4 pdf manual(s) Zooper Premier M+ for free download (Document Types: User manual, maintenance manual & log book, Installation manual, Log book & certificates)

Available Documents for Premier M+:

Zooper Premier M+ User manual, maintenance manual & log book Main Page Preview

User manual, maintenance manual & log book [PDF] (24 pages)

  • Brand: Zooper
  • Model: Premier M+
  • Format: PDF
  • Key Aspects: Glossary of Technical Terms, Technical Data and Parameters, FAQ Section for Common Queries
  • Updated: 01.09.2026
  • Source File: 145783.pdf
  • Pages: 24
  • Description: Operating and setup manual for the Zooper Premier M+.

Document Preview & Text Transcription

. USER MANUAL , MAINTENANCE GUIDE & LOG BOOK PREMIER AD USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-106 PAGE 2 Issue: 1.02 Authorised: GH Date: 15/03/2004 What to do if the Fire Alarm Panel shows an Alarm (Red LED) Write down the LCD reading and which LEDs are lit (either in the log book, or on a piece of paper for transferring to the log book later) Follow the building procedures for fire alarm activation. When the building has been evacuated, the sounders can be silenced by turning the key to the on position and pressing the Start/Stop Sounder button, then pressing the Silence Tone button. (Note that the sounders may take up to 8 seconds to stop) If there is no sign of fire, investigate the area that reported the fire CAREFULLY. Check for a detector or a call point with its RED LED lit. If a detector caused the alarm, look for any innocent phenomena that could have activated it (Steam, cooking food, exhaust smoke, excessive dust etc can all activate a smoke detector.). If anything is found, try to clear the room by opening a window. If a fire is discovered, either tackle it with fire extinguishers if suitably trained, or call the fire brigade. To reset the panel press the reset button. If the panel goes back into alarm, silence the sounders and call the engineer. What to do if the Fire Alarm Panel shows a Fault (Yellow LED) Write down the LCD reading and which LEDs are lit (either in the log book, or on a piece of paper for transferring to the log book later) If the supply fault LED is lit, check if there is a power cut to the building. Check that the mains supply to the fire alarm has not been turned off. If the Prealarm LED is on, this could be either a detector that needs servicing, or the start of a fire (or other phenomena that can activate the detector). Investigate the indicated location and take appropriate action. All other fault indications will need the service engineer’s attention. Call the engineer as soon as possible. Note that when the alarm is in a fault condition, the majority of the system will still function correctly. Extra vigilance should be paid in the area with the fault. The alarm may not be operational in this area. The panel`s internal buzzer can be silenced by turning the key to the on position and pressing the Silence Tone button. If the fault comes and goes, the panel will buzz every time the fault happens. If this is not acceptable you may be able to disable the zone that has the fault. (see page 11) PREMIER AD USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-106 PAGE 3 Issue: 1.02 Authorised: GH Date: 15/03/2004 CONTENTS 1. FIRE ALARM CONTROL PANEL SAFETY ISSUES……………………………………… 3 How to use this Fire Alarm Panel safely 2. THE PURPOSE OF A FIRE ALARM SYSTEM……………………………………………… 3 Introduction to fire alarms 3. USER RESPONSIBILITIES & MAINTAINENCE OF THE FIRE ALARM SYSTEM, INCLUDING THE FACP & ITS INTEGRAL PSE …………………………………………………………………… 4 What the end users responsibility is, including daily, weekly, quarterly & annual checks 4. PANEL INDICATIONS & CONTROLS …………………………..………………………….. 5 A list of indicator LEDs & Control Buttons on the Premier AD Fire Alarm Panel 4.1 INDICATIONS 4.2 CONTROLS 4.3 ACCESS LEVELS 4.4 CHECKING THE PANELS INDICATION LEDS 4.5 WHAT THE LEDS MEAN 5. THE FIRE CONDITION ………………………………………………………………………… 6 5.1 HOW THE PREMIER AD INDICATES AN ALARM 5.2 TO TURN OFF THE ALARM SOUNDERS 5.3 A SECOND ALARM SIGNAL FROM A NEW DETECTION ZONE 5.4 TURNING ON THE ALARM SOUNDERS FROM THE FACP (I.E. EVACUATE ). 5.5 RESETTING THE PANEL 6. THE FAULT CONDITIONS …………………………………………………………………. 7 6.1 DIFFERENT TYPES OF FAULT 6.2 WHAT TO DO IF A FAULT CONDITION OCCURS 6.3 OTHER LED INDICATIONS 7. DISABLEMENTS …………………………………..……………………………………… 10 7.1 REASONS FOR DISABLING CERTAIN PARTS OF A FIRE ALARM SYSTEM 7.2 TO DISABLE A ZONE AND/OR EXTERNAL SOUNDER 7.3 TO ENABLE A ZONE AND/OR EXTERNAL SOUNDER 8. SOUNDER DELAYS ON THE PREMIER AD ………………………………………………. 11 8.1 OVERRIDING A DELAY IN THE EVENT OF A GENUINE FIRE ALARM 8.2 RESET THE SYSTEM IN THE EVENT OF A FALSE ALARM 9. SYSTEM DESCRIPTION ………………………………………………………….………... 12 Lists system comments 10. FIRE ALARM LOG BOOK………………………………………………………………….. 15 A place for you to record details of events such as fires, false alarms, call outs, etc. 11 COMMISSIONING THE SYSTEM, INCLUDING P.S.E.………………………………… 17 12 INSTALLATION & COMMISSIONING CERTIFICATE ………………………………… 18
Zooper Premier M+ Installation manual Main Page Preview

