Intermatic PG3000 Manuals

1 pdf manual(s) Intermatic PG3000 for free download (Document Types: Installation instructions and operating manual)

Intermatic PG3000 Installation instructions and operating manual Thumbnail

Intermatic PG3000 Installation instructions and operating manual [PDF] (4 pages)

  • Identifier: id-489687
  • Brand: Intermatic
  • Device: Intermatic PG3000 Protection Device
  • Type: Installation instructions and operating manual, PDF
  • Key Aspects: Information on Regular Maintenance, End-of-Life Handling and Disposal, Technical Data and Parameters
  • UPD Date: 29.07.2026
  • Source File: 475307.pdf
  • Pages: 4
  • Description: Official installation manual for the Intermatic PG3000.
Pages Preview:
  • Intermatic PG3000 Installation instructions and operating manual preview - page 2
  • Intermatic PG3000 Installation instructions and operating manual preview - page 3
  • Intermatic PG3000 Installation instructions and operating manual preview - page 4
Document Preview & Text Transcription (Main Page)
Click to expand and read text
INSTALLATION INSTRUCTIONS and OPERATIONS MANUAL TURN OFF POWER TO THE ELECTRIC SERVICE OR PANEL AND TO EQUIPMENT TO BE PROTECTED BEFORE INSTALLING ANY SURGE PROTECTION DEVICE. ALL WIRING SHOULD COMPLY WITH THE NATIONAL ELECTRIC CODE AND LOCAL ELECTRIC CODES. INSTALLATION 1. TEST and verify system voltage to assure proper selection of the Surge Protection Device (SPD) in accordance with the wiring diagrams shown on page 2. Turn OFF the electric power to the panel. 2. CONFIRM that the Surge Protection Device is the proper voltage configuration for this installation. Refer to the installation dia- grams for additional information. 3. SELECT a location to mount the SPD cabinet. Mount as close as possible to the electric panel or individual piece of equipment to be protected. The SPD should be mounted on a flat vertical surface that can support the weight of the device. Consideration should be given to the available knockout positions in the panel when deciding where to locate the SPD. All wire leads should be kept as short as possible to insure optimum operation. 4. The internal Ferraz Shawmut VSP fuses are the prime current protection devices for this SPD; but safety and good wiring practice suggests that lead wires be connected to a multi-pole breaker. Use a 60 to 100 amp breaker with the appropriate number of poles. Panel breakers will not trip from surge activity due to their inherent slow response. NOTE: For installations connecting directly to bus bar, the PG Series must be less than ten feet (10’) wire distance from the bus bar to qualify the internal fuses as the primary overcurrent device in accordance with the NEC 10 foot rule 240-21(b). MOUNTING 1. Attach the upper and lower mounting rails to the PG Series Cabinet using the screws provided. 2. Pre-drill holes in the surface on which the PG Series will be mounted. Use at least four (4) appropriate size mounting screws or bolts. 3. Open the hinged cover on the PG Series unit by unscrewing the locking bolts in the cover. 4. Remove the deadfront panel. 5. Select and remove the proper size knockout from the PG Series cabinet. Install conduit, sealtite or other proper wire protec- tion between the panel and the SPD. WIRING 1. Refer to the chart on page 2 for the proper wire size. 2. Measure and cut all leads to proper length, keeping in mind that leads should be as short and straight as possible. 3. Tie wrap or tape all wires together to minimize inductive coupling. 4. Route the wire lead bundle through the conduit to the panel. 5. Connect the GROUND (green) lead to the ground bus in both the PG Series and the electric panel. 6. If used, connect the NEUTRAL (white) to the neutral terminal in the PG Series and the neutral bus in the electric panel. If installing at the main distribution panel, the neutral and ground leads could terminate at a common bus bar in the panel. 7. Connect the phase leads to the proper connectors in the PG Series. Then connect them to the appropriate breaker connec- tions in the electric panel. NOTE: For HIGH LEG DELTA, make certain that the high leg is connected to the designated position in the PG Series.(Refer to Figure 3) 8. Connect wires to the alarm relay leads. Alarm wires should be routed through a knockout that is separate from the power leads. (Refer to alarm wiring drawings on page 2) 9. CHECK all connections for tightness. 10. REPLACE Dead-front panel. 11. Close and secure the hinged front cover, remembering to replace all of the locking bolts. 12. Turn power to the unit ON. CAUTION:          

Similar Manuals in the Protection Device Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Overland Storage NEO Series

Overland Storage NEO Series User Guide (Installation instructions), @S4Z1V2

4 1119 235 01-04-2026 view all manuals
ABB Relion 620 Series

Relion 620 Series (Controller ePDF User Guide, #4V58E6)

60 952 229 22-08-2026 view all manuals
Littelfuse MPS

Protection Device #B938AM

148 752 136 08-04-2026 view all manuals
Textron GREENLEE 01761-03XL

Protection Device #85HR2E

2 606 122 03-05-2026 view all manuals
3M DBI SALA SEALED-BLOK 3400944

3M DBI SALA SEALED-BLOK 3400944 Guide (Instruction manual), @Z9Z4KR

24 1204 181 09-06-2026 view all manuals
GE D90 Plus

D90 Plus Instruction manual - SEIA9Q

694 645 162 04-08-2026 view all manuals