Klein Tools CL200 Manuals

2 pdf manual(s) Klein Tools CL200 for free download (Document Types: Instruction manual)

Available Documents for CL200:

Klein Tools CL200 Instruction manual Main Page Preview

Instruction manual [PDF] (4 pages)

  • Brand: Klein Tools
  • Model: CL200
  • Format: PDF
  • Key Aspects: System Architecture and Design Overview, Storage and Care Recommendations, Glossary of Technical Terms
  • Updated: 20.05.2026
  • Source File: 1160706.pdf
  • Pages: 4
  • Description: Installation instructions for the Klein Tools CL200.

Document Preview & Text Transcription

Instruction Manual Instruction Manual ENGLISH www.kleintools.com For Professionals...Since 1857 ® ENGLISH CL200 AUTO A AC CL200 • 3-3/4 DIGIT 3999 COUNT LCD • AUTO / MANUAL RANGE • DATA HOLD • BACKLIGHT • WORKLIGHT CL200 Instruction Manual General Specifications The Klein Tools CL200 is a multi-featured clamp meter. It measures AC / DC voltage, AC current, resistance, capacitance, frequency, duty cycle, and temperature. It can also test diodes and continuity. • Operating Altitude: 2000 meters • Relative Humidity: 75% max • Operating Temperature: 0°C / 32°F to 40°C / 104°F • Storage Temperature: -10°C / 14°F to 50°C / 122°F • Accuracy Temperature: 18°C / 64°F to 28°C / 82°F • Temperature Coefficient: 0.1*(specified accuracy) / °C • Sampling Frequency: 3 samples per second • Dimensions: 8.2" x 3.0" x 1.4" • Weight: 10.0 oz. • Calibration: Accurate for one year • CAT Rating: CAT III 600V • Accuracy: ± (% of reading + # of least significant digits) WARNINGS To ensure safe operation and service of the tester, follow these instructions. Failure to observe these warnings can result in severe injury or death. • Before each use, verify meter operation by measuring a known voltage or current. • Never use the meter on a circuit with voltages that exceed the category based rating of this meter. • Do not use the meter during electrical storms, or in wet weather. • Do not use the meter or test leads if they appear to be damaged. • Ensure meter leads are fully seated, and keep fingers away from the metal probe contacts when making measurements. • Do not open the meter to replace batteries while the probes are connected. • Use caution when working with voltages above 60V DC, or 25V AC RMS. Such voltages pose a shock hazard. • To avoid false readings that can lead to electrical shock, replace batteries if a low battery indicator appears. • Unless measuring voltage or current, shut off and lock out power before measuring resistance or capacitance. • Always adhere to local and national safety codes. Use individual protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed. SYMBOLS ~ AC Alternating Current Warning or Caution DC Direct Current Dangerous levels DC/AC Voltage or Current Double Insulated Class II Ground Safe for disconnect from live conductors AC Source ENGLISH H. Backlight / Worklight • Hold button down to enable worklight and backlight. • On release, lights will turn off automatically after 5 to 15 seconds. • Worklight only operates during AC current measurement. • Using lights drains the battery significantly. CL200 1 5 2 4 Function Instructions AUTO A AC CL200 1 B C 3 F A E D G H H A. Use CAT III rated leads or higher. Do not attempt to measure more than 600V or any current on lead input. B. Keep hands below