INVERTER SPLIT TYPE

ROOM AIR CONDITIONER - CS494U-BPY(UL) 202000192389 20110625 Before using your air conditioner, please read this manual carefully and keep it for future reference. Read This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips. If you review the chart of Troubleshooting Tips first, you may not need to call for service. The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. PDF created with pdfFactory Pro trial version www.pdffactory.com

DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection

of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: A) The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user. B) When buying a new product, the retailer will take back the old product at least free of charge. C) The manufacture will take back the old appliance for disposal at least free of charge to the user. D) As old products contain valuable resources, they can be sold to scrap metal dealers. Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground-water and find their way into the food chain. When using this air conditioner in the European countries, the following informations must be followed: SOCIABLE REMARK SAFETY PRECAUTIONS OPERATING INSTRUCTIONS CARE AND MAINTENANCE OPERATION TIPS TROUBLESHOOTING TIPS Sociable remark.......................................................................................................................2 Warning ..................................................................................................................................3 Caution ...................................................................................................................................4 Parts names ........... ...............................................................................................................5 Special functions .....................................................................................................................6 Operating temperature.............................................................................................................7 Manual operation ....................................................................................................................7 Airflow direction control ..........................................................................................................8 How the air conditioner works ................................................................................................9 Care and maintenance ..........................................................................................................10 Operation tips ............ ..........................................................................................................12 Troubleshooting tips .............................................................................................................14 Contact an authorised service technician for repair or maintenance of this unit. Contact the authinstaller for installation of this unit. Young children should be supervised to ensure that they do not play with the air conditioner. If the power cord is to be replaced, replacement work shall be performed by authorised personnel only. Installation work must be performed in accordance with the national wiring standards by authorised personnel only. This appliance is not intended for use by persons(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. CAUTION PDF created with pdfFactory Pro trial version www.pdffactory.com

To prevent injury to the user or other people and property damage, the following instructions

must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury. Meanings of symbols used in this manual are as shown below. WARNING Always do this. Never do this. CAUTION This symbol indicates the possibility of injury or damage to property. Connect with the power properly. Do not modify power cord length or share the outlet with other appliances Always ensure effective earthing. Disconnect the power if strange sounds, smell, or smoke comes from it. Ventilate room before operating air conditioner if there is a gas leakage from another appliance. Otherwise, it may cause electric shock or fire due to heat generation. excess It may cause electric shock or fire due to heat generation. No earthing may cause electric shock. It may cause fire and electric shock. It may cause explosion, fire and, burns. It may cause electric shock due to heat generation. or fire It may cause electric shock. It may cause failure of machine or electric shock. It contains contaminants and could make you sick. It may cause fire and electric shock. It may cause electric shock or fire. This could damage your health. No installation may cause fire and electric shock. It may cause electric shock. It may cause an explosion or fire. It may cause failure and electric shock. Do not operate or stop the unit by switching on or off the power. Do not operate with wet hands or in damp environment. Do not allow water to run into electric parts. Do not drink water drained from air conditioner. Do not use the power cord close to heating appliances. Do not damage or use an unspecified power cord. Do not direct airflow at room occupants only. Always install circuit breaker and a dedicated power circuit. Do not open the unit during operation. Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc. Do not disassemble or modify unit. WARNING Use the correctly rated breaker or fuse. There is risk of fire or electric shock. SAFETY PRECAUTIONS CAUTION When the air filter is to be removed, do not touch the metal parts of the unit. It may cause an injury. Do not clean unit when power is on as it may cause fire and electric shock, it may cause an injury. Operation with windows opened may cause wetting of indoor and soaking of household furniture. When the unit is to be cleaned, switch off, and turn off the circuit breaker. Stop operation and close the window in storm or hurricane. Use caution when unpacking and installing. Sharp edges could cause injury. Do not clean the air conditioner with water. Water may enter the unit and degrade the insulation. It may cause an electric shock. This could injure the pet or plant. Do not put a pet or house plant where it will be exposed to direct air flow. Ventilate the room well when used together with a stove, etc. An oxygen shortage may occur. Do not use this air cond- itioner to preserve preci- sion devices, food, pets, plants, and art objects. It may cause deterioration of quality, etc. It may cause failure of product or fire. Do not use for special purposes. Turn off the main power switch when not sing the unit for a long time. u If water enters the unit, turn the unit off and disconnect the power , contact a qualified service technician. It may cause failure of appliance or accident. Appearance may be deteriorated due to change of product color or scratching of its surface. Do not place obstacles around air-inlets or inside of air-outlet. Do not use strong detergent such as wax or thinner. Use a soft cloth for cleaning. If bracket is damaged, there is concern of damage due to falling of unit. There is danger of fire or electric shock. Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure. Do not place heavy object on the power cord and take care so that the cord is not compressed. Operation without filters may cause failure. Always insert the filters securely. Clean filter once every two weeks. PDF created with pdfFactory Pro trial version www.pdffactory.com

