Crown 1160A Manuals

3 pdf manual(s) Crown 1160A for free download (Document Types: Specification sheet, Architectural & engineering specifications, Operation manual)

Available Documents for 1160A:

Crown 1160A Specification sheet Main Page Preview

Specification sheet [PDF] (2 pages)

  • Brand: Crown
  • Model: 1160A
  • Format: PDF
  • Key Aspects: Unpacking and Inspection Guidelines, Periodic Inspection Checklists, Component Overview and Descriptions
  • Updated: 02.05.2026
  • Source File: 122728.pdf
  • Pages: 2
  • Description: Full technical guide for the Crown 1160A.

Document Preview & Text Transcription

T he Crown® 180A, 280A, and 1160A are high-value amplifi ers for commercial and industrial audio. They provide 4-ohm and constant-voltage outputs (70V and 100V). The amps are part of Crown’s Commercial Audio Series, which also includes mixers and mixer- amps. These low-cost units provide all necessary features in a simple building-block format. The amplifi ers vary in their number of inputs, number of outputs, and power range: • 180A has 1 input and one 80W power amplifi er for single-zone systems. • 280A has 2 inputs and dual 80W power ampli- fi ers for two-zone systems. • 1160A has 1 input and one 160W power ampli- fi er for single-zone systems. Some applications include schools, hospitals, factories, restaurant/retail, houses of worship, fi tness facilities, A/V boardrooms, prisons, and small offi ces. Typical uses are paging, background music, security and evacuation instructions. The sound system can be upgraded as a facility expands. For example, you can add more mixers for more inputs, or add more power amps (or mixer-amps) to handle more zones. Specifi cations Performance Frequency Reponse (at 1 watt from 4-ohm tap): 70 Hz to 19 kHz +/- 1 dB. Frequency Response (at line out): 20 Hz to 20 kHz +/- 1 dB. Power Bandwidth (at 4-ohm tap, 2 dB below maxium 1 kHz power): 50 Hz to 20 kHz with < 0.5% THD Signal to Noise Ratio (ref. to rated power, master volume at minimum): 85 dB. DC Output Offset: < ±5 mV. THD: Less than 0.5% at rated power at 1 kHz. Input Sensitivity (for full output at maximum gain): 800 mV. Input Impedance (nominal): 100 kilohms. Minimum Load Impedance: 100V output: 160 ohms. 70V output: 80 ohms. 4-ohm output: 4/8 ohms. Crosstalk (all controls at “10”): –70 dB at 1kHz. Line Output Level (nominal): 1V into 10 kilohms. AC Line Voltages Available: 100V 50/60 Hz 120V 60 Hz 220V 50/60 Hz 230V 50/60 Hz 240V 50/60 Hz Operating Temperature/Humidity: 0° C to 40° C at 95% relative humidity (non-condensing). Storage Temperature: –20° C to 85° C. Front Panel Controls and Indicators Power Switch: Pushbutton on-off switch. The power switch does not affect the 24V DC auxiliary power input. Power Indicator: Blue LED indicates power on. Output Signal Presence Indicator: Green LED, one for each output channel, illuminates when output signal level exceeds 100 mV (45 dB below full power) from the 4-ohm tap. Clip Indicators: Red LED, one per output channel. Illuminates at threshold of audible distortion. Master Volume Controls: One per output channel. Detented potentiometer with knob. Tone Controls: Bass and Treble non-detented potentiometers on each channel. Bass ±10 dB at 100 Hz, Treble ±10 dB at 10 kHz. Back Panel Controls and Connectors Reset Switch: Resets the circuit breaker that protects the power supply. 220/230/240V units have a fuse instead. AC Power Inlet: Detachable IEC. Auxiliary Power Input: 2-position terminal strip for 24 VDC (±10%) backup power. Accepts up to 14 AWG terminal forks. Amplifi er Outputs Connectors: One per channel, 4-position terminal strip with COM (Common), 4 ohms, 70V and 100V terminals. Accepts up to 10 AWG terminal forks. Non-touch cover included. Output VCA Connector: One for every two chan- nels, 4-pin Phoenix-type connector for two VCA control lines of +10 VDC and ground. Compatible with Crown 1-VCAP and 4-VCAP modules. C O M M E R C I A L A U D I O S E R I E S • 1 or 2 