conditioner is started immediately after it
was stopped, the horizontal louver might not move for
approximately 10 seconds.
Open angle of the horizontal louver should not be set
too small, as COOLING or HEATING performance may
be impaired due to too restricted air flow area.
Do not operate unit with horizontal louver in closed
position.
When the air conditioner is connected to power (initial
power), the horizontal louver may generate a sound for
10 seconds, this is a normal operation.
CAUTION
,,
,,
,,
,,
Manul operation can be used temporarily in case the remote controller is disable or
maintenance necessary.
OPERATING INSTRUCTIONS
Manual operation
NOTE: This manual does not include Remote Controller Operations, see the
<> packed with the unit for details.
Operating temperature
Front panel
Manual control
button
Manual control
button
Side view
Mode
Temperature
Room temperature
Outdoor temperature
1. If air conditioner is used outside of the above conditions, certain safety protection
features may come into operation and cause the unit to function abnormally.
2. Room relative humidity less than 80%. If the air conditioner operates in excess of this
figure, the surface of the air conditioner may attract condensation. Please sets the vertical
air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
3. Optimum performance will be achieved within these operating temperature.
For the unit adopts an Electric Heater, when the outside ambient temperature
is below 0 C(32 F), we strongly recommend you to keep the machine plugged in order to
guarantee it running smoothly.
Suggestion:
O
O
CAUTION:
For the convenience of operation, the
manual control button is designed on the
right side of the panel frame.
One press of the manual control button
will lead to the forced AUTO operation. If
press the button twice within five seconds,
the unit will operate under forced COOL
operation.
This button is used for testing purposes
only. You had better not choose it.
To restore the remote controller operation,
use the remote controller directly.
CAUTION:
1
2
●
●
NOTE: The unit must be turned off before
operating the manual control button. If the
unit is operational, continue pressing the
manual control button until the unit is off.
PDF created with pdfFactory Pro trial version www.pdffactory.com
Cleaning the Grille, Case and Remote Controller
A cloth dampened with cold water may be used
on the indoor unit if it is very dirty. Then wipe it
with a dry cloth.
Do not use a chemically treated cloth or duster to
clean the unit.
Do not use benzine, thinner, polishing powder, or
similar solvents for cleaning. These may cause
the plastic surface to crack or deform.
Never use water hotter than 40 C/104 F to clean
the front panel, it could cause deformation of
discoloration.
O
O
CAUTIONS
CARE AND MAINTENANCE
Care and maintenance
NOTE: Supply power must be disconnectd before
cleaning the indoor unit.
IMPORTANT: Never use volatile substances(such as
gasoline or alcohol) to clean the panel.
Filter Handle
Cleaning the air filter
OPERATING INSTRUCTIONS
How the air conditioner works
1 hour
1 hour
Set
Temperature
Set
Temperature
Cooling
Heating
SLEEP operation
1 hour
1 hour
SLEEP operation
7 hours timer off
7 hours timer off
AUTO operation
SLEEP operation
DRYING operation
Optimal operation
When you set the air conditioner in AUTO mode, it will
automatically select cooling, heating(cooling/heating
models only), or fan only operation depending on what
temperature you have selected and the room
temperature.
The air conditioner will control room temperature
automatically round the temperature point set by you.
If the AUTO mode is uncomfortable, you can select
desired conditions manually.
When you push SLEEP button on remote controller
during cooling, heating(cooling & heating models only),
or AUTO operation , the air conditioner will
automatically increase (cooling) or decrease (heating)
per hour for the first 2 hours, then hold
steady for the next 5 hours, after that it will switch off.
This characteristic maintains both enery saving and
comfort in night operation.
The fan speed will be automatically controlled under
dry operation.
During the dry operation, if the room temperature is
lower than 10 C(50 F), the compressor stops operation
and restarts until the room temperature is above
12 C(54 F).
To achieve optimal performance, please note the
following:
Adjust the air flow direction correctly so that it is not
directed on people.
Adjust the temperature to achieve the highest comfort
level. Do not adjust the unit to excessive temperature
levels.
Close doors and windows on COOL or HEAT modes,
or performance may be reduced.
