Date: February 8, 2017 To: Global Distributors and Dealers PGx975 PowerG Wireless Vanishing Door/Window Contact Overview It has come to our attention that due to improper re-assembly of the plastic portion of the PGx975 PowerG Wireless Vanishing Door/Window Contact, there is a possibility that the tamper switch of the device could become damaged, to the point where it may not properly detect a tamper condition when the case is opened, or constantly show a tamper condition even when the device is assembled. Re-Assembly Instructions To ensure that the PGx975 plastic is properly re-assembled at the time of installation or when the battery is replaced, please follow the instructions below. The re-assembely instructions will also be updated in the Installation Manual. To close the cover, complete the following steps (also seen in the image below) 1. Insert the two teeth on the front cover into the corresponding slots on the base. 2. When the cover is at a 30-degree angle to the base, push it into place until you hear a click.
DSC PG4975 Installation instructions [PDF] (4 pages)
- Identifier: id-847152
- Brand: DSC
- Device: PG4975 Security Sensors
- Type: PDF
- Key Aspects: Operational Mode Explanations, Technical Support and Resource Links, Storage and Care Recommendations
- UPD Date: 19.03.2026
- Source File: 897424.pdf
- Pages: 4
- Description: Technical operations guide for the DSC PG4975.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
PG9975/PG8975/PG4975 PowerG Series Wireless Door and Window Contact Installation Instructions Operation The PG9975/PG8975/PG4975 Door and Window Contacts are fully supervised, PowerG magnetic contact devices. They include a built-in reed switch (that opens upon removal of a magnet placed near it). The device transmits alarm notifications to the control panel and is supervised using the PowerG 2-way communications protocol. The LED lights green/yellow/red, according to signal strength, upon first insertion of the battery and for the test period of 15 min. LED does not light while a supervision or alarm message is being transmitted. Operating power is obtained from an on-board 3 V Lithium battery. Built- in link quality indicators reduce installation time by eliminating the need for the installer to physically approach the control panel. Note: For UL/ULC installations use this device only in con- junction with compatible DSC wireless receivers: HSM2HOST9, HS2LCDRF(P)9, HS2ICNRF(P)9 and PG9920. Low-Battery Detection The PGx975 includes low-battery condition detection. When this condition is detected a trouble message is transmitted to the compatible receiver/control panel. This will provide visual identification of the unit that requires a battery change. Device Setup CAUTION! This product uses Lithium Batteries. Improper handling of lith- ium batteries may result in HEAT GENERATION, EXPLO- SION or FIRE, which may lead to personal injuries. WARNING! DANGER OF EXPLOSION IF BATTERIES ARE INSTALLED INCORRECTLY. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER. DISPOSE OF USED BATTERIES ACCORDING TO THE MANUFACTURER'S INSTRUC- TIONS KEEP AWAY FROM SMALL CHILDREN: IF SWAL- LOWED PROMPTLY SEE A DOCTOR. Do not try to recharge these batteries. Note: Installation and battery replacement should be done by service persons in indoor non-hazardous locations only. Note: To ensure the continued operation of all wireless devices after performing a system default, a global upload of all wire- less programming via DLS is recommended before defaulting the system. After completing the system default, download the wireless programming. Legend A. Enroll button B. Battery Polarity C. Reed switch on underside of PC Board (in unit) D. Symbol on side of the case indicates location of reed switch E. Magnet F. 1/4" space maximum (6mm) G. Back Tamper break-away base segment (PG8975 only) H. Mounting holes Installing the battery 1. Insert a 4 mm flat screwdriver into the slot of the plastic cover, and flex the slot to open that side of the plastic cover. 2. Insert the screwdriver into the slot on the other side of the plastic cover and repeat the procedure, and then remove the cover. 3. Insert the battery at an angle while observing battery polarity and then press down on the battery. Note: When manually program- ming wireless devices, if a device has been powered up for more than 48 hours it cannot be enrolled into the system until the device has been tampered and restored. When programming the panel using the Quick Enroll procedure follow the steps detailed in Enroll the Device into the System. Note: After restoring a low battery trouble the system may take up to 5 minutes to clear the trouble. Enroll the Device into the System To quick enroll: 1. On a keypad press [*] [8] [Installer Code] [804] [000]. 2. Press and hold the device enroll button until the LED lights steady and then release the enroll button while the LED is still lit. A confirmation message then appears on the key- pad. 3. Press [*] key to confirm ID. 4. Enter [3 digit zone #]. 5. Enter [3 digit zone type]. 