LightSYS User Manual

Page 2 Summary of Keypad Main User Commands Full Set Code > Part Set Code > System Unset Code> Silence an Alarm Code> Partition Full Set Code > > Partition No. > Partition Part Set Code > > Partition No. > Partition Unset Code> > Partition No. > Duress Unset Duress Code > Panic Alarm Pressing simultaneously for 2 seconds Fire Alarm Pressing simultaneously for 2 seconds Medical Alarm Pressing simultaneously for 2 seconds Omit Zones Code > [Zone No.] Activate Output [Code] [Activities] [Output Control] Define Follow-Me >[Code] [Follow Me] [Define] View Fault [Code] [View] [Fault] View Zone Status [Code] [View] [Zone Status] View Partition Status Code > View Event Log [Code] [Event Log] Keypad Chime On/Off [Code] [Activities] [Keypad sound] [Chime] Edit User Code [Code] [Codes/Tags] [Define] Zone Testing (Walk Test) [Code] [Maintenance] [Walk Test]

LightSYS User Manual

Table of Contents Summary of Keypad Main User Commands ........................................................... 2 Chapter 1 Mastering Your System ........................................................................... 5 Introduction ........................................................................................................................................... 5 Main System Capabilities ................................................................................................................... 5 LightSYS Architecture ......................................................................................................................... 6 User Operating Tools .......................................................................................................................... 7 System Monitoring ............................................................................................................................... 8 Report to Alarm Receiving Center ........................................................................................... 8 Follow Me Messaging ................................................................................................................ 8 Keypad Indication ................................................................................................................................ 9 Keypad LCD Icons ..................................................................................................................... 9 LCD Status Display .................................................................................................................... 9 LCD Blank Display ................................................................................................................... 10 System Tones .................................................................................................................................... 10 Chapter 2 Setting and Unsetting ............................................................................ 13 Setting your system ........................................................................................................................... 13 Before setting the system: ...................................................................................................... 13 Full setting ................................................................................................................................. 14 Part setting ................................................................................................................................ 14 Partition setting ......................................................................................................................... 15 Group Setting ............................................................................................................................ 16 Setting With Faults in the System .......................................................................................... 17 Keyswitch Setting ..................................................................................................................... 17 Setting in Blank Display Mode ................................................................................................ 17 Unsetting your system ...................................................................................................................... 18 Full Unsetting ............................................................................................................................ 18 Partition Unsetting .................................................................................................................... 18 Unsetting after an Alarm ......................................................................................................... 19 Resetting after an alarm .......................................................................................................... 20 Duress Unsetting ...................................................................................................................... 21 Disabling a Fire Alarm (Switch Auxiliary) .............................................................................. 21 Additional Set/Unset Capabilities .................................................................................................... 22 Automatic Set/Unset ................................................................................................................ 22 Set /Unset from your Wireless Keyfob .................................................................................. 22 Remote Set/Unset Using SMS ............................................................................................... 22 Remote Set/Unset Using a Phone ......................................................................................... 23 Emergency Alarms ............................................................................................................................ 24 Chapter 3 User Functions and Settings ................................................................ 25 User Codes......................................................................................................................................... 25 Authority Levels ........................................................................................................................ 26 Setting / Changing User Codes .............................................................................................. 27 Deleting User Codes ................................................................................................................ 27 User Code Labels .................................................................................................................... 28 Proximity Tags ................................................................................................................................... 28

LightSYS User Manual

Page 4 Adding a New Proximity Tag .................................................................................................. 29 Deleting a Proximity Tag ......................................................................................................... 29 Setting and Changing System Time and Date............................................................................... 30 Setting Follow Me Destinations ....................................................................................................... 31 Omitting zones ................................................................................................................................... 32 Scheduling Weekly Programs .......................................................................................................... 33 Automatic Setting/Unsetting ................................................................................................... 33 Automated Output Operation .................................................................................................. 34 User Limitation Program ......................................................................................................... 34 Quick Activation/Deactivation of a Weekly Program ........................................................... 34 Macro Keys......................................................................................................................................... 35 Programming Macro Keys ...................................................................................................... 35 Activating a Macro.................................................................................................................... 36 Parking Control with LightSYS Gate Control Keyfobs .................................................................. 36 Assign New Keyfob .................................................................................................................. 36 Delete a keyfob......................................................................................................................... 37 Delete All keyfobs .................................................................................................................... 37 Change keyfob buttons that controls the outputs ................................................................ 37 Complete List of User Functions ..................................................................................................... 38 Appendix A – System Faults .................................................................................. 44 Appendix B – Glossary ........................................................................................... 45 Appendix C – Scheduling Tables ........................................................................... 47 Appendix D – SMS Operation ................................................................................. 48 Appendix E – System Testing and Maintenance .................................................. 49

Mastering Your System

Page 5 LightSYS User Manual Chapter 1 Mastering Your System Introduction Congratulations on your purchase of RISCO Group's LightSYS Security System. The LightSYS has been specifically designed to meet a wide range of security needs for residential and commercial applications. LightSYS is designed to recognize abnormal conditions and inform the system of the status of any protected door, window, hallway, room, or area. It supports the capabilities of communicating with a Central Alarm Receiving Center or to your mobile phone using friendly and easy to understand verbal messages as well as SMS or E-mail messages The LightSYS contains a variety of programming features. Ask your engineer which features have been programmed for your system. This manual describes how to operate your system. It will guide you through programming instructions for main system features as well as basic setting and unsetting commands for the system Main System Capabilities Up to 32 sensor devices 16 User codes + Grand Master code 4 authority levels for different system users Optional user proximity tag to be used instead of a code Up to 4 partitions 4 wired / wireless keypads Up to 4 sounders Up to 16 full control remote controls Up to 200 gate control remote controls 500 Events Log 16 Follow Me destinations Up to 14 outputs X-10 support for home automation 4 automatic scheduling programs

Other Security System Manuals