line when measuring high current levels. C. Select Functionality Button • Switch between AC and DC. • Switch between Ω, , , and . D. Data Hold • Press to hold the current input on the display. • Press again to return to live reading. E. Auto / Manual Range • Press repeatedly to cycle through manual ranges. • Hold for 2 seconds to return to auto ranging mode. • AUTO is displayed on LCD only during auto ranging mode. F. G. Battery Replacement • When indicator is displayed on the LCD, batteries must be replaced. • Remove the back screw and replace 3 x AAA batteries. On Back 1. AC Current: < 600A Features: HOLD RANGE WORKLIGHT • Center wire in guides for best accuracy. • Opposing currents cancel (use line-splitter when necessary). 2. AC / DC Voltage: < 600V Features: HOLD RANGE • Select AC or DC voltage source. 3. Frequency (Hz) / Duty Cycle Features: HOLD PRESS AUTO A AC AUTO A AC PRESS Duty AUTO A AC Auto Power-Off • Device will power off after 30 minutes non-use. • Turn the dial or press a button to wake. • Press the HOLD button while turning on to disable Auto Power-Off feature. Feature Details ENGLISH Symbols used on LCD ~ AC Measurement DC Measurement - Negative DC Value AUTO Auto Range Active Low Battery A Current in Amps H Hold Active Diode Test V Voltage Measurement Continuity Test Hz Frequency in Hertz % Duty Cycle F Capacitance in Farads °F Temperature in Fahrenheit Ω Resistance in Ohms M Mega 106 m Milli 10-3 k Kilo 103 n Nano 10-9 μ Micro 10-6 • Display shows resistance. • Buzzer sounds if less than 60Ω Continuity Features: HOLD 4. Temperature: -4° ≤ °F ≤ 1832° Features: HOLD • Use included thermocouple. AUTO A AC AUTO A AC AUTO A AC AUTO A AC PRESS TO SELECT Diode Resistance Capacitance Continuity A AC • F < 100μF • Wait up to 60 seconds for measurement. • Safely discharge capacitor before measurement. Capacitance Features: HOLD RANGE Display shows: • Forward voltage drop if forward biased. • “O.L.” if reverse biased. Diode Features: HOLD • Ω < 40MΩ • Do not measure resistance on a live circuit. Resistance Features: HOLD RANGE 5. Resistance / Capacitance / Diode / Continuity Electrical Specifications DC Voltage Measurement Range Resolution Accuracy 400mV 0.1mV ± (0.8% + 2 digits) 4V 0.001V 40V 0.01V 400V 0.1V 600V 1V ± (1.0% + 2 digits) Overload Protection: 600V DC / AC Input Impedance: 10MΩ. AC Voltage Measurement Range Resolution Accuracy 400mV 0.1mV ± (1.0% + 10 digits) 4V 0.001V 40V 0.01V 400V 0.1V 600V 1V ± (1.2% + 10 digits) Overload Protection: 600V DC / AC Frequency: 40 to 400Hz Input Impedance: 10MΩ. Response: Averaging AC Current Measurement Range Resolution Accuracy 4A 0.001A ± (3.5% + 20 digits) ≤ 0.5A 4A 0.001A ± (3.0% + 10 digits) > 0.5A 40A 0.01A ± (3.0% + 10 digits) 400A 0.1A ± (2.5% + 10 digits) 600A 1A ± (1.5% + 5 digits) Overload Protection: 720A for 60 sec. max Frequency: 50 to 60Hz Response: Averaging Resistance Measurement Range Resolution Accuracy 400Ω 0.1Ω ± (1.2% + 2 digits) 4kΩ 0.001kΩ 40kΩ 0.01kΩ 400kΩ 0.1kΩ 4MΩ 0.001MΩ 40MΩ 0.01MΩ ± (2.0% + 5 digits) Overload Protection: 600V DC / AC 1-877-775-5346 www.kleintools.com 139560T CUSTOMER SERVICE KLEIN TOOLS, INC. 450 Bond Street Lincolnshire, IL 60069 1-877-287-6603 www.kleintools.com ENGLISH Warranty This product is warranted to be free from defects in materials and workmanship for a period of two years from