Hussmann C2X-LE Manuals

3 pdf manual(s) Hussmann C2X-LE for free download (Document Types: Quick reference, Technical data sheet)

Available Documents for C2X-LE:

Hussmann C2X-LE Quick reference Main Page Preview

Quick reference [PDF] (10 pages)

  • Brand: Hussmann
  • Model: C2X-LE
  • Format: PDF
  • Key Aspects: Critical Operational Precautions, Pre-Installation Safety Requirements, Technical Data and Parameters
  • Updated: 30.06.2026
  • Source File: 461903.pdf
  • Pages: 10
  • Description: Instructions for safe usage of the Hussmann C2X-LE.

Document Preview & Text Transcription

IMPACT Quick Reference Data Discharge Air Temp °F Evaporator Temp °F* Low Pressure Cut In/Cut Out (With Thermostat) (°F) Defrost Frequency Hrs. Failsafe Off Time Duration Min. ** Temp Term °F 27 21 17/7 6 30 48 29 21 17/7 6 30 48 28 21 17/7 6 45 48 30 21 14/4 6 30 48 29 21 14/4 6 30 48 29 21 14/4 4 30 48 CONVERTIBLES C2E C2LE C2LGE C2XE C2XLE C2XLGE C2XGE C4LE C4LGE C5LE C5E C5GE C5HE C5LE C6E C6GE C6HE CGLE Recommended Control Settings (See installation instructions for complete information) CW2GE CW2XGE CW2UGE CW2EGE CW2XGE CW2UXGE CW2EXGE C3LGE *For temperature pressure controlled cases, cutout pressure must produce listed evaporator temperature. Differential should preserve product integrity while preventing compressor short cycling. **For temperature pressure termination, set termination control to terminate defrost when evaporator temperature reaches 48 degrees F except when othewise listed. Use for non-critical temperature cases only. NOTE: Reverse air defrost is not recommended for any Impact Merchandiser except M1LGE. Discharge Air Temp °F Evaporator Temp °F* Low Pressure Cut In/Cut Out (With Thermostat) (°F) Defrost Frequency Hrs. Failsafe Off Time Duration Min. ** Temp Term °F 31 21 14/4 6 30 48 32 24 17/7 6 35 48 31 21 14/4 6 35 48 32 24 17/7 6 35 48 32 24 17/7 6 40 48 31 21 14/4 6 35 48 DAIRY/DELI D5 D5L D5R D5LR D5HR D5E D5LE D5RE D5LRE D5GE D5NHE D5NGE D5NLGE D6G D6H Recommended Control Settings (See installation instructions for complete information) D5G D5H D5HE D5HRE D5NLE D5NE *For temperature pressure controlled cases, cutout pressure must produce listed evaporator temperature. Differential should preserve product integrity while preventing compressor short cycling. **For temperature pressure termination, set termination control to terminate defrost when evaporator temperature reaches 48 degrees F except when othewise listed. Use for non-critical temperature cases only. NOTE: Reverse air defrost is not recommended for any Impact Merchandiser except M1LGE. 32 24 17/7 6 40 48 31 21 14/4 6 30 48 D6GE D6HE D6 D6L 32 24 17/7 6 35 48 D6E D6LE 32 24 17/7 6 35 48 D5ELE D5EE
Hussmann C2X-LE Technical data sheet Main Page Preview

Technical data sheet [PDF] (8 pages)

  • Brand: Hussmann
  • Model: C2X-LE
  • Format: PDF
  • Key Aspects: Periodic Inspection Checklists, Initial Startup Checklist, Technical Data and Parameters
  • Updated: 29.07.2026
  • Source File: 461915.pdf
  • Pages: 8
  • Description: Device maintenance guide for the Hussmann C2X-LE.

