ACCESS CONTROLLER WITH INTEGRATED

PROXIMITY & PIN READER FIRMWARE VERSION 119.0 Installation Manual ...

The PR302 controller is dedicated for use in Access Control and Time & Attendance systems. It may be configured to perform both function

simultaneously or exclusively. PR302 has a built-in proximity reader, 12 digit keypad and three LEDs. Controller offers three inputs, one relay output and two transistor outputs. Inputs and ...

be manually downloaded to PC database or will be downloaded automatically anytime the Monitoring window of PR Master program is

activated. Note: The main advantage of networked system equipped with CPR is that events which have been occurred on controllers are instantly transferred to remote “secure” buffer in CPR and that CPR continuously ...

The lift control module, floors 1-8.

9 XM-8 module The lift control module, floors 9-16. 10 Reserved 11 Reserved 12 Reserved 13 Reserved 14 Reserved 15 Reserved Note: If controller is configured for operation with remote Wiegand type reader instead of PRT terminal no XM modules nor PSAM-1 can be connected to ...

Selects Predefined T&A Mode –

Momentary Type Selection Input is dedicated to be connected to button which when pressed will turn controller to specified T&A Mode. The T&A mode which will be set after input is triggered is declared by installer for each input line individually. The new T&A Mode is active till nearest user identification, if du ...

Signalization of the PREALARM, DOOR ALARM and FORCED ENTRY disappears automatically after 3 minutes or can be switched off

earlier by using any valid identifier (Card/PIN) registered in system. Alarm on controller can also be cleared remotely from PC. When the [ALARM Output] has been programmed to signalize more than one alarm condition, only t ...

automatically disarm adequate alarm zone. The access to premises/zone can be temporary blocked when controller stay in OFF mode, this

can be achieved by option Access disabled in OFF mode. An ON/OFF mode of controller can be controlled in few listed below ways: • manually by SWITCHER or MASTER user, • by external input line configured as ON ...

Door Mode determines how the controller will energize and de-energize door lock. Door lock can be set to few listed below modes of

operation: Door Mode Description Normal Door lock is activated after controller decide to grant access. Unlocked Door lock is continuously energized, door can be opened by any unauthorized person. Conditi ...

by adequate Time Schedule (T&A Mode Schedule),

• by manual command entered from controller's keypad, • by activation of input line. If option Terminals ID=0 and ID=1 have the same T&A Mode is active events registered on terminal ID=0 have the same T&A status a as events registered on terminal ID=1 (no matter if event was registered on t ...

Optical (LED) signalization

Controller offer three LEDs marked as ON/OFF, OPEN and SYSTEM. An ON/OFF led is a bicolor type and may be set to green or red. When set to green it signalize that controller is in ON mode, when is set to red it signalize that controller is in OFF mode. Led OPEN (green) signalize that relay output is activated what u ...