Fluidwell F113-A Manuals
Fluidwell F113-A Operation manual (48 pages)
- Identifier: id-1510632
- Brand: Fluidwell
- Device: Measuring Instruments
- Type: Operation manual, PDF
- Key Aspects: Maintenance Schedule, Device Configuration Guide
- UPD Date: 03.05.2026
- Source File: 1487797.pdf
- Pages: 48
- Description: Instruction and usage manual for the Fluidwell F113-A. It provides guidance on testing procedures, component overview, service procedures, supported accessories.
Key Pages and Contents:
-
OVERVIEW FUNCTIONS SETUP LEVEL
SETUP FUNCTIONS AND VARIABLES 1 TOTAL 11 UNIT L - m3 - kg - lb - GAL - USGAL - bbl - no unit 12 DECIMALS 0 - 1 - 2 - 3 (Ref: displayed value) 13 SPAN 0.000001 - 999,999 unit/second 14 DECIMALS SPAN 0 - 6 2 FLOWRATE 21 UNIT mL - L - m3 -
Mounting, electrical installation, start-up and maintenance of this instrument may only be
carried out by trained personnel authorized by the operator of the facility. Personnel must read and understand this Operating Manual befor -
VOLTAGE SELECTION SENSOR SUPPLY
For Intrinsically Safe applications: read chapter 5. Type PL Not applicable as the F110-A-PL is powered by the sensor signal. Type PB / PC / PX (AP) - battery powered and output loop-powered applications: Terminal 11 provides a limited -
Mounting, electrical installation, start-up and maintenance of the instrument may only be
carried out by trained personnel authorized by the operator of the facility. Personnel must read and understand this Operating Manual before
Fluidwell F113-A Manual (52 pages)
- Identifier: id-1991953
- Brand: Fluidwell
- Device: Measuring Instruments
- Type: Manual , PDF
- Key Aspects: Settings Configuration Instructions, Energy Efficiency Tips
- UPD Date: 05.08.2026
- Source File: 2295905.pdf
- Pages: 52
- Description: Complete usage guide for the Fluidwell F113-A. The guide provides instructions on setup validation, operating modes, component replacement, menu navigation.
Key Pages and Contents:
-
Type PB / PC / PX
3V DC for low power pulse signals and 1.2V DC for coil pick-up. Type PD 1.2; 3; 8.2; 12; 24V DC - max. 50mA@24V DC Type PD-XI Intrinsically ally safe: Pulse signals: 1.2; 3; 8.2 - max. [email protected] DC. Type PF / PM 1.2; 3; 8.2; 12; -
(requires type AP, OR and PD).
Type OT Three passive transistor outputs - not isolated. Load: max. 50V DC - 300mA 18BCommunication option Protocol bus-rtu; bus-asc Speed 1200; 2400; 4800; 9600 Addressing 1 - 247 Type CB RS232 Type CH RS485 2-wire Type CI RS485 4-wir -
ABOUT THE MANUAL
This manual is divided into two main sections: ▪ The daily use of the unit is described in chapter 2 "Operation". These instructions are meant for users. ▪ The following chapters and appendices are exclusively meant for electricians/technicians. -
A passive 4-20mA signal proportional to the flow rate is available with this option. When a power
supply is connected but the output is disabled, a 3.5mA signal will be generated. Max. driving capacity 1000 Ohm. This output does loop power the unit as well.
Fluidwell F113-A Installation manual (16 pages)
- Identifier: id-2203311
- Brand: Fluidwell
- Device: Security System
- Type: Installation manual, PDF
- Key Aspects: Guidelines for Regular Maintenance, Troubleshooting Information, Testing and Quality Assurance Processes
- UPD Date: 07.04.2026
- Source File: 2084321.pdf
- Pages: 16
- Description: Official operating instructions for the Fluidwell F113-A. This guide describes operating modes, operation, maintenance.
Key Pages and Contents:
-
Terminal 26-31: type CB / CH / CI / CT - communication RS232 / RS485 / TTL (option)
▪ Full serial communications and computer control in accordance with RS232 (length of cable max. 15 meters) or RS485 (length of cable max. 1200 meters) is possible. � -
Safety instructions .............................................................................................................................. 2
Disposal of electronic waste ............................................................ -
Fig. 2: GRP enclosures - Dimensions
75 mm (2.95") 130 mm (5.12") 112 mm (4.40") 60 mm (2.36") 120 mm (4.72") HD HK HK back box: (flat bottom) HE HF HG HH D=12mm 12mm 12mm 24mm 24mm 36mm 36mm 14mm 17mm 22,5mm 30mm 30mm D=16mm D=20mm 0.9" D=22mm (0.866") 2
Fluidwell F113-A Operation manual (49 pages)
- Identifier: id-1285703
- Brand: Fluidwell
- Device: Touch Panel
- Type: Operation manual, PDF
- Key Aspects: Usage Recommendations Under Different Conditions, Updates on New Features
- UPD Date: 17.04.2026
- Source File: 1301999.pdf
- Pages: 49
- Description: Detailed operating instructions for the Fluidwell F113-A. This documentation provides step-by-step guidance on operating guidelines, setup instructions, troubleshooting guides.
Key Pages and Contents:
-
Label information (inside and outside the enclosure)
Indicated labels on the back cover (below) and on the inside cover (right) show the type labels for intrinsically safe certified units. For details on usage see the separate “Fluidwell F1..-..-IX Documentation for -
EXPLANATION OF SETUP-FUNCTIONS
1 - TOTAL UNIT 11 SETUP 11 determines the measurement unit for total, accumulated total and pulse output. The following units can be selected: L; m3; kg; lb; GAL; USGAL; bbl; no unit Alteration of the measurement unit will have con -
The analog output value can be programmed “up-side-down” if desired,
so 4mA at maximum flowrate for example! CUT-OFF 74 To ignore leakage of the flow for example, a low flow cut-off can be set as a percentage of the full range of 16mA (or 20mA / 10V). When the flow -
Fig. 14: Configuration example 1 Intrinsically Safe
TERMINAL CONNECTORS F100-series HAZARDOUS AREA 3 4 9 10 11 Common ground Common ground Common ground Signal Supply * Main supply Circuit depends on type of signal Power supply type PD: 16-30V
F113-A: Related Instructions from Other Manufacturers
-
Exmark FR524 Lawn and Garden Equipment Operator's manual
28 -
Russound IBRIDGE POWERDOCK Other Datasheet
2 -
Haier HW-18CM03 Air Conditioner Operation manual
15 -
Tektronix 2445 Test Equipment Instruction manual
52 -
Argox PT Barcode Reader Quick reference manual
16 -
Panasonic AG-AF100A Camcorder Manual
19