inputs, 1 or 2 amplifi er output chan- nels. • Ideal for commercial and industrial use • Balanced Phoenix-type line inputs; touch- proofed screw-terminal speaker outputs • Advanced protection system includes output current limiting, DC protection, circuit breaker/fuse, and thermal protection; details available online at www.crownaudio.com • Three-Year, No-Fault, Fully Transferable War- ranty completely protects your investment and guarantees its specifi cations Features 1 kHz Power 80W Minimum guaranteed power into 4 ohms or 70V/100V output 180A *1 kHz Power: refers to maximum power in watts at 1 kHz with 0.5% THD. * 1 kHz Power 80W Minimum guaranteed power per channel into 4 ohms or 70V/100V output 280A *1 kHz Power: refers to maximum power in watts at 1 kHz with 0.5% THD. * 1 kHz Power 160W Minimum guaranteed power into 4 ohms or 70V/100V output 1160A *1 kHz Power: refers to maximum power in watts at 1 kHz with 0.5% THD. * 180A 280A 1160A B T B T Crown International 1718 W. Mishawaka Rd. Elkhart, IN 46517-9439 TEL: 574-294-8200 FAX: 574-294-8FAX www.crownaudio.com 9/07 138118-2A Specifi cations subject to change without prior notice. Latest information available at www.crownaudio.com. Crown and Crown Audio are registered trademarks of Crown International. Other trademarks are the property of their respective owners. Printed in U.S.A. © 2007 Crown Audio®, Inc. Line Out Connector: One 3-pin balanced Phoenix- type connector per output channel. Post master, pre-VCA. Level controlled by master volume control. Amp Input Connector: 3-pin Phoenix-type, high-impedance balanced, one per amplifer channel. Cooling Convection cooled. Protection Current Limit Protection: Included. Thermal Limit Protection: Over-temperature thermal cutout. DC-Fault Load Protection: Included. Included Accessories Power cord Detachable rack ears Screws for rack ears Non-touch cover for output connectors Phoenix-type connectors Spade lugs Optional Accessories 1-VCAP remote volume control for one channel. 4-VCAP remote volume control for four channels. Dimensions EIA Standard 19-inch (48.3-cm) rack mount width (EIA RS-310-B) with rack ears, 3.5-inch (8.9-cm) height and 12.2-inch (31.0-cm) depth behind the mounting surface (not including non-touch cover). 4.1 inches (10.5 cm) high including feet. 13.9 inches (35.2 cm) deep from front of knobs to back of non-touch cover. Weight Net Weight: 180A: 21.0 lb (9.5 kg) 280A: 25.3 lb (11.5 kg) 1160A: 25.3 lb (11.5 kg) Shipping Weight: 180A: 26.0 lb (11.8 kg) 280A: 30.3 lb (13.7 kg) 1160A: 30.3 lb (13.7 kg) 280A back panel. 180A and 1160A are similar except for the number of channels. Crown’s Three-Year, No-Fault, Fully Transferable Warranty Crown offers a Three-Year, No-Fault, Fully Transferable Warranty for every new Crown amplifi er-—an unsurpassed industry standard. With this unprecedented No-Fault protection, your new Crown amplifi er is warranted to meet or exceed original specifi cations for the fi rst three years of ownership. During this time, if your amplifi er fails, or does not perform to original specifi cations, it will be repaired or replaced at our expense. About the only things not covered by this warranty are those losses normally covered by insurance and those caused by intentional abuse. And the coverage is transferable, should you sell your amplifi er. See your authorized Crown dealer for full warranty disclosure and details. For customers outside of the USA, please contact your authorized Crown distributor for warranty information or call 574-294-8200. 180A 280A 1160A
Crown 1160A Architectural & engineering specifications Main Page Preview

Architectural & engineering specifications [PDF] (1 pages)

  • Brand: Crown
  • Model: 1160A
  • Format: PDF
  • Key Aspects: Package Contents and Accessories List, Periodic Inspection Checklists, Storage and Care Recommendations
  • Updated: 14.07.2026
  • Source File: 122729.pdf
  • Pages: 1
  • Description: Device instruction manual for the Crown 1160A.

