Leviton ODC10-MDW Manuals

1 pdf manual(s) Leviton ODC10-MDW for free download (Document Types: Installation instructions)

Leviton ODC10-MDW Installation instructions Thumbnail

Leviton ODC10-MDW Installation instructions [PDF] (2 pages)

  • Identifier: id-853371
  • Brand: Leviton
  • Device: Leviton ODC10-MDW Kitchen Appliances
  • Type: Installation instructions, PDF
  • Key Aspects: System Connectivity and Wiring Basics, Component Overview and Descriptions, User Training Recommendations
  • UPD Date: 11.06.2026
  • Source File: 891205.pdf
  • Pages: 2
  • Description: Official user handbook for the Leviton ODC10-MDW.
Pages Preview:
  • Leviton ODC10-MDW Installation instructions preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
NOTE: Use check boxes when Steps are completed. TOOLS NEEDED TO INSTALL YOUR SENSOR DESCRIPTION Slotted/Phillips Screwdriver Small Slotted Screwdriver Cutters Wire stripper PARTS INCLUDED LIST INSTALLING YOUR OCCUPANCY SENSOR Sensor (1) 4" x 4" Mounting Plate (1) #6-32 x 1-1/2" Screw (2) Mid-Range Lens (1) Emergency Label (1) Angled Light Pipe (1) 360˚ Perforated Mask (1) Low Voltage Connector (1) Half Mask (1) Tubing Barrier (1) Wiring Sensor Connect wires per WIRING DIAGRAM as follows: 1. Insert wires into proper terminals. Use a screwdriver to turn terminal screws clockwise and secure wires. a) Line wire to Line terminal. b) Neutral wire to Neutral terminal. c) Load wire to Load terminal. d) Manual Switch and Emergency Interface to their respective marked terminals. NOTE: When wiring Manual Switch and Emergency Interface Class 2, use the provided tubing for insulation inside the junction box. NOTE: Wires need to be inserted from the top through the wire holes provided on the sensor and clamped down using the washer to the terminals. Mount Sensor in Electrical Box To mount inside 4" octagon 2.125" deep ceiling electrical box, refer to Figure 1. • Dress line voltage wires to provide enough clearance in electrical box when device is installed. • Partially thread two #8-32 screws (not included) into the mounting holes of the electrical box. • Pull out the two coasters that align with the two screws. • Align sensor so that it fits between the mounting holes of the electrical box and insert over mounting screws. • Push in the two coasters that align with the two screws. • Tighten mounting screws firmly. MOUNT SENSOR IN ELECTRICAL BOX WITH MUD RING To mount inside 4" square 1.5" deep ceiling electrical box with mud ring, refer to Figure 2 below. • Ensure that conduit/cable entry clamp is located in corner of electrical box. • Dress line voltage wires to provide enough clearance in electrical box when device is installed. • Install a two-gang mud ring (not included) on electrical box. • Partially thread the two #6-32 screws provided into the mounting holes of the electrical box. • Pull out the two coasters that align with the two screws. • Align sensor so that it fits between the mounting holes of the electrical box and insert over mounting screws. • Push in the two coasters that align with the two screws. • Tighten mounting screws firmly. PK-93308-10-00-2B • Make sure that the ends of the wires from the electrical box are straight (cut if necessary). • Remove insulation from each wire in electrical box as shown. • Wire per Specifications: Line, Neutral, Load Wires (Copper) Wire range: #12-18 AWG, 3.3 - 0.75 mm square - Torque rating: 20 lb-in, 23 kgf-cm. Control Wires (Manual Switch and Emergency Interface) Wire range: #16-26 AWG, 4.0 - 0.12 mm square - Torque rating: 2.5 lb-in, 2.88 kgf-cm. Preparing and connecting wires: Cut (if necessary) 3/4" (1.9 cm) Strip Gage (measure bare wire here) Step 3 ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF Step 1 WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and TEST that power is off before wiring! WARNINGS AND CAUTIONS: • TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING! • To be installed and/or used in accordance with appropriate electrical codes and regulations. • If you are unsure about any part of these instructions, consult an electrician. • Sensors must be mounted on a vibration free surface. • Do not terminate using data type wire, such as Cat 5/5E. • Do not mount sensors closer than 10 feet to each other. • All sensors must be mounted at least 6 feet away from air vents, air handlers, and reflective surfaces (windows/mirrors). • Do not touch the surface of the lens. Clean outer surface with a damp cloth only. WARNINGS AND CAUTIONS: For Occupancy Sensors installed to control Emergency Lighting Equipment: If this equipment is being used for Emergency Lighting and Power Equipment, please adhere to the following information. This equipment is rated for only 25C if used on Emergency Lighting Equipment. Apply the "Emergency Circuits" label (provided) to the front cover. