© 2000 Copeland Corporation
Printed in U.S.A. 2 Copeland 10-1313 © 2000 Copeland Corporation Printed in U.S.A. 2 Figure 2 Part Winding Start (PWS) For 3-Phase Monitors -
© 2000 Copeland Corporation
Printed in U.S.A. 4 Copeland 10-1313 Table 1 Troubleshooting Symptom LCD Readout LED Status Corrective Action Load will not energize Phase Avg (Phase Average) Load LED OFF, Fault LED blinking 1)Confirm that the control input is properly connected. 2)Press [FAULT] to obs -
© 2000 Copeland Corporation
Printed in U.S.A. 10-1313 3 Copeland 10-1313 LOAD/ALARM RELAY The relay shown in Figure 3 is used to control the contactor coil. Wire terminals 4 and 6 are in series with the control circuit as shown in Figure 3. If needed, terminal five (the normally closed side of th -
© 2000 Copeland Corporation
Printed in U.S.A. 10-1313 1 Copeland 10-1313 Application Engineering Bulletin AE-1313 Issued September, 2000 GUIDELINES TO USING A THREE PHASE VOLTAGE MONITOR 10-1313 INTRODUCTION A phase monitor can be used with any three phase motor. A monitor such as the Copeland 08