fafnir CONDURIX Series Manuals
1 pdf manual(s) fafnir CONDURIX Series for free download (Document Types: Technical documentation manual)
Available Documents for CONDURIX Series:
Brand: fafnir
Model: CONDURIX Series
Format: PDF
Key Aspects: Technical Support and Resource Links, Warranty and Service Information, Error Code Explanations
Updated: 02.05.2026
Source File: 1612377.pdf
Pages: 24
Description: Professional operation guide for the fafnir CONDURIX Series.
Contents
Document Preview & Text Transcription
FAFNIR GmbH • Schnackenburgallee 149 c • 22525 Hamburg, Germany • Tel.: +49 / 40 / 39 82 07–0 • Fax: +49 / 40 / 390 63 39
Technical Documentation
CONDURIX
The potentiometric level sensor
Edition:
2016-08
Version:
9
Art. no.:
207134
I
Table of Contents
Table of Contents
II
Table of contents
1
Range of application .............................................................................. 1
2
Safety instructions ................................................................................. 2
3
Design and function ............................................................................... 3
4
Installation .............................................................................................. 5
4.1
CONDURIX Mono (single rod) ............................................................................. 6
4.2
CONDURIX DU (two rods) ................................................................................... 6
4.3
CONDURIX MA (jacketed pipe) ........................................................................... 6
5
Electrical connection .............................................................................. 7
6
Parametrisation ...................................................................................... 9
6.1
Measuring span at the level sensor ..................................................................... 9
6.2
Current consumption in failure mode ............................................................... 10
7
Maintenance ......................................................................................... 11
7.1
Overhaul .......................................................................................................... 11
7.2
Return shipment ............................................................................................... 11
8
Technical Data ...................................................................................... 12
9
List of figures ........................................................................................ 13
10
Annex .................................................................................................... 14
10.1
EC Declaration of Conformity ........................................................................... 14
10.2
EC-Type Examination Certificate ....................................................................... 15
10.3
Safety instructions ............................................................................................ 18
© Copyright:
Reproduction and translation are permitted only with the written consent of the FAFNIR GmbH. FAFNIR GmbH reserves
the right to make changes to products without prior notice.
Page 1/20
Range of application
1
Range of application
The purpose of the CONDURIX level sensor is to provide continuous level gauging of elec-
trically conductive liquids (> 1 μS/cm). During the measurement no insulating layer must
be formed on the probe tube.
The level sensor is available in lengths of 200 to 6,000 mm.
With the “single-rod probe” model (CONDURIX Mono), the inside of the container must
have a conductive surface (metal containers / downpipes). The “two-rod probe” model
(CONDURIX DU) or “jacketed probe” model (CONDURIX MA) are both compatible with
non-conductive containers.
The standard sensors work by outputting the measured fill level as an analogue value in
the range 4 to 20 mA.
With the HART option, the configuration and retrieval of measured values by the digital
HART protocol are supported, see
•
Technical Documentation CONDURIX with HART protocol, art. no. 350044
In conjunction with the standard level sensors, wetted parts are in stainless steel 1.4571
(316Ti), insulators are in PEEK (alternatively in PTFE). On request, the probe tubes are also
available in Hastelloy, tantalum, titanium or stainless steel 1.4404 (316L).