SYSTEM OUTLINE & COMPONENTS
DE-UR is an adaptor that can add a door station, audio or PanTilt video to TD Phone Selective Call Intercom.
IF-DA
@-
IF-DA
5(+,-,D and two C)
to TD-H(or TD-Z) stations
A position, preset
Set to B position
Package contents
Packet of screws
Installation & Operation Manual
*TD-H or TD-Z system is
powered by a PS-12A (PS-
12C), which should be located
in the middle point of cable run.
Install a DE-UR(s) near the
power supply.
Components available
* Intercoms
TD-H Series: TD-3H/B, TD-6H/B, TD-I 2H/B & TD-24H/B. (TD-H/A Series also)
TD-2 Series: TD-6Z/A & TD-I2Z/A loop-wired. Audio door station only.
0 Intercom
0 Audio door stations
0 Video door stations
TD-6HIB
TD-12UA
IF-DA
Others : IE-FY (not available in USA)
Others : MY-DG, MY-EA
It can be a combination of MY-CA
(in MYW-CA enclosure) and IF-DA.
NAMES AND FEATURES
Call tone selector
For TD-H to have 2 door stations, DE-UR employs a
switch (preset to A) to change slow intermittent tone to
faster intermittent tone.
Features
* Surface-mount with 83.5mm, 3-5/16" guide.
* Call tone modulating circuits, 2-1/2-sec. timed.
* Powered by using system's PS-I 2N12C power supply.
* Includes door release control terminals.
Front case
screw
- 1 -
PRECAUTIONS ON INSTALLATION & WIRING
A
CAUTION
* Do not connect any terminal on any unit to AC power lines.
* Unplug all power supplies while making wiring connections on any audio and video equipment.
* DE-UR is an adaptor for indoor installation only. Follow precautions as stated in the Manuals packed with
* Locate DE-UR unit(s) closely to power supply PS-12A (PS-12C) of TD-H or TD-Z system, so as to be fed DC12V
* Wiring to EL-9S door release must run in a separate jacketed cable and apart from intercom wiring.
TD-H and MY-CU monitor.
from it.
Before installing DE-UR, the contents of this Manual must be thoroughly read and understood.
WIRING
Terminal block layout
+, - :
1, 2 :
C :
D :
EL, EL:
12V DC power
Door station connection
Selective communication from TD-H/TD-Z masters
Call-in tone to TD-H masters (or TD-Z)
Dry closure contact for door release
DE-UR & power supp.: IocaLJn
It is suggested to mount a DE-UR unit(s) in a recessed area, together with power supply PS-12A (PS-12C) and
video adaptor, etc. Select a location that allows limited access only by qualified personnel, and is dust-free
environment possible.
Audio door station
k
EL-SS,
AC trans.
AC
PanTilt video door station
/-
4 to TD-H
AC trans
AC
AC
- 2 -
2 PanTilt doors plus 1 camera
6
to MYH-CU
(r
5 to TD-H
-UR
PS-12Aor
PS-12c
camera
AC
AC
AC trans
1. One audio IE/IF Series
T
Rp
2. Two audio IE/IF Series
DE-UR
DE-UR
IF-DA
IF-DA
1
2
DE-UR
IF-DA
'I
no
no 7
PS-12A
(PS-12C)
4 wires to
(max. 12)
' to TD-H(TD-2)
PS-12A
(PS-12C)
5 wires to
to TD-H(TD-2)
4. Two PanTilt MY Series
3. One PanTilt MY Series (plus one audio)
MY-CU
MY-DC
to PanTilt 1
to PanTilt 2
TO MY-Ck
(camera
PS-18D
2
7
DE-UR
DE-UR
-0 IF-0
1-
(door2) :E
I
I
DE-UR
PS-12A
DE-UR
TD-H
(max. 12)
4
I
to TD-
(for MY-DC)
(IF-DA)
- 3 -
DE-UR chassis, after separated, mounts with
83.5mm, 3 4 1 6" guide.
DE-UR
DE-UR
1. Opening the cover, loosen the bottom screw.
2. Lift front case off the prongs of chassis, and
disconnect DE-UR.
3. Mount the chassis to wall or board at 2 points.
4. Make wire terminations for each door station,
TD-H station, and PS-l2A(12C) power supply.
5. Reconnect and mount DE-UR front case to
chassis.
Diameter
Distance
AWG
Distance
Pronas
0.65mm
0.8mm
1 .Omm
1 Om
15m
20m
22AWG
20AWG
18AWG
30'
50'
65'
3
-~
_L
83.5mm
(3-5/16")
-Chassis
Distance
S P E C I F I CAT1 0
N S
* Power source:
* Current consumption:
120mA max.
* Call tone:
DC 12V, supplied by a power supply PS-12A (PS-12C) of TD-H (TD-Z) system.
Intermittent tremolo, 2-1/2-timed
150m
I
230m
I
360m
* Wiring:
Distance
I To audio IE/IF door
I 2 conductors laarallel)
I
500'
I
750'
I
1,200'
1 To TD-H/B stations
1 4 conductors (D, C and + , -)
1
* Wiring distance:
From DE-UR to door station
I Diameter
1
0.65mm I
0.8mm
I
1 .Omm
I
l
l
1
}to TD-H
* DE-UR EL, EL terminals capacity:
* Dimensions: (H x W x D) 160 x 150 x 45 (mm). 6-1/4"H x 6"W x 1-3/4"D
* Weight:
DC 30V, 1A or AC 30V, 1A.
320g (0.71 Ibs.) approx.
-4- 4
4
WARRANTY
4
%
4
4
$
4
4
4
4
4444444444444444444444444444444444444444444444444444444444444~
Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of one
year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which
examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final decision
whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty.
This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation of
instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover
batteries or damage caused by batteries used in connection with the product.
This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone.
Aiphone will not be responsible for any costs incurred involving on site service calls.
Aiphone Co., Ltd., Nagoya, Japan
Aiphone Corporation, Bellevue, WA, USA
DE-UR-I(E) 0595E
T
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
44
g
KlMU$fiOSKC
HOME BUSINESS INDUSTRY
Printed in Japan (E)
- 4 -