Directed 3105 Manuals
1 pdf manual(s) Directed 3105 for free download (Document Types: Quick reference install manual)
Directed 3105 Quick reference install manual [PDF] (2 pages)
- Identifier: id-849481
- Brand: Directed
- Device: Directed 3105 Security System
- Type: Quick reference install manual, PDF
- Key Aspects: Initial Startup Checklist, Hardware Setup Instructions, Information on Regular Maintenance
- UPD Date: 28.08.2026
- Source File: 895095.pdf
- Pages: 2
- Description: Comprehensive user handbook for the Directed 3105.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
© 2012 Directed. All rights Reserved. 1 Quick Reference Install Guide Vehicle Security System Models 3105 and 3305 Guide Translations For a Spanish or French version of the Installation Guide, please download it from www.directechs.com under “Resources”. Traducción de los manuales: Para obtener una versión en Español o Francés del Manual de Instalación, descárguela de www.directechs.com bajo el título “Recursos” (“Resources”). Traduction du guide: Pour une version française ou espagnole du guide d’installation, veuillez le télécharger à www.directechs.com sous «Resources». Sensor adjustment detail Optional Sensor Port White 4 Pin Plug LED Port White 2 Pin Plug Vatet Switch Port Blue 2 Pin Plug Antenna Port (-) (+) Red/White (-) 200mA Chan 2 Output Green (-) Lock, (+) Unlock Output Blue (-) Unlock, (+) Lock Output Light Flash Jumper Red (+) 12V Constant Power Brown (+) Siren Output Yellow (+) Ignition Input Black (-) Chassis Ground Violet (+) Door Trigger Input Blue (-) Instant Trigger Input Green (-) Door Trigger Input Black/White (-) Domelight Sprvsn Output White/Blue (-) 200mA Chan 3 Output White (+/-) Light Flash Output Orange (-) 500mA GWA Output Wiring Connections Channel 2 Output: Connect to the vehicle negative (-) trunk release re- lay or other low current device 12V Constant Power: Remove the inline fuse before connecting to a wire that has (+) 12V at all times Siren Output: Connect to the (+) wire on the siren Ignition Input: Connect to a wire that has (+) 12V while the key is in the run and crank positions Chassis Ground: Connect to a scraped (bare) metal surface in the driver kick Door Trigger Input: Connect to a wrie that goes to (+) 12V when any door is opened Instant Trigger Input: Connect to a wire that goes to ground (-) when the hood or trunk are opened Door Trigger Input: Connect to a wire that goes to (-) ground when any door is opened Domelight Supervision Output: Connect to a (-) wire that will turn on the domelight Channel 3 Output: Connect to an auxiliary relay or low current device Light Flash Output: Connect to the vehicle parking light wire. This wire is programmable + or - Ground When Armed Output: Connect to a starter interrupt relay or other accessory that requires a GWA Important: NEVER connect 200mA low current outputs directly to a motor or high current device WITHOUT a relay, Programming Port: The 998T Bit- writer can be connected to this port for programming feature options. SmartStart can be connected to this port to operate the system by Smart- phone. Adjusting the shock sensor pot: 1. Securely mount the CPU (in a safe location) before adjusting 2. Turn the sensor adjustment clockwise to increase sensitiv- ity, turn counterclockwise to decrease sensitivity (-) Lock, (+) Unlock Output: Con- nect to a wire that pulses ground to activate the vehicle lock relay or to a wire that pulses (+) 12V to acti- vate the vehicle unlock relay (-) Unlock, (+) Lock Output: Con- nect to a wire that pulses (-) ground to activate the vehicle unlock relay or to a wire that pulses (+) 12V to activate the vehicle lock relay Bitwriters with a date code of 6a or older require an IC upgrade (p/n 998M). Some bitwriters with a date code of 6B do not require the IC upgrade, refer to tech tip # 1112 for more information. The Bitwriter® (p/n 998U) requires chip version 2.4 or newer to program this unit. Remote control configuration 4- button remote control configuration Feature Description A U X Arm: Lock the doors and arm the vehicle A U X Disarm: Unlock the doors and disarm the vehicle AUX Channel 2/Silent Mode: Activate Silent Mode and Auxiliary functions AUX Panic A U X and A U X Channel 3: Press together to control an Auxiliary out- put More information and full Installa- tion Guide can be found online at: www.directechs.com
Similar Manuals in the Security System Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
Apex Digital Defender II |
Defender II (Security System ePDF Manual, #I66U4G) |
16 | 127 | 21 | 17-07-2026 | view all manuals | |
Cannon Security Products Digital Door Viewer |
PDF User Guide (@F487T6), Cannon Security Products Digital Door Viewer Security System (16-04-2026) |
2 | 610 | 98 | 16-04-2026 | view all manuals | |
Cobra 63890 |
PDF User Manual (@3VG2H1), Cobra 63890 Security Camera (28-08-2026) |
2 | 831 | 183 | 28-08-2026 | view all manuals | |
Swann NVR |
Manual: Swann NVR (T37292, Upd.05-05-2026) |
9 | 1128 | 271 | 05-05-2026 | view all manuals | |
Netatmo NIS01 |
#A9PWF4: NIS01 Security System Operation & user’s manual |
17 | 839 | 152 | 13-03-2026 | view all manuals | |
AMC VOXOUT |
Security System #YQ3TJ6 |
20 | 200 | 44 | 02-04-2026 | view all manuals |