Installation manual [PDF] (22 pages)

  • Brand: Zooper
  • Model: Premier M+
  • Format: PDF
  • Key Aspects: Manufacturer Contact and Support Data, Component Longevity Optimization, Cleaning and Sanitization Methods
  • Updated: 30.07.2026
  • Source File: 145805.pdf
  • Pages: 22
  • Description: Professional operation guide for the Zooper Premier M+.

Document Preview & Text Transcription

M+48 INSTALLATION MANUAL PREMIER M PLUS 48 INSTALLATION MANUAL. Approved Document No: GLT.MAN-120 PAGE 2 Issue : 1.2 Authorised: GH Date: 2/11/2007 PREMIER M 48 OVERVIEW. The Premier M plus 48 is the latest large size conventional panel from Zeta Alarm Systems. Its Features include: - • Designed to EN54 Parts 2 & 4. • It is available in sizes from 24 to 48 zones in 4 zone increments. • Automatically uses diode bases for line continuity. • Four common sounder circuits (400mA Each). • Serial Repeater Output. • Fire & Fault Relays (SELV). • F.A.R.E. Output (which can be disabled). • Auxiliary supply (29 Volts, 250 mA). • Zone & Sounder Disablement facility. • One man test mode. • Sounder delay facility. • 3 amp power supply. • Is a low cost alternative to the existing Premier L panel . PREMIER M PLUS 48 INSTALLATION MANUAL. Approved Document No: GLT.MAN-120 PAGE 3 Issue : 1.2 Authorised: GH Date: 2/11/2007 CONTENTS 1. INTRODUCTION…….…………………………………………………………… 4 1.1 HANDLING THE PCBS 1.2 USING THIS MANUAL 1.3 ABOUT THE PREMIER M PLUS 48 FACP & INTEGRAL PSE 1.4 DESIGNING THE SYSTEM 1.5 EQUIPMENT GUARANTEE 2. FIRST FIX GUIDELINES…………………………………………………………. 5 2.1 RECOMMENDED CABLE TYPES AND THEIR LIMITATIONS 2.2 MAINS WIRING RECOMMENDATIONS 2.3 DETECTOR CIRCUIT WIRING DIAGRAM 2.4 SOUNDER CIRCUIT WIRING DIAGRAM 2.5 AUXILIARY OUTPUT WIRING 3. MOUNTING THE FIRE ALARM PANEL…………………………………..…. 8 3.1 PLANNING CABLE ENTRY 3.2 FIXING THE BACKBOX TO THE WALL 4. CONNECTING MAINS & BATTERY POWER………………………………. 9 4.1 CONNECTING MAINS POWER 4.2 CONNECTING THE BATTERIES 5. FIELD DEVICE TERMINATION…..……………………………………………………. 10 5.1 TERMINATING THE DETECTION AND ALARM (SOUNDER) CIRCUITS 5.2 AUXILIARY INPUT AND OUTPUT TERMINATIONS 6. CONFIGURING THE PANEL……………………………………….…………..…. 11 6.1 SOUNDER ACTIVATION DELAY 6.2.1 DECIDING TO SET A DELAY 6.2.2 TO SET A DELAY 6.2.3 DELAY INDICATION AND OVERRIDE 6.2 USING SOUNDER DELAY TO COMMON TIMER 7. ZONE DISABLEMENT…………………………………………………………. 13 7.1 WHY USE ZONE DISABLEMENT 7.2 TO PROGRAM A ZONE (OR SOUNDERS) AS DISABLED 8. ZONE TEST………………………………………………………………………. 14 8.1 WHY USE ZONE TEST 8.2 TO PROGRAM ZONE IN TEST 9. GENERAL FAULT FINDING...…………………………………………………. 15 9.1 ZONE FAULTS 9.2 SYSTEM FAULT 9.3 SUPPLY FAULTS 9.4 EARTH FAULTS 9.5 SOUNDER FAULTS 9.6 REPEATER FAULTS 9.7 F.A.R.E. FAULTS 10. STANDBY BATTERY CALCULATION GUIDE………………………..……. 17 11. PCB TERMINATION CONNECTIONS……….………………………………. 18 11.1 CONNECTIONS 11.2 FUSES 12. CONTROL PANEL ELECTRICAL SPECIFICATIONS..……………………. 19 12.1 ENCLOSURE SPECIFICATIONS 12.2 ELECTRICAL SPECIFICATIONS 1.INTRODUCTION PREMIER M PLUS 48 INSTALLATION MANUAL. Approved Document No: GLT.MAN-120 PAGE 4 Issue : 1.2 Authorised: GH Date: 2/11/2007 THIS FIRE ALARM CONTROL PANEL IS CLASS 1 EQUIPMENT AND MUST BE EARTHED This equipment must be installed and maintained by a qualified and technically experienced person. 