OWNER’S MANUAL (English)
TO BE OPERATED BY QUALIFIED PERSONNEL ONLY
CC220E
Refrigerant Charging Scale
www.
.com
[email protected]
1.800.561.8187
2
Imperial metric
weigt units
OVERVIEW
The Compute-A-Charge CC220E is a battery operated, precision scale with a visual charge and
recover alarm feature, for weighing, charging and recovering refrigerants used in HVAC/R systems.
• Weight Capacity - 220 lb (100 kg)
• Weight Accuracy - 0.015% of reading [or +/- selected resolution, whichever greater]
• Display Resolution (Selectable) - User can select from 4 different increments (see specifications)
• Continuous Battery Life - One 9V = 75 hours; Two 9V (included) = 150 hours
• 7 Button Keypad - Easy to navigate
• Charge / Recover Visual Alarm Feature - Alerts user when approaching programmed charge
amount or overfill limit
• Auto-Power Off (APO), - To conserve battery power, and when not in use, the scale can
be set to turn OFF after any of 5 different time increments (see specifications)
• Smart Awake Feature - Displays weight at time of Auto-Off
SCALE LAYOUT
KEY FEATURES
Durable cast aluminum
platform and base
Battery level indicator
Large 1/2” (12 mm) numbers
7 button keypad
6’ (1.8 m) Flexcord
Runs on one 9V
battery (or 2 included)
360˚ Swivel hook
with magnetic back
Durable
molded case
Power: Turn scale On / Off
Go/Hold:
Start or pause charge or recover
Up: Increase weight
Set/Reset: Input or reset modes
Down: Decrease weight
Units: Select Lb or Kg
Tare:
Zero’s out the display
www.
.com
[email protected]
1.800.561.8187
3
GENERAL SAFETY INSTRUCTIONS
Please read, follow and understand the contents of this entire manual, with special attention
given to Danger, Warning and Caution statements.
FOR USE BY PROFESSIONALLY TRAINED AND CERTIFIED OPERATORS ONLY. MOST STATES,
COUNTRIES, ETC., MAY REQUIRE USER TO BE LICENSED. PLEASE CHECK WITH YOUR
LOCAL GOVERNMENT AGENCY.
DANGER: Overfilling a recovery tank may cause a violent rupture resulting in severe injury
or even death. As a minimum, please use a scale to continuously monitor
recovery tank weight.
WARNING: All hoses may contain liquid refrigerant under pressure. Contact with refrigerant may
cause frostbite or other related injuries. Wear proper personal protective equipment
such as safety goggles and gloves. When disconnecting any hose, please use extreme
caution as high pressure refrigerant may be present.
WARNING: Avoid breathing refrigerant vapors and lubricant vapor or mist. Breathing high
concentration levels may cause heart arrhythmia, loss of consciousness, or even
cause suffocation. Exposure may irritate eyes, nose, throat and skin. Please
read manufacturer’s Material Safety Data Sheet for further safety information on
refrigerants and lubricants.
WARNING: Make certain all safety devices are functioning properly before operating equipment.
1. POWER KEY
a.Press to turn power ON or OFF.
2. UNITS KEY
- Press to select
your desired weight unit (LB to KG,
or KG to LB).
3. TARE KEY
a. While in WEIGH mode - Press to Tare
(“zero out”) the scale display.
b. While in HOLD mode - Tare function is
not active.
c. While in CHARGE/RECOVER mode -
Resets programmed amount to 0.
4. GO/HOLD KEY
a. Starts CHARGE or RECOVER modes (per
data entered after pressing the Set key).
b. While running in CHARGE or RECOVER
modes, pressing this key will place the
CC220E into HOLD (pause).
5. SET/RESET KEY
There are 5 modes to select and/or where
information can be entered: Scale (Weigh),
Charge, Recover, APO, Resolution
a. Press to scroll through different modes
b. Press while in any mode to terminate
and return to SCALE mode.
6. UP KEY
a. Increases the weight displayed (one
resolution unit) for every actuation, or if
continuously pressed.
7. DOWN KEY
a. Decreases the weight displayed (one
resolution unit) for every actuation, or if
continuously pressed. A visual reminder
will flash if the display reaches 0.
7 BUTTON KEYPAD (FUNCTIONS & DEFINITIONS)
www.
.com
[email protected]
1.800.561.8187