Moldex Bitrex Manuals
2 pdf manual(s) Moldex Bitrex for free download (Document Types: Instructions, Test instructions)
Moldex Bitrex Instructions [PDF] (2 pages)
- Identifier: id-2325134
- Brand: Moldex
- Device: Moldex Bitrex Test Equipment
- Type: Instructions, PDF
- Key Aspects: Safety Recommendations and Warnings, Critical Operational Precautions, System Connectivity and Wiring Basics
- UPD Date: 16.07.2026
- Source File: 1962472.pdf
- Pages: 2
- Description: Maintenance and service manual for the Moldex Bitrex.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
A. EQUIPMENT REQUIRED 1. Moldex Bitrex Qualitative Fit Test Kit (#0102) 2. Moldex Bitrex Quantative Test Hood (#0201) 3. Nebulizer #1 (BITREX Sensitivity Solution) (#0301) 4. Nebulizer #2 (BITREX Fit Test Solution) (#0302) 5. Two sets Replacement Nebulizer Inserts 6. BITREX Fit Test Solution Applicator Tube (#0504) 7. BITREX Sensitivity Solution Applicator Tube (#0503) 8. Appropriate Moldex Respirators* *Use with any Moldex N, R or P class disposable respirator. This fit test kit may also be used with any Moldex half mask or full face respirator by using any N, R or P class filter. **This fit test kit may also be used with any Moldex half mask or full face respirator by using any N, R or P class filter as a stand alone or in combination with any chemical cartridge. The maximum fit-factor allowed for qualatatively fit testing a Full Face is 10. B. NEBULIZER PRE-INSPECTION AND PREPARATION 1. Remove the top half of the nebulizer by unthreading it from the bottom half. (Repeat for each nebulizer) 2. Using your index finger lightly push down on the Atomizer to ensure that it is pushed down all the way onto the bottom half of the nebulizer. (See Diagram 1). (Repeat for each nebulizer) 3. Inspect and ensure that the black O-ring is properly seated. (Repeat for each nebulizer) 4. Replace the top half of nebulizer and remove plug from nebulizer exhaust port. (Repeat for each nebulizer) C. BITREX APPLICATOR INSTRUCTIONS 5. WARNING: When crushing the applicator tubes to release the product, it is important to wear protective gloves. It is also important to “pinch” the applicator tube to break the glass ampoule when releasing the liquid into the tube. DO NOT BEND THE TUBE! (See Diagrams 2 and 3) 6. PREPARATION: Remove Sensitivity Test Applicator and/or the Fit Test Applicator from its storage box. With the fill tip pointed upward, pinch along the full length of the applicator tube using your thumb and forefinger until glass ampoule inside of the applicator tube is thoroughly crushed. (Warning: It is important to keep the applicator tip pointed upward when pinching the tube. This is to prevent the solution from squirting out during the pinching process.) (See Diagram 4) 7. Remove the End Cap from the nebulizer. Insert the applicator tip into the opening of the nebulizer. Squeeze along the applicator tube to transfer the solution from the applicator down into the nebulizer until the applicator is completely drained of the solution. (Warning: Do not attempt to remove the tip of the applicator. It contains a porous filter which is designed to allow the solution to pass through it while filtering out the glass ampoule particles. It is also not necessary to puncture a hole or cut the tip of the applicator. The applicator tip already has the proper hole size in it to allow the solution to squirt into the nebulizer.) (See Diagrams 5 and 6) (Note: It is recommended that the protective end cap be replaced back on the nebulizer until the test is ready to be performed.) Use the foam cushion insert in the fit test kit to hold the nebulizer(s) upright. BITREX QUALITATIVE FIT TEST INSTRUCTIONS 8. Once the applicator solution has been drained into the nebulizer, it can safely be disposed. 9. Ensure that each nebulizer is able to produce solution mist via the exhaust port by removing plug from Breather Vent and squeeze bulb 4-5 times. If solution mist is not visible or seems very weak, carefully (so not to spill the solution) remove the top half of the nebulizer by unthreading it from the bottom half and repeat #B-2. (See Diagram 1). (Repeat for each nebulizer) D. TASTE SENSITIVITY SCREENING Purpose: This test is done to ensure that the person being fit tested can detect the taste of BITREX at sufficiently low levels to make the fit test valid. 1. Ensure that the test subject does not eat, drink, smoke or chew gum for 15 minutes before the test. 2. Explain the screening and fit testing procedures to the subject. 3. Instruct subject to put on the hood without a respirator. 4. Position the hood forward so there is about six inches between the subject’s face and the window. This is especially important for the fit test. It allows free movement of the head when the subject is wearing a respirator and helps ensure even dispersion of the aerosol around the face seal area. 5. Instruct the test subject to breathe with their mouth slightly open and tongue extended. 6. Using the nebulizer labeled BITREX Sensitivity Solution, inject the aerosol into the hood through the hole in front of the enclosure. Inject ten (10) squeezes of the bulb, fully collapsing and fully expanding the bulb on each squeeze. 7. Ask the subject if he can detect the bitter taste of BITREX. 8. If the subject does not detect bitter taste, inject an additional ten squeezes into the hood. 9. If the subject still does not detect bitter taste, inject an additional ten squeezes, for a total of 30 squeezes. 10. If 30 squeezes were inadequate to elicit a response from the subject, this subject cannot be fit tested with the BITREX test. Another fit test method must be used. 11. If the subject could detect bitter taste, the number of squeezes required to produce a taste response should be noted, i.e., 10, 20 or 30 squeezes, even if subject tasted the BITREX on a number of squeezes other than multiples of ten. 12. Remove the hood. Wait a few minutes, to give the subject time to clear the taste from his mouth, before proceeding to the fit test. A drink of water during this time will aid in removing the bitter taste. Use a paper towel to wipe the subject’s mouth of any residue (also wipe mustaches). ® 1 2 3 4 5 6 Correct Incorrect
