Apera LabSen 252 Manuals

1 pdf manual(s) Apera LabSen 252 for free download (Document Types: Operation & user’s manual)

Apera LabSen 252 Operation & user’s manual Thumbnail

Apera LabSen 252 Operation & user’s manual [PDF] (2 pages)

  • Identifier: id-2030526
  • Brand: Apera
  • Device: Apera LabSen 252 Measuring Instruments
  • Type: Operation & user’s manual, PDF
  • Key Aspects: Performance Optimization Tips, Troubleshooting Information, Component Longevity Optimization
  • UPD Date: 18.04.2026
  • Source File: 2257332.pdf
  • Pages: 2
  • Description: Product usage manual for the Apera LabSen 252.
Pages Preview:
  • Apera LabSen 252 Operation & user’s manual preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
LabSen 252 Glass Spear pH Electrode User Manual LabSen electrochemical sensors are premium pH electrode with manufacturing technology and key components imported from Switzerland. LabSen252 adopts spear type glass membrane, which can easily pierce solid or semi-solid medium. This electrode is suitable for cheese, meat, fruit and vegetable testing. This probe has following features: ⚫ Impact-resist membrane, there is no danger of electrode breakage during normal use. ⚫ Blue gel inner solution, does not flow and will not cause bubble. ⚫ Maintenance-free polymer electrolyte, non-diaphragm structure. ⚫ Long life reference system, has better stability and service life. 1 Technical Data Measuring Range (0 ~ 14) pH Electrolyte Polymer Temperature Range (0 ~ 80) °C Soaking Solution 3M KCl Shaft Material Lead-free Glass Electrode Dimension Electrode (Ø12×100) mm Measuring Tip (Ø6×35) mm Membrane Shape Tapered Reference Long Life Connector S7 Junction Ceramic+Single Pore Cable S7-BNC / Ø3×1m 2 Usage and Maintenance 2.1 Connect electrode to S7-BNC cable, and then connect BNC plug to the input on the pH meter. 2.2 When measuring, please unscrew the bottle cap, pull out the electrode and rinse it with deionized water. After using, please put the electrode back into the bottle and screw tight the cap. 2.3 After long time exposure in air, Polymer electrolyte will cause shrinkage. It will not happen in measurement status. The electrode must be soaked in 3M KCl solution for storage. After long time soaking, there will be some floccules dissolving out from 3M KCl solution, this is normal phenomenon. Before pulling out or putting back the electrode, make sure to fully loosen the blue cap on the storage sleeve so that the electrode can move in and out smoothly.

Similar Manuals in the Measuring Instruments Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
FILL-RITE FR1118-A10

#SVL225: FR1118-A10 Measuring Instruments Operation & user’s manual

6 783 181 06-06-2026 view all manuals
Radio Shack TRS-80

#STYY18: TRS-80 Desktop Technical manual

42 480 116 29-03-2026 view all manuals
VOLTCRAFT CO-700

#1SW11A: CO-700 Measuring Instruments Operating instructions manual

8 780 156 06-04-2026 view all manuals
Honeywell AutoSet 1500

PDF User Manual (@RQCMS2), Honeywell AutoSet 1500 Measuring Instruments (08-04-2026)

63 1032 176 08-04-2026 view all manuals
Emerson Rosemount 5900

PDF User Manual (@L11U91), Emerson Rosemount 5900 Measuring Instruments (22-07-2026)

62 1400 238 22-07-2026 view all manuals
patura P4500

#YKX148: P4500 Power Supply Operation & user’s manual

76 444 76 30-03-2026 view all manuals