1.1 HANDLING THE PCBS If the PCBs are to be removed to ease fitting the enclosure and cables, care must be taken to avoid damage by static. The best method is to wear an earth strap, but touching any earth point (e.g. building plumbing) will help to discharge any static. Hold PCBs by their sides, avoiding contact with any components. Always handle PCBs by their sides and avoid touching the legs of any components. Keep the PCBs away from damp dirty areas, e.g. in a small cardboard box. 1.2 USING THIS MANUAL This manual explains, in a step-by-step manner, the procedure for the installation of the Premier M 48 Range of Fire Alarm Control Panels. For full operational and maintenance information, please refer to document GLT.MAN-121 (USER MANUAL, MAINTENANCE GUIDE & LOG BOOK). It also contains a System set-up table, and Design, Installation and Commissioning Certificates, that must be completed by the appropriate engineers prior to system handover. Unlike the User Manual, this Installation Manual must not be left accessible to the User. 1.3 ABOUT THE PREMIER M 48 ALARM CONTROL PANEL & INTEGRAL PSE 1.4 DESIGNING THE SYSTEM This manual is not designed to teach Fire Alarm System design. It is assumed that the installer has an understanding of Fire Alarm System components and their use. We strongly recommend consultation with a suitably qualified, competent person regarding the design of the Fire Alarm System. The System must be commissioned and serviced in accordance with our instructions and the relevant National Standards. Contact the Fire Officer concerned with the property at an early stage in case he has any special requirements. If in doubt, read BS 5839: Pt 1: 2002 “Fire Detection and Alarm Systems for buildings (Code of Practice for System Design, Installation and Servicing)” available from the BSI, or at your local reference library. 1.5 EQUIPMENT GUARANTEE If this equipment is not fitted and commissioned according to our guidelines, and the relevant National Standards, by an approved and competent person or organisation, the warrantee may become void. • The PREMIER M PLUS Fire alarm control panel is available in 24 & 48 Zone sizes. • It has 4 common sounder output circuits each capable of supplying 400mA. • It has a 250mA auxiliary 30V output • It has a set of fire relay contacts (voltage free) rated at 1A SELV. • It has a set of fault relay contacts (voltage free) rated at 1A SELV. (normally energised) • It has the ability to disable any zone, or the common sounder circuits. • It has a one man test mode, which resets the zone in test after 4 seconds.(EN54 option with requirements) • It has a sounder delay facility (0-9 minutes in 1 minute steps). (EN54 option with requirements) • It has a maximum battery capacity of 7 Ah. • It has an in built capability of operating with Diode bases (for line continuity on head removal). • It will operate in ambient temperatures of –5 to 40 oC • It will operate in a relative humidity of up to 93% (non condensing) • It will withstand vibrations between 5 & 150 Hz • It has a maximum capacity of 32 devices per zone (But for locating potential future problems or events, we would usually recommend a practical maximum of 20 devices per zone) • The PSE is linear, with a 3.0A output at system voltage (18-32V) • The charger & battery are both fused at 3.15A (TD) • The PSE will draw a maximum of 25uA from the battery in the event of mains failure. (The FACP will continue to take around 150mA) • The FACP & PSE should be maintained as described in section 3 of the User Manual, Maintenance Guide & Log Book.
Zooper Premier M+ Installation manual Main Page Preview

