Eelectron AD84A02KNX Manuals
2 pdf manual(s) Eelectron AD84A02KNX for free download (Document Types: Manual , Quick start manual)
Eelectron AD84A02KNX Manual [PDF] (2 pages)
- Identifier: id-1896402
- Brand: Eelectron
- Device: Eelectron AD84A02KNX Control Unit
- Type: Manual , PDF
- Key Aspects: System Connectivity and Wiring Basics, Additional Modules and Accessories Guide, Model Variations and Compatibility
- UPD Date: 05.07.2026
- Source File: 1826360.pdf
- Pages: 2
- Description: Official user handbook for the Eelectron AD84A02KNX.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Il modulo Interfaccia Analogico / Digitale AD84A02KNX è carat- terizzato da 4 ingressi digitali per contatti puliti, 4 ingressi confi- gurabili come digitali per contatti puliti o analogici per lettua di sonde di temperatura e 4 uscite per led. Gli ingressi digitali possono interfacciare sensori, pulsanti tradi- zionali, ecc; i 4 canali di uscita a bassa tensione possono pilotare LED per la visualizzazione di stati su pulsantiere o in pannelli sinottici. Gli ingressi 5 ÷ 8 configurati come analogici permettono di abili- tare fino a 2 sonde di temperatura (con soglia On/Off) e 2 termo- stati per il controllo di apparecchiature di riscaldamento / condi- zionamento, valvole, ventilconvettori a 2 / 4 tubi, etc.. Il dispositivo è dotato di opportuna interfaccia di comunicazione con il bus tipo TP1 (coppia intrecciata) a standard europeo KNX conforme alle normative di settore CEI EN 50090. AD84A02KNX module includes 4 digital inputs to interface free potential contacts; 4 analog / digital inputs for free potential con- tacts or temperature sensors and 4 led outputs. Digital inputs can interface sensors, traditional buttons, etc; 4 led output channels at low voltage can drive LED for synoptics panels or switches. Inputs 5 ÷ 8, set as analog inputs, can enable up to 2 temperature probes (with On/Off threshold) and 2 thermostats to control hea- ting and cooling equipments, valves, 2 and 4 pipes fan coils; etc.. The device is equipped with appropriate communication interface with the bus type TP1 (twisted pair) KNX European standard, ac- cording CEI EN 50090. Scaricabile dal sito: www.eelectron.com Numero massimo indirizzi di gruppo: 50 Corrisponde al numero massimo di indirizzi di gruppo diversi che il dispositivo è in grado di memorizzare. Numero massimo associazioni: 63 Corrisponde al numero massimo di associazioni tra oggetti di comunicazione e indirizzi di gruppo che il dispositivo può me- morizzare. Attenzione: esiste un limite al numero di associazioni che si possono creare, sullo stesso dispositivo, tra oggetti di comuni- cazione in trasmissione (per esempio gli ingressi) e in ricezione (per esempio le uscite). Qualora si voglia associare un indirizzo di gruppo usato su un oggetto di comunicazione in trasmissione (un ingresso), ad un oggetto di comunicazione in ricezione (una uscita) che ha già un indirizzo di gruppo precedentemente associato si ricorda che è possibile aggiungere un massimo di 13 indirizzi di gruppo di questo tipo sull’intero dispositivo. Downloadable from website: www.eelectron.com Maximum number of group addresses: 50 This is the maximum number of different group addresses the de- vice is able to memorize. Maximum number of associations: 63 This is the maximum number of associations between commu- nication objects and group addresses the device is able to me- morize. Caution: there is a limit to the number of associations that can be created, on the same device, between transmission communica- tions objects (i.e. output feedback) and receiving communication objects (i.e. outputs). If you want, on the same device, add a group address linked to a transmission communication object (feedback) to