Document Preview & Text Transcription
MANUAL SUPPLEMENT
TEKTRONIX
7B53A/7B53AN
DUAL TIME BASE
OPTION 5
INSTRUCTION MANUAL
Tektronix, Inc.
070-1471-00
P.O. Box 500
Beaverton, Oregon 97005
772
WARRANTY
This Tektronix product is warranted against defective materialsand
workmanship, under normal use, for a period of one year from date
of initial shipment. Tektronix will repair or replace, at its option,
those products determined to be defective within the warranty
period and returned, freight prepaid, to a Tektronix Service Center.
There is no implied warranty for fitness of purpose.
Please direct all requests for service or replacement parts to the
nearest Tektronix Service Center or Field Office; include the type or
part number of the product and its serial number.
Copyright ® 1972 by Tektronix, Inc. All rights reserved.
Contents of this publication may not be reproduced in any
form without the permission of Tektronix, Inc.
Products of Tektronix, Inc. and its subsidiaries are
covered by U.S. and foreign patents and/or pending
patents.
TEKTRONIX, TEK, SCOPE-MOBILE, TELEQUIPMENT,
and
are registered trademarks of Tektronix, inc.
Printed in U.S.A. Specification and price change
privileges are reserved.
7B53A/7B53AN OPTION 5
SPECIFICATION
General Information
The TV Sync Separator permits TEKTRONIX real-time
oscilloscopes to display composite video signals. The TV
Sync Separator clips video information from the incoming
video signal; then, it amplifies and separates the field or
vertical trigger pulses from the line or horizontal trigger
pulses. Line rate or field rate trigger pulses are provided
depending on the position of the front panel switch.
This manual insert describes the special features of the
7B53A/7B53AN OPTION 5 plug-in unit which has been
modified to enable triggering on composite video signals
through the use of a Sync Separator circuit. The EXT ÷ 10
and LINE positions of the Main Triggering Amplifier
SOURCE switch have been replaced by the TV FIELD and
TV LINE switch positions, allowing the sweeps to be
triggered by the output of the Sync Separator circuit at a
Field or Line Rate. The delayed sweep circuit has TV
LINE/EXT or INT/EXT SOURCE triggering capability,
depending on whether the connection is made to P903 or
P904.
Compatability
The TV Sync Separator can be used with 7400, 7500,
7600, 7700, and 7900-Series real time TEKTRONIX
oscilloscopes.
External Graticules
External graticules for the main frame are available. Use
the following information when ordering:
Main Frame
External Graticule
7403N-7603
CCIR Composite, Part No.
378-0684-04
NTSC Composite, Part No.
378-0684-05
Main Frame
External Graticule
7500,7700,7900 CCIR Composite, Part No.
378-0625-05
NTSC Composite, Part No.
378-0625-06
ELECTRICAL CHARACTERISTICS
Connector
Input or Output Signal
COMPOSITE
VIDEO IN (2
Major Divisions)
Needs 2 major divisions peak-to-
peak sync negative composite video
signal.
FIELD RATE
A group of one to six pulses, whose
minimum amplitude is 2 V nega
tive, shall re-occur at a field rate.
The width of each individual group
of pulses shall not exceed 3H.
LINE RATE
The line trigger pulses available
shall have a clean leading edge and a
minimum amplitude of 180 mV
negative.
SYSTEM CHARACTERISTICS
Compatibility
Compatible with V and H sync
signals of standard 405, 625, 819
Line/50 Hz, and 525 Line/60 Hz
broadcast systems; 405 to 1201
Line closed circuit systems.
Trigger Sensitivity
2 major divisions or more will
provide stable V or H triggering.
1
7B53A/7B53AN OPTION 5
OPERATING INSTRUCTIONS
Introduction
This section describes using the TV Sync Separator
portion of the time base plug-in unit.
Using the TV Sync Separator Plug-In
a. Connect a coaxial cable from the oscilloscope vertical
signal input connector to a composite video signal source of
such amplitude as to produce at least 2 major divisions of
vertical deflection.
Set the 7B53A/7B53AN OPTION 5 controls as follows:
Main Triggering Amplifier
SLOPE
MODE
COUPLING
SOURCE
AUTO
DC
TV FIELD
TIME/DIV
MAG
Main Time Base
2 ms
X1
b. Set the oscilloscope Main Triggering Amplifier
SOURCE switch to TV FIELD and the SLOPE switch to —.
c. Refer to the information under Obtaining a Display
in this section to obtain a display.
Adjusting the CLIPPING LEVEL Control (R914)
NOTE
If the input amplitude of the composite video
changes, it may be necessary to readjust the CLIP
PING LEVEL control (R914).
a. Connect the composite video as described under the
heading Using the TV Sync Separator Plug-In.
b. Turn the CLIPPING LEVEL control (R914) fully
clockwise.
c. Set the oscilloscope controls to obtain the desired
video display.
d. Slowly rotate the CLIPPING LEVEL control (R914)
counterclockwise until a point is found where the most
stable video display results.
TWO FIELD DISPLAY
To obtain a two field display, adjust the LEVEL control
to obtain a triggered display. The TIME/DIV VARIABLE
control may be adjusted to obtain a display of slightly less
than two fields.
LINE DISPLAYS
1. Variable Line Selector. To obtain Variable Line
Selector capabilities, the DLY'D TRIG control must be set
to the RUNS AFTER DLY TIME position. Pull the
TIME/DIV knob outward and rotate the knob to the
desired time/div position (10 µs). Rotate the DELAY TIME
MULT control to the desired portion of the waveform.
Push the TIME/DIV knob in and the desired portion of the
waveform will be displayed. The delayed sweep is free
running in this mode of operation.
2. Discrete Line Selector. For Discrete Line Selector
capability, place the Delayed Sweep Triggering SOURCE
switch in TV LINE position. Rotate the DLY'D TRIG
control out of the RUNS AFTER DLY TIME position and
set the control to obtain a triggered sweep. Rotate the
DELAY TIME MULT control until the desired line is
displayed. When rotating the DELAY TIME MULT control,
the display will jump from line to line.
3. Main Triggering Amplifier TV Line. Set the TIME/
DIV switch to 10 µs and check that the Main Triggering
Amplifier SOURCE switch is set to TV LINE. Adjust the
LEVEL control to obtain a stable display at the H rate.
Obtaining a Display
Install the TV Sync Separator Plug-In in the oscilloscope
as described under Using the TV Sync Separator. The
following instructions apply for the 7B53A/7B53AN OP
TION 5 plug-in unit.
DELAYED INTERNAL TRIGGER OPTION
The Delayed Sweep Triggering SOURCE selection may
be changed from TV LINE/EXT to INT/EXT or vice versa.
For INT/EXT triggering source capability, move the coaxial
connector from P903 to P904 and change the pushbutton
to read INT/EXT. The pushbutton is stored on the TV
Sync Separator board.
2