Installation manual [PDF] (22 pages)

  • Brand: Zooper
  • Model: Premier M+
  • Format: PDF
  • Key Aspects: Cleaning and Sanitization Methods, Safety Recommendations and Warnings, Additional Modules and Accessories Guide
  • Updated: 08.08.2026
  • Source File: 145808.pdf
  • Pages: 22
  • Description: Professional user manual for the Zooper Premier M+.

Document Preview & Text Transcription

PREMIER M PLUS INSTALLATION MANUAL Approved Document No: GLT.MAN-111 Issue : 2.8 Author: NJ Date: 23/07/2012 8-24 ZONE CONVENTIONAL FIRE ALARM PANEL INSTALLATION MANUAL PREMIER M PLUS INSTALLATION MANUAL Approved Document No: GLT.MAN-111 PAGE 1 Issue : 2.8 Author: NJ Date: 23/07/2012 PREMIER M PLUS OVERVIEW The Premier M plus is a medium size conventional panel from Zeta Alarm Systems. Its Features include:-  Designed to EN54 Parts 2 & 4.  It is available in 8 ,16 or 24 zones sizes.  Automatically uses diode bases for line continuity.  Four common sounder circuits (400mA Each).  Serial Repeater Output.  Fire & Fault Relays (SELV).  Fire Alarm Routing Equipment (F.A.R.E.) Output (which can be disabled).  Auxiliary supply (29 Volts, 250 mA).  Zone & Sounder Disablement facility.  Test mode.  Sounder delay facility.  5 amp power supply. PREMIER M PLUS INSTALLATION MANUAL Approved Document No: GLT.MAN-111 PAGE 2 Issue : 2.8 Author: NJ Date: 23/07/2012 Contents PREMIER M PLUS OVERVIEW ...................................................................................................................................................................1 1.SAFETY INFORMATION ..........................................................................................................................................................................3 1.1 INSTALLATION INFORMATION ......................................................................................................................................................3 1.2 BATTERY INFORMATION ...............................................................................................................................................................3 1.3 PRODUCT DISPOSAL AT THE END OF ITS WORKING LIFE ..............................................................................................................3 2. PRODUCT DESIGN INFORMATION ........................................................................................................................................................4 2.1 FIRE ALARM CONTROL SECTION ...................................................................................................................................................4 2.2 POWER SUPPLY SECTION ..............................................................................................................................................................4 2.3 ENVIRONMENTAL .........................................................................................................................................................................4 2.4 DESIGNING THE SYSTEM ...............................................................................................................................................................4 2.5 EQUIPMENT GUARANTEE .............................................................................................................................................................4 3. FIRST FIX ..............................................................................................................................................................................................5 3.1 RECOMMENDED CABLE TYPES AND THEIR LIMITATIONS .............................................................................................................5 3.2 MAINS WIRING RECOMMENDATIONS ..........................................................................................................................................5 3.3 DETECTION CIRCUIT WIRING DIAGRAM .......................................................................................................................................5 3.4 SOUNDER CIRCUIT WIRING DIAGRAM .........................................................................................................................................6 3.5 AUXILIARY OUTPUT WIRING.........................................................................................................................................................6 4. MOUNTING THE FIRE ALARM PANEL ...................................................................................................................................................8 4.1 PLANNING CABLE ENTRY ..............................................................................................................................................................8 4.2 FIXING THE BACK BOX TO THE WALL ............................................................................................................................................8 5. CONNECTING MAINS & BATTERY POWER ............................................................................................................................................9 5.1 CONNECTING THE MAINS POWER ................................................................................................................................................9 5.2 CONNECTING THE BATTERIES .......................................................................................................................................................9 6. FIELD DEVICE