Document Preview & Text Transcription

Crown International 1718 W. Mishawaka Rd. Elkhart, IN 46517-9439 TEL: 574-294-8200 FAX: 574-294-8FAX www.crownaudio.com 1160A Specifi cations subject to change without prior notice. Latest information available at www.crownaudio.com. Crown and Crown Audio are registered trademarks of Crown International. Printed in U.S.A. © 2007 Crown Audio®, Inc. 9/07 138174-1B Architectural & Engineering Specifi cations C O M M E R C I A L A U D I O S E R I E S 1160A The Crown® 1160A shall be an amplifi er for commercial and industrial audio. It provides 4-ohm and constant-voltage outputs (70V and 100V). The 1160A has 1 input and one 160W power amplifi er for single-zone systems. Specifi cations The 1160A shall have the following specifi cations: Minimum guaranteed power into 4 ohms or 70V/100V output: 160W maxi- mum power at 1 kHz with 0.5% THD. Frequency Reponse (at 1 watt from 4-ohm tap): 70 Hz - 19 kHz +/– 1 dB. Frequency Response (at line out): 20 Hz to 20 kHz +/–1 dB. Power Bandwidth (at 4-ohm tap, 2 dB below maxium 1 kHz power): 50 Hz to 20 kHz with < 0.5% THD. Signal to Noise Ratio (ref. to rated power, master volume at minimum): 85 dB. DC Output Offset: < ±5 mV. THD: Less than 0.5% at rated power at 1 kHz. Input Sensitivity (for full output at maximum gain): 800 mV. Input Impedance (nominal): 100 kilohms. Minimum Load Impedance: 100V output 160 ohms, 70V output 80 ohms, 4-ohm output 4/8 ohms. Crosstalk: –70dB at 1kHz. Line Output Level (nominal): 1V into 10 kilohms. AC Line Voltages Available: 100V 50/60 Hz, 120V 60 Hz, 220V 50/60 Hz, 230V 50/60 Hz, 240V 50/60 Hz. Operating Temperature/Humidity: 0 degrees C to 40 degrees C at 95% relative humidity (non-condensing). Storage Temperature: –20 degrees C to 85 degrees C. Front Panel Controls and Indicators Front panel controls and indicators shall include the following: Power Switch: Pushbutton on-off switch. Master Volume Controls: One per output channel, detented potentiometer with knob. Tone Controls: Bass and Treble non-detented potentiometers on each channel, Bass ±10 dB at 100 Hz, Treble ±10 dB at 10 kHz. Power Indicator: Blue LED indicates power on. Output Signal Presence Indicator: Green LED, one for each input channel, illuminates when input signal exceeds 100 mV (45 dB below full power) from the 4-ohm tap. Clip Indicators: Red LED, one per output channel, illuminates at threshold of audible distortion. Rear Panel Controls and Connectors Rear panel controls and connectors shall include the following: Reset Button: Resets the circuit breaker that protects the power supply; 220/230/240V units shall have a fuse instead. AC Power Inlet: Detachable IEC. Auxiliary Power Input: 2-position terminal strip for 24 VDC (±10%) backup power; accepts up to 14 AWG terminal forks. Amplifi er Output Connector: 4-position terminal strip with COM (Common), 4 ohms, 70V and 100V terminals; accepts up to 10 AWG terminal forks, non-touch cover included. Output VCA Connector: 4-pin Phoenix-type connector for two VCA control lines of +10 VDC and ground; compatible with Crown 1-VCAP and 4-VCAP modules. Line Out Connector: One 3-pin balanced Phoenix-type connector, post master, pre-VCA, level controlled by master volume control. Amp Input Connector: 3-pin Phoenix-type, high-imped- ance balanced. Miscellaneous Cooling shall be by convection. Included protection mechanisms shall be current limiting, over-temperature thermal cutout, and DC-fault load protection. Included accessories shall be a power cord, detachable rack ears, screws for rack ears, non-touch cover for output connectors, Phoenix-type con- nectors, and spade lugs. Optional accessories shall be a 1-VCAP remote volume control for one channel, and a 4-VCAP remote volume control for four channels. The dimensions of the amplifi er shall allow for 19 inch (48.3 cm) EIA standard (RS-310-B) rack mounting. The amplifi er shall be 3.5 inches (8.9 cm) high, and 12.2 inches (31 cm) deep behind the rack-mounting surface (not including the non-touch cover). The amplifi er shall weigh 25.3 lb (11.5 kg). The amplifi er shall be designated the Crown 1160A.
Crown 1160A Operation manual Main Page Preview