Use TIMER ON button on the remote controller to
select a time you want to start your air conditioner.
Do not put any object near air inlet or air outlet, as the
efficiency of the air conditioner may be reduced and
the air conditioner may stop running.
Clean the air filter periodically, otherwise cooling or
heating performance may be reduced.
Do not operate unit with horizontal louvre in closed
position.
O
O
O
O
A clogged air filter reduces the cooling efficiency
of this unit. Please clean the filter every month or
more often if necessary.
1. Push the front panel up straightly, then lift it
upward to an angle of about 20 , do not force to
open it more larger.
2. Use the panel brace to support the front panel
and remain it open as shown in the picture.
3. Take hold of the handle of the air filter and lift it
up slightly to take it out from the filter holder,
then pull it downwards.
O
3. Remove the AIR FILTER from the indoor unit.
Clean the AIR FILTER with a vacuum cleaner
or water, then dry it up in cool place.
.
Push up straightly
Panel
brace
Open the panel to an angle of 20 , lift
the panel brace up to support the panel
and remain it open.
O
PDF created with pdfFactory Pro trial version www.pdffactory.com
The following events may occur during normal operation.
1.
The compressor can't restart for 3 minutes after it stops.
The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in
one of the following three situations and the set temperature has not been reached.
A) When heating has just starting.
B) Defrosting.
C) Low temperature heating.
The indoor or outdoor fan stop running when defrosting (Cooling and heating models only).
Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low
and humidity is high resulting in lower heating efficiency of the air conditioner.
During this condition air conditioner will stop heating operation and start defrosting automatically.
The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and
the amount of frost build up on the outdoor unit.
2.
A white mist may generate due to a large temperature difference between air inlet and air outlet
on COOL mode in an indoor environment that has a high relative humidity.
A white mist may generate due to moisture generated from defrosting process when the air
conditioner restarts in HEAT mode operation after defrosting.
3.
You may hear a low hissing sound when the compressor is running or has just stopped running.
This sound is the sound of the refrigerant flowing or coming to a stop.
You can also hear a low "squeak" sound when the compressor is running or has just stopped
running. This is caused by heat expansion and cold contraction of the plastic parts in the unit
when the temperature is changing.
A noise may be heard due to louver restoring to its original position when power is first turned on.
4.
This is a normal condition when the air conditioner has not been used for a long time or during first
use of the unit.
5.
This is caused by the indoor unit giving off smells permeated from building material, from furniture,
or smoke.
6.
When indoor temperature reaches the temperature setting on air conditioner, the compressor will
stop automatically, and the air conditioner turns to FAN only mode. The compressor will start again
when the indoor temperature rises on COOL mode or falls on HEAT mode (For cooling and heating
models only) to the set point.
Protection of the air conditioner.
Compressor protection
Anti-cold air (Cooling and heating models only)
Defrosting (Cooling and heating models only)
A white mist coming out from the indoor unit
Low noise of the air conditioner
Dust is blown out from the indoor unit.
A peculiar smell comes out from the indoor unit.
The air conditioner turns to FAN only mode from COOL or HEAT (For cooling and
heating models only) mode.
CARE AND MAINTENANCE
Maintenance
Checks before operation
If you plan to idle the unit for a long time, perform
the following:
(1) Operate the fan for about half a day to dry the
inside of the unit.
(2) Stop the air conditioner and disconnect power.
(3) The outdoor unit requires periodic maintenance
and cleaning. Do not attempt to do this yourself.
Contact your dealer or servicer.
Remove the batteries from the remote controller.
Check that the wiring is not broken off or
disconnected.
Check that the air filter is installed.
Check if the air outlet or inlet is blocked after the
air conditioner has not been used for a long time.
Do not touch the metal parts of the unit when
removing the filter. Injuries can occur when
handling sharp metal edges.
Do not use water to clean inside the air conditioner.
Exposure to water can destroy the insulation,
leading to possible electric shock.
When cleaning the unit, first make sure that the
power and circuit breaker are turned off.
Caution
1
2
4. Remove the Air Freshening Filter from its support
frame (on some models).
