PCE Instruments PCE-228 Manuals

4 pdf manual(s) PCE Instruments PCE-228 for free download (Document Types: Manual , Operation & user’s manual)

PCE Instruments PCE-228 Manual  Main Page Preview

Manual  [PDF] (17 pages)

  • Updated: 11.08.2026

Document Preview & Text Transcription

Manual Water Analysis Meter PCE-228 Version 1.0 Date of creation: 22.01.2016 Date of last change: 22.01.2016 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 [email protected] www.pce-instruments.com/english www.pce-instruments.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park Ensign way Hampshire / Southampton United Kingdom, SO31 4RF From outside UK: +44 Tel: (0) 2380 98703 0 Fax: (0) 2380 98703 9 [email protected] Manual 2 Contents 1 Introduction ....................................................................................................................... 3 2 Safety notes ....................................................................................................................... 3 3 Specifications .................................................................................................................... 4 3.1 General ...................................................................................................................................................... 4 3.2 Electrical (23 ± 5 °C) .................................................................................................................................. 4 4 System description ........................................................................................................... 5 5 pH / mV measurement and calibration procedure ........................................................... 6 5.1 pH measurement (manual temperature compensation) ............................................................................. 7 5.2 pH measurement (ATC, automatic temperature) ....................................................................................... 7 5.3 mV measurement ...................................................................................................................................... 7 5.4 pH calibration ............................................................................................................................................. 7 6 Other functions .......................................................................................................... 9 6.1 Data Hold ................................................................................................................................................... 9 6.2 Data record (MAX / MIN reading) .............................................................................................................. 9 6.3 LCD backlight on/off................................................................................................................................... 9 7 Datalogger ................................................................................................................. 9 7.1 Preparation before using the datalogger function ...................................................................................... 9 7.2 Auto datalogger (set sampling time ≧ 1 second) ...................................................................................... 9 7.3 Manual datalogger (set sampling time = 0 second) ................................................................................. 10 7.4 How to check the time information ........................................................................................................... 10 7.5 How to check the sampling time information ............................................................................................ 10 7.6 SD card data structure ............................................................................................................................. 11 8 Saving data from the SD card to the computer (EXCEL software) ............................... 11 9 Advanced settings ........................................................................................................... 12 9.1 SD memory card format ........................................................................................................................... 13 9.2 Set clock time (Year/Month/Date, Hour/Minute/Second).......................................................................... 13 9.3 Set sampling time (Hour/Minute/Second) ................................................................................................ 13 9.4 Auto power off management .................................................................................................................... 13 9.5 Set beeper sound on/off........................................................................................................................... 14 9.6 Decimal point of SD card setting .............................................................................................................. 14 9.7 Select the temperature unit °C or °F ........................................................................................................ 14 9.8 Set the pH manual temperature compensation value .............................................................................. 14 9.9 ESC ......................................................................................................................................................... 14 10 Power supply from optional mains adaptor .................................................................. 15 11 Battery replacement ........................................................................................................ 15 12 System reset .................................................................................................................... 15 13 RS-232 PC serial interface .............................................................................................. 15 14 Disposal ........................................................................................................................... 17 15 Contact ............................................................................................................................. 17 15.1 PCE Instruments UK ................................................................................................................................ 17 15.2 PCE Americas ......................................................................................................................................... 17 Manual 3 1 Introduction Thank you for purchasing a PCE-228 from PCE Instruments. * pH : 0 to 14.00 pH, mV ( ORP ) : ± 1999 mV. * pH measurement can select ATC or manual Temp. adj.. * Optional ATC probe for pH measurement. * pH measurement can make the auto calibration for pH 7, pH 4 and pH 10 or other value. * Real time SD memory card Datalogger, it Built-in Clock and Calendar, sampling time set from 1 sec to 8 hour 59 min. 59 sec. * Manual datalogger is available ( set the sampling time to 0 ), during execute the manual datalogger function, it can set the different position ( location ) No. ( position 1 to position 99 ). * Innovation and easy operation, computer is not need to setup extra software, after execute datalogger, just take away the SD card from the meter and plug in the SD card into the computer, it can down load the all the measured value with the time information ( year/month/date/hour/minute/second ) to the Excel directly, then user can make the further data or graphic analysis by themselves. * SD card capacity : 1 GB to 16 GB. * LCD with green light backlight, easy reading. * Can default auto power off or manual power off. * Data hold, record max. and min. reading. * Microcomputer circuit, high accuracy. * Power by UM3/AA ( 1.5 V ) x 6 batteries or DC 9V adapter. * RS232/USB PC COMPUTER interface. * Wide applications: water conditioning, aquariums, beverage, fish hatcheries, food processing, photography,laboratory, paper industry, plating industry, quality control, school & college, water conditioning. 2 Safety notes Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. There is no warranty of damages or injuries caused by non-observance of the manual. - The device may only be used in the approved temperature range. - The case should only be opened by qualified personnel of PCE Instruments. - The instrument should never be placed with the user interface facing an object (e.g. keyboard side on a table). - You must not make any technical changes to the device. - The appliance should only be cleaned with a damp cloth / use only pH-neutral cleaner. This user's handbook is published by PCE Instruments without any guarantee. We expressly point to our general guarantee terms which can be found in our general terms of business. If you have any questions please contact PCE Instruments.
PCE Instruments PCE-228 Manual  Main Page Preview