TERMINATION ..............................................................................................................................................................10 6.1 TERMINATING THE DETECTION AND ALARM (SOUNDER) CIRCUITS. ..........................................................................................10 6.2 AUXILIARY INPUT AND OUTPUT TERMINATIONS .......................................................................................................................10 7. CONFIGURING THE PANEL .................................................................................................................................................................11 7.1 SOUNDER ACTIVATION DELAY ....................................................................................................................................................11 8. ZONE DISABLEMENT ..........................................................................................................................................................................11 8.1 WHY USE ZONE DISABLEMENT ...................................................................................................................................................11 8.2 TO PROGRAMME ZONE (OR SOUNDERS) AS DISABLED ..............................................................................................................12 9. ZONE TEST .........................................................................................................................................................................................13 9.1 WHY USE ZONE TEST ..................................................................................................................................................................13 9.2 TO PROGRAMME ZONE IN TEST .................................................................................................................................................13 10. GENERAL FAULT FINDING .................................................................................................................................................................14 10.1 ZONE FAULTS ............................................................................................................................................................................14 10.2 SYSTEM FAULT ..........................................................................................................................................................................14 10.3 SUPPLY FAULTS..........................................................................................................................................................................14 10.4 EARTH FAULTS...........................................................................................................................................................................15 10.5 SOUNDER FAULTS .....................................................................................................................................................................15 10.6 REPEATER FAULTS .....................................................................................................................................................................15 10.7 F.A.R.E. FAULTS .........................................................................................................................................................................15 11. STANDBY BATTERY CALCULATION ....................................................................................................................................................16 12. PCB TERMINATION CONNECTIONS .................................................................................................................................................. 17 12.1 CONTROL PANEL CONNECTIONS .............................................................................................................................................. 17 12.2 CONTROL PANEL CONNECTIONS .............................................................................................................................................. 17 12.3 CONTROL PANEL FUSES ............................................................................................................................................................ 17 12.4 POWER SUPPLY PCB ..................................................................................................................................................................18 12.5 POWER SUPPLY CONNECTIONS ................................................................................................................................................19 12.6 POWER SUPPLY FUSES ..............................................................................................................................................................19 13. PANEL SPECIFICATIONS ....................................................................................................................................................................20 13.1 ENCLOSURE SPECIFICATIONS ....................................................................................................................................................20 13.2 ELECTRICAL SPECIFICATIONS ....................................................................................................................................................20
Zooper Premier M+ Log book & certificates Main Page Preview

Log book & certificates [PDF] (16 pages)

  • Brand: Zooper
  • Model: Premier M+
  • Format: PDF
  • Key Aspects: Troubleshooting Information, Routine Functionality Testing, Regulatory Compliance and Standards
  • Updated: 09.04.2026
  • Source File: 145811.pdf
  • Pages: 16
  • Description: Comprehensive guide for the Zooper Premier M+.

Document Preview & Text Transcription

PREMIER M PLUS USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-113 Issue: 2.2 Author: NRPJ Date: 24/7/2012 8-24 ZONE CONVENTIONAL FIRE ALARM PANEL LOG BOOK & CERTIFICATES PREMIER M PLUS USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-113 PAGE 1 Issue: 2.2 Author: NRPJ Date: 24/7/2012 FIRE ZONE INFORMATION ZONE NO. ZONE DESCRIPTION A brief description of all the rooms and areas contained in each zone. QTY SNDR QTY MCP QTY HEADS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 SOUNDER CIRCUIT INFORMATION SOUNDER CIRCUIT SOUNDER CIRCUIT DESCRIPTION A brief description of all the rooms and areas contained in each circuit. QTY SNDR QTY BELLS CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 ANY OTHER INFORMATION ABOUT THE SOUNDER CIRCUITS PREMIER M PLUS USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-113 PAGE 2 Issue: 2.2 Author: NRPJ Date: 24/7/2012 OUTPUT ROUTING INFORMATION TYPE OF OUTPUT CONNECTED WHAT HAPPENS WHEN ACTIVATED FIRE RELAY YES/NO FAULT RELAY YES/NO F.A.R.E. OUTPUT YES/NO ADDITIONAL INFORMATION THE ABOVE INFORMATION WAS COMPLETED BY: NAME COMPANY POSITION DATE PREMIER M PLUS USER MANUAL, MAINTENANCE GUIDE & LOG BOOK Approved Document No: GLT.MAN-113 PAGE 3 Issue: 2.2 Author: NRPJ Date: 24/7/2012 It is recommended that this LOG BOOK be maintained by the responsible person(s) on site, who should ensure every event is properly recorded (including fire alarm conditions, failures, tests, temporary disconnections, disablements, enablements, dates of installing engineers’ visits together with a note of any outstanding work or panel conditions). This LOG BOOK must be available for inspection at all times. You can photocopy this log book now to provide extra pages when this book is full. Company:_______________________________________________________________________ Site Address:____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ System Designed By: ______________________________________________________________ System Installed By: ______________________________________________________________ System Commissioned By: _________________________________________________________ System Maintained By: ____________________________________________________________ Contract No:_____________________________________________________________________ Contract Valid Until: ______________________________________________________________ For Service (normal hours Mon-Fri) Tel:_______________________________________________ For Service (other times) Tel:_______________________________________________________ Responsible Person(s) on Site: ______________________________________________________ BS5839-1:2002+A2:2008 recommends that fire alarm events should be subdivided & recorded on separate sheets in the log book. The event categories are: Maintenance work – to be completed by any engineer undertaking any work on the system. False Alarms – any alarm on the system not caused by a genuine fire. This includes:  ENVIRONMENTAL  FIRE –LIKE PHENOMENA  INAPROPRIATE ACTION  ACCIDENTAL DAMAGE  MALICIOUS ACTION  GENUINE BELIEF  EQUIPMENT FALSE ALARM All other events: This would include all genuine alarms, and any faults that occur on the system.