ENSA ENSA-PS1 Manuals
1 pdf manual(s) ENSA ENSA-PS1 for free download (Document Types: Instruction manual)
ENSA ENSA-PS1 Instruction manual [PDF] (2 pages)
- Identifier: id-848900
- Brand: ENSA
- Device: ENSA ENSA-PS1 Switch
- Type: Instruction manual, PDF
- Key Aspects: Best Practices for Everyday Use, Emergency Shutdown Procedures, Risk Mitigation and Accident Prevention
- UPD Date: 21.03.2026
- Source File: 895676.pdf
- Pages: 2
- Description: Step-by-step user manual for the ENSA ENSA-PS1.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
ENSA-PS1 PASSIVE INFRARED OUTDOOR MOTION ACTIVATED SWITCH INSTRUCTION MANUAL www.ensalife.com Thanks for choosing the ENSA-PIR1 Passive Infrared Sensor! This product is an automated motion activated switch. It is based around a high sensitivity pyroelectric detector, light sensor and control electronics. The switch will turn on when it detects movement inside the detection area and stay on until a preset time has elapsed. The sensor will only switch the load on when the measured LUX level is below a set threshold. For installation only by a qualified Electrician – IP65 RATED FOR OUTDOOR USE SPECIFICATIONS: AC Input: 220-240VAC Detection Range: 180° Power Frequency: 50Hz Detection Distance: 12m max(<24℃) Ambient Light: <3-2000LUX (adjustable) Working Temperature: -20~+40℃ Time Delay: Min.10sec±3sec Working Humidity: <93%RH Max.7min±2min Power Consumption: approx 0.5W Rated Load: Max.1200W Installation Height: 1.8-2.5m 300W Detection Moving Speed: 0.6-1.5m/s FEATURES: Built in light sensor which can be set to detect between 3 lux (“moon” position) and 2000 lux (“sun” position). Time–Delay before load switch off is adjustable between 10 seconds and 7 minutes. Time delay before switch off is automatically reset when the sensor detects movement, even if the load is still on. This means that intermittent movement will keep the load on. LUX sensing is disabled while the load is on – This stops switched lights from triggering the lux sensor and turning themselves off. Wide angle PIR Fresnel lens can be tilted to the best position for optimum sensitivity. INSTALLATION ADVICE: To ensure the best detection range, mount the sensor in a position where people will walk across the detection field, rather than toward it Good sensitivity Poor sensitivity
Similar Manuals in the Switch Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
MiLAN MIL-SM8002TG |
MiLAN MIL-SM8002TG User Guide (Quick installation manual), @F5CLJC |
7 | 1330 | 266 | 12-06-2026 | view all manuals | |
Cisco TelePresence Server 7010 |
Cisco TelePresence Server 7010 Manual (Replacement instructions manual), @27RV62 |
22 | 0.32 Mb | 958 | 183 | 09-08-2026 | view all manuals |
Allied Telesis AT-8350GB |
Switch #25S7TA |
104 | 1.61 Mb | 1202 | 205 | 20-05-2026 | view all manuals |
C-Data FD1204S |
PDF User Manual (@DF3M9Y), C-Data FD1204S Network Hardware (18-03-2026) |
40 | 881 | 194 | 18-03-2026 | view all manuals | |
Lindy 39639 |
39639 Manual - 85S91Y |
2 | 1052 | 242 | 31-03-2026 | view all manuals | |
Ubiquiti NanoSwitch N-SW |
#776LW6: NanoSwitch N-SW Switch Quick start manual |
20 | 524 | 131 | 19-03-2026 | view all manuals |