Operation manual [PDF] (24 pages)

  • Brand: Crown
  • Model: 1160A
  • Format: PDF
  • Key Aspects: Component Overview and Descriptions, Critical Operational Precautions, Pre-Deployment Preparation Steps
  • Updated: 06.04.2026
  • Source File: 122727.pdf
  • Pages: 24
  • Description: Professional operation guide for the Crown 1160A.

Document Preview & Text Transcription

Operation Manual 180A Obtaining Other Language Versions: To obtain information in another language about the use of this product, please contact your local Crown Distributor. If you need assistance locating your local distributor, please contact Crown at 574-294-8000. This manual does not include all of the details of design, production, or variations of the equipment. Nor does it cover every possible situation which may arise during installation, operation or maintenance. The information provided in this manual was deemed accurate as of the publication date. However, updates to this information may have occurred. To obtain the latest version of this manual, please visit the Crown website at www.crownaudio.com. Trademark Notice: Crown, Crown Audio and Amcron are registered trademarks of Crown International. Other trademarks are the property of their respective owners. Some models may be exported under the name Amcron.® ©2007 by Crown Audio® Inc., 1718 W. Mishawaka Rd., Elkhart, Indiana 46517-9439 U.S.A. Telephone: 574-294-8200 138099-4C 9/07 Commercial Audio Series 280A 1160A B T B T B T B T 660A Commercial Audio Series Amplifiers page 2 Operation Manual Important Safety Instructions IMPORTANT Commercial Audio Series amplifiers require Class 2 output wiring. 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this apparatus near water. 6) Clean only with a dry cloth. 7) Do not block any ventilation openings. Install in accordance with the manufacturer’s instruc- tions. 8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9) Do not defeat the safety purpose of the polar- ized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10) Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. 11) Only use attachments/accessories specified by the manufacturer. 12) Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus com- bination to avoid injury from tip-over. 13) Unplug this apparatus during lightning storms or when unused for long periods of time. 14) Refer all servicing to qualified service person- nel. Servicing is required when the apparatus has been damaged in any way, such as power- supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 15) WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE. 16) DO NOT EXPOSE TO DRIPPING OR SPLASH- ING. DO NOT PLACE OBJECTS FILLED WITH LIQUID, SUCH AS VASES,ON THIS APPARA- TUS. TO COMPLETELY DISCONNECT THIS EQUIPMENT FROM THE AC MAINS, DISCONNECT THE POWER SUPPLY CORD PLUG FROM THE AC RECEPTA- CLE. THE MAINS PLUG OF THE POWER SUPPLY CORD SHALL REMAIN READILY OPERABLE. TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR BOTTOM COVERS. NO USER SERVICE- ABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. À PRÉVENIR LE CHOC ÉLECTRIQUE N’ENLEVEZ PAS LES COUVERCLES. IL N’Y A PAS DES PAR- TIES SERVICEABLE À L’INTÉRIEUR. TOUS REPA- RATIONS DOIT ETRE FAIRE PAR PERSONNEL QUALIFIÉ SEULMENT. WATCH FOR THESE SYMBOLS: The lightning bolt triangle is used to alert the user to the risk of electric shock. The exclamation point triangle is used to alert the user to important operating or maintenance instruc- tions. FCC COMPLIANCE NOTICE This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or televi- sion reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. MAGNETIC FIELD CAUTION! Do not locate sensitive high-gain equip- ment such as preamplifiers or tape decks directly above or below the unit. Because this amplifier has a high power density, it has a strong magnetic field which can induce hum into unshielded devices that are located nearby. The field is strongest just above and below the unit. If an equipment rack is used, we recommend locat- ing the amplifier(s) in the bottom of the rack and the preamplifier or other sensitive equipment at the top. Commercial Audio Series Amplifiers page 3 Operation Manual DECLARATION of CONFORMITY Crown International, Inc. Sue Whitfield 574-294-8289 [email protected] European Representative’s Name and Address: Nick Owen 35, Bassets Field Thornhill Cardiff. South Glamorgen CF14 9UG United Kingdom Equipment Type: Commercial Audio Series Family Name: Amplifiers Model Names: 180A, 280A, 1160A, 660A EMC Standards: EN 55103-1:1997 Electromagnetic Compatibility - Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professional Use, Part 1: Emissions EN 55103-1:1997 Magnetic Field Emissions-Annex A @ 10 cm and 1 M EN 61000-3-2:2001 Limits for Harmonic Current Emissions (equipment input current 16A per phase) EN 61000-3-3:2002 Limitation of Voltage Fluctuations and Flicker in Low-Voltage Supply Systems Rated Current 16A EN 55022:2003 Limits and Methods of Measurement of Radio Disturbance Characteristics of ITE: Radiated, Class B Limits; Conducted, Class B EN 55103-2:1997 Electromagnetic Compatibility - Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professional Use, Part 2: Immunity EN 61000-4-2:2001 Electrostatic Discharge Immunity (Environment E2-Criteria B, 4k V Contact, 8k V Air Discharge) EN 61000-4-3:2001 Radiated, Radio-Frequency, Electromagnetic Immunity (Environment E2, Criteria A) EN 61000-4-4:2001 Electrical Fast Transient/Burst Immunity (Criteria B) EN 61000-4-5:2001 Surge Immunity (Criteria B) EN 61000-4-6:2003 Immunity to Conducted Disturbances Induced by Radio-Frequency Fields (Criteria A) EN 61000-4-11:2001 Voltage Dips, Short Interruptions and Voltage Variation Safety Standard: IEC 60065: 2002 7th Ed. Safety Requirements - Audio Video and Similar Electronic Apparatus CAN/CSA-E60065-03 7th Ed. Audio, Video and Similar Electronic Apparatus-Safety Requirements UL 60065 7th Ed. Audio /Video and Musical Instrument Apparatus for Household, Commercial and Similar General Use. I certify that the product identified above conforms to the requirements of the EMC Council Directive 89/336/EEC as amended by 92/31/EEC, and the Low Voltage Directive 73/23/EES as amended by 93/68/EEC. Signed Title: Senior Vice President of Manufacturing Date of Issue: Jan. 1, 2006 Issued By: Crown International, Inc. 1718 W. Mishawaka Road Elkhart, Indiana 46517 U.S.A. Due to line current harmonics, we recommend that you contact your supply authority before connection. Larry Coburn FOR COMPLIANCE QUESTIONS ONLY: Commercial Audio Series Amplifiers page 4 Operation Manual Important Safety Instructions .......................................................2 Declaration of Conformity ............................................................3 1 Welcome ................................................................................5 1.1 Features ...........................................................................5 1.2 Front Panel Controls and Indicators ................................6 1.3 Back Panel Controls and Connectors................................7 1.4 66A Back Panel Controls and Connectors ........................8 2 Setup ......................................................................................9 2.1 Installation........................................................................9 2.2 How to Attach Rack Ears...................................................9 2.3 Choose Input Wire and Connectors .................................10 2.4 Choose Output Wire and Connectors ...............................10 2.5 Wire Your System ............................................................11 2.6 Remote Volume Control....................................................13 2.7 Powering Up.....................................................................13 2.8 Included Accessories........................................................13 2.9 Optional Accessories........................................................13 3 Troubleshooting .................................................................. 14 4 Specifications ..................................................................... 15 5 Service ... .............................................................................. 16 5.1 International and Canada Service ................................... 16 5.2 US Service ..................................................................... 16 5.2.1 Service at a US Service Center .............................. 16 5.2.2 Factory Service ...................................................... 16 5.2.3 Factory Service Shipping Instructions ................... 16 5.2.4 Packing Instructions................................................ 16 5.2.5 Estimate Approval................................................... 16 5.2.6 Payment of Non-Warranty Repairs.......................... 16 6 Warranty .............................................................................. 17 Product Registration.................................................................... 19 Crown Factory Service Information Form.....................................21 Table of Contents