Omron 3G3AX-MX2-EIP-A Manuals

1 pdf manual(s) Omron 3G3AX-MX2-EIP-A for free download (Document Types: Instruction sheet)

Omron 3G3AX-MX2-EIP-A Instruction sheet Thumbnail

Omron 3G3AX-MX2-EIP-A Instruction sheet [PDF] (3 pages)

  • Identifier: id-853121
  • Brand: Omron
  • Device: Omron 3G3AX-MX2-EIP-A Control Unit
  • Type: Instruction sheet, PDF
  • Key Aspects: Warranty and Service Information, Operational Mode Explanations, Safety Recommendations and Warnings
  • UPD Date: 29.04.2026
  • Source File: 891455.pdf
  • Pages: 3
  • Description: Official installation manual for the Omron 3G3AX-MX2-EIP-A.
Pages Preview:
  • Omron 3G3AX-MX2-EIP-A Instruction sheet preview - page 2
  • Omron 3G3AX-MX2-EIP-A Instruction sheet preview - page 3
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Model 3G3AX-MX2-EIP-A INSTRUCTION SHEET Thank you for purchasing an OMRON product. Read this thoroughly and familiarize yourself with the functions and characteristics of the product before using it. Keep this instruction sheet for future reference. OMRON Corporation © 2011 OMRON Electronics LLC All rights reserved I37I-E-01 ■ General Precautions The user must operate the product according to the performance specifications described in this instruction sheet and in the operation manual of the inverter. Before using the product under conditions which are not described in the inverter manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems, machines, and equipment that may have a serious influence on lives and property if used improperly, consult your OMRON representative. Make sure that the ratings and performance characteristics of the product are sufficient for the systems, machines, and equipment, and be sure to provide the systems, machines, and equipment with double safety mechanisms. • The MX2-A□ inverter with a mounted 3G3AX-MX2-EIP-A option board is a general purpose product combination. It is a system component and is used in conjunction with other items of industrial equipment such as PLCs. • A detailed system analysis and job safety analysis should be performed by the system designer or system integrator before including the inverter option board combination in any new or existing system. Consult your OMRON representative for application specific system integration information if required. • The product will be used to control an adjustable speed drive connected to high voltage sources and rotating machinery that is inherently dangerous if not operated safely. Interlock all energy sources, hazardous locations, and guards in order to restrict the exposure of personnel to hazards. The adjustable speed drive may start the motor without warning. Signs on the equipment installation must be posted to this effect. A familiarity with auto-restart settings is a requirement when controlling adjustable speed drives. Failure of external or ancillary components may cause intermittent system operation, i.e., the system may start the motor without warning or may not stop on command. Improperly designed or improperly installed system interlocks and permissives may render a motor unable to start or stop on command. • This Instruction Sheet does not contain illustrations of the product with protective covers removed from the MX2-A□ inverter. Make sure that these protective covers are on the inverter before use. ■ Safety Precautions Definition of Precautionary Information WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Additionally, there may be severe property damage. Caution Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury, or property damage. ■ Warnings and Cautions WARNING Do not attempt to take an option board apart or touch any internal parts while the power is being supplied. Doing so may result in electric shock. WARNING Do not touch the conductive parts such as the internal PCB or connector while power is being supplied. Doing so may result in electrical shock. WARNING Do not attempt to disassemble, repair, or modify an option board. Any attempt to do so may result in malfunction, fire, or electric shock. WARNING Wiring, maintenance or inspection must be performed by authorized personnel. Not doing so may result in electrical shock or fire. WARNING Turn OFF the power supply before performing wiring, maintenance or inspection. Wait for the time specified on the Inverter front cover for the capacitors to discharge. Not doing so may result in electrical shock. WARNING Provide safety measures in external circuits, i.e. not in the option board. This ensures safety in the system if an abnormality occurs due to malfunction of the option board or another external factor affecting the option board operation. Not doing so may result in serious accidents. WARNING Refer to the section “MX2 Inverter Safety (ISO 13849-1)” for details if the safety measures mentioned in the previous warning are to be ensured using the Gate Suppress function of the MX2-A□ inverter. WARNING Emergency stop circuits, interlock circuits, limit circuits, and similar safety measures must be provided in external control circuits. WARNING Fail-safe measures must be taken by the customer to ensure safety in the event of incorrect, missing, or abnormal signals caused by broken signal lines, momentary power interruptions, or other causes. Not doing so may result in serious accidents. Caution Do not touch the inverter during power-on, and immediately after power-off. Hot surface may cause injury. ■ Operating Environment Precautions Caution Do not operate the MX2-A□ inverter with a mounted 3G3AX-MX2-EIP-A option board in the following locations (doing so may result in malfunction, electric shock or burning): • Locations subject to direct sunlight • Locations subject to temperatures or humidity outside the range specified in the specifications • Locations subject to condensation as the result of severe changes in temperature • Locations subject to corrosive or flammable gases • Locations subject to