Document Preview & Text Transcription

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. B A D E F F E C F P/N 0398675D Merchandisers ® Note: Changed items have been underlined. C2-XLE Technical Data Sheet P/N 0398675D NSF® Certified February 2006 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. Item Part # Description Wiring Item # FAN ASSEMBLIES AND THERMOSTATS A. 6W Fan Assembly (1) 0058698 Fan Motor, Evaporator 0142780 Fan Blade embossing toward motor B. 0311588 Standard Non-adjustable (2) Defrost Thermostat C. 0137880 Optional Adjustable (3) Refrigeration Thermostat Item Part # Description Wiring Item # HEATERS D. Canopy Anti-Sweat Heater (4) NA 4 ft 0109417 6 ft 0109417 8 ft 0109418 12 ft LAMPS AND BALLASTS E. Ballast, Electronic (5) 0376409 2 lamps 0376410 3 lamps F. Fluorescent Lamp (6) Replace with like fixtures Revision D corrects statistical data on Page 3. 2 of 8 C2-XLE Technical Data Sheet HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Engineering Plan Views B C 72 1/4 (1835) Elec. Waste Outlet 4 (102) 34 5/8 (881) 46 1/2 (1182) 38 7/8 (98 6) 29 1/4 (743) 30 5/8 (778) D 27 5/8 (703) Refrig. A Water Seal (see note) C2XLE 7 3/4 (199) Skid/ External Base Front Dimensions shown as inches and (mm). Dairy / Delicatessen Precut & Packaged Produce 05-2003 4 ft 6 ft 8 ft 12 ft General (A) Case Length (without ends or partitions) 48 1/4 (1226) 72 3/8 (1838) 96 3/8 (2448) 144 1/2 (3670) (Each end and insulated partition adds 1 1/2 in.(38 mm) to case line up.) Maximum O/S dimension of case back to front (includes bumper) 46 1/2 (1182) 46 1/2 (1182) 46 1/2 (1182) 46 1/2 (1182) Back of case to front of splashguard 38 7/8 (986) 38 7/8 (986) 38 7/8 (986) 38 7/8 (986) Back of case to O/S edge of front skid rail 29 1/4 (743) 29 1/4 (743) 29 1/4 (743) 29 1/4 (743) Width of skid rail 4 1/2 (114) 4 1/2 (114) 4 1/2 (114) 4 1/2 (114) RH end of case to outside edge of external support 5 1/2 (140) 5 1/2 (140) 5 1/2 (140) 5 1/2 (140) Distance between edges of external and center supports NA 31 1/8 (790) 40 5/8 (1032) 40 5/8 (1032) Distance between edges of center supports 41 1/4 (1048) NA NA 44 (1118) Stub-up area between front skid rail and splashguard 7 3/4 (199) 7 3/4 (199) 7 3/4 (199) 7 3/4 (199) Electrical Service (Electrical Field Wiring connection point) (B) RH End of case to center of farthest knockout 38 1/4 (972) 64 3/8 (1635) 88 3/8 (2245) 136 1/2 (3467) Back O/S of case to center of knockout 34 5/8 (881) 34 5/8 (881) 34 5/8 (881) 34 5/8 (881) Length of electrical raceway 16 1/8 (410) 34 1/2 (876) 35 5/8 (903) 35 5/8 (903) Waste Outlet (C) RH End of case to the center of waste outlet 24 1/8 (613) 24 1/8 (613) 24 1/8 (613) 72 1/4 (1835) LH End of case to the center of waste outlet 24 1/8 (613) 48 1/4 (1226) 72 1/4 (1835) 72 1/4 (1835) Water Seal Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) 4 (102) Outside diameter of the drip pipe 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) Note: Water seal outlet must clear front skid rail. Refrigeration Outlet Back of case to center of refrigeration outlet 30 5/8 (778) 30 5/8 (778) 30 5/8 (778) 30 5/8 (778) (D) RH end of case to center of refrigeration outlet 9 (230) 9 (230) 9 (230) 9 (230) REFRIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H. C2-XLE Discharge Air (°F) 29 Evaporator (°F) 21 Unit Sizing (°F) 19 Btu/hr/ft* C2-XLE Parallel 1177 Conventional 1260 *For all refrigeration equipment other than Hussmann, use conventional Btu values. DEFROST DATA C2-XLE Frequency (hr) 6 Defrost Water (lb/ft/day) 6 (± 15% based on case configuration and product loading). OFFTIME C2-XLE Temp Term (°F) 48°F Failsafe (minutes) 30 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise: close 48°F — open 33°F CONVENTIONAL CONTROLS Low Pressure Backup Control C2-XLE CI/CO** 17°F / 7°F Indoor Unit Only, Pressure Defrost Termination** 48°F **Use a Temperature Pressure Chart to determine PSIG conversions. PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1/2 Merchandiser Liquid Line (in.) 3/8 Merchandiser Suction Line (in.) 7/8 Estimated Charge (lb)*** 4 ft 1.3 6 ft 1.8 8 ft 2.3 12 ft 3.3 ***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound. 3 of 8 P/N 0398675D HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. 6 1/8 (155) (Note:* Optional Accessory Items) C2XLE 5 3/8 (136) 46 1/2 (1182) 38 7/8 (986) 34 5/8 (881) 30 5/8 (778) 29 1/4 (743) 27 5/8 (703) 7 3/4 (199) 19 (483) (Note*) (Note*) (Note*) (Note*) (Note*) 30 1/2 (775) 18 (457) 18 (457) 55 1/8 (1400) 30 1/2 (775) 12 (305) 3 3/4 (95) 19 (483) FAN C O I L 14 1/8 (359) Dimensions shown as inches and (mm). Multi-deck, 4 Display Levels NSF Certification These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF ®) Standard #7 requirements. Impact C2-XLE Dairy / Delicatessen Precut & Packaged Produce C2-XLE 4 of 8 C2-XLE Technical Data Sheet HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Impact C2-XLE Dairy / Delicatessen Precut & Packaged Produce Electrical Data 4 ft 6 ft 8 ft 12 ft Number of Fans 1 2 2 3 Amperes Watts 4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft Evaporator Fan 120V 60Hz Standard 0.51 1.00 1.00 1.50 38 78 78 117 120V 50Hz Standard 0.55 1.10 1.10 1.65 42 84 84 126 230V 60Hz Export 0.25 0.50 0.50 0.75 40 80 80 120 230V 50Hz Export 0.28 0.56 0.56 0.84 44 88 88 132 120V 60Hz Energy Efficient 0.26 0.52 0.52 0.78 18 36 36 54 230V 60Hz Energy Efficient NA Canopy Anti-sweat Heaters NA 0.75 0.75 1.00 45 90 90 120 Minimum Circuit Ampacity 120V 60Hz Standard 0.71 1.95 1.95 2.70 120V 50Hz Standard 0.75 2.05 2.05 2.85 230V 60Hz Export 0.45 1.45 1.45 1.95 230V 50Hz Export 0.48 1.51 1.51 2.04 120V 60Hz Energy Efficient 0.46 1.47 1.47 1.98 230V 60Hz Energy Efficient NA Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting 1 Row Canopy 0.26 0.51 0.51 0.77 30 59 59 85 Optional Lighting Additional 1 Row Canopy 0.26 0.51 0.51 0.77 30 59 59 85 Additional 2 Row Canopy 0.51 1.02 1.02 1.54 59 118 118 170 1 Row Rail Light 0.26 0.51 0.51 0.77 30 59 59 85 1 Row Ledge Light 0.26 0.51 0.51 0.77 30 59 59 85 Optional Shelf Lighting 1 Row Shelf Receptacle 0.26 0.51 0.51 0.77 30 59 59 85 2 Row Shelf Receptacle 0.51 1.02 1.02 1.53 59 118 118 177 115V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 230V Lighting Circuit Total = Multiply 115V Lighting Circuit Total by 0.52
Hussmann C2X-LE Technical data sheet Main Page Preview