Manual  [PDF] (17 pages)

  • Updated: 13.07.2026

Document Preview & Text Transcription

Manual Redox Meter PCE-228 Version 1.0 Date of creation: 22.01.2016 Date of last change: 22.01.2016 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 [email protected] www.pce-instruments.com/english www.pce-instruments.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park Ensign way Hampshire / Southampton United Kingdom, SO31 4RF From outside UK: +44 Tel: (0) 2380 98703 0 Fax: (0) 2380 98703 9 [email protected] Manual 2 Contents 1 Introduction ....................................................................................................................... 3 2 Safety notes ....................................................................................................................... 3 3 Specifications .................................................................................................................... 4 3.1 General ...................................................................................................................................................... 4 3.2 Electrical (23 ± 5 °C) .................................................................................................................................. 4 4 System description ........................................................................................................... 5 5 pH / mV measurement and calibration procedure ........................................................... 6 5.1 pH measurement (manual temperature compensation) ............................................................................. 7 5.2 pH measurement (ATC, automatic temperature) ....................................................................................... 7 5.3 mV measurement ...................................................................................................................................... 7 5.4 pH calibration ............................................................................................................................................. 7 6 Other functions .......................................................................................................... 9 6.1 Data Hold ................................................................................................................................................... 9 6.2 Data record (MAX / MIN reading) .............................................................................................................. 9 6.3 LCD backlight on/off................................................................................................................................... 9 7 Datalogger ................................................................................................................. 9 7.1 Preparation before using the datalogger function ...................................................................................... 9 7.2 Auto datalogger (set sampling time ≧ 1 second) ...................................................................................... 9 7.3 Manual datalogger (set sampling time = 0 second) ................................................................................. 10 7.4 How to check the time information ........................................................................................................... 10 7.5 How to check the sampling time information ............................................................................................ 10 7.6 SD card data structure ............................................................................................................................. 11 8 Saving data from the SD card to the computer (EXCEL software) ............................... 11 9 Advanced settings ........................................................................................................... 12 9.1 SD memory card format ........................................................................................................................... 13 9.2 Set clock time (Year/Month/Date, Hour/Minute/Second).......................................................................... 13 9.3 Set sampling time (Hour/Minute/Second) ................................................................................................ 13 9.4 Auto power off management .................................................................................................................... 13 9.5 Set beeper sound on/off........................................................................................................................... 14 9.6 Decimal point of SD card setting .............................................................................................................. 14 9.7 Select the temperature unit °C or °F ........................................................................................................ 