All the pictures in this manual

are for explanation purpose only. Your air conditioner may be slightly different. The actual shape shall prevail. 1.Displaywindow 2.Frontpanel 3.Panelframe 4.Chassis 5.Airfilter 6.Panelbrace 7.Manualcontrolbutton 8.Connectingpipe 9.Drainhose 10.Remotecontrollerholder 11.Remotecontroller 12. 13. 14. Stop valve Connecting cable Connective pipe Indoor unit Outdoor unit 6 5 7 1 2 3 4 9 8 11 Air outlet Air inlet Air inlet(rear) Air inlet(side) Air outlet 13 14 12 10 Display window Signal receptor DEFROST operation display Displayed when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation. This display is separated into five zones. The zones illuminate based on the compressor current frequency. For example, higher frequency will illuminate more zones. Operation Frequency display Special feature CLEAN AIR display(optional) Displayed when CLEAN AIR feature is activated. TIMER display during Timer operation. Displayed DIGITAL DISPLAY Displays the current setting temperature and malfunction code when the air conditioner is in operation. When SELF CLEAN feature is activated, it displays ,, ,, AUTO operation display Displayed during Auto operation. Improving the quality of indoor air is one of the mission of an air conditioner. This air conditioner is equipped with ionizer or Plasma Dust Collector(Depending on specific onfiguration of the model). With the anions generated by Ionizer, the air circulation of the air conditioner fills the room with refreshing, natural and healthy air. The PlasmaDust Collector generates an high voltage ionization zone, through which the air is converted to plasma. Inside the air most of the dust, smoke, and pollen particles are captured by the electrostatic filter. CLEAN AIR function(on some models) SELF CLEAN function Follow Me function To activate the Follow Me feature, point the remote control towards the unit and press the Follow Me button. The remote display is actual temperature at its location. The remote control will send this signal to the air conditioner every 3 minutes interval until press the Follow Me button again. If the unit does not receive the Follow Me signal during any 7 minute interval, the Follow Me mode will be cancelled automatically. The remote control serves as a remote thermostat allowing for the precise temperature control at its location. Function used after the Shut Down of cooling operation to clean the Evaporator and keep it as fresh for the next operation. This function is only available under COOL(AUTO COOL, FORCED COOL) and DRY mode. Before select the function, it is recomm- ended to run the air conditioner under Cooling operation for about half an hour. Once the Self Clean function is activated, all TIMER setting will be cancelled. During Self Clean operation, when press the SELF CLEAN button on the remote controller again will stop the operation and turn off the unit automatically. Note: The unit will operate as following sequence : FAN ONLY mode at Low fan speed-- Heating operation with LOW fan speed (applicable to cooling & heating modles only) ---FAN ONLY operation--Stop Operation---Turn off. When turns off the unit on COOL, DRY, AUTO (Cool) mode, the air conditioner will continue operating for about 10 minutes (depending on models) at LOW fan speed. This will help to dry up the condensed water inside the evaporator, and prevent the breeding of mildew. Under Anti-mildew operation, do not restart the air conditioner until the unit is completely off. Anti-mildew function (on some models) PDF created with pdfFactory Pro trial version www.pdffactory.com