the date of purchase. During this warranty period, Klein Tools has the option to repair or replace or refund the purchase price of any unit which fails to conform to this warranty under normal use and service. This warranty does not cover damage which occurs in shipment or failure which results from alteration, tampering, accident, misuse, abuse, neglect, or improper maintenance. Batteries and damage resulting from failed batteries are not covered by warranty. A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered. Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. Klein Tools shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss. Some states or countries laws vary, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. If your Klein product requires repair or for information on how to exercise your rights under the terms of this warranty, please contact Klein Tools at 1-877-775-5346. CLEANING Turn instrument off and disconnect test leads. Clean the instrument by using a damp cloth. Do not use abrasive cleaners or solvents. STORAGE Remove the batteries when instrument is not in use for a prolonged period of time. Do not expose to high temperatures or humidity. After a period of storage in extreme conditions exceeding the limits mentioned in the Specifications section, allow the instrument to return to normal operating conditions before using it. Disposal / Recycle Caution: This symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal. Capacitance Measurement Range Resolution Accuracy 50nF 0.01nF ± (3.0% + 10 digits) 500nF 0.1nF ± (3.0% + 5 digits) 5µF 0.001µF 50µF 0.01µF 100µF 0.1µF Overload Protection: 600V DC / AC Frequency Measurement Range Resolution Accuracy 50Hz 0.01Hz ± (0.1% + 3 digits) 500Hz 0.1Hz 5kHz 0.001kHz 50kHz 0.01kHz 100kHz 0.1kHz Overload Protection: 600V DC / AC Duty Cycle Measurement Range Resolution Accuracy 0.1 ˜ 99.9% 0.1% ± (3.0% + 0 digits) Overload Protection: 600V DC / AC Temperature Measurement Range Resolution Accuracy -4 ˜ 1832°F 1°F ± (3.0% + 3 digits) Overload Protection: 600V DC / AC Diode Test Overload Protection Resolution Open Circuit Voltage 600V DC / AC 1mV Appx. 1.5V Continuity Test Overload Protection Resolution Open Circuit Voltage 600V DC / AC 100mΩ Appx. 0.45V
Klein Tools CL200 Instruction manual Main Page Preview

Instruction manual [PDF] (6 pages)

  • Brand: Klein Tools
  • Model: CL200
  • Format: PDF
  • Key Aspects: Advanced Configuration Methods, Technical Data and Parameters, Additional Modules and Accessories Guide
  • Updated: 07.09.2026
  • Source File: 1074774.pdf
  • Pages: 6
  • Description: Advanced user manual for the Klein Tools CL200.

Document Preview & Text Transcription

CUSTOMER SERVICE KLEIN TOOLS, INC. 450 Bond Street Lincolnshire, IL 60069 1-877-775-5346 [email protected] www.kleintools.com 139560T Rev. 11/13 B ENGLISH • AUTO / MANUAL RANGE • DATA HOLD • 3-1/2 DIGIT 1999 COUNT LCD • BACKLIGHT • WORKLIGHT • TEMPERATURE ENGLISH ELECTRICAL SPECIFICATIONS DC Voltage Measurement Range Resolution Accuracy 400mV 0.1mV ± (0.8% + 2 digits) 4V 0.001V 40V 0.01V 400V 0.1V 600V 1V ± (1.0% + 2 digits) Overload Protection: 600V DC / AC Input Impedance: 10MΩ. AC Voltage Measurement Range Resolution Accuracy 400mV 0.1mV ± (1.0% + 10 digits) 4V 0.001V 40V 0.01V 400V 0.1V 600V 1V ± (1.2% + 10 digits) Overload Protection: 600V DC / AC Frequency: 40 to 400Hz Input Impedance: 10MΩ. Response: Averaging AC Current Measurement Range Resolution Accuracy 4A 0.001A ± (3.5% + 20 digits) ≤ 0.5A 4A 0.001A ± (3.0% + 10 digits) > 0.5A 40A 0.01A ± (3.0% + 10 digits) 400A 0.1A ± (2.5% + 10 digits) 600A 1A ± (1.5% + 5 digits) Overload Protection: 720A for 60 sec. max Frequency: 50 to 60Hz Response: Averaging Resistance Measurement Range Resolution Accuracy 400Ω 0.1Ω ± (1.2% + 2 digits) 4kΩ 0.001kΩ 40kΩ 0.01kΩ 400kΩ 0.1kΩ 4MΩ 0.001MΩ 40MΩ 0.01MΩ ± (2.0% + 5 digits) Overload Protection: 600V DC / AC Capacitance Measurement Range Resolution Accuracy 50nF 0.01nF ± (3.0% + 10 digits) 500nF 0.1nF ± (3.0% + 5 digits) 5µF 0.001µF 50µF 0.01µF 100µF 0.1µF Overload Protection: 600V DC / AC Frequency Measurement Range Resolution Accuracy 50Hz 0.01Hz ± (0.1% + 3 digits) 500Hz 0.1Hz 5kHz 0.001kHz 50kHz 0.01kHz 100kHz 0.1kHz Overload Protection: 600V DC / AC Duty Cycle Measurement Range Resolution Accuracy 0.1 ˜ 99.9% 0.1% ± (3.0% + 0 digits) Overload Protection: 600V DC / AC Temperature Measurement Range Resolution Accuracy -4 ˜ 1832°F 1°F ± (3.0% + 3 digits) -20 ˜ 1000°C 1°C ± (3.0% + 2 digits) Overload Protection: 600V DC / AC Diode Test Overload Protection Resolution Open Circuit Voltage 600V DC / AC 1mV Appx. 1.5V Continuity Test Overload Protection Resolution Open Circuit Voltage 600V DC / AC 100mΩ Appx. 0.45V WARRANTY www.kleintools.com/warranty CLEANING Turn instrument off and disconnect test leads. Clean the instrument by using a damp cloth. Do not use abrasive cleaners or solvents. STORAGE Remove the batteries when instrument is not in use for a prolonged period of time. Do not expose to high temperatures or humidity. After a period of storage in extreme conditions exceeding the limits mentioned in the Specifications section, allow the instrument to return to normal operating conditions before using it. DISPOSAL / RECYCLE Caution: This symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal. Dwg Name: CL200-139560TART Dwg No: 139560T ECO No: 15429 Pkg Dwg Ref: 1650 Rev: B Color Reference: N/A Instruction Manual CL200 600A 600V CL200 Instruction Manuals - MASTER.indd 1-4 12/16/2013 12:16:18 PM ENGLISH 1 B C 3 F A E D G H H A. Use CAT III rated leads or higher. Do not attempt to measure more than 600V or any current on lead input. B. Keep hands below line when measuring high current levels. C. Select Functionality Button • Switch between AC and DC. • Switch between Ω, , , and . D. Data Hold • Press to hold the current input on the display. • Press again to return to live reading. E. Auto / Manual Range • Press repeatedly to cycle through manual ranges. • Hold for 2 seconds to return to auto ranging mode. • AUTO is displayed on LCD only during auto ranging mode. F. G. Battery Replacement • When indicator is displayed on the LCD, batteries must be replaced. • Remove the back screw and replace 3 x AAA batteries. H. Backlight / Worklight • Hold button down to enable worklight and backlight. • On release, lights will turn off automatically after 5 to 15 seconds. • Worklight only operates during AC current measurement. • Using lights drains the battery significantly. 