Moldex Bitrex Test instructions [PDF] (2 pages)
- Identifier: id-2128503
- Brand: Moldex
- Device: Moldex Bitrex Test Equipment
- Type: Test instructions, PDF
- Key Aspects: Step-by-Step Assembly Procedures, Control Panel and Interface Navigation, Package Contents and Accessories List
- UPD Date: 20.08.2026
- Source File: 2159134.pdf
- Pages: 2
- Description: Detailed product documentation for the Moldex Bitrex.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
A. EQUIPMENT REQUIRED 1. Hood 2. Nebulizer #1 (BITREX® Sensitivity Solution) 3. Nebulizer #2 (BITREX® Fit Test Solution) 4. Two sets Replacement Nebulizer Inserts 5. BITREX Fit Test Solution Applicator Tube (#0504) 6. BITREX Sensitivity Solution Applicator Tube (#0503) 7. Appropriate Moldex® Respirators* *Use with any Moldex N, R or P class disposable respirator. This fit test kit may also be used with any Moldex half mask respirator by using any N, R or P class filter. B. NEBULIZER PRE-INSPECTION AND PREPARATION 1. Remove the top half of the nebulizer by unthreading it from the bottom half. (Repeat for each nebulizer) 2. Using your index finger lightly push down on the Atomizer to ensure that it is pushed down all the way onto the bottom half of the nebulizer. *See Figure 1 (Repeat for each nebulizer). 3. Inspect and ensure that the black O-ring is properly seated. (Repeat for each nebulizer) 4. Replace the top half of nebulizer and remove plug from nebulizer exhaust port. (Repeat for each nebulizer) 5. Use rubber or other protective gloves prior to next step. 6. Get one Sensitivity Solution applicator tube from box of (6) part #0503 and hold upright and squeeze several times until glass ampoule is crushed. Insert applicator tip into the Exhaust Port of the nebulizer labeled “Sensitivity Solution” and squeeze the applicator until drained. Use the foam cushion insert in the Fit Test kit to hold the nebulizer(s) upright. See Figure 2 7. Get one Fit Test Solution applicator tube from box of (6) part #0504 and hold upright and squeeze several times until glass ampoule is crushed. Insert applicator tip into the Exhaust Port of the nebulizer labeled “Test Solution” and squeeze the applicator until drained. 8. Ensure that each nebulizer is able to produce solution mist via the exhaust port by removing plug from Breather Vent and squeeze bulb 4 – 5 times. If solution mist is not visible or seems very weak, carefully (so not to spill the solution) remove the top half of the nebulizer by unthreading it from the bottom half and repeat #2 above. (Repeat for each nebulizer) C. TASTE SENSITIVITY SCREENING Purpose: This test is done to ensure that the person being fit tested can detect the taste of BITREX at sufficiently low levels to make the fit test valid. 1. Ensure that the test subject does not eat, drink, smoke or chew gum for 15 minutes before the test. 2. Explain the screening and fit testing procedures to the subject. 3. Instruct subject to put on the hood without a respirator. 4. Position the hood forward so there is about six inches between the subject’s face and the window. This is especially important for the fit test. It allows free movement of the head when the subject is wearing a respirator and helps ensure even dispersion of the aerosol around the face seal area. 5. Instruct the test subject to breathe with their mouth slightly open and tongue extended. 6. Using the nebulizer labeled BITREX Sensitivity Solution, inject the aerosol into the hood through the hole in front of the enclosure. Inject ten (10) squeezes of the bulb, fully collapsing and fully expanding the bulb on each squeeze. 7. Ask the subject if he can detect the bitter taste of BITREX. 8. If the subject does not detect bitter taste, inject an additional ten squeezes into the hood. 9. If the subject still does not detect bitter taste, inject an additional ten squeezes, for a total of 30 squeezes. 10. If 30 squeezes were inadequate to elicit a response from the subject, this subject cannot be fit tested with the BITREX test. Another fit test method must be used. 11. If the subject could detect bitter taste, the number of squeezes required to produce a taste response should be noted, i.e., 10, 20 or 30 squeezes, even if subject tasted the BITREX on a number of squeezes other than multiples of ten. 12. Remove the hood. Wait a few minutes, to give the subject time to clear the taste from his mouth, before proceeding to the fit test. A drink of water during this time will aid in removing the bitter taste. Use a paper towel to wipe the subject’s mouth of any residue (also wipe mustaches). Figure 1 Figure 2 Ideas that wear well. ®
Similar Manuals in the Test Equipment Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
HT MPP300 |
MPP300 (Test Equipment ePDF User Guide, #JVX5D1) |
28 | 900 | 135 | 11-07-2026 | view all manuals | |
Keithley 2520 |
Keithley Test Equipment Operation & user’s manual (File: PDF, 30-03-2026) |
329 | 176 | 44 | 30-03-2026 | view all manuals | |
KEY HT-300 |
PDF User Manual (@868752), KEY HT-300 Test Equipment (31-03-2026) |
16 | 1063 | 192 | 31-03-2026 | view all manuals | |
Circassia NIOX VERO |
NIOX VERO Operation & user’s manual - 3552DP |
55 | 1420 | 355 | 20-06-2026 | view all manuals | |
IDEAL LinkMaster PRO XL |
LinkMaster PRO XL (Test Equipment ePDF Manual, #OXT2L5) |
7 | 1284 | 193 | 11-08-2026 | view all manuals | |
Desco 19276 |
PDF User Guide (@79G2W4), Desco 19276 Test Equipment (19-07-2026) |
7 | 134 | 30 | 19-07-2026 | view all manuals |