Technical data sheet [PDF] (10 pages)

  • Brand: Hussmann
  • Model: C2X-LE
  • Format: PDF
  • Key Aspects: Additional Modules and Accessories Guide, System Connectivity and Wiring Basics, Model Variations and Compatibility
  • Updated: 04.06.2026
  • Source File: 461911.pdf
  • Pages: 10
  • Description: Stepwise user guide for the Hussmann C2X-LE.

Document Preview & Text Transcription

P/N 0486794_C B E C F E F A F D G H C2NX-XLE Technical Data Sheet P/N 0486794_C NSF® Certified March 2008 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. Item Part # Description Wiring Item # FAN ASSEMBLIES 4 Ft, 8 Ft & 12 Ft A. 7W Standard Fan Assembly (1) 0058698 Fan Motor, Evaporator (MO.4410102) 0142780 Fan Blade (FB.0142780) 7W Energy Efficient Fan Assembly (1) 0477654 Fan Motor, Evaporator (MO.4410545) 0142780 Fan Blade (FB.0142780) 6 Ft Only A. 4W Standard Fan Assembly (1) 0392457 Fan Motor, Evaporator (MO.4410101) 0382383 Fan Blade (FB.4780617) 4W Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator (MO.4410544) 0382383 Fan Blade (FB.4780617) THERMOSTATS B. 0411744 Standard Non-adjustable (2) Defrost Thermostat (CT.0411744) Item Part # Description Wiring Item # THERMOSTATS (CONTINUED) C. Optional Adjustable Refrigeration Thermostat (3) HEATERS D. Canopy Anti-Sweat Heater (4) 0488621 4 ft (HE.4850616) 0488622 6 ft (HE.4850617) 0488623 8 ft (HE.4850618) 0488624 12 ft (HE.4850619) LAMPS. BALLASTS, LED FIXTURES AND POWER SUPPLY E. Ballast, Electronic (5) 0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677) F. Fluorescent Lamp (6) Replace with like fixtures G. 0501213 Power Supply (EP.4481861) (7) H. LED Fixture (8) Replace with like fixtures ©2008 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM Note: Revision C adds optional LED lighting (Pages 1, 3, 4, 8); adds capacity and weight (Page 5). Wireway 26 3/4 (680) 25 1/4 (641) 37 (940) A 41 1/2 (1054) 28 1/2 (724) 3 In. (77 mm) Required Air Gap Refrigeration Outlet Waste Outlet Waste Outlet FRONT 4 3/4 (120) 21 1/4 (540) D C 8 (203) 12 1/8 (307) 4 1/4 (108) 41 1/2 (1054) 43 7/8 (1114) B Splashguard 19 (483) NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD. Electrical Stub Up Area 6 x 6 (152x152) Electrical Field Connection 26 1/2 (673) 4 3/4 (120) 4 1/2 (115) 2 of 10 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. C2NX-XLE Technical Data Sheet Engineering Plan Views Dimensions shown as inches and (mm). Dairy/Delicatessen Precut & Packaged Produce 01-2005 C2NX 4 ft 6 ft 8 ft 12 ft General (A) Case Length (without ends or partitions) 48 3/8 (1229) 72 3/8 (1838) 96 3/8 (2448) 144 1/2 (3670) (Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.) Maximum O/S dimension of case back to front (includes bumper) 37 (940) 37 (940) 37 (940) 37 (940) Back of case to front of splashguard 28 1/2 (724) 28 1/2 (724) 28 1/2 (724) 28 1/2 (724) Back of case to O/S edge of front leg 25 1/4 (641) 25 1/4 (641) 25 1/4 (641) 25 1/4 (641) Distance between edges of external legs and center legs NA 29 1/2 (750) 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center legs NA NA NA 43 7/8 (1114) Distance between front legs and splashguard 2 3/4 (70) 2 3/4 (70) 2 3/4 (70) 2 3/4 (70) Electrical Service (Electrical Field Wiring connection point) (B) RH End of case to center of stub up area 36 1/4 (921) 60 1/4 (1530) 84 1/4 (2140) 132 3/8 (3363) Back of case to center of stub up area 19 (483) 19 (483) 19 (483) 19 (483) Length of electrical wireway 26 1/2 (673) 26 1/2 (673) 26 1/2 (673) 26 1/2 (673) (C) RH End of case to LH end of wireway 42 1/8 (1070) 66 1/8 (1680) 90 1/8 (2289) 138 1/4 (3511) Waste Outlets (One each end) (D) RH End of case to the center of LH waste outlet 36 1/4 (921) 60 1/4 (1530) 84 1/4 (2140) 132 3/8 (3363) RH End of case to the center of RH waste outlet 12 1/8 (307) 12 1/8 (307) 12 1/8 (307) 12 1/8 (307) Back O/S of case to center of waste outlets 26 3/4 (680) 26 3/4 (680) 26 3/4 (680) 26 3/4 (680) Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) Refrigeration Outlet Back of case to center of refrigeration outlet 21 1/4 (540) 21 1/4 (540) 21 1/4 (540) 21 1/4 (540) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203) 8 (203) PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1/4 Merchandiser Liquid Line (in.) 3/8 Merchandiser Suction Line (in.) 7/8 Wireway REFRIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H. C2NX-XLE Discharge Air °F 29 Evaporator °F 21 Unit Sizing °F 19 Btu/hr/ft — Unlit Shelves C2NX-XLE‡‡ Parallel Conventional UNLIT 1060 1135 ‡‡ Add 10 Btu/hr/ft per shelf row for LED fixtures. Add 20 Btu/hr/ft per shelf row for fluorescent lamps. DEFROST DATA C2NX-XLE Frequency (hr) 6 Defrost Water (lb/ft/day) 7 (±15% based on case configuration and product loading. OFFTIME C2NX-XLE Temp Term °F 48°F Failsafe Minutes 30 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise: close 48°F – open 33°F CONVENTIONAL CONTROLS Low Pressure Backup Control C2NX-XLE CI/CO* 14°F / 4°F Indoor Unit Only, Pressure Defrost Termination* 48°F *Use a Temperature Pressure Chart to determine PSIG conversions. Estimated Charge (lb)** C2NX-XLE 4 ft 1.2 6 ft 1.6 8 ft 2.3 12 ft 3.3 **This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound. Dimensions shown as inches and (mm). P/N 0486794_C 3 of 10 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM Refrigeration Outlet 55 3/4 (1415) 26 3/4 (680) 4 3/4 (120) 25 1/4 (641) 37 (940) 28 1/2 (724) 21 1/4 (540) C2NX-XLE 25 1/4 (641) 18 1/2 (470) FAN C O I L 17 1/4 (438) 3 In. (77 mm) Required Air Gap 19 5/8 (500) Electrical Case to Case Connections 12 1/4 (311) 3 5/8 (92) 36 (914) 30 1/2 (774) 3 3/4 (95) 4 7/8 (123) Impact Excel C2NX-XLE Dairy/Delicatessen Precut & Packaged Produce Multi-deck, 4 Display Levels, Low Front, 55 In. Back, Narrow Footprint NSF Certification This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability. See Page 9 for shelf arrangement.