1 5 4 FUNCTION INSTRUCTIONS On Back 2 FEATURE DETAILS CL200 Instruction Manual GENERAL SPECIFICATIONS The Klein Tools CL200 is a multi-featured clamp meter. It measures AC / DC voltage, AC current, resistance, capacitance, frequency, duty cycle, and temperature. It can also test diodes and continuity. • Operating Altitude: 2000 meters • Relative Humidity: 75% max • Operating Temperature: 32°F ~ 104°F (0°C~ 40°C) • Storage Temperature: 14°F ~ 122°F (-10°C ~ 50°C) • Accuracy Temperature: 64°F ~ 82°F (18°C ~ 28°C) • Temperature Coeff cient: 0.1*(specified accuracy) / °C • Sampling Frequency: 3 samples per second • Dimensions: 8" x 3" x 1" (203 mm x 76 mm x 25 mm) • Weight: 10 oz. (283 g) • Calibration: Accurate for one year • Safety Rating: CAT III 600V • Accuracy: ± (% of reading + # of least significant digits) WARNINGS To ensure safe operation and service of the tester, follow these instructions. Failure to observe these warnings can result in severe injury or death. • Before each use, verify meter operation by measuring a known voltage or current. • Never use the meter on a circuit with voltages that exceed the category based rating of this meter. • Do not use the meter during electrical storms, or in wet weather. • Do not use the meter or test leads if they appear to be damaged. • Ensure meter leads are fully seated, and keep fingers away from the metal probe contacts when making measurements. • Do not open the meter to replace batteries while the probes are connected. • Use caution when working with voltages above 60V DC, or 25V AC RMS. Such voltages pose a shock hazard. • To avoid false readings that can lead to electrical shock, replace batteries if a low battery indicator appears. • Unless measuring voltage or current, shut off and lock out power before measuring resistance or capacitance. • Always adhere to local and national safety codes. Use individual protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed. SYMBOLS ~ AC Alternating Current Warning or Caution DC Direct Current Dangerous levels DC/AC Voltage or Current Double Insulated Class II Ground Safe for disconnect from live conductors AC Source 1. AC Current: < 600A Features: HOLD RANGE WORKLIGHT • Center wire in guides for best accuracy. • Opposing currents cancel (use line-splitter when necessary). 2. AC / DC Voltage: < 600V Features: HOLD RANGE SYMBOLS USED ON LCD ~ AC Measurement DC Measurement - Negative DC Value AUTO Auto Range Active Low Battery A Current in Amps H Hold Active Diode Test V Voltage Measurement Continuity Test Hz Frequency in Hertz % Duty Cycle F Capacitance in Farads °F Temperature in Fahrenheit Ω Resistance in Ohms M Mega 106 m Milli 10-3 k Kilo 103 n Nano 10-9 μ Micro 10-6 • Display shows resistance. • Buzzer sounds if less than 60Ω Continuity Features: HOLD • Select AC or DC voltage source. 3. Frequency (Hz) / Duty Cycle Features: HOLD 4. Temperature: -4° ~ 1832°F (-20° ~ 1000°C) Features: HOLD • Use included thermocouple. AUTO A AC AUTO A AC AUTO A AC AUTO A AC TO SELECT A AC PRESS AUTO A AC AUTO A AC ˚F ˚C PRESS Duty AUTO A AC ˚F ˚C • F < 100μF • Wait up to 60 seconds for measurement. • Safely discharge capacitor before measurement. Capacitance Features: HOLD RANGE Display shows: • Forward voltage drop if forward biased. • “O.L.” if reverse biased. Diode Features: HOLD • Ω < 40MΩ • Do not measure resistance on a live circuit. Resistance Features: HOLD RANGE 5. Resistance / Capacitance / Diode / Continuity Auto Power-Off • Device will power off after 30 minutes