14 9.8 Set the pH manual temperature compensation value .............................................................................. 14 9.9 ESC ......................................................................................................................................................... 14 10 Power supply from optional mains adaptor .................................................................. 15 11 Battery replacement ........................................................................................................ 15 12 System reset .................................................................................................................... 15 13 RS-232 PC serial interface .............................................................................................. 15 14 Disposal ........................................................................................................................... 17 15 Contact ............................................................................................................................. 17 15.1 PCE Instruments UK ................................................................................................................................ 17 15.2 PCE Americas ......................................................................................................................................... 17 Manual 3 1 Introduction Thank you for purchasing a PCE-228 from PCE Instruments. * pH : 0 to 14.00 pH, mV ( ORP ) : ± 1999 mV. * pH measurement can select ATC or manual Temp. adj.. * Optional ATC probe for pH measurement. * pH measurement can make the auto calibration for pH 7, pH 4 and pH 10 or other value. * Real time SD memory card Datalogger, it Built-in Clock and Calendar, sampling time set from 1 sec to 8 hour 59 min. 59 sec. * Manual datalogger is available ( set the sampling time to 0 ), during execute the manual datalogger function, it can set the different position ( location ) No. ( position 1 to position 99 ). * Innovation and easy operation, computer is not need to setup extra software, after execute datalogger, just take away the SD card from the meter and plug in the SD card into the computer, it can down load the all the measured value with the time information ( year/month/date/hour/minute/second ) to the Excel directly, then user can make the further data or graphic analysis by themselves. * SD card capacity : 1 GB to 16 GB. * LCD with green light backlight, easy reading. * Can default auto power off or manual power off. * Data hold, record max. and min. reading. * Microcomputer circuit, high accuracy. * Power by UM3/AA ( 1.5 V ) x 6 batteries or DC 9V adapter. * RS232/USB PC COMPUTER interface. * Wide applications: water conditioning, aquariums, beverage, fish hatcheries, food processing, photography,laboratory, paper industry, plating industry, quality control, school & college, water conditioning. 2 Safety notes Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. There is no warranty of damages or injuries caused by non-observance of the manual. - The device may only be used in the approved temperature range. - The case should only be opened by qualified personnel of PCE Instruments. - The instrument should never be placed with the user interface facing an object (e.g. keyboard side on a table). - You must not make any technical changes to the device. - The appliance should only be cleaned with a damp cloth / use only pH-neutral cleaner. This user's handbook is published by PCE Instruments without any guarantee. We expressly point to our general guarantee terms which can be found in our general terms of business. If you have any questions please contact PCE Instruments. Manual 4 3 Specifications 3.1 General Measurement range 0.00 to 14.00 pH -1,999 to 0 to 1,999 mV (only with the optional Redox electrode) 0.0...65.0 °C (only the temperature sensor) Resolution 0.01 pH 1 mV 0.1°C Accuracy (at 20°C) ± (0.02 pH + 2 digits) ± (0.5 % + 2 digits) ±0.5°C Calibration Automatic three-point calibration Temperature compensation automatic from 0 to 65°C or manual between 0 and 100°C removing the temperature sensor Electrode pH PE-03 electrode, 1 meter cable and BNC plug temperature range: 0 ... 60 ºC Measurement rate adjustable from 1 second up to 8 hours 59 min 59 sec Display LCD display: 52 x 38 mm Memory SD card from 1 ... 16 GB (2 GB memory card included) Interface RS-232 Software optional Power supply 6 x 1.5 V AA batteries / mains adapter 9 V (optional) Operating conditions 0 to 50°C max. 80% r.h. Dimensions 177 x 68 x 45 mm Weight 490 g 3.2 Electrical (23 ± 5 °C) pH electrode Optional, any pH electrode with BNC connector Measurement pH 0 … 14 pH mV -1999 … 1999 mV Input impedance 10^12 ohm Temperature compensation for pH measurement Manual 0 … 100 °C, can be adjusted via button on front panel Automatic (ATC) with the optional temperature probe 0 … 65 °C pH calibration pH7, pH4 and pH10, 3-point calibration ensures the best linearity and accuracy