Swann Chematest 35 Manuals
Swann Chematest 35 Operator's manual (48 pages)
- Identifier: id-1463552
- Brand: Swann
- Device: Analytical Instruments
- Type: Operator's manual, PDF
- Key Aspects: Tips for Best Performance, Testing and Quality Assurance Processes
- UPD Date: 22.05.2026
- Source File: 1534889.pdf
- Pages: 48
- Description: Usage and setup manual for the Swann Chematest 35. It details troubleshooting tips and cleaning instructions, technical assistance, setup guidelines.
Key Pages and Contents:
-
A-96.730.120 / 080519
23 Calibration errors If the calibration is aborted with the message “Offset error!”: Make sure that the correct standard solution has been measured. The programmed value can be viewed under -
A-96.730.120 / 080519
Chematest 35 Menu Explanations 1.3 Calibration History Sensors Displays previous calibrations of the pH, redox and conductivity sensors. Each record includes the following data: Date, time Measured values depending on sensor: – pH: Offset and slope in mV – Redox: -
Recalling Stored Measurements
A-96.730.120 / 080519 19 5. Recalling Stored Measurements Data history Previous measurements can be displayed under the menu item -
A-96.730.120 / 080519
Chematest 35 Measuring Redox determination Remove the protection cap from the sensor, rinse the sensor tip with clean water and dip the sensor into the sample. Move the sen- sor gently several times before letting it stand. The displayed redox and temperature values are upda
Swann Chematest 35 Operator's manual (62 pages)
- Identifier: id-2245428
- Brand: Swann
- Device: Test Equipment
- Type: Operator's manual, PDF
- Key Aspects: Technical Details and Specifications, Future Product Updates, Glossary of Terms
- UPD Date: 26.03.2026
- Source File: 2042204.pdf
- Pages: 62
- Description: User instructions for the Swann Chematest 35. This guide includes detailed instructions for maintenance procedures, network configuration, system setup.
Key Pages and Contents:
-
A-96.730.121 / 160920
5 2. Product Description 2.1. Instrument Overview A B C D Sensor socket Charging socket Cuvette adapter Display E F G Keypad Cuvette cap Cuvette A B C D E F G -
A-96.730.121 / 160920
Chematest 35 Menu Explanations 3.4 Set Time Adjust date and time. 4 Settings 4.1 Sensors Photometer Enter the reference values of the verification cuvettes according to the enclosed calibration certificate. Range: 0.000–2.000 Electrode pH Filter time constant Used to damp -
A-96.730.121 / 160920
Chematest 35 Menu Explanations 4.3 Units Disinfectants Set the unit for disinfectants (all except ozone). Ozone Set the unit for ozone. Temperature Set the unit for temperature. Concentration TDS Set the unit for concentration calculated from conductivity. 4.4 Miscellaneous -
A-96.730.121 / 160920
23 6.2. Performing a Conductivity Measurement 1 Plug the sensor cable into the sensor socket. 2 Rinse the sensor tip with clean water. 3 Immerse the sensor at least four times in the sample until the vent holes [A] are below the water surface and lift
Chematest 35: Related Instructions from Other Manufacturers
-
Philips Signage Solutions BDL3250EL/00 Monitor Quick start manual
2 -
Vidao TV TV Quick start manual
2 -
Zanussi ZFT 56/2 R Refrigerator Instruction booklet
16 -
Beats Electronics SOLO HD Headphone Operation & user’s manual
17 -
Polypipe Under Floor Heating Systems Heating System Technical installation manual
28 -
Peavey XD3 Crossover Operating manual
11