non-use. • Turn the dial or press a button to wake. • Press the HOLD button while turning on to disable Auto Power-Off feature. PRESS AC DC PRESS Hz Duty PRESS TO SELECT Resistance Diode Capacitance Continuity ~ A - N L H H V V Hz F F C Ω R m M n N Dwg Name: CL200-139560TART Dwg No: 139560T ECO No: 15429 Pkg Dwg Ref: 1650 Rev: B Color Reference: N/A CL200 Instruction Manuals - MASTER.indd 5-8 12/16/2013 12:16:21 PM SERVICIO AL CLIENTE KLEIN TOOLS, INC. 450 Bond Street Lincolnshire, IL 60069 1-877-775-5346 [email protected] www.kleintools.com 139561T Rev. 11/13 B ESPAÑOL • RANGO AUTOMÁTICO/ MANUAL • RETENCIÓN DE DATOS • PANTALLA LCD DE 3-1/2 DÍGITOS CON RECUENTO DE 1999 • RETRO- ILUMINACIÓN • LUZ DE TRABAJO • TEMPERATURA ESPAÑOL ESPECIFICACIONES ELÉCTRICAS Medición de voltaje CD Rango Resolución Precisión 400 mV 0,1 mV ± (0,8 % + 2 dígitos) 4 V 0,001 V 40 V 0,01 V 400 V 0,1 V 600 V 1 V ± (1,0 % + 2 dígitos) Protección contra sobrecarga: 600 V CD/CA Impedancia de entrada: 10 MΩ. Medición de voltaje CA Rango Resolución Precisión 400 mV 0,1 mV ± (1,0 % + 10 dígitos) 4 V 0,001 V 40 V 0,01 V 400 V 0,1 V 600 V 1 V ± (1,2 % + 10 dígitos) Protección contra sobrecarga: 600 V CD/CA Frecuencia: 40 Hz a 400 Hz Impedancia de entrada: 10 MΩ. Respuesta: Promedio Medición de corriente CA Rango Resolución Precisión 4 A 0,001 A ± (3,5 % + 20 dígitos) ≤ 0,5 A 4 A 0,001 A ± (3,0 % + 10 dígitos) ≤ 0,5 A 40 A 0,01 A ± (3,0 % + 10 dígitos) 400 A 0,1 A ± (2,5 % + 10 dígitos) 600 A 1 A ± (1,5 % + 5 dígitos) Protección contra sobrecarga: 720 A para 60 seg. máx. Frecuencia: 50 Hz a 60 Hz Respuesta: Promedio Medición de resistencia Rango Resolución Precisión 400 Ω 0,1 Ω ± (1,2 % + 2 dígitos) 4 kΩ 0,001 kΩ 40 kΩ 0,01 kΩ 400 kΩ 0,1 kΩ 4 MΩ 0,001 MΩ 40 MΩ 0,01 MΩ ± (2,0 % + 5 dígitos) Protección contra sobrecarga: 600 V CD/CA Medición de capacitancia Rango Resolución Precisión 50 nF 0,01 nF ± (3,0 % + 10 dígitos) 500 nF 0,1 nF ± (3,0 % + 5 dígitos) 5 µF 0,001 µF 50 µF 0,01 µF 100 µF 0,1 µF Protección contra sobrecarga: 600 V CD/CA Medición de frecuencia Rango Resolución Precisión 50 Hz 0,01 Hz ± (0,1 % + 3 dígitos) 500 Hz 0,1 Hz 5 kHz 0,001 kHz 50 kHz 0,01 kHz 100 kHz 0,1 kHz Protección contra sobrecarga: 600 V CD/CA Medición de ciclo de servicio Rango Resolución Precisión 0,1 ˜ 99,9 % 0,1 % ± (3,0 % + 0 dígitos) Protección contra sobrecarga: 600 V CD/CA Medición de temperatura Rango Resolución Precisión -4 ˜ 1832 °F 1 °F ± (3,0 % + 3 dígitos) -20 ˜ 1000°C 1 °C ± (3,0 % + 2 dígitos) Protección contra sobrecarga: 600 V CD/CA Prueba de diodo Protección contra sobrecarga: Resolución Voltaje de circuito abierto 600 V CD/CA 1 mV Aprox. 1,5 V Prueba de continuidad Protección contra sobrecarga: Resolución Voltaje de circuito abierto 600 V CD/CA 100 mΩ Aprox. 0,45 V GARANTÍA www.kleintools.com/warranty LIMPIEZA Apague el instrumento y desconecte los cables de prueba. Limpie el instrumento con un paño húmedo. No utilice solventes ni limpiadores abrasivos. ALMACENAMIENTO Retire las baterías si no va a utilizar el instrumento durante un tiempo prolongado. No lo exponga a la humedad ni a altas temperaturas. Luego de un período de almacenamiento en condiciones extremas que sobrepasen los límites mencionados en la sección Especificaciones, deje que el instrumento vuelva a las condiciones de funcionamiento normales antes de