a receiving communication object (output) which already has a different group address associated, please note that you can add a maximum of 13 group addresses of this kind for the whole device. Alimentazione Attraverso il cavo EIB/KNX • Tensione 21..30V DC • Corrente assorbita ≤ 10 mA Ingressi�Digitali�1�-�2�-�3�-�4 • Per contatti liberi da potenziale (contatti puliti) • Max lunghezza cavi: ≤ 30 m (cavo intrecciato) • Tensione di scansione: 3,3 V DC (generata internamente) • Cablaggio con cavi AWG24 lunghezza 180 mm. Ingressi�Digitali�5�-�6�-�7�-�8 • Per contatti liberi da potenziale (contatti puliti) • Max lunghezza cavi: ≤ 10 m (cavo intrecciato) • Tensione di scansione: 3,3 V DC (generata internamente) • Connessione tramite morsetto a vite 6 poli. Ingresso�Analogico�5�-�6�-�7�-�8 • Collegabili a sonde NTC eelectron codice: • TS01A01ACC (Intervallo misura -20°C / +100°C) • TS01B01ACC (Intervallo misura -50°C / +60°C) • Max lunghezza cavi: ≤ 20 m (cavo intrecciato) • Connessione tramite morsetto a vite 6 poli. Uscite Digitali per Led 9 - 10 - 11 - 12 • 4 outputs digitali per pilotaggio led – Max 0,3 mA • Per led eelectron cod. LD00A01ACC o LD00A11ACC • Cablaggio con cavi AWG24 lunghezza 180 mm Elementi di comando • Pulsante e led EIB/KNX Dati meccanici • Custodia: in materiale plastico/nylon • Classe di protezione: II secondo la EN 61140 • Dimensioni: (alt. x larg. x prof.): 43 x 36 x 24 mm • Peso: ca. 35 g. Sicurezza elettrica • Grado di inquinamento (secondo IEC 60664-1): 2 • Grado di protezione (secondo EN 60529): IP 20 • Classe di protezione (secondo IEC 1140): III • Classe di sovratensione (secondo IEC 664-1): III • Bus: tensione di sicurezza SELV DC 21..31 V DC Power Supply Via bus EIB/KNX cable • Voltage 21..32V DC • Current consumption EIB/KNX ≤ 10 mA Digital�Input�1�-�2�-�3�-�4 • For free potential contacts (dry contacts) • Max. length of Connecting Cable: ≤ 30 m (twisted cable) • Voltage Scanning: 3,3 V DC (internally Generated) • AWG24 cables with 180 mm length Digital�Input�5�-�6�-�7�-�8 • For free potential contacts (dry contacts) • Max. length of Connecting Cable: ≤ 10 m (twisted cable) • Voltage Scanning: 3,3 V DC (internally Generated) • 6 poles terminal with screws. Analog��Input�5�–�6�–�7�-�8 • For NTC temperature probe eelectron code: • TS01A01ACC (range from -20°C to +100°C) • TS01B01ACC (range from -50°C to +60°C) • Max. length of Connecting Cable: ≤ 20 m (twisted cable) • 6 poles terminal with screws. Digital Led Output 9 – 10 – 11 -12 • 4 outputs for drive led – Max 0,3 mA • For LED eelectron code LD00A01ACC or LD00A11ACC • AWG24 cables with 180 mm length Control Elements • EIB/KNX Red LED and button Mechanical Data • Case: plastic/nylon • Protection class: II in accordance with EN 61140 • Dimensions: (width x height. X depth.): 43 x 36 x 24 mm • Weight: approx. 35 g Electrical Safety • Degree of pollution (IEC 60664-1): 2 • Degree of protection (EN 60529): IP 20 • Protection class (according to IEC 1140): III • Overvoltage class (according to IEC 664-1): III • Bus: tensione di sicurezza SELV DC 21..31 V DC Modulo�8�Ingressi�/�4�Uscite�LED AD84A02KNX Inwall�8�Input�/�4�Led�Output�Module AD84A02KNX Descrizione del prodotto e suo funzionamento Product and Applications description Programma applicativo ETS Dati tecnici ETS Application Program Technical data EN IT Rev. 2.0 TS01A01ACC Attenzione: Mantenere 6 mm di distanza da cavi in tensione! Warning: keep at least 6 mm from all live parts Sonde di temperatura Temperature probes Tolleranza della resistenza NTC NTC resistance tolerance ± 3% Intervallo di misura Measure range -20°C ÷ +100°C Cavo Cable 2 fili singolo isolamento 2 wire single insulation Colore dei cavi Cable colour Nero Black Colore NTC NTC colour