(The optional filter include :Plasma Dust Collector/
Silver Ion filter /Bio filter /Vitamin C filter/3M air
purifier filter, etc. The removing and installation
methods are slightly different, see the pictures
marked
and
on the left.
Clean the air freshening filter at least once a
month, and replace it every 4-5 months.
Clean it with vacuum cleaner, then dry it in cool
place.
5. Install the air freshening filter back into position.
6. Insert the upper portion of air filter back into the
unit, taking care that the left and right edges line
up correctly and place filter into position. For the
filters with gaps on the edges, please make sure
the filter is completely fixed and locked in the
filter holder.
.
.
1
2
Do not touch the Plasma Dust Collector
Filter within 10 minutes after opening the
front panel, it may cause an electric shock.
PDF created with pdfFactory Pro trial version www.pdffactory.com
Stop the air conditioner immediately if one of the following faults occur. Disconnect the
power and contact the nearest customer service center.
Fuse blows frequently or circuit breaker trips frequently.
Other objects or water penetrate the air conditioner.
The remote controller won't work or works abnormally.
Operaton indicator or other indicators flash rapidly and this flash can not be stopped
by disconnecting the power and then connecting it in again.
Trouble
Malfunctions
Unit does not
start
Unit not cooling
or heating
(Cooling/ heating
models only)
room very well
while air flowing
out from the air
cond tioner
i
Cause
Power cut
Unit may have become unplugged.
Fuse may have blown.
Battery in Remote controller may
have been exhausted.
The time you have set with timer
is incorrect.
Wait for power to be restored.
Check that plug is securely in wall
receptacle.
Replace the fuse.
Replace the battery.
Wait or cancel timer setting.
Set temperature correctly. For
detailed method please refer to
"
"
Using remote control section.
Clean the air filter.
Close the doors or windows.
Clear obstructions away first, then
restart the unit.
Wait.
Inappropriate temperature
setting.
Air filter is blocked.
Doors or Windows are open.
Air inlet or outlet of indoor or
outdoor unit has been blocked.
Compressor 3 minutes
protection has been activated.
If the trouble has not been corrected, please contact a local dealer or the nearest customer
service center. Be sure to inform them of the detailed malfunctions and unit model.
Notes: Do not attempt to repair the unit yourself.
Always consult an authorised service provider.
What should be done?
If one of the malfunction codes appears on the display window: E0, E1, E2, E3, E5,
E6, E7, P0, P1, P2, P3, P4 or P6.
7. Dripping water may generate on the surface of the indoor unit when cooling in a high
relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to
the maximum air outlet position and select HIGH fan speed.
8.
The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit
during heating operation. When the outdoor temperature falls, heat drawn in by the air
conditioner decreases accordingly. At the same time, heat loading of the air conditioner
increases due to larger difference between indoor and outdoor temperature. If a
comfortable temperature can't be achieved by the air conditioner, we suggest you use a
supplementary heating device.
9.
Power failure during operation will stop the unit completely.
For the unit without Auto-restart feature, when the power restores, the OPERATION indicator
on the indoor unit starts flashing. To restart the operation, push the ON/OFF button on the
remote controller. For the unit with Auto-restart feature, when the power restores, the unit
restarts automatically with all the previous settings preserved by the memory function.
For some models, the machine is special designed with Auto-restart function for the open angle
of the horizontal louver.Power failure during operation or pressing the ON/OFF button on the
remote controller will stop the unit completely.When the power restores or pressing the ON/OFF
button on the remote controller again,the unit restarts automatically with all the previous settings
including the open angle of the horizontal louver by the memory function.So we strongly suggest
that the open angle of the horizontal louver should not be set too small,in case the condensed
water forms and drops from the horizontal louver. Press the AUTO/COOL button under the
front panel and the open angle of the horizontal louver will be restored to the standard angle
when the condensed water forms on the horizontal louver.
10. Lightning or a car wireless telephone operating nearby may cause the unit to malfunction.
Disconnect the unit with power and then re-connect the unit with power again. Push the
ON/OFF button on the remote controller to restart operation.
Heating mode (For cooling and heating models only)
Auto-restart function
OPERATION TIPS
PDF created with pdfFactory Pro trial version www.pdffactory.com