utilizarlo. ELIMINACIÓN/RECICLAJE Precaución: Este símbolo indica que el equipo y sus accesorios están sujetos a una recolección por separado y su posterior eliminación correcta. Dwg Name: CL200-139561TART Dwg No: 139561T ECO No: 15429 Pkg Dwg Ref: 1650 Rev: B Color Reference: N/A Manual de instrucciones CL200 600 A 600 V CL200 Instruction Manuals - MASTER.indd 1-4 12/16/2013 12:16:22 PM ESPAÑOL 1 B C 3 F A E D G H H A. Utilice cables con clasif cación CAT III o superior. No intente medir más de 600 V o una corriente del valor que sea en la entrada de cable. B. Mantenga las manos por debajo de la línea cuando realice mediciones de niveles altos de corriente. C. Seleccione el botón Functionality (Funcionalidad). • Alterne entre CA y CD. • Alterne entre Ω, , y . D. Retención de datos • Presione para retener la entrada de corriente en la pantalla. • Presione nuevamente para volver a la lectura activa. E. Rango automático/manual • Presione repetidas veces para desplazarse por los rangos manuales. • Mantenga presionado durante 2 segundos para volver al modo de rango automático. • AUTO se visualiza en la pantalla LCD solo durante el modo de rango automático. F. G. Reemplazo de baterías • Cuando el indicador se muestra en la pantalla LCD, se deben reemplazar las baterías. • Quite el tornillo de la parte posterior y reemplace las 3 baterías AAA. H. Retroiluminación/Luz de trabajo • Mantenga presionado el botón para activar la luz de trabajo y la retroiluminación. • Al soltar el botón, las luces se apagarán automáticamente después de 5 segundos a 15 segundos. • La luz de trabajo solo funciona durante la medición de corriente CA. • El uso de las luces descarga las baterías considerablemente. 1 5 4 INSTRUCCIONES Y FUNCIONES En la parte posterior 2 ~ A - N L H H V V Hz F F C Ω R m M n N DETALLES DE LAS CARACTERÍSTICAS CL200 Manual de instrucciones ESPECIFICACIONES GENERALES Klein Tools CL200 es un multímetro de gancho de múltiples características. Mide voltaje CA/CD, corriente CA, resistencia, capacitancia, frecuencia, ciclo de servicio y temperatura. También sirve para probar diodos y continuidad. • Altitud de funcionamiento: 2000 metros • Humedad relativa: 75 % máx. • Temperatura operativa: 32 °F ~ 104 °F (0 °C ~ 40 °C) • Temperatura de almacenamiento: 14 °F ~ 122 °F (-10 °C ~ 50 °C) • Temperatura de precisión: 64°F ~ 82°F (18°C ~ 28°C) • Coef ciente de temperatura: 0,1*(precisión especificada)/°C • Frecuencia de muestreo: 3 muestras por segundo • Dimensiones: 8" × 3" × 1" (203 mm × 76 mm × 25 mm) • Peso: 10 oz (283 g) • Calibración: Preciso durante un año • Clasif cación de seguridad: CAT III 600V • Precisión: ± (% de lectura + cantidad de dígitos menos significativos) ADVERTENCIAS Para garantizar un funcionamiento y servicio seguros del multímetro, siga estas instrucciones. El incumplimiento de estas advertencias puede dar lugar a lesiones o provocar la muerte. • Antes de cada uso, verifique el funcionamiento del multímetro midiendo un voltaje o corriente conocidos. • Nunca debe utilizar este multímetro en un circuito con voltajes que excedan la clasificación basada en categorías del multímetro. • No utilice el multímetro durante tormentas eléctricas o en clima húmedo. • No utilice el multímetro o los cables de prueba si en apariencia están dañados. • Asegúrese de que los cables del multímetro estén correctamente