6. Enter [1 digit partition #] for all desired partitions and press [#]. If using an LCD keypad you can scroll to the desired partitions and press [*] to toggle the partition. 7. On an LCD keypad enter the label by using word library. To pre-enroll: 1. Remotely configure the unique ID number into the system. For more information see the HSM2HOST manual. 2. When on-site, press the device enroll button. Note: If the wireless device has been powered for more then 48 hours without being enrolled, tamper and restore the device to enroll it. Mounting the Device It is highly recommended to attach the transmitter to the top of the door/window on the fixed frame and the magnet to the door or window. Ensure that the magnet is located not more than 6 mm (0.25 in.) from the transmitter’s marked side. Placement Testing Before permanently mounting any wireless device, temporarily mount the device and perform a placement test. 1. Tamper the device by removing the cover. 2. Replace the cover to restore the tamper. 3. Trip the device by opening the door or window and verify the red LED blinks, indicating detection. 4. After 2 seconds the LED blinks 3 times.The following table indicates received signal strength. IMPORTANT! Only GOOD or STRONG signal strengths are acceptable. If you receive a POOR signal from the device, re- locate it and re-test until a GOOD or STRONG signal is received. Note: For UL/ULC installations, only STRONG signal levels are acceptable. After installation verify the product functional- ity in conjunction with the compatible receivers HSM2HOST9, HS2LCDRF(P)9, HS2ICNRF(P)9 and PG9920. Note: For detailed placement instructions refer to the control panel Reference Guide. Gap Separation Note: For EN50131-2-6 compliant installations use contact and magnet only for axis X movement when installed on metallic (ferrous) materials. Mounting Procedure Note: Adhesive tape not to be used for EU Market. For PG4975 and PG9975: 1. Peel away the release liners from the two strips of double- sided adhesive tape and attach to the device and magnet. 2. Align the device with the magnet according to the location marks and fasten the device and magnet to the mounting surface. For PG8975: 1. Mark and drill 2 holes in the mounting surface (3 holes for back tamper). Fasten the base with the screws. 2. Insert the screws. Make sure that the screw heads are pressed against the sur- face of the plastic cover and per- pendicular to the plastic cover. 3. Align the device with the magnet according to the location marks and fasten the device and magnet to the mounting surface. Configuration To enter the wireless configuration section enter [804][Zone Number]. Device Toggles Specifications Frequency Band (MHz) - CE Listed PG4975: 433MHz; CE/ EN listed PG8975: 868MHz; FCC/IC/UL/ULC listed PG9975: 912-919MHz Modulation: GFSK Communication Protocol: PowerG Supervision: Signaling at 256 sec. intervals Battery: 3 V Lithium CR2032 type battery, Varta. 230mAh Battery Life Expectancy: 5 years (not tested by UL/ULC) Quiescent Current: 4μA Low Battery Threshold: 2.1 V Operating Temperature: -10ºC to +55ºC (UL only verified the range 0º-49ºC) Humidity: up to max. 93%RH (UL only verified up to max 85%RH) Dimensions: (LxWxD)62 x 25.4 x 6.1 mm (2-1/2 x 1 x 1/4 in.) Weight (including battery): 12g (0.42 oz) Color: White or brown Compatible Receivers 433MHz Band: HSM2HOST4; HS2LCDRF(P)4; HS2IC- NRF(P)4; PG4920 868MHz Band: HSM2HOST8; HS2LCDRF(P)8; HS2IC- NRF(P)8; PG8920 912-919MHz Band: HSM2HOST9; HS2LCDRF(P)9; HS2IC- NRF(P)9; PG9920 Note: Only devices operating in band 912-919MHz are UL/ ULC listed. Note: Only model PG9975 operating in the frequency band 912-919MHz is UL/ULC listed. UL/ULC Notes The PG9975 has been listed by UL/ULC for residential bur- glary applications in accordance with the requirements in the Standards UL 634 and ULC/ORDC634 for Door and Window Contact. For UL/ULC installations use this device only in conjunction with compatible DSC wireless receivers: HSM2HOST9, HS2LCDRF(P)9, HS2ICNRF(P)9, and PG9920. Europe: The PG4975 and PG8975 are compliant with the RTTE requirements - Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999. The PG8975 is certified by Applica Test and Certification to the following standards: EN50131-2-6, EN50131-1 GRADE 2, CLASS II, EN50131-6 Type C. Applica Test and Certification has certified only the 868 MHz variant of this product. According to EN 50131-1:2006 and A1:2009, this equipment can be applied in installed systems up to and including Security Grade 2, Environmental Class II. UK: The PG8975 is suitable for use in systems installed to conform to PD6662:2010 at Grade 2 and environmental class 2 BS8243. The Power G peripheral devices have two- way communication functionality, providing additional benefits as described in the technical brochure. This functionality has not been tested to comply with the respective technical requirements and should therefore be considered outside the scope of the product’s certi- fication. FCC COMPLIANCE STATEMENT WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protec- tion against harmful interference in residential installations. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and tele- vision reception. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such inter- ference, which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures: – Re-orient or re-locate the receiving antenna. – Increase the distance between the device and the receiver. – Connect the device to an outlet on a circuit different from the one that supplies power to the receiver. – Consult the dealer or an experienced radio/TV technician. This equipment complies with FCC and IC RF radiation expo- sure limits set forth for an uncontrolled environment. This device complies with FCC Rules Part 15 and with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any inter- ference that may be received or that may cause undesired oper- ation. Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploita- tion est autorisee aux deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appar- eil doit accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionne- ment. PG9975/PG8975/PG4975 Instructions d'installation du con- tact de porte et fenêtre sans fil PowerG Series Fonctionnement Les contacts de porte et fenêtre PG9975/PG8975/PG4975 sont des dispositifs à contacts magnétiques PowerG, entièrement supervisés. Ils possèdent un commutateur à lames (qui s'ouvre à la suite du retrait de l'aimant placé à proximité). Le dispositif transmet les notifications d'alarme à la centrale et est supervisé en utilisant le protocole de communication bidirectionnelle PowerG. Le voyant lumineux s'allume en vert/jaune/rouge, selon la force du signal, après avoir inséré la batterie et pendant une durée de test de 15 min. Le voyant ne s'allume pas alors qu'un message d'alarme ou de supervision est transmis. L'ali- mentation de fonctionnement est fournie par une batterie intégrée au lithium de 3 V. Les indicateurs de qualité de liaison intégrés réduisent les temps d'installation en supprimant la nécessité de l'installateur d'être physiquement à proximité de la centrale. Remarque : Pour les installations UL/ULC, utilisez unique- ment ces dispositifs en association avec des récepteurs sans fil DSC compatibles : HSM2HOST9, HS2LCDRF(P)9, HS2IC- NRF(P)9 et PG9920. Détection de niveau faible de batterie Le PGx975 possède une fonction de détection de niveau faible de batterie. Quand cet état est détecté, un message de problème est transmis à la centrale ou au récepteur compatible. Une sig- nalisation visuelle est ainsi assurée pour l'unité qui a besoin d'un remplacement de batterie. Réglage du dispositif ATTENTION ! Ce produit utilise des batteries au lithium. La manipulation incorrecte des piles au lithium peut engendrer UNE PRODUC- TION DE CHALEUR, UNE EXPLOSION ou UN INCENDIE, qui peuvent provoquer des blessures personnelles. AVERTISSEMENT ! DANGER D'EXPLOSION SI LES PILES SONT INSTALLÉES DE FAÇON INCORRECTE. REMPLACEZ UNIQUEMENT LES PILES PAR DES PILES IDENTIQUES OU ÉQUIVALENTES, RECOMMANDÉES PAR LE FABRI- CANT. ÉLIMINEZ LES PILES USAGÉES SELON LES INSTRUCTIONS DE SON FABRICANT. GARDEZ-LES HORS DE PORTÉE DES ENFANTS EN BAS ÂGE. SI LES PILES SONT AVALÉES, CONSULTEZ IMMÉDIATEMENT UN MÉDECIN. N'essayez pas de recharger ces piles. Remarque : Le remplacement et l'installation de la batterie doivent être réalisés exclusivement par un agent de service dans des emplacements intérieurs non dangereux. Remarque : Pour garantir le fonctionnement continu de tous les dispositifs sans fil après avoir réalisé une réinitialisation aux valeurs par défaut, un téléchargement général de toute la pro- grammation sans fil par DLS est recommandé avant de réini- tialiser le système. Après avoir complété la réinitialisation aux valeurs par défaut du système, téléchargez la programmation sans fil. Légende A. Bouton d'attribution B. Polarité de la batterie C. Commutateur à lames sur le dessous du circuit imprimé (dans l'unité) D. Un symbole sur le côté du boîtier indique l'emplacement du commutateur à lames E. Aimant F. espace minimum de 6 mm (1/4") G. Segment de la base amovible à contact anti-sabotage arrière (PG8975 uniquement) H. Trous de fixation Installer la pile 1. Insérez un tournevis plat de 4 mm dans la fente du couvercle en plastique et courbez légèrement la fente pour ouvrir le côté du couvercle en plastique. 2. Insérez le tournevis dans la fente de l'autre côté du couvercle en plastique et répétez cette opération puis retirez le couvercle. LED response Signal Strength Green LED blinks STRONG Orange LED blinks GOOD Red LED blinks POOR No blinks No communication + A B } C E D F Metallic (Ferrous) Materials Nonmetallic/Metallic (nonferrous) Materials Direction of Movement of the Mag- net Approach/ Make Remove/ Break Approach/ Make Remove/ Break Axis X >9mm <12mm >12mm >14mm Axis Y >9mm <11mm >20mm >22mm Axis Z >9mm <12mm >27mm >30mm Recommended maximum gap separation for installation (on specified materials and axes of use) is 6mm (0.24”). [001][04] Supervision - Default [Y] Enables supervision of the device. Z X Y G H + A B D-304589