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: a) READ AND FOLLOW ALL SAFETY INSTRUCTIONS. b) DO NOT use outdoors. c) DO NOT mount near gas or electric heaters. d) Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. e) The use of accessory equipment not recommended by manufacturer may cause an unsafe condition. f) DO NOT use this equipment for other than the intended use. SAVE THESE INSTRUCTIONS All servicing shall be performed by qualified service personnel. If any Emergency Circuits are fed or controlled from this panel, it must be located electrically where fed from a UPS, generator, or other guaranteed source of power during emergencies and power outage situations. Identifying your wiring: Step 2 4 5 6 7 3 1 2 LOAD OUT L1 LINE L1 NEUT. N NC NC 12VDC CLASS 1 OR 2 (SELV) MAN SW NC NC MS + – + – MS EM EM EMER. INPUT Installing your Sensor: Step 4 12VDC CLASS 1 OR 2 (SELV) MAN SW NC NC MS + – + – MS EM EM EMER. INPUT Emergency Interface Neutral 120-277VAC 50/60Hz } Line Manual Switch Load LOAD OUT L1 LINE L1 NEUT. N NC NC PHOTOCELL AND DAYLIGHTING OPERATIONS Daylight harvesting is used for additional energy savings. The photocell holds the lights OFF when sufficient ambient light is present. Typical light levels are measured in foot-candles or lux, and average office areas are designed to utilize 50-60 foot candles/500-600 lux. The "Daylight Design Level" (DDL), when set per the calibration section, will be the set point which engages the hold-off feature for daylight harvesting. 120V 60Hz 277V 60Hz 800W/VA, Tungsten, Ballast 8A, Electronic Ballast 1/4 hp 1200VA, Ballast 5A, Electronic Ballast 1/3 hp Rating: 6A-6AX 250V Operating Temperature: 32˚ to 104˚F (0˚ to 40˚C) 720-1440 W/VA 120-240 50Hz M CALIBRATION After the sensor is installed, the photocell must be configured correctly to maintain the desired light level and gain additional energy savings. To achieve this, the installer first needs to understand Closed and Open Loop Daylighting, then decide which application best fits the customer's needs before configuring and calibrating the device. • Open Loop: When a photocell (light pipe) is focused on an area which is primarily illuminated by natural light from windows or skylights, along with a minimal amount of artificial light from the lights it is controlling. NOTE: Use the angled light pipe for Open Loop applications. Open Loop MUST be used only with Manual Calibration mode. The sensor will not enter Automatic Calibration mode if Open Loop Daylight Harvesting is selected. • Closed Loop: When a photocell (light pipe) is focused on an area which is primarily illuminated by the lights it is controlling. NOTE: Use the flat light pipe for Closed Loop applications. Figure 2 1. Line (Hot) - L1 2. Load - L1 3. Neutral - N 4. Manual Switch + 5. Manual Switch – 6. Emergency Interface + 7. Emergency Interface – OCCUPANCY SENSOR OPERATION Motion detection by the multi-technology sensor will turn the lights ON as well as keep them ON. When motion is not detected, the lights will turn OFF after the delayed-off time. • Delayed-Off time: The sensor is designed to turn the lights OFF if no motion is detected after a specified time. This length of time is called the delayed-off time and is set using the timer (Black) knob on the sensor. • Walk-through Mode: The walk-through feature is useful when a room is momentarily occupied. The walk-through feature works as follows: When a person enters the room, the lights will turn ON. If the person leaves the room before the default walk-through timeout of 2.5 minutes, the sensor will turn the lights OFF 2.5 minutes later. If the person stays in the room for longer than 2.5 minutes, the sensor will proceed with the standard operation. • Reset Device State: To reset Auto adapting and photocell settings to factory default. • Manual ON/OFF Switch: Use to override occupancy and manually turn the lights ON or OFF by pressing the low voltage momentary/toggle switch. Pressing manual switch will reset the time delayed OFF timer and lights will turn OFF after the delayed-off timer expires. • Emergency Interface: This input is intended for use with BMS (Building Management System) or any contact closure to force the lights ON in case of emergency. Lights will stay ON until emergency signal is cleared. Modes of Operation: Selectable using Bank C Dip Switches The Auto ON/Auto OFF Occupancy Sensor can be turned ON and OFF automatically based on occupancy, a timer, panel or BMS input, and manually from an optional low voltage switch. • MANUAL ON (Mode 1) Occupants must press the low voltage switch to turn the load ON. When the occupancy sensor is the only input keeping the load ON, the load turns OFF when the sensor time delay expires. If the sensor input re-triggers within 30 seconds after the load turns OFF, the load turns ON again. After