Manual [PDF] (16 pages)
- Updated: 02.05.2026
Document Preview & Text Transcription
The installer’s choice
cdvigroup.com
ENGLISH
EN
FRANCAIS
FR
DGLP60WLC
Hands-Free Proximity Card Reader - Wiegand
Lecteur Proximité Main Libre - Wiegand
all-guides
com
2
cdvigroup.com
EN
DGLP60WLC
Hands-Free Proximity Card Reader - Wiegand
INSTALLATION MANUAL
1] PRODUCT PRESENTATION
26, 30 or 44 bits Wiegand outputs.
Connection to the controller via
the Wiegand bus interface (INTBUSW).
Polycarbonate reader.
Surface mount.
Reading distance from 30 to 60cm*.
Dimensions (L x W x D): 400 x 325 x 25mm.
Open collector outputs (Clock, Data 0 and Data 1).
Reading distance: up to 30cm with tags
(ref. PPC*) and up to 60cm with cards (ref. CPE*).
Self-contained electronics.
Audible and visual feedback.
Input voltage: 12V dc.
Consumption: 450mA.
Complies with European R&TTE directive 99/5/EC
and harmonised standards: ETS 301 489
and ETS 300-330-1-Ed 2001. Complies with applicable
EMC standards: EN 50133, EN 50130-4.
2] RECOMMENDATIONS
Installation recommendations
1. To secure your installation, make sure
that the varistor is mounted in parallel
on the terminals of the lock with the power supply.
2. Make sure that when mounting 2 Hands Free
readers, to keep a minimum distance between
the units to avoid reading the badges on both
readers simultaneously.
3. When installing a reader near a loop conductor,
a conductor in the form of a close loop, a metal
plate then make sure to keep a cleared area around
the reader of 1M on both sides and 1M at the back.
4. In some cases, put 0V to earth.
Mounting on a post
Avoid all conducting metals. Do not install
the reader in a closed conductor frame.
Recommended wiring
4 pairs 6/10th or AWG24 cable.
Environment
If you install these readers in a marine/salt
environment, we recommend spraying
a varnish coating on the terminal block
after wiring to prevent oxidation.
Recommended power supplies
There are two suitable power supplies for these
Wiegand «proximity» readers: ARD12 and BS60.
Do not used switching power supply. These pro-
ducts must be powered in 12Vdc and the power
supply should be certified EN60950-1:2006/
A11:2009 standards and should be designed
to be a low power supply source.
Unfavourable situations
Avoid proximity to sources of electromagnetic
interference such as :
- IT transmission cables.
- Main power cables.
- Variators.
- Inverters.
- Computer monitors.
- Vehicle presence detection loop.
* This performance level is for an environment free from any electromagnetic disruptions.
IP53
-40°C to +70°C
CE certification
R&TTE certification
WEEE
Environmental
tests: vibrations
Thank you for buying our products and for the confidence you placed
in our company.
3
cdvigroup.com
EN
DGLP60WLC
Hands-Free Proximity Card Reader - Wiegand
INSTALLATION MANUAL
ODIAX® tools
Sticker
M5x42.5 DIAX®
screws
M5 metal plugs
DGLP60 WLC
reader
1
1
4
4
Orientation :
% distance :
30°
60%
25°
80%
0°
100%
Care : The more the badge is inclined
perpendicularly, the more the reading distance
will be reduced.
3] MOUNTING KIT
- Reinforced concrete walls.
- Any equipment not in conformity
with the EMC directive.
Optimisation
1. When the reader is installed in a position that could
present one the previously mentioned unfavourable
situations, a few simple actions can sometimes
improve the performance of the reader:
Try to analyse the environment to attempt
to identify one of the possible sources
of interference (radiation, metal, etc).
Check the connections and the wiring.
Check the voltage on the power supply
and the voltage on the terminal block on the reader.
Test the reader in a different configuration
from the one initially intended:
- Move the reader.
- Change its orientation.
2. If the reader works better in a different
configuration or position, it means
that the initial position is not optimal
and then should be changed until you find
the best configuration.
Note : Test the card reader with a 12V
battery and proceed to the installation.
3. At start-up the DGLP60WLC reader perform an
auto calibration during 10 minutes to reach
optimal operation.
Using the badge
1. Present the badge with its face towards
the reader approaching slowly until the reading
signal is obtained.
2. It is not necessary to shake the badge
in front of the reader.
3. The badge should be presented
as parallel as possible to the reader
to optimize the reading distance.
Pages Preview: