Topcon WT-100 Manuals

1 pdf manual(s) Topcon WT-100 for free download (Document Types: Instruction manual)

Topcon WT-100 Instruction manual Thumbnail

Topcon WT-100 Instruction manual [PDF] (2 pages)

  • Identifier: id-865322
  • Brand: Topcon
  • Device: Topcon WT-100 Touch terminals
  • Type: Instruction manual, PDF
  • Key Aspects: Troubleshooting Information, System Connectivity and Wiring Basics, Component Overview and Descriptions
  • UPD Date: 08.08.2026
  • Source File: 879250.pdf
  • Pages: 2
  • Description: Technical operation manual for the Topcon WT-100.
Pages Preview:
  • Topcon WT-100 Instruction manual preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
INSTRUCTION MANUAL WIRELESS TERMINAL WT-100 • Thank you for purchasing the TOPCON WT-100 Wireless terminal. • Please read this instruction manual carefully before using this product. • The specifications and general appearance of the instrument, and the content of this manual are subject to change without notice. • Some of the diagrams shown in this manual may be simplified for easier understanding. For the safe use of the product and prevention of injury to operators and other persons as well as prevention of property damage, items which should be observed are indicated by an exclamation point within a triangle used with WARNING and CAUTION statements in this instruction manual. The definitions of the indications are listed below. Be sure you understand them before reading the manual's main text. Definition of Indication Definition of Indication General � WARNING Power Supply � WARNING � CAUTION Wireless technology � WARNING Precautions • Confirm battery remaining level before operating. • Do not leave the instrument under strong sunlight for a long time. It may cause the instrument to malfunction. • When transporting the instrument, provide some protection to minimize the risk of shocks. Heavy shocks may cause the measurement to be faulty. • The instrument can not be submerged underwater. WT-100 is designed based on the International Standard IP54, therefore it is protected from the normal rainfall. • Remove the battery from the instrument when you would not use it for long period. If this instrument with the battery set in it is stored, the electrolyte may leak to cause a trouble. • Always clean the instrument after use. Wipe dry any moisture if the instrument becomes wet from rain. To clean the instrument, dust off well and then wipe clean with a soft cloth. • Never use thinner or benzine to remove dust on the surface of plastic parts. Use a clean cloth moistened with neutral detergent. • This product is for professional use only! The user is required to be a qualified surveyor or have a good knowledge of surveying, in order to understand the user and safety instructions, before operating, inspecting or adjusting. • Wear the required protectors (safety shoes, helmet, etc.) when operating. • The user of this product is expected to follow all operating instructions and make periodic checks (hardware only) of the product's performance. • The manufacturer, or its representatives, assumes no responsibility for results of faulty or intentional usage or misuse including any direct, indirect, consequential damage, or loss of profits. • The manufacturer, or its representatives, assumes no responsibility for consequential damage, or loss of profits due to any natural disaster, (earthquake, storms, floods etc.), fire, accident, or an act of a third party and/ or usage under unusual conditions. • The manufacturer, or its representatives, assumes no responsibility for any damage (change of data, loss of data, loss of profits, an interruption of business etc.) caused by use of the product or an unusable product. • The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits caused by usage different to that explained in the operator's manual. • The manufacturer, or its representatives, assumes no responsibility for damage caused by incorrect operation, or action resulting from connecting to other products. • Wireless terminal WT-100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 unit • Battery BT-66Q. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 pc. • Instruction manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 sheet • Battery Charger BC-30D, AC/DC Converter AD-14, AC cable • Tilt holder model-4 • Cable for connection to an external battery 1. Push down the battery cover lug to remove the battery cover. 2. As illustrated, load the battery BT-66Q with all contacts aligned. 3. Fit the lugs of the battery cover to the holes first. Then, push the battery cover lug until the cover is locked. �: • Attach a ferrite clamp filter (ZCAT2035-0930 or equivalent) to the power cable when using an external battery. Always wind the cable through the clamp filter in a single loop. Do not remove the ferrite clamp filter from the cable. Removal of the ferrite clamp filter may cause harmful interference and will void the user’s authority to operate this equipment. 1. Turn on the power. Press the power switch. Power LED lights. Make sure Wireless LED, System LED and Power LED light up on the display. �: • When an LED does not light or flash, check if the battery is securely inserted. 2. Wireless LAN connection �Connecting to Imaging Station IS series �Refer to the description about setup of wireless LAN in the IS series instruction manual. �Connecting to Data Collector FC-250 �Refer to the description about use of wireless LAN in the FC-250 instruction manual. �: The factory default settings of WT-100 are shown below. • SSID1: WT-100-W6���� • Encryption key: Not used. • Encryption scheme: Not used. • Wireless channel: Auto * "W6 ����" is the same as the serial number on the bottom of the instru- ment. In the following cases, it is necessary to initialize WT-100. • Can not connect even after checking how to connect or the settings of the product (IS series, FC-250, etc.) connected to WT-100. • When you change IP address of this instrument and subsequently forget the IP address. • When you want to change the settings back. �: • As all settings will be deleted upon initialization, please write down any necessary information beforehand. �When you want to carry out initialization, contact the Topcon head office or your local Topcon dealer. Wireless function Communication range: Approx. 300m (Applicable when IS2 is used. This may change depending on obstacles between the communicating instruments or ambient conditions.) Support format: IEEE802.11g, IEEE802.11b Channel: 11 (1 - 11ch) Band: 2.4GHz (2412 - 2462MHz) Network speed: IEEE802.11g: 54Mbps (Max.) IEEE802.11b: 11Mbps (Max.) Transfer mode: IEEE802.11g: Orthogonal Frequency Division Multiplexing (OFDM) IEEE802.11b: Direct sequence spread spectrum (DSSS) Access mode: Infrastructure mode Security: WEP (64/128bit) WPA-PSK (TKIP/AES) WPA2-PSK (TKIP/AES) Hidden SSID (Enable/Disable) Software function LAN setup mode: Fixed IP address (Manual setting) DHCP server (Enable/Disable) Routing function: Dynamic routing, Static routing PRECAUTIONS FOR SAFE OPERATION � WARNING Ignoring this indication and making an operation error could possibly result in death or serious injury to the operator. � CAUTION Ignoring this indication and making an operation error could possibly result in minor injury or property damage. � This symbol indicates items for which caution (hazard warnings inclusive) is urged. Specific details are printed in or near the symbol. � This symbol indicates items which are prohibited. Specific details are printed in or near the symbol. � This symbol indicates items which must always be performed. Specific details are printed in or near the symbol. PRECAUTIONS � Do not use the unit in areas exposed to high amounts of dust or ash, in areas where there is inadequate ventilation, or near combustible materials. An explo- sion could occur. � Do not perform disassembly or rebuilding. Fire, electric shock, or burns could result. � Do not short circuit. Heat or ignition could result. � Do not place articles such as clothing on the battery charger while charging bat- teries. Sparks could be induced, leading to fire. � Do not use voltage other than the specified power supply voltage. Fire or electri- cal shock could result. � Do not use batteries other than those designated. An explosion could occur, or abnormal heat generated, leading to fire. � Do not use damaged power cords, plugs or loose outlets. Fire or electric shock could result. � Use only the specified battery charger to recharge batteries. Other chargers may be of different voltage rating or polarity, causing sparking which could lead to fire or burns. � Do not use the battery or charger for any other equipment or purpose. Fire or burns caused by ignition could result. � Do not heat or throw batteries into fire. An explosion could occur, resulting in injury. � To prevent shorting of the battery in storage, apply insulating tape or equivalent to the terminals. Otherwise shorting could occur, resulting in fire or burns. � Do not use batteries or the battery charger if wet. Resultant shorting could lead to fire or burns. � Do not connect or disconnect power supply plugs with wet hands. Electric shock could result. � Do not touch liquid leaking from batteries. Harmful chemicals could cause burns or blisters. � Do not use within the vicinity of hospitals. Malfunction of medical equipment could result. � Use the instrument at a distance of at least 22 cm from anyone with a cardiac pacemaker. Otherwise, the pacemaker may be adversely affected by the electro- magnetic waves produced and cease to operate as normal. � Do not use onboard aircraft. The aircraft instrumentation may malfunction as a result. � Do not use within the vicinity of automatic doors, fire alarms and other devices with automatic controls as the electromagnetic waves produced may adversely affect operation resulting in an accident. EXCEPTIONS FROM RESPONSIBILITY STANDARD PACKAGE COMPONENTS OPTIONAL ACCESSORIES NOMENCLATURE AND FUNCTIONS Name LED Function or status Power switch Turns ON/OFF the power. Battery Low LED ON solid The battery power is low. Replace with a fully-charged battery. Wireless LED ON solid The wireless LAN function is valid. Flash Data are being sent/received. OFF The wireless LAN is not valid. System LED ON solid This instrument (WT-100) is operating normally. Flash Flashes when processing. OFF This instrument is not operating normally. Power LED ON solid The power is ON. OFF The power is OFF. INSTALLING AND REPLACING THE BATTERY Operation panel Display Connector for Product label: Battery Battery cover Power switch Battery LOW LED Mounting external battery Serial number cover lug hole (Small) Mounting hole (car battery etc.) Antenna for wireless LAN (DC12 V) Battery cover lug Lug BT-66Q Contact BASIC OPERATION Sometimes an error message indicating a communication error with DHCP server is displayed on the product connected to WT-100. In this case, net- work connection with WT-100 is normal. INITIALIZATION SPECIFICATIONS WT-100_E.fm 1 ページ 2011年2月24日 木曜日 午後1時36分

Similar Manuals in the Touch terminals Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
KoamTac KDC 500

KDC 500 (Barcode Reader ePDF Guide, #6GLOF9)

9 301 55 07-06-2026 view all manuals
PAX A920

PDF Guide (@4G9AMD), PAX A920 Payment Terminal (30-05-2026)

64 1444 361 30-05-2026 view all manuals
NEC SV-8100

NEC Server Installation manual (File: PDF, 26-05-2026)

86 549 132 26-05-2026 view all manuals
Newland NQ1000 MANTA

Touch terminals #8MSSOR

40 702 155 08-06-2026 view all manuals
Advanced MxPro4 Series

Advanced Control Panel Manual  (File: PDF, 28-03-2026)

40 519 109 28-03-2026 view all manuals
Motorola MTP850

MTP850 (Portable Radio ePDF User Guide, #5HK35K)

42 322 49 17-06-2026 view all manuals