Airflow direction control

Range Range Vertical louver (three places) Adjust the air flow direction properly otherwise, it might cause discomfort or cause uneven room temperatures. Adjust the horizontal louver using the remote controller. Adjust the vertical louver manually. Perform this function while the unit is in operation. Use the remote controller to adjust the air flow direction. The horizontal louver can be moved at a range of 6 for each press, or swing up and down automatically. Please refer to the REMOTE CONTROLLER OPERATION MANUAL for details. To set the vertical air flow(Up--Down) direction O Move the vertical louver manually to adjust the air flow in the direction you prefer. : Before adjusting the vertical louvers, the supply power must be disconnected. For some models, the vertical louver can be adjusted by using the remote controller. Please refer to the REMOTE CONTROLLER OPERATION MANUAL for details. To set the horizontal air flow direction (left - right) IMPORTANT Do not operate the air conditioner for long periods with the air flow direction set downward in cooling or dehumidifying mode. Otherwise, condensation may occur on the surface of the horizontal louver causing moisture to drop on to the floor or on furnishings. Do not move the horizontal louver manually unless it is necessary. Always use the remote controller. When the air conditioner is started immediately after it was stopped, the horizontal louver might not move for approximately 10 seconds. Open angle of the horizontal louver should not be set too small, as COOLING or HEATING performance may be impaired due to too restricted air flow area. Do not operate unit with horizontal louver in closed position. When the air conditioner is connected to power (initial power), the horizontal louver may generate a sound for 10 seconds, this is a normal operation. CAUTION ,, ,, ,, ,, Manul operation can be used temporarily in case the remote controller is disable or maintenance necessary. OPERATING INSTRUCTIONS Manual operation NOTE: This manual does not include Remote Controller Operations, see the <> packed with the unit for details. Operating temperature Front panel Manual control button Manual control button Side view Mode Temperature Room temperature Outdoor temperature 1. If air conditioner is used outside of the above conditions, certain safety protection features may come into operation and cause the unit to function abnormally. 2. Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the surface of the air conditioner may attract condensation. Please sets the vertical air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode. 3. Optimum performance will be achieved within these operating temperature. For the unit adopts an Electric Heater, when the outside ambient temperature is below 0 C(32 F), we strongly recommend you to keep the machine plugged in order to guarantee it running smoothly. Suggestion: O O CAUTION: For the convenience of operation, the manual control button is designed on the right side of the panel frame. One press of the manual control button will lead to the forced AUTO operation. If press the button twice within five seconds, the unit will operate under forced COOL operation. This button is used for testing purposes only. You had better not choose it. To restore the remote controller operation, use the remote controller directly. CAUTION: 1 2 ● ● NOTE: The unit must be turned off before operating the manual control button. If the unit is operational, continue pressing the manual control button until the unit is off. PDF created with pdfFactory Pro trial version www.pdffactory.com

