Aethra ISDN71 Technical Specifications
Read Online
Read the Aethra ISDN71 Technical Specifications online using the built-in PDF viewer.
Text of the manual
The D2071 multi-interface tester extends its action field by adding the
capability to investigate the ISDN world. This is achieved with the ISDN71
module that integrates the Aethra long-time experience on ISDN in the new
generation modular tester.
The card is able to characterize the S/T interface completely, allowing a full
control of the communications occurring between TE and NT; the devices
themselves can be checked as well.
The available operating modes permit the simulation of both the Terminal
Equipment and the Network Termination; in addition to these ones, the
instrument can carry out a high impedance monitor on the S/T bus.
On the other hand, the background monitor allows the user to execute a
test and concurrently capture the D-channel signalling protocol. The
acquired trace can be immediately analyzed on the screen or uploaded to
a PC for further analysis.
The SMART STATUSTM feature provides the user of some immediate
information about the connection showing the ISDN Layer 1,2 and 3 status
in a detailed and clear way. Moreover, all B-channel relevant data like loop,
audio, called number, etc., are grouped in a specific page.
The tests dealing with the call, BER, X.25, loop-box, automatic check of the
access, help and lead the technician to a correct installation and a quick
troubleshooting.
The two hardware options (WT2071 and D1029) enrich the capabilities of
the user as they offer him further tests and simulations concerning the S/T
bus cabling and the check of the Terminal Equipment in standard and
emergency mode.
ISDN CARD FOR MULTI INTERFACE TESTER D2071
FEATURES AT A GLANCE
ISDN BRI S/T bus fully characterized
Automatic tests for immediate check of the ISDN line
In-depth BER test for line quality check
Status for D/B channel activity, INFOs
and ISDN layers
Three operating modes for monitoring and
simulations
”Live” capture and analysis of D-channel signalling
protocol
Trace file uploaded to PC both during capture and
off-line
Modular philosophy
All you need for measurements dealing with
ISDN S/T bus interface
Increased capabilities
High impedance monitor in addition to back-
ground monitor
Hardware options
Two chances to enlarge your action field,
ISDN71 MODULE
S/T BUS CABLE CHECK [WT2071 OPTION]
• Features
Extraneous voltage
Crossed wires
Short circuit
Open wires
Termination resistances, value in Ohm
• Results
Textual and graphical report of the state of the S/T Bus
CONNECTORS
• ISDN BRI S/T
4 wires RJ45
• Main unit
68 wires
ENVIRONMENTAL CHARACTERISTICS
• Dimension
Weight
≈65 gr.
Dimensions (mm)
54 (w) x 118 (l) x 33 (d)
• Power
Power supply from the main unit
• Temperature
Storage/Transport
-40oC to +70 oC
Operating, nominal
-5oC to +45 oC
Operating, limits
-10oC to +55 oC
• Humidity, non-condensing
≤93% RH @ 40 oC
≤70% RH @ 55 oC
• User's Safety Aspects
EN 61010-1,EN 60950,EN 41003
• EMC Aspects
EN 55022, EN 55024,
EN 61000-3-2 / -3-3
OPTIONS
• 1WT2071
S/T Bus wiring test
• 2D1029
Phantom power supplier on
S/T Bus
TELECOM INTERFACES
• ISDN Basic Rate access
S/T
ITU-T (CCITT) Rec. I.430
ETS 300 012
OPERATING MODES
• TE-S
• MON-S
• NT-S
• S/T Bus wiring test
(option1)
SMART STATUSTM
• Status levels ISDN 1,2 and 3
• D/B channel activity
• INFOs
• Pulse amplitude
• Battery status
BIT ERROR RATE TEST
• G.821 statistics
ES, SES, US, DM, PASS/FAIL
• Pseudo-Random bit sequence
User definable 211-1, 215-1,
223-1, 16 bits octet
• Error Injection
Manual, Single, Automatic
AUTOMATIC ACCESS TEST
• Fully automated Access test
• Supplementary services automatic test
• Programmable test sequence
• X.25 on D-Channel check
PROTOCOLS SUPPORTED
• Simulation mode
EDSS-1, Q.SIG, 1TR6, TN1R6®,
VN4, X.25 over D channel,
CorNet®-N, -T
• Monitor mode
EDSS-1, Q.SIG, 1TR6, TN1R6®,
VN4, X.25, CorNet®-N, -T
• Other protocols available
DMS100, NI1, 5ESS
TECHNICAL SPECIFICATIONS
Aethra, the Aethra logo and ISDN71 are registered trademarks of Aethra SpA in Italy and in other Countries. All other company and product names may be registered trademarks or trademarks of their respective
owners. All information provided by Aethra SpA in this datasheet is believed to be accurate. Aethra SpA reserves the right to discontinue and change specifications and prices at any time without notice. Copyright
© 2005 Aethra SpA - All rights reserved. For further details about technical specifications please see “Products” on our website: www.aethra.com.
Code 071075004GB Rev. 4 (02/04)
Headquarters
AETHRA® SpA
via Matteo Ricci, 10
60020 Ancona (Italy)
Telephone +39.071.218981
Fax
+39.071.887077
Video 1
+39.071.2189160
Video 2
+39.071.2189701
Email: [email protected]
www.aethra.com
Aethra Offices
Milan Bologna Rome Palermo
Paris Madrid London Beijing
Aethra Companies
Aethra Inc. - Miami (USA)
Aethra Ameris - São Paulo (Brazil)
Aethra Mexico - MexicoCity (Mexico)
Aethra Technology - Shenzen (China)
Aethra Asia - Hong Kong (China)
Code 071072013GB Rev. 0 (03/05)