Apera LabSen 252 Manuals
1 pdf manual(s) Apera LabSen 252 for free download (Document Types: Operation & user’s manual)
Apera LabSen 252 Operation & user’s manual [PDF] (2 pages)
- Identifier: id-2030526
- Brand: Apera
- Device: Apera LabSen 252 Measuring Instruments
- Type: Operation & user’s manual, PDF
- Key Aspects: Performance Optimization Tips, Troubleshooting Information, Component Longevity Optimization
- UPD Date: 18.04.2026
- Source File: 2257332.pdf
- Pages: 2
- Description: Product usage manual for the Apera LabSen 252.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
LabSen 252 Glass Spear pH Electrode User Manual LabSen electrochemical sensors are premium pH electrode with manufacturing technology and key components imported from Switzerland. LabSen252 adopts spear type glass membrane, which can easily pierce solid or semi-solid medium. This electrode is suitable for cheese, meat, fruit and vegetable testing. This probe has following features: ⚫ Impact-resist membrane, there is no danger of electrode breakage during normal use. ⚫ Blue gel inner solution, does not flow and will not cause bubble. ⚫ Maintenance-free polymer electrolyte, non-diaphragm structure. ⚫ Long life reference system, has better stability and service life. 1 Technical Data Measuring Range (0 ~ 14) pH Electrolyte Polymer Temperature Range (0 ~ 80) °C Soaking Solution 3M KCl Shaft Material Lead-free Glass Electrode Dimension Electrode (Ø12×100) mm Measuring Tip (Ø6×35) mm Membrane Shape Tapered Reference Long Life Connector S7 Junction Ceramic+Single Pore Cable S7-BNC / Ø3×1m 2 Usage and Maintenance 2.1 Connect electrode to S7-BNC cable, and then connect BNC plug to the input on the pH meter. 2.2 When measuring, please unscrew the bottle cap, pull out the electrode and rinse it with deionized water. After using, please put the electrode back into the bottle and screw tight the cap. 2.3 After long time exposure in air, Polymer electrolyte will cause shrinkage. It will not happen in measurement status. The electrode must be soaked in 3M KCl solution for storage. After long time soaking, there will be some floccules dissolving out from 3M KCl solution, this is normal phenomenon. Before pulling out or putting back the electrode, make sure to fully loosen the blue cap on the storage sleeve so that the electrode can move in and out smoothly.
Similar Manuals in the Measuring Instruments Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
FILL-RITE FR1118-A10 |
#SVL225: FR1118-A10 Measuring Instruments Operation & user’s manual |
6 | 783 | 181 | 06-06-2026 | view all manuals | |
Radio Shack TRS-80 |
#STYY18: TRS-80 Desktop Technical manual |
42 | 480 | 116 | 29-03-2026 | view all manuals | |
VOLTCRAFT CO-700 |
#1SW11A: CO-700 Measuring Instruments Operating instructions manual |
8 | 780 | 156 | 06-04-2026 | view all manuals | |
Honeywell AutoSet 1500 |
PDF User Manual (@RQCMS2), Honeywell AutoSet 1500 Measuring Instruments (08-04-2026) |
63 | 1032 | 176 | 08-04-2026 | view all manuals | |
Emerson Rosemount 5900 |
PDF User Manual (@L11U91), Emerson Rosemount 5900 Measuring Instruments (22-07-2026) |
62 | 1400 | 238 | 22-07-2026 | view all manuals | |
patura P4500 |
#YKX148: P4500 Power Supply Operation & user’s manual |
76 | 444 | 76 | 30-03-2026 | view all manuals |