Cleaning the Grille, Case and Remote Controller

A cloth dampened with cold water may be used on the indoor unit if it is very dirty. Then wipe it with a dry cloth. Do not use a chemically treated cloth or duster to clean the unit. Do not use benzine, thinner, polishing powder, or similar solvents for cleaning. These may cause the plastic surface to crack or deform. Never use water hotter than 40 C/104 F to clean the front panel, it could cause deformation of discoloration. O O CAUTIONS CARE AND MAINTENANCE Care and maintenance NOTE: Supply power must be disconnectd before cleaning the indoor unit. IMPORTANT: Never use volatile substances(such as gasoline or alcohol) to clean the panel. Filter Handle Cleaning the air filter OPERATING INSTRUCTIONS How the air conditioner works 1 hour 1 hour Set Temperature Set Temperature Cooling Heating SLEEP operation 1 hour 1 hour SLEEP operation 7 hours timer off 7 hours timer off AUTO operation SLEEP operation DRYING operation Optimal operation When you set the air conditioner in AUTO mode, it will automatically select cooling, heating(cooling/heating models only), or fan only operation depending on what temperature you have selected and the room temperature. The air conditioner will control room temperature automatically round the temperature point set by you. If the AUTO mode is uncomfortable, you can select desired conditions manually. When you push SLEEP button on remote controller during cooling, heating(cooling & heating models only), or AUTO operation , the air conditioner will automatically increase (cooling) or decrease (heating) per hour for the first 2 hours, then hold steady for the next 5 hours, after that it will switch off. This characteristic maintains both enery saving and comfort in night operation. The fan speed will be automatically controlled under dry operation. During the dry operation, if the room temperature is lower than 10 C(50 F), the compressor stops operation and restarts until the room temperature is above 12 C(54 F). To achieve optimal performance, please note the following: Adjust the air flow direction correctly so that it is not directed on people. Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive temperature levels. Close doors and windows on COOL or HEAT modes, or performance may be reduced. Use TIMER ON button on the remote controller to select a time you want to start your air conditioner. Do not put any object near air inlet or air outlet, as the efficiency of the air conditioner may be reduced and the air conditioner may stop running. Clean the air filter periodically, otherwise cooling or heating performance may be reduced. Do not operate unit with horizontal louvre in closed position. O O O O A clogged air filter reduces the cooling efficiency of this unit. Please clean the filter every month or more often if necessary. 1. Push the front panel up straightly, then lift it upward to an angle of about 20 , do not force to open it more larger. 2. Use the panel brace to support the front panel and remain it open as shown in the picture. 3. Take hold of the handle of the air filter and lift it up slightly to take it out from the filter holder, then pull it downwards. O 3. Remove the AIR FILTER from the indoor unit. Clean the AIR FILTER with a vacuum cleaner or water, then dry it up in cool place. . Push up straightly Panel brace Open the panel to an angle of 20 , lift the panel brace up to support the panel and remain it open. O PDF created with pdfFactory Pro trial version www.pdffactory.com

The following events may occur during normal operation.

1. The compressor can't restart for 3 minutes after it stops. The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached. A) When heating has just starting. B) Defrosting. C) Low temperature heating. The indoor or outdoor fan stop running when defrosting (Cooling and heating models only). Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low and humidity is high resulting in lower heating efficiency of the air conditioner. During this condition air conditioner will stop heating operation and start defrosting automatically. The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and the amount of frost build up on the outdoor unit. 2. A white mist may generate due to a large temperature difference between air inlet and air outlet on COOL mode in an indoor environment that has a high relative humidity. A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting. 3. You may hear a low hissing sound when the compressor is running or has just stopped running. This sound is the sound of the refrigerant flowing or coming to a stop. You can also hear a low "squeak" sound when the compressor is running or has just stopped running. This is caused by heat expansion and cold contraction of the plastic parts in the unit when the temperature is changing. A noise may be heard due to louver restoring to its original position when power is first turned on. 4. This is a normal condition when the air conditioner has not been used for a long time or during first use of the unit. 5. This is caused by the indoor unit giving off smells permeated from building material, from furniture, or smoke. 6. When indoor temperature reaches the temperature setting on air conditioner, the compressor will stop automatically, and the air conditioner turns to FAN only mode. The compressor will start again when the indoor temperature rises on COOL mode or falls on HEAT mode (For cooling and heating models only) to the set point. Protection of the air conditioner. Compressor protection Anti-cold air (Cooling and heating models only) Defrosting (Cooling and heating models only) A white mist coming out from the indoor unit Low noise of the air conditioner Dust is blown out from the indoor unit. A peculiar smell comes out from the indoor unit. The air conditioner turns to FAN only mode from COOL or HEAT (For cooling and heating models only) mode. CARE AND MAINTENANCE Maintenance Checks before operation If you plan to idle the unit for a long time, perform the following: (1) Operate the fan for about half a day to dry the inside of the unit. (2) Stop the air conditioner and disconnect power. (3) The outdoor unit requires periodic maintenance and cleaning. Do not attempt to do this yourself. Contact your dealer or servicer. Remove the batteries from the remote controller. Check that the wiring is not broken off or disconnected. Check that the air filter is installed. Check if the air outlet or inlet is blocked after the air conditioner has not been used for a long time. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock. When cleaning the unit, first make sure that the power and circuit breaker are turned off. Caution 1 2 4. Remove the Air Freshening Filter from its support frame (on some models). (The optional filter include :Plasma Dust Collector/ Silver Ion filter /Bio filter /Vitamin C filter/3M air purifier filter, etc. The removing and installation methods are slightly different, see the pictures marked and on the left. Clean the air freshening filter at least once a month, and replace it every 4-5 months. Clean it with vacuum cleaner, then dry it in cool place. 5. Install the air freshening filter back into position. 6. Insert the upper portion of air filter back into the unit, taking care that the left and right edges line up correctly and place filter into position. For the filters with gaps on the edges, please make sure the filter is completely fixed and locked in the filter holder. . . 1 2 Do not touch the Plasma Dust Collector Filter within 10 minutes after opening the front panel, it may cause an electric shock. PDF created with pdfFactory Pro trial version www.pdffactory.com