Nero Black 500 ± 20 6 ± 1.5 15 max. Twin wire AWS26 PVC insulation Epoxy resin Ø D2 Twin wire AWS26 double PVC insulation Epoxy resin closed in ABS plastic cap TS01B01ACC Attenzione: Mantenere 3 mm di distanza da cavi in tensione! Warning: keep at least 3 mm from all live parts D1 = 9mm D2 = 4 mm L1 = 1250mm L2 = 49 mm Tolleranza della resistenza NTC NTC resistance tolerance ± 2% Intervallo di misura Measure range -50°C ÷ +60°C Cavo Cable 2 fili doppio isolamento 2 wire double insulation Colore dei cavi Cable colour Bianco White Colore NTC NTC colour Bianco White
Eelectron AD84A02KNX Quick start manual [PDF] (2 pages)
- Identifier: id-2012271
- Brand: Eelectron
- Device: Eelectron AD84A02KNX I/O Systems
- Type: Quick start manual, PDF
- Key Aspects: Operational Mode Explanations, Critical Operational Precautions, Product Performance Metrics
- UPD Date: 10.07.2026
- Source File: 2275587.pdf
- Pages: 2
- Description: Instructions for safe usage of the Eelectron AD84A02KNX.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
AD84A02KNXFI01010001.doc Inwall 8 Input/4 Led Output Module AD84A02KNX Product and Application Description AD84A02KNX module includes 4 digital inputs to interface free potential contacts; 4 analog / digital inputs for free potential contacts or temperature sensors and 4 led outputs. Digital inputs can interface sensors, traditional buttons, etc; 4 led output channels at low voltage can drive LED for synoptics panels or switches. Inputs 5 ÷ 8, set as analog inputs, can enable up to 2 tempera- ture probes (with On/Off threshold) and 2 thermostats to con- trol heating and cooling equipments, valves, 2 and 4 pipes fan coils; etc.. The device is equipped with appropriate communication inter- face with the bus type TP1 (twisted pair) KNX European stan- dard, according CEI EN 50090. Application Program See eelectron website : www.eelectron.com Maximum number of group addresses: 53 This is the maximum number of different group addresses the device is able to memorize. Maximum number of associations: 60 This is the maximum number of associations between com- munication objects and group addresses the device is able to memorize. Caution: each transmission object has usually associated a single group address. If you want to associate to a transmis- sion communication object other addresses in addition to the first, please note that you can add a maximum of 11 group ad- dresses of this kind for the whole device. Technical data Power Supply: Via bus EIB/KNX cable Voltage 21..30V DC Current Consumption EIB/KNX < 10mA Digital Input 1 – 2 – 3 - 4 For free potential contacts (dry contacts) Max. length of Connecting Cable: ≤ 30 m (twisted cable) Voltage Scanning: 3,3 V DC (internally Generated) AWG24 cables with 1800 mm length Digital Input 5 – 6 – 7 - 8 For free potential contacts (dry contacts) Max. length of Connecting Cable: ≤ 10 m (twisted cable) Voltage Scanning: 3,3 V DC (internally Generated) 6 poles terminal with screws. Analog Input 5 – 6 – 7 - 8 For NTC temperature probe eelectron code TS01A01ACC (range from -20°C to +100°C) TS01B01ACC (range from -50°C to +60°C) Max. length of Connecting Cable: ≤ 20 m (twisted cable) 6 poles terminal with screws. Digital Led Output 9 – 10 – 11 -12 4 outputs for drive led – Max 0,3 mA For LED eelectron code LD00A01ACC or LD00A11ACC AWG24 cables with 1800 mm length Control Elements EIB/KNX Red LED and button Mechanical Data • Case: plastic • Protection class: II in accordance with EN 61140 • Dimensions: (width x height. X depth.): 43 x 36 x 24 mm • Weight: approx. 35 g Electrical Diagram Electrical Safety • Degree of pollution (IEC 60664-1): 2 • Degree of protection (EN 60529): IP 20 • Protection class (according to IEC 1140): III • Overvoltage class (according to IEC 664-1): III • Bus: safety voltage SELV DC 21…31 V dc • Meets EN 50090 and IEC 664-1: 1992 EMC Requirements Complied with EN 50081-1, EN 50082-2 and EN 50090-2.2 Terms of use • According to EN 50090-2.2 • Ambient temperature during operation: 0 °C + 45 °C • Storage temperature: - 20 °C + 55 °C • Relative humidity: max 90% CE Mark According to EMC guideline and low voltage directive Indicators and Control Elements Wired Connectors: 1. BLACK COMMON IN/OUT 1 2. WHITE IN 1 3. YELLOW OUT 1 4. BLACK COMMON IN/OUT 2 5. RED IN 2 6. ORANGE OUT 2 7. BLACK COMMON IN/OUT 3 8. GREEN IN 3 9. BLUE OUT 3 10. BLACK COMMON IN/OUT 4 11. VIOLET IN 4 12. GREY OUT 4 13. - IN / TEMPERATURE SENSOR 5 14. - IN / TEMPERATURE SENSOR 6 15. - COMMON 5-6 16. - IN / TEMPERATURE SENSOR 7 17. - IN / TEMPERATURE SENSOR 8 18. - COMMON 7-8 19. - ETS PROGRAMMING SWITCH 20. - ETS PROGRAMMING LED 21. - EIB/KNX CONNECTOR - BLACK BUS NEGATIVE + RED BUS POSITIVE Installation Instructions The device may be used for permanent indoor installations in dry locations within wall box mounts. WARNING Device must be installed keeping a minimum distance of 4mm between electrical power line (mains) and in- put cables or red / black bus cable . The device must not be connected to 230V cables The prevailing safety rules must be heeded. The device must be mounted and commissioned by an authorised installer. The applicable safety and accident prevention regulations must be observed. The device must not be opened. Any faulty devices should be returned to manufacturer. For planning and construction of electric installations, the relevant guidelines, regulations and standards of the re- spective country are to be considered. Mounting and wiring hints General Description The device configuration (KNX physical address assignment) is done by pressing the programming push button. Please take care during installation to leave connection wires long enough in order to remove the device easily from the wall box for commissioning. Connecting bus cables Connect each single KNX/EIB bus core inside the termi- nal block observing bus polarity . Slip the bus connection block into the guide slot placed on the back side of this device and press the block down to the stop. Temperature probes TS01A01ACC Dimensions in millimetres NTC resistence tolerance: ± 3% Measure range -20°C ÷ +100°C Cable: 2 wire single insulation Cable colour: Black NTC colour: Black Warning: keep at least 6 mm from all live parts TS01B01ACC D1 = 9 mm D2 = 4 mm L2 = 49 mm L1 = 1250 mm NTC resistence tolerance: ± 2% Measure range -50°C ÷ +60°C Cable: 2 wire double insulation Cable colour: White NTC colour: White Warning: keep at least 3 mm from all live parts For further information please visit www.eelectron.com eelectron spa Via Magenta 77/22 I-20017 Rho (MI) - Italia Email: [email protected] Web: www.eelectron.com
Similar Manuals in the Control Unit, I/O Systems Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
WAGO 750-8 Series |
WAGO I/O Systems Manual (File: PDF, 25-04-2026) |
22 | 1409 | 282 | 25-04-2026 | view all manuals | |
Acromag BusWorks 900EN Series |
BusWorks 900EN Series Operation & user’s manual - E3KGTJ |
41 | 1288 | 258 | 05-08-2026 | view all manuals | |
Keysight M9187A |
#YQ1G9G: M9187A I/O Systems Startup manual |
32 | 1038 | 177 | 24-08-2026 | view all manuals | |
Digilent Basys MX3 |
Basys MX3 Reference manual - IQEV14 |
56 | 698 | 112 | 05-07-2026 | view all manuals | |
Autonics ARM Series |
User Guide: Autonics ARM Series (32MJ1H, Upd.31-05-2026) |
28 | 1451 | 334 | 31-05-2026 | view all manuals | |
Bentel Security FC410MIO |
User Guide: Bentel Security FC410MIO (ZTL82L, Upd.09-07-2026) |
4 | 1020 | 184 | 09-07-2026 | view all manuals |