Zooper ZIU Manuals

1 pdf manual(s) Zooper ZIU for free download (Document Types: Operation & user’s manual)

Document Preview & Text Transcription

DOC: GLT.MAN-125 ISSUE: 1 www.gltexports.com DATE: 14/4/08 ALARM SYSTEMS ADDRESSABLE INTERFACE UNITS ZIU – ADDRESSABLE INPUT UNIT 5 0 4 9 6 1 3 8 7 2 5 0 4 9 6 1 3 8 7 2 5 0 4 9 6 1 3 8 7 2 D Connections & Address Setting The ZIU has the following connections:- Loop IN + Loop IN – (2 connections) Loop OUT + Loop out – MON I/P (2 connections) Normally the loop cables will be connected one pair of +/- to the IN terminals (use either IN- terminal), and the other pair of cables to the OUT terminals. If the isolator needs to be PERMANENTLY bypassed, connect the – OUT to the spare –IN terminal. To temporarily bypass the isolator (eg for a DVM cable continuity check), fit a shorting link to position J1. The ZIU is now addressed by 3 rotary switches, one for 100`s one for 10`s, one for units. Select an address between 1 & 126. (The picture shows 037) PCB Identification The same PCB is used for The ZIU (input only), ZIOU (Input with volt free relay output), and ZSCC (sounder circuit controller). Each PCB will have an Identification mark (tick or “X”) to show which model it is. Description The Zeta addressable Input Unit (ZIU) is used to interface external equipment which has a volt free NORMALLY OPEN relay output to any Zeta Analogue Addressable fire alarm system. The input is monitored with a 47k end of line resistor. The unit has a built in loop short circuit isolator to help keep the unit operational in the event of a problem on the addressable loop wiring. It has 3 indication LEDs on the front of the unit. One for Alarm, one for local fault and one for addressable loop fault (Isolator active). DOC: GLT.MAN-125 ISSUE: 1 www.gltexports.com DATE: 14/4/08 ALARM SYSTEMS ADDRESSABLE INTERFACE UNITS ZIU – ADDRESSABLE INPUT UNIT Technical Data OPERATING VOLTAGE 17 – 33V DC QUIESCENT CURRENT 900uA ALARM CURRENT 2.9mA FAULT CURRENT 2.8mA ISOLATING CURRENT 7.3mA INPUT END OF LINE 47K DEVICE NORMAL RESISTANCE (RETURN VALUE 16) 10K to 75K DEVICE OPEN CCT FAULT RESISTANCE (RETURN VALUE 4) 85K to open circuit DEVICE ALARM RESISTANCE (RETURN VALUE 64) 0K to 5K OPERATING TEMPERATURE 0oC to 50oC MAX HUMIDITY 95% RH Non Condensing IP RATING IP43 SIZE 127 x 88 x 59 mm WEIGHT 220g Short Circuit Isolator Specification MAXIMUM LINE VOLTAGE 33V DC MINIMUM LINE VOLTAGE (NON ISOLATING) 17V DC MAXIMUM RATED CONTINUOUS CURRENT 1 Amp MAXIMUM RATED SWITCHING CURRENT 3 Amp MAXIMUM LEAKAGE CURRENT (ISOLATING) 0.7 mA MAXIMUM SERIES IMPEDENCE 47K ISOLATION VOLTAGE 15.6V +/- 0.5V ISOLATION RESPONSE TIME 25 us to 300 us RECONNECTION VOLTAGE 18.5V +/- 0.5V RECONNECTION TIME UP TO 2 SEC Troubleshooting DEVICE NOT SEEN BY PANEL CHECK ADDRESS SETTING CHECK WIRING TO DEVICE (FOR CONTINUITY & POLARITY) CHECK FOR LOOP VOLTAGE AT DEVICE + & - TERMINALS DEVICE REPORTS A FAULT (ANALOGUE VALUE 4) CHECK WIRING FROM DEVICE TO MONITORED CONTACT CHECK FOR CORRECT END OF LINE DEVICE REPORTS AN ALARM (ANALOGUE VALUE 64) CHECK IF MONITORED CONTACTS ARE OPERATING CORECTLY CHECK FOR SHORT CIRCUIT ON WIRING CHECK THAT A NORMALLY CLOSED CONTACT IS NOT USED ANALOGUE VALUE UNSTABLE CHECK FOR DOUBLE ADDRESS FAULTS CHECK FOR LOOP DATA CORRUPTION WITH LOOP TEST TOOL LOOP FAULT (ISOLATING) LED ON CHECK FOR SHORT CIRCUIT ON LOOP CHECK FOR WRONG POLARITY CONNECTION TO LOOP DEVICES CHECK FOR TOO MANY DEVICES BETWEEN ISOLATORS Protocol usage The ZIU addressable interface unit has no panel controllable outputs. All it`s indication LEDs are under its own control. In the event of an alarm, it will set input bit 0 to an active condition, as well as setting it’s analogue value to 64 to indicate it’s activation. Other information Like all electronic equipment, at the end of it`s working life this unit should not be disposed of in a refuse bin. It should be taken to a local reprocessing site as per the guidelines of the WEEE directive, for correct disposal.