Stop the air conditioner immediately if one of the following faults occur. Disconnect the

power and contact the nearest customer service center. Fuse blows frequently or circuit breaker trips frequently. Other objects or water penetrate the air conditioner. The remote controller won't work or works abnormally. Operaton indicator or other indicators flash rapidly and this flash can not be stopped by disconnecting the power and then connecting it in again. Trouble Malfunctions Unit does not start Unit not cooling or heating (Cooling/ heating models only) room very well while air flowing out from the air cond tioner i Cause Power cut Unit may have become unplugged. Fuse may have blown. Battery in Remote controller may have been exhausted. The time you have set with timer is incorrect. Wait for power to be restored. Check that plug is securely in wall receptacle. Replace the fuse. Replace the battery. Wait or cancel timer setting. Set temperature correctly. For detailed method please refer to " " Using remote control section. Clean the air filter. Close the doors or windows. Clear obstructions away first, then restart the unit. Wait. Inappropriate temperature setting. Air filter is blocked. Doors or Windows are open. Air inlet or outlet of indoor or outdoor unit has been blocked. Compressor 3 minutes protection has been activated. If the trouble has not been corrected, please contact a local dealer or the nearest customer service center. Be sure to inform them of the detailed malfunctions and unit model. Notes: Do not attempt to repair the unit yourself. Always consult an authorised service provider. What should be done? If one of the malfunction codes appears on the display window: E0, E1, E2, E3, E5, E6, E7, P0, P1, P2, P3, P4 or P6. 7. Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed. 8. The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating operation. When the outdoor temperature falls, heat drawn in by the air conditioner decreases accordingly. At the same time, heat loading of the air conditioner increases due to larger difference between indoor and outdoor temperature. If a comfortable temperature can't be achieved by the air conditioner, we suggest you use a supplementary heating device. 9. Power failure during operation will stop the unit completely. For the unit without Auto-restart feature, when the power restores, the OPERATION indicator on the indoor unit starts flashing. To restart the operation, push the ON/OFF button on the remote controller. For the unit with Auto-restart feature, when the power restores, the unit restarts automatically with all the previous settings preserved by the memory function. For some models, the machine is special designed with Auto-restart function for the open angle of the horizontal louver.Power failure during operation or pressing the ON/OFF button on the remote controller will stop the unit completely.When the power restores or pressing the ON/OFF button on the remote controller again,the unit restarts automatically with all the previous settings including the open angle of the horizontal louver by the memory function.So we strongly suggest that the open angle of the horizontal louver should not be set too small,in case the condensed water forms and drops from the horizontal louver. Press the AUTO/COOL button under the front panel and the open angle of the horizontal louver will be restored to the standard angle when the condensed water forms on the horizontal louver. 10. Lightning or a car wireless telephone operating nearby may cause the unit to malfunction. Disconnect the unit with power and then re-connect the unit with power again. Push the ON/OFF button on the remote controller to restart operation. Heating mode (For cooling and heating models only) Auto-restart function OPERATION TIPS PDF created with pdfFactory Pro trial version www.pdffactory.com