the 30 seconds expire with no sensor input, press the momentary switch to turn the load ON. • AUTO ON (Mode 2) The load can be turned ON based on occupancy detection or by using the optional switch input. When the load is turned OFF using the switch, the Occupancy Sensor does not turn it ON automatically until after the sensor time delay expires (e.g., presentation mode). When the sensor's time delay expires, the sensor reverts to Auto ON mode and turns the load ON with the next input from the sensor or switch input. AUTO ADAPTING The Sensor continually analyzes the parameters of the motion detection signal and adjusts its internal operation to maximize detection of motion while minimizing the effects of noise (electrical noise, air currents, temperature changes, etc…). Operation When the sensor is first installed, the delayed-off time for the occupied mode is based on the Time adjustment settings. While the sensor is in use, the delayed-off time will change, based on how the sensor adapts to the room conditions. The adapted settings can be reset by moving B3 from OFF to ON to OFF position. Occupancy Pattern Learning For Delayed-Off Time The sensor will automatically change the Delayed-Off Time in response to detected occupancy patterns. The Delayed-Off Time will be decreased if large periods of vacancy are detected, which will result in energy savings. The Delayed-Off Time will be increased if false-off conditions are detected. Occupancy Pattern Learning for Multi-Technology The sensor learns the occupancy patterns of a space during the course of a day, for a seven day period. The sensor will adjust the sensitivity to make it less likely to turn ON during a historically vacant time period. Test Mode: To set the delayed-off time to 4 seconds for performing a walk test. While the sensor is in test mode, the LED’s will flash YELLOW once every second. 1. ENSURE POWER IS ON. 2. Remove front cover. 3. Locate dip switch 3 in Bank B (B3) (refer to Table 2). B3 will be in the OFF position from the factory. 4. To enter Test mode, move switch to ON. The Test mode has now been entered with a 4 second time-out. NOTE: If B3 is already in the ON position, then Test mode can be entered by just moving it to the OFF and then ON position. NOTES: 1. The timer will remain in the 4 second Test mode for 15 minutes, then automatically exit Test mode and reset to the delayed-off time setting as defined by the Black timer knob. 2. To manually take the timer out of the 4 second Test mode, simply move switch B3 back to OFF. 3. Entering Test mode will reset all adapted settings. Figure 1 light pipe Coaster light pipe 4"x 4" Cosmetic adapter Coaster Multi-Technology Ceiling Mounted Line Voltage Occupancy Sensor California Title 20 Compliant Cat. No. ODCØ5-MDW, ODC1Ø-MDW, ODC2Ø-MDW No Minimum Load Required Compatible with electronic and magnetic ballasts, electronic and magnetic low-voltage transformers, incandescent lamps, and fans INSTALLATION INSTRUCTIONS Mount in corner/over doorway Mount in center of room, 8-12 ft height Mount in center of room, 8-12 ft height Suggested Mounting Location 500 sq. ft. 1000 sq. ft. 2000 sq. ft. Coverage ODC05-MDW ODC10-MDW ODC20-MDW Cat. No. 1-Way Multi-Tech 2-Way Multi-Tech 2-Way Multi-Tech Description 120-277,50/60Hz 120-277,50/60Hz 120-277,50/60Hz Voltage Range 60-30ma 60-30ma 60-30ma Current Consumption CATALOG ITEMS The Occupancy Sensor is a LINE-voltage multi-technology sensor to automatically control lighting. The sensor turns the lights ON and keeps them ON whenever occupancy is detected and will turn them OFF after the "delayed-off time" has expired. The sensor continually analyzes and adjusts to changing conditions. The sensor uses the latest microprocessor-based technology which permits it to continually adjust and optimize its performance. The combination of ultrasonic (doppler shift) motion detection which gives maximum sensitivity and infrared motion detection which gives higher false triggering immunity yields a sensor with excellent performance.

Similar Manuals in the Kitchen Appliances Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Hamilton Beach Big Mouth Plus 2 Speed Juice Extractor

#X4971B: Big Mouth Plus 2 Speed Juice Extractor Kitchen Appliances Operation manual

90 1281 308 31-03-2026 view all manuals
Linea 2000 Domo DO8712W

Linea 2000 Domo DO8712W User Manual (Instruction booklet), @C2FL1V

40 458 83 25-03-2026 view all manuals
Omron ZW-C1*T

Kitchen Appliances #LPD2L1

322 582 134 08-07-2026 view all manuals
Bosch 940ES

Water Heater #JNL6GB

64 1349 216 29-08-2026 view all manuals
Jenn-Air JGD8348CDP

Jenn-Air Cooktop Installation instructions manual (File: PDF, 03-06-2026)

36 1423 285 03-06-2026 view all manuals
Taurus INOX TORRAT

Manual: Taurus INOX TORRAT (3EFRG1, Upd.11-08-2026)

20 1120 202 11-08-2026 view all manuals