- INSTRUCTIONS -

The LE-SSV is a 2-gang stainless steel vandal proof and weather resistant sub station designed for use with the systems listed above. It is constructed of 12 gauge stainless steel and has a stand alone color camera built in. The unit either flush mounts into a 2-gang box, or surface mounts using the SBX-2G. Each unit includes a 12V DC power transformer for the camera, tamper proof screws, and a tool for installation. Vandal Resistant Sub Station with built in Color Pinhole Camera for use with AP-M, LAF-C, LDF-C, LEF, LEM, MP-S Systems Page 1 Transparent corner shadowing on the picture is normal. Front View Back View The view achieved if the subject is 20" from the camera is: 18" Vertically and 26½” Horizontally Speaker Camera Call button 45cm 18” 67cm 26½” 50cm / 20” 50cm 20” INSTALLATION: 1. For flush mounting, install sub station in standard 2-gang electrical box with minimum 2-1/2" depth. 2. For surface mounting, use the SBX-2G surface mount enclosure (sold separately). 3. Only the 12V DC power supply included should be used to power the LE-SSV camera. 4. IMPORTANT! These units are designed for use in normal weather conditions, and to allow drainage and evaporation of moisture that naturally gets into the unit. Do not apply caulking or silicone sealant around the unit when installing, and do not use weather stripping around the perimeter of the box when mounting. If sealing the unit is required, the bottom must remain unsealed. Sealing the unit will prevent or inhibit moisture from dissipating from inside the unit, which may cause corrosion or deterioration of the internal components over time. 1011

Jumper Blue & Black

wires together + - 1 2 ~ 10 E + - Red Blk* Blu Red Blk* Blu LEF, LAF/LDF Master Station* LE-SSV PS-1225UL * In a single master LEF system only, 2 conductors homerun can be used with the BLK and BLU wires tied together and "E" and "-" jumpered at the master. LEF SYSTEM: LE-SSV + - 1 E + - Red Blk Blu LEM Master LE-SSV *LEM-1 or LEM-3: Use SKK-620 (6V DC) LEM-1DL: Use PT-1210N (or any source providing 12-16V AC or 12-24V DC) Jumper Blue & Black wires together Power Source* LEM SYSTEM: 12V DC power input for camera (Red - Must use supplied transformer) Video output to monitor or CCTV system (Yellow) 12V DC power input for camera (Red - Must use supplied transformer) Video output to monitor or CCTV system (Yellow) 12V DC power input for camera (Red - must use supplied transformer) Video output to monitor or CCTV system (Yellow) 12V DC power input for camera (Red - must use supplied transformer) Video output to monitor or CCTV system (Yellow) 12V DC power input for camera (Red - must use supplied transformer) Video output to monitor or CCTV system (Yellow) 12V DC power input for camera (Red - Must use supplied transformer) Video output to monitor or CCTV system (Yellow)

Toll Free Technical Support:

1-800-692-0200 E-mail [email protected] LE-SSV Instr. 1011JD SPECIFICATIONS: Audio Power Source: Supplied by master station Speaker: 20 ohms, 4W, 2" diameter, water proof and puncture resistant, 2.4 oz. magnet Call Button: SPST call button, momentary activation. Limited stop button Call Annunciation: Call tone rings at master as long as button is held down. LED will remain lit for approx. 20 seconds (LEF, LEM-3, MP-3S, AP-5/10M only). Call tone only on LEM-1DL, LEM-1, and MP-1S. Communication: Hands free at sub. Master is push-to-talk, release-to-listen. CCTV Camera Output: 75 Ohm, 1Vp-p, NTSC, DC-coupled Iris Control: Auto Minimum Illumination: 1.0 lux Camera image sensor: 1/3" CCD Focal Length: 4.3mm Cone Pinhole Lens (78°) Effective Pixels: 510(H) x 492(V) NTSC Camera Power Source: 12V DC, 100mA (via included power supply) MTBF: (Mean Time Before Failure) 80,000 Hours Faceplate: 12 gauge stainless steel Mounting: Flush mount into a 2-gang box (minimum 2-½” depth) or surface mount into SBX-2G (sold separately) Tamper proof screws included (6x32 for use with flush 2-gang box) with T-10 TORX bit When using SBX-2G, use the hardware included with that unit. Terminations: Color-coded prewired pigtails. Red wire = “1"; Black wire = “E”; Blue wire = negative; Red connector = 12VDC power; Yellow connector = 75 Ohm / 1Vp-p video output (BNC). Operating Temperature: 14 F ~ 140°F (-10°C ~ 60°C) Audio Wiring: 2 conductors in a 1-master LEF, MP-S, or AP-M system. 3 conductors in a multi-master LEF system. Shielded cable is recommended. Use Aiphone #822202 for LEM or MP-S. Use #822202 or #822203 for LEF. Use #832202 for AP-M systems. Audio Wiring Distance: See system that unit is being used with for distance specifications. Video Wiring: Independent BNC connection from substation pigtail to destination video device. Dimensions (H x W x D): LE-SSV alone: 4-11/16" x 4-11/16" x 2" With SBX-2G: 4-3/4" x 4-7/8" x 3-5/8" (Top) 2-3/8" (Bottom) Aiphone Communication Systems 1700 130th Ave. N.E. Bellevue, WA 98005 (425) 455-0510 FAX (425) 455-0071 Color Camera Call Button Yellow BNC connector for video output Red: # terminal of Master Black: E of Master Blue:- (Neg.) of Master Speaker LE-SSV BACK VIEW: Red connector for 12V DC camera power input (from included power supply) Power supply dimensions: 1-⅝" W x 2-¼” H x 1-⅝” D 6' DC cord. NOTE: If using fiber optic interface, the video input on the IFS VIC-5211 is not compatible with the LE-SSV camera. The VIC-5211 can be used for audio only, with a separate fiber module required for video. Intercom wiring must be run at least 20" away from any AC wiring, fluorescent lighting, dimmer switches, or any other electronic device that may cause interference.

Other Security System Manuals