colocados y mantenga los dedos lejos de los contactos de la sonda de metal al realizar las mediciones. • No abra el multímetro para reemplazar las baterías mientras las sondas están conectadas. • Proceda con precaución cuando trabaje con voltajes superiores a 60 V CD o 25 V CA RMS. Esos voltajes implican un riesgo de descarga. • Para evitar lecturas falsas que puedan provocar descarga eléctrica, reemplace las baterías si aparece el indicador de batería baja. • A menos que esté midiendo voltaje o corriente, apague y bloquee la energía antes de medir resistencia o capacitancia. • Cumpla siempre con los códigos de seguridad locales y nacionales. Utilice equipo de protección individual para prevenir lesiones por descarga y arco eléctrico en aquellos lugares donde se exponen conductores activos peligrosos. SÍMBOLOS ~ Corriente alterna CA Advertencia o precaución Corriente directa CD Niveles peligrosos Voltaje o corriente CD/CA Doble aislamiento Clase II Conexión a tierra Seguro para desconectar de conductores activos Fuente de CA 1. Corriente CA: < 600 A Características: RETENCIÓN RANGO LUZ DE TRABAJO • Centre el cable en las guías para lograr una mejor precisión. • Las corrientes opuestas se anulan entre sí (utilice un divisor de línea si es necesario). 2. Voltaje CA/CD: < 600 V Características: RETENCIÓN RANGO SÍMBOLOS UTILIZADOS EN LA PANTALLA LCD ~ Medición de CA Medición de CD - Valor negativo de CD AUTO Rango automático activo Batería baja A Corriente en amperios H Retención activa Prueba de diodo V Medición de voltaje Prueba de continuidad Hz Frecuencia en Hertz % Ciclo de servicio F Capacitancia en faradios °F Temperatura en Fahrenheit Ω Resistencia en ohmios M Mega 106 m Mili 10-3 k Kilo 103 n Nano 10-9 μ Micro 10-6 • La pantalla muestra la resistencia. • Suena el zumbador si es inferior a 60 Ω. Características de continuidad: RETENCIÓN • Seleccione una fuente de voltaje CA o CD. 3. Frecuencia (Hz)/Ciclo de servicio Características: RETENCIÓN 4. Temperatura: -4 °F ~ 1832 °F (-20 °C ~ 1000 °C) Características: RETENCIÓN • Utilice el termopar incluido. AUTO A AC AUTO A AC AUTO A AC AUTO A AC TO SELECT A AC PRESS AUTO A AC AUTO A AC ˚F ˚C PRESS Duty AUTO A AC ˚F ˚C • F < 100 μF • Espere hasta 60 segundos para la medición. • Descargue el capacitor de manera segura antes de la medición. Características de capacitancia: RETENCIÓN RANGO La pantalla muestra: • Forward voltage drop if forward biased (caída de voltaje directo si hay polarización directa). • “O.L.” if reverse biased (sobrecarga si hay polarización inversa). Características del diodo: RETENCIÓN • Ω < 40 MΩ • No mida resistencia en un circuito activo. Características de resistencia: RETENCIÓN RANGO 5. Resistencia/Capacitancia/Diodo/Continuidad Apagado automático • El dispositivo se apagará automáticamente después de 30 minutos de no utilizarlo. • Gire el dial o presione un botón para encenderlo. • Presione el botón RETENCIÓN durante el encendido para desactivar la característica Apagado automático. PRESIONAR CA CD PRESIONAR Hz Servicio PRESIONAR PARA SELECCIONAR Resistencia Diodo Capacitancia Continuidad Dwg Name: CL200-139561TART Dwg No: 139561T ECO No: 15429 Pkg Dwg Ref: 1650 Rev: B Color Reference: N/A CL200 Instruction Manuals - MASTER.indd 5-8 12/16/2013 12:16:24 PM

CL200: Related Instructions

Manuals from Other Manufacturers