dust (especially iron dust) or salts • Locations subject to exposure to water, oil, or chemicals • Locations subject to shock or vibration Caution Take appropriate and sufficient countermeasures when installing systems in the following locations (doing so may result in malfunction): • Locations subject to static electricity or other forms of noise • Locations subject to strong electromagnetic fields • Locations subject to possible exposure to radioactivity • Locations close to power supplies Caution The operating environment of the MX2-A□ inverter with a mounted 3G3AX-MX2-EIP-A option board can have a large effect on the longevity and reliability of the system. Improper operating environments can lead to malfunction, failure, and other unforeseeable problems with the system. Make sure that the operating environment is within the specified conditions at installation and remains within the specified conditions during the life of the system. ■ Application Precautions WARNING Failure to abide by the following precautions could lead to serious or possibly fatal injury. Always read these precautions. • Always connect the grounding cable to one of the ground terminals of the MX2-A□ inverter. • Check any user program in the system that acts as a EtherNet/IP master before actually running it. Not checking the program may result in unexpected operation. Caution Failure to abide by the following precautions could lead to faulty operation of the option board or the inverter, or could damage either of the two. Always read these precautions. • Install external breakers and take other safety measures against short-circuits in external wiring. Not observing this may result in burning. • Be sure that all the cable connector screws are tightened to the torque specified in the relevant manuals. Incorrect tightening torque may result in malfunction. • Do not allow metal clippings to enter either option board or inverter when wiring or installing the unit. • Follow the network configuration and wiring instructions provided in the “EtherNet/IP Operation Manual” (Cat. No. W465). o Wire the EtherNet/IP cables correctly. Incorrect wiring may result in burning. o Wire the EtherNet/IP connectors correctly. Incorrect wiring may result in burning. o Apply termination at both ends of a EtherNet/IP cable segment. Do not apply termination anywhere else. • Be sure that the option board is mounted correctly. Improper mounting may result in malfunction. • Disconnect the grounding cable when performing withstand voltage tests. Not disconnecting the grounding cable may result in burning. • Check the inverter settings for proper inverter behaviour before actually operating the inverter remotely via the EtherNet/IP network. • Check the network related inverter settings regarding EtherNet/IP node address and EtherNet/IP remote I/O allocation. Not doing so may result in unexpected operation. • Check the inverter’s EzSQ program and its interaction with the EtherNet/IP master before actually running it on the inverter. Not checking the program may result in unexpected operation. • When replacing an inverter be sure that all inverter settings of the inverter being replaced are restored to the replacement. • Parameters for the module are stored in the module and must be restored if the module is replaced. The setup parameters for the 3G3AX-MX2-EIP-A are not stored in the drive. Always check the node address and other network related inverter settings after restore. • Confirm that no adverse effect will occur at the moment the EtherNet/IP master stops communicating with the inverter or at the moment the EtherNet/IP master has not yet started communicating to the inverter. • Confirm that no adverse effect will occur in the inverter before force- setting/force-resetting any bit in the system that acts as a EtherNet/IP master. ■ Handling, Storage and Disposal • Before touching the option board or inverter, be sure to first touch a grounded metallic object in order to discharge any static built-up. Not doing so may result in malfunction or damage. • When transporting or storing the option board, cover the PCBs with electrically conductive materials to prevent electronic components from being damaged by static electricity. Also keep the product within the specified storage temperature range. • Never dispose electrical components by incineration. Contact your state environmental agency for details on disposal of electrical components and packaging in your area. ■ Compliance with EC Directives • This product complies with EC Directives when mounted on an MX2-A□ inverter and having connected the grounding cable. For grounding, cable selection, and any other conditions for EMC compliance, refer to the MX2 User’s Manual for installation. ■ References Please be sure to read the related user manuals to use the 3G3AX-MX2-EIP-A option board safely and properly. Be sure you are using the most current version of the manual. Name Cat No. 3G3AX-MX2-EIP-A Option Board User’s Manual I36I MX2 User’s Manual I570 EtherNet/IP Operation Manual W465 SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. See also product catalogs for Warranty and Limitations of Liability.

Similar Manuals in the Control Unit Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Quectel MC60-TE-A

MC60-TE-A (Adapter ePDF User Manual, #TWB4Y2)

24 81 15 16-07-2026 view all manuals
Samson 3323

#4CDUL1: 3323 Control Unit Mounting and operating instructions

24 1376 276 04-08-2026 view all manuals
TimeTec BLE-2

BLE-2 (Relays ePDF Guide, #9T72LQ)

6 634 146 02-08-2026 view all manuals
Burkert 2103

Burkert Control Unit Operating instructions manual (File: PDF, 11-07-2026)

50 351 88 11-07-2026 view all manuals
Jflow controls DM4800 SERIES

DM4800 SERIES Installation and maintenance manual - O2ZV67

5 786 158 24-04-2026 view all manuals
STIEBEL ELTRON KV 30

User Guide: STIEBEL ELTRON KV 30 (24FW87, Upd.28